Summary and Conclusion
Newmark Engineering, P.C. Job BBG-Bio-Vault SOE
8 Hillside Ave SHEET SC-01 OF SC-01
Montclair, NJ. 07042 BY GSN DATE 3-26-18
646-529-2577 CHECKED DATE
2. Analysis and Conclusion: STAAD Analaysis has been performed for Soldier Piles for each
stage of construction (Stage 1, Initial 7’ Excavation/Placement of Temp Strut, Stage 2
Excavation and installation of 6” base slab, Stage 3 Removal of Temp Strut and Installation
of CIP Concrete Bio-Vault). STAAD analysis has also been performed for upper steel
strut/waler frame using maximum staged forces imposed by soldier piles. Stresses in all
SOE elements remain safely below allowable values at all times during construction. Based
on the foregoing analysis, the SOE and sequence of construction for Bio-Vault is safe,
conformant with OSHA and contract document requirements and recommended herewith.
Shop Drawings
Soldier Pile and Lagging SOE
Dual Bio-Filter Vault
SOE-01 to SOE-05
WA
SHI
SEE SHT SOE-02 NGTO
NA
VEN
UE
JAPANESE POND
0 30 60
SCALE IN FEET
2'-6"
(TYP.)
3'-0"
46'-8"
2 SP @ 8'-9"± = 17'-6"
2 SP @ 8'-9"± = 17'-6"
W8x58 WALE TYP
13'-4"
18'-4"
3" (ACTUAL) TIMBER
2'-6"
LAGGING T&G
W8x58 WALE TYP W8x58 WALE TYP
51'-8"
PLAN - SOE A
BIO-VAULT
5
8"x8" BRG W8X58
1
5
8" x8" BRG STIFFENER
7" x4x34
STIFFENER ⅊
1
4 W8x58 STIFFENER (EACH SIDE)
(BOTH SIDES) 4
1
W8x58
4
1
4
SCALE IN FEET
1'-6"
(TYP.) W=1.15 K/LF
3 W8x58 STRUT/WALER
H=7.00'
4 3" (ACTUAL)
7'-0"
TIMBER
4 4 LAGGING T&G
(STAGE 1 (STAGE 1
EXCAV.) EXCAV.) P'=80PSF
LIMIT OF
P2=360PSF
12'-6"
STAGE 1
10'-6"
EXCAVATION P1=280PSF
5 TEMP 10x10 TIMBER STRUT
D1=2.71'
R3=1.00 K/LF
D2=2.35'
8'-0"
LOADING DIAGRAM
SECTION A-A N.T.S.
6"
1'-6"
(TYP.) W=0.69 K/LF
W8x58 STRUT/WALER
P2=405PSF
P1=325PSF
5'-6"
P'=80PSF
H1=12.50'
12'-6"
1 1
5'-0"
(STAGE 2 (STAGE 2
EXCAV.) EXCAV.)
LIMIT OF
EQ
STAGE 2
6"
EXCAVATION
EQ
1'-6"
(TYP.) W=2.88 K/LF
W8x58 STRUT/WALER
P2=405PSF
5 P1=325PSF
3" (ACTUAL)
6 6
(BACK (BACK
TIMBER P'=80PSF
LAGGING T&G
H1=12.50'
FILL FILL
12'-6"
& &
REMOVAL) REMOVAL)
10'-6"
2 REMOVE TEMP
STRUT
4
3
6"
1
TOE
SECTION A-A
2'-6"
LOADING DIAGRAM
STAGE 3 - CONSTRUCT FILTER VAULT N.T.S.
