PHOENIX CONTACT 53
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Product overview
MINI Analog Supply components, feed-through terminal System cabling, termination carriers Surge protection
Page 64 blocks, marking material Page 88 Page 92 Page 98
For standard signals, setpoint adjusters MACX Analog Ex Supply components, marking material System cabling, termination carriers
Page 150 Page 152 Page 182 Page 184
EMpro energy meters EMpro special function and communication PSK data logger kits PSK compressed air meters
Page 200 modules Page 202 Page 206 Page 208
54 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Product overview
MACX Analog Supply components, marking material System cabling, termination carriers MCR Analog
Page 100 Page 126 Page 128 Page 130
Multiplexers for HART signals Ex i 2-conductor field devices Shield fast connection Test plugs
Page 186 Page 187 Page 191 Page 191
PACT current transformers Test disconnect terminal blocks Current transducers, AC/DC Current transducers, AC
Page 212 See Catalog 3 Page 229 Page 232
Temperature
Temperature transducers Universal
Universal, supplied by an output loop
For resistance thermometers (RTD) 76
For resistance thermometers (RTD), passive
For Pt 100 From 77
For Pt 100, supplied by an output loop 79
For thermocouples 80
For thermocouples, type J and K 81
Temperature head transmitters Universal, supplied by an output loop
Pt 100, supplied by an output loop
Frequency
Frequency transducers Universal 82
Analog frequency transducers 83
Potentiometer/resistor
Potiposition transducers 84
Setpoint potentiometers
Limit values
Threshold value switches Standard analog signals, universal
Standard analog signals 85
Temperature
Digital IN
Isolation amplifiers NAMUR sensors, floating contacts 86
Digital OUT
Solenoid drivers Loop-powered
With line fault detection
Accessories
Configuration Configuration software
Cables 119
Display unit and operator interface, removable
Holder module for display unit and operator interface
Constant voltage source Constant voltage source 87
Setpoint potentiometers
System cabling System components 94
1:1 feed-through terminal block 88
Termination carriers 97
Multiplexers Analog multiplexers 95
Multiplexers for HART signals
Power terminal block/error message modules/
Supply components From 89
T-Connectors/system power supply
Marking material 88
Surge protection 98
Shield fast connection 191
Test plugs
Resistance circuit For line fault detection 183
56 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Selection guide for isolating amplifiers
Isolating amplifiers with Special types of isolating amplifiers Ex i isolating amplifiers with
functional safety - MACX Analog and digital displays functional safety - MACX Analog Ex
109 164
150
151
138
141
112 166
142 188
143 189
144
146
147
139
116 170
146
120 172
124 176
122 174
125 177
123 175
178
From 179
179
149 149
119 149 149
118
118
148
129 184
186
From 126 126
127 127
58 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Basics
Temperature coefficient Ambient temperature range Protective circuit
The temperature coefficient provides an The temperature limits specified here re- In order to protect the measurement and
assessment of the extent to which precision late exclusively to operation. These limits control modules against surge voltages, sup-
deviates when the ambient temperature do not apply to storage and transport. It is pressor diodes are connected upstream of
around an isolating amplifier or measuring here where the temperature limits of the the signal and supply paths. These diodes
transducer changes. In most cases this is materials used are the decisive factor. If the behave in a similar manner to conventional
specified as a percentage. An alternative devices are outside of the specified temper- Zener diodes, except for the fact that sup-
definition is ppm/K (parts per million/Kel- ature range during assembly, they must be pressor diodes have faster response times
vin). Example: brought back within the specified tempera- and a higher maximum current.
250 ppm/K = 0.025%/K. ture range prior to system startup. It is im-
portant to make sure that no condensation
Limit frequency occurs during this process.
Isolating amplifiers are basically designed
to transmit DC signals. However, signal
changes call for a dynamic form of behavior
so that small AC quantities (normally:
30 Hz) can also be transmitted. This is
achieved by defining a limit frequency. At the
same time, a low limit frequency can be
used to suppress higher-frequency AC com-
ponents.
Step response
The step response indicates the response
time of the output signal when an input sig-
Information on directives and stan-
nal step occurs (10 ... 90%). The step re-
dards
sponse is inversely proportional to the limit When carrying out further processing of non-independent items of equip-
frequency. This means that the response ment (components), the applicable regulations pertaining to installation The relevant device-specific regulations also apply with regard to installa-
must be observed. tion in devices.
time decreases as the limit frequency in- (Standards applicable at the time of going to print)
creases. Directives EU International
Environmental tests
Active isolation
POWER POWER
POWER
In the case of modules with this isolation In the case of modules with this isolation Repeater power supplies use the signal in-
method, all components that are connected method, the electronics connected on the put side not only for measured value acqui-
to the input, output or power supply are output side (e.g., the controller) are to be sition, but also to provide the necessary
protected against interference from each protected from interference from the field. power to the passive measurement sensors
other. All three directions (input, output, For this reason, only the input is electrically connected on the input side.
and power supply) are electrically isolated isolated from the output and the power On the output side, they provide a fil-
from one another accordingly. supply that are at the same potential. tered and amplified signal (e.g., from the
The 3-way isolation provides electrical On the input side, the modules need ac- controller).
isolation between the measurement sensor tive signals (e.g., from measurement sen- The isolation method used by these mod-
and the controller as well as between the sors). On the output side, they provide a fil- ules is input isolation.
controller and the actuator. tered and amplified signal (e.g., from the
On the input side, the modules need ac- controller).
tive signals. On the output side, they pro-
vide a filtered and amplified signal.
Power Power I
via signal IN Output IN
via signal
Input signal
Input signal OUT signal OUT RE
Output
signal
Solution:
The modules draw the power needed for The modules draw the power needed for
signal transmission and electrical isolation signal transmission and electrical isolation
from the active input circuit. On the output from the active output circuit, ideally from a I
side, a conditioned current signal is provid- PLC input board that supplies power. RE
ed to the controller or to actuators. On the output side, the loop-powered
This passive isolation allows signal condi- modules operate with a 4 ... 20 mA stan-
tioning (interruption of ground loops) and dard signal. On the input side, the passive
Problem: voltage difference in the ground potential
filtering without an additional power supply. isolator processes active signals.
When this isolation method is used, it is
important to make sure that the active sig-
RE
nal source connected on the output side
(e.g., an active PLC input board) is able to PGround 1 Ground current loop P
Ground 2
supply the passive isolator with power, as
well as operate its load. Solution:
RE
No ground current
PGround 1 loop PGround 2
60 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Basics
Resistance thermometers
Resistance thermometers: Two-conductor connection technology Identical cable lengths and an identical
Resistance change as a function of the temperature
The resistance thermome- i ambient temperature are essential here.
ter is connected to the MCR R L1 Since this is more or less the case in the
10000
Resistance []
-100
100
200
300
400
500
600
700
800
quently distort the result.
Temperature [°C] A distance of 10 m should not be exceed-
ed.
Example: a 50 m long copper cable with a cross section of 0.5 mm2 has
Resistance thermometers (e.g., Pt 100, a specific resistance of 3.4 . A Pt 100 sensor has a resistance change of Four-conductor connection technology
Ni 1000) change their resistance value de- 0.384 per 1 K temperature change. This corresponds to an error of Four-conductor connection technology is
8.8°C.
pending on the temperature. The MCR an ideal connection technology for resis-
temperature transducers detect this change tance thermometers.
and convert it into a proportional analog The measurement result is affected nei-
signal. ther by cable resistances nor by their tem-
To avoid unwanted self-heating of the Three-conductor connection technology perature-dependent fluctuations. The volt-
sensor, the constant measured current Three-conductor technol- i age drop on the supply and return lines can
used is kept as low as possible ogy is normally used to mini- R L1
therefore be measured and compensated
(MCR-T-UI... 250 A). mize the effect of cable resis- for separately. Line compensation is not
R L2
tances. An additional cable is R L3 necessary.
connected to the resistance
thermometer, so that the latter can be mea-
sured using two measuring circuits, one of
which acts as a reference. In this way, it is
possible to compensate for the cable resis-
tance.
Thermocouples
Thermocouples: If the same temperature Fe Therefore, only the difference in the ther-
Thermocouple voltage change as a function of the temperature Cu
prevails at the measuring mal voltages between constantan (Cu-Ni)
junction (1) and the cold and iron is of relevance.
Thermocouple voltage [mV]
80
Typ E Cu
Typ J
junction (2), no current will CuNi A role is also played by the temperature
60
Typ K flow because the generated at the terminal point. If it is known, the tem-
Typ N
40
partial voltages cancel each other out. How- perature at the measuring junction can be
ever, if the temperatures at the measuring derived by adding the thermal voltage mea-
Typ R
20 Typ T junction and the cold junction are different, sured at the same junction.
Typ S
Typ B different voltages are produced. These volt- The MCR temperature transducers for
0
ages do not completely cancel each other thermocouples therefore detect the tem-
out, and so current flows. perature at the terminal points and com-
0
-200
200
400
600
800
1000
1200
1400
1600
1800
Temperature [°C]
A thermocouple therefore always mea- pensate this value, which is also referred to
sures only one temperature difference. This as the reference junction or the cold junc-
In contrast to resistance thermometers, is derived from the difference between the tion.
thermocouples are active sources that gen- thermal voltages at the measuring junction This process is sometimes called cold
erate a voltage in the microvolt range. The and at the cold junction. junction compensation.
temperature difference measured between The voltage produced by the thermoelec-
the measurement junction and the cold tric effect is very low; only a few microvolts
junction is converted into an absolute tem- per Kelvin.
perature with the help of cold junction Example: if a type J thermocouple (FE-CuNi) is connected to a copper
terminal block, thermal voltages with opposite polarity will be generated
compensation. (at the iron-copper and copper-constantan transitions) and cancel each
other out.
Operating principle:
If different metals are joined together, a
thermal voltage is produced in the metal at-
oms as a result of the different binding en-
ergies of the electrons. This voltage is de-
pendent firstly on the metals themselves
and secondly on the temperature.
Digital displays
Use of the freely programmable l/min) to the total flow integrated in the Application:
Pressure measurement and display on MCR-SL-D-U-I
characteristic curve background, which can be displayed in any
The freely programmable characteristic unit. This saves space and money, because 4...20 mA
curve, i.e., the assignment of the displayed there is no need for a second digital display.
value to the input value, is important in pro- Limit values can also be called at the
cess applications for indicating flow rates or touch of a button. Limit values 1 and 2 can bar
simply be inverted in order to display the re- With servo motors, the analog output sig- Interpolation
point 2
20 mA 30 bar
Switching behavior of relay or – In the “on” state, the relay is permanently Possible settings for the switching behavior
when it reaches a preset switching point. set to pick up when this happens. Relay picks up when SPL is exceeded
All the possible settings for the switching
Relay picks up when the value is below SPH
behavior are shown and explained in the list:
– The first two options include hysteresis, Relay picks up when SPH is exceeded
i.e., the behavior of the relay depends on Relay picks up when value is between SPL and SPH
the direction from which a switching point
is reached. Relay picks up when value is outside SPL and SPH
– For the remaining options, with the excep- Relay is permanently dropped
tion of the last two (“on” and “off”), a
Relay is permanently picked up
switching tolerance is taken into account
to prevent the relay contact from “chat- SPL = Set Point Low (lower switching point)
tering”. The relay is not switched until the SPH = Set Point High (upper switching point)
62 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Basics
Safe area
Zone 2 Sensor/
actuator MACX
Ex n Ex n
Zone 1
Sensor/
actuator MACX
Ex n Ex n
Housing
e.g., Ex d
MACX
Sensor/ Ex n
actuator
Housing
IP54*
Housing
e.g., Ex d
MINI
Sensor/ Ex n
actuator
Sensor/
actuator MINI
Ex n Ex n
Housing
IP54*
Sensor/
MINI
actuator
Ex n
Ex n
64 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Space savings of up to 65% Fault monitoring and power bridging Clearly arranged wiring
– Compared to other isolating amplifiers – The DIN rail connector simplifies supply – Eight connections, with a choice of screw
on the market with design widths up to and enables group error monitoring. or spring-cage terminal blocks.
17.5 mm.
Reduction in analog inputs on controllers Time-saving system cabling Fast and error-free signal connection
– The MINI Analog multiplexer reduces up to – Plug and play – for eight channels on the – Compact termination carriers connect
eight analog signals to a single 4 20 mA isolating amplifier and controller side. MINI Analog devices to the automation
signal. system – plug and play and hot-swappable.
GND
2 – 2
GND 1 GND 2
6 – 6 D W
+ 3
+24V +24V
7 + H
GND 3
– 4 GND 3
8 –
IN U,I U,I OUT
Configurable, up to 36 signal combinations
+24V
POWER GND 3
Zone 2
Div. 2
Ex:
Housing width 6.2 mm
Technical data
Input data U input I input
Input signal 0 ... 5 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA
– Highly compact isolating amplifier for 0 ... 10 V / 2 ... 10 V
electrical isolation, conversion, amplifica- Input resistance Approx. 100 kΩ Approx. 50 Ω
Output data U output I output
tion, and filtering of standard analog sig- Output signal 0 ... 5 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA
nals 0 ... 10 V / 2 ... 10 V
Maximum output signal Approx. 12.5 V 28 mA
– Up to 36 signal combinations can be con- No-load voltage Approx. 12.5 V
figured using DIP switches Short-circuit current Approx. 22 mA
– 3-way isolation Load RB ≥ 10 kΩ < 500 Ω (at 20 mA)
Ripple < 20 mVPP (at 10 kΩ) < 20 mVPP (at 500 Ω)
– Low power consumption General data U output I output
– Power supply possible through the foot Supply voltage UB 19.2 V DC ... 30 V DC
element (T-Connector) Nominal supply voltage 24 V DC
Current consumption < 9 mA (Voltage output, < 19 mA (Current output,
– Standard configuration: at 24 V DC incl. load) at 24 V DC incl. load)
0 ... 10 V input, 0 ... 20 mA output
Power consumption < 200 mW (Voltage output) < 450 mW (Current output)
Notes:
To order a product with an order configuration, enter the required Maximum transmission error ≤ 0.1% (of final value)
configuration by referring to the adjacent order key. Temperature coefficient < 0.01%/K, typ. < 0.002%/K
Information about power bridging, system cabling, and marking Limit frequency (3 dB) Approx. 100 Hz
components can be found starting at page 88 Step response (10 - 90%) Approx. 3.2 ms
Electrical isolation Basic insulation according to EN 61010
1) EMC: Class A product, see page 571
Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
Degree of protection IP20
Ambient temperature (operation) -20°C ... 65°C
Mounting Any
Housing material PBT
Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR 3-way isolating amplifier, for electrical isolation of
analog signals,
Order configuration Screw connection MINI MCR-SL-UI-UI1) 2864383 1
Order configuration Spring-cage conn. MINI MCR-SL-UI-UI-SP1) 2864710 1
Standard configuration Screw connection MINI MCR-SL-UI-UI-NC1) 2864150 1
Standard configuration Spring-cage conn. MINI MCR-SL-UI-UI-SP-NC1) 2864163 1
66 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Order key MINI MCR-SL-UI-UI (Standard configuration entered as example)
Level sensor
24V
0...20mA 0...10V
1 IN OUT 5
2 GND1 GND2 6
Control system
3 UB+ UB+ 7
4 GND3 GND3 8
Mains voltage
GND
2 – 2
GND 1 GND 2
6 – 6 D W
+ 3
+24V +24V
7 + H
GND 3
– 4 GND 3
8 –
IN U U,I OUT
Configurable, for shunt measurements
+24V
POWER GND 3
Zone 2
Ex:
Housing width 6.2 mm
Technical data
Input data
Input signal (can be configured using DIP switches) 0 ... 50 mV
– Highly compact isolating amplifier for Maximum input signal Approx. 30 V DC
electrical isolation, conversion, amplifica- Input resistance Approx. 10 kΩ
Output data U output I output
tion, and filtering of mV signals to create Output signal (configurable using the DIP switch) 0 ... 5 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA
standard analog signals 0 ... 10 V / 2 ... 10 V
-5 ... 5 V / -10 ... 10 V
– Ideal for converting signals in the case of ( The bi-polar output can be used
shunt measurements only for bi-polar input signals.)
– Up to 280 signal combinations can be
configured using DIP switches
Maximum output signal 12.5 V 28 mA
– 3-way isolation Load RB ≥ 10 kΩ < 500 Ω (at 20 mA)
– Low power consumption Ripple < 20 mVPP (at 10 kΩ) < 20 mVPP (at 500 Ω)
– Power supply possible through the foot General data
Supply voltage UB 19.2 V DC ... 30 V DC
element (T-Connector) Nominal supply voltage 24 V DC
– Standard configuration: Power consumption < 450 mW (Current output)
Maximum transmission error ≤ 0.2%
0 ... 50 mV input, 0 ... 20 mA output Temperature coefficient < 0.01%/K, typ. < 0.002%/K
Limit frequency (3 dB) (100 Hz / 30 Hz switchable)
Notes:
Step response (10 - 90%) 3.5 ms (At 100 Hz)
To order a product with an order configuration, enter the required Electrical isolation Basic insulation according to EN 61010
configuration by referring to the adjacent order key. Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
Information about power bridging, system cabling, and marking Degree of protection IP20
components can be found starting at page 88 Ambient temperature (operation) -20°C ... 65°C
1) EMC: Class A product, see page 571 Mounting Any
Housing material PBT
Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR 3-way isolating amplifier, for realization of mV voltages in
standard signals,
Order configuration Screw connection MINI MCR-SL-SHUNT-UI 2810858 1
Order configuration Spring-cage conn. MINI MCR-SL-SHUNT-UI-SP 2810874 1
Standard configuration Screw connection MINI MCR-SL-SHUNT-UI-NC1) 2810780 1
Standard configuration Spring-cage conn. MINI MCR-SL-SHUNT-UI-SP-NC1) 2810793 1
68 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Order key MINI MCR-SL-SHUNT-UI-... (standard configuration entered as an example)
Note:
A bipolar output (-5...+5 V, -10...+10 V) can only be used for a bipolar input signal.
Shunt 1 IN OUT 5
resistor ±...mV U/I
2 GND1 GND2 6
Controller
3 UB+ UB+ 7
4 GND3 GND3 8
MINI MCR-SL-SHUNT-UI 24V
+ –
Battery
Supply
GND
2 – 2
GND 1 GND 2
6 – 6 D W
+ 3
+24V +24V
7 + H
GND 3
– 4 GND 3
8 –
IN U U,I OUT
Configurable,
+24V
POWER GND 3 for 0 ... 24 V / 0 ... 30 V input signals
Zone 2
Div. 2
Ex:
Housing width 6.2 mm
Technical data
Input data
Input signal 0 ... 24 V / 0 ... 30 V
– Highly compact isolating amplifier for Input resistance Approx. 125 kΩ (0 ... 24 V)
electrical isolation, conversion, amplifica- Output data U output I output
Output signal (configurable using the DIP switch) 0 ... 5 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA
tion, and filtering of 24 V or 30 V DC 0 ... 10 V / 2 ... 10 V
signals to create standard analog signals Maximum output signal ≤ 12.5 V 28 mA
No-load voltage ≤ 12.5 V
– Up to 12 signal combinations can be con- Short-circuit current ≤ 22 mA
figured using DIP switches Load RB > 10 kΩ < 500 Ω (at 20 mA)
– 3-way isolation Ripple < 20 mVPP (at 10 kΩ) < 20 mVPP (at 500 Ω)
General data
– Low power consumption Supply voltage UB 19.2 V DC ... 30 V DC
– Power supply possible through the foot Power consumption < 450 mW
element (T-Connector) Maximum transmission error < 0.1% (of final value)
Temperature coefficient < 0.01%/K, typ. < 0.002%/K
– Standard configuration: Limit frequency (3 dB) Approx. 100 Hz
0 ... 30 V input, 0 ... 20 mA output Step response (10 - 90%) Approx. 3.5 ms
Electrical isolation Basic insulation according to EN 61010
Notes: Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
To order a product with an order configuration, please enter the Ambient temperature (operation) -20°C ... 65°C
desired configuration by referring to the order key; see below. Housing material PBT
Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Information about power bridging, system cabling, and marking
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
components can be found starting at page 88
Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
1) EMC: Class A product, see page 571 Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR 3-way isolating amplifier, for electrical isolation of
analog signals,
Order configuration Screw connection MINI MCR-SL-U-UI1) 2864053 1
Order configuration Spring-cage conn. MINI MCR-SL-U-UI-SP1) 2811213 1
Standard configuration Screw connection MINI MCR-SL-U-UI-NC1) 2865007 1
Standard configuration Spring-cage conn. MINI MCR-SL-U-UI-SP-NC1) 2810078 1
Mains voltage
Signal conversion to uninterruptible power supply (UPS)
70 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Analog IN / Analog OUT
3-way isolating amplifier
OUT U IN U OUT I
1 + 1 5 + 5
US 4-wire active passive
GND
2 – 2
GND 1 GND 2
6 – 6 D W
+ 3
+24V +24V
7 + H
GND 3
– 4 GND 3
8 –
IN U,I U,I OUT
With fixed signal combinations
+24V
POWER GND 3
Zone 2
Ex:
Technical data
Input data U input I input
Input resistance Approx. 100 kΩ Approx. 50 Ω
– Highly compact isolating amplifier for elec- Output data U output I output
trical isolation, conversion, amplification, Maximum output signal 12.5 V 28 mA
No-load voltage Approx. 12.5 V
and filtering of standard analog signals Short-circuit current Approx. 2 mA
– Fixed signal combinations Load RB ≥ 10 kΩ ≤ 500 Ω
Ripple < 20 mVPP (at 10 kΩ) < 20 mVPP (at 500 Ω)
– Entry-level alternative to configurable General data
isolating amplifiers Supply voltage UB 19.2 V DC ... 30 V DC
– 3-way isolation Nominal supply voltage 24 V DC
Current consumption < 20 mA
– Low power consumption Maximum transmission error ≤ 0.1% (of final value)
– Power supply possible through the foot Temperature coefficient < 0.01%/K, typ. < 0.002%/K
element (T-Connector) Limit frequency (3 dB) Approx. 100 Hz
Step response (10 - 90%) Approx. 3.5 ms
Notes: Degree of protection IP20
Electrical isolation Basic insulation according to EN 61010
Information about power bridging, system cabling, and marking Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
components can be found starting at page 88
Ambient temperature (operation) -20°C ... 65°C
1) EMC: Class A product, see page 571 Housing material PBT
Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL GL EMC 2 D
Ordering data
Pcs. /
Description Input signal Output signal Type Order No.
Pkt.
MCR 3-way isolating amplifier, for electrical isolation of
analog signals,
Screw connection 0 ... 10 V 0 ... 20 mA MINI MCR-SL-U-I-01) 2813512 1
Spring-cage conn. 0 ... 10 V 0 ... 20 mA MINI MCR-SL-U-I-0-SP1) 2813570 1
GND
2 – 2
GND 3 GND 1
6 – 6 D W
OUT1 OUT 2 I +24V
H
+ 3 7 +
active
I GND 2
– 4 GND 4
8 –
IN U,I I OUT2
3 Configurable,
+24V
POWER GND 4
passive with two current output signals
4
Zone 2
Div. 2
Ex:
Housing width 6.2 mm
Technical data
Input data U input I input
Input signal 0 ... 10 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA
– Highly compact isolating amplifier for Maximum input signal 30 V 50 mA
electrical isolation, conversion, amplifica- Input resistance Approx. 100 kΩ Approx. 50 Ω
Output data
tion, filtering, and duplication of standard Output signal (configurable using the DIP switch) 2x ; 0 ... 20 mA / 4 ... 20 mA
analog signals Maximum output signal 22 mA
No-load voltage 9V
– Duplication of a standard analog signal on Load RB ≤ 250 Ω (at 20 mA)
two current outputs Ripple < 20 mVPP (at 250 Ω)
– Up to 8 signal combinations can be config- General data
Supply voltage UB 19.2 V DC ... 30 V DC
ured using DIP switches Current consumption < 30 mA (at 24 V DC incl. load)
– 4-way isolation Power consumption < 600 mW
– Power supply possible through the foot Maximum transmission error ≤ 0.2% (of final value), typ. < 0.1%
Temperature coefficient < 0.01%/K, typ. < 0.004%/K
element (T-Connector) Limit frequency (3 dB) Approx. 35 Hz
– Standard configuration: Step response (0 - 99%) Approx. 10 ms
Electrical isolation Basic insulation according to EN 61010
Input: 0 ... 10 V, output 1: 0 ... 20 mA, Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
output 2: 0 ... 20 mA Ambient temperature (operation) -20°C ... 60°C
Housing material PBT
Notes: Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
To order a product with an order configuration, please enter the Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
desired configuration by referring to the order key; see below. Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Conformance / approvals
Information about power bridging, system cabling, and marking
components can be found starting at page 88 Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
1) EMC: Class A product, see page 571 UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR signal duplicator, for duplication and electrical isolation of
analog signals
Order configuration Screw connection MINI MCR-SL-UI-2I1) 2864794 1
Order configuration Spring-cage conn. MINI MCR-SL-UI-2I-SP1) 2864804 1
Standard configuration Screw connection MINI MCR-SL-UI-2I-NC1) 2864176 1
Standard configuration Spring-cage conn. MINI MCR-SL-UI-2I-SP-NC1) 2864189 1
Input Output combi- Behavior of the analog out- Factory calibration certifi-
Order No. nation 1) puts cate (FCC) Explanation for output combination:
2864794 / IN03 / A / 0 / NONE Output 1 Output 2
NONE = without FCC A 0...20 mA 0...20 mA
2864794 = IN01 = 0...20 mA A 0 = Analog behavior YES = with FCC (a fee B 0...20 mA 4...20 mA
...-UI-2I IN02 = 4...20 mA B is charged) C 4...20 mA 4...20 mA
IN03 = 0...10 V C 1 = Limitation
2864804 = IN06 = 1...5 V YESPLUS = FCC with
...-UI-2I-SP 5 measuring
points (a fee is
charged)
1) For explanations, see adjacent text on the right; for further details, see data sheet: www.phoenixcontact.net/products
72 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Analog IN / Analog OUT
repeater power supplies
OUT I IN I OUT I
1 – 1 5 + 5
Zone 2
Ex:
Housing width 6.2 mm
Technical data
Input data MINI MCR-SL-RPSS-I-I1) MINI MCR-SL-RPS-I-I1)
Input signal 0 ... 20 mA, 0 ... 20 mA,
– Highly compact repeater power supplies isolator operation / 4 ... 20 mA isolator operation / 4 ... 20 mA
for electrical isolation, amplification, and Input resistance Approx. 50 Ω Approx. 50 Ω
filtering of standard analog signals Transmitter supply voltage 16.5 V 14.7 V DC ... 25.5 V DC
(UB - max. 4.5 V for load
– Supply of 2-conductor and passive 3-con- 0 mA ... 20 mA)
ductor sensors Output data
– Can also be used as an isolator without Output signal 0 ... 20 mA / 4 ... 20 mA 0 ... 20 mA / 4 ... 20 mA
Maximum output signal 21 mA 28 mA
supply No-load voltage Approx. 12.5 V Approx. 12.5 V
– 3-way isolation Load RB ≤ 500 Ω (at I = 20 mA) ≤ 500 Ω (at I = 20 mA)
Ripple < 20 mVrms (at 500 Ω) < 20 mVrms (at 500 Ω)
– Alternatively bidirectional HART trans- General data
mission Supply voltage UB 20.4 V DC ... 30 V DC 19.2 V DC ... 30 V DC
– Power supply possible through the foot Nominal supply voltage 24 V DC 24 V DC
Current consumption
element (T-Connector) Power consumption < 900 mW (at 24 V DC and in < 900 mW (at 24 V DC and in
repeater power supply operation) repeater power supply operation)
Notes:
Information about power bridging, system cabling, and marking Maximum transmission error ≤ 0.2% (of final value), ≤ 0.2% (of final value),
components can be found starting at page 73 typ. ≤ 0.1% (of final value) typ. ≤ 0.1% (of final value)
1) EMC: Class A product, see page 571
Temperature coefficient < 0.005%/K, typ. < 0.002%/K < 0.01%/K, typ. < 0.002%/K
Limit frequency (3 dB) 175 Hz (typ.) Approx. 100 Hz
Communication HART specification in both -
operating modes (RPSS isolator /
RPSS repeater power supply)
Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Conformance / approvals
Conformance CE-compliant CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized applied for UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D Class I, Div. 2, Groups A, B, C, D
T5 applied for T5
GL GL EMC 2 D GL EMC 2 D
Ordering data
Pcs. /
4...20mA Description Type Order No.
1 IN I OUT I 5 Pkt.
Mains voltage
OUT I IN I 1 OUT I 1
1 + 1 5 + 5
US PWR active passive
4-wire
max.18 VDC
GND
2 – 2
GND 1 GND 2
6 – 6 D W
OUT I
3 + 3
IN I 2 OUT I 2
7 + 7 H
PWR
US 4-wire max.18 VDC active passive
GND 3
4 – 4 GND 4
GND 8– 8
IN I I OUT
Either 1- or 2-channel
Zone 2
Ex:
Housing width 6.2 mm
Technical data
Input data
Input signal 0 ... 20 mA / 4 ... 20 mA
– Highly compact 2-conductor passive iso- Voltage drop 1.7 V (at I = 20 mA)
lators for electrical isolation and filtering Response current Approx. 190 µA
Maximum input current / overload 40 mA
of standard analog signals Maximum input voltage 18 V
– Input loop-supplied Output data
Output signal 0 ... 20 mA / 4 ... 20 mA
– Does not require any additional auxiliary Load RB < 600 Ω (at I = 20 mA output signal)
voltage Ripple < 10 mVrms (at 600 Ω)
– 2 channels in conj. with a design width of General data
Maximum transmission error ≤ 0.1% (of final value)
just 6.2 mm Additional error per 100 Ω load 0.03% (of measured value / 100 Ω load)
– Voltage drop on isolating amplifier of Temperature coefficient ≤ 0.002%/K (of measured value / 100 Ω load)
just 1.7 V Limit frequency (3 dB) 75 Hz
Step response (10 - 90%) 5 ms (At 600 Ω load)
Notes: Electrical isolation Basic insulation according to EN 61010
Test voltage input/output 1.5 kV (50 Hz, 1 min.)
