This document provides a scope of work and itemized costs for HVAC installation at a building in Ujjain, India. It includes the supply and installation of chillers, cooling towers, pumps, air handling units, ducting, grilles, diffusers and other HVAC components. The total estimated cost is over 15 lakh rupees for materials, labor, equipment rental and installation fees.
This document provides a scope of work and itemized costs for HVAC installation at a building in Ujjain, India. It includes the supply and installation of chillers, cooling towers, pumps, air handling units, ducting, grilles, diffusers and other HVAC components. The total estimated cost is over 15 lakh rupees for materials, labor, equipment rental and installation fees.
This document provides a scope of work and itemized costs for HVAC installation at a building in Ujjain, India. It includes the supply and installation of chillers, cooling towers, pumps, air handling units, ducting, grilles, diffusers and other HVAC components. The total estimated cost is over 15 lakh rupees for materials, labor, equipment rental and installation fees.
This document provides a scope of work and itemized costs for HVAC installation at a building in Ujjain, India. It includes the supply and installation of chillers, cooling towers, pumps, air handling units, ducting, grilles, diffusers and other HVAC components. The total estimated cost is over 15 lakh rupees for materials, labor, equipment rental and installation fees.
Sr.No Description of Work Unit Qty. Supply Installation Total AMT
Rate Amount Rate Amount 1 Chiller 120 TR chiller unloading charges Nos 2 7500 15000 15000 chiller shifting yard to control building Nos 2 7500 15000 15000 chiller positioning upto foundation Nos 2 17000 34000 34000 Supply of 120 TR (nominal) capacity Confrigure water cooled series. Nos 2 blue star scope 0 5"Butterfly valve for cooler & condenser Inlet & outlet Nos 8 0 750 6000 6000 6mm Vibration pad Nos 16 60 960 20 320 1280 RCC foundation for chiller Nos 2 5000 10000 5000 10000 20000 2 Condenser Water Pumps 25 mtr head Supply, Installation, Testing and Commissioning of Split Casing Chiller Water Pump (end suction type pump) set capable of delivering required flow of water against 25 mtr head, - Flow Rate - 386.1 usgpm, Pressure Drop- 11.7 ft H2O,Max Operating Nos 2 l 2000 4000 4000 Pressure- 150 psig (Water Side), Fouling Factor-0.000250 Sq ft Hr °F/Btu, Total Heat Rejection -149.6 TR Gate valve -125mm Nos 4 0 750 3000 3000 NRV valve -125 mm Nos 2 0 750 1500 1500 Y-stainer -125mm Nos 2 0 750 1500 1500 Pressuse guage -Pressure gauge of appropriate range and 150 mm. dial size Nos 4 0 50 200 200 6mm Vibration pad Nos 8 60 480 20 160 640 RCC foundation for pump Nos 2 2000 4000 1000 2000 6000 3 Chilled Water Pumps 25 mtr head Supply, Installation, Testing and Commissioning of Split Casing Chiller Water Pump (end suction type pump) set capable of delivering required flow of water against 25 mtr head, - Flow Rate Nos 2 blue star scope 2000 4000 4000 -300.0 usgpm, Pressure Drop- 9 ft H2O,Max Operating Pressure- 150 psig (Water Side), Fouling Factor-0.000100 Sq ft Hr °F/Btu Gate valve -125mm Nos 4 0 750 3000 3000 NRV valve -125 mm Nos 2 0 750 1500 1500 Y-stainer -125mm Nos 2 0 750 1500 1500 Pressuse guage -Pressure gauge of appropriate range and 150 mm. dial size Nos 4 0 50 200 200 6mm Vibration pad Nos 8 60 480 20 160 640 RCC foundation for pump Nos 2 2000 4000 1000 2000 6000 4 Cooling tower 150 TR Cooling tower 150 TR Nos 2 blue star scope 7500 15000 15000 Butter fly valves -6" Nos 4 0 750 3000 3000 Pressuse guage -Pressure gauge of appropriate range and 150 mm. dial size Nos 4 0 50 200 200 6mm Vibration pad Nos 16 60 960 20 320 1280 RCC foundation for Cooling tower Nos 2 4000 8000 2500 5000 13000 Air Handing Unit 28000 CFM Supply of double skin modular construction, Floor Mounted (FM) Air Handling Units,28000 CFM , FM, Coil-6 +2, SP- 65,Phase/HP- Nos 2 blue star scope 3 /25 Gate valves 4" Nos 8 0 750 6000 6000 Y-stainer -5" Nos 3 0 0 0 0 Pressuse guage -Pressure gauge of appropriate range and 150 mm. dial size Nos 10 0 50 500 500 6mm Vibration pad Nos 36 60 2160 20 720 2880 RCC foundation for AHU Nos 2 2500 5000 2000 4000 9000 CONDENSER and CHILLED WATER PIPING- Pipes shall be Mild 6 Steel confirming with IS 1239 and IS 3589.
