Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 9

附表三:第二批区间路基过轨布置表

设施中心里 过轨布置里

序号 /Facility 程/Mileage of 过轨类型及过轨管根数/ type and number of steel pipe
/index Center communication
steel pipe
Miles

通信:预埋Φ100mm钢管 6根(含防灾
1 DK051+545 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)
DK051+590
通信:预埋Φ100mm钢管 6根(含防灾
2 DK051+615 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

通信:预埋Φ100mm钢管 6根(含防灾
3 DK055+610 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

4 DK055+630 DK055+630 信号:预埋Φ100mm钢管 8根/Signalling: 8 embedded


Φ100mm steel pipes

通信:预埋Φ100mm钢管 6根(含防灾
5 DK055+650 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

通信:预埋Φ100mm钢管 6根(含防灾
6 DK062+880 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)
DK062+900
通信:预埋Φ100mm钢管 6根(含防灾
7 DK062+920 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

通信:预埋Φ100mm钢管 6根(含防灾
8 DK083+330 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

信号:预埋Φ100mm钢管 8根/Signalling: 8 embedded


9 DK083+350 DK083+350 Φ100mm steel pipes

通信:预埋Φ100mm钢管 6根(含防灾
10 DK083+370 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

通信:预埋Φ100mm钢管 6根(含防灾
11 DK101+380 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)
DK101+400
通信:预埋Φ100mm钢管 6根(含防灾
12 DK101+420 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

通信:预埋Φ100mm钢管 6根(含防灾
13 DK108+680 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

14 DK108+700 DK108+700 信号:预埋Φ100mm钢管 8根/Signalling: 8 embedded


Φ100mm steel pipes
DK108+700

通信:预埋Φ100mm钢管 6根(含防灾
15 DK108+720 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

通信:预埋Φ100mm钢管 6根(含防灾
16 DK56+105 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)
DK56+100
通信:预埋Φ100mm钢管 6根(含防灾
17 DK56+130 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

通信:预埋Φ100mm钢管 6根(含防灾
18 DK108+810 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)
DK108+830
通信:预埋Φ100mm钢管 6根(含防灾
19 DK108+850 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

通信:预埋Φ100mm钢管 6根(含防灾
20 DK130+080 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)
DK130+100
通信:预埋Φ100mm钢管 6根(含防灾
21 DK130+120 2)/Communication: 6 embedded Φ100mm steel
pipes (including disaster prevention 2)

1 DK051+540 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根


DK051+590
2 DK051+620 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根
3 DK055+615 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根
DK055+630
4 DK055+645 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根
5 DK062+885 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根
DK062+900
6 DK062+915 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根
7 DK083+335 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根
DK083+350
8 DK083+365 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根
9 GDK101+385 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根
DK101+400
10 GDK101+415 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根
11 DK108+700 DK108+700 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根

12 DIK56+040 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根


DK56+100
13 DIK56+110 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根

14 DK108+830 DK108+830 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根


15 DK130+085 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根
DK130+100
16 DK130+115 电力:预埋Φ150mm钢管 2根;Φ100mm钢管 4根

1 DIK56+100 接触网:预埋Φ150mmHDPE 8根
DK56+100
2 DIK56+550 接触网:预埋Φ150mmHDPE 6根
DK100+150 接触网:预埋Φ150mmHDPE 10根
DK100+150
3 DK100+545 接触网:预埋Φ150mmHDPE 6根
DK108+830 DK108+843 接触网:预埋Φ150mmHDPE 7根
4
5 DK130+100 DK130+195 接触网:预埋Φ150mmHDPE 7根
1 DK56+100 DK56+095 变电:预埋φ100非铁磁性涂塑钢管4根

2 DK100+150 DK100+160 变电:预埋φ100非铁磁性涂塑钢管4根

3 DK108+830 DK108+835 变电:预埋φ100非铁磁性涂塑钢管4根

4 DK130+100 DK130+100 变电:预埋φ100非铁磁性涂塑钢管4根


5 DK142+900 DK142+900 变电:预埋φ100非铁磁性涂塑钢管4根
6 DK144+800 DK144+800 变电:预埋φ100非铁磁性涂塑钢管4根
三:第二批区间路基过轨布置表
上下边坡电缆槽/Up and down 电缆井/Cable well
slope cable trough
个 备注/Note
侧别/Side 个数/Number 型号/model 数/Numb
er

双侧/Both sides 2 I型通信信号电缆井/I-type 2


communication signal cable well
基站/Base station

双侧/Both sides 2 I型通信信号电缆井/I-type 2


communication signal cable well

基站(与中继站合设
I型通信信号电缆井/I-type )/Base station
双侧/Both sides 2 communication signal cable well 2 (co-located with
relay station)

双侧/Left Side 2 II型通信信号电缆井/I-type 2 3号中继站/No.3


communication signal cable well Relay Station

基站(与中继站合设
双侧/Both sides 2 I型通信信号电缆井/I-type 2 )/Base station
communication signal cable well (co-located with
relay station)