When using passive isolators, make sure that the current sourcing Degree of protection IP20
voltage of the measuring transducer UB is sufficient to drive the
maximum current of 20 mA via the passive isolator with a voltage Ambient temperature (operation) -20°C ... 65°C
drop UV = 1.7 V and load RB. Mounting Any
This means: Housing material PBT
UB ≥ UE = 1.7 V + 20 mA x RB Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Information on components for power bridging, system cabling, Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
and marking can be found in the INTERFACE catalog or at Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
www.phoenixcontact.net/products Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA II T6 X
UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR passive isolator, for electrical isolation of current signals
without auxiliary power
two-channel Screw connection MINI MCR-SL-2CP-I-I 2864655 1
two-channel Spring-cage conn. MINI MCR-SL-2CP-I-I-SP 2864781 1
single-channel Screw connection MINI MCR-SL-1CP-I-I 2864419 1
single-channel Spring-cage conn. MINI MCR-SL-1CP-I-I-SP 2864749 1
UB
UV = 1,7 V
I
I
UE RB
I I
MINI MCR-SL-1CP-I-I
74 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Analog IN/Analog OUT
loop-powered isolator
OUT IN I PWR IN
1 + 1 5 + 5
I
US passive PWR
4-wire
active
GND
2 – 2
GND OUT I
6 – 6 D W
OUT
U
3 + 3
IN U
7 H
US 4-wire
U, I GND
4 – 4
GND 8
IN POWER
OUT Configurable,
I up to 74 signal combinations,
loop-powered
Zone 2
Applied for:
cUL / UL
Housing width 6.2 mm
Technical data
Input data U input I input
Input signal (configurable using the DIP switch) 2 ... 10 V, additional areas can be configured, see table
– Highly compact isolating amplifier for
electrical isolation, conversion, and filter- Maximum input signal < 40 V < 50 mA
ing of standard analog signals (Dielectric strength up to 30 V)
– Supplied by an output loop Input resistance Approx. 100 kΩ (At ≤ 1 V,
otherwise approximately 1 MΩ)
≤ 50 Ω
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR loop-powered isolator
Screw connection MINI MCR-SL-UI-I-LP-NC1) 2902829 1
Spring-cage conn. MINI MCR-SL-UI-I-LP-SP-NC1) 2902830 1
S-Port
OUT U,I
1 1 5 + 5
active
GND 1
passive
D W
2 2 6 – 6
ϑ ϑ ϑ
3 3
+24V
7 +
H
4 4 GND 2
IN U,I OUT 8 –
FM
GND 2 +24V Universal measuring transducer
FM
POWER for resistance thermometers
Zone 2
Accessories
Programming adapter for configuring modules with IFS-USB-PROG-ADAPTER1) 2811271 1
S-PORT interface
PT 100
OUT U,I
1 1 5 + 5
active passive
2 2
GND 1
6 – 6 D W
ϑ ϑ ϑ
3 3
+24V
7 + H
4 4 GND 2
8 –
IN U,I OUT
PT100
Configurable, for a temperature measuring
+24V
POWER GND 2 range of -50°C ... +200°C
Zone 2
Div. 2
Ex:
Housing width 6.2 mm
Technical data
Input data
Input signal (can be configured using DIP switches) Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-conductor
– Highly compact temperature transducer Temperature range -50°C ... 200°C (configurable)
for electrical isolation, conversion, ampli- Measuring range span min. 50 K
Output data U output I output
fication, and filtering of Pt 100 signals to Output signal 0 ... 5 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA
create standard signals 0 ... 10 V / 10 ... 0 V 20 ... 0 mA / 20 ... 4 mA
Maximum output signal Approx. 12.5 V 23 mA
– Optimized temperature measuring range Load RB > 10 kΩ < 500 Ω (at 20 mA)
of -50°C to +200°C for increased accuracy Ripple < 20 mVPP (at 10 kΩ) < 20 mVPP (at 500 Ω)
– For 2-, 3- or 4-conductor Pt 100 sensors General data
Supply voltage UB 19.2 V DC ... 30 V DC
according to IEC 60751 Current consumption < 21 mA (at 24 V DC)
– Input and output signals can be configured Power consumption < 500 mW
via DIP switches Transmission error for the full/set measurement range ≤ 0.25% ; ((50 K / Δ Temp) + 0.05)%
Temperature coefficient < 0.02%/K
– 3-way isolation Step response (0 - 99%) < 200 ms
– Error signaling via diagnostic LED and an- Electrical isolation Basic insulation according to EN 61010
Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
alog signal Ambient temperature (operation) -20°C ... 65°C
– Power supply possible through the foot Housing material PBT
element (T-Connector) Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
Notes: Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Conformance / approvals
To order a product with an order configuration, please enter the
desired configuration by referring to the order key; see below. Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
Information about power bridging, system cabling, and marking UL, USA / Canada UL 508 Recognized
components can be found starting at page 88 Class I, Div. 2, Groups A, B, C, D T5
1) EMC: Class A product, see page 571 GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducer, for
Pt 100 temperature sensors
Order configuration Screw connection MINI MCR-SL-PT100-UI-200 2864309 1
Order configuration Spring-cage conn. MINI MCR-SL-PT100-UI-200-SP1) 2864192 1
Unconfigured Screw connection MINI MCR-SL-PT100-UI-200-NC1) 2864370 1
Unconfigured Spring-cage conn. MINI MCR-SL-PT100-UI-200-SP-NC1) 2864202 1
Connection Measuring range [°C] Output Failure in- Factory calibration Failure information (depends on the output signal range):
Order No. technology Start End formation 1) certificate (FCC) Overrange Open circuit
2864309 / 3 / 0 / 100 / OUT01 / A / NONE 0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 0...10 V
2 = 2-con- 0 Range OUT01 = 0...20 mA A NONE = without FCC A 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V
2864309 = ductor -5 (increment) OUT02 = 4...20 mA B YES = with FCC (a fee B 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V
...-PT100-UI-200 3 = 3-con- -10 OUT03 = 0...10 V C is charged) C 20 mA 20 mA 10 V 21 mA 21 mA 10.5 V
D 20 mA 20 mA 10 V 0 mA 4 mA 0V
ductor -15 0...200 (5 K) OUT05 = 0...5 V D
2864192 = 4 = 4-con- -20 OUT06 = 1...5 V YESPLUS = FCC with Underrange Short circuit
...-PT100-UI-200-SP ductor -30 OUT07 = 20...0 mA 5 measuring 0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 0...10 V
-40 OUT08 = 20...4 mA points (a fee is A 0 mA 4 mA 0V 0 mA 4 mA 0V
-50 OUT09 = 10...0 V charged) B 0 mA 3.5 mA 0V 0 mA 3 mA 0V
C 0 mA 4 mA 0V 21 mA 21 mA 10.5 V
1) For explanations, see adjacent text on the right; for further details, see data sheet: www.phoenixcontact.net/products D 0 mA 4 mA 0V 0 mA 4 mA 0V
PT 100
OUT U,I
1 1 5 + 5
active passive
2 2
GND 1
6 – 6 D W
ϑ ϑ ϑ
3 3
+24V
7 + H
4 4 GND 2
8 –
IN U,I OUT
PT100
Configurable, for a temperature measuring
+24V
POWER GND 2 range of -150°C ... +850°C
Zone 2
Div. 2
Ex:
Housing width 6.2 mm
Technical data
Input data
Input signal (can be configured using DIP switches) Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-conductor
– Highly compact temperature transducer Temperature range -150°C ... 850°C (configurable)
for electrical isolation, conversion, ampli- Measuring range span min. 50 K
Output data U output I output
fication, and filtering of Pt 100 signals to Output signal (configurable using the DIP switch) 0 ... 5 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA
create standard signals 0 ... 10 V / 10 ... 0 V 20 ... 0 mA / 20 ... 4 mA
Maximum output signal Approx. 12.5 V 23 mA
– Temperature measuring range of Load RB ≥ 10 kΩ < 500 Ω (at 20 mA)
-150°C to +850°C Ripple < 20 mVPP (at 10 kΩ) < 20 mVPP (at 500 Ω)
– For 2-, 3- or 4-conductor Pt 100 sensors General data
Supply voltage UB 19.2 V DC ... 30 V DC
according to IEC 60751 Current consumption < 21 mA (at 24 V DC)
– Input and output signals can be configured Power consumption < 500 mW
via DIP switches Transmission error for the full/set measurement range ≤ 0.2% ; ((100 K / set measurement range [K]) + 0.1%)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducer, for
Pt 100 temperature sensors
Order configuration Screw connection MINI MCR-SL-PT100-UI1) 2864435 1
Order configuration Spring-cage conn. MINI MCR-SL-PT100-UI-SP 2864736 1
Unconfigured Screw connection MINI MCR-SL-PT100-UI-NC1) 2864273 1
Unconfigured Spring-cage conn. MINI MCR-SL-PT100-UI-SP-NC1) 2864286 1
Connection Measuring range [°C] Output Failure in- Factory calibration certifi- Failure information (depends on the output signal range):
Order No. technology Start End formation 1) cate (FCC) Overrange Open circuit
2864435 / 3 / 0 / 100 / OUT01 / A / NONE 0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 0...10 V
2 = 2-conduc- 0 Range OUT01 = 0...20 mA A NONE = without FCC A 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V
2864435 = tor -10 (increment) OUT02 = 4...20 mA B YES = with FCC (a fee B 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V
...-PT100-UI 3 = 3-conduc- -20 OUT03 = 0...10 V C is charged) C 20 mA 20 mA 10 V 21 mA 21 mA 10.5 V
D 20 mA 20 mA 10 V 0 mA 4 mA 0V
tor -30 0...100 (5 K) OUT05 = 0...5 V D
2864736 = 4 = 4-conduc- -40 110...300 (10 K) OUT06 = 1...5 V YESPLUS = FCC with Underrange Short circuit
...-PT100-UI-SP tor -50 320...700 (20 K) OUT07 = 20...0 mA 5 measuring 0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 0...10 V
-100 750...850 (50 K) OUT08 = 20...4 mA points (a fee is A 0 mA 4 mA 0V 0 mA 4 mA 0V
-150 OUT09 = 10...0 V charged) B 0 mA 3.5 mA 0V 0 mA 3 mA 0V
C 0 mA 4 mA 0V 21 mA 21 mA 10.5 V
1) For explanations, see adjacent text on the right; for further details, see data sheet: D 0 mA 4 mA 0V 0 mA 4 mA 0V
www.phoenixcontact.net/products
78 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Temperature
Temperature transducer for Pt 100
PT 100
PWR IN
1 1 5 + 5
passive PWR
active
2 2
OUT I
6 – 6 D W
ϑ ϑ ϑ
3 3 7 H
4 4
8
IN POWER
I
PT100 OUT Configurable, for a temperature measuring
range of -150°C ... +300°C, loop-powered
Zone 2
Ex:
Housing width 6.2 mm
Technical data
Input data
Input signal (can be configured using DIP switches) Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-conductor
– Highly compact loop-powered tempera- Temperature range -150°C ... 300°C (configurable)
ture transducer for electrical isolation, Measuring range span min. 50 K
Output data
conversion, amplification, and filtering of Output signal 4 ... 20 mA / 20 ... 4 mA
Pt 100 signals to create standard signals Maximum output signal 23 mA
Load RB ((Usupply - 12 V) / 22 mA)
– Supplied by an output loop Ripple < 20 mVPP (at 500 Ω)
– Does not require any additional auxiliary General data
voltage Supply voltage UB 12 V DC ... 30 V DC
Current consumption < 3.5 mA (without signal current)
– Temperature measuring range of Power consumption < 42 mW (without signal current)
-150°C to +300°C Transmission error for the full/set measurement range ≤ 0.25% ; ((90 K / set measuring range [K]) + 0.05%)
– 2-, 3- or 4-conductor Pt 100 sensors Temperature coefficient < 0.02%/K
– Input signals can be configured via DIP Step response (0 - 99%) < 200 ms
switches Electrical isolation Basic insulation according to EN 61010
Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
– 2-way isolation Degree of protection IP20
– Error signaling via diagnostic LED and Ambient temperature (operation) -20°C ... 65°C
analog signal Mounting Any
Housing material PBT
Notes: Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
To order a product with an order configuration, please enter the Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
desired configuration by referring to the order key; see below.
Conformance / approvals
Information about power bridging, system cabling, and marking Conformance CE-compliant
components can be found starting at page 88 ATEX II 3 G Ex nA IIC T4 Gc X
1) EMC: Class A product, see page 571 UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducer, for
Pt 100 temperature sensors, loop-powered
Order configuration Screw connection MINI MCR-SL-PT100-LP 2810298 1
Order configuration Spring-cage conn. MINI MCR-SL-PT100-LP-SP 2810382 1
Unconfigured Screw connection MINI MCR-SL-PT100-LP-NC1) 2810308 1
Unconfigured Spring-cage conn. MINI MCR-SL-PT100-LP-NC-SP1) 2810395 1
Connection Measuring range [°C] Output Failure in- Factory calibration certifi- Failure information
Order No. technology Start End formation 1) cate (FCC) Overrange Open circuit
2810298 / 3 / 0 / 100 / OUT02 / 1 / NONE
2 = 2-conductor 0 Range NONE = without FCC 1 - Start of range
2810298 = -10 (increment) OUT02 = 4...20 mA 1 YES = with FCC (a fee 2 21.5 mA 21.5 mA
3 3.5 mA 3.5 mA
...-PT100-LP 3 = 3-conductor -20 OUT08 = 20...4 mA 2 is charged)
4 21.5 mA 21.5 mA
-30 0...300 (5 K) 3
2810382 = 4 = 4-conductor -40 4 YESPLUS = FCC with Underrange Short circuit
...-PT100-LP-SP -50 5 measuring
-100 points (a fee is 1 - Start of range
-150 charged) 2 21.5 mA 21.5 mA
3 3.5 mA 3.5 mA
1) For explanations, see adjacent text on the right; for further details, see data sheet: www.phoenixcontact.net/products 4 3.5 mA 3.5 mA
S-Port
OUT U,I
1 + 1 5 + 5
active
TC
GND 1
passive
D W
2 – 2 6 – 6
3
+24V
7 +
H
4 GND 2
IN U,I OUT 8 –
FM
GND 2 +24V Universal measuring transducer
FM
POWER for thermocouples
Zone 2
IEC 584 TC; cold junction compensation Cold junction errors < 3 K ( typ. < 2 K )
“ON”; -200 ... 1200°C; 4 ... 20 mA out- Temperature coefficient ≤ 0.01%/K
Step response (0 - 99%) Typ. 400 ms
put; error evaluation according to NE43 Electrical isolation Basic insulation according to EN 61010
(downscale); fault monitoring contact re- Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
sponds on any error. Ambient temperature (operation) -20°C ... 65°C
Housing material PBT
Notes: Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
For information on the programming adapter, refer to page 119
Conformance / approvals
The configuration software can be downloaded from the Internet: Conformance CE-compliant
www.phoenixcontact.net/products ATEX II 3 G Ex nA IIC T4 Gc X
Information about power bridging, system cabling, and marking UL, USA / Canada UL 508 Recognized applied for
components can be found starting at page 88 Class I, Div. 2, Groups A, B, C, D T5 applied for
GL GL applied for
1) EMC: Class A product, see page 571
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Universal temperature transducer for thermocouples
Accessories
Programming adapter for configuring modules with IFS-USB-PROG-ADAPTER1) 2811271 1
S-PORT interface
Sensor type Standard Measuring range Sensor type Standard Measuring range
B IEC 584-1 +500°C ... +1820°C L DIN 43710 -200°C ... +900°C
E IEC 584-1 -230°C ... +1000°C U DIN 43710 -200°C ... +600°C
J IEC 584-1 -210°C ... +1200°C A-1 GOST 8.585 0°C ... +2500°C
K IEC 584-1 -250°C ... +1372°C A-2 GOST 8.585 0°C ... +1800°C
N IEC 584-1 -200°C ... +1300°C A-3 GOST 8.585 0°C ... +1800°C
R IEC 584-1 -50°C ... +1768°C M GOST 8.585 -200°C ... +100°C
S IEC 584-1 -50°C ... +1768°C L GOST 8.585 -200°C ... +800°C
T IEC 584-1 -200°C ... +400°C Customer-specific characteristic curves
80 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Temperature
Temperature transducer for
J- and K-type thermocouples
OUT U,I
1 1 5 + 5
active passive
TC
2 + 2
GND 1
6 – 6 D W
3
– 3
+24V
7 + H
4 GND 2
8 –
IN U,I OUT
Configurable, for a temperature measuring
+24V
POWER GND 2 range of -150°C ... +1350°C
Zone 2
Div. 2
Ex:
Housing width 6.2 mm
Technical data
Input data
Input signal (can be configured using DIP switches) Thermocouples type J, K (IEC 584-1)
– Highly compact temperature transducer
Temperature range Typ J : -150°C ... 1200°C (configurable)
for electrical isolation, conversion, ampli- Typ K : -150°C ... 1350°C
fication, and filtering of thermocouple sig- Measuring range span min. 50 K
nals to create standard signals Output data U output I output
Output signal (configurable using the DIP switch) 0 ... 5 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA
– Temperature measuring range of 0 ... 10 V / 10 ... 0 V 20 ... 0 mA / 20 ... 4 mA
-150°C to +1350°C Maximum output signal Approx. 12.5 V 23 mA
– For J and K thermocouples according to No-load voltage Approx. 12.5 V
Short-circuit current Approx. 10 mA
IEC 584-1 Load RB ≥ 10 kΩ < 500 Ω (at 20 mA)
– Internal cold junction compensation Ripple < 20 mVPP (at 10 kΩ) < 20 mVPP (at 500 Ω)
General data
– Input and output signals can be configured Supply voltage UB 19.2 V DC ... 30 V DC
via DIP switches Current consumption < 25 mA (at 24 V DC)
– 3-way isolation Power consumption < 500 mW
Transmission error for the full/set measurement range ≤ 0.2% ; ((150 K / set measurement range [K]) + 0.1%)
– Error signaling via diagnostic LED and
analog signal Cold junction errors < 3 K ( typ. < 2 K )
Temperature coefficient < 0.02%/K
– Power supply possible through the foot Step response (0 - 99%) < 30 ms
element (T-Connector) Electrical isolation Basic insulation according to EN 61010
Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
Notes: Ambient temperature (operation) -20°C ... 65°C
To order a product with an order configuration, please enter the Housing material PBT
desired configuration by referring to the order key; see below. Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Information about power bridging, system cabling, and marking Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
components can be found starting at page 88 Conformance / approvals
Conformance CE-compliant
1) EMC: Class A product, see page 571
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducer, for thermocouples
Sensor type Measuring range [°C] Output Failure in- Factory calibration certifi- Failure information (depends on the output signal range):
Order No. Start End formation 1) cate (FCC) Overrange Open circuit
2864448 / J / 0 / 1000 / OUT01 / A / NONE 0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA 0...10 V
J = Type J 0 Range OUT01 = 0...20 mA A NONE = without FCC A 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V
-10 (increment) OUT02 = 4...20 mA B YES = with FCC (a fee B 20.5 mA 20.5 mA 10.25 V 21 mA 21 mA 10.5 V
K = Type K -20 OUT03 = 0...10 V C is charged) C 20 mA 20 mA 10 V 21 mA 21 mA 10.5 V
D 20 mA 20 mA 10 V 0 mA 4 mA 0V
-30 OUT05 = 0...5 V D
-40 0 ... 300 (10 K) OUT06 = 1...5 V YESPLUS = FCC with Underrange
-50 320 ... 700 (20 K) OUT07 = 20...0 mA 5 measuring 0...20 mA 4...20 mA 0...10 V
-100 750...1350 (50 K) OUT08 = 20...4 mA points (a fee is A 0 mA 4 mA 0V
-150 OUT09 = 10...0 V charged) B 0 mA 3.5 mA 0V
C 0 mA 4 mA 0V
1) For explanations, see adjacent text on the right; for further details, see data sheet: www.phoenixcontact.net/products D 0 mA 4 mA 0V
2 3
PNP +24V
7 +
H
NPN
PNP
4 GND 1
4 GND 3
IN U,I OUT 8 –
FM
3 GND 2 +24V Frequency transducer for up to 80 kHz
FM
POWER 4
Zone 2
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR frequency transducers
Standard configuration Screw connection MINI MCR-SL-F-UI-NC1) 2902832 1
Standard configuration Spring-cage conn. MINI MCR-SL-F-UI-SP-NC1) 2902833 1
82 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Frequency
Analog-frequency transducer
GND – OUT +
GND 1 GND 2
2 – 2 6 – 6
GND
+24V +24V
H
+ 3 7 + RL
GND 3
IN U,I f OUT – 4 GND 3
8 –
Configurable,
POWER +24V
frequency and PWM output
GND 3
Zone 2
Ex:
Housing width 6.2 mm
Technical data
Input data U input I input
Input signal (configurable using the DIP switch) 0 ... 5 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA
– Highly compact analog-to-frequency 0 ... 10 V / 2 ... 10 V 0 ... 10 mA / 2 ... 10 mA -
transducer for electrical isolation, amplifi- Maximum input signal 30 V DC 100 mA
Input resistance Approx. 110 kΩ Approx. 50 Ω
cation, conversion, and filtering of stan- Output data Frequency output PWM output
dard signals to create frequencies or Output signal (can be configured using DIP switches) 0 Hz ... 10 kHz / 0 Hz ... 5 kHz 7.8 kHz (10 bit) / 3.9 kHz (10 bit)
0 Hz ... 2.5 kHz / 0 Hz ... 1 kHz 1.9 kHz (12 bit) / 977 Hz (12 bit)
PWM signals 0 Hz ... 500 Hz / 0 Hz ... 250 Hz 488 Hz (14 bit) / 244 Hz (14 bit)
– Configurable interference filter 0 Hz ... 100 Hz / 0 Hz ... 50 Hz 122 Hz (16 bit) / 61 Hz (16 bit)
– Input and output signals can be configured Minimum load 4 mA ≤ (UL / RL) ≤ 20 mA 12 mA ≤ (UL / RL) ≤ 20 mA
Maximum load current 20 mA
via DIP switches Maximum switching voltage 30 V
– 3-way isolation Overrange/underrange Can be set (via DIP switch)
– Error signaling via diagnostic LED and Protective circuit Short-circuit protection, polarity reversal protection
General data
analog signal Supply voltage UB 19.2 V DC ... 30 V DC
– Power supply possible through the foot Nominal supply voltage 24 V DC
Current consumption < 10 mA (at 24 V DC)
element (T-Connector) Power consumption < 200 mW
– PWM output of 5 ... 95% Maximum transmission error ≤ 0.1% (> 7 kHz ≤ 0.2%)
Temperature coefficient < 0.02%/K
Notes: Step response (0 - 99%) < 15 ms (+ (1/f) smallest filter)
Information about power bridging, system cabling, and marking < 1 s (+ (1/f) largest filter)
components can be found starting at page 88 Electrical isolation Basic insulation according to EN 61010
Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
1) EMC: Class A product, see page 571
Degree of protection IP20
Ambient temperature (operation) -20°C ... 65°C
Mounting Any
Housing material PBT
Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR frequency transducer
Screw connection MINI MCR-SL-UI-F1) 2864082 1
Frequency output Spring-cage conn. MINI MCR-SL-UI-F-SP1) 2810243 1
T T T T T T
IN OUT U,I
1 1 5 + 5
active passive
2 2
IN GND 1
6 – 6 D W
3 3
IN +24V
7 + H
4 GND 2
8 –
IN R U,I OUT
Configurable,
+24V
POWER GND 2 automatic potentiometer detection
Zone 2
Ex:
Housing width 6.2 mm
Technical data
Input data
Potentiometer 100 Ω ... 100 kΩ
– Highly compact potiposition transducer Reference voltage source < 3.6 V
for electrical isolation, conversion, ampli- Output data U output I output
Output signal 0 ... 5 V / 1 ... 5 V 0 ... 20 mA / 4 ... 20 mA
fication, and filtering of potentiometer 0 ... 10 V / 10 ... 0 V 20 ... 0 mA / 20 ... 4 mA
signals to create standard signals Maximum output signal 12.5 V 23 mA
No-load voltage Approx. 12.5 V
– Automatic potentiometer detection Short-circuit current Approx. 10 mA
without manual adjustment Load RB > 10 kΩ < 500 Ω (20 mA)
– For potentiometers from 100 Ω to 100 kΩ Ripple < 20 mVPP (at 10 kΩ) < 20 mVPP (at 500 Ω)
Behavior in the event of a sensor error 0% ... 105% (configurable)
– Configurable measuring range and output General data
signals Supply voltage UB 19.2 V DC ... 30 V DC
– A potentiometer sub-range can be linear- Nominal supply voltage 24 V DC
Current consumption < 25 mA (at 24 V DC)
ized via the “teach-in” switch on the de- Power consumption < 500 mW
vice Maximum transmission error < 0.2%
Temperature coefficient < 0.02%/K
– Input and output signals can be configured Step response (0 - 99%) < 30 ms
via DIP switches Electrical isolation Basic insulation according to EN 61010
– 3-way isolation Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
Degree of protection IP20
– Error signaling via diagnostic LED and an- Ambient temperature (operation) -20°C ... 65°C
alog signal Mounting Any
– Power supply possible through the foot Housing material PBT
Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
element (T-Connector) Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Notes: Conformance / approvals
Information about power bridging, system cabling, and marking Conformance CE-compliant
components can be found starting at page 88 ATEX II 3 G Ex nA IIC T4 Gc X
1) EMC: Class A product, see page 571 UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR potiposition transducer
Screw connection MINI MCR-SL-R-UI1) 2864095 1
Spring-cage conn. MINI MCR-SL-R-UI-SP1) 2810256 1
Lifting platform
M
Actuator motor ACTUAL TARGET
Potentiometer 0...10 V 0...10 V
Controller
1 OUT 5
Control system
2 GND1 6
3 UB + 7
4 GND2 8
Mains voltage
84 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Limit values
Threshold value switch
OUT IN U,I
5 + 5 1
U,I
US 4-wire
GND 1
D W
6 – 6 2 2 14
GND
+24V
H
+ 7 3 3 11
GND 2
IN U,I OUT – 8 4 4 12
Zone 2
Ex:
Housing width 6.2 mm
Technical data
Input data U input I input
Input signal (configurable using the DIP switch) 0 ... 10 V 0 ... 20 mA
– Highly compact threshold value switch for Maximum input signal 30 V 100 mA
switching analog limit values Input resistance > 100 kΩ 50 Ω
Specification of the switching point With 25-speed potentiometer
– Input signal, hysteresis, and delay time can Switching output
be configured via DIP switches Relay output 1 PDT
Contact material AgSnO2, hard gold-plated
– Limit value can be freely adjusted via po- Max. switching voltage 250 V AC
tentiometer on front Limiting continuous current 2A
– 3-way isolation Hysteresis (configurable using the DIP switch) (0.1%; 1%; 2.5%; 5%)
Operating and closed circuit current behavior Switchable using DIP switch
– PDT relay at output Setting range of the response delay (configurable using the DIP 0 s ... 10 s (0 s; 1 s; 2 s; 3 s; 4 s; 6 s; 8 s; 10 s)
– Operating current/quiescent current switch)
General data
switchover Supply voltage UB 19.2 V DC ... 30 V DC
– Status and error signaling via two diagnos- Nominal supply voltage 24 V DC
tic LEDs Current consumption < 14 mA (at 24 V DC)
Power consumption < 330 mW (at 24 V DC)
– Power supply possible through the foot Linearity error < 0.05% (of final value)
element (T-Connector) Temperature coefficient < 0.02%/K
Step response (0 - 99%) < 35 ms
Notes: Electrical isolation Basic insulation according to EN 61010
Information about power bridging, system cabling, and marking Test voltage input/power supply 1.5 kV AC (50 Hz, 1 min.)
