Rangka Atap

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 11

a Atap

Bentang Kuda-Kuda = 2.25 m


Jarak Kuda-Kuda = 2.7 m 6000 mm
Jarak Gording = 1.4 m
o
Sudut Kemiringan Atap = 44
Profil Gording C.125.65.6.8
Berat Gording 13.4 kg/m
Modulus Elastisitas (E) = 200000 Mpa
Modulus geser ( G ) = 80000 Mpa
Poisson ratio ( m ) = 0.3
Koefisien muai ( at ) = 1,2 x10-6 / ºC (pasal 5.1.3, SNI 03- 1729- 2002, hal 9
=
Mutu baja = BJ 37
Berat per Unit Volume Baja = 7850 kg/m3
Tegangan leleh ( fy ) = 250 Mpa
Tegangan Ultimit ( fu ) = 410 Mpa
Peregangan minimum = 0.2
Penutup atap Genteng = 50 kg/m2
Berat Gording = 13.4 kG/m2
Plafond eternit + penggantung = 18 kg/m2 (PPPURG 1987, hal 6 )
Beban hidup gording = 100 kg
Beban air hujan = 24 kg/m2 (PPPURG 1987, hal 7 )
Tekanan tiup angin = 25 kg/m2 (PPPURG 1987, hal 18 )

1 Perhitungan Gording
C 125.23.5.6 Satuan
d atau ht 125 mm
bf 23 mm
tw 5 mm
tf 6 mm
r 1.94 mm
A 2140 mm2
Ix 4250000 mm4
Iy 655000 mm4
rx 49.9 mm
ry 19.6 mm
Sx 68000 mm3
Sy 14400 mm3
Zx 32383.25 mm3
Zy 2293.25 mm3
J 8270.33333333333 mm4
Cw 2318863750.00 mm6
h 109.12 mm

2 Pembebanan Gording
a. Beban Mati
Beban Penutup Atap = 70 kg/m
Berat Gording = 13.4 kg/m
Berat trackstang (10% x Berat Goring kg/m) = 1.34 kg/m
Jadi total beban mati (q) = 84.74 kg/m

B. Beban Hidup
Beban Hidup Pekerja = 100 kg/m2
Beban Air Hujan = 45.36 kg
c. Beban Angin
Tekanan tiup angin = 25 kg/m2
o
Kemiringan Atap 44
Koefisien Angin
Angin Tekan (0,02 α - 0,4) = 0.48 (pasal 2.1.3.3,PPPURG1987, hal 20)
Angin Hisap (-0,4) = -0.4
Beban angin :
Beban angin tekan (Wty) = 16.8 kg/m
Beban angin hisap (Why) = -14 kg/m

3 Momen Akibat Pembebanan Gording


a. Beban Mati (D)
q = 84.74 kg.m
Jarak Antar Kuda-Kuda (L) = 2.7 m
qx (q sin α) = 1.50006113343275 kg.m
qx (q Cos α) 84.7267219748054 kg.m
Mx = (1/8 . qx . L2 ) 0.94925743600041 kg.m
My = (1/8 . qy . L2 ) 53.6161287496815 kg.m
b. Beban Hidup (L)
Beban Hidup Pekerja
P=L = 100 Kg
Jarak Antar Kuda Kuda (L) = 2.7 m
Px= P sin α = 1.77019251054136 kg
Py= P cos α = 99.9843308647691 kg
Mx = (1/4 .Px .L) = 0.995733287179514 kg.m
My = (1/4 .Py .L) = 56.2411861114326 kg.m
Beban Hidup Air Hujan
P=L = 45.36 kg
Jarak Antar Kuda Kuda (L) = 2.7 m
Px= P sin α = 0.80295932278156 kg/m
Py= P cos α = 45.3528924802593 kg/m
Mx = (1/4 .Px .L) = 0.451664619064628 kg.m
My = (1/4 .Py .L) = 25.5110020201458 kg.m
Jadi jumlah beban hidup pekerja dan beban hidup air hujan adalah:
Px total = 2.57315183332292 kg.m
Py total = 145.337223345028 kg.m
mx total = 1.44739790624414 kg.m
my total = 81.7521881315785 kg.m

c. Beban Angin
WWty = (1/8 .Wty . L2) = 15.309
MWhy = (1/8 .Why . L2 ) = -12.7575