DESIGN CRITERIA:
SUGGESTED SEQUENCE OF CONSTRUCTION:
= UNIT WEIGHT OF SOIL = 120 PCF
1. CURE TO ALLOW BOTTOM SLAB TO ATTAIN 7-DAY INITIAL STRENGTH , UNLESS HIGH-EARLY w = UNIT WEIGHT OF WATER = 62.4 PCF
STRENGTH (RAPID CURING) CONCRETE IS USED FOR BASE SLAB. s = SUBMERGED UNIT WEIGHT OF SOIL = 57.6 PCF
2. AFTER ATTAINMENT OF 7-DAY (1500PSI) STRENGTH HAS BEEN ATTAINED, REMOVE = INTERNAL FRICTION ANGLE OF SOIL = 30°
TEMPORARY 10X10 STRUTS.LAYOUT AND DRIVE 15’ LONG HP 10X42 SOLDIER PILES. AFTER (1-SIN
Kra = = 0.333 FOR ACTIVE EARTH PRESSURE
SOLDIER PILES HAVE BEEN DRIVEN TO 15’ DEPTH, TACK FILLET WELD W8X58 WALER TO SOLDIER (1+SIN
PILES. (1+SIN
Krp = = 3.000 FOR PASSIVE EARTH PRESSURE
3. FORM, REINFORCE AND PLACE FILTER VAULT BOTTOM SLAB CONCRETE. (1-SIN
4. FORM, REINFORCE AND PLACE FILTER FAULT WALL CONCRETE. Ps = x H' = 240 PSF
P' = Kra x Ps = 80 PSF
5. FORM, REINFORCE AND PLACE FILTER VAULT ROOF SLAB CONCRETE. P1 = (0.8 Kra) x x H= 325 PSF
6. REMOVE SOLDIER PILES, LAGGING AND TOP STRUT/WALER FRAMES WHILE SIMULTANEOUSLY P2 = P'+ P1= 405 PSF
BACKFILLING VAULT. CONTRACTOR MAY, AT HIS OPTION, CUT SOLDIER PILES 4’ BGS AND LEAVE IN
0 1 2 3 PLACE. GR50 STEEL STRUT/WALER FRAME AND SOLDIER PILES
SCALE IN FEET
LAGGING Fb = 1,300 psi TIMBER (SOUTHERN PINE #1 OR BETTER)
7. COMPLETE VAULT CONSTRUCTION BY FORMING AND PLACING PERSONNEL HATCH AND RISER. GR36 STEEL 1" ⅊
BROOKLYN BOTANIC GARDEN
NEWMARK ENGINEERING, P.C. BIO-FILTER VAULT SOUTH GARDEN PROJECTS
PHASE 3
Civil-Structural- Survey&Mapping - Monitoring&Instrumentation STAGE 3 - CONSTRUCT FILTER VAULT BOROUGH OF BROOKLYN
8 HILLSIDE AVE, SUITE 205, MONTCLAIR, NJ 07042
SECTION A-A DRAWING:
SOE-05
DATE: MARCH 2018 SHEET
5 OF 5
Calculations
Soldier Pile and Lagging SOE Bio-Vault
C1-01 to C1-10
Newmark Engineering, P.C. JOB BC?~ Bi.io-'lf!m!c:r- ~
8 H ILLSIDE AVE SHEnCJ-/ OF _ __
MONTCLAIR , NJ _' 07042 BY . G:-~ DATE _3-2f-te>
646-529-2577 CHECKED DATE
cpz31::>
~~
\a1~~?{'1?1()
~f ~f,/le'. : a~~,'5'-~i?-'rl~.rl.
,z
-- -
f ; 3-·C)_
~ ~ -
Newmark Engineedng, P .C. JOB B~- &o'JA:.:tC ~
8 HILLSIDE AVE SHEEiC 1-2,...
OF - - - -
MONTCLAIR, NJ. 07042 BY a_~ DATE
646-529-2577 I CHECKED _ _ _ DATE
Il
"-
' -
- T
i
~ M: tai.3~4_:--_
M; _:o,'1.6 pr-.1., ~·
-- ~
' ~, ·-- -
- + - L •
Newmark Engineering, P .C. JOB B~ ~wa- scse
8 HILLSIDE AVE SHEETO I ? OF - - - , , , . - - -
MONTCLAIR , NJ .' 07042 BY . ~9N DATE 3---2J..f6
646-529-2577 CHECKED DATE
- // J( ·_
- ---.