components can be found starting at page 88 Degree of protection IP20
Ambient temperature (operation) -20°C ... 65°C
1) EMC: Class A product, see page 571
Mounting Any
Housing material PBT
Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X
UL, USA / Canada UL 508 Recognized
UL, USA Class I, Zone 2, AEx nC IIC T6
UL, Canada Class I, Zone 2, Ex nC IIC T6
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR threshold value switch
Screw connection MINI MCR-SL-UI-REL1) 2864480 1
Spring-cage conn. MINI MCR-SL-UI-REL-SP1) 2864493 1
IN OUT 1
1 + 1 5 5 13
DI 1
2 – 2
IN OUT 1
6 6 14 D W
1
3
OUT 2 +24V
7 + H
2
OUT 2
4 GND
1 8 –
IN OUT
2
3 13 Configurable, for NAMUR sensors and
+24V
POWER GND DI 2 floating contacts
4 14
Zone 2
Ex:
Housing width 6.2 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
– Highly compact isolation amplifier for Open circuit switch contacts
Switch contacts with resistance circuit
electrical isolation, amplification, and du- Control circuit
plication of proximity sensor signals No-load voltage 8.2 V DC ±10%
– For proximity sensors in accordance with Switching points (according to IEC 60947-5-6) < 1.2 mA (blocking)
> 2.1 mA (conductive)
IEC 60947-5-6 and EN 50227 Line error detection > 6 mA (in the event of a short-circuit)
– Floating contacts and contacts with resis- < 0.35 mA (With wire break)
Switching output
tance circuit can be connected Relay output 2 N/O contacts
– Input and output signals can be configured Contact material Hard gold plated AgNi
via DIP switches Maximum switching voltage 250 V AC
Maximum switching current 2A
– N/O contacts at output Minimum contact current 1 mA (for 5 V DC)
– Second output can be used as a doubler Switching frequency 0.5 Hz (240 V AC / 30 V DC / 2 A)
10 Hz (without load)
or error signaling output General data
– 3-way isolation Supply voltage UB 19.2 V DC ... 30 V DC
– Switchover between operating current Nominal supply voltage 24 V DC
Current consumption < 25 mA
and quiescent current (inverted switching Power consumption < 600 mW
behavior) Electrical isolation Basic insulation according to EN 61010
– Error signaling via diagnostic LED and an- Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
Degree of protection IP20
alog signal Ambient temperature (operation) -20°C ... 65°C
– Power supply possible through the foot Mounting Any
Housing material PBT
element (T-Connector) Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Notes: Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12
Spring-cage connection (solid/stranded/AWG) 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Information about power bridging, system cabling, and marking Conformance / approvals
components can be found starting at page 88
Conformance CE-compliant
1) EMC: Class A product, see page 571 ATEX II 3 G Ex nA nC IIC T4 Gc X
UL, USA / Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR NAMUR switching amplifier
Screw connection MINI MCR-SL-NAM-2RNO1) 2864105 1
Spring-cage conn. MINI MCR-SL-NAM-2RNO-SP1) 2810269 1
86 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Accessories
Constant voltage source
OUT OUT
OUT U OUT U
+ 1 5 +
– 2
GND 1 GND 1
6 – D W
+ 3
+24V +24V
7 + H
POWER GND 2
– 4 GND 2
8 –
IN OUT
Configurable,
UCV +24V
output signals 2.5 V / 5 V / 7.5 V / 10 V
GND 2
Ex:
Zone 2
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR constant voltage source
With screw connection Screw connection MINI MCR-SL-CVS-24-5-10-NC1) 2902822 1
With spring-cage connection Spring-cage conn. MINI MCR-SL-CVS-24-5-10-SP-NC1) 2902823 1
Accessories
Setpoint potentiometer, to set setpoints individually
group IN OUT
6
2
– For plugging gaps in system cabling with
IN OUT
the V8 system adapter, e.g., when there 3 7
D W
are fewer than eight signals IN OUT
4 8 H
– Used in conjunction with the
MINI Analog multiplexer
– For direct mounting in the case of applica-
tions without signal conversion and with- 1:1 connection
out electrical isolation
Technical data
General data
Degree of protection IP20
Ambient temperature (operation) -20°C ... 65°C
Mounting Any
Housing material PBT
Dimensions W / H / D 6.2 / 93.1 / 102.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12
Conformance / approvals
ATEX II 3 G Ex nA IIC T4 Gc X
GL GL EMC 2 D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MINI Analog feed-through terminal block
Screw connection MINI MCR-SL-TB 2811420 1
Accessories
Marking material
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Fold-up transparent cover, for labeling MINI Analog modules
with insert strips
MINI MCR DKL 2308111 10
Accessories
Insert strips, stamped, for transparent cover MINI MCR-DKL-LABEL 2810272 10
88 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Accessories
Power terminals
IN 1 2 3 4
– For up to 80 MINI Analog modules OUT FM
IN
+ 1 5 +
– The MINI MCR-SL-PTB-FM(-SP) power +24V
PWR 1 PWR 1
+24V
IN / OUT-FM IN
terminal block is used to supply the sup- – 2 6 –
Notes:
1) EMC: Class A product, see page 571 Technical data
Input data
Input voltage range 0 V DC ... 30 V DC
Output data
Output voltage (Input voltage - 0.8 V)
Output current ≤2A
General data
Ambient temperature (operation) -20°C ... 65°C
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized applied for
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL GL applied for
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MINI Analog power terminal blocks
MINI MCR-SL-PTB-FM1) 2902958 1
MINI MCR-SL-PTB-FM-SP1) 2902959 1
Accessories
Error message modules
IN 1 2 OUT
Fault monitoring module for evaluating OUT RC
+ 1 5 +
and reporting group errors from the fault +24V PWR 1 FAULT
IN CONTACT
monitoring system. – 2
OUT RC
6 –
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MINI Analog error message modules
Standard configuration Screw connection MINI MCR-SL-FM-RC-NC1) 2902961 1
Standard configuration Spring-cage conn. MINI MCR-SL-FM-RC-SP-NC1) 2902962 1
Ordering data
Pcs. /
Description Type Order No.
Pkt.
DIN rail connector (TBUS), for bridging the supply voltage, can be
snapped onto 35 mm DIN rails as per EN 60715, with UL approval
Accessories
Power terminals
IN IN
– For supplying the supply voltage via the
+ 1 5
+
foot element (T-Connector) where DC +24V PWR 1 IN PWR 2 IN +24V
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR power terminal block
MINI MCR-SL-PTB1) 2864134 1
MINI MCR-SL-PTB-SP1) 2864147 1
90 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Accessories
ME 17,5 TBUS-...T-Connector
Ordering data
Pcs. /
Description Type Order No.
Pkt.
DIN rail connector, for bridging the supply voltage, can be
snapped onto 35 mm DIN rails as per EN 60715, with UL approval,
two pieces are required per system power supply
Accessories
System power supply H
D W
– For supplying the supply voltage via the
foot element (T-Connector) where AC
voltages are available
– 100 ... 240 V AC nominal input voltage
range
– 24 V DC output voltage
– For up to 60 MINI Analog modules
– For up to 1.5 A, secondary
– Status and error signaling via diagnostic
LEDs For applications with local voltages of
over 100 V
Ordering data
Pcs. /
Description Type Order No.
Pkt.
System power supply unit, primary-switched with zone 2 approval.
More information is given in the INTERFACE Power Supply catalog
part.
MINI-PS-100-240AC/24DC/1.5/EX 2866653 1
System power supply unit, primary-switched (not for zone 2).
More information is given in the INTERFACE Power Supply catalog
part.
MINI-SYS-PS-100-240AC/24DC/1.5 2866983 1
System cabling without a front adapter Front adapter for analog card
The version that does not require the
use of a front adapter is the ideal addition.
This solution involves using a 16-pos. System cabling with a front adapter
Controller Analog card Front adapter FLK cable V8 system adapter for MINI Analog
Siemens 6ES7-331-7KF02-0AB0
SIMATIC S7-300 / 6ES7-331-7KB02-0AB0
ET 200 M FLKM 16-PA-S300/MINI-MCR
6ES7-331-7KB81-0AB0 (in the catalog on page 454)
6ES7-331-7TF00-0AB0 FLK 16/EZ-DR/.../KONFEK
(non-molded plugs, MINI MCR-SL-V8-FLK 16-A
6ES7-332-8TF01-0AB0 (in the catalog on page 94)
in the catalog on page 506)
6ES7-331-1KF01-0AB0 FLKM 16-PA-331-1KF/I/MINI-MCR
(for current signals) (in the catalog on page 455)
6ES7-331-5HF00-0AB0 FLKM 16-PA-332-5HF/I/MINI-MCR
(for current signals) (in the catalog on page 455)
CABLE-FLK16/OE/0,14/...M
(non-molded plugs,
in the catalog on page 502)
Miscellaneous controllers / MINI MCR-SL-V8-FLK 16-A
All cards Not required or alternatively
actuators / sensors (in the catalog on page 94)
VIP-CAB-FLK16/FR/OE/0,14/...M
(molded plugs,
in the catalog on page 502)
92 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
V8 system adapter
for MINI Analog
Plug-in connection
Innovative concept
Increased protection
Addition
System adapter
Ex:
Housing width 50.4 mm
Technical data
General data
Contact resistance < 10 mΩ
Current carrying capacity ≤1A
Test voltage 500 V (50 Hz, 1 min. from channel to channel)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
System adapter, for MINI analog modules with screw connection
94 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Accessories
MINI Analog multiplexer
1xIOUT POWER
IN 8xIIN OUT
3xDO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PWR I D1+ D1- D2+ D2- D3+ D3-
In Out
Ex:
FLK pin strip assignment Housing width 50.4 mm
Technical data
Input data
Description 2, 4, 6, or 8-channel (can be switched over)
– Generates an analog output from up to Can be configured/parameterized Via DIP switches
eight analog input signals – parallel analog Input signal 4 ... 20 mA
Maximum input signal < 30 mA
signals are transmitted serially via a cable Switching cycles 2 or 1 sec. (can be selected)
– The desired number of channels is select- Output data
Output signal 4 ... 20 mA
ed via DIP switches (8, 6, 4 or 2 channels) Maximum output signal < 30 mA
– The channel currently switched is indicat- Load RB ((Usupply - 7 V) / I max)
ed as a bit pattern via three digital outputs Status indication Active input 1, 2, 3-bit digital output (can be selected)
Switching output 3 x PNP optocouplers
– Two clock cycles for execution can be se- Maximum switching voltage 30 V DC
lected via DIP switches (one- or two-sec- General data
ond clock) Supply voltage UB 7 V DC ... 30 V DC (Loop-powered)
Current consumption < 3.5 mA (without signal current)
– Supplied by an output loop Power consumption < 24 mW (without signal current)
– For 4 ... 20 mA current signals Maximum transmission error 0.3% (0.1%, typical)
Temperature coefficient < 0.01%/K
– Can be easily snapped onto MINI Analog Ambient temperature (operation) -20°C ... 65°C
modules with screw connection method Housing material PBT
– Huge reduction in analog inputs at con- Dimensions W / H / D 50.4 / 45.5 / 46.2 mm
Connection to control level Flat-ribbon cable plug connector according to IEC 60603-13
trollers
– System cabling on the output side using Insertion/withdrawal cycles ( System adapter / FLK 16 ) 10 / ≥ 200
Conformance / approvals
pre-assembled FLK cables with open Conformance CE-compliant
ends. ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada UL 508 Recognized applied for
Notes: Class I, Div. 2, Groups A, B, C, D T5 applied for
For six, four or two channels you will also need the corresponding Ordering data
number of feed-through terminal blocks (i.e., two, four or six).
1) EMC: Class A product, see page 571 Pcs. /
Description Type Order No.
Pkt.
Multiplexer for MINI Analog modules with screw connection
Accessories
MINI Analog feed-through terminal block MINI MCR-SL-TB 2811420 1
For round cable with one open end, see VIP-CAB-FLK16/FR/OE/0,14/...
“System cabling for controllers” section
For round cable with one open end, see CABLE-FLK16/OE/0,14/...
“System cabling for controllers” section
1 x Analog IN
Controller
8 x Analog IN
Power
MINI MCR-SL-MUX..
MINI MCR-SL-PT100-UI
MINI MCR-SL-PT100-UI AO
MINI MCR-SL-PT100-UI
MINI MCR-SL-PT100-UI 4...20 mA
MINI MCR-SL-PT100-UI
....
MINI MCR-SL-PT100-UI DO
00
MINI MCR-SL-PT100-UI DO
t0 l1
MINI MCR-SL-PT100-UI DO
Bi nne
a
Ch ve
ti
Ac Controller
3 x Digital IN
The TC-D37SUB-ADIO16-M-P-UNI
universal termination carrier is a compact
solution which connects isolating amplifiers
from the MINI Analog series to input/out-
put cards of automation systems.
The TC-D37SUB-AIO16-M-PS-UNI
termination carrier version also enables the
coupling and decoupling of HART signals.
– Connection of up to 16 channels
– Can be universally connected, thanks to
37-pos. D-SUB cable with open ends. This
enables flexible connection to automa-
tion systems
– Redundant power supply, decoupled from Housing width 136 mm
diode via separate MINI MCR-PTB power Technical data
module and MINI MCR-SL-TB feed- General data
through terminal block Connection to the control system level D-SUB pin strip
Number of positions 37
Notes: Maximum operating voltage < 50 V DC (Per signal/channel)
Contact us: together, we can develop optimum solutions for your Maximum permissible current 1 A (Signal/channel)
automation system with the termination carrier for MINI Analog. Rated insulation voltage 50 V
Surge voltage category II
1) EMC: Class A product, see page 571
Pollution degree 2
Rated surge voltage 0.5 kV
Air and creepage distances DIN EN 50178 ( Basic insulation )
Degree of protection IP20
Ambient temperature range -40°C ... 80°C (Please observe module specifications)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Module carrier for 16 MINI Analog channels, power and
feed-through module
TC-D37SUB-ADIO16-M-P-UNI 2902933 1
- With connection for MACX MCR-S-MUX HART multiplexer TC-D37SUB-AIO16-M-PS-UNI1) 2902934 1
Accessories
MINI Analog power terminal blocks MINI MCR-SL-PTB-FM1) 2902958 1
MINI Analog error message modules MINI MCR-SL-FM-RC-NC1) 2902961 1
HART multiplexer, 32-chanel, including two 14-wire flat-ribbon MACX MCR-S-MUX 2865599 1
cables
Alarm
X20 COMBICON
4 (-) PW1
6 (-) PW2
X1 DSUB 37
3 (+)
5 (+)
17
18
36
37
20
21
22
23
24
25
26
27
28
10
29
11
30
12
31
13
32
14
33
15
34
16
35
1
2
3
4
5
6
7
8
9
1
2
F1
F2
CH11
CH13
CH15
CH10
CH12
CH14
CH16
CH1
CH3
CH5
CH7
CH9
CH2
CH4
CH6
CH8
PTB
FM
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
PTSM
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
1
T-BUS
MINI PTB
2811420
PW1 2864134
MINI TB
-
+
Available 16-pos. VIP... round cables V8 system adapter for MINI Analog
98 PHOENIX CONTACT
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Highly compact isolating amplifiers - MINI Analog
Safe and reliable functions Precise transmission and high Easy configuration
– Consistent SIL certification. This ensures operational reliability – Without software via DIP switches on the
the highest level of reliability and safety – Thanks to patented transmission concept device front or with the operator inter-
for your systems. face and display unit.
Precise transmission, long service life Even for the Ex area Fast and error-free signal connection
– Patented circuit concepts ensure precise – Maximum explosion protection for all Ex – Compact termination carriers connect
signal transmission and minimal self-heat- zones with the MACX Analog Ex range. MACX Analog devices to the automation
ing. system – plug and play.
4.1
4-wire
US ±50 mV... ±1000 mV
[mA]
5.2 ±1 mA... ±5 mA - 3.2 -
4.2 3.2
active + passive
±10 mA... ±100 mA +
4.1 3.1 3.1
4-wire 4.2 +
US GND
[mV] 5.2 2.2 2.2
5.2 passive
±1 V... ±100 V active
5.1 2.1
-
2.1
GND
IN U,I U,I OUT 4-wire 5.1 1.2
US
[V] +24 V
5.2 1.1 Universal,
POWER more than 1600 signal combinations
GND +24 V
Zone 2
Div. 2
Functional safety
Ex: // Applied for: cUL / UL
Housing width 12.5 mm
Technical data
Input data U input I input
Input signal (configurable using the DIP switch) 0 ... 10 V, please indicate if different setting when ordering
Universal isolating amplifier for operating
Maximum input signal ±100 V ±100 mA
4-conductor measuring transducers Input resistance Approx. 1 MΩ Approx. 10 Ω
(±1 V DC ... ±100 V DC) (±10 mA DC ... ±100 mA DC)
– Analog isolating amplifier for isolating, fil- Output data U output I output
Output signal (configurable using the DIP switch) 0 ... 20 mA, please indicate if different setting when ordering
tering, amplifying, and converting stan-
dard analog signals Load RB ≥ 1 kΩ (10 V) ≤ 600 Ω (20 mA; active)
(passive: ≤ (UB-2 V) / Ioutmax)
– Configurable input and output signals, in- General data
cluding bipolar current and voltage signals Supply voltage UB 12 V DC ... 24 V DC (-20% / +25%)
Power dissipation < 0.7 W (at 24 V DC / 20 mA)
– 3-way electrical isolation Maximum transmission error ≤ 0.1% (Compared to the final value)
– Over 1600 signal conversions can be set Temperature coefficient 0.0075%/K
via DIP switches on the front ZERO / SPAN adjustment ±4% / ±4%
Limit frequency (3 dB) 10 kHz (Can be switched to 30 Hz)
– 10 kHz limit frequency for time-critical Step response (10 - 90%) 35 µs (at 10 kHz)
applications 11 ms (at 30 Hz)
Electrical isolation
– Output active or passive Input/output/power supply 2.5 kV (50 Hz, 1 min., test voltage)
– Plug-in capable screw or spring-cage con- 300 Vrms (Rated insulation voltage,
surge voltage category II; pollution degree 2,
nection method safe isolation as per EN 61010, EN 50178)
– Power supply via DIN rail connector pos-
Degree of protection IP20
sible Ambient temperature (operation) -20°C ... 70°C
– Status indicator for supply voltage Mounting Any
– Up to SIL 2 according to EN 61508 Housing material PA 66-FR
Dimensions W / H / D 12.5 / 99 / 114.5 mm
– Installation in zone 2 permissible Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Notes:
Conformance / approvals
To order a product with an order configuration, enter the required Conformance CE-compliant
configuration by referring to the adjacent order key. ATEX II 3 G Ex nA IIC T4 Gc
Information about the supply and error evaluation module as well IECEx Ex nA IIC T4 Gc
as about the DIN rail connectors and marking material can be UL, USA / Canada UL applied for
found from page 126 Functional safety (SIL) SIL 2
1) EMC: Class A product, see page 571 GL -
Ordering data
Pcs. /
Description Type Order No.
Pkt.
3-way isolating amplifier, for electrical isolation of analog signals
IN40 = 0...50 mV IN53 = -50...+50 mV IN70 = 0...1.0 mA OUT19 = 0...2.5 V OUT15 = 0...5 mA 30 = 30 Hz NONE = without FCC
2811284 = IN24 = 0...60 mV IN13 = -60...+60 mV IN71 = 0...1.5 mA OUT05 = 0...5 V OUT16 = 0...10 mA 10K = 10 kHz YES = with FCC (a fee
...-UI-UI IN41 = 0...75 mV IN54 = -75...+75 mV IN72 = 0...2.0 mA OUT03 = 0...10 V OUT01 = 0...20 mA is charged)
IN25 = 0...100 mV IN14 = -100...+100 mV IN73 = 0...3.0 mA
IN43 = 0...120 mV IN56 = -120...+120 mV IN36 = 0...5 mA OUT20 = -2.5...+2.5 V OUT21 = -5...+5 mA YESPLUS = FCC with
2811572 = IN44 = 0...150 mV IN57 = -150...+150 mV IN37 = 0...10 mA OUT13 = -5...+5 V OUT22 = -10...+10 mA 5 measuring
...-UI-UI-SP IN26 = 0...200 mV IN15 = -200...+200 mV IN74 = 0...15 mA OUT14 = -10...+10 V OUT23 = -20...+20 mA points (a fee is
IN27 = 0...300 mV IN16 = -300...+300 mV IN01 = 0...20 mA charged)
IN28 = 0...500 mV IN17 = -500...+500 mV IN75 = 0...30 mA OUT24 = 0.5...+2.5 V OUT25 = 1...5 mA
IN66 = 0...1000 mV IN78 = -1000...+1000 mV IN76 = 0...50 mA OUT06 = 1...5 V OUT26 = 2...10 mA
IN29 = 0...1.0 V IN18 = -1.0...+1.0 V IN77 = 0...100 mA OUT04 = 2...10 V OUT02 = 4...20 mA
IN50 = 0...1.5 V IN63 = -1.5...+1.5 V
IN30 = 0...2.0 V IN19 = -2.0...+2.0 V IN83 = -1.0...+1.0 mA OUT27 = 2.5...0 V OUT28 = 5...0 mA
IN52 = 0...3.0 V IN65 = -3.0...+3.0 V IN84 = -1.5...+1.5 mA OUT11 = 5...0 V OUT29 = 10...0 mA
IN05 = 0...5 V IN21 = -5...+5 V IN85 = -2.0...+2.0 mA OUT09 = 10...0 V OUT07 = 20...0 mA
IN03 = 0...10 V IN22 = -10...+10 V IN86 = -3.0...+3.0 mA
IN67 = 0...15 V IN79 = -15...+15 V IN33 = -5...+5 mA
IN32 = 0...20 V IN23 = -20...+20 V IN34 = -10...+10 mA
IN39 = 0...30 V IN80 = -30...+30 V IN87 = -15...+15 mA
IN68 = 0...50 V IN81 = -50...+50 V IN35 = -20...+20 mA
IN69 = 0...100 V IN82 = -100...+100 V IN88 = -30...+30 mA
IN89 = -50...+50 mA
IN90 = -100...+100 mA
MACX MCR-UI-UI
IN OUT
Level sensor ±50 mV... ±1000 mV
±1 mA... ±5 mA –
4.2 3.2
24 V 0...20 mA ±10 mA... ±100 mA
active +
4.1 3.1
GND
5.2 2.2
passive
±1 V... ±100 V
5.1 2.1
GND
1.2
+24 V
1.1
Controller
GND +24 V 24 V
Mains voltage
Application example: shunt measurement and Inline terminal with passive analog input channels within an Inline station
MACX MCR-UI-UI
M
IN OUT
±50 mV... ±1000 mV
±1 mA... ±5 mA –
4.2 3.2
active D
Shunt resistor ±10 mA... ±100 mA +
mV 4.1 3.1
AI2
GND
5.2 2.2
passive
±1 V... ±100 V 1 2
5.1 2.1
GND 1 1
1.2
+24 V
+ – 1.1 2 2
Battery 3 3
GND +24 V 24 V 4 4
Mains voltage
IB IL AI 2/SF
(Information on automation solutions from Phoenix Contact can be found in Catalog 8 or at www.phoenixcontact.net/products)
4.1
4-wire
US ±50 mV... ±1000 mV
[mA]
5.2 ±1 mA... ±5 mA - 3.2 -
4.2 3.2
active + passive
±10 mA... ±100 mA +
4.1 3.1 3.1
4-wire 4.2 +
US GND
[mV] 5.2 2.2 2.2
5.2 passive
±1 V... ±100 V active
5.1 2.1
-
2.1
IN U,I U,I OUT 4-wire 5.1 Power
1.2
US 24V ...230V AC/DC
[V]
5.2 1.1 Universal, more than 1600 signal combinations,
POWER wide-range power supply
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data U input I input
Input signal (configurable using the DIP switch) 0 ... 10 V, please indicate if different setting when ordering
– Analog isolating amplifier for isolating,
Maximum input signal ±100 V ±100 mA
filtering, amplifying, and converting stan- Input resistance Approx. 1 MΩ Approx. 10 Ω
dard analog signals (±1 V DC ... ±100 V DC) (±10 mA DC ... ±100 mA DC)
– Configurable input and output signals, in- Output data U output I output
Output signal (configurable using the DIP switch) 0 ... 20 mA, configurable via DIP switches
cluding bipolar current and voltage signals Maximum output signal 15 V 35 mA
– 3-way electrical isolation Load RB ≥ 1 kΩ (10 V) ≤ 600 Ω (20 mA; active)
(passive: ≤ (UB-2 V) / Ioutmax)
– Over 1600 signal conversions can be set General data
via DIP switches on the front Supply voltage UB 24 V ... 230 V AC/DC (-20%/+10%, 50/60 Hz)
– Output active or passive Power dissipation < 0.8 W (at 24 V DC / 20 mA)
< 0.9 W (At 230 V AC / 20 mA)
– Plug-in capable screw or spring-cage con- Maximum transmission error ≤ 0.1% (Compared to the final value)
nection method Temperature coefficient 0.0075%/K
ZERO / SPAN adjustment ±4% / ±4%
– Wide-range power supply: Electrical isolation
19.2 ... 253 V AC/DC Input/output/power supply 2.5 kV (50 Hz, 1 min., test voltage)
300 Vrms (Rated insulation voltage,
– Status indicator for supply voltage surge voltage category II; pollution degree 2,
– Up to SIL 2 according to EN 61508 safe isolation as per EN 61010, EN 50178)
– Installation in zone 2 permissible Degree of protection IP20
Ambient temperature (operation) -20°C ... 70°C
Notes:
Housing material PA 66-FR
To order a product with an order configuration, enter the required Dimensions W / H / D 12.5 / 99 / 114.5 mm
configuration by referring to the adjacent order key. Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
1) EMC: Class A product, see page 571 Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc
IECEx Ex nA IIC T4 Gc
UL, USA / Canada -
Functional safety (SIL) SIL 2
GL -
Ordering data
Pcs. /
Description Type Order No.
Pkt.