4 Kombinasi Pembebanan Atap


1U = 1,4D
Ux = 1.32896041040057 kg.m
Uy = 75.0625802495541 kg.m
2U = 1,2 D + 0,5 La
Ux = 1.86280787632256 kg.m
Uy = 105.215448565407 kg.m
3U = 1,2 D + 1,6 La + 0,8 W
Ux = 16.8949455731911 kg.m
Uy = 183.942855510143 kg.m
4U = 1,2 D + 1,3 W + 0,5 L
Ux = 23.7585788977375 kg.m
Uy = 90.1655173995084 kg.m
5U = 0,9 D ± 1,3 W
Ux = 22.6943316924004 kg.m
Uy = 66.4545158747134 kg.m
(pasal 6.2.2, SNI 03- 1729- 2002, hal 13)
Jadi Mux max = 23.7585788977375 kg.m
= 237585.788977375 n.mm
Jadi Muy max = 183.942855510143 kg.m
= 1839428.55510143 n.mm

5 Kontrol Kekuatan Profil


a. Kontrol Kelangsingan Penampang
Asumsi : Penampang Kompak bila λ < λp
Penampang Tidak Kompak bila λp < λ ≤ λr
Penampang Langsing λ > λr

Sayap = = 3.83333333333333
𝜆=√(𝑏/𝑡𝑓)

Badan = = 3.83333333333333
𝜆=√(𝑏/𝑡𝑓)
Sayap = λ = 500√Fy = 31.6227766016838 Penampang Kompak
λr = 625/√Fy = 39.5284707521047
Badan = λ = 1680√Fy = 106.252529381658 Penampang Kompak
λr = 2250/√Fy = 142.302494707577
Syarat
1. Sayap = λ < λp “Penampang Kompak”
(Tabel 7.5-1 SNI 03 – 1729 – 2002, hal 31)
2. Badan = λ < λp “Penampang Kompak”

Sayap = λp = = 31.678 Penampang Kompak


1,12√(𝐸/𝐹𝑌)

λr = = 39.598
1.4√(𝐸/𝐹𝑌)

Sayap = λp = = 63.357 Penampang Kompak


2.42√(𝐸/𝐹𝑌)

λr = = 4560.0
5.7√(𝐸/𝐹𝑌)
Syarat
1. Sayap = λ < λp “Penampang Kompak”
(Tabel B4.1b SNI – 1729 – 2015, hal 20)
2. Badan = λ < λp “Penampang Kompak”
b. Kontrol Terhadap Lendutan
E = 2,0 x 105 Mpa. = 2,0 x 106 kg/cm2
menggunakan asumsi 1 Mpa = 1 N/mm2 = 10 kg/cm2 ,
Momen inersia yang berada pada profil C
Ix = 4250 mm4
Iy = 655 mm4
Akibat Beban Mati

= 0.6821390426 cm

= 0.105129664215062 cm

Akibat Beban Hidup

= 0.003206679240678 cm

= 0.000494205859446 cm

Akibat Beban Angin


fx = 0 cm

= 0.601 cm (Perencanaan Struktur Baja Dengan Methode LRFD, Hal 88)

Kombinasi Lendutan
Fx total = 0.685 cm
Fy total = 0.707 cm
Syarat Lendutan
f timbul < f izin
f timbul = = 0.969 cm
Fijin L/240 = 0.9375 cm
F Ijin
√(>〖F 𝐹𝑥
yang 〖𝐹𝑦〗 ^2 )
Timbul
〗 ^2+ = - (tabel 6.4-1, SNI 03- 1729- 2002, hal 15)

c. Kontrol kuat nominal lentur penampang dengan pengaruh tekuk loka

Dari hasil analisis kelangsingan penampang pada sub bab sebelumnya diketahui bahwa profil yang
digunakan merupakan penampang kompak, maka berlaku :
Mn = Mp Mp = Z x Fy (Pasal 8-2.3, SNI 03- 1729- 2002, hal 36)
Mencari Momen Nominal yang Bekerja pada Profil
Mnx = Zx . Fy = 8095812.5 N/mm2
Mny = Zy . Fy = 573312.5 N/mm2 (Pasal 8-2-1.b, SNI 03- 1729- 2002, hal 35)