150mm M 127 1200 152400 750 95250 247650
125 mm M 66 980 64680 600 39600 104280
100 MM M 16 800 12800 550 8800 21600 80 mm M 9 600 5400 500 4500 9900 50 mm M 9 400 3600 300 2700 6300 25 mm M 40 300 12000 200 8000 20000
7 CHILLED WATER PIPE INSULATION
19 mm thick nitrile pipe 125 mm dia chilled water piping SQMT 36 350 12600 150 5400 18000 Balancing Valve shall be of cast iron flanged construction with EPDM/SG iron with epoxy coated disc with built in pressure 8 drop measuring facility (pressure test cocks) to compute flow rate across the valve. The test cocks shall be long enough to protrude out of pipe insulation. 125 MM Balancing valve at the outlet of coil. Nos 0 0 0 9 Expansion tank PVC expansion tank of 1000 Ltr. Nos 1 7500 7500 1500 1500 9000 10 G. I. DUCTING & GRILLES AND DIFFUSERS Supply, fabrication, installation and testing of G. I. sheet 24 guage as per IS-655, GI sheets having minimum 120 SQMT 174.0 550 95700 200 34800 130500 g/m2 of zinc coating. 22 Gauge SQMT 224.08 650 145653.95 200 44816.6 190470.55 20 Gauge SQMT 102.24 750 76680 200 20448 97128 Canvas Connection Nos 2 2000 4000 1250 2500 6500 Supply and fixing of 25 mm thick Acoustic lining inside the ducts complete SQMT 82.00 0 150 12300 12300 Supply and fixing of 19 mm thick aluminum foil thermal insulation ducts SQMT 499 0 150 74850 74850 supply air grill with VCD SQMT 3.96 0 968 3833.28 3833.28 Return air grill with VCD SQMT 3.74 0 968 3620.32 3620.32 Supply air diffuser with VCD SQMT 5 0 0 0 SITC. volume control damper SQMT 3.99 5300 21147 968 3862.32 25009.32 Fire Dampers SQMT 2.80 0 968 2710.4 2710.4 11 MAIN AC AUXILLARY PANEL, EARTING PITS blue star scope SITC of free standing floor mounted dust and vermin proof compartmentalised cubical Electrical Main panel. SET 1 20000 20000 20000 Earthing strip of 25 X 4 mm minimum aluminum RMT 150 110 16500 35 5250 21750 12 POWER & CONTROL CABLE, BMS PLANT MANAGER ARMOURED CABLES Aluminium 3.5C X 120 sqmm RMT 64 0 95 6080 6080 ARMOURED CABLES Aluminium 3.5C X 50 sqmm RMT 77 0 75 5775 5775 ARMOURED CABLES Aluminium 4C X 25 sqmm RMT 100 0 60 6000 6000 ARMOURED CABLES Aluminium 4C X 10 sqmm RMT 100 0 50 5000 5000 PVC copper cable 2C X 1.5 sqmm RMT 100 0 20 2000 2000 13 Cable try 150X 50 mm X 1.6 mm thickness RMT 80 265 21200 125 10000 31200 300 X 150 mm X 1.6 mm tbick ness RMT 20 445 8900 125 2500 11400 14 PLC microprocess PLC Panel Set 1 blue star scope 5000 5000 5000 16 Temporery cooling proviation JOB 1 135000 135000 15000 15000 150000
1 Three way valve Nos 2 2000 4000 4000
4 Diffrance amount of Flanges change Lot 1 21600 6 fire panel Nos 1 14000 8 Gate Valve 3" Nos 1 4750 4750 9 Flanges for 3" Gate Valve Nos 2 1200 10 Flanges for 3 way Valve Nos 6 3600
SUB TOTAL 831800.95 527875.92 1472826.87
GST @ 18% 265109 GRAND TOTAL 1737936 GRAND TOTAL(in words) Condenser pump - Qty - 2 No.s Evaporator Pump - Qty - 2 no.s Leaving Temperature 94.30 °F Leaving Temperature Entering Temperature 85.00 °F Entering Temperature Delta T 9.30 °F Delta T Flow Rate 386.1 usgpm Flow Rate Pressure Drop 11.7 ft H2O Pressure Drop Max Operating Pressure 150 psig (Water Side) Max Operating Pressure Fouling Factor 0.000250 Sq ft Hr °F/Btu Fouling Factor Total Heat Rejection 149.6 TR Head Head 25 Mtr. porator Pump - Qty - 2 no.s 44.00 °F 54.00 °F 10.00 °F 300.0 usgpm 9.00 ft H2O 150 psig (Water Side) 0.000100 Sq ft Hr °F/Btu 25 Mtr. Valves: 8.5.1. The gates valves shall be cast iron body confirming with IS standards. 