3-way isolating amplifier, for electrical isolation of analog signals
with long-range power supply
IN40 = 0...50 mV IN53 = -50...+50 mV IN70 = 0...1.0 mA OUT19 = 0...2.5 V OUT15 = 0...5 mA 30 = 30 Hz NONE = without FCC
2811459 = IN24 = 0...60 mV IN13 = -60...+60 mV IN71 = 0...1.5 mA OUT05 = 0...5 V OUT16 = 0...10 mA 10K = 10 kHz YES = with FCC (a fee
...-UI-UI-UP IN41 = 0...75 mV IN54 = -75...+75 mV IN72 = 0...2.0 mA OUT03 = 0...10 V OUT01 = 0...20 mA is charged)
IN25 = 0...100 mV IN14 = -100...+100 mV IN73 = 0...3.0 mA
IN43 = 0...120 mV IN56 = -120...+120 mV IN36 = 0...5 mA OUT20 = -2.5...+2.5 V OUT21 = -5...+5 mA YESPLUS = FCC with
2811585 = IN44 = 0...150 mV IN57 = -150...+150 mV IN37 = 0...10 mA OUT13 = -5...+5 V OUT22 = -10...+10 mA 5 measuring
...-UI-UI-UP-SP IN26 = 0...200 mV IN15 = -200...+200 mV IN74 = 0...15 mA OUT14 = -10...+10 V OUT23 = -20...+20 mA points (a fee is
IN27 = 0...300 mV IN16 = -300...+300 mV IN01 = 0...20 mA charged)
IN28 = 0...500 mV IN17 = -500...+500 mV IN75 = 0...30 mA OUT24 = 0.5...+2.5 V OUT25 = 1...5 mA
IN66 = 0...1000 mV IN78 = -1000...+1000 mV IN76 = 0...50 mA OUT06 = 1...5 V OUT26 = 2...10 mA
IN29 = 0...1.0 V IN18 = -1.0...+1.0 V IN77 = 0...100 mA OUT04 = 2...10 V OUT02 = 4...20 mA
IN50 = 0...1.5 V IN63 = -1.5...+1.5 V
IN30 = 0...2.0 V IN19 = -2.0...+2.0 V IN83 = -1.0...+1.0 mA OUT27 = 2.5...0 V OUT28 = 5...0 mA
IN52 = 0...3.0 V IN65 = -3.0...+3.0 V IN84 = -1.5...+1.5 mA OUT11 = 5...0 V OUT29 = 10...0 mA
IN05 = 0...5 V IN21 = -5...+5 V IN85 = -2.0...+2.0 mA OUT09 = 10...0 V OUT07 = 20...0 mA
IN03 = 0...10 V IN22 = -10...+10 V IN86 = -3.0...+3.0 mA
IN67 = 0...15 V IN79 = -15...+15 V IN33 = -5...+5 mA
IN32 = 0...20 V IN23 = -20...+20 V IN34 = -10...+10 mA
IN39 = 0...30 V IN80 = -30...+30 V IN87 = -15...+15 mA
IN68 = 0...50 V IN81 = -50...+50 V IN35 = -20...+20 mA
IN69 = 0...100 V IN82 = -100...+100 V IN88 = -30...+30 mA
IN89 = -50...+50 mA
IN90 = -100...+100 mA
MACX MCR-UI-UI-UP
IN OUT
Level sensor ±50mV... ±1000mV
±1mA... ±5mA –
4.2 3.2
24V 0...20mA ±10mA... ±100mA
active +
4.1 3.1
GND
5.2 2.2
passive
±1V... ±100V
5.1 2.1
Power
1.2
≃
24V ...230V AC/DC
1.1
Controller
Power
24V ...230V AC/DC
Application example: shunt measurement and Inline terminal with analog input channels within an Inline station
MACX MCR-UI-UI-UP
M
IN OUT
±50mV... ±1000mV
±1mA... ±5mA –
4.2 3.2
active D
Shunt resistor ±10mA... ±100mA +
mV 4.1 3.1
AI2
GND
5.2 2.2
passive
±1V... ±100V 1 2
5.1 2.1
1 1
Power
1.2
≃
24V ...230V AC/DC
+ – 1.1 2 2
Battery 3 3
4 4
Power
24V ...230V AC/DC
IB IL AI 2/SF
(Information on automation solutions from Phoenix Contact can be found in Catalog 8 or at www.phoenixcontact.net/products)
passive active
+
-
4.2 4.2 3.2 3.2 3.2
-
2-wire + +
4.1 4.1 3.1 3.1
-
2.2 2.2
5.2 5.2
US -
4-wire 2.1
+ 250 W
POWER 5.1 5.1
I I OUT GND
IN 1.2
Repeater power supply and
+24V
1.1
POWER Power
input isolating amplifier
GND +24V
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal 0 mA ... 20 mA / 4 mA ... 20 mA
Repeater power supply and input isolating Transmitter supply voltage > 16 V (at 20 mA)
amplifier for the operation of 2-conductor Voltage drop < 3.5 V (in input isolating amplifier operation)
Output data
measuring transducers, 4-conductor mea- Output signal 0 mA ... 20 mA (active)
suring transducers, and mA current sources 4 mA ... 20 mA (active)
0 mA ... 20 mA (14 ... 26 V ext. source voltage)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
– Input 0/4...20 mA (feeding or non-feeding) Load < 600 Ω
Output ripple < 20 mVrms
– 0/4...20 mA output (active or passive) General data
– Bidirectional transmission of digital HART Supply voltage range 19.2 V DC ... 30 V DC
communication signals Current consumption < 60 mA (at 24 V DC)
Power dissipation < 1.1 W (at 24 V DC / 20 mA)
– Plug-in capable screw or spring-cage con- Temperature coefficient < 0.01%/K
nection method, with integrated sockets Step response (10 - 90%) < 600 µs (for 4 mA ... 20 mA step)
Transmission error, typical < 0.05% (of final value)
for HART communicators Maximum transmission error < 0.1% (of final value)
– Terminal point with 250 Ω resistor to in- Under-/overload range as per NE 43
crease the HART impedance in the case Electrical isolation
Input/output/power supply 2.5 kV (50 Hz, 1 min., test voltage)
of low-impedance systems 300 Vrms (Rated insulation voltage,
– 3-way electrical isolation surge voltage category II; pollution degree 2,
safe isolation as per EN 61010, EN 50178)
– Power supply via DIN rail connector
possible Ambient temperature range -20°C ... 60°C (Any mounting position)
Status indication Green LED (supply voltage)
– Up to SIL 2 according to EN 61508 SMART communication Yes
– Installation in zone 2 permitted Signal bandwidth as per HART specifications
Protocols supported HART
Notes: Housing material PA 66-FR
Information about the supply and error evaluation module as well Dimensions W / H / D 12.5 / 99 / 114.5 mm
as about the DIN rail connectors and marking material can be Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
found from page 126 Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Conformance / approvals
Test plugs for test sockets can be found on page 191
Conformance CE-compliant, additionally EN 61326
Information on “Plug and play” connection using system cabling ATEX II 3 G Ex nA IIC T4 Gc X
can be found from page 128 UL, USA / Canada UL applied for
1) EMC: Class A product, see page 571 Functional safety (SIL) SIL 2 according to EN 61508
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Repeater power supply, with HARTR protocol
4.2 - 4.2 -
3.2 - 3.2
2-wire OUT 1 passive
+ + +
4.1 4.1 3.1 3.1
OUT1
-
2.2 2.2
OUT 2 passive
I +
5.2 - 5.2 2.1 2.1
POWER OUT2
US 4-wire
I I 5.1
+
5.1 GND
1.2
IN Repeater power supply and
+24V
1.1
POWER Power
input isolating amplifier,
with two electrically isolated outputs
GND +24V
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal 4 mA ... 20 mA / 0 mA ... 20 mA
Repeater power supply and input isolating Transmitter supply voltage > 21.5 V (at 20 mA)
amplifier for the operation of 2-conductor Voltage drop < 3.9 V (in input isolating amplifier operation)
– Up to SIL 2 according to EN 61508 Output 1/output 2 1.5 kV AC (50 Hz, 1 min., test voltage)
– Installation in zone 2 permitted Ambient temperature range -20°C ... 60°C (Any mounting position)
Status indication Green LED (PWR supply voltage)
Notes: SMART communication (Per output) Yes
Information about the supply and error evaluation module as well Protocols supported HART
as about the DIN rail connectors and marking material can be Housing material PA 66-FR
found from page 126 Dimensions W / H / D 12.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Test plugs for test sockets can be found on page 191
Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Information on “Plug and play” connection using system cabling Conformance / approvals
can be found from page 128 Conformance CE-compliant, additionally EN 61326
1) EMC: Class A product, see page 571 ATEX II 3 G Ex nA IIC T4 Gc X
Functional safety (SIL) SIL 2 according to EN 61508
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Repeater power supply, with HARTR protocol
active
-
4.3 3.3 3.3
S2
passive
- -
4.2 4.2 250 W 3.2 3.2 +
3.2
2-wire
+ S1 +
4.1 4.1 3.1 3.1
250 W
-
4.3
US 4-wire
POWER +
4.2
I I OUT
– 1.2
1.2 ~
IN Power –
~ Repeater power supply and
24V ...230V AC/DC
– 1.1
1.1 ~
POWER input isolating amplifier,
wide-range power supply
Zone 2
Div. 2
Functional safety
Ex:
Housing width 17.5 mm
Technical data
Input data
Input signal 0 mA ... 20 mA / 4 mA ... 20 mA
Repeater power supply and input isolating Transmitter supply voltage > 16 V (at 20 mA)
amplifier for the operation of 2-conductor Voltage drop < 3.5 V (in input isolating amplifier operation)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Repeater power supply, with HARTR protocol
active
-
-
4.2 - 4.2 3.2 - 3.2
P
+ + + +
4.1 4.1 3.1
3.1
-
4.2
+
4.1
I I
OUT IN GND
1.2
-
4.2
+24V
+ 1.1
POWER 4.1
Power
GND +24V
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal 0 mA ... 20 mA / 4 mA ... 20 mA
Output isolating amplifier for controlling Input voltage 5.4 V (at 20 mA)
I/P transducers, control valves, and displays Input impedance in the event of a cable break at the output > 100 kΩ (If there is a line fault)
Output data
– 0/4 ... 20 mA input Output signal 0 mA ... 20 mA / 4 mA ... 20 mA
Load < 800 Ω (at 20 mA)
– 0/4 ... 20 mA output Output ripple < 20 mVrms
– Bidirectional transmission of digital HART General data
communication signals Supply voltage range 19.2 V DC ... 30 V DC
Current consumption < 46 mA (at 24 V DC / 20 mA)
– Plug-in capable screw or spring-cage con- Power dissipation < 1.1 W (at 24 V DC / 20 mA)
nection method, with integrated sockets Temperature coefficient < 0.01%/K
Step response (10 - 90%) < 140 µs
for HART communicators Maximum transmission error < 0.1% (of final value)
– Line fault detection (LF) Electrical isolation
– 3-way electrical isolation Input/output/power supply 1.5 kV (50 Hz, 1 min., test voltage)
300 Vrms (Rated insulation voltage,
– Power supply via DIN rail connector surge voltage category II; pollution degree 2,
possible safe isolation as per EN 61010, EN 50178)
– Up to SIL 2 according to EN 61508 Ambient temperature range -20°C ... 60°C (Any mounting position)
– Installation in zone 2 permitted Humidity 10% ... 95% (no condensation)
SMART communication Yes
Notes: Signal bandwidth as per HART specifications
Protocols supported HART
Information about the supply and error evaluation module as well
Housing material PA 66-FR
as about the DIN rail connectors and marking material can be
found from page 126 Inflammability class according to UL 94 V0
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Test plugs for test sockets can be found on page 191 Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Information on “Plug and play” connection using system cabling Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
can be found from page 128 Conformance / approvals
1) EMC: Class A product, see page 571 Conformance CE-compliant, additionally EN 61326
ATEX II 3 G Ex nA IIC T4 Gc X
Functional safety (SIL) SIL 2 according to EN 61508
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Output isolating amplifier
Screw connection MACX MCR-SL-IDSI-I1) 2865971 1
Spring-cage conn. MACX MCR-SL-IDSI-I-SP1) 2924223 1
-
4.2 4.2 3.2 - 3.2
ϑ ϑ ϑ
μC μC passive
+ +
4.1 4.1 3.1 3.1
5.2 5.2
5.1 5.1
IN I OUT GND
1.2
+24V
1.1 For resistance thermometers and
Power
POWER resistance-type sensors
GND +24V
Zone 2
Div. 2
Ex:
Housing width 12.5 mm
Technical data
Input data
Resistance thermometers Pt, Ni, Cu sensors: 2, 3, 4-conductor
Programmable temperature transducer Resistor 0 Ω ... 2000 Ω
for operating resistance thermometers and Cable resistance 50 Ω per line
Sensor input current (200 μA ... 1 mA)
resistance-type sensors. The measured val- Measuring range span min. 50 K
ues are converted into a linear 0 ... 20 mA Output data
Output signal 0 mA ... 20 mA / 4 mA ... 20 mA
or 4 ... 20 mA signal. Load ≤ 500 Ω
Behavior in the event of a sensor error As per NE 43 or can be freely defined
– Input for resistance thermometers and Output ripple < 50 µAPP
General data
resistance-type sensors Supply voltage range 19.2 V DC ... 30 V DC
– 0 ... 20 mA or 4 ... 20 mA output Current consumption < 40 mA (24 V DC)
– Configuration via software (FDT/DTM): Power dissipation <1W
Temperature coefficient 0.01%/K
Sensor type, connection method, mea- Step response (0 - 99%) Typ. 800 ms (With SIL)
suring range, measuring unit, filter, alarm max. 1200 ms (With SIL)
Typ. 700 ms (Without SIL)
signal, and output range max. 1100 ms (Without SIL)
– Programming during operation and also volt- Transmission error, total 0.05% x 100 [K] / measuring range span [K] + 0.05%
Accessories
Programming adapter for configuring modules with IFS-USB-PROG-ADAPTER1) 2811271 1
S-PORT interface
Order key for MACX-MCR-SL-RTD-I(-SP) temperature transducer (standard configuration entered as an example)
Order No. Sensor type Safety integrity level Connection Measuring range: Measuring Output range Filter Filter
(SIL) technology Start End unit Oversampling Moving average value
2865065 = see below ON = active 2 = 2-conductor see be- see be- C = °C OUT01 = 0...20 mA 1 = 1 value 1 = 1 value
MACX MCR- NONE = not active low low F = °F 3 = 3 values 2 = 2 values
SL-RTD-I 3 = 3-conductor O = OUT02 = 4...20 mA 5 = 5 values 3 = 3 values
ON only with output range 7 = 7 values 4 = 4 values
2924317 = = OUT02 4 = 4-conductor 10 = 10 values
MACX MCR- 20 = 20 values
SL-RTD-I-SP Smallest measuring
range span
RES01 = Resistor 0 2000 25
PT50 = Pt 50 acc. to IEC 751 -200 850 °C 50 K
PT100 = Pt 100 acc. to IEC 751 -200 850 °C 50 K
PT200 = Pt 200 acc. to IEC 751 -200 850 °C 50 K
PT500 = Pt 500 acc. to IEC 751 -200 850 °C 50 K
PT100S = Pt 100 acc. to Sama RC21-4-1966 -200 600 °C 50 K
PT500S = Pt 500 acc. to Sama RC21-4-1966 -200 600 °C 50 K
NI100DIN = Ni 100 acc. to DIN 43760 -60 250 °C 50 K
NI500DIN = Ni 500 acc. to DIN 43760 -60 250 °C 50 K
CU50 = Cu 50 acc. to GOST 6651-2009 ( = 0.00428) -50 200 °C 50 K
CU53 = Cu 53 acc. to GOST 6651-2009 ( = 0.00426) -50 180 °C 50 K
-
4.2 4.2 3.2 - 3.2
-
µC µC passive
+ + +
4.1 4.1 3.1 3.1
IN I OUT GND
1.2
+24V
1.1 For thermocouples and mV sources
Power
POWER
GND +24V
Zone 2
Div. 2
Ex:
Housing width 12.5 mm
Technical data
Input data
Thermocouple sensors E, J, K, N as per IEC / EN 60584, L as per DIN 43760
Programmable temperature transducer
Voltage -20 mV ... 70 mV
for operating thermocouples and mV sourc- Measuring range span (Min. 50 K for thermocouples, 3 mV for mV sources)
es. The measured values are converted into
a linear 0 ... 20 or 4 ... 20 mA signal. Output data
Output signal 0 mA ... 20 mA / 4 mA ... 20 mA
Load max. 500 Ω
– Input for thermocouples and mV sources Behavior in the event of a sensor error As per NE 43 or can be freely defined
Output ripple < 50 µAPP
– 0 ... 20 mA or 4 ... 20 mA output General data
– Configuration via software (FDT/DTM): Supply voltage range 19.2 V DC ... 30 V DC
Sensor type, connection method, mea- Current consumption < 40 mA (24 V DC)
Power dissipation <1W
suring range, measuring unit, filter, alarm Temperature coefficient 0.01%/K
signal, and output range Step response (0 - 99%) Typ. 800 ms (With SIL)
max. 1200 ms (With SIL)
– Programming during operation and also volt- Typ. 700 ms (Without SIL)
age-free using IFS-USB-PROG-ADAPTER max. 1100 ms (Without SIL)
Transmission error, total 0.05% x 200 [K]/Measuring range span [K] + 0.05%
programming adapter
– Status indicator for supply voltage, cable, Cold junction errors ±1 K
sensor, and module errors ZERO / SPAN adjustment ±5% / ±5%
Electrical isolation
– 3-way electrical isolation Input/output/power supply 2.5 kV (50 Hz, 1 min., test voltage)
– Power supply via DIN rail connector 300 Vrms (Rated insulation voltage,
surge voltage category II; pollution degree 2,
possible safe isolation as per EN 61010, EN 50178)
– Up to SIL 2 according to EN 61508
Ambient temperature range -20°C ... 60°C (Any mounting position)
– Installation in zone 2 permitted Humidity 5% ... 95% (no condensation)
Housing material PA 66-FR
Notes: Inflammability class according to UL 94 V0
To order a product with an order configuration, enter the required Dimensions W / H / D 12.5 / 99 / 114.5 mm
configuration by referring to the adjacent order key. Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
The configuration software can be downloaded from the Internet Conformance / approvals
(www.phoenixcontact.net/products). Conformance CE-compliant, additionally EN 61326
Accessories
Programming adapter for configuring modules with IFS-USB-PROG-ADAPTER1) 2811271 1
S-PORT interface
Order key for MACX-MCR-SL-TC-I temperature transducer (standard configuration entered as an example)
Order No. Sensor type Safety integrity level Cold junction Measuring range: Measuring Output range Filter Filter
(SIL) compensation Start End unit Oversampling Moving average value
MACX MCR- see below ON = active 1 = switched on see be- see be- C = °C OUT01 = 0...20 mA 1 = 1 value 1 = 1 value
SL-TC-I NONE = not active low low F = °F 3 = 3 values 2 = 2 values
0 = switched off V = mV OUT02 = 4...20 mA 5 = 5 values 3 = 3 values
(e.g., for mV volt- 7 = 7 values 4 = 4 values
age measure- 10 = 10 values
ON only with output range ment) 20 = 20 values
= OUT02
Smallest measuring
range span
V03 = Voltage (mV) -20 +70 mV 3 mV
E = acc. to IEC 584-1 (NiCr-CuNi) -250 1000 °C 50 K
J = acc. to IEC 584-1 (Fe-CuNi) -210 1200 °C 50 K
K = acc. to IEC 584-1 (NiCr-Ni) -250 1372 °C 50 K
N = acc. to IEC 584-1 (NiCrSi-NiSi) -250 1300 °C 50 K
L = acc. to DIN 43760 (Fe-CuNi) -200 900 °C 50 K
passive
RTD
-
4.3 4.3 GND 3.3 3.3 3.3 -
S-PORT
TC ϑ
+
- 4.2 4.2 I OUT 3.2 3.2
ϑ +
+ 4.1 4.1 U OUT 3.1 3.1
µC
Poti
4.3 2.3 2.3 14
ϑ
4.2 2.2 2.2 11 DI
U,I 4.1 2.1 2.1 12
5.1 5.1
24V ...230V AC/DC
1.1
Universal, with switching output,
POWER wide-range power supply
Zone 2
Div. 2
Functional safety
Ex:
Housing width 17.5 mm
Technical data
Input data
Resistance thermometers Pt, Ni, Cu sensors: 2, 3, 4-conductor
Universal temperature transducer with Thermocouple sensors B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
freely configurable properties Resistor 0 Ω ... 50 kΩ
Potentiometer 0 Ω ... 50 kΩ
– Input for resistance thermometers, ther- Voltage -1000 mV ... 1000 mV
Output data U output I output
mocouples, resistance-type sensors, po- Output signal 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
tentiometers, and mV sources
Maximum output signal ±11 V 22 mA
– Measure differential temperatures Load RB ≥ 10 kΩ ≤ 600 Ω (20 mA)
– Freely programmable input and output Behavior in the event of a sensor error According to NE 43 or freely configurable
– Option of inverse output signal ranges Switching output Relay output
Contact type 1 PDT
– Relay switching output Contact material AgSnO2, hard gold-plated
– Configuration via software (FDT-DTM) or Maximum switching voltage 30 V AC (30 V DC)
IFS-OP-UNIT operating and display unit Maximum switching current 0.5 A (30 V AC) / 1 A (30 V DC)
General data
– Programming during operation and also Supply voltage range 24 V ... 230 V AC/DC (-20%/+10%, 50/60 Hz)
voltage-free using IFS-USB-PROG- Power consumption < 1.5 W
Temperature coefficient 0.01%/K
ADAPTER programming adapter Transmission error, total < 0.1% (e.g., for Pt 100, 300 K span, 4 ... 20 mA)
– Plug-in capable screw or spring-cage con- Electrical isolation
nection method Input/output/power supply 2.5 kV 1 (50 Hz, 1 min., test voltage)
300 Vrms (Rated insulation voltage,
– Cold junction compensation with sepa- surge voltage category II; pollution degree 2,
rate connector safe isolation as per EN 61010, EN 50178)
– Wide-range power supply: Input/output 375 V (Peak value in accordance with EN 60079-11)
19.2 ... 253 V AC/DC Input/power supply 375 V (Peak value in accordance with EN 60079-11)
Input/switching output 375 V (Peak value in accordance with EN 60079-11)
– Status indicator for supply voltage, cable, Ambient temperature range -20°C ... 65°C
sensor, and module errors Humidity Typ. 5% ... 95% (no condensation)
– Up to SIL 2 according to EN 61508 Housing material PA 66-FR
Inflammability class according to UL 94 V0
– Installation in zone 2 permitted Dimensions W / H / D 17.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Notes: Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
To order a product with an order configuration, enter the required Conformance / approvals
configuration by referring to the adjacent order key. Conformance CE-compliant
The configuration software can be downloaded from the Internet ATEX II 3 G Ex nA nC ic IIC T4 Gc X
(www.phoenixcontact.net/products). IECEx Ex nA nC ic IIC T4 Gc X
Functional safety (SIL) SIL 2, PL d
Information on the IFS-OP-UNIT operating and display unit and the
associated IFS-OP-CRADLE DIN rail cradle can be found on Ordering data
page 118
For information on the programming adapter, refer to page 119 Pcs. /
Description Type Order No.
Pkt.
1) EMC: Class A product, see page 571
Temperature transducer
Standard configuration Screw connection MACX MCR-T-UI-UP1) 2811394 1
Standard configuration Spring-cage conn. MACX MCR-T-UI-UP-SP1) 2811860 1
Order configuration Screw connection MACX MCR-T-UI-UP-C1) 2811873 1
Order configuration Spring-cage conn. MACX MCR-T-UI-UP-SP-C1) 2811970 1
Accessories
Programming adapter for configuring modules with IFS-USB-PROG-ADAPTER1) 2811271 1
S-PORT interface
Order No. Safety integrity level Sensor type Connection Cold junction com- Measuring range: Measuring Output range Factory calibration certificate
(SIL) technology pensation Start End unit = FCC
2811873 = ON = active see below 2 = 2-conductor 0 = off, e.g., with see be- see be- C = °C OUT15 = 0...5 mA NONE = without FCC
MACX MCR- RTD, R, potenti- low low F = °F OUT16 = 0...10 mA
T-UI-UP-C NONE = not active ometer, mV O = OUT01 = 0...20 mA
3 = 3-conductor P = % OUT15 = 0...5 mA YES = with FCC (a fee is
2811970 = V = mV OUT25 = 1...5 mA charged)
MACX MCR- ON only with output 1 = on, e.g., with TC OUT26 = 2...10 mA
T-UI-UP-SP-C range = OUT02 4 = 4-conductor OUT02 = 4...20 mA
OUT05 = 0...5 V YESPLUS = FCC with
OUT03 = 0...10 V 5 measuring points
OUT06 = 1...5 V (a fee is charged)
OUT04 = 2...10 V
OUT13 = -5...+5 V
OUT14 = -10...+10 V
Others can be freely
configured in the soft-
ware
Resistance thermometers (RTD) PT100 = Pt 100 acc. to IEC 751 -200 850 °C 20 K - Freely configurable user characteristic curve
Others can be selected or freely config- PT200 = Pt 200 acc. to IEC 751 -200 850 °C 20 K with 30 interpolation points
ured in the software. PT500 = Pt 500 acc. to IEC 751 -200 850 °C 20 K
PT1000 = Pt 1000 acc. to IEC 751 -200 850 °C 20 K - Output behavior in the event of a short circuit,
PT100S = Pt 100 acc. to Sama RC21-4-1966 -200 850 °C 20 K sensor break or overrange/underrange can be
freely configured or set according to NE43
PT1000S = Pt 1000 acc. to Sama RC21-4-1966 -200 850 °C 20 K
(standard configuration: NE43 upscale)
PT100G = Pt 100 acc. to GOST 6651-2009 ( = 0.00385) -200 850 °C 20 K
PT1000G = Pt 1000 acc. to GOST 6651-2009 ( = 0.00385) -200 850 °C 20 K - Filter setting (standard configuration: 1)
PT100J = Pt 100 acc. to JIS C1604/1997 -200 850 °C 20 K
PT1000J = Pt 1000 acc. to JIS C1604/1997 -200 850 °C 20 K - Restart after failsafe (standard configuration:
NI100 = Ni 100 acc. to DIN 43760/DIN IEC 60751 -60 250 °C 20 K ON)
NI1000 = Ni 1000 acc. to DIN 43760/DIN IEC 60751 -60 250 °C 20 K
NI100S = Ni 100 acc. to Sama RC21-4-1966 -60 180 °C 20 K - Switching behavior: switching output ?
NI1000S = Ni 1000 acc. to Sama RC21-4-1966 -60 180 °C 20 K (limit values, times, etc.) (standard configura-
NI1000L = Ni 1000 (Landis & Gyr) -50 160 °C 20 K tion: OFF)
CU10 = Cu 10 acc. to Sama RC21-4-1966 -70 500 °C 100 K
CU50 = Cu50 acc. to GOST 6651-2009 ( = 0.00428) -50 200 °C 100 K
CU100 = Cu100 acc. to GOST 6651-2009 ( = 0.00428) -50 200 °C 100 K
CU53 = Cu53 acc. to GOST 6651-2009 ( = 0.00426) -50 180 °C 100 K
KTY81 = KTY81-110 (Philips) -55 150 °C 20 K
KTY84 = KTY84-130 (Philips) -40 300 °C 20 K
Voltage signals (mV) V04 = Voltage (mV) -1000 +1000 mV 10% of nominal
Others can be selected in the software. span
9
Temperature conversion guide for °C to °F: T [°F] = – T [°C] + 32
5
passive
RTD -
3.3 3.3 -
TC ϑ
4.3 4.3 GND 3.3
+
+ 3.2
- 4.2 4.2 I OUT 3.2
ϑ 3.1
+ 4.1 4.1 U OUT 3.1
Poti 3x 3.6 34
4.3
ϑ
3.5 31 DI
4.2
3.4 32
U,I 4.1
2.6 24
5.3 5.3 NC 1.3
IN OUT 2.5 21 DI
5.2 5.2 Power 1.2
3x 5.1 5.1
24V ...230V AC/DC
1.1
2.4 22 Universal, with three limit value relays,
POWER wide-range power supply
1.6 14
1.5 11 DI
Zone 2
1.4 12 Functional safety
Div. 2
Ex:
Housing width 35 mm
Technical data
Input data
Resistance thermometers Pt, Ni, Cu sensors: 2, 3, 4-conductor
Universal temperature transducer with Thermocouple sensors B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
freely configurable properties Resistor 0 Ω ... 50 kΩ
Potentiometer 0 Ω ... 50 kΩ
– Input for resistance thermometers, ther- Voltage -1000 mV ... 1000 mV
Output data U output I output
mocouples, resistance-type sensors, po- Output signal 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
tentiometers, and mV sources
Maximum output signal ±11 V 22 mA
– Measure differential temperatures Load RB ≥ 10 kΩ ≤ 600 Ω (20 mA)
– Freely programmable input and output Behavior in the event of a sensor error According to NE 43 or freely configurable
– Option of inverse output signal ranges Switching output Relay output
Contact type 3 PDTs
– Three limit value relays, can be used in Contact material AgSnO2, hard gold-plated
combination as a safe limit value relay Maximum switching voltage 250 V AC (250 V DC)
– Configuration via software (FDT-DTM) or Maximum switching current 2 A (250 V AC) / 2 A (28 V DC)
General data
IFS-OP-UNIT operating and display unit Supply voltage range 24 V ... 230 V AC/DC (-20%/+10%, 50/60 Hz)
– Programming during operation and also Power consumption < 2.4 W
Temperature coefficient 0.01%/K
voltage-free using IFS-USB-PROG- Transmission error, total < 0.1% (e.g., for Pt 100, 300 K span, 4 ... 20 mA)
ADAPTER programming adapter Electrical isolation
– Plug-in capable screw or spring-cage con- Input/output/power supply 2.5 kV (50 Hz, 1 min., test voltage)
300 Vrms (Rated insulation voltage,
nection method surge voltage category II; pollution degree 2,
– Cold junction compensation with sepa- safe isolation as per EN 61010, EN 50178)
Accessories
Programming adapter for configuring modules with IFS-USB-PROG-ADAPTER1) 2811271 1
S-PORT interface
Order No. Safety integrity level Sensor type Connection Cold junction Measuring range: Measuring Output range Factory calibration
(SIL) technology compensation Start End unit certificate = FCC
2811514 = ON = active see below 2 = 2-conductor 0 = off, e.g., with see be- see be- C = °C OUT15 = 0...5 mA NONE = without FCC
MACX MCR- RTD, R, potenti- low low F = °F OUT16 = 0...10 mA
T-UIREL-UP-C NONE = not active ometer, mV O = OUT01 = 0...20 mA
3 = 3-conductor P = % OUT15 = 0...5 mA YES = with FCC (a fee is
2811831 = V = mV OUT25 = 1...5 mA charged)
MACX MCR- ON only with output 1 = on, e.g., with TC OUT26 = 2...10 mA
T-UIREL-UP-SP-C range = OUT02 4 = 4-conductor OUT02 = 4...20 mA
OUT05 = 0...5 V YESPLUS = FCC with
OUT03 = 0...10 V 5 measuring points
OUT06 = 1...5 V (a fee is charged)
OUT04 = 2...10 V
OUT13 = -5...+5 V
OUT14 = -10...+10 V
Others can be freely
configured in the soft-
ware
Resistance thermometers (RTD) PT100 = Pt 100 acc. to IEC 751 -200 850 °C 20 K - Freely configurable user characteristic curve
Others can be selected or freely config- PT200 = Pt 200 acc. to IEC 751 -200 850 °C 20 K with 30 interpolation points
ured in the software. PT500 = Pt 500 acc. to IEC 751 -200 850 °C 20 K
PT1000 = Pt 1000 acc. to IEC 751 -200 850 °C 20 K - Output behavior in the event of a short circuit,
PT100S = Pt 100 acc. to Sama RC21-4-1966 -200 850 °C 20 K sensor break or overrange/underrange can be
freely configured or set according to NE43
PT1000S = Pt 1000 acc. to Sama RC21-4-1966 -200 850 °C 20 K
(standard configuration: NE43 upscale)
PT100G = Pt 100 acc. to GOST 6651-2009 ( = 0.00385) -200 850 °C 20 K
PT1000G = Pt 1000 acc. to GOST 6651-2009 ( = 0.00385) -200 850 °C 20 K - Filter setting (standard configuration: 1)
PT100J = Pt 100 acc. to JIS C1604/1997 -200 850 °C 20 K
PT1000J = Pt 1000 acc. to JIS C1604/1997 -200 850 °C 20 K - Restart after failsafe (standard configuration:
NI100 = Ni 100 acc. to DIN 43760/DIN IEC 60751 -60 250 °C 20 K ON)
NI1000 = Ni 1000 acc. to DIN 43760/DIN IEC 60751 -60 250 °C 20 K
NI100S = Ni 100 acc. to Sama RC21-4-1966 -60 180 °C 20 K - Switching behavior: switching output ?