Kontrol Terhadap Tegangan Lentur


Mux max = 23.7585788977375 kg.m
= 237585.788977375 n.mm
Muy max = 183.942855510143 kg.m
= 1839428.55510143 n.mm
Faktor Reduksi = 0.9
Mux Max Muy max
+ < 1
ᵩb.Mnx ᵩb.Mny

3.597521061004 < 1 -
(Pasal 11.3.1 , SNI 03-1729-2002, hal 76)
d. Mendimensi Trackstang
Beban Mati qx = 1.50006113343275 kg.m
Beban Hidup Px = 2.57315183332292 kg.m
Jarak Kuda-Kuda = 2.7 m
Total = 6.62331689359134 kg
Penggunan 2 trackstang, maka :
P/3 = 2.20777229786378 kg
= 0.001 cm2

Fbr = 1,25 fn
σ 𝑃/𝐹𝑛 𝐹𝑛 𝑃/σ
= 0.001 cm2
Fbr = 1/4.π.d2

= 0.038 cm
= 0.383 mm
𝑑= √((𝐹𝑏𝑟.4)/π)
Digunakan trackstang 8mm
6 Pembebanan Kuda-Kuda
enutup atap genteng = 50 kg/m2
Berat per unit volume baja = 7850 kg/m3
Plafond eternit = 11 kg/m2
Penggantung = 7 kg/m2 (PPPURG 1987, hal 5 dan 6)
Data beban hidup pada atap gedung yang digunakan sebagai berikut :
Beban hidup pekerja = 100 kg/m2
Beban air hujan = 24 kg
Tekanan tiup angin = 25 kg/m2 (PPPURG 1987, hal 7 dan 8)
Koefisien angin :
Angin tekan = 0.84
Angin hisap = -0.4
a. Akibat Berat Atap
BA = Berat Atap Genteng x Jarak Gording x Jarak Kuda-Kuda
= 189 kg

b. Akibat Berat Sendiri Kuda-Kuda

c. Akibat Berat Sendiri Gording

d. Akibat Berat Plafond


Bp = Beban Plafon x Jarak Kuda-Kuda x Panjang kuda_kuda
= 109.35 kg tidak di input Kedalam aplikasi\

e. Beban Hidup
PPekerja = 100 kg
PAir Hujan = 4.8 kg/m2
= 18.144 kg

f. Beban Angin
1. Angin tekan
Cq = 0,02 α - 0,4 = 0.48 (pasal 2.1.3.3, PPPURG, hal 21)
Angin Tekan Vertikal
W = Cq x sin α x W x jarak gording x jarak kuda-kuda = 0.669132768984633
Angin tekan horisontal
W = Cq x cos α x W x jarak gording x jarak kuda-kuda = 37.7940770668827
2. Angin hisap
Cq = -0.04 (pasal 2.1.3.3, PPPURG, hal 21)
Angin hisap vertikal
W = Cq x sin α x W x jarak gording x jarak kuda-kuda = -0.055761064082053 0.61
Angin hisap horisontal
W = Cq x cos α x W x jarak gording x jarak kuda-kuda = -3.14950642224023 34.64
2. Perhitungan profil WF.150.75.5.7
A. DATA BAHAN
Tegangan leleh baja (yield stress), fy 400 MPa
Tegangan sisa (residual stress), fr 70 MPa
Modulus elastik baja (modulus of elasticity), E 200000 MPa
Panjang Kuda-Kuda Lb 3500 m
Modulus elastik geser baja G 77200 MPa
Angka Poisson (Poisson's ratio), u 0.3

