P12-217 RAP: Initial Actions

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

A B

P12-217 RAP • Safety Door Slide for binding ( PL 8-F4)


• Safety Door Guide for damage ( PL 8-F4)
Fault Code, P12-217, indicates that the Stacker Safety Door failed to actuate the Stacker Door
• Stacker Drawer Safety Switch bracket is bent
Down Sensor, Q1239, or the Stacker Door Up Sensor, Q1238, within 3.5 seconds after the
If the problem persists, replace the Stacker Safety Door Motor, MOT1215 ( PL 8-F4)
Stacker Motor, MOT1215, was energized.

The Stacker Door Down Sensor display is L.


Initial Actions Y N
Go to Table 23 in Subsystem Maintenance in Section 1. Go to Flag 3. Check the Stacker Door Down Sensor circuit (Go to GR 2 Generic
Sensor RAP, Generic Sensor RAP, General Procedures).
Ensure that the Stacker Door Up and Stacker Door Down Sensors are not obstructed.
Actuate the Stacker Door Up Sensor. (With Finisher TAG F-55 or TAG F-251, open the
Ensure that the Stacker Drawer is in the Home Position. Finisher Top Cover and Block the Stacker Door Up Sensor.) The display changes from
H to L.
NOTE: The 115 VAC for the Stacker Door Motor, MOT1215, is controlled by the Finisher Inter- Y N
lock Relay, K1206 (K7), and the Stacker Door Safety Switch, S1234. Go to Flag 2c (W/ TAG F-55), Flag 2a (W/O TAG F-55 or F-251), or Flag 2b (W/ TAG
F-251) Check the Stacker Door Up Sensor circuit (Go to GR 2 Generic Sensor RAP,
NOTE: The path to the diagnostic routines that are written in this manual are only for the
DT135. For the diagnostic paths for the 6100/6135, go to Table 1, Diagnostic Path Generic Sensor RAP, General Procedures).
Workarounds in the Introduction.
Adjust the Stacker Door Down Sensor, ADJ 12.145.
Procedure
Bypass the Finisher Bypass Interlock. Enter dC330 [12E]. Actuate the Stacker Door Safety Actuate the Stacker Door Up Sensor (with Finisher TAG F-55 or TAG F-251, open the Finisher
Top Cover and block the Stacker Door Up Sensor). The display changes from H to L.
Switch. The display changes from H to L.
Y N Y N
Go to P12-754 RAP Go to Flag 2. Check the Stacker Drawer Up Sensor circuit (Go to GR 2 Generic Sensor
RAP, Generic Sensor RAP, General Procedures).
The Stacker Safety Door is closed.
Y N Remove the cheater and close the doors and top cover. Select [Stacker Door Up] motor.
Press the Start button. The Stacker Safety Door moves up.
Enter dC330 [12E]. The Stacker Drawer In Sensor display is L.
Y N Y N
Go to Flag 4. Check the Stacker Drawer In Sensor circuit (Go to GR 2 Generic Sen- The Stacker Safety Door Motor, MOT1215 attempts to move.
Y N
sor RAP, Generic Sensor RAP, General Procedures).
115 VAC is measured between 4TB3-5 and 4TB2-5.
Select [Stacker Door Down] motor. Press the Start button. The Stacker Safety Door Y N
The Printer is configured for 60 Hz power.
moves down.
Y N Y N
The Stacker Safety Door Motor, MOT1215 attempts to move. Go to P01-712 RAP
Y N
115 VAC is measured between 4TB3-5 and 4TB2-5. Go to P01-705 RAP
Y N
Go to Flag 1. Check the Stacker Door Motor circuit.
The Printer is configured for 60 Hz power.
Y N
Go to P01-712 RAP Check the following:
• One-Way Clutch on the Stacker Safety Door Motor for slipping ( PL 8-F4)
Go to P01-705 RAP • Safety Door Rack and Pinion interface for wear ( PL 8-F4)
• Safety Door Slide for binding ( PL 8-F4)
Go to Flag 1. Check the Stacker Door Motor circuit. • Safety Door Guide for damage ( PL 8-F4)
If the problem persists, replace the Stacker Safety Door Motor ( PL 8-F4)
Check the following:
• One-Way Clutch on the Stacker Safety Door Motor is slipping ( PL 8-F4)
The Stacker Door Up Sensor display is L.
• Safety Door Rack and Pinion interface for wear ( PL 8-F4)

A B
Status Indicator RAPs 11 / 2006 Reissue
P12-217 RAP 2-1010 DocuTech135/6135/6115/6100
Y N
Adjust the Stacker Door Up Sensor W/O TAG F-55 or TAG F-251, ADJ 12.147.

Actuate the Stacker Door Down Sensor. The display changes from H to L.
Y N
Go to Flag 3. Check the Stacker Door Down Sensor circuit.

Adjust the Stacker Door Down Sensor, ADJ 12.145.

Reissue 11 / 2006 Status Indicator RAPs


DocuTech135/6135/6115/6100 2-1011 P12-217 RAP
PL 5-
D4

PL 8-
G2

PL 8-
F4

PL 8-
F8

Figure 1 P12-217 Circuit Diagram

Status Indicator RAPs 11 / 2006 Reissue


P12-217 RAP 2-1012 DocuTech135/6135/6115/6100
PL 5-
PL 5-
D4
D2

PL 8-
PL 8- G2
G2

Figure 2 P12-217 Circuit Diagram

Reissue 11 / 2006 Status Indicator RAPs


DocuTech135/6135/6115/6100 2-1013 P12-217 RAP
PL 5-
D4

PL 8-
G2

Figure 3 P12-217 Circuit Diagram

Status Indicator RAPs 11 / 2006 Reissue


P12-217 RAP 2-1014 DocuTech135/6135/6115/6100
PL 5-
D4
PL 8-
G2

PL 5-
D4
PL 8-
G2

Figure 4 P12-217 Circuit Diagram

Reissue 11 / 2006 Status Indicator RAPs


DocuTech135/6135/6115/6100 2-1015 P12-217 RAP