NI1000S = Ni 1000 acc. to Sama RC21-4-1966 -60 180 °C 20 K (limit values, times, etc.) (standard configura-
NI1000L = Ni 1000 (Landis & Gyr) -50 160 °C 20 K tion: OFF)
CU10 = Cu 10 acc. to Sama RC21-4-1966 -70 500 °C 100 K
CU50 = Cu 50 acc. to GOST 6651-2009 ( = 1.428) -50 200 °C 100 K
CU100 = Cu 100 acc. to GOST 6651-2009 ( = 1.428) -50 200 °C 100 K
CU53 = Cu 53 acc. to GOST 6651-2009 ( = 1.426) -50 180 °C 100 K
KTY81 = KTY81-110 (Philips) -55 150 °C 20 K
KTY84 = KTY84-130 (Philips) -40 300 °C 20 K
Voltage signals (mV) V04 = Voltage (mV) -1000 +1000 mV 10% of nominal
Others can be selected in the software. span
9
Temperature conversion guide for °C to °F: T [°F] = – T [°C] + 32
5
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Operating and display unit
IFS-OP-UNIT1) 2811899 1
Accessories
Cradle unit
Technical data
General data
Ambient temperature range -20°C ... 65°C (-4°F ... 149°F)
Humidity 90% (at 25°C, no condensation)
Housing material PA 6.6
Dimensions W / H / D 35.2 / 29 / 99 mm
Connection method IFS-OP-UNIT operator interface S port (socket)
Measuring transducer side S port (plug)
Conformance / approvals
Conformance CE-compliant
ATEX II 3G Ex nA ic IIC T4 Gc X
IECEx Ex nA ic IIC T4 Gc X
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Cradle unit, for snapping the operating and display unit onto the
DIN rail
IFS-OP-CRADLE1) 2811886 1
Applied for:
cUL / UL
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Programming adapter for configuring modules with
S-PORT interface
IFS-USB-PROG-ADAPTER1) 2811271 1
-
4.2 12
2.2 2.2
+
4.1
Faultsignal
IN OUT GND
1.2
4.2 +24V
1.1 Signal output: PDT relay
4.1 Power
POWER
LFD +24V
GND
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolation amplifier for operating Floating switch contacts
Switch contacts with resistance circuit
proximity sensors and mechanical contacts No-load voltage 8 V DC ±10%
Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
– Input for NAMUR proximity sensors Switching hysteresis < 0.2 mA
Line error detection Break 0.05 mA < IIN < 0.35 mA
(EN 60947-5-6), floating contacts or con- Short-circuit 100 Ω < RSensor < 360 Ω
tacts with resistance circuit Switching output Relay output
Contact type 1 PDT
– Relay signal output (PDT) Contact material AgSnO2, hard gold-plated
– Reversible direction of action (operating Maximum switching voltage 250 V AC (2 A) / 120 V DC (0.2 A) / 30 V DC (2 A)
current or closed-circuit current behavior) Maximum switching capacity 500 VA
Recommended minimum load 5 V / 10 mA
– Line fault detection (LFD), can be activat- Mechanical service life 107 cycles
ed/deactivated, error message signaled by Switching behavior Can be inverted via slide switch
Maximum switching frequency 20 Hz (without load)
red flashing LED with de-excitation of General data
output relay Supply voltage range 19.2 V DC ... 30 V DC
– Power supply and error indication possi- Current consumption 21 mA (24 V DC)
Power dissipation < 650 mW
ble via the DIN rail connector Electrical isolation
– LED displays for indicating supply voltage, Input/output/supply, T-Connector 300 Vrms (Rated insulation voltage,
surge voltage category II; pollution degree 2,
circuit state, and malfunctions to safe isolation as per EN 61010, EN 50178)
NAMUR NE 44 2.5 kV (50 Hz, 1 min., test voltage)
– 3-way electrical isolation Ambient temperature range -20°C ... 60°C (Any mounting position)
– Up to SIL 2 according to EN 61508 Humidity 10% ... 95% (no condensation)
– Installation in zone 2 permitted Housing material PA 66-FR
Inflammability class according to UL 94 V0
Notes: Dimensions W / H / D 12.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Information about the supply and error evaluation module as well Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
as about the DIN rail connectors and marking material can be
Conformance / approvals
found from page 126
Conformance CE-compliant, additionally EN 61326
Information about resistance circuits is given on page 183 ATEX II 3 G Ex nA nC IIC T4 Gc X
Information on “Plug and play” connection using system cabling Functional safety (SIL) SIL 2 according to EN 61508
can be found from page 128
Ordering data
1) EMC: Class A product, see page 571
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolation amplifier
Screw connection MACX MCR-SL-NAM-R1) 2865997 1
Spring-cage conn. MACX MCR-SL-NAM-R-SP1) 2924252 1
-
4.2 2.2 2.2 13
OUT2 DI
+
4.1
2.1 2.1 14
Faultsignal
IN OUT GND
1.2
4.2 +24V
1.1 2 signal outputs: N/O contact relay
4.1 Power
POWER
LFD +24V
GND
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolation amplifier for operating Floating switch contacts
Switch contacts with resistance circuit
proximity sensors and mechanical contacts No-load voltage 8 V DC ±10%
Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
– Input for NAMUR proximity sensors Switching hysteresis < 0.2 mA
Line error detection Break 0.05 mA < IIN < 0.35 mA
(EN 60947-5-6), floating contacts or con- Short-circuit 100 Ω < RSensor < 360 Ω
tacts with resistance circuit Switching output Relay output
Contact type 2 N/O contacts
– Two relay signal outputs (N/O contact); Contact material AgSnO2, hard gold-plated
output 2 can be used as an error message Maximum switching voltage 250 V AC (2 A) / 120 V DC (0.2 A) / 30 V DC (2 A)
output Maximum switching capacity 500 VA
Recommended minimum load 5 V / 10 mA
– Reversible direction of action (operating Mechanical service life 107 cycles
current or closed-circuit current behavior) Switching behavior Can be inverted via slide switch
Maximum switching frequency 20 Hz (without load)
– Line fault detection (LFD), can be activat- General data
ed/deactivated, error message signaled by Supply voltage range 19.2 V DC ... 30 V DC
red flashing LED with de-excitation of Current consumption 30 mA (24 V DC)
Power dissipation < 950 mW
output relay Electrical isolation
– Power supply and error indication possi- Input/supply, T connector 2.5 kV (50 Hz, 1 min., test voltage)
300 Vrms (Rated insulation voltage,
ble via the DIN rail connector surge voltage category II; pollution degree 2,
– LED displays for indicating supply voltage, safe isolation as per EN 61010, EN 50178)
circuit state, and malfunctions to Output 1/output 2/input, power supply, T connector 2.5 kV (50 Hz, 1 min., test voltage)
NAMUR NE 44 300 Vrms (Rated insulation voltage,
surge voltage category III; pollution degree 2,
– 4-way electrical isolation safe isolation as per EN 61010, EN 50178)
– Up to SIL 2 according to EN 61508
Ambient temperature range -20°C ... 60°C (Any mounting position)
– Installation in zone 2 permitted Humidity 10% ... 95% (no condensation)
Housing material PA 66-FR
Notes:
Inflammability class according to UL 94 V0
Information about the supply and error evaluation module as well Dimensions W / H / D 12.5 / 99 / 114.5 mm
as about the DIN rail connectors and marking material can be Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
found from page 126 Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Information about resistance circuits is given on page 183 Conformance / approvals
Conformance CE-compliant, additionally EN 61326
Information on “Plug and play” connection using system cabling
can be found from page 128 ATEX II 3 G Ex nA nC IIC T4 Gc X
Functional safety (SIL) SIL 2 according to EN 61508
1) EMC: Class A product, see page 571
Ordering data
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolation amplifier
Screw connection MACX MCR-SL-NAM-2RO1) 2865010 1
Spring-cage conn. MACX MCR-SL-NAM-2RO-SP1) 2924265 1
-
4.2 3.2 3.2 13
-
+ CH1 DI
+ 3.1 3.1 14
4.1
-
5.2 2.2 2.2 13
-
+ CH2 DI
2.1 2.1 14
IN1 OUT1 +
5.1
Faultsignal
IN2 - GND
OUT2 1.2
+24V
+ 1.1 2-channel, signal output: N/O contact relay
Power
POWER
LFD +24V
GND
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolating amplifier for intrinsical- Floating switch contacts
Switch contacts with resistance circuit
ly safe operation of proximity sensors and No-load voltage 8 V DC ±10%
mechanical contacts installed in Ex areas. Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
Switching hysteresis < 0.2 mA
Line error detection Break 0.05 mA < IIN < 0.35 mA
– 2-channel Short-circuit 100 Ω < RSensor < 360 Ω
– Input for NAMUR proximity sensors Switching output Relay output
Contact type 2 N/O contacts
(EN 60947-5-6), floating contacts or con- Contact material AgSnO2, hard gold-plated
tacts with resistance circuit Maximum switching voltage 250 V AC (2 A) / 120 V DC (0.2 A) / 30 V DC (2 A)
– Relay signal output (N/O contact) Maximum switching capacity 500 VA
Recommended minimum load 5 V / 10 mA
– Reversible direction of action (operating Mechanical service life 107 cycles
current or closed-circuit current behav- Switching behavior Can be inverted via slide switch
Maximum switching frequency 20 Hz (without load)
ior) General data
– Line fault detection (LFD), can be activat- Supply voltage range 19.2 V DC ... 30 V DC
ed/deactivated, error message signaled by Current consumption 35 mA (24 V DC)
Power dissipation <1W
red flashing LED with de-excitation of Electrical isolation
output relay Input/supply, T connector 2.5 kV (50 Hz, 1 min., test voltage)
300 Vrms (Rated insulation voltage,
– Power supply and error indication possi- surge voltage category II; pollution degree 2,
ble via the DIN rail connector safe isolation as per EN 61010, EN 50178)
– LED displays for indicating supply voltage, Output 1/output 2/input, power supply, T connector 2.5 kV (50 Hz, 1 min., test voltage)
circuit state, and malfunctions to 300 Vrms (Rated insulation voltage,
surge voltage category III; pollution degree 2,
NAMUR NE 44 safe isolation as per EN 61010, EN 50178)
– 3-way electrical isolation
Ambient temperature range -20°C ... 60°C (Any mounting position)
– Up to SIL 2 according to EN 61508 Humidity 5% ... 95% (no condensation)
– Installation in zone 2 permitted Housing material PA 66-FR
Inflammability class according to UL 94 V0
Notes: Dimensions W / H / D 12.5 / 99 / 114.5 mm
Information about the supply and error evaluation module as well Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
as about the DIN rail connectors and marking material can be Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
found from page 126 Conformance / approvals
Conformance CE-compliant, additionally EN 61326
Information about resistance circuits is given on page 183
ATEX II 3 G Ex nA nC IIC T4 Gc X
Information on “Plug and play” connection using system cabling Functional safety (SIL) SIL 2 according to EN 61508
can be found from page 128
1) EMC: Class A product, see page 571 Ordering data
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolation amplifier
Screw connection MACX MCR-SL-2NAM-RO1) 2865049 1
Spring-cage conn. MACX MCR-SL-2NAM-RO-SP1) 2924294 1
-
4.3 3.3 3.3 12
-
+ CH1 DI
+ 3.2 3.2 11
4.1
3.1 3.1 14
-
2.3 2.3 12
5.3
+ - DI
CH2 2.2 2.2 11
IN1 OUT1 +
5.1 2.1 2.1 14
IN2 -
OUT2 24...230 V –
1.2
~
+ AC/DC 2-channel, signal output: PDT relay,
1.1
Zone 2
Div. 2
Functional safety
Ex:
Housing width 17.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolation amplifier for operating open circuit switch contacts
Switch contacts with resistance circuit
proximity sensors and mechanical contacts No-load voltage 8 V DC ±10%
Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
– 2-channel Switching hysteresis Approx. 0.2 mA
Line error detection Break 0.05 mA < IIN < 0.35 mA
– Input for NAMUR proximity sensors Short-circuit 100 Ω < RSensor < 360 Ω
(EN 60947-5-6), floating contacts or con- Switching output Relay output
Contact type 2 PDT
tacts with resistance circuit Contact material AgSnO2, hard gold-plated
– Relay signal output (PDT) Maximum switching voltage 250 V AC (2 A, 60 Hz) / 120 V DC (0.2 A) / 30 V DC (2 A)
– Reversible direction of action (operating Maximum switching capacity 500 VA
Recommended minimum load 5 V / 10 mA
current or closed-circuit current behav- Mechanical service life 107 cycles
ior) Switching behavior can be inverted using DIP switch
Maximum switching frequency 20 Hz (Load-dependent)
– Line fault detection (LFD), can be activat- General data
ed/deactivated, error message signaled by Supply voltage range 24 V ... 230 V AC/DC (-20% ... +10%, 50 ... 60 Hz)
red flashing LED with de-excitation of
Current consumption < 80 mA ; < 42 mA (24 V DC)
output relay Power dissipation max. 1.3 W
– Wide-range power supply: Electrical isolation
Input/power supply 2.5 kV (50 Hz, 1 min., test voltage)
19.2 ... 253 V AC/DC 300 Vrms (Rated insulation voltage,
– LED displays for indicating supply voltage, surge voltage category II; pollution degree 2,
safe isolation as per EN 61010, EN 50178)
circuit state, and malfunctions to
NAMUR NE 44 Output 1/output 2/input, power supply 2.5 kV (50 Hz, 1 min., test voltage)
300 Vrms (Rated insulation voltage,
– 3-way electrical isolation surge voltage category III; pollution degree 2,
– Up to SIL 2 according to EN 61508 safe isolation as per EN 61010, EN 50178)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolation amplifier
Screw connection MACX MCR-SL-2NAM-R-UP1) 2865052 1
Spring-cage conn. MACX MCR-SL-2NAM-R-UP-SP1) 2924304 1
-
4.2 2.2 2.2 -
OUT2 DI
OUT1 +
4.1
2.1 2.1 +
Faultsignal
GND
IN OUT2 4.2
1.2
+24V
1.1 2 signal outputs: transistor (passive)
4.1 Power
POWER
LFD +24V
GND
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolation amplifier for operating Floating switch contacts
Switch contacts with resistance circuit
proximity sensors and mechanical contacts No-load voltage 8 V DC ±10%
Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
– Input for NAMUR proximity sensors Line error detection Break 0.05 mA < IIN < 0.35 mA
Short-circuit 100 Ω < RSensor < 360 Ω
(EN 60947-5-6), floating contacts or con- Switching output 2 transistor outputs, passive
tacts with resistance circuit Maximum switching voltage 30 V DC (per output)
Maximum switching current 50 mA (short-circuit resistant)
– 2 signal outputs: transistor (passive); up Drop (ΔU) < 1.4 V
to 5 kHz Switching behavior can be inverted using DIP switch
– Signal output 2 can also be used as a fault Maximum switching frequency 5 kHz
General data
signaling output Supply voltage range 19.2 V DC ... 30 V DC
– Reversible direction of action (operating Current consumption < 28 mA (24 V DC)
Power dissipation 800 mW
current or closed-circuit current behav- Electrical isolation
ior) Input/output/supply, T-Connector 300 Vrms (Rated insulation voltage,
– Line fault detection (LFD), can be activat- surge voltage category II; pollution degree 2,
safe isolation as per EN 61010, EN 50178)
ed/deactivated, error message signaled by 2.5 kV (50 Hz, 1 min., test voltage)
red flashing LED with inhibiting of transis- Output 1/output 2 1 kV (50 Hz, 1 min., test voltage)
tor output 50 Vrms (Rated insulation voltage,
surge voltage category II; pollution degree 2,
– Power supply and error indication possi- safe isolation as per EN 61010, EN 50178)
ble via the DIN rail connector
Ambient temperature range -20°C ... 60°C (Any mounting position)
– LED displays for indicating supply voltage, Humidity 10% ... 95% (no condensation)
circuit state, and malfunctions to Housing material PA 66-FR
NAMUR NE 44 Inflammability class according to UL 94 V0
Dimensions W / H / D 12.5 / 99 / 114.5 mm
– 4-way electrical isolation Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
– Up to SIL 2 according to EN 61508 Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
– Installation in zone 2 permitted Conformance / approvals
Conformance CE-compliant, additionally EN 61326
Notes: ATEX II 3 G Ex nA IIC T4 Gc X
Functional safety (SIL) SIL 2 according to EN 61508
Information about the supply and error evaluation module as well
as about the DIN rail connectors and marking material can be Ordering data
found from page 126
Information about resistance circuits is given on page 183 Pcs. /
Description Type Order No.
Pkt.
Information on “Plug and play” connection using system cabling
can be found from page 128 NAMUR isolation amplifier
Screw connection MACX MCR-SL-NAM-2T1) 2865023 1
1) EMC: Class A product, see page 571
Spring-cage conn. MACX MCR-SL-NAM-2T-SP1) 2924278 1
-
4.2 3.2 3.2 -
-
+ CH1 DI
+ 3.1 3.1 +
4.1
-
5.2 2.2 2.2 -
-
+ CH2 DI
2.1 2.1 +
IN1 OUT1 +
5.1
Faultsignal
IN2 - GND
OUT2 1.2
+24V
+ 1.1 2-channel, signal output transistor (passive)
Power
POWER
LFD +24V
GND
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolation amplifier for operating Floating switch contacts
Switch contacts with resistance circuit
proximity sensors and mechanical contacts No-load voltage 8 V DC ±10%
Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
– 2-channel Line error detection Break 0.05 mA < IIN < 0.35 mA
Short-circuit 100 Ω < RSensor < 360 Ω
– Input for NAMUR proximity sensors Switching output Transistor output, passive
(EN 60947-5-6), floating contacts or con- Maximum switching voltage 30 V DC (per output)
Maximum switching current 50 mA (short-circuit resistant)
tacts with resistance circuit Drop (ΔU) < 1.4 V
– Signal output transistor (passive); up to Switching behavior can be inverted using DIP switch
5 kHz Maximum switching frequency 5 kHz
General data
– Reversible direction of action (operating Supply voltage range 19.2 V DC ... 30 V DC
current or closed-circuit current behav- Current consumption < 34 mA (24 V DC)
Power dissipation 1000 mW
ior) Electrical isolation
– Line fault detection (LFD), can be activat- Input/output/supply, T-Connector 300 Vrms (Rated insulation voltage,
ed/deactivated, error message signaled by surge voltage category II; pollution degree 2,
safe isolation as per EN 61010, EN 50178)
red flashing LED with inhibiting of transis- 2.5 kV (50 Hz, 1 min., test voltage)
tor output Output 1/output 2 1 kV (50 Hz, 1 min., test voltage)
– Power supply and error indication possi- 50 Vrms (Rated insulation voltage,
surge voltage category II; pollution degree 2,
ble via the DIN rail connector safe isolation as per EN 61010, EN 50178)
– LED displays for indicating supply voltage,
Ambient temperature range -20°C ... 60°C (Any mounting position)
circuit state, and malfunctions to Humidity 10% ... 95% (no condensation)
NAMUR NE 44 Housing material PA 66-FR
– 3-way electrical isolation Inflammability class according to UL 94 V0
Dimensions W / H / D 12.5 / 99 / 114.5 mm
– Up to SIL 2 according to EN 61508 Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
– Installation in zone 2 permitted Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Conformance / approvals
Notes: Conformance CE-compliant, additionally EN 61326
Information about the supply and error evaluation module as well ATEX II 3 G Ex nA IIC T4 Gc X
as about the DIN rail connectors and marking material can be Functional safety (SIL) SIL 2 according to EN 61508
found from page 126
Ordering data
Information about resistance circuits is given on page 183
Information on “Plug and play” connection using system cabling Pcs. /
Description Type Order No.
can be found from page 128 Pkt.
Faultsignal
from diode, protected against polariza-
tion 1.2 –
PWR 1
– Supply current up to 3.75 A 1.1 +
– Relay output (PDT) and flashing LED for LFD +24V
GND
error messages
– Error message in the event of a power
supply failure or fuse fault
Ex: // Applied for: cUL / UL
– Bus cable fault message for Housing width 17.5 mm
MACX MCR-...(2)NAM... devices Technical data
connected via DIN rail connectors Input data
– Replaceable fuse Input signal 19.2 V DC ... 30 V DC
– Installation in zone 2 permissible Redundant supply yes, decoupled from diodes
Polarization and surge protection Yes
Output data
Maximum output signal 3.75 A
Output voltage (Input voltage - max 0.8 V at 3.75 A)
Switching output Relay
Contact type 1 PDT
Contact material Gold (Au)
Maximum switching voltage 50 V AC (2 A)
General data
Current consumption
Ambient temperature range -20°C ... 60°C (Any mounting position)
Humidity 5% ... 95% (no condensation)
Fuse 5 A (replaceable), slow-blow 250 V AC
Status indication 1 x red LED (error)
2 x green LEDs (PWR1 and PWR2)
Housing material Polyamide (PA 6.6)
Inflammability class according to UL 94 V0
Dimensions W / H / D 17.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X
IECEx Ex nA nC IIC T4 Gc X
UL, USA / Canada UL 61010
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Supply and error message module, including the relevant
DIN rail connector ME 17,5 TBUS 1,5/5-ST-3,81 GN
Ordering data
Pcs. /
Description Type Order No.
Pkt.
DIN rail connector (TBUS), for bridging the supply voltage, can be
snapped onto 35 mm DIN rails as per EN 60715, with UL approval
Accessories
Ordering data
Pcs. /
Description Color Type Order No.
Pkt.
UniCard, with self-adhesive plastic labels
The TC-D37SUB-ADIO16-EX-P-UNI
universal termination carrier is a compact
solution which connects isolating amplifiers
from the MACX Analog series to analog or
binary input/output cards of automation sys-
tems.
The TC-D37SUB-AIO16-EX-PS-UNI
termination carrier design, when combined
with the MACX MCR-S-MUX HART multi-
plexer, also enables communication be-
tween HART-capable field devices and a
management system.
– Connection of up to 16 single-channel
(Ex i-)isolating amplifiers Housing width 244 mm
– Universal 1:1 signal routing to a 37-pos. Technical data
D-SUB plug-in connector General data
– For system cables with D-SUB socket and Connection to the control system level D-SUB pin strip
open ends for universal connection Number of positions 37
Maximum operating voltage < 50 V DC (Per signal/channel)
– Redundant supply and monitoring in sep- Maximum permissible current 1 A (Signal/channel)
arate DIN rail module Rated insulation voltage 50 V
Surge voltage category II
Notes: Pollution degree 2
Contact us: specific termination carrier designs for I/O modules of Rated surge voltage 0.5 kV
various automation systems are available, planned or can be im- Air and creepage distances DIN EN 50178 ( Basic insulation )
plemented according to your specifications. Degree of protection IP20
Ambient temperature range -40°C ... 80°C (Please observe module specifications)
1) EMC: Class A product, see page 571
Shock 15g, according to IEC 60068-2-27
Vibration (operation) 2g, according to IEC 60068-2-6
Inflammability class according to UL 94 V0
Dimensions W / H / D 244 / 170 / 160 mm
Power supply via power module
Input voltage range 19.2 V DC ... 30 V DC
Redundant supply yes, decoupled from diodes
Polarization and surge protection Yes
Fuse 5 A Slow-blow (can be exchanged)
Status indication 1 x red LED (error)
2 x green LEDs (PWR1 and PWR2)
Switching output 1 PDT
Contact material Au
Maximum switching voltage 50 V DC (0.3 A) / 30 V DC (2 A) / 33 V AC (2 A)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Universal termination carrier for 16 MACX MCR-EX isolators
TC-D37SUB-ADIO16-EX-P-UNI 2924854 1
- With connection for MACX MCR-S-MUX HART multiplexer TC-D37SUB-AIO16-EX-PS-UNI1) 2902932 1
Accessories
Supply and error message module MACX MCR-PTB 2865625 1
MACX MCR-PTB-SP 2924184 1
HART multiplexer, 32-channel MACX MCR-S-MUX 2865599 1
X1 DSUB 37
X20 COMBICON
4 (-) PWR1
6 (-) PWR2
Alarm
3 (+)
5 (+)
20
21
22
23
24
25
26
27
28
10
29
11
30
12
31
13
32
14
33
15
34
16
35
1
9
1
2
CH10
CH11
CH12
CH13
CH14
CH15
CH16
PW1
PW2
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
PTSM
+
+
-
-
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
1.1
1.2
3.2
2.1
2.2
MACX
MCR-
PTB
IN OUT
Housing width 12.5 mm
Technical data
Input data U input I input
Input signal 0 ... 10 V / -10 ... 10 V 0 ... 20 mA / 4 ... 20 mA
– Processing standard signals Maximum input signal 30 V 50 mA
– Fixed setting of input and output signals Input resistance 100 kΩ 50 Ω
Output data U output I output
– 3-way isolation Output signal 0 ... 10 V / -10 ... 10 V 0 ... 20 mA / 4 ... 20 mA
Maximum output signal 15 V 30 mA
Notes: Load RB ≥ 10 kΩ ≤ 500 Ω
1) EMC: Class A product, see page 571 Linear transmission range 0% ... 105% -5% ... 105%
(in reference to the output range end value) -110% ... 110%
(Bipolar signals)
General data
Supply voltage UB 20 V DC ... 30 V DC
Current consumption < 15 mA (without load)
Maximum transmission error ≤ 0.3% (of final value), typ. < 0.2% (of final value)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR 3-way isolating amplifier, for electrical isolation of
analog signals,
Input signal Output signal
0 ... 10 V 4 ... 20 mA MCR-C-U-I- 4-DC1) 2814537 5
4 ... 20 mA 0 ... 10 V MCR-C-I-U- 4-DC1) 2814511 5
0 ... 10 V, -10 ... 10 V 0 ... 10 V, -10 ... 10 V MCR-C-U-U-DC1) 2814469 5
0 ... 20 mA, 4 ... 20 mA 0 ... 20 mA, 4 ... 20 mA MCR-C-I-I-00-DC1) 2814508 5
OUT OUT
OUT I2 1 7 OUT I1
A D
OUT U2 2 8 OUT U1
D A
OUT1 GND 2 3 9 GND 1
U,I
IN I 4 10 +24V DC
A
IN U,I U,I OUT2 IN U 5 11 GND 4
D
GND 3 6 12 GND 4
With freely configurable input and two outputs
IN
POWER
Ex:
Housing width 17.5 mm
Technical data
Input data U input I input
Input signal 0 V ... 12 V 0 mA ... 24 mA
– 4-way isolation (freely selectable in 0.1 V steps) (freely selectable in 0.1 mA
steps)
– Calibrated reversible input and output Measuring range span min. 4 V min. 8 mA
signals Maximum input signal 30 V 50 mA
Input resistance 200 kΩ 50 Ω
Notes: Output data U output I output
To order a product with an order configuration, enter the required Output signal (configurable using the DIP switch) refer to the order key refer to the order key
configuration by referring to the adjacent order key.
Maximum output signal 15 V 35 mA
1) EMC: Class A product, see page 571
Load RB ≥ 10 kΩ ≤ 600 Ω
General data
Supply voltage UB 20 V DC ... 30 V DC
Current consumption < 25 mA
Maximum transmission error ≤ 0.15% (of final value), typ. 0.05% (of final value)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR signal multiplier, for multiplication and electrical isolation of
analog signals,
Order configuration MCR-FL-C-UI-2UI-DCI1) 2814854 1
Standard configuration MCR-FL-C-UI-2UI-DCI-NC1) 2814867 1
Input signal (standard and special signals) Output signal (standard signals) Factory calibration
Order No. Input signal Initial value Final value Output 1 Output 2 certificate (FCC)
2814854 / I / 0.0 / 20.0 / OUT01 / OUT01 / NONE
I = Current 0.0 = 0.0 mA 20.0 = 20.0 mA OUT01 = 0...20 mA OUT01 = 0...20 mA NONE = without FCC
U = Voltage I : freely selectable between I : freely selectable between OUT02 = 4...20 mA OUT02 = 4...20 mA YES = with FCC (a fee
0.0 ... 24.0 mA 0.0 ... 24.0 mA OUT03 = 0...10 V OUT03 = 0...10 V is charged)
OUT04 = 2...10 V OUT04 = 2...10 V
U : freely selectable between U : freely selectable between OUT05 = 0...5 V OUT05 = 0...5 V YESPLUS = FCC with
0.0 ... 12.0 V 0.0 ... 12.0 V OUT06 = 1...5 V OUT06 = 1...5 V 5 measuring
OUT16 = 0...10 mA OUT16 = 0...10 mA points (a fee is
8.0 mA/4.0 V min. measuring range span charged)
0.1 mA/0.1 V increment
Ordering examples: Input signal (standard and special signals) Output signal (standard signals) Factory calibration certifi-
Initial value Final value Output 1 Output 2 cate (FCC)
2814854 / I / 5.3 / 13.3 / OUT01 / OUT01 / NONE
I = Current I = 5.3 mA I = 13.3 mA OUT01 = 0...20 mA OUT01 = 0...20 mA NONE = without FCC
U = Voltage U = 7.8 V U = 11.8 V OUT01 = 0...20 mA OUT03 = 0...10 V NONE = without FCC
Combination table for input and output signals that can be set via DIP switches
Output 1 Output 2
Input 0...20 mA 4...20 mA 0...10 mA 0...10 V 0...5 V 1...5 V 2...10 V 0...20 mA 4...20 mA 0...10 mA 0...10 V 0...5 V 1...5 V 2...10 V
0...20 mA x x x x x x x x x x x x x x
4...20 mA x x x x x x x x x x x x x x
0...10 mA x x x x x x x x x x x x x x
2...10 mA x x x x x x x x x x x x x x
0...10 V x x x x x x x x x x x x x x
2...10 V x x x x x x x x x x x x x x
0...5 V x x x x x x x x x x x x x x
1...5 V x x x x x x x x x x x x x x
Level sensor
0...20mA
5 U 2 U2 U1 8 GND 4 11
0...10V
15m3
24V
Mains voltage
IN OUT
Housing width 12.5 mm
Technical data
Input data
Input signal 0 ... 20 mA / 4 ... 20 mA
– Electrical isolation without additional Voltage drop 2.5 V (at I = 20 mA)
auxiliary power supply Response current < 50 µA
Maximum input current 50 mA (100 mA overload)
– Current signals 0(4)...20 mA Maximum input voltage 30 V (30 V overload)
– Safe isolation Input voltage limitation 33 V 5% (with Zener diode)
Output data
Notes: Output signal 0 ... 20 mA / 4 ... 20 mA
Maximum output signal < 50 mA
When using passive isolators, make sure that the current sourcing
voltage of the measuring transducer UB is sufficient to drive the Load RB ≤ 1375 Ω (at I = 20 mA output signal)
maximum current of 20 mA via the passive isolator with the voltage
drop UV = 2.5 V and the load RB. Ripple < 5 mV (rms)
This means: General data
UB ≥ UE = 2.5 V + 20 mA x RB Maximum transmission error ≤ 0.1% (of final value)
Additional error per 100 Ω load 0.02% (of measured value / 100 Ω load)
Temperature coefficient ≤ 0.002%/K (of measured value / 100 Ω load)
Test voltage input/output 4 kV (50 Hz, 1 min.)