B. DATA PROFIL BAJA


Profil Baja WF 150.75.5.7 Satuan
d atau ht 150 mm
bf 75 mm
tw 5 mm
tf 7 mm
r 8 mm

tf A
Ix
1785
6660000
mm2
mm4
Iy 695000 mm4
rx
tw 61.1 mm

h h2 ht ry
Sx
16.6
88000
mm
mm3
Sy 132000 mm3
Zx 98195 mm3

r Zy 20537.5 mm3
h1 Cw
J 23108.3333333333 mm4
3553013750 mm6
bf H 120 mm

C NILAI GAYA DALAM PADA SAP

Gaya Dalam kN (absolut) Nmm


Pu -34.894 34894
Mux -236.37 236370000
Muy 223.7 223700000
VU 4.797 4797

D KONTROL PENAMPANG PROFIL


Cek sayap

0,38 √(Es/fy) λ = 0,56√(𝐸𝑠/𝑓𝑦)


𝑏𝑓/( 2𝑡𝑓)
5.35714285714286 ≤ 12.5219806739988 Non Langsing

Cek badan

24.000 ≤ 33.3174 Non Langsing

h/( tw) 1,49 √(𝐸𝑠/𝑓𝑦)


E PENENTUAN FAKTOR EFEKTIF
K = 1 Diasumsikan bahwa nilai K adalah 1

F PENENTUAN TEGANGAN KRITIS TEKUK-LENTUR (Fcr)


Fe =

Fe = 44.4027459390071 MPa
Tegangan kritis, Fcr harus ditentukan sebagi berikut ini :
≤ 2.25 maka Fcr =

Atau
≥ 2.25 maka Fcr = 0,877Fe

9.00845187704048 ≥ 2.25
maka Fcr = 9.21630208856032 MPa
PAKAI OPSI 2

G PENENTUAN TEGANGAN KRITIS TEKUK-PUNTIR (Fcr)


Fe =

Fe = 320.392001688808 Mpa
Tegangan kritis, Fcr harus ditentukan sebagi berikut ini :
≤ 2.25 maka Fcr =

Atau
≥ 2.25 maka Fcr = 0,877Fe
1.24847061690545 ≤ 2.25 maka Fcr = 237.203100043822 MPa
Pakai Opsi 1
H PENENTUAN GAYA TEKAN NOMINAL
CATT Jika Fcr tekuk lentur < Fc tekuk puntir maka tekuk yang terjadi tekuk -lentur
Fcr = 237.203100043822 Mpa
Pn = Fcr x Ag
= 423407.533578222 N
qcPn = 381066.7802204 N
Cek rasio struktur
Pu
Rasio = = 0.091569251929591 ≤ 1
qcPn
Memenuhi Syarat

I PENENTUAN MOMEN NOMINAL AKIBAT TEKUK LATERAL


Mn = Mp = FyZx
MParah x = 39278000 Nmm
= 39.278 kNm

Lp =

Lp = 653.289620306339 mm

rts = atau

rts = 19.8431348329844 mm
J = 23108.3333333333 mm4
C = 1
ho = d-tf
ho = 143 mm

Lr =

Lr = 2763.86520887997 0.001836326552236 0.00000337 0.0000132


= 2763.86520887997 0.001836326552236 0.004076971327646
= 2763.86520887997 0.076897970583634
= 2125.35625529581 mm
Tekuk torsi lateral harus ditentukan sebagai berikut:
Lb ≤ Lp Keadaan batas dari tekuk torsi-lateral tidak boleh digunakan
Lp < Lb ≤ Lr maka nilai akan menggunakan rumus

Mn =
Lb > Lr
Mn = FcrSx ≤ Mp
Lp = 653.289620306339 mm
Lb = 3500 mm
Lr = 2125.35625529581 mm

Cb =
Keterangan
Mmaks = nilai mutlak maksimum dalam segmen tanpa dibreising (Nmm)
MA = nilai mutlak momen pada titik seperempat dari segmen tanpa dibreising (Nmm) 152070300
MB = nilai mutlak momen pada sumbu segmen tanpa dibreising (Nmm) 88589400
MC = nilai mutlak momen pada titik tiga-perempat segmen tanpa dibreisiing (Nmm) 57103400
Cb = 1.81441692702238
Mn =
Mnx = 86455695.3037278 nmm
Mnx >< Mpx
86455695.3037278 >< 39278000
Mnx pakai = 39278000 nmm
qbMnx = 35350200 nmm
Mny = Fy.Zy
Mny = 8215000 nmm
qbMny = 7393500 nmm

