2/10/2014 Document 1549175.

EM 12c: Blackout Failed to Stop with Error "Partial Blackout - Stop Failed" (Doc ID
1549175.1)
Modified: 19-Jun-2013 Type: PROBLEM

In this Document

Symptoms
Cause
Solution
References

APPLIES TO:

Enterprise Manager Base Platform - Version 12.1.0.2.0 to 12.1.0.2.0 [Release 12.1]


Information in this document applies to any platform.

SYMPTOMS

A Blackout job can not be stopped from 12c OEM Console.


When trying to end blackout, it returns status of "Partial Blackout - Stop Failed".

CAUSE

As per the log emoms_pbs.trc file from ../gc_inst/em/EMGC_OMS1/sysman/log/,

following are the error messages at the time of Stop Blackout:

JobWorker
1082638:JobThreadPool:Long-System:Thread-1306992] INFO commands.StopBlackout
executeCommand.301 - stopBlackout:
java.lang.NullPointerException
at java.text.SimpleDateFormat.parse(SimpleDateFormat.java:1235)
at java.text.DateFormat.parse(DateFormat.java:335)
at
oracle.sysman.emdrep.jobs.commands.StopBlackout.stopBlackout(StopBlackout.java:138)
at
oracle.sysman.emdrep.jobs.commands.StopBlackout.executeCommand(StopBlackout.java:268)
at
oracle.sysman.emdrep.jobs.CommandStepExecutor.execute(CommandStepExecutor.java :154)

This is due to an incorrect version of the Patch 16048324 applied to the OMS. This incorrect patch was initially released
in the month of February.

SOLUTION

To fix the issue:

1. Rollback the Patch 16048324 if you have on OMS_HOME.


2. Please download the Patch 16805137 and apply it to OMS_HOME as per the instructions.

https://support.oracle.com/epmos/faces/DocumentDisplay?_adf.ctrl-state=1amskqto0w_145&id=1549175.1 1/2
2/10/2014 Document 1549175.1

REFERENCES

BUG:16634271 - BLACKOUT JOB HAS STATUS OF PARTIAL BLACKOUT - STOP FAILED

https://support.oracle.com/epmos/faces/DocumentDisplay?_adf.ctrl-state=1amskqto0w_145&id=1549175.1 2/2