Protection against electric shock Increased insulation according to DIN EN 61 010 part 1 and safe iso-
lation according to VDE 0100 part 410 along the lines of VDE 0106
part 101 up to 300 V AC/DC for surge voltage category II and pollu-
tion degree 2 between all isolated distances.
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR passive isolator, for electrical isolation of current signals
without auxiliary power
MCR-SL-1CLP-I-I-00-4KV 2814841 1
5
UV= 2,5 V
0 UE [Ω]
0 200 400 600 800 1000
IN OUT
Technical data
Input data
Input signal 0 ... 20 mA / 4 ... 20 mA
– Electrical isolation without additional Voltage drop 2.5 V (at I = 20 mA)
auxiliary power supply Response current < 50 µA
Maximum input current 50 mA (100 mA overload)
– Current signals 0(4)...20 mA Maximum input voltage 30 V (30 V overload)
– Alternatively 1-, 2- or 4-channel version Input voltage limitation 33 V (with Zener diode)
Output data
Notes: Output signal 0 ... 20 mA / 4 ... 20 mA
Maximum output signal < 50 mA
When using passive isolators, make sure that the current sourcing
voltage of the measuring transducer UB is sufficient to drive the Load RB ≤ 1375 Ω (at I = 20 mA output signal)
maximum current of 20 mA via the passive isolator with the voltage
drop UV = 2.5 V and the load RB. Ripple < 5 mV (rms)
This means: General data
UB ≥ UE = 2.5 V + 20 mA x RB Additional error per 100 Ω load 0.02% (of measured value)
Temperature coefficient ≤ 0.002%/K (of measured value / 100 Ω load)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR passive isolator, for electrical isolation of current signals
without auxiliary power
1-channel 12.5 mm wide MCR-1CLP-I-I-00 2814016 1
2-channel 12.5 mm wide MCR-2CLP-I-I-00 2814029 1
4-channel 22.5 mm wide MCR-4CLP-I-I-00 2814045 1
Flow measurement
UB
Magnetic inductive flow sensor
UV = 2,5 V
I
I 24V 0...20mA
UE RB 0...20mA
1 MCR-1CLP-I-I-00 5
I I I I
IN OUT
2 GND 1 GND 2 6
MCR-1CLP
Controller
IN OUT
1 D 7
C
2 D A 8
3 9
U,I 4 = 10 (+) 24VDC
IN OUT NC 5 = 11 SP
NC 6 12 (-) GND For resistance thermometers, thermocouples,
POWER resistance-type sensors, and mV sources
Ex:
Housing width 17.5 mm
Technical data
Input data
Resistance thermometers Pt, Ni, Cu sensors : 2, 3, 4-conductor
– For resistance thermometers and Thermocouple sensors U, T, L, J, E, K, N, S, R, B, C, W, HK
thermocouples Resistor 0 Ω ... 8000 Ω (freely adjustable, min. measuring range 100 Ω)
General data
Supply voltage UB 18 V DC ... 30 V DC
Current consumption ≤ 60 mA, typ. 40 mA
Maximum transmission error ≤ 0.1% (of maximum range, ±6 mV or ±12 µA at output)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducers, for resistance
thermometers and thermocouple sensors, with electrical isolation
of input/output and input/supply voltage
Sensor type Input characteristic curve Connection Measuring range: Measur- Output Output charac- Factory calibration
Order No. technology Start End ing unit teristic curve certificate (FCC)
2814113 / PT100 / D / 3 / -200.0 / +850.0 / C / OUT02 / N / NONE
See tables D = DIN 2 = 2-conductor for 0 mA for 20 mA C = °C OUT01 = 0...20 mA N = Normal NONE = without FCC
2814113 = under “Sen- S = SAMA (see table) 3 = 3-conductor (e.g., - (e.g., F = °F OUT02 = 4...20 mA I = Inverse YES = with FCC (a fee
MCR-T-UI-E sor type” 4 = 4-conductor 200.0°C) +850.0°C) V = mV OUT03 = 0...10 V is charged)
0 = for Ni1000 (Landis & Gyr), 0 = for O = W OUT05 = 0...5 V
2814090 = Cu10, Cu50, Cu53, thermocouple, P = % OUT13 = -5...+5 V YESPLUS = FCC with
MCR-T-UI KTY81-110, resistor, OUT14 = -10...+10 V 5 measuring
thermocouple, potentiometer, points (a fee is
resistor, voltage charged)
potentiometer,
voltage
Sensor type 1) Standard Measuring Smallest Sensor Thermocou- Measuring range Smallest Sensor Input Measuring range Smallest
(input charac- range measuring type ple measuring type measuring
teristic curve) range span range span range span
PT... DIN/SAMA -200°C ... 850°C 0.4 K U Cu-CuNi -200°C ... 600°C >1K RES Resistor 0 ... 8000 2
NI... DIN/SAMA -60°C ... 180°C 0.4 K T 2) Cu-CuNi -200°C ... 400°C >1K (2-conductor)
Ni1000 Landis & Gyr -50°C ... 160°C 0.4 K L Fe-CuNi -200°C ... 900°C >1K
2) POT Potentiometer 0 ... 100% 0.2%
CU10 SAMA -70°C ... 500°C 0.4 K J Fe-CuNi -210°C ... 1200°C >1K
2)
(max. 8 k) (3-conductor)
CU50 – -50°C ... 200°C 0.4 K E NiCr-CuNi -226°C ... 1000°C >1K
CU53 – -50°C ... 180°C 0.4 K K 2) NiCr-Ni -200°C ... 1372°C >1K V01 Voltage -20 mV ...+2400 mV 2 mV
KTY81 Philips -55°C ... 150°C 0.4 K N 2) NiCrSi-NiSi -200°C ... 1300°C >1K
KTY84 – -40°C ... 300°C 0.4 K S 2) Pt10Rh-Pt -50°C ... 1768°C >4K
R 2) Pt13Rh-Pt -50°C ... 1768°C >4K
Temperature ranges according to IEC 60751/EN 60751 and 2)
B Pt30Rh-Pt6Rh 500°C ... 1820°C > 10 K Temperature conversion guide for °C to °F:
DIN 43760 SAMA RC 21-4-1966 with 2, 3 or 4-conductor circuit.
1) Note: Pt sensors in increments of 10, 20, ...100 and
C -18°C ... 2316°C >4K 9
W -18°C ... 2316°C >4K T [°F] = – T [°C] + 32
100, 200, ...1000, 2000. 5
HK -200°C ... 800°C >1K
KTY81 = KTY81-110.
2) Thermocouples according to IEC 60584/EN 60584.
Other types or characteristic curves available on request.
Other types or characteristic curves available on request.
Application examples:
Resistance thermometer: 2-conductor connection tech- Resistance thermometer: 3-conductor connection tech- Resistance thermometer: 4-conductor connection tech-
nology nology nology
R L1 R L1 R L1
1 MCR-T-UI-E 7 10 +24 V DC 1 MCR-T-UI-E 10 +24 V DC
R, GND 2 8 GND
R L2 Mode Power R L2 4 1 MCR-T-UI-E 10 +24 V DC
Mode Power
3 9 12 3 9 12 R L2 2 11 GND
OUT I OUT U R L3 3 Mode Power
9 12
GND GND SP
R L3 Output:
Output: 0(4) ... 20 mA current signal 0 ... (5)10 V, (5)10 V voltage signal R L4 Output: switching output
Application: Application: Application:
• For short distances (< 10 m) • For long distances between the Pt 100 sensor and the MCR • For long distances between the Pt 100 sensor and the MCR
Please note: module (RL1, RL2, RL3 25 ) module and different cable resistances (R L1 RL2 RL3 RL4)
• Cable resistances RL1 and RL2 are incorporated in the measure- Please note: Please note:
ment result directly and falsify the result accordingly (example • To compensate the cable resistance, all cable resistances must • The cable resistance (RL2 + RL4) must not exceed a value of
for Pt 100: 0.385 = 1 K). have exactly the same values (RL1 = RL2 = RL3) 50 .
Compensation of 5% is possible.
IN OUT
1 U 7 OUT U/I
2 U 8
3 9 GND 1
4 = 10 (+) 24VDC
Shield 5 = 11 GND 2
IN U,I OUT
PT100 Shield 6 12 GND 2 For Pt 100, either voltage or current output
Power
POWER MM
Housing width 17.5 mm
Technical data
Input data
Resistance thermometers Pt 100 (IEC 60751/EN 60751) : 2, 3, 4-conductor
– Temperature range adjustable via Temperature range 0°C ... 300°C (0 ... 100/150/200/300) /
-50°C ... 250°C (-50 ... 50/100/150/250)
DIP switch Sensor input current Approx. 1 mA
– ZERO/SPAN adjustment Output data U output I output
– Open circuit detection Output signal 0 ... 10 V 0 ... 20 mA / 4 ... 20 mA
Maximum output signal 15 V 30 mA
– Alternatively with galvanically isolated Load RB ≥ 10 kΩ ≤ 500 Ω
supply voltage Output signal with open circuit > 11 V > 22 mA
General data ...-U-DC ...-I-DC ...-U ...-I
Notes: Supply voltage UB 20 ... 30 V DC 20 ... 30 V DC 20 ... 30 V DC 20 ... 30 V DC
When ordering, you must use the order key to specify the desired Current consumption 35 mA 60 mA 20 mA 45 mA
configuration. Maximum transmission error ≤ 0.4% (of final value)
Temperature coefficient ≤ 0.02%/K
1) EMC: Class A product, see page 571
ZERO / SPAN adjustment ±5% / ±5%
Step response (10 - 90%) 11 ms
Test voltage power supply/signal 750 V AC (50 Hz, 1 min.)
Ambient temperature (operation) -20°C ... 65°C
Housing material Polyamide PA non-reinforced
Dimensions W / H / D 17.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Conformance / approvals
Conformance CE-compliant
UL, USA / Canada UL 508 Recognized
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducer, for Pt 100 temperature
sensors with 2, 3, 4-conductor technology with electrically isolated
supply voltage
Output: 0..0.10 V MCR-PT100-U-DC1) 2810311 1
Output: 0...(4)20 mA MCR-PT100-I-DC1) 2810337 1
Output: 0...10 V, without electrical isolation MCR-PT100-U1) 2810340 1
IN OUT
SETPOINT
1 5 11
Pt 100
2 U 6 12
IN OUT
PT100 +24 VDC 3 DC 7 11
For Pt 100
GND 4 DC 8 14
POWER
Housing width 12.5 mm
Technical data
Input data
Resistance thermometers Pt 100 (IEC 60751/EN 60751) : 2-conductor
– Switching point in the temperature range Temperature range -100°C ... 700°C
from -100°C ... +700°C freely selectable Sensor input current Approx. 1 mA
Switching output Relay output
– Changeover relay output Contact type 1 PDT
– Galvanically isolated Contact material AgSnO, hard gold-plated
Maximum switching current 50 mA (for gold layer, 30 V AC/ 36 V DC)
– Adjustable switch hysteresis 2 A (in case of a destroyed gold layer, 250 V AC)
Operate delay time Approx. 6 ms
Notes:
Off delay time Approx. 200 ms
1) EMC: Class A product, see page 571 Switching hysteresis Adjustable using DIP switches (0.5 K, 2 K, 3 K, 5 K)
Error/status indicator Red LED (short-circuit/wire break) / Yellow LED (relay active)
General data
Supply voltage UB 20 V DC ... 30 V DC
Current consumption < 30 mA
Linearity error < 0.1%
Setting accuracy < 1%, typ. < 0.5%
Temperature coefficient < 0.01%/K, typ. 0.005%/K
Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
Ambient temperature (operation) -20°C ... 65°C
Mounting Any
Housing material Polyamide PA non-reinforced
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Conformance / approvals
Conformance CE-compliant
UL, USA / Canada UL 508 Recognized
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature relay, for Pt 100 in 2-conductor system
MCR-SL-PT100-SP1) 2814948 1
MCR-SL-PT100-SP
SP
ERROR
Pt 100 0
10
20
K
30
50
40
SETPOINT
IN
1 2
+24V
GND
3 4
24V
IN OUT
- 1 5 OUT I
DC D
C IN
2 D DC A 6 POWER
IN POWER 3
I
OUT Loop-powered,
+ 4
programmable
Ex:
Housing width 12.5 mm
Technical data
Input data
Resistance thermometers Pt, Ni (100, 500, 1000);
– Two-wire transmitter for resistance minimum measurement range 10 K : 2, 3, 4-conductor
Thermocouple sensors B, C, D, E, J, K, L, N, R, S, T, U;
thermometers, thermocouples, minimum measurement range 50 K/500 K
resistance-type, and voltage sensors Resistor (Resistance-type sensor from 10 Ω to 400 Ω and from 10 Ω to 2000 Ω;
minimum measurement range 10 Ω/100 Ω)
– Freely programmable via
MCR/PI-CONF-WIN Voltage -10 mV ... 100 mV (min. measurement range 5 mV)
Output data
Notes: Output signal 4 ... 20 mA / 20 ... 4 mA
The devices are supplied with the standard configuration: Load RB (Max (Vsupply -12 V) / 0.023 A (current output))
Pt 100 sensor, measuring range 0 ... 100°C, 3-cond. connection.
Output signal with short-circuit ≤ 3.6 mA or ≥ 21 mA (adjustable, not for thermocouples)
You can implement your own measuring range settings, lineariza-
tion, and characteristic curve adjustments. For this purpose, you
Output signal with open circuit ≤ 3.6 mA or ≥ 21 mA (adjustable)
need the MCR-PAC-T-USB programming adapter and the
MCR/PI-CONF-WIN configuration software, see page 149 Measuring range overrange/underrange ≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease)
General data
Supply voltage UB 12 V DC ... 35 V DC
Current consumption < 3.5 mA
Transmission error Resistance thermometers 0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000)
Thermocouple sensors Type 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R)
Resistance-type sensors ±0.1 Ω (10...400 Ω), ±1.5 Ω (10...2000 Ω)
Voltage sensor ±20 µV (-10...100 mV)
Step response (10 - 90%) <2s
Pickup delay 4s
Test voltage input/output 2 kV (50 Hz, 1 min.)
Degree of protection IP20
Ambient temperature (operation) -40°C ... 85°C
Mounting Any
Housing material Polyamide PA non-reinforced
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Conformance / approvals
Conformance CE-compliant
UL, USA / Canada Class I, Div. 2, Groups A, B, C, D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducer, loop-powered
IN OUT
1 DC D 5 OUT I
C IN
2 D DC A 6 POWER
IN POWER 3
I
PT100 OUT
4
Loop-powered,
programmable
Ex:
Housing width 12.5 mm
Technical data
Input data
Resistance thermometers Pt 100 ; minimum measurement range 10 K : 2, 3, 4-conductor
– Two-wire transmitter for
Output data
Pt 100 resistance thermometers Output signal 4 ... 20 mA / 20 ... 4 mA
– Freely programmable via Load RB (Max (Vsupply -12 V) / 0.023 A (current output))
MCR/PI-CONF-WIN
Output signal with short-circuit ≤ 3.6 mA or ≥ 21 mA (adjustable)
Notes: Output signal with open circuit ≤ 3.6 mA or ≥ 21 mA (adjustable)
Measuring range overrange/underrange ≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease)
The devices are supplied with the standard configuration:
Pt 100 sensor, measuring range 0 ... 100°C, 3-cond. connection. General data
You can implement your own measuring range settings, lineariza- Supply voltage UB 12 V DC ... 35 V DC
tion, and characteristic curve adjustments. For this purpose, you Current consumption < 3.5 mA
need the MCR-PAC-T-USB programming adapter and the Transmission error Resistance thermometers 0.2 K
MCR/PI-CONF-WIN configuration software, see page 149 Step response (10 - 90%) <2s
Pickup delay 4s
Test voltage input/output 2 kV (50 Hz, 1 min.)
Degree of protection IP20
Ambient temperature (operation) -40°C ... 85°C
Mounting Any
Housing material Polyamide PA non-reinforced
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 24
Conformance / approvals
Conformance CE-compliant
UL, USA / Canada Class I, Div. 2, Groups A, B, C, D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducer, loop-powered
IN OUT
3 DC D 1 OUT I
C IN
4 D DC A 2 POWER
IN POWER
I 5
OUT Loop-powered,
6
programmable
Ex:
Technical data
Input data
Resistance thermometers Pt, Ni (100, 500, 1000);
– Two-wire transmitter for resistance minimum measurement range 10 K : 2, 3, 4-conductor
Thermocouple sensors B, C, D, E, J, K, L, N, R, S, T, U;
thermometers, thermocouples, resis- minimum measurement range 50 K/500 K
tance-type, and voltage sensors Resistor (Resistance-type sensor from 10 Ω to 400 Ω and from 10 Ω to 2000 Ω;
minimum measurement range 10 Ω/100 Ω)
– For mounting in the connecting head,
form B Voltage -10 mV ... 75 mV (min. measurement range 5 mV)
– Freely programmable via Output data
Output signal 4 ... 20 mA / 20 ... 4 mA
MCR/PI-CONF-WIN Load RB (Max (Vsupply - 8 V) / 0.025 A (current output))
Notes: Output signal with short-circuit ≤ 3.6 mA or ≥ 21 mA (adjustable, not for thermocouples)
The devices are supplied with the standard configuration:
Pt 100 sensor, measuring range 0 ... 100°C, 3-cond. connection. Output signal with open circuit ≤ 3.6 mA or ≥ 21 mA (adjustable)
Measuring range overrange/underrange ≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease)
You can implement your own measuring range settings, lineariza-
tion, and characteristic curve adjustments. For this purpose, you
General data
need the MCR-PAC-T-USB programming adapter and the
MCR/PI-CONF-WIN configuration software, see page 149 Supply voltage UB 8 V DC ... 35 V DC
Current consumption < 3.5 mA
Transmission error Resistance thermometers 0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000)
Thermocouple sensors Type 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R)
Resistance-type sensors ±0.1 Ω (10...400 Ω), ±1.5 Ω (10...2000 Ω)
Voltage sensor ±20 µV (-10...100 mV)
Step response (10 - 90%) <2s
Pickup delay 6s
Test voltage input/output 2 kV (50 Hz, 1 min.)
Degree of protection IP00, IP66 (integrated in the connecting head)
Ambient temperature (operation) -40°C ... 85°C
Mounting Any
Housing material Polycarbonate, PC
Screw connection solid / stranded / AWG 0.2 ... 1.75 mm² / 0.2 ... 1.75 mm² / 24 - 15
Conformance / approvals
Conformance CE-compliant
UL, USA / Canada Class I, Div. 2, Groups A, B, C, D
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducer, loop-powered
∅44
∅33
4 5
∅5
3
6
∅7
1
21
IN OUT
3 D 1 OUT I
C IN
4 D A 2 POWER
IN POWER
I 5
PT100 OUT
6 Loop-powered,
programmable
Ex:
Technical data
Input data
Resistance thermometers Pt 100 ; minimum measurement range 10 K : 2, 3, 4-conductor
– Two-wire transmitter for Pt 100
Output data
resistance thermometers Output signal 4 ... 20 mA / 20 ... 4 mA
– For mounting in the connecting head, Load RB (Max (Vsupply - 10 V) / 0.023 A (current output))
form B
Output signal with short-circuit ≤ 3.6 mA or ≥ 21 mA (adjustable)
– Freely programmable via Output signal with open circuit ≤ 3.6 mA or ≥ 21 mA (adjustable)
MCR/PI-CONF-WIN Measuring range overrange/underrange ≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducer, loop-powered
∅44
∅33
4 5
∅5
3
6
∅7
1
21
+8,2 V
1 DC
DC
9 +24 V
Namur
2 IN
DC 10 GND
f in
3
4 GND 1 11 SW
NPN mC
PNP 5
NPN 12 GND
PNP
Dry 6 +15 V 13 NC
U,I Contact
IN OUT A D 14 I OUT
f,U,I U in
0-10 V 7 D A
Programmable,
A D 15 U OUT
POWER 0-20 mA 8
I in
D A 16 GND 2 for frequencies of up to 120 kHz
Ex:
Housing width 45 mm
Technical data
Input data Frequency input
Frequency range 0.1 Hz ... 120 kHz
– Frequencies up to 120 kHz Input sources NPN/PNP transistor outputs
NAMUR initiators
– For NAMUR sensors, floating contacts, Floating relay contact (dry contact)
frequency generators, and NPN/PNP Frequency generator
Transducer supply Approx. 15 V DC / max. 25 mA (constant)
transistor outputs Signal level 2 VPP (In case of rectangle 0.1 Hz ... 120 kHz)
– Analog and switching output 2 VPP (In case of sine 8 Hz ... 120 kHz)
13 VPP (In case of sine 1 Hz ... 120 kHz)
– 3-way isolation Maximum input signal 30 V (incl. DC voltage)
– Programmable using membrane keypad or Signal form Any
software Pulse length ≥ 1 µs
Resolution > 12 bit
– Display of input or output signal Signal conversion time ≤ 32 ms
Input data Isolating amplifier function
Notes:
Input signal 0 V ... 10 V (freely adjustable) 0 mA ... 20 mA (freely adjustable)
Further information about the configuration software can be found
on page 149 Maximum input signal 12 V 24 mA
1) EMC: Class A product, see page 571 Input resistance 95 kΩ 200 Ω
Resolution 14 bit (full-scale) 14 bit (full-scale)
Output data U output I output
Output signal 0 ... 5 V / 0 ... 10 V 0 ... 20 mA
Maximum output signal 12.5 V 25 mA
Load RB ≥ 500 Ω ≤ 500 Ω
Ripple < 20 mVPP
Switching output Transistor output, pnp
Switches supply voltage to terminal block SW, can carry a load of
100 mA, not protected against short-circuit
General data
Supply voltage UB 20 V DC ... 30 V DC
Current consumption < 60 mA (without load, without switching output)
Maximum transmission error ≤ 0.15% (of measured value), typ. 0.1%
Temperature coefficient 0.015%/K, typ. 0.01%/K
ZERO / SPAN adjustment ±25% / ±25%
Step response (10 - 90%) < 25 ms
Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.)
Ambient temperature (operation) -20°C ... 65°C (for specified data)
Status indication LC display
Operating elements Membrane keypad with 3 keys and LCD display
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR frequency measuring transducer, for conversion of
frequencies into analog signals 0(4)...20 mA, 0...(5)10 V and
their inverse signals
MCR-F-UI-DC1) 2814605 1
MCR-f-UI-DC
MCR-f-UI-DC
MCR-f-UI-DC
also possible instead
bu 2 NAMUR
IN
bu 2 NAMUR 2 NAMUR
of terminal block 6. IN bk
IN
3 f IN pnp bk 3 f IN 3 f IN
bu
4 GND1 4 GND1 4 GND1
NPN NPN NPN
5 PNP 5 PNP 5 PNP
6 +15 V bn 6 +15 V
6 +15 V
7 U IN 7 U IN 7 U IN
8 I IN 8 I IN 8 I IN
2-wire DC NAMUR sensor • With NPN transistor output • NPN transistor with pull-up resistance
bn bu
1 +8,2 V 1 +8,2 V 1 +8,2 V
MCR-f-UI-DC
MCR-f-UI-DC
MCR-f-UI-DC
4-wire DC Incremental rotary transducer with push-pull: Incremental rotary transducer with HTL logic:
• With PNP transistor output • Supply of the external signaling encoder • Supply of the external signaling encoder
bn
1 +8,2 V UB = 5-30 V DC 1 +8,2 V UB = 24 V DC 1 +8,2 V
MCR-f-UI-DC
MCR-f-UI-DC
• With NPN transistor output • Supply of the signaling encoder from the module • Supply of the signaling encoder from the module
bu
1 +8,2 V 15 V/25 mA 1 +8,2 V The external supply can 15 V/25 mA 1 +8,2 V
MCR-f-UI-DC
MCR-f-UI-DC
MCR-f-UI-DC
be picked off by
bn 2 NAMUR 2 NAMUR 2 NAMUR
IN
IN IN terminal blocks 9
npn bk 3 f IN 3 f IN +24VDC and 0 GND 3 f IN
wh 4 GND1 4 GND1 as well. 4 GND1
K1, K2, K0
NPN NPN Any 3-way isolation NPN
5 PNP 5 PNP 5 PNP
then no longer applies. K1, K2, K0
6 +15 V 6 +15 V 6 +15 V
7 U IN 7 U IN 7 U IN
8 I IN 8 I IN 8 I IN
4 11 SW
analog standard signal that provides NPN
PNP 5
GND 1
NPN
μC
12 GND
PNP 24 V
information about the numbers of bottles in Dry
Contact
6 +15 V 13 NC
NAMUR sensor
filling systems recorded in a defined time 0-10 V 7
U in
A
D
D
A
14 I OUT
Mains voltage
unit. 0-20 mA 8
I in
A
D
D
A
15 U OUT
16 GND 2
DC
DC
9 +24 V
10 GND
11 SW
GND 1
A D 14 I OUT
U in
0-10 V 7 D A
Mains voltage
A D 15 U OUT
I in
0-20 mA 8 D A 16 GND 2
NAMUR
Actuated: 1.2 mA
Not actuated: 2.1 mA
Control system
75 45
110
IN ,U,I,R OUT
MCR-PSP-DC
POWER
(+) 24 VDC 1 - 9 MM
POWER 0000
(-) GND 2 - 10 shield
IN
– For thermocouple sensors, resistance D 11 I (±)
12 3
thermometers, and linear resistors 11 4 μC 12 U (±)
– For current or voltage signals 13 GND (±)
14 5 A
– Four independently adjustable switching OUT 14 U (-)
22 6 15 U (+)
thresholds 21 7 E 16 I
– With or without electrical isolation of 24 8
input signals
– Programming via membrane keypad or
MCR-PICONF-WIN software Technical data
– Continuous measured value display Input data
Input sources Resistance thermometer 2, 3 or 4-conductor system (according to
DIN 43760/DIN IEC 751 or SAMA RC 21-4-1966), e.g., PT sensors,
Ni sensors, etc.
Further information about the configuration software can be found Thermocouple sensors (according to DIN IEC 584-1/DIN 43710):
on page 149 B, E, J, K, L, N, R, S, T, U
Resistance: 0 kΩ ... 8 kΩ (only 2-conductor connection)
1) EMC: Class A product, see page 571
Current: - 30 mA...+30 mA
Voltage: - 30 V...+30 V
Measuring rate 2 Hz
Input resistance Current / voltage 50 Ω / 200 kΩ
Discontinuous control resolution 0.1°C / 0.01 V / 0.01 mA / 0.1 Ω
Switching output
Contact type 2 x PDT contact, / 2 switching points each, pick-up/drop-out
(can be switched)
Contact material AgNi 0,15 + HTV (hard gold-plated)
Maximum switching voltage 250 V AC
Maximum switching current 2 A AC
Mechanical service life 2 x 107 cycles
Response delay 0 s ... 2 s (adjustable)
Status indication LED display
General data
Supply voltage UB 20 V DC ... 30 V DC
Current consumption < 60 mA
Maximum transmission error 0.1% (of final value)
Temperature coefficient ≤ 0.01%/K
Test voltage input/power supply 1 kV AC (50 Hz, 1 min.)
Ambient temperature (operation) -20°C ... 65°C
Status indication 5-position 7-segment display and LEDs
Mounting Any
Housing material ABS
Conformance / approvals
Conformance CE-compliant
UL, USA / Canada cULus
Pcs. /
Description Type Order No.
Pkt.
