CASE STUDY

3D crane boom survey and ASSET Jack-up

structural integrity analysis LOCATION UK and Singapore


DATE 2016

Thorough analysis of
the actual structural
integrity of your cranes
can help you make
significant savings when
your OEM conditions
state replacement is the
only option

BENEFITS

Provided a cost effective solution

Engineered solution which complied with


legislative requirements

No crane and operational down time

Work scope completed ahead of time

DELIVERY ASSURED
CHALLENGE SOLUTION SUMMARY

Following a Non-Destructive Testing (NDT) • We created a 3D Finite Element Analysis • The cost of doing this analysis was • Survey of inaccessible crane
inspection on the three pedestal cranes on (FEA) model of each of the three crane significantly lower than the replacement structures using 3D laser
board the jack up rig, it was found that all booms based on the available information costs for all three cranes. scanning and rope access
three booms had surface corrosion covering and the 3D scan. Even though the cranes • Should any of the crane booms have failed surveyors
over 50% of their total surface areas. A were the same make and model, all three the analysis due to over utilisation, Sparrows • FEA
criterion set by the crane manufacturer states booms were configured differently. The could issue the customer with de-rated load • Remedial recommendations
that if surface corrosion exceeds 50% of the booms where analysed in accordance with curves based on the current state of the • Technical support
total surface area of the boom, replacement American Petroleum Institute (API) Spec crane booms along with remedial local repair • Project management
is required and as a result, all three booms 2C in the un-corroded condition in order options to take to bring the boom back to its
where condemned by the manufacturer with a to obtain baseline member utilisations for full safe working load.
replacement cost totalling $2.25 million dollars. comparison.
This criterion does not take into account the • The boom models were then modified to
wall thickness loss due to the corrosion. simulate all relevant corrosion on each of the
crane booms and analysed using the same
Due to the high replacement costs the design loads.
customer wanted a second opinion and • The highest utilised members of each crane
contracted Sparrows Group to perform a boom was then compared against their
survey on each of the three cranes using respective un-corroded utilisations along
3D laser scanning and rope access trained with the utilisations of each corroded
surveyors. This scan would then allow us to member and the elements surrounding the
perform a structural analysis and determine corroded members. This formed a clear
1. 2.
what effect the corrosion was having on the picture of how the corrosion affected the
structural integrity of the booms. The aim structural integrity of each of the three
of the study was to confirm if the corroded booms. In this case the corrosion had no
crane booms were still compliant with relevant major effect on the structural integrity of
design codes and whether or not remedial any of the three crane booms. The utilisation 1.
repair work would suffice. increases were minimal and all corroded Corrosion
members utilisations remained below 100% found on one
when measured against the requirements of the crane
of API 2C. Therefore, all three crane booms booms
where deemed suitable to continue service
at full capacity. 2.
FS2000 model
of crane boom

Please visit www.sparrowsgroup.com/contact to find your nearest office

© Copyright Sparrows Offshore Group Limited. All rights reserved.


11501cs10 November 2016