Гидравлическая схема GMV 3010 S A5

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Гидравлическая схема GMV 3010 S

K One way valve VSH Pressure relief valve (hand pump)


ISP Inspection gauge fitting VSMA Manual lowering valve
MAN Manometer 1 Pressure relief adjustment
ML Manual lowering button Levelling speed adjustment (D-E upward, H-l
2
OLD Full load pressure limit switch (optional) downward)
Pmax Maximum pressure limit switch (optional) Deceleration adjustment (C-D upward, G-H
3
Pmin Minimum pressure limit switch (optional) downward)
PAM Hand pump (optional) 4 Up Acceleration adjustment
VB/S Pressure relief valve (differential) 5 Shut off valve for rupture valve test
VMD Down solenoid valve 6 Manometer shut-off valve
VML Levelling solenoid valve Ram pressure adjustment (for indirect acting jacks
7
VMP/S Soft-Stop solenoid valve only)
YP Pressure valve 8 Full speed adjustment
VR Check valve 9 Down speed compensation adjustment
VR1 Non return valve (inlet) 10 Pressure relief valve adjustment (hand pump)
VR2 Non return valve (outlet) s Soft-Stop adjustment (1 "1/2 and 2" only)
VRF Flow regulation valve c Hoistway proximity switch (upward)
VRFP Auxiliary flow regulation valve G Hoistway proximity switch (downward)
VRP Main non-return valve E Motor switching-off
VS Pilot valve for VB/S I VMD switching-off

VALVE BLOCK"3010/S" (Soft Stop) hydraulic circuit and working diagram