J KONTROL TERHADAP INTERAKSI GAYA TEKAN DAN LENTUR


Rasio tegangan aksial
Pu 348940
= = 0.915692519295913
qPn 381066.7802204
Kondisi
Pu ≤
< 0.2 maka 1
qPn
𝑃𝑢/█( @2𝑃𝑛) +
Pu (𝑀𝑢𝑥/█( @𝑀𝑛𝑥 ≤
≥ 0.2 maka 1
qPn )+
𝑃𝑢/█(
𝑀𝑢𝑦/█(@∅𝑃𝑛)
@𝑀𝑛𝑦)+
8/█(
) @9)
(𝑀𝑢𝑥/█( @𝑀𝑛𝑥) +
𝑀𝑢𝑦/█( @𝑀𝑛𝑦) )
𝑃𝑢/█( @2𝑃𝑛) +
(𝑀𝑢𝑥/█( @𝑀𝑛𝑥
)+
𝑃𝑢/█(
𝑀𝑢𝑦/█(@∅𝑃𝑛)
@𝑀𝑛𝑦)+
Sehingga 8/█(
) @9)
Berdasarkan perhitungan
maka 0.916 ≤ (𝑀𝑢𝑥/█( @𝑀𝑛𝑥)
1 + maka akan dipakai
𝑀𝑢𝑦/█( @𝑀𝑛𝑦) )
Opsi 1
AMAN PAKAI OPSI 2

maka 0.916 ≤ 1
Opsi 2
AMAN

K CEK SAFETY FACTOR (SF)


qPn
SF = = 1.092 ≥ 1
Pu
AMAN

3. Perhitungan Profil C.125.23.5.6


A. DATA BAHAN
Tegangan leleh baja (yield stress), fy 400 MPa
Tegangan sisa (residual stress), fr 70 MPa
Modulus elastik baja (modulus of elasticity), E 200000 MPa
Panjang balok Lb 8000 m
Modulus elastik geser baja G 77200 MPa
Angka Poisson (Poisson's ratio), u 0.3

B. DATA PROFIL BAJA


C 125.23.5.6 Satuan
d atau ht 125 mm
bf 23 mm
tw 5 mm
tf 6 mm
r 1.94 mm
A 2140 mm2
Ix 4250000 mm4
Iy 655000 mm4
rx 49.9 mm
ry 19.6 mm
Sx 68000 mm3
Sy 14400 mm3
Zx 32383.25 mm3
Zy 2293.25 mm3
J 8270.33333333333 mm4
Cw 2318863750.00 mm6
h 109.12 mm

C NILAI GAYA DALAM PADA SAP 2000

Gaya dalam kN (Absolut) Nmm


Mumax 28.8 28800000
Vu maks 32.9 32900

D KONTROL PENAMPANG PROFIL


Batasan penampang kompak, tak kompak dan langsing adalah
1 Penampang kompak l < lp
2 Penampak tak kompak lp < l < lr
3 Langsing l > lr
Cek sayap Maka Termasuk Penampang

l = = 1.91666666666667 Penampang Kompak


𝑏𝑓/( 2𝑡𝑓)

lp = 0,38√(𝐸𝑠/𝑓𝑦) = 8.4970583144992 -

lr = = 22.3606797749979 -
1,0√(𝐸𝑠/𝑓𝑦)

Batasan Kondisi 1 - -

Cek badan Maka Termasuk Penampang

l =
ℎ/( 𝑡𝑤) = 21.824 Penampang Kompak

lp = 3,76 √(𝐸𝑠/𝑓𝑦) = 84.0761559539921 -

lr = 5,7√(𝐸𝑠/𝑓𝑦) = 127.455874717488 -

Batasan Kondisi 1 - -
E PENENTUAN MOMEN NOMINAL AKIBAT TEKUK LATERAL
Karena penampang profil kompak maka
Mn = Mp = FyZx
Mp = 12953300 Nmm
Mp = 12.9533 kNm

