Connecting to the Sustainable

Future with 5G Wireless and M2M


Gateway Technology

Presented by
Paul O‘Shaughnessy, Channel Sales Manager, Industrial-IoT Group, Advantech Europe
John Tuersley , Global Open Labs Manager, Vodafone
Markus Ahonen, Managing Director NDC Networks & Head of Special Purpose
Networks Cinia, NDC Networks Ltd & Cinia Ltd
Soumen Bhowmik , Assistant General Manager - Projects, Mitsubishi India
Securely deploying large-scale
cellular SCADA connectivity
with Energy DSOs
Markus Ahonen
Managing Director, NDC Networks Ltd.
Head of Special Purpose Networks, Cinia Ltd.
Large-scale cellular connectivity Backup solution
for critical sites

Azure,
Device AWS
management

Firewall & VPN


Data center 1

Firewall & VPN Cellular 500-10000 x


Data center 2 networks IoT Gateway

Network
monitoring,
NOC/SOC
Grid trends

• Automation increasing everywhere in grids


• Volumes up, prices down
• IT departments taking control of IoT projects
• Result:
• Huge cloud of edge devices
• Build & operate with low OPEX per node
• Must be secure
Lessons learned: Security & deployment

• Cybersecurity
• Seek network simplicity to improve reliability
• Firewall as VPN is the only viable VPN solution
• Isolating from the internet is not a strategy; defence-in-depth is mandatory
• Cloud security is critical for DSOs
• Scrutinize the minute details of how your vendor establishes chain of trust in zero touch
• Deployment
• You need Design Thinking to create fluid operations (physical & digital)
• Device management automation & zero touch is the key tool

5 31.3.2021
Automation Requirement of Typical SCADA Based Water
Treatment & Distribution Project

01 02 03 04 05 06 07

It is Passed Chemical may be added The flocs settle out of The Water is The pH of the The Water
Water taken
through a to the water to make the water and water is disinfected using UV / Water may be is Stored,
from a River
Screen to smaller particles bind filtered through sand by adding chlorine to adjusted and ready to be
or Ground
Remove together to form large and gravel to remove kill any bugs which fluoride is piped to
Water Source
Large items Particles called flocs any remaining Particles might cause illness added consumers

Specification Requirement:-

1. Redundant SCADA Server with Historian -Mitsubishi direct offering


2. Redundant Hot-Standby PLC System for WTP(Water Treatment plant) -Mitsubishi direct offering
3. Standalone PLC and HMI System for RWPH( Raw Water Pumping Station) -Mitsubishi direct offering
4. Redundant PLC System for CWPH(Clear Water pump House) -Mitsubishi direct 0ffering
5. RTU on GPRS Based communication over DNP3 Protocol for OHSR(Over head Service Reservoir)-210nos
- Offering with help / product support from Advantech
1. RTU on GPRS Based communication over DNP3 Protocol for MBR(Membrane Bio Reactor Technology)-04nos
- Offering with help / product support from Advantech
7
© Mitsubishi Electric Corporation
Mitsubishi Electric - Process Automation Business

Objectives:

• Process Automation Dept. in India formed in the Year -2014.


• Approval from various Govt. Sectors applied and successfully achieved.
• Tie up with various EPC’s for the supply of Automation System
Offering:

Turnkey solutions: STIC (Supply, Test, Install & Commission)

 Concept, Design, Engineering , Manufacturing and Commissioning


 Preparation of functional design specifications
 Design, Configuration & Programming of PLC/DCS System
 Design & Development SCADA & Interface configurations.
 Electrical & Control Panels – Engineering, Assembly & Testing
 Preparation of Detailed Drawings & Documentation.
 Offer Factory Acceptance Tests
 Installation , Commissioning & Site Acceptance Tests
 Training , Maintenance Procedures for System
 O&M Support

8
© Mitsubishi Electric Corporation
System Configuration
FIELD IO SOLUTION ON DNP3 BY
ADVANTECH (ADAM 3600) 7" HMI 7" HMI

(8-DI, 4-DO, 8-AI


48” SCREEN

DNP3 RTU
HISTORIAN CUM OPERATOR
SCADA Server STATION
Dot Matrix FIELD IO FIELD IO
printer A3 color OVER HEAD SERVICE RESERVOIR OVER HEAD SERVICE RESERVOIR
inkjet Printer (OHSR-01) (OHSR-210)
STATIC IP
210 NOS

ETHERNET SW-1 ETHERNET NETWORK (10/100 Mbps)

ETHERNET SW-2 7" HMI


HOT REDU. CPU

RED. LINK

MELSECNET NETWORK(Fibre Optic) FIELD IO

MBR

04 NOS
(MBR-01)

GPRS
Modem 10" HMI 10" HMI 10" HMI
STANDALONE
PLC SYSTEM

10" HMI 7" HMI

FIELD IO FIELD IO FIELD IO FIELD IO

RWPH WTP FILTER FILTER CWPH


(WATER TREATMENT (CLEAR WATER
(RAW WATER PUMP HOUSE)
PLANT) BED-1 BED-10 PUMP HOUSE)
FIELD IO

MBR
(MBR-04)
10 NOS 9
© Mitsubishi Electric Corporation
Co-Creating the Future
of the IoT World