T r a n s f o r m i n g T e c h n o l o g i e s , L L C

O u t s t a n d i n g A l t e r n a t i v e s i n S t a t i c C o n t r o l

Ohm Metrics™
Continuous Workstation Monitors
Model CM410

Instruction Manual
CM410 Installation Diagrams

1) Mount monitor under bench area (use included screws or


Velcro).

2) Attach the “Bench” cord (smaller plug) to the back of monitor


and attach the banana plug into the common point ground.

3) Plug AC power supply to monitor and grounded 110v outlet


(monitor grounded through AC Adapter). Bench light should
be green.

4) Operator LED should be RED and alarm will sound 1 long


beep.

5) With wrist strap worn correctly while plugged into monitor,


LED will go from RED to GREEN when in use indicating
grounding is functioning.

Power

Common Point

Ground
Work Station Mat

CM410 With
Wrist Strap
Mounting Bracket
Operation
Monitoring begins when the coiled cord of the wrist strap is
plugged into the monitor or remote jack. The status of a wrist
strap resistance is indicated by a the bicolor LED and audi-
ble Alarm:

Stand-by indication.
If the wrist strap is removed or not being worn but is still
plugged into monitor, an audible alarm will sound for 4-6
seconds, and the “OP” (operator) led will be will be blink
RED.
Normal indication.
For normal operating resistance “OPER”/”BENCH” led will
be GREEN.
High alarm.
If the operator wrist strap or worksurface mat’s resistance is
higher than maximum, the corresponding led will turn RED
and audible alarm will sound.

Calibration and Verification


The CM410 is factory calibrated and fixed. It does not re-
quire re-calibration. It is recommended to verify proper op-
eration with the CM410PV verification unit available from
Transforming Technologies.
Product Specifications
Wrist strap open circuit voltage 0.7 VDC, +0.1VDC @ < 2mA

Alarm indicators Visual, audible

Alarm set point 38 to 87pF (human body);

with1 meg ohm wrist strap resistance

Unit monitoring capabilities One person and one mat

Periodic Verification Units CM410PV: NIST Calibrated Periodic

verification tool for CM410

Dimensions/Weight 1.00” H x 2.40” W x 2.40” D

(2.54 x 6.10 x 5.84 cm) 7.80 oz


Mounting Mounting materials included

Power Supply Input: 120VAC—60hz, Output: 12VDC, 200mA

Audible Alarm 10 beeps (max); 5 seconds

Adjustment No adjustments required

Service and Warranty


Transforming Technologies, LLC provides a limited warranty for the
Model CM400, CM410 and CM420. All new products are guaranteed to be
free from defects in material and workmanship for a period of one (1) year
from the date of shipment. Liability is limited to servicing (after evaluating,
repairing or replacing) any product returned to Transforming Technologies.
The company does not warrant damage due to misuse, neglect, alteration
or accident. In no event shall Transforming Technologies be liable for collat-
eral or consequential damages. To receive service under warranty, please
contact Transforming Technologies.

3719 King Rd | Toledo, OH 43617 | P: 419-841-9552 | F: 419-841-3241 | info@transforming-technologies.com


Ohm Metrics™
Continuous Workstation Monitors - Periodic Verification Unit
Model CM410PV

VERIFICATION PROCEDURE FOR CM400, CM410, CM420:


1. Connect your Constant Monitor: CM400, CM410, CM420 to power.
2. Plug the CM410PV CPT GROUND lead (cord with Male Banana Plug on the bot-
tom of the unit) to the common ground at the workstation.
3. Connect the CM410PV BENCH GROUND lead (cord with Male Phono Plug on up-
per left of unit) to the Constant Monitor BENCH plug-in. (2)
NOTE: The CM400 does not monitor the work surface bench ground. Disre-
gard this step when testing the CM400.
4. Plug the CM410PV OPERATOR lead (cord with Male Banana Plug on the upper
right of unit) to the Constant Monitor OPERATOR input (CM410: on the body of
the monitor. CM420: To one of two Wrist Strap Remote Jack).
5. Press the green OPERATOR push & hold button on the CM410PV and the OPER-
ATOR led on the constant monitor should change from a blinking red to green.
6. Release the CM410PV’s OPERATOR push button and the OPERATOR led on
the CM410 should change to a blinking red, with momentary beeps.
7. For the CM420: Repeat steps 4 - 7 with the second OPERATOR input
8. Press the red BENCH push & hold button on the CM410PV and the BENCH led
on the CM410 should change to red, with constant beeps.
9. Release the CM410PV’s BENCH push button and the BENCH led on the CM410
should change to green, and the beeping should stop.
10. If the monitor did not pass as per the test procedure call Transforming Technolo-
gies at (419) 841-955

Please note: Allow 5-10 seconds for the constant monitor to react to the testing. The
constant monitor needs time to sense the changing resistance levels.