Kontrol local torsional buckling


Lp =

Lp = 771.354009518328 mm

r2ts =
("0,38"
√(𝐼_𝑦
Atau 𝐶_𝑤 ))/𝑆_𝑥
rts =

rts = 5.15492368577592 mm
J = 8270.33333333333 mm4
C = 1
ho = d-tf
ho = 119 mm

Lr =

Lr = 718.007227661645 0.001022038227056 1.04456213756281E-06 0.00001325


= 718.007227661645 0.001022038227056 0.003780762110681
= 718.007227661645 0.069302239052838
= 497.595085330731 mm
Tekuk torsi lateral harus ditentukan sebagai berikut:
Lb ≤ Lp Keadaan batas dari tekuk torsi-lateral tidak boleh digunakan
Lp < Lb ≤ Lr maka nilai akan menggunakan rumus

Mn =
Lb > Lr
Mn = FcrSx ≤ Mp
Lp = 771.354009518328 mm
Lb = 8000 mm
Lr = 497.595085330731 mm
Lp = 771.354009518328 mm
Lb = 8000 mm
Lr = 497.595085330731 mm
Maka masuk dalam kondisi 2
Cb =
Keterangan
Mmaks = nilai mutlak maksimum dalam segmen tanpa dibreising (Nmm)
MA = nilai mutlak momen pada titik seperempat dari segmen tanpa dibreising (Nmm)
MB = nilai mutlak momen pada sumbu segmen tanpa dibreising (Nmm)
MC = nilai mutlak momen pada titik tiga-perempat segmen tanpa dibreisiing (Nmm)
Cb = 2.203
Mn =
Mn = -1107567267.1058 nmm
Mn >< Mp
-1107567267.10577 = 12953300
Mn pakai = 129533000

𝑀𝑢/(Φ𝑏 𝑥
Rasio momen =
𝑀𝑛) ≤ 1

Rasio momen = 0.24704129449638 ≤ 1


Aman
𝑀𝑢/(Φ𝑏 𝑥
𝑀𝑛)

F KAPASITAS GESER PENAMPANG

l = ≤
2,24√(𝐸𝑠/𝑓𝑦) untuk profil I canai panas

21.824 ≤ 50.0879226959953

Kn = 5+ = 5.000930248
5/
maka (( 〖𝐿𝑏 = 55.0051161260478
/𝑑) 〗 ^ 1,1 √((𝑘𝑛 untuk profil simetris ganda
l = ≤
dan simetris tunggal
2) 𝑥 𝐸𝑠)/𝑓𝑦)

21.824 ≤ 55.0051161260478
Aman
Maka kuat geser nominal
Vn = 0,6FyAwCv Nilai Cv = 1
Vn = 150000 N

Vn = Penentuan nilai kuat geser ada pada SNI


150 kN 1729:2015 halaman 73

Cek rasio geser

Rasio geser = 𝑉𝑢/(Φ𝑠 𝑥 ≤ 1


𝑉𝑛)
Dengan nilai reduksi lentur Φb = 0,9
0.2437037037037 ≤ 1
Rasio geser =
Aman

G KONTROL INTERAKSI GESER LENTUR

Pemeriksaan interaksi = 𝑀𝑢/(Φ𝑏 𝑥 𝑀𝑛) + 0,625 ≤ 1.375


x 𝑉𝑢/(Φ𝑠 𝑥 𝑉𝑛)
0.40544870190379 ≤ 1.375
Aman

K CEK SAFETY FACTOR (SF)


Momen
qMn
SF = = 4.04790625 ≥ 1
Mu
AMAN

Geser
qVn
SF = = 4.10334346504559 ≥ 1
Vu
AMAN
Procil c.125.23.5.6 ( Gording )
P V2 M3
KN KN KN-cm
min -4.208 -0.308 -50.07
max -0.522 0.329 28.8

Baja Wf 150.75.5.7
P V2 M3
KN KN KN-cm
min -34.894 -4.753 -236.37
max -0.321 4.797 223.7

You might also like