'
---- - - ---
/
- - - --
- -- -- -
'
Newmark Engineering, P.C. JOB . BB<; . BltS>-YA<IL-'"1. ~
8 HILL SIDE AVE SHEET C J 4 OF
MONTC LAIR, NJ. 07042 BY DATE 3-£2.d6
646-529-2577 CHECKED DATE
- - - --- ---
t -
+
Newmark Engineering; P .C. JOB ~- ~ ~
8 HILLSIDE AVE SHEET <:;,J:5 OF _ _ __
MONTCLAIR, NJ: 07042 BY ~ DATE ' 2-2..fd!
646-529-2577 CHECKED DATE
-
\ I
I
I
-~1
I
-!
i- t ~ _J - ·~
+-----i----- - -
~ 1
I I
--- - ..---
L
!
- ~L
'
- I
t
-+
--~--~-- ---- -
~ -- - -~
' -- ~ - +
- -- -. - -
'
N ewmark Engi!Iiteeri.ng, P.C. JOB TtG: \Lt\cX\ ~
8 HILLSIDE AVE SHEE~=-
Q\~
-'--- OF --:----....,....,--
M O NTC LAIR, NJ. 0 7 042 BY ~ DATE 3-'2:2=t9
646-529-2577 CHECKED DATE
=:+~~ ~ ~
-__~ ~ --
- -r ~;_ b"~b~"- ~ {J)Llij_~),_: -(8,0~- - - . ~ - ~ ~ +
--- -- +-
..._ - - ~ ·• - r - ,
~ @ {QflO ~ _~ . _ _ _ _ + ~ _ _ __
-
_?ao'-/l~ . Hi~~ . N<R.!!2l:ffe> ,
' ·. ~
· fw-_<100 ~(tu@:- o,cij -:i,•/K _ ·.
~ ~bo6 f??JOO {r,r5o.u2 fPr_ ~-~)_
T i-- -.--- -
I
+ - r -
r ~ - - +
+ 1- T" - - -
Newmark Engineering, P .C. JOB ~ &oJJ A:at' Sif£
8 HILLSIDE AVE SHEET Cl-"'"""-J
i.------'q'----- OF
MONTCLAIR, NJ. 07042 BY ~ DATE
646-529-2577 CHEC K ED ----DATE
I
~P. ~ J. ,,hf91
~ - 7t<iJQl1t~~
'E~
I ~~~
~
,- ~~~~~~~
~- 1
~~:t:;,Z_~'f 5 (B.5
-~2. PA!! '1tr
I
I~
~I
Newmarlk Engineering, P .C.