MCR threshold value switch, with two relay contacts
IN OUT
IN I/U 1 7 OUT A
GND 1 2 A B C 8 OUT B
0 IN
GND 1 3 9 OUT C
IN U,I 3x OUT
12 4 10 + 24VDC
11 5 11 GND 2 For either standard voltage or
POWER 14 6 12 GND 2 standard current signals
Housing width 17.5 mm
Technical data
Input data MCR-SWS-U1) MCR-SWS-I1)
Input signal 0 ... 10 V 0 ... 20 mA / 4 ... 20 mA
– 0 ... 10 V or 0 ... 20 mA input Maximum input signal 11 V 22 mA
– Relay/transistor output Input resistance ≥ 100 kΩ ≤ 120 Ω
Limit value setting Setting potentiometer, scaled 270° potentiometer
– Limit indicator Setting range of the limit value 0 V ... 10 V 0 A ... 20 mA
– Adjustable hysteresis Setting range for the hysteresis 0.1 V ... 10 V 0.2 mA ... 20 mA
(setting accuracy: ±30 mV) (setting accuracy: ±60 µA)
– Monitoring of three signal statuses
Internal hysteresis ±30 mV (around the lower/upper ±60 µA (around the lower/upper
Notes: switching point) switching point)
1) EMC: Class A product, see page 571
Switching output Transistor output, pnp
Number of outputs 3
Output voltage 20 V DC ... 30 V DC
Continuous load current 100 mA
Switching output Relay output
Contact type 1 PDT
Contact material AgNi 0,15 + HTV (hard gold-plated)
Maximum switching voltage 250 V AC (30 V DC)
Maximum switching current 2A
Mechanical service life 107 cycles
Error/status indicator
General data
Supply voltage UB 20 V DC ... 30 V DC
Current consumption Typ. 60 mA
Temperature coefficient ≤ 0.02%/K
Step response (10 - 90%) < 25 ms
Ambient temperature (operation) -20°C ... 65°C
Mounting Any
Housing material Polyamide PA non-reinforced
Dimensions W / H / D 17.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Conformance / approvals
Conformance CE-compliant
UL, USA / Canada UL 508 Recognized
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR threshold value switch, with adjustable hysteresis and
relay/transistor output
Input: 0..0.10 V MCR-SWS-U1) 2766465 1
Input: 0(4) - 20 mA MCR-SWS-I1) 2766478 1
Uref
IN OUT
U
10 V Sw 0V 0V
Housing width 30 mm
Technical data
Input data EMG 30-SP- 4K7LIN EMG 30-SP-10K LIN
Resistance value 4.7 kΩ ±20% 10 kΩ ±20%
– For direct setpoint definition in combina- Linearity 5% (of final value) 5% (of final value)
tion with a constant voltage source Load capacity 1W 0.5 W
Notes: General data
Ambient temperature (operation) 0°C ... 40°C
1) EMC: Class A product, see page 571 Mounting Any
Housing material Polycarbonate fiber reinforced PC-F
Dimensions W / H / D 30 / 75 / 68 mm
Screw connection solid / stranded / AWG 0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 14
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Setpoint potentiometer, to set setpoints individually
Accessories
MCR constant voltage source
With screw connection MINI MCR-SL-CVS-24-5-10-NC1) 2902822 1
With spring-cage connection MINI MCR-SL-CVS-24-5-10-SP-NC1) 2902823 1
Notes:
The software runs under the following operating systems:
Windows NT™, 2000™, and XP™.
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR configuration software, for programming MCR-T-...-,
MCR-...-LP-...-, MCR-...-HT-...-, MCR-S-...-, MCR-F-..., and
MCR-PSP-... modules, CD-ROM
MCR/PI-CONF-WIN 2814799 1
Accessories
Labels, for labeling MCR-T and MCR-S modules, four sheets MCR-ET 38X35 WH 2814317 1
DIN A4 marking labels (112 pieces.)
MCR-TTL-RS232-E 2814388 1
Software adapter cable (6-pos./D-SUB 25-pos.), 1.5 m length,
for programming MCR-PSP modules
MCR-TTL-RS232 2814391 1
Software adapter cable, 2.4 m length, with USB connection,
for programming MCR-...-LP-... and MCR-...-HT-... modules
MCR-PAC-T-USB 2309000 1
Accessories
Adapter cable, stranded, PSM-KAD 9 SUB 25/BS 2761295 1
9-pos. D-SUB socket on 25-pos. D-SUB pin
For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 149
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Special types of isolating amplifiers and digital displays
Analog IN
standard signals
10 VDC/30 mA 1 -
GND 1 2 -
GND 1 3 μC
LATCH 4
00000
IN U,I I 5 A
IN GND 2 6 D 0000
U 7 For standard analog signals, programmable
POWER
Housing width 48 mm
Technical data
Input data U input I input
Input signal 0 ... 10 V 0 ... 20 mA / 4 ... 20 mA
– For 0 ... 10 V and 0(4) ... 20 mA standard Maximum input signal 30 V DC 50 mA
analog signals Input resistance > 1 MΩ (approx. 100 Ω with 5 mA /
approx. 70 Ω with 20 mA)
– Programmable Resolution 1 mV 2 µA
– 5 positions displayed Measuring rate 0.5 to 2 measurements/second
Input latch signal Display stop
– 8 mm LED, 7-segment Switching level 1 signal (“H”) 4 V DC ... 30 V DC
– Galvanically isolated 0 signal (“L”) 0 V DC ... 2 V DC
– Min./max. value saving Output data
Display 7-segment LED; 8 mm; red
– Freely programmable decimal point Number of the displayed positions 5
display Accuracy < 0.1% ±1 digit (At an ambient temperature of 20°C)
– Latch/hold function for storing the display General data
value Supply voltage UB 10 V DC ... 30 V DC
– Display 48 x 24 mm Current consumption 50 mA
Data memory EEPROM 1 mil. memory cycles or 10 years
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR digital display, for measurement and display of
standard signals
MCR-SL-D-U-I 2864011 1
Accessories
MCR DIN rail adapter for digital displays in a 24 x 48 mm housing MCR-SL-D-RA 2810081 1
48
24
max. 19,3
59
+10...30 V 1 DC
GND 1 2 DC
HOLD 4
GND 2 3
Uref 7 0...12 V
0000 µC U OUT
Iref OUT 6 GND 3
D I OUT
IN 0000
With manual and automatic ramp function
A 5 0...24 mA
POWER
Housing width 48 mm
Technical data
Input data
Display 7-segment, 8 mm, red
– Manual setpoint definition with step Number of the displayed positions 4
width setting Switching level 1 signal (“H”) 4 V DC ... 30 V DC
0 signal (“L”) 0 V DC ... 2 V DC
– Manual setpoint definition via direct input Output data U output I output
– Automatic setpoint definition with hold Output signal 0 ... 12 V 0 ... 24 mA
Length of step 10 mV 10 µA
function and 20 support points Load RB ≥ 2 kΩ ≤ 500 Ω (Up to 20 mA)
– Highly adjustable 0 ... 12 V or 0 ... 24 mA ≤ 400 Ω (> 20 mA)
signal ranges Ripple ≤ 10 mVPP
General data
– Data backup in case of a power failure Supply voltage UB 10 V DC ... 30 V DC
– Display value parameterization Power consumption 1 W (With 24 mA/12 V)
Maximum transmission error < 0.2% ((full-scale) at rated voltage)
– Electrical isolation between output and Test voltage output/power supply 500 V AC (50 Hz, 1 min.)
supply Degree of protection IP65 from the front
Ambient temperature (operation) -20°C ... 65°C
Housing material Macrolon 2405
Dimensions W / H / D 48 / 24 / 68 mm
Control panel cutout 45(+0.6)x22.2(+0.3) mm
Screw connection solid / stranded / AWG 0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 26 - 16
Conformance / approvals
Conformance CE-compliant
UL, USA / Canada UL 508 Recognized
Ordering data
Pcs. /
Description Type Order No.
Pkt.
MCR digital setpoint encoder, for presetting current and
voltage signals
MCR-SL-D-SPA-UI 2710314 1
Accessories
MCR DIN rail adapter for digital displays in a 24 x 48 mm housing MCR-SL-D-RA 2810081 1
48
24
max.19,3
59
Highly compact – leading technology such as UL and GOST are available. Digital IN
MACX Analog Ex – single- and two-chan- NAMUR isolating amplifiers for the intrin-
nel signal isolating amplifiers for intrinsically Choose the right MACX Analog Ex sically safe operation of proximity sensors
safe circuits in the Ex area. isolating amplifier for your applica- and switches.
MACX Analog Ex isolating amplifiers en- tion: Digital OUT
sure maximum system safety and explosion
Analog IN Solenoid drivers for the intrinsically safe
protection within a minimum amount of
Measuring transducer repeater power operation of solenoid valves and alarm
space. With a design width of just 12.5 mm,
supply and input isolating amplifier for the transmitters.
this comprehensive range for analog signal
conditioning is approved according to ATEX intrinsically safe operation of 2-wire trans-
and IECEx and consistently SIL-certified. mitters, 4-conductor measuring transduc-
ers, and current sources.
Maximum explosion protection for all Analog OUT
Ex zones and gas groups Output isolating amplifiers for the intrin-
Many process technology systems have sically safe operation of control valves, I/P
areas where potentially explosive atmo- converters, and displays.
spheres may occur. As such, measuring and Temperature
control circuits are usually designed with in- Configurable temperature transducers
trinsic safety protection type Ex i. DIN rail connector-compatible
for the intrinsically safe operation of resis- The DIN rail connector enables the
MACX Analog Ex i isolating amplifiers and tance thermometers, remote resistance-
measuring transducers isolate intrinsically modular bridging of the 24 V supply
type sensors, thermocouples, and mV voltage.
safe circuits from non-intrinsically safe cir- sources – with safe limit value relays as an
cuits and safely limit the energy supplied to option.
the Ex area. Furthermore, they handle ex-
tensive signal conditioning tasks.
Wide-range power supply
All MACX Analog Ex isolating amplifiers
The modules featuring a wide-range
are approved in accordance with the appli-
power supply (...-UP) can be used in
cable ATEX and IECEx standards:
all power supply networks the
– [Ex ia] – for intrinsically safe circuits up to
world over without the need for ad-
Ex zone 0 and Ex zone 20
ditional power supply units.
– Ex n – for installing devices in Ex zone 2
– In addition, relevant national approvals
Significant space savings Easy-maintenance connection method: Flexible power bridging and diagnostics
– Housing width of just 12.5 mm for all sin- – Plug-in connection terminal blocks with – Supply voltage bridging and the option of
gle- and two-channel 24 V devices. Saves screw connection or fast push-in technol- redundant, diode-decoupled supply and
up to 45% of space, when compared to ogy – coded, with integrated sockets. error indication.
design widths up to 22.5 mm.
Easy configuration and monitoring Easy configuration Precise transmission, long service life
– Either via FDT/DTM or user-friendly – Without software via DIP switches on the – Patented circuit concepts ensure precise
stand-alone software – with integrated device front or with the operator inter- transmission and minimal self-heating.
monitoring function. face and display unit.
High operational reliability Safe and reliable functions Fast and error-free signal connection
– High operational reliability, thanks to safe – Consistent SIL certification. This ensures – Compact termination carriers connect
3-way electrical isolation. the highest level of reliability and safety MACX Analog Ex devices to the automa-
for your systems. tion system – plug and play.
Group I:
Electrical devices for firedamp areas
(mines) which are susceptible to pit gases
(methane) and/or combustible dusts (coal
dust).
Group II:
Electrical devices for operation in areas
where explosive gas atmospheres are likely
Simply dividing the various gases into ex- Potentially explosive areas are divided The ATEX Directive assigns devices for
plosion or gas groups according to their into zones according to the probability of use in potentially explosive areas to catego-
minimum ignition energy is not sufficient to their occurrence. The EN 60079-10-1 stan- ries. In IEC 60079-0, “Equipment Protection
describe the gases adequately with regard dard defines the zones containing explo- Level (EPL)” is the term used instead of
to their explosive properties. sive atmospheres as follows: “category”.
A gas may explode either when the igni- In the same way that there are different
tion energy is exceeded or where there is Zone 0: zones, there are also different device cate-
an excessively high temperature caused by a Area in which an explosive atmosphere is gories. These consist of categories M1 and
hot surface. This ignition temperature is, present for continuous or long periods. M2 for Group I and categories 1, 2, and 3 for
however, not usually linked to the ignition These conditions are usually present in- Group II. The categories for equipment
energy, i.e., a gas with a low ignition energy side containers, pipelines, apparatus, and group II are described in more detail be-
does not necessarily explode at a low tem- tanks. low:
perature. Consequently, devices that are Zone 1:
used directly in potentially explosive atmo- Area in which an explosive atmosphere is Category 1:
spheres are divided into temperature class- to be expected only occasionally during Devices constructed to guarantee a very
es. Temperature classes define the maxi- normal operation. high degree of safety.
mum surface temperature even in the event This includes the immediate area sur- Devices in this category must guarantee
of errors. Parallel to this, the gases are clas- rounding zone 0, as well as areas close to the required degree of safety even in the un-
sified according to their different ignition filling and emptying equipment. likely event of a device failure and therefore
temperatures. Zone 2: be provided with measures to protect
Temperature class Maximum permis- Ignition tempera-
Area in which an explosive atmosphere is against explosion, so that:
sible surface tures of combustible not expected during normal operation; – In the event of one integrated protection
temperature of substances
equipment however, if it does occur, then it does so measure failing, a second, independent
°C °C only rarely and for a short period. protection measure is able to guarantee
T1 450 > 450
Zone 2 includes areas that are used exclu- the necessary safety.
T2 300 > 300 450 sively for storage, areas around pipe con- – In the event of two independent errors,
T3 200 > 200 300 nections that can be disconnected, and gen- the necessary safety is guaranteed.
T4 135 > 135 200 erally the immediate area surrounding
T5 100 > 100 135
zone 1. Category 2:
T6 85 > 85 100
Devices constructed to guarantee a very
The following table provides an overview Areas that are potentially explosive as a high degree of safety.
of the ignition energies and ignition temper- result of combustible dusts are divided The explosion protection measures asso-
atures for certain gases: into the following zones according to EN ciated with this category guarantee the re-
Tempera- 60079-10-2 (formerly: EN 61241-10): quired degree of safety, even in the case of
Substance Tign ture Emin Group
class frequent device failures or common error
Ethoxyethane 170 T4 190 II B Zone 20: states.
Ethylene 425 T2 82 II B Area in which an explosive atmosphere is
Ammonia 630 T1 14000 II A present for continuous, frequent or long pe- Category 3:
Butane 365 T2 250 II A
Methane 595 T1 280 I
riods in the form of an airborne cloud of Devices constructed to guarantee a stan-
Propane 470 T1 250 II A combustible dust. dard degree of safety.
Carbon disulfide 95 T6 9 II C Zone 21: Devices in this category guarantee an ad-
Hydrogen 560 T1 16 II C Area in which an explosive atmosphere in equate degree of safety in normal opera-
the form of an airborne cloud of combusti- tion.
ble dust is to be expected only occasionally The table below shows which categories
during normal operation. are assigned to which zones:
Zone 22:
Category For Zone Also possible
Area in which an explosive atmosphere in
0 1 and 2
the form of an airborne cloud of combusti- 1 20 21 and 22
ble dust is not expected during normal op- 2 1 2
21 22
eration. However, if it does occur, then it
2
does so only for a short period. 3 22
Molded encapsulation m* Coils of relays and motors, electronics, solenoid valves, connection systems EN 60079-18
Exclusion Pressurized enclosure p Control cabinets, motors, measuring and analysis devices, computers EN 60079-2
Special mechanical design Flameproof enclosure d Motors, switching devices, power electronics EN 60079-1
Clearance from electrically Increased safety e Terminal blocks, housing, lights, motors EN 60079-7
conductive parts
nA: non-sparking
nC: sparking equipment Protection type “n” n** Motors, housing, lights, electronics EN 60079-15
nR: restricted breathing housing
nL: energy-limited
nP: simplified pressurized enclosures
* ia, ma: application in zone 0, 1, 2 / ib, mb: application in zone 1, 2 / ic, mc: application in zone 2 only ** Application in zone 2 only
0344
10 II (1) G [Ex ia Ga] IIC IBExU 08 ATEX 1069
Increased safety
0344
10 II 2 G Ex e IIC T6 Gb
Certificate number
Explosion-protected
mark does not apply to components.
solenoid valves, you have to have an intrin- details of the technical data of suitable
sically safe control circuit. This is provided valves, the maximum cable lengths, and the
by the solenoid drivers that are available maximum cable resistances of the individual
from Phoenix Contact. combinations) can be found on the Internet
The following must be taken into account at:
when dimensioning your intrinsically safe www.phoenixcontact.net/products PLC
control circuit:
– Valve
– Cable with corresponding resistance Intrinsically safe
equipment Associated equipment, e.g.,
– Solenoid driver II 1 G MAC MCR-EX-SL-SD-...
Ex ia IIB T6 II (1) GD [Ex ia] IIC
As a result, it may be the case that not all
valves are compatible with the solenoid
drivers.
Safety integrity level: failure limit values for a safety function which is op-
erated in an operating mode with a low demand rate.
+ +
4.1 4.1 3.1 3.1
2.2
-
2.1
5.2 - 5.2 2.1
active
250 W
+
POWER 5.1
+
5.1 GND 3.2
I I OUT 1.2
IN +24V -
Repeater power supply and
1.1 2.2
Power
POWER input isolating amplifier
GND +24V +
Zone 0,1,2 2.1
Zone 20,21,22
Div. 1,2
Zone 2
Div. 2
Functional safety
Ex: // Applied for: GL
Housing width 12.5 mm
Technical data
Input data
Input signal 0 mA ... 20 mA / 4 mA ... 20 mA
Repeater power supply and input isolating Transmitter supply voltage > 16 V (at 20 mA)
amplifier for the operation of intrinsically Voltage drop < 3.5 V (in input isolating amplifier operation)
Output data
safe (Ex-i) 2-conductor measuring transduc- Output signal 0 mA ... 20 mA (active)
ers, 4-conductor measuring transducers, 4 mA ... 20 mA (active)
0 mA ... 20 mA (14 ... 26 V ext. source voltage)
and mA current sources installed in Ex ar- 4 mA ... 20 mA (14 ... 26 V ext. source voltage)
eas. Load < 600 Ω
Output ripple < 20 mVrms
General data
– 0/4 ... 20 mA input, [Ex ia] Supply voltage range 19.2 V DC ... 30 V DC
(powered or not powered) Current consumption < 60 mA (at 24 V DC)
Power dissipation < 1.1 W (at 24 V DC / 20 mA)
– 0/4...20 mA output (active or passive) Temperature coefficient < 0.01%/K
– Bidirectional transmission of digital HART Step response (10 - 90%) < 600 µs (for 4 mA ... 20 mA step)
Transmission error, typical < 0.05% (of final value)
communication signals Maximum transmission error < 0.1% (of final value)
– Plug-in capable screw or spring-cage con- Under-/overload range as per NE 43
nection method, with integrated sockets Electrical isolation
Input/output/power supply 2.5 kV (50 Hz, 1 min., test voltage)
for HART communicators 300 Vrms (Rated insulation voltage,
– Terminal point with 250 Ω resistor to in- surge voltage category II; pollution degree 2,
safe isolation as per EN 61010, EN 50178)
crease the HART impedance in the case
of low-impedance systems Input/output 375 V (Peak value in accordance with EN 60079-11)
Input/power supply 375 V (Peak value in accordance with EN 60079-11)
– 3-way electrical isolation Ambient temperature range -20°C ... 60°C (Any mounting position)
– Power supply via DIN rail connector Humidity 10% ... 95% (no condensation)
possible Status indication Green LED (supply voltage)
SMART communication Yes
– Up to SIL 2 according to EN 61508 Signal bandwidth as per HART specifications
– Installation in zone 2 permitted Protocols supported HART
Housing material PA 66-FR
Notes: Inflammability class according to UL 94 V0
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Information about the supply and error evaluation module as well
as about the DIN rail connectors and marking material can be Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
found from page 182 Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Safety data as per ATEX
Test plugs for test sockets can be found on page 191
Maximum voltage Uo 25.2 V
Information on “Plug and play” connection using system cabling Maximum current Io 93 mA
can be found from page 184 Maximum power Po 587 mW
1) EMC: Class A product, see page 571 Maximum voltage Um 253 V AC (125 V DC)
Conformance / approvals
Conformance CE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC/IIB
II (1) D [Ex ia Da] IIIC
II 3(1) G Ex nA [ia Ga] IIC/IIB T4 Gc
IECEx [Ex ia Ga] IIC/IIB; [Ex ia Da] IIIC; Ex nA [ia Ga] IIC/IIB T4 Gc
UL, USA / Canada Class I Div 2; IS for Class I, II, III Div 1
Functional safety (SIL) SIL 2 according to EN 61508
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Repeater power supply, smart, intrinsically safe input
OUT1 2.2
passive
OUT 2 -
2.2
I 5.2 - 5.2 2.1
+
POWER OUT2 5.1
+
5.1 GND 2.1
I I 1.2
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Repeater power supply, smart, intrinsically safe input
passive
5.2 - 5.2
-
2.2 2.2
POWER CH2 active CH2
I I OUT + +
IN 5.1 5.1 2.1 2.1
HHT
POWER I I OUT GND HHT
1.2
IN 2-channel repeater power supply
+24V
1.1
Power
POWER
GND +24V
Zone 0,1,2
Zone 20,21,22 Zone 2
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Repeater power supply, 2-channel, smart, intrinsically safe input
250 W
active
- 4.3
-
3.3
POWER +
4.2
I I OUT 24...230 V –
1.2
IN ~ +
AC/DC 3.2 Repeater power supply and
1.1
DIP switches to increase the HART im- Input/output 375 V (Peak value in accordance with EN 60079-11)
pedance in the case of low-impedance Input/power supply 375 V (Peak value in accordance with EN 60079-11)
Ambient temperature range -20°C ... 60°C (Any mounting position)
systems Humidity 10% ... 95% (no condensation)
– 3-way electrical isolation Status indication Green LED (supply voltage)
– Wide-range power supply: SMART communication Yes
Signal bandwidth as per HART specifications
19.2 ... 253 V AC/DC Protocols supported HART
– Up to SIL 2 according to EN 61508 Housing material PA 66-FR
Inflammability class according to UL 94 V0
– Installation in zone 2 permitted Dimensions W / H / D 17.5 / 99 / 114.5 mm
Notes: Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Information on marking material can be found on page 127 Safety data as per ATEX
Test plugs for test sockets can be found on page 191 Maximum voltage Uo 25.2 V
Maximum current Io 93 mA
1) EMC: Class A product, see page 571
Maximum power Po 587 mW
Maximum voltage Um 253 V AC (125 V DC)
Conformance / approvals
Conformance CE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC/IIB
II (1) D [Ex ia Da] IIIC
II 3(1) G Ex nA [ia Ga] IIC/IIB T4 Gc
IECEx [Ex ia Ga] IIC/IIB; [Ex ia Da] IIIC; Ex nA [ia Ga] IIC/IIB T4 Gc
UL, USA / Canada Class I Div 2; IS for Class I, II, III Div 1
Functional safety (SIL) SIL 2 according to EN 61508
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Repeater power supply, smart, intrinsically safe input
AO
- -
4.2 - 4.2 3.2 3.2
P
+ + +
4.1 4.1 3.1 3.1
-
4.2
+
4.1
I I
OUT IN -
GND
1.2
4.2
+ +24V
4.1 1.1
POWER Power
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Output isolating amplifier, smart, output intrinsically safe
-
4.2 4.2 3.2 3.2
ϑ ϑ ϑ
μC μC passive
+
4.1 4.1 3.1 3.1
5.2 5.2
5.1 5.1
IN I OUT GND
1.2
+24V
1.1 For resistance thermometers and
Power
POWER resistance-type sensors
GND +24V
Zone 0,1,2
Zone 20,21,22
Div. 1,2
Zone 2
Div. 2
Ex:
Housing width 12.5 mm
Technical data
Input data
Resistance thermometers Pt, Ni, Cu sensors: 2, 3, 4-conductor
Programmable temperature transducer Resistor 0 Ω ... 2000 Ω
for intrinsically safe operation of resistance Cable resistance 50 Ω per line
Sensor input current (200 μA ... 1 mA)
thermometers and resistance-type sensors Measuring range span min. 50 K
installed in Ex areas. The measured values Output data
Output signal 0 mA ... 20 mA / 4 mA ... 20 mA
are converted into a linear 0 ... 20 mA or Load max. 500 Ω
4 ... 20 mA signal. Behavior in the event of a sensor error As per NE 43 or can be freely defined
Output ripple < 50 µAPP
General data
– Input for resistance thermometers and Supply voltage range 19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%))
resistance-type sensors, [Ex ia] Current consumption < 40 mA (24 V DC)
– 0 ... 20 mA or 4 ... 20 mA output Power dissipation <1W
Temperature coefficient 0.01%/K
– Configuration via software (FDT/DTM): Step response (0 - 99%) Typ. 800 ms (With SIL)
Sensor type, connection method, mea- max. 1200 ms (With SIL)
Typ. 700 ms (Without SIL)
suring range, measuring unit, filter, alarm max. 1100 ms (Without SIL)
signal, and output range Transmission error, total 0.05% x 100 [K] / measuring range span [K] + 0.05%
ZERO / SPAN adjustment ±5% / ±5%
– Programming during operation with Ex Electrical isolation
measuring circuit connected and also volt- Input/output/power supply 2.5 kV (50 Hz, 1 min., test voltage)
300 Vrms (Rated insulation voltage,
age-free using IFS-USB-PROG-ADAPTER surge voltage category II; pollution degree 2,
programming adapter safe isolation as per EN 61010, EN 50178)
Input/output 375 V (Peak value in accordance with EN 60079-11)
– Status indicator for supply voltage, cable, Input/power supply 375 V (Peak value in accordance with EN 60079-11)
sensor, and module errors Ambient temperature range -20°C ... 60°C (Any mounting position)
– 3-way electrical isolation Humidity 5% ... 95% (no condensation)
Status indication Green LED (supply voltage, PWR)
– Power supply via DIN rail connector Red LED, flashing (line, sensor error, ERR)
possible Red LED (module error, ERR)
Housing material PA 66-FR
– Up to SIL 2 according to EN 61508 Inflammability class according to UL 94 V0
– Installation in zone 2 permitted Dimensions W / H / D 12.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Notes: Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
To order a product with an order configuration, please enter the Safety data as per ATEX
desired configuration by referring to the order key, see page 167 Maximum voltage Uo 6V
Maximum current Io 6.3 mA
The configuration software can be downloaded from the Internet
Maximum power Po 9.4 mW
(www.phoenixcontact.net/products).
Conformance / approvals
Information about the supply and error evaluation module as well Conformance CE-compliant, additionally EN 61326
as about the DIN rail connectors and marking material can be ATEX II (1) G [Ex ia Ga] IIC
found from page 182 II (1) D [Ex ia Da] IIIC
For information on the programming adapter, refer to page 119 II 3(1) G Ex nA ic [ia Ga] IIC T4 Gc X
IECEx [Ex ia Ga] IIC; [Ex ia Da] IIIC; Ex nA ic [ia Ga] IIC T4 Gc
Information on “Plug and play” connection using system cabling
UL, USA / Canada Class I Div 2; IS for Class I, II, III Div 1
can be found from page 184
Functional safety (SIL) SIL 2 TÜV Rheinland 968/EZ374.00/09
1) EMC: Class A product, see page 571
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Temperature measuring transducers for
resistance thermometers, intrinsically safe input
Order configuration Screw connection MACX MCR-EX-SL-RTD-I1) 2865939 1
Order configuration Spring-cage conn. MACX MCR-EX-SL-RTD-I-SP1) 2924142 1
Standard configuration Screw connection MACX MCR-EX-SL-RTD-I-NC1) 2865573 1
Standard configuration Spring-cage conn. MACX MCR-EX-SL-RTD-I-SP-NC1) 2924168 1
Accessories
Programming adapter for configuring modules with IFS-USB-PROG-ADAPTER1) 2811271 1
S-PORT interface
For additional information, visit www.phoenixcontact.net/products PHOENIX CONTACT 165
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Measurement and control technology
Ex i isolating amplifiers with SIL functional safety - MACX Analog Ex
Temperature transducer, Ex i
-
4.2 4.2 3.2 3.2
-
μC μC passive
+ +
4.1 4.1 3.1 3.1
IN I OUT GND
1.2
+24V
1.1 For thermocouples and mV sources
Power
POWER
GND +24V
Zone 0,1,2
Zone 20,21,22
Div. 1,2
Zone 2
Div. 2
Ex:
Housing width 12.5 mm
Technical data
Input data
Thermocouple sensors E, J, K, N as per IEC / EN 60584, L as per DIN 43760
Programmable temperature transducer
Voltage -20 mV ... 70 mV
for intrinsically safe operation of thermo- Measuring range span (Min. 50 K for thermocouples, 3 mV for mV sources)
couples and mV sources installed in Ex ar-
eas. The measured values are converted Output data
Output signal 0 mA ... 20 mA / 4 mA ... 20 mA
into a linear 0 ... 20 mA or 4 ... 20 mA signal. Load max. 500 Ω
Behavior in the event of a sensor error As per NE 43 or can be freely defined
Output ripple < 50 µAPP
– Input for thermocouples and mV sources, General data
[Ex ia] Supply voltage range 19.2 V DC ... 30 V DC
– 0 ... 20 mA or 4 ... 20 mA output Current consumption < 40 mA (24 V DC)
Power dissipation <1W
– Configuration via software (FDT/DTM): Temperature coefficient 0.01%/K
Sensor type, connection method, mea- Step response (0 - 99%) Typ. 800 ms (With SIL)
max. 1200 ms (With SIL)
suring range, measuring unit, filter, alarm Typ. 700 ms (Without SIL)
signal, and output range max. 1100 ms (Without SIL)
Transmission error, total 0.05% x 200 [K]/Measuring range span [K] + 0.05%
– Programming during operation with Ex Cold junction errors ±1 K
measuring circuit connected and also volt- ZERO / SPAN adjustment ±5% / ±5%
age-free using IFS-USB-PROG-ADAPTER Electrical isolation
Input/output/power supply 2.5 kV (50 Hz, 1 min., test voltage)
programming adapter 300 Vrms (Rated insulation voltage,
– Status indicator for supply voltage, cable, surge voltage category II; pollution degree 2,
safe isolation as per EN 61010, EN 50178)
sensor, and module errors
– 3-way electrical isolation Input/output 375 V (Peak value in accordance with EN 60079-11)
Input/power supply 375 V (Peak value in accordance with EN 60079-11)
– Power supply via DIN rail connector Ambient temperature range -20°C ... 60°C (Any mounting position)
possible Humidity 5% ... 95% (no condensation)
– Up to SIL 2 according to EN 61508 Status indication Green LED (supply voltage, PWR)
Red LED, flashing (line, sensor error, ERR)
– Installation in zone 2 permitted Red LED (module error, ERR)
Housing material PA 66-FR
Notes: Inflammability class according to UL 94 V0
To order a product with an order configuration, please enter the Dimensions W / H / D 12.5 / 99 / 114.5 mm
desired configuration by referring to the order key, see page 167 Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Safety data as per ATEX
The configuration software can be downloaded from the Internet
Maximum voltage Uo 6V
(www.phoenixcontact.net/products).
