Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

INDUSTRIAL GEA.

923OD

General Electric lt G l

o x2o9 HIGH MAST LUMTNATRES


SYMMETRICAL & ASYMMETRICAL OPEN OR ENCLOSED

The General Electric High Mast luminaire is available e;ther open or enclosed wilh symmetrical or
asymetrical optical assembly. The symmelrical opt:cal is designed for general interchange and park"
ing lot area lighting while asymmetrical optical is used for improved lighting of straight sections ol
roadways. The open units are self-ventilated and the enclosed units are charcoal.iiltered for maximum
efficiency over the life of the luminaire. Both open and enciosed Iuminaires feature reflectors with
ALGLAS" -f,nish for long life!

A newly-designed luminaire for


elf ic!ently lighting interstate
highways, inte.changes and park-
ing lots. Available either open or
enclosed with symmeirical or
asymmetrical optical assembly.

HIGH MAST LUMINAIRE FEATU R ES i

LRellector -^ ,^ rilr p
form,.d alLrr nL]lf opl mLrm efi cr--ncy
c ,oanab I ty ana rnarnta n,.d photo
metr cs h gh y irn forrri ghr d slrrblt on
palle rn
Open, Ventilated Version for rrghcsl
n lra opt ca -.lf c ency v,, ih vcni lalrof
paov d-.ai by a r sv/ept !p,.!ard by amp
hcat I r4-. *
Enclosed, Gasketed, Fillered Version i l4F .'
tor h ghcst m arnta n{rd opl ca eff
c encv \,! lh heat and shock res stant ENC LOSED
lcmpcrcd !l ass !lloba s rconc rubber
qasket io assur-. long- f-. seal of optr
nl, ,r r' . n | ^ir "r-
brealhes thro!gh acl vated charcoa
i tcr
Wide Variety of Photomelric Distribu-
tions. T!/o reflectors to arbta n a drs-
f.ibut ons by chang ng sock-.t pos tror-l
one r-.f -.ctor f or Typ-. V syn]metric drs-
trbrtons wth max cp irom 55'r thrLr
70' on-o ret erctor ior a asyflmetr ca
d strbL I ons
2. Cast Aluminum Ballast and Slipfitter Mount - S ng e a umrnuTn for eve ng rimnare settng ol i 3'r vcrtca Dogscrcwand
casting to which a I ba ast componcnts. s ipfitter and ref ector clarnp to gr p p pe to prevenl tw st ng of um na rc on brackcl
assernbly are mo!nted n heavy wrnds
3. Latching Fasi access w thout too s to a I opt ca an,:J ba ast 6. Ballast Construction - Co s are DTcc s on wound on molded
compon,6nts w th sta nlcss stee latchandcampband Ouckds bobbins assembled on a we ded coTe of srLicon steel. and m
connect -olectr cal plug pcrm ts easy remova and nstallalron of pregnated \,r' th modil ,.d'po yester res n for long life
opt ca assembly 7. Terminal Board - Molalcd phcnol c wrth barriers io preve nl acc -
4, Lamp Support - For max mLrrn amp protect on lrom vr d,.ntal sh orts Accoma.odates w rc s zes *6 lo +18
brat on damage. an insu atcd w re larnp sLrpport is ntegra lvilh 8. Wind Loadinq Effeci vc projcctcd area oi 2 0 Sq ft
th,. socket slrpport stTucture on a 1000W units
5. Sliplitter - Accomrnodates 2 standard p pe w th adiustm,.nr

.a lle!isrNnra Ir.demrrk ol General El€cLr c Compa.y

GEilERAT @ TTECTRTC
HIGH MAST GUIDE FOBM SPECIFICATIONS DIM EN S ION S
Luminaire wilL be a General Electric Type X209 High Masl, Cat.
No. {specifyl. The lumina re will consisl of a cast aluminum ballast
and slipfltter mounting plate, a hydrofo.med aluminum ballast 6.5',
cover, a spun and faceted aluminum reflector assembly, and when
requjred, a tempered glass door.
All ballast components will be accessible from the top wiih the
lumina re mounted and aimed The sliplitter will be capable of
adjustment in two directions independenlly, side to side and iront
to back. The slipfitter will be suitable for 2 horizontal
pipe tenon mounting and will be adjustable a 30 for leveling.
A dog po:nt set screw with drill bushing will be included to prevent
twistlng of the luminaire on the bracket.
The ballast will be electrically connected to the optlcal assem-
bly by a pre-wired quick disconnect plug A pre-wired terminal
board shail be provided requiring only connection of the power
supply leads.
ii
The reflector wllt be spun from aluminum sheet, faceted to re-
direct reflected light away from the iamp arc tube, and iinished it
with the ALGLAST, process. The reflector assembly wiil be {open
bottom and ventiialed) or (enclosed and charcoal-filiered).
I
L