双侧/Both sides 2 I型通信信号电缆井/I-type 2


communication signal cable well
基站/Base station
I型通信信号电缆井/I-type
双侧/Both sides 2 communication signal cable well 2

基站(与中继站合设
双侧/Both sides 2 I型通信信号电缆井/I-type 2 )/Base station
communication signal cable well (co-located with
relay station)

II型通信信号电缆井/I-type 5号中继站/No.5
双侧/Both sides 2 communication signal cable well 2 Relay Station

基站(与中继站合设
双侧/Both sides 2 I型通信信号电缆井/I-type 2 )/Base station
communication signal cable well (co-located with
relay station)

I型通信信号电缆井/I-type
双侧/Both sides 2 communication signal cable well 2 基站/Base station

双侧/Both sides 2 I型通信信号电缆井/I-type 2 基站/Base station


communication signal cable well

基站(与中继站合设
I型通信信号电缆井/I-type )/Base station
双侧/Both sides 2 communication signal cable well 2 (co-located with
relay station)

双侧/Both sides 2 II型通信信号电缆井/I-type 2 6号中继站/No.6


communication signal cable well Relay Station
基站(与中继站合设
I型通信信号电缆井/I-type )/Base station
双侧/Both sides 2 communication signal cable well 2 (co-located with
relay station)

双侧/Both sides 2 I型通信信号电缆井/I-type 2


communication signal cable well
牵引变电所/Traction
Substation
I型通信信号电缆井/I-type
双侧/Both sides 2 communication signal cable well 2

I型通信信号电缆井/I-type
双侧/Both sides 2 communication signal cable well 2

AT所/AT POST

双侧/Both sides 2 I型通信信号电缆井/I-type 2


communication signal cable well

双侧/Both sides 2 I型通信信号电缆井/I-type 2


communication signal cable well
AT所/AT POST
I型通信信号电缆井/I-type
双侧/Both sides 2 communication signal cable well 2

双侧 2 电力电缆井 2
基站箱变
双侧 2 电力电缆井 2
双侧 2 电力电缆井 2
中继站箱变
双侧 2 电力电缆井 2
双侧 2 电力电缆井 2
基站箱变
双侧 2 电力电缆井 2
双侧 2 电力电缆井 2
中继站箱变
双侧 2 电力电缆井 2
双侧 2 电力电缆井 2
基站箱变
双侧 2 电力电缆井 2
双侧 2 电力电缆井 2 中继站箱变

双侧 2 电力电缆井 2
牵引变电所
双侧 2 电力电缆井 2

双侧 2 电力电缆井 2 AT所
双侧 2 电力电缆井 2
AT所
双侧 2 电力电缆井 2

双侧 2 电力电缆井 2 牵引变电所

双侧 2 电力电缆井 2 牵引变电所
双侧 2 电力电缆井 2 牵引变电所
双侧 2 电力电缆井 2
双侧 2 电力电缆井 2 AT所

双侧 2 电力电缆井 2 AT所
右 2 Ⅰ型通信信号电缆井 2 牵引变电所

左 2 Ⅰ型通信信号电缆井 2 牵引变电所

左 2 Ⅰ型通信信号电缆井 2 AT所

左 2 Ⅰ型通信信号电缆井 2 AT所
右 2 Ⅰ型通信信号电缆井 2 走行线路基
右 2 Ⅰ型通信信号电缆井 2 动车段路基

业/Profes
sional


信/commun
ication 尽量避开
DK51+551~+609左侧 已修改

信/commun 桩板墙
ication


信/commun
ication


号/Signal
ling


信/commun
ication


信/commun
ication


信/commun
ication


信/commun
ication


号/Signal
ling


信/commun
ication


信/commun
ication


信/commun
ication


信/commun
ication


号/Signal
ling

信/commun
ication


信/commun
ication 尽量避开
DK56+044~+096段右 已修改

信/commun
侧桩板墙
ication


信/commun
ication


信/commun
ication


信/commun
ication


信/commun
ication

尽量避开
电力 DK51+551~+609左侧
桩板墙 已修改
电力 核实过轨里程是否有误
电力
电力
电力
电力
电力
电力
电力
电力
电力

电力 尽量避开
DK56+044~+096段右 已修改
电力 侧桩板墙

电力
电力 与通信过轨冲突
已修改
电力 与通信过轨冲突

尽量避开
接触网 DK56+044~+096段右 已修改
侧桩板墙
接触网 预留综合接地端子2个
接触网 预留综合接地端子2个
接触网 预留综合接地端子2个
接触网 预留综合接地端子2个

接触网 预留综合接地端子2个
变电 预留综合接地端子2个

变电 预留综合接地端子2个

变电 预留综合接地端子2个

变电 预留综合接地端子2个
变电
变电 预留综合接地端子2个

You might also like