8 HILLSIDE AVE SHEET Cf:1D OF _ __
- ~ - - ._._
+- t. • '··- - ~
- ~>z;s;'(lf ~~
~ ; 1\'fJf>
. I
-- --.-----____.___ - _._ I - -
-© 25ftf - 1o:Jo - - t {).0£3 n~:tb ·1'6Ub rc:io 2-'Vt.15 - ()ji32- o~g1 , o.~5
****************************************************
* *
* STAAD.Pro *
* Version 2005 Bld 1002.US *
* Proprietary Program of *
* Research Engineers, Intl. *
* Date= MAR 22, 2018 *
* Time= 11:16:27 *
* *
* USER ID: Newmark Engineering, P.C. *
****************************************************
1. STAAD PLANE
INPUT FILE: STAGE 1.STD
2. START JOB INFORMATION
3. JOB NAME BBG PHASE 3A BIO FILTER SOE
4. JOB CLIENT KELCO CONSTRUCTION
5. JOB NO BIO FILTER VAULT SOE
6. JOB REV HP10X42 SOLDIER PILE
7. JOB PART STAGE 1 - INITIAL 7' EXCAVATION
8. ENGINEER NAME GSN
9. ENGINEER DATE 3/21/18
10. END JOB INFORMATION
11. INPUT WIDTH 79
12. UNIT FEET POUND
13. JOINT COORDINATES
14. 1 0 0 0; 2 1.5 0 0; 3 9.71 0 0
15. MEMBER INCIDENCES
16. 1 1 2; 2 2 3
17. DEFINE MATERIAL START
18. ISOTROPIC TIMBER
19. E 2.448E+008
20. POISSON 0.4
21. DENSITY 50
22. ISOTROPIC CONCRETE
23. E 4.536E+008
24. POISSON 0.17
25. DENSITY 149.99
26. ALPHA 5.5E-006
27. DAMP 0.05
28. ISOTROPIC STEEL
29. E 4.176E+009
30. POISSON 0.3
31. DENSITY 489.024
32. ALPHA 6.5E-006
33. DAMP 0.03
34. ISOTROPIC SOPN_DSS_3X12
35. E 2.736E+008
36. POISSON 0.15
37. DENSITY 25
38. ALPHA 5.5E-006
39. END DEFINE MATERIAL
40. MEMBER PROPERTY AMERICAN
P R O B L E M S T A T I S T I C S
-----------------------------------
NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 3/ 2/ 2
ORIGINAL/FINAL BAND-WIDTH= 1/ 1/ 4 DOF
TOTAL PRIMARY LOAD CASES = 1, TOTAL DEGREES OF FREEDOM = 5
SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 12.0/ 620453.1 MB
2 195.958 GY 7.48
2 207.155 GY 7.59
2 218.353 GY 7.70
2 229.550 GY 7.82
2 240.748 GY 7.93
2 251.945 GY 8.04
2 263.143 GY 8.15
FOR LOADING - 1
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 0.00000E+00-6.24750E+02 0.00000E+00 0.00000E+00 0.00000E+00-1.65750E+02
2 0.00000E+00-8.88868E+03 0.00000E+00 0.00000E+00 0.00000E+00-1.22356E+04
3 0.00000E+00-8.64427E+03 0.00000E+00 0.00000E+00 0.00000E+00 1.32529E+04
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
2 0.00 -8888.68 0.00 0.00 0.00 -12235.61
0.00 -842.61 0.00 0.00 0.00 12235.61 111110
MEMB DISTANCE FY LD MZ LD FZ LD MY LD
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 1, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 0.00 0.00 1 956.25 1.50 1
| 0.00 0.00 1 0.00 0.00 1 0.00 0.00 1
| MIN. -1402.50 1.50 1 0.00 0.00 1
| 0.00 1.50 1 0.00 1.50 1 0.00 1.50 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 2, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 8328.79 0.00 1 956.25 0.00 1
| 0.00 0.00 1 0.00 0.00 1 0.00 0.00 1
| MIN. -8426.41 8.21 1 -19287.34 4.11 1
| 0.00 8.21 1 0.00 8.21 1 0.00 8.21 1
|---------------------------------------------------------------------------
59. FINISH
************************************************************
* For questions on STAAD.Pro, please contact *
* Research Engineers Offices at the following locations *
* *
* Telephone Email *