8.5.2. Balancing valve shall be of cast iron flanged construction with EPDM/SG iron with epoxy coated disc with built in pressure drop measuring facility (pressure test cocks) to compute flow rate across the valve. The test cocks shall be long enough to protrude out of pipe insulation. 8.5.3. Non return valves shall be of gun metal construction upto 65 mm, the metal conforming to class 2 of IS: 778. For 75 mm and above, the valve shall be of bronze or gun metal, body being of cast iron. While screwed or flanged ends may be provided upto 65 mm, flanged ends shall be provided for larger sizes. 8.6. Strainers 8.6.1. 'Y' strainers shall be provided on the inlet side of each air-handling unit and pump in chilled water and condenser water circuit. 8.6.2. Strainers shall be provided with equal size isolating gate valves on either side so that the strainers may be cleaned without draining the system. Capacity 28000CFM, Static Pressure 65 mm Wg. The air handling unit shall be of double skin construction, draw through type in sectionalized construction consisting of blower section, coil section, filter section and insulated drain pan. The unit may be vertical or horizontal type. The coil shall be designed for a face velocity of air not exceeding 155m/min. The air outlet velocity from the blower fan shall not exceed 610 m/min. Noise level at a distance of 2M from AHU shall not exceed 75 dBA. Double skin panels shall be 25mm+1 thick, made of 0.6mm (minimum) preplasticized and pre-painted with PVC guard, galvanized steel sheet on outside and 0.8mm galvanized sheet inside with Polyurethane foam insulation of density not less than 38 kg/cu. m injected in between by injection molding machine. The entire housing shall be mounted on galvanized steel channel frame work made out of G.I. sheet of thickness not less than 2mm. For higher capacity AHUs hot dip galvanized steel channel framework made of minimum 3 mm thick G.S. sheet shall be used. The coil shall be made from seamless solid drawn copper tubes. The minimum thickness of tube shall be 0.5 mm for the cooling coils. The depth of the coil shall be such as to suit the requirements as per the application. The coil shall be minimum 4 rows deep. In case of 8 rows deep coils, it shall be made of 2x4 rows deep coils with a spacing of 200mm between the two coils, access door and independent drain pan. The headers shall be of copper and shall be complete with water in/out connections, vent plug on top and drain at the bottom. The coil shall be designed to provide water velocity between 0.6 to 1.8 m/s in the tubes. The fins shall be of aluminum. The minimum thickness of the fins shall be 0.15 mm nominal. The no. of fins shall not be less than 4.7 per cm length (12-13 per inch) of coil. Fins may be of either spiral or plate type. Water coils shall be designed for a minimum working pressure of 10 kg./sq.cm. The supply air fan shall be AMCA certified centrifugal type with forward/backward curved blades double inlet double width type. Fan outlet velocity shall be restricted within 9.2 m/s. The fan motor shall be totally enclosed fan cooled squirrel cage induction motor with IP-54 protection & selected running. The motor shall be suitable for operation on 415 + 10%V, 3 phase, 50 Hz, A.C. supply. The fan motor s premium efficiency IE3 class, as per IS 12615. The motor rating (exclusive of service factor) shall be minimum 1 limit load power required (including the transmission losses) at operating condition. The motor shall be suitably d for use with variable frequency drive. Pre filter section with MERV-7 filters