OPEN . SYMM ETR ICA L OPEN . ASYMMETR ICAL


ITIDUSTRIAL
SAZAArOUS
_i!eq-,r.19!:l!9
_ AAEA
sOADWAY
coirMEncrAl

HIGH MAST CATALOG NO. EXAMPLE

Construclion

V Opcn Vent ated lnsert des red lnserl des rcd two
C = Closed and F rercd lvl Metal Hal de Singedqt d gil code - see
H lvlercury 1 124 availability tab e
2=248
3=244
4 277
5 480
AVAILA BILITY
PHOTOMETR C CURVE NIJMBEFS (3s I Txxrxl
tEs
1000 LU

6318
r/l c.V ia) li289 i)
Mat I 67 5 6150*
Ta)
t: Lr:l
MC V ts.1
ORDERING IN FOR N/ATION
For over €ight luminaires per r ng,
Select approprate base catalog nLrrnber frorn table below and use on V 480 V lu..inair-"s.
nsert desired voltage i*l and beam type (...,..) d glts to I na ze
cata oq numbcr before orderinq Vertica angle ol maxlrn!m cand epower is 70'
Base Catalog No. Net. Wt. (Lbs.) Conlact faclory for availabi ty.
Open tlxtures Sym. Asym- NA

400 watt Luca ox


X209V 401'.r,-r, 44 47
I000 watt L!calox
X209V I 0L'..-.. 45 48
1000 watt meta ha ide
X209V I 0N/ 44 47
Enalosed/Fillered
^,., Sym, Asym.
400 wait LLrca ox
X2O9C 40 L. r.r, 53 56
1000 watl LLrcalox
X209C T 01. 54 57
1000 watt meta ^^
halide
X209C 1 0M" l..r, 53
"lndrcates ballast vo tage lnsert s ngle dlgit for cles red vo tage
from tab e n Cai No exarnple
,..... lnd cates photometric d stribul on nsert doLrb e dig t for de-
s red type from tab e in Cat. No exarap e

OPTIONS
Sleadilux ballast
Fuses or Double
- SPEngle
lndividual Receptacle op ta 277V
ACCESSORTES
Decorative Shroud
- C245G010
External Light Shjeld C245G009
-
MOUNTING
Eff. Proj. Area 2.0 sq. ft.
-
(,
?AT'O T]F IFTANSVTtsSF ! S UT LIZED LUIVIE NS PERCENT
ul ql -I :^
-.r --l

z i<3 t l
oU) (': os a

; -
?
l !
m
F
lo
9Tt
io c
:
io
:-{
I
tr
! r _o N

!=
az --{
6 I.
i Er :9
IE z
1 ;c n
cp
3
-= a)

!
xrn
az 3r) ia m e
=c
1<
ai ; ;ln :
?u!
F
!

: q '
UTILIZEDLUi4ENS PEFCENT
r9R <t
3=;
f I-
o(n 1l o- il
- !
Fl :o
grt 4e ii! <!
==
; io
q
io
:1
6
:al- EX
: i ri-
>t _o
9
<- !z *o
; !l io -{
el
t; L; =:e IF o
r=ll
o
! .n
: r.z=l 3r) +
;q ;t,nf-tr a
I
L =c
1<
;ln
6
o
l1= i t l
I
il, - C
ft
--_-t,
m
o

BAI O OF IRANSVERSE D STANCE TO MOUNTING NE 6I]T LITII IZED LUI\,IENS PEBCENT qq:3<
dq<€ 3

! .h @;;;: i.
tn
F
o
TI -n ii ;i
o
o
-.1
--l
^g
q
o
- (') =
N zB
9 --t 6'O
z, o -
!= 0
r z
6r
;c n1 .) 3
-= c o
co
-.1
:FT s
:t- 4Z
F

ln
]n 6

GENERAL
@ rrrcrnrc
E LECT B IC CON,4PANY
Llghting Systems Department, Hendersonvllle, N.C. 28739 EEiTERAT
283 0sM)H

You might also like