* USA: +1 (714)974-2500 support@reiusa.com *
* CANADA +1 (905)632-4771 detech@odandetech.com *
* CANADA +1 (604)629 6087 staad@dowco.com *
* UK +44(1454)207-000 support@reel.co.uk *
* FRANCE +33(0)1 64551084 support@reel.co.uk *
* GERMANY +49/931/40468-71 info@reig.de *
* NORWAY +47 67 57 21 30 staad@edr.no *
* SINGAPORE +65 6225-6015/16 support@reiasia.net *
* INDIA +91(033)2357-3575 support@calcutta.reiusa.com *
* JAPAN +81(03)5952-6500 eng-eye@crc.co.jp *
* CHINA +86(411)363-1983 support@reiasia.net *
* *
* North America support@reiusa.com *
* Europe support@reel.co.uk *
* Asia support@reiasia.net *
************************************************************
****************************************************
* *
* STAAD.Pro *
* Version 2005 Bld 1002.US *
* Proprietary Program of *
* Research Engineers, Intl. *
* Date= MAR 22, 2018 *
* Time= 11:23:17 *
* *
* USER ID: Newmark Engineering, P.C. *
****************************************************
1. STAAD PLANE
INPUT FILE: STAGE 2.STD
2. START JOB INFORMATION
3. JOB NAME BBG PHASE 3A BIO FILTER SOE
4. JOB CLIENT KELCO CONSTRUCTION
5. JOB NO BIO FILTER VAULT SOE
6. JOB REV HP10X42 SOLDIER PILE
7. JOB PART STAGE 2 - TEMP TIMBER STRUT
8. ENGINEER NAME GSN
9. ENGINEER DATE 3/21/18
10. END JOB INFORMATION
11. INPUT WIDTH 79
12. UNIT FEET POUND
13. JOINT COORDINATES
14. 1 0 0 0; 2 1.5 0 0; 3 12.5 0 0; 4 7 0 0
15. MEMBER INCIDENCES
16. 1 1 2; 2 2 4; 3 4 3
17. DEFINE MATERIAL START
18. ISOTROPIC TIMBER
19. E 2.448E+008
20. POISSON 0.4
21. DENSITY 50
22. ISOTROPIC CONCRETE
23. E 4.536E+008
24. POISSON 0.17
25. DENSITY 149.99
26. ALPHA 5.5E-006
27. DAMP 0.05
28. ISOTROPIC STEEL
29. E 4.176E+009
30. POISSON 0.3
31. DENSITY 489.024
32. ALPHA 6.5E-006
33. DAMP 0.03
34. ISOTROPIC SOPN_DSS_3X12
35. E 2.736E+008
36. POISSON 0.15
37. DENSITY 25
38. ALPHA 5.5E-006
39. END DEFINE MATERIAL
40. MEMBER PROPERTY AMERICAN
P R O B L E M S T A T I S T I C S
-----------------------------------
NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 4/ 3/ 2
ORIGINAL/FINAL BAND-WIDTH= 2/ 2/ 5 DOF
TOTAL PRIMARY LOAD CASES = 1, TOTAL DEGREES OF FREEDOM = 8
SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 12.0/ 620456.2 MB
FOR LOADING - 1
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 0.00000E+00-2.58150E+03 0.00000E+00 0.00000E+00 0.00000E+00-6.45375E+02
2 0.00000E+00-1.20470E+04 0.00000E+00 0.00000E+00 0.00000E+00-8.03133E+03
3 0.00000E+00-9.46550E+03 0.00000E+00 0.00000E+00 0.00000E+00 8.67671E+03
4 0.00000E+00-1.89310E+04 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
2 0.00 -12047.00 0.00 0.00 0.00 -8031.33
0.00 6179.95 0.00 0.00 0.00 8031.33 111110
MEMB DISTANCE FY LD MZ LD FZ LD MY LD
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 1, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 0.00 0.00 1 3872.25 1.50 1
| 0.00 0.00 1 0.00 0.00 1 0.00 0.00 1
| MIN. -5163.00 1.50 1 0.00 0.00 1
| 0.00 1.50 1 0.00 1.50 1 0.00 1.50 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 2, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 704.05 0.00 1 52060.25 5.50 1
