MCR SL Cuc 100 I

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Extract from the online

catalog
   
MCR-SL-CUC-100-I
Order No.: 2308027

http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2308027

   
Universal current transducer, for measuring AC, DC, and distorted
currents, 0 ... 100 A input current, 4 ... 20 mA output

Product notes
WEEE/RoHS-compliant since:
Commercial data 01/01/2009
GTIN (EAN) 4046356433808
sales group H537
Pack 1 pcs.
Customs tariff 90303310
Weight/Piece 0.2931 KG http://
www.download.phoenixcontact.com
Catalog page information Page 263 (NTK-2010) Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.

Technical data

Input data
Input current range 0 A ... 100 A
Overload capacity 6 x IIN
Frequency measuring range 20 Hz ... 6000 Hz
Type of connection Clamp-on cable design, 32 mm in diameter

Phoenix Contact Page 1 / 5


http://www.phoenixcontact.com.br Dec 2, 2010
MCR-SL-CUC-100-I Order No.: 2308027
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2308027

Output data
Output name Current output
Current output signal 4 mA ... 20 mA
Max. output current < 25 mA
Load/output load current output < 300 Ω

Power supply
Nominal supply voltage 24 V DC
Supply voltage range 20 V DC ... 30 V DC
Max. current consumption ((30 + IOUT) mA)
Power consumption 1.65 W

Connection data
Conductor cross section solid min. 0.25 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 2.5 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 12
Stripping length 10 mm

General data
Width 90 mm
Height 33.8 mm
Depth 85 mm
Maximum transmission error <± 1 % (of final value)
Temperature coefficient, typical 0.02 %/K (0 ... 60°C)
0.04 %/K (-40 ... 65°C)
Linearity error <± 1 % (From the range end value)
Step response (10-90%) 150 ms
Ambient temperature (operation) -40 °C ... 65 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Degree of protection IP20
Surge voltage category III
Pollution degree 2
Rated insulation voltage 300 V AC
Test voltage input/output 3.5 kV (50 Hz, 1 min.)

Phoenix Contact Page 2 / 5


http://www.phoenixcontact.com.br Dec 2, 2010
MCR-SL-CUC-100-I Order No.: 2308027
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2308027

Test voltage input/power supply 3.5 kV (50 Hz, 1 min.)


Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Color green
Housing material Frianyl B63 V0 GV30
Conformance CE-compliant
UL, USA / Canada UL applied for

Diagrams/Drawings

Application drawing
Current monitoring

Dimensioned drawing

Circuit diagram

Phoenix Contact Page 3 / 5


http://www.phoenixcontact.com.br Dec 2, 2010
MCR-SL-CUC-100-I Order No.: 2308027
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2308027

Schematic diagram

Phoenix Contact Page 4 / 5


http://www.phoenixcontact.com.br Dec 2, 2010
MCR-SL-CUC-100-I Order No.: 2308027
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2308027

Address

Phoenix Contact
Rua Gino Cesaro
BR-05038-140 Sao Paulo-SP / 169 - Água
Branca,Brazil
Phone +55/11/3871-6400
Fax +55/11/3871-6401
http://www.phoenixcontact.com.br

© 2010 Phoenix Contact


Technical modifications reserved;

Phoenix Contact Page 5 / 5


http://www.phoenixcontact.com.br Dec 2, 2010