Maximum current Io 4.7 mA
Information about the supply and error evaluation module as well Maximum power Po 7 mW
as about the DIN rail connectors and marking material can be Maximum voltage Um 253 V AC (125 V DC)
found from page 182
Conformance / approvals
For information on the programming adapter, refer to page 119 Conformance CE-compliant, additionally EN 61326
Information on “Plug and play” connection using system cabling ATEX II (1) G [Ex ia Ga] IIC
can be found from page 184 II (1) D [Ex ia Da] IIIC
II 3(1) G Ex nA ic [ia Ga] IIC T4 Gc X
1) EMC: Class A product, see page 571 IECEx [Ex ia Ga] IIC; [Ex ia Da] IIIC; Ex nA ic [ia Ga] IIC T4 Gc
UL, USA / Canada Class I Div 2; IS for Class I, II, III Div 1
Functional safety (SIL) SIL 2 TÜV Rheinland 968/EZ374.00/09
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Temperature measuring transducers for thermocouples,
intrinsically safe input
Order configuration Screw connection MACX MCR-EX-SL-TC-I1) 2865942 1
Standard configuration Screw connection MACX MCR-EX-SL-TC-I-NC1) 2865586 1
Accessories
Programming adapter for configuring modules with IFS-USB-PROG-ADAPTER1) 2811271 1
S-PORT interface
Order key for MACX-MCR-EX-SL-RTD-I(-SP) temperature transducer (standard configuration entered as an example)
Order No. Sensor type Safety integrity level Connection Measuring range: Measuring Output range Filter Filter
(SIL) technology Start End unit Oversampling Moving average value
2865939 = see below ON = active 2 = 2-conductor see be- see be- C = °C OUT01 = 0...20 mA 1 = 1 value 1 = 1 value
MACX MCR-EX- NONE = not active low low F = °F 3 = 3 values 2 = 2 values
SL-RTD-I 3 = 3-conductor O = OUT02 = 4...20 mA 5 = 5 values 3 = 3 values
ON only with output range 7 = 7 values 4 = 4 values
2924142 = = OUT02 4 = 4-conductor 10 = 10 values
MACX MCR-EX- 20 = 20 values
SL-RTD-I-SP Smallest measuring
range span
RES01 = Resistor 0 2000 25
PT50 = Pt 50 acc. to IEC 751 -200 850 °C 50 K
PT100 = Pt 100 acc. to IEC 751 -200 850 °C 50 K
PT200 = Pt 200 acc. to IEC 751 -200 850 °C 50 K
PT500 = Pt 500 acc. to IEC 751 -200 850 °C 50 K
PT100S = Pt 100 acc. to Sama RC21-4-1966 -200 600 °C 50 K
PT500S = Pt 500 acc. to Sama RC21-4-1966 -200 600 °C 50 K
NI100DIN = Ni 100 acc. to DIN 43760 -60 250 °C 50 K
NI500DIN = Ni 500 acc. to DIN 43760 -60 250 °C 50 K
CU50 = CU50 acc. to GOST 6651 ( = 1.428) -50 200 °C 50 K
CU53 = CU53 acc. to GOST 6651 ( = 1.426) -50 180 °C 50 K
Order key for MACX-MCR-EX-SL-TC-I temperature transducer (standard configuration entered as an example)
Order No. Sensor type Safety integrity level Cold junction com- Measuring range: Measuring Output range Filter Filter
(SIL) pensation Start End unit Oversampling Moving average value
MACX MCR-EX- see below ON = active 1 = switched on see be- see be- C = °C OUT01 = 0...20 mA 1 = 1 value 1 = 1 value
SL-TC-I NONE = not active low low F = °F 3 = 3 values 2 = 2 values
0 = switched off V = mV OUT02 = 4...20 mA 5 = 5 values 3 = 3 values
(e.g., for mV volt- 7 = 7 values 4 = 4 values
age measure- 10 = 10 values
ON only with output range ment) 20 = 20 values
= OUT02
Smallest measuring
range span
V03 = Voltage (mV) -20 +70 mV 3 mV
E = acc. to IEC 584-1 (NiCr-CuNi) -250 1000 °C 50 K
J = acc. to IEC 584-1 (Fe-CuNi) -210 1200 °C 50 K
K = acc. to IEC 584-1 (NiCr-Ni) -250 1372 °C 50 K
N = acc. to IEC 584-1 (NiCrSi-NiSi) -250 1300 °C 50 K
L = acc. to DIN 43760 (Fe-CuNi) -200 900 °C 50 K
passive
RTD
-
4.3 4.3 GND 3.3 3.3 3.3 -
S-PORT
TC ϑ
+
- 4.2 4.2 I OUT 3.2 3.2
ϑ +
+ 4.1 4.1 U OUT 3.1 3.1
μC
Poti
4.3 2.3 2.3 14
ϑ
4.2 2.2 2.2 11 DI
U,I 4.1 2.1 2.1 12
5.1 5.1
24V ...230V AC/DC
1.1
Universal, with switching output,
POWER wide-range power supply
Zone 0,1,2
Zone 20,21,22 Zone 2
Functional safety
Ex:
Housing width 17.5 mm
Technical data
Input data
Resistance thermometers Pt, Ni, Cu sensors: 2, 3, 4-conductor
Universal temperature transducer with Thermocouple sensors B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
freely configurable properties for intrinsical- Resistor 0 Ω ... 50 kΩ
ly safe operation of resistance thermome- Potentiometer 0 Ω ... 50 kΩ
ters, thermocouples, resistance-type Voltage -1000 mV ... 1000 mV
Output data U output I output
sensors, and potentiometers installed in Output signal 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
Ex areas
Maximum output signal ±11 V 22 mA
Load RB ≥ 10 kΩ ≤ 600 Ω (20 mA)
– Input for resistance thermometers, ther- Behavior in the event of a sensor error According to NE 43 or freely configurable
mocouples, resistance-type sensors, po- Switching output Switching output
Contact type 1 PDT
tentiometers, and mV sources, [Ex ia] Contact material AgSnO2, hard gold-plated
– Measure differential temperatures Maximum switching voltage 30 V AC (30 V DC)
– Freely programmable input and output Maximum switching current 0.5 A (30 V AC) / 1 A (30 V DC)
General data
– Option of inverse output signal ranges Supply voltage range 24 V ... 230 V AC/DC (-20%/+10%, 50/60 Hz)
– Relay switching output Power consumption < 1.5 W
Temperature coefficient 0.01%/K
– Configuration via software (FDT-DTM) or Transmission error, total < 0.1% (e.g., for Pt 100, 300 K span, 4 ... 20 mA)
IFS-OP-UNIT operating and display unit Electrical isolation
– Programming during operation with Input/output/power supply 2.5 kV (50 Hz, 1 min., test voltage)
Input/output 375 V (Peak value in accordance with EN 60079-11)
Ex measuring circuit connected and also Input/power supply 375 V (Peak value in accordance with EN 60079-11)
voltage-free using IFS-USB-PROG- Input/switching output 375 V (Peak value in accordance with EN 60079-11)
ADAPTER programming adapter Output/power supply 300 Vrms (Rated insulation voltage,
surge voltage category II; pollution degree 2,
– Plug-in capable screw or spring-cage con- safe isolation as per EN 61010, EN 50178)
nection method Ambient temperature range -20°C ... 65°C
– Cold junction compensation with sepa- Humidity Typ. 5% ... 95% (no condensation)
rate connector Housing material PA 66-FR
Inflammability class according to UL 94 V0
– Wide-range power supply: Dimensions W / H / D 17.5 / 99 / 114.5 mm
19.2 ... 253 V AC/DC Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
– Status indicator for supply voltage, cable, Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Safety data as per ATEX
sensor, and module errors Maximum voltage Uo 6V
– Up to SIL 2 according to EN 61508 Maximum current Io 7.4 mA
Maximum power Po 11 mW
– Installation in zone 2 permitted Conformance / approvals
Conformance CE-compliant
Notes:
ATEX II (1) G [Ex ia Ga] IIC
To order a product with an order configuration, enter the required II (1) D [Ex ia Da] IIIC
configuration by referring to the adjacent order key. II 3 G Ex nA nC ic IIC T4 Gc X
The configuration software can be downloaded from the Internet IECEx [Ex ia Ga] IIC; [Ex ia Da] IIIC; Ex nA nC ic IIC T4 Gc
(www.phoenixcontact.net/products). Functional safety (SIL) SIL 2, PL d
Information on the IFS-OP-UNIT operating and display unit and the Ordering data
associated IFS-OP-CRADLE DIN rail cradle can be found on
page 118 Pcs. /
Description Type Order No.
For information on the programming adapter, refer to page 119 Pkt.
1) EMC: Class A product, see page 571 Temperature transducer, intrinsically safe input
Accessories
Programming adapter for configuring modules with IFS-USB-PROG-ADAPTER1) 2811271 1
S-PORT interface
Order No. Safety integrity level Sensor type Connection Cold junction Measuring range: Measuring Output range Factory calibration
(SIL) technology compensation Start End unit certificate = FCC
2811763 = ON = active see below 2 = 2-conductor 0 = off, e.g., with see be- see be- C = °C OUT15 = 0...5 mA NONE = without FCC
MACX MCR-EX- RTD, R, potenti- low low F = °F OUT16 = 0...10 mA
T-UI-UP-C NONE = not active ometer, mV O = OUT01 = 0...20 mA
3 = 3-conductor P = % OUT15 = 0...5 mA YES = with FCC (a fee is
2924692 = V = mV OUT25 = 1...5 mA charged)
MACX MCR-EX- ON only with output 1 = on, e.g., with TC OUT26 = 2...10 mA
T-UI-UP-SP-C range = OUT02 4 = 4-conductor OUT02 = 4...20 mA
OUT05 = 0...5 V YESPLUS = FCC with
OUT03 = 0...10 V 5 measuring points
OUT06 = 1...5 V (a fee is charged)
OUT04 = 2...10 V
OUT13 = -5...+5 V
OUT14 = -10...+10 V
Others can be freely
configured in the soft-
ware
Resistance thermometers (RTD) PT100 = Pt 100 acc. to IEC 751 -200 850 °C 20 K - Freely configurable user characteristic curve
Others can be selected or freely config- PT200 = Pt 200 acc. to IEC 751 -200 850 °C 20 K with 30 interpolation points
ured in the software. PT500 = Pt 500 acc. to IEC 751 -200 850 °C 20 K
PT1000 = Pt 1000 acc. to IEC 751 -200 850 °C 20 K - Output behavior in the event of a short circuit,
PT100S = Pt 100 acc. to Sama RC21-4-1966 -200 850 °C 20 K sensor break or overrange/underrange can be
freely configured or set according to NE43
PT1000S = Pt 1000 acc. to Sama RC21-4-1966 -200 850 °C 20 K
(standard configuration: NE43 upscale)
PT100G = Pt 100 acc. to GOST 6651-2009 ( = 0.00385) -200 850 °C 20 K
PT1000G = Pt 1000 acc. to GOST 6651-2009 ( = 0.00385) -200 850 °C 20 K - Filter setting (standard configuration: 1)
PT100J = Pt 100 acc. to JIS C1604/1997 -200 850 °C 20 K
PT1000J = Pt 1000 acc. to JIS C1604/1997 -200 850 °C 20 K - Restart after failsafe (standard configuration:
NI100 = Ni 100 acc. to DIN 43760/DIN IEC 60751 -60 250 °C 20 K ON)
NI1000 = Ni 1000 acc. to DIN 43760/DIN IEC 60751 -60 250 °C 20 K
NI100S = Ni 100 acc. to Sama RC21-4-1966 -60 180 °C 20 K - Switching behavior: switching output ?
NI1000S = Ni 1000 acc. to Sama RC21-4-1966 -60 180 °C 20 K (limit values, times, etc.) (standard configura-
NI1000L = Ni 1000 (Landis & Gyr) -50 160 °C 20 K tion: OFF)
CU10 = Cu 10 acc. to Sama RC21-4-1966 -70 500 °C 100 K
CU50 = Cu 50 acc. to GOST 6651-2009 ( = 0.00428) -50 200 °C 100 K
CU100 = Cu 100 acc. to GOST 6651-20091 ( = 0.00428) -50 200 °C 100 K
CU53 = Cu 53 acc. to GOST 6651-2009 ( = 0.00426) -50 180 °C 100 K
KTY81 = KTY81-110 (Philips) -55 150 °C 20 K
KTY84 = KTY84-130 (Philips) -40 300 °C 20 K
Voltage signals (mV) V04 = Voltage (mV) -1000 +1000 mV 10% of nominal
Others can be selected in the software. span
9
Temperature conversion guide for °C to °F: T [°F] = – T [°C] + 32
5
passive
RTD -
3.3 3.3 -
TC ϑ
4.3 4.3 GND 3.3
+
+ 3.2
- 4.2 4.2 I OUT 3.2
ϑ 3.1
+ 4.1 4.1 U OUT 3.1
Poti 3x 3.6 34
4.3
ϑ
3.5 31 DI
4.2
3.4 32
U,I 4.1
2.6 24
5.3 5.3 NC 1.3
IN OUT 2.5 21 DI
5.2 5.2 Power 1.2
3x 5.1 5.1
24V ...230V AC/DC
1.1
2.4 22 Universal, with three limit value relays,
POWER wide-range power supply
1.6 14
For information on the programming adapter, refer to page 119 Temperature transducer, intrinsically safe input
1) EMC: Class A product, see page 571
Standard configuration Screw connection MACX MCR-EX-T-UIREL-UP1) 2865751 1
Standard configuration Spring-cage conn. MACX MCR-EX-T-UIREL-UP-SP1) 2924799 1
Order configuration Screw connection MACX MCR-EX-T-UIREL-UP-C1) 2865722 1
Order configuration Spring-cage conn. MACX MCR-EX-T-UIREL-UP-SP-C1) 2924809 1
Accessories
Programming adapter for configuring modules with S-PORT IFS-USB-PROG-ADAPTER1) 2811271 1
interface
Order No. Safety integrity level Sensor type Connection Cold junction Measuring range: Measuring Output range Factory calibration
(SIL) technology compensation Start End unit certificate = FCC
2865722 = ON = active see below 2 = 2-conductor 0 = off, e.g., with see be- see be- C = °C OUT15 = 0...5 mA NONE = without FCC
MACX MCR-EX- RTD, R, potenti- low low F = °F OUT16 = 0...10 mA
T-UIREL-UP-C NONE = not active ometer, mV O = OUT01 = 0...20 mA
3 = 3-conductor P = % OUT15 = 0...5 mA YES = with FCC (a fee is
2924809 = V = mV OUT25 = 1...5 mA charged)
MACX MCR-EX- ON only with output 1 = on, e.g., with TC OUT26 = 2...10 mA
T-UIREL-UP-SP-C range = OUT02 4 = 4-conductor OUT02 = 4...20 mA
OUT05 = 0...5 V YESPLUS = FCC with
OUT03 = 0...10 V 5 measuring points
OUT06 = 1...5 V (a fee is charged)
OUT04 = 2...10 V
OUT13 = -5...+5 V
OUT14 = -10...+10 V
Others can be freely
configured in the soft-
ware
Resistance thermometers (RTD) PT100 = Pt 100 acc. to IEC 751 -200 850 °C 20 K - Freely configurable user characteristic curve
Others can be selected or freely config- PT200 = Pt 200 acc. to IEC 751 -200 850 °C 20 K with 30 interpolation points
ured in the software. PT500 = Pt 500 acc. to IEC 751 -200 850 °C 20 K
PT1000 = Pt 1000 acc. to IEC 751 -200 850 °C 20 K - Output behavior in the event of a short circuit,
PT100S = Pt 100 acc. to Sama RC21-4-1966 -200 850 °C 20 K sensor break or overrange/underrange can be
freely configured or set according to NE43
PT1000S = Pt 1000 acc. to Sama RC21-4-1966 -200 850 °C 20 K
(standard configuration: NE43 upscale)
PT100G = Pt 100 acc. to GOST 6651-2009 ( = 0.00385) -200 850 °C 20 K
PT1000G = Pt 1000 acc. to GOST 6651-2009 ( = 0.00385) -200 850 °C 20 K - Filter setting (standard configuration: 1)
PT100J = Pt 100 acc. to JIS C1604/1997 -200 850 °C 20 K
PT1000J = Pt 1000 acc. to JIS C1604/1997 -200 850 °C 20 K - Restart after failsafe (standard configuration:
NI100 = Ni 100 acc. to DIN 43760/DIN IEC 60751 -60 250 °C 20 K ON)
NI1000 = Ni 1000 acc. to DIN 43760/DIN IEC 60751 -60 250 °C 20 K
NI100S = Ni 100 acc. to Sama RC21-4-1966 -60 180 °C 20 K - Switching behavior: switching output ?
NI1000S = Ni 1000 acc. to Sama RC21-4-1966 -60 180 °C 20 K (limit values, times, etc.) (standard configura-
NI1000L = Ni 1000 (Landis & Gyr) -50 160 °C 20 K tion: OFF)
CU10 = Cu 10 acc. to Sama RC21-4-1966 -70 500 °C 100 K
CU50 = Cu 50 acc. to GOST 6651-2009 ( = 0.00428) -50 200 °C 100 K
CU100 = Cu 100 acc. to GOST 6651-2009 ( = 0.00428) -50 200 °C 100 K
CU53 = Cu 53 acc. to GOST 6651-2009 ( = 0.00426) -50 180 °C 100 K
KTY81 = KTY81-110 (Philips) -55 150 °C 20 K
KTY84 = KTY84-130 (Philips) -40 300 °C 20 K
Voltage signals (mV) V04 = Voltage (mV) -1000 +1000 mV 10% of nominal
Others can be selected in the software. span
9
Temperature conversion guide for °C to °F: T [°F] = – T [°C] + 32
5
-
4.2 12
2.2 2.2
+
4.1
Faultsignal
IN OUT GND
1.2
4.2 +24V
1.1 Signal output: PDT relay
4.1 Power
POWER
LFD +24V
Zone 0,1,2 GND
Zone 20,21,22
Div. 1,2
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolating amplifier for intrinsical- Floating switch contacts
Switch contacts with resistance circuit
ly safe operation of proximity sensors and No-load voltage 8 V DC ±10%
mechanical contacts installed in Ex areas. Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
Switching hysteresis < 0.2 mA
Line error detection Break 0.05 mA < IIN < 0.35 mA
– Input for NAMUR proximity sensors Short-circuit 100 Ω < RSensor < 360 Ω
(EN 60947-5-6), floating contacts or Switching output Relay output
Contact type 1 PDT
contacts with resistance circuit, [Ex ia] Contact material AgSnO2, hard gold-plated
– Relay signal output (PDT) Maximum switching voltage 250 V AC (2 A) / 120 V DC (0.2 A) / 30 V DC (2 A)
– Reversible direction of action (operating Maximum switching capacity 500 VA
Recommended minimum load 5 V / 10 mA
current or closed-circuit current behav- Mechanical service life 107 cycles
ior) Switching behavior Can be inverted via slide switch
Maximum switching frequency 20 Hz (without load)
– Line fault detection (LFD), can be activat- General data
ed/deactivated, error message signaled by Supply voltage range 19.2 V DC ... 30 V DC
red flashing LED with de-excitation of Current consumption 21 mA (24 V DC)
Power dissipation < 650 mW
output relay Number of channels 1
– Power supply and error indication possi- Electrical isolation
ble via the DIN rail connector Input/output 375 V (Peak value in accordance with EN 60079-11)
Input/power supply 375 V (Peak value in accordance with EN 60079-11)
– LED displays for indicating supply voltage, Input/output/supply, T-Connector 300 Vrms (Rated insulation voltage,
circuit state, and malfunctions to surge voltage category II; pollution degree 2,
basic insulation as per EN 61010, EN 50178)
NAMUR NE 44 2.5 kV (50 Hz, 1 min., test voltage)
– 3-way electrical isolation
Ambient temperature range -20°C ... 60°C (Any mounting position)
– Up to SIL 2 according to EN 61508 Humidity 10% ... 95% (no condensation)
– Installation in zone 2 permitted Status indication Green LED (supply voltage)
LED yellow (switching state)
Notes: Red LED (line errors)
Housing material PA 66-FR
Information about the supply and error evaluation module as well Inflammability class according to UL 94 V0
as about the DIN rail connectors and marking material can be
Dimensions W / H / D 12.5 / 99 / 114.5 mm
found from page 182
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Information about resistance circuits is given on page 183 Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Information on “Plug and play” connection using system cabling Safety data as per ATEX
can be found from page 184 Maximum voltage Uo 9.6 V
Maximum current Io 10 mA
1) EMC: Class A product, see page 571
Maximum power Po 25 mW
Maximum voltage Um 253 V AC (125 V DC)
Conformance / approvals
Conformance CE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
II 3 G Ex nA nC IIC T4 Gc X
IECEx [Ex ia Ga] IIC; [Ex ia Da] IIIC; Ex nA nC IIC T4 Gc
UL, USA / Canada Class I Div 2; IS for Class I, II, III Div 1
Functional safety (SIL) SIL 2 according to EN 61508
Ordering data
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolating amplifier, 1-channel, input intrinsically safe,
output: PDT contact
Screw connection MACX MCR-EX-SL-NAM-R1) 2865434 1
Spring-cage conn. MACX MCR-EX-SL-NAM-R-SP1) 2924045 1
-
4.2 2.2 2.2 13
OUT2
OUT1 +
4.1
2.1 2.1 14
Faultsignal
GND
IN OUT2 4.2
1.2
+24V
1.1 2 signal outputs: N/O contact relay
4.1 Power
POWER
LFD +24V
Zone 0,1,2 GND
Zone 20,21,22
Div. 1,2
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolating amplifier for intrinsical- Floating switch contacts
Switch contacts with resistance circuit
ly safe operation of proximity sensors and No-load voltage 8 V DC ±10%
mechanical contacts installed in Ex areas. Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
Switching hysteresis < 0.2 mA
Line error detection Break 0.05 mA < IIN < 0.35 mA
– Input for NAMUR proximity sensors Short-circuit 100 Ω < RSensor < 360 Ω
(EN 60947-5-6), floating contacts or Switching output Relay output
Contact type 2 N/O contacts
contacts with resistance circuit, [Ex ia] Contact material AgSnO2, hard gold-plated
– Two relay signal outputs (N/O contact); Maximum switching voltage 250 V AC (2 A) / 120 V DC (0.2 A) / 30 V DC (2 A)
output 2 can be used as an error message Maximum switching capacity 500 VA
Recommended minimum load 5 V / 10 mA
output Mechanical service life 107 cycles
– Reversible direction of action (operating Switching behavior Can be inverted via slide switch
Maximum switching frequency 20 Hz (without load)
current or closed-circuit current behav- General data
ior) Supply voltage range 19.2 V DC ... 30 V DC
– Line fault detection (LFD), can be activat- Current consumption 30 mA (24 V DC)
Power dissipation < 950 mW
ed/deactivated, error message signaled by Number of channels 1
red flashing LED with de-excitation of Electrical isolation
output relay Input/output 375 V (Peak value in accordance with EN 60079-11)
Input/power supply 375 V (Peak value in accordance with EN 60079-11)
– Power supply and error indication possi- Input/supply, T connector 300 Vrms (Rated insulation voltage,
ble via the DIN rail connector surge voltage category II; pollution degree 2,
basic insulation as per EN 61010, EN 50178)
– LED displays for indicating supply voltage, 2.5 kV (50 Hz, 1 min., test voltage)
circuit state, and malfunctions to Output 1/output 2/input, power supply, T connector 300 Vrms (Rated insulation voltage,
surge voltage category III; pollution degree 2,
NAMUR NE 44 safe isolation as per EN 61010, EN 50178)
– 4-way electrical isolation 2.5 kV (50 Hz, 1 min., test voltage)
Ambient temperature range -20°C ... 60°C (Any mounting position)
– Up to SIL 2 according to EN 61508 Humidity 10% ... 95% (no condensation)
– Installation in zone 2 permitted Status indication Green LED (supply voltage)
LED yellow (switching state)
Notes: Red LED (line errors)
Housing material PA 66-FR
Information about the supply and error evaluation module as well Inflammability class according to UL 94 V0
as about the DIN rail connectors and marking material can be
Dimensions W / H / D 12.5 / 99 / 114.5 mm
found from page 182
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Information about resistance circuits is given on page 183 Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Information on “Plug and play” connection using system cabling Safety data as per ATEX
can be found from page 184 Maximum voltage Uo 9.6 V
Maximum current Io 10 mA
1) EMC: Class A product, see page 571
Maximum power Po 25 mW
Maximum voltage Um 253 V AC (125 V DC)
Conformance / approvals
Conformance CE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
II 3 G Ex nA nC IIC T4 Gc X
IECEx [Ex ia Ga] IIC; [Ex ia Da] IIIC; Ex nA nC IIC T4 Gc
UL, USA / Canada Class I Div 2; IS for Class I, II, III Div 1
Functional safety (SIL) SIL 2 according to EN 61508
Ordering data
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolating amplifier, 1-channel, input intrinsically safe,
output: 2 N/O contacts
Screw connection MACX MCR-EX-SL-NAM-2RO1) 2865450 1
Spring-cage conn. MACX MCR-EX-SL-NAM-2RO-SP1) 2924061 1
Faultsignal
IN2 - GND
OUT2 1.2
+24V
+ 1.1 2-channel, signal output: N/O contact relay
Power
POWER
LFD +24V
Zone 0,1,2 GND
Zone 20,21,22
Div. 1,2
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolating amplifier for intrinsical- Floating switch contacts
Switch contacts with resistance circuit
ly safe operation of proximity sensors and No-load voltage 8 V DC ±10%
mechanical contacts installed in Ex areas. Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
Switching hysteresis < 0.2 mA
Line error detection Break 0.05 mA < IIN < 0.35 mA
– 2-channel Short-circuit 100 Ω < RSensor < 360 Ω
– Input for NAMUR proximity sensors Switching output Relay output
Contact type 2 N/O contacts
(EN 60947-5-6), floating contacts or Contact material AgSnO2, hard gold-plated
contacts with resistance circuit, [Ex ia] Maximum switching voltage 250 V AC (2 A) / 120 V DC (0.2 A) / 30 V DC (2 A)
– Relay signal output (N/O contact) Maximum switching capacity 500 VA
Recommended minimum load 5 V / 10 mA
– Reversible direction of action (operating Mechanical service life 107 cycles
current or closed-circuit current behav- Switching behavior Can be inverted via slide switch
Maximum switching frequency 20 Hz (without load)
ior) General data
– Line fault detection (LFD), can be activat- Supply voltage range 19.2 V DC ... 30 V DC
ed/deactivated, error message signaled by Current consumption 35 mA (24 V DC)
Power dissipation <1W
red flashing LED with de-excitation of Number of channels 2
output relay Electrical isolation
– Power supply and error indication possi- Input/output 375 V (Peak value in accordance with EN 60079-11)
Input/power supply 375 V (Peak value in accordance with EN 60079-11)
ble via the DIN rail connector Input/supply, T connector 300 Vrms (Rated insulation voltage,
– LED displays for indicating supply voltage, surge voltage category II; pollution degree 2,
basic insulation as per EN 61010, EN 50178)
circuit state, and malfunctions to 2.5 kV (50 Hz, 1 min., test voltage)
NAMUR NE 44 Output 1/output 2/input, power supply, T connector 300 Vrms (Rated insulation voltage,
surge voltage category III; pollution degree 2,
– 3-way electrical isolation safe isolation as per EN 61010, EN 50178)
– Up to SIL 2 according to EN 61508 2.5 kV (50 Hz, 1 min., test voltage)
Ambient temperature range -20°C ... 60°C (Any mounting position)
– Installation in zone 2 permitted Humidity 5% ... 95% (no condensation)
Status indication Green LED (supply voltage)
Notes: LED yellow (switching state)
Information about the supply and error evaluation module as well Red LED (line errors)
as about the DIN rail connectors and marking material can be Housing material PA 66-FR
found from page 182 Inflammability class according to UL 94 V0
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Information about resistance circuits is given on page 183
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Information on “Plug and play” connection using system cabling Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
can be found from page 184 Safety data as per ATEX
1) EMC: Class A product, see page 571 Maximum voltage Uo 9.6 V
Maximum current Io 10.3 mA
Maximum power Po 25 mW
Maximum voltage Um 253 V AC (125 V DC)
Conformance / approvals
Conformance CE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
II 3 G Ex nA nC IIC T4 Gc X
IECEx [Ex ia Ga] IIC; [Ex ia Da] IIIC; Ex nA nC IIC T4 Gc
UL, USA / Canada Class I Div 2; IS for Class I, II, III Div 1
Functional safety (SIL) SIL 2 according to EN 61508
Ordering data
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolating amplifier, 2-channel, input intrinsically safe,
output: N/O contact
Screw connection MACX MCR-EX-SL-2NAM-RO1) 2865476 1
Spring-cage conn. MACX MCR-EX-SL-2NAM-RO-SP1) 2924087 1
IN2 -
OUT2 24...230 V –
1.2
~
+ AC/DC 2-channel, signal output: PDT relay,