| 0.00 0.00 1 0.00 0.00 1 0.00 0.00 1
| MIN. -18226.95 5.50 1 3872.25 0.00 1
| 0.00 5.50 1 0.00 5.50 1 0.00 5.50 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 3, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 18931.00 0.00 1 52060.24 0.00 1
| 0.00 0.00 1 0.00 0.00 1 0.00 0.00 1
| MIN. 0.00 5.50 1 0.00 5.50 1
| 0.00 5.50 1 0.00 5.50 1 0.00 5.50 1
|---------------------------------------------------------------------------
57. FINISH
************************************************************
* For questions on STAAD.Pro, please contact *
* Research Engineers Offices at the following locations *
* *
* Telephone Email *
* USA: +1 (714)974-2500 support@reiusa.com *
* CANADA +1 (905)632-4771 detech@odandetech.com *
* CANADA +1 (604)629 6087 staad@dowco.com *
* UK +44(1454)207-000 support@reel.co.uk *
* FRANCE +33(0)1 64551084 support@reel.co.uk *
* GERMANY +49/931/40468-71 info@reig.de *
* NORWAY +47 67 57 21 30 staad@edr.no *
* SINGAPORE +65 6225-6015/16 support@reiasia.net *
* INDIA +91(033)2357-3575 support@calcutta.reiusa.com *
* JAPAN +81(03)5952-6500 eng-eye@crc.co.jp *
* CHINA +86(411)363-1983 support@reiasia.net *
* *
* North America support@reiusa.com *
* Europe support@reel.co.uk *
* Asia support@reiasia.net *
************************************************************
****************************************************
* *
* STAAD.Pro *
* Version 2005 Bld 1002.US *
* Proprietary Program of *
* Research Engineers, Intl. *
* Date= MAR 22, 2018 *
* Time= 15:52:55 *
* *
* USER ID: Newmark Engineering, P.C. *
****************************************************
1. STAAD SPACE
INPUT FILE: STRUT WALER FRAME.STD
2. START JOB INFORMATION
3. JOB NAME BROOKLYN BOTANICAL GARDENS
4. JOB CLIENT KELCO CONSTRUCTINO
5. JOB NO FILTER VAULT SOE
6. JOB PART STRUT/WALER FRAME CHAMBER 2
7. ENGINEER NAME GSN
8. ENGINEER DATE 3/22/18
9. END JOB INFORMATION
10. INPUT WIDTH 79
11. UNIT FEET KIP
12. JOINT COORDINATES
13. 1 0 0 0; 2 25.167 0 0; 4 25.833 0 0; 5 51 0 0; 6 51 0 17.666
14. 8 25.8333 0 17.6666; 9 25.167 0 17.667; 10 0 0 17.666; 11 0 0 14.667; 12 0 0 3
15. 13 3 0 0; 14 3 0 17.667; 15 48 0 0; 16 48 0 17.667; 17 51 0 3; 18 51 0 14.6666
16. MEMBER INCIDENCES
17. 1 1 13; 4 4 15; 5 5 17; 6 6 16; 9 9 14; 10 10 11; 11 2 9; 12 4 8; 13 11 12
18. 14 12 1; 15 13 2; 16 14 10; 17 12 13; 18 11 14; 19 15 5; 21 17 18; 22 18 6
19. 23 15 17; 24 18 16; 25 16 8
20. MEMBER PROPERTY AMERICAN
21. 1 4 TO 6 9 TO 19 21 TO 25 TABLE ST W8X58
22. DEFINE MATERIAL START
23. ISOTROPIC MATERIAL1
24. POISSON 0.45
25. ISOTROPIC STEEL
26. E 4.176E+006
27. POISSON 0.3
28. DENSITY 0.489024
29. ALPHA 6.5E-006
30. DAMP 0.03
31. END DEFINE MATERIAL
32. CONSTANTS
33. BETA 90 ALL
34. MATERIAL STEEL MEMB 1 4 TO 6 9 TO 19 21 TO 25
35. SUPPORTS
36. 1 5 6 10 PINNED
37. MEMBER RELEASE
38. 17 END MY MZ
39. 17 START MY MZ
40. 18 START MY MZ
41. 18 END MY MZ
42. 23 START MY MZ
43. 23 END MY MZ
44. 24 START MY MZ
45. 24 END MY MZ
46. LOAD 1 LOADTYPE NONE TITLE LOAD CASE 1 - EARTH PRESSURE
**WARNING- THIS STRUCTURE IS DISJOINTED. IGNORE IF
MASTER/SLAVE OR IF UNCONNECTED JOINTS.
47. MEMBER LOAD
48. 1 4 TO 6 9 10 13 TO 16 19 21 22 25 UNI Y 2.88
49. PERFORM ANALYSIS PRINT ALL
P R O B L E M S T A T I S T I C S
-----------------------------------
THE ABOVE CONDITIONS COULD ALSO BE CAUSED BY VERY STIFF OR VERY WEAK
ELEMENTS AS WELL AS TRUE SINGULARITIES.
FOR LOADING - 1
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 4.32000E+00 0.00000E+00 4.32000E+00 0.00000E+00 0.00000E+00 0.00000E+00
2 0.00000E+00 0.00000E+00 3.19205E+01 0.00000E+00 1.17930E+02 0.00000E+00
4 0.00000E+00 0.00000E+00 3.19205E+01 0.00000E+00-1.17930E+02 0.00000E+00
5-4.32000E+00 0.00000E+00 4.32000E+00 0.00000E+00 0.00000E+00 0.00000E+00
6-4.32058E+00 0.00000E+00-4.32000E+00 0.00000E+00-8.64556E-04 0.00000E+00
8 5.76782E-04 0.00000E+00-3.19200E+01 0.00000E+00 1.17927E+02 0.00000E+00
9 0.00000E+00 0.00000E+00-3.19205E+01 0.00000E+00-1.17930E+02 0.00000E+00
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
1 4.32 0.00 4.32 0.00 0.00 0.00
21.12 0.00 17.33 0.00 0.00 0.00 111000
MEMB DISTANCE FY LD MZ LD FZ LD MY LD
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 1, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 22.04 3.00 1 0.05 0.00 1
| 0.00 0.00 1 0.00 0.00 1 53.08 T 0.00 1
| MIN. 13.40 0.00 1 -53.12 3.00 1
| 0.00 3.00 1 0.00 3.00 1 53.08 T 3.00 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 4, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 31.04 22.17 1 114.02 11.08 1
| 0.00 0.00 1 0.00 0.00 1 0.00 T 0.00 1
| MIN. -32.80 0.00 1 -72.63 0.00 1
| 0.00 22.17 1 0.00 22.17 1 0.00 T 22.17 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 5, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 36.29 3.00 1 0.05 0.00 1
| 0.00 0.00 1 0.00 0.00 1 35.06 T 0.00 1
| MIN. 27.65 0.00 1 -95.84 3.00 1
| 0.00 3.00 1 0.00 3.00 1 35.06 T 3.00 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 6, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 9, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 31.04 22.17 1 114.02 11.08 1
| 0.00 0.00 1 0.00 0.00 1 0.00 T 0.00 1
| MIN. -32.80 0.00 1 -72.63 0.00 1
| 0.00 22.17 1 0.00 22.17 1 0.00 T 22.17 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 10, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 36.29 3.00 1 0.04 0.00 1
| 0.00 0.00 1 0.00 0.00 1 35.07 T 0.00 1
| MIN. 27.66 0.00 1 -95.86 3.00 1
| 0.00 3.00 1 0.00 3.00 1 35.07 T 3.00 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 11, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 0.00 0.00 1 -72.63 17.67 1
| 0.00 0.00 1 0.00 0.00 1 32.80 C 0.00 1
| MIN. 0.00 17.67 1 -72.63 0.00 1
| 0.00 17.67 1 0.00 17.67 1 32.80 C 17.67 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 12, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 0.00 0.00 1 72.63 17.67 1
| 0.00 0.00 1 0.00 0.00 1 32.80 C 0.00 1
| MIN. 0.00 17.67 1 72.63 0.00 1
| 0.00 17.67 1 0.00 17.67 1 32.80 C 17.67 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 13, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 16.80 11.67 1 -46.85 5.83 1
| 0.00 0.00 1 0.00 0.00 1 18.03 C 0.00 1
| MIN. -16.80 0.00 1 -95.86 0.00 1
| 0.00 11.67 1 0.00 11.67 1 18.03 C 11.67 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 14, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. -27.64 3.00 1 0.05 3.00 1
| 0.00 0.00 1 0.00 0.00 1 35.06 T 0.00 1
| MIN. -36.28 0.00 1 -95.84 0.00 1
| 0.00 3.00 1 0.00 3.00 1 35.06 T 3.00 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 15, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 16, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. -13.40 3.00 1 0.04 3.00 1
| 0.00 0.00 1 0.00 0.00 1 53.10 T 0.00 1
| MIN. -22.04 0.00 1 -53.12 0.00 1
| 0.00 3.00 1 0.00 3.00 1 53.10 T 3.00 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 19, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. -13.40 3.00 1 0.05 3.00 1
| 0.00 0.00 1 0.00 0.00 1 53.09 T 0.00 1
| MIN. -22.04 0.00 1 -53.12 0.00 1
| 0.00 3.00 1 0.00 3.00 1 53.09 T 3.00 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 21, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. 16.80 11.67 1 -46.85 5.83 1
| 0.00 0.00 1 0.00 0.00 1 18.03 C 0.00 1
| MIN. -16.80 0.00 1 -95.85 11.67 1
| 0.00 11.67 1 0.00 11.67 1 18.03 C 11.67 1
|---------------------------------------------------------------------------
|---------------------------------------------------------------------------
| MAX/MIN FORCE VALUES FOR MEMB 22, AMONGST ALL SECT LOCATIONS
| FY/ DIST LD MZ/ DIST LD
| FZ DIST LD MY DIST LD FX DIST LD
|
| MAX. -27.65 3.00 1 0.04 3.00 1
| 0.00 0.00 1 0.00 0.00 1 35.07 T 0.00 1
| MIN. -36.29 0.00 1 -95.85 0.00 1
| 0.00 3.00 1 0.00 3.00 1 35.07 T 3.00 1
|---------------------------------------------------------------------------
52. FINISH
************************************************************
* For questions on STAAD.Pro, please contact *
* Research Engineers Offices at the following locations *
* *
* Telephone Email *
* USA: +1 (714)974-2500 support@reiusa.com *
* CANADA +1 (905)632-4771 detech@odandetech.com *
* CANADA +1 (604)629 6087 staad@dowco.com *
* UK +44(1454)207-000 support@reel.co.uk *
* FRANCE +33(0)1 64551084 support@reel.co.uk *
* GERMANY +49/931/40468-71 info@reig.de *
* NORWAY +47 67 57 21 30 staad@edr.no *
* SINGAPORE +65 6225-6015/16 support@reiasia.net *
* INDIA +91(033)2357-3575 support@calcutta.reiusa.com *
* JAPAN +81(03)5952-6500 eng-eye@crc.co.jp *
* CHINA +86(411)363-1983 support@reiasia.net *
* *
* North America support@reiusa.com *
* Europe support@reel.co.uk *
* Asia support@reiasia.net *
************************************************************
Table 4B Reference Design Values for Visually Graded Southern Pine Dimension
Lumber (2" - 4" thick)1,2,3,4,5
(Tabulated design values are for normal load duration and dry service conditions, unless specified
otherwise. See NDS 4.3 for a comprehensive description of design value adjustment factors.)
Table 4D Reference Design Values for Visually Graded Timbers (5" x 5" and larger)1,3
(Cont.) (Tabulated design values are for normal load duration and dry service conditions, unless specified
otherwise. See NDS 4.3 for a comprehensive description of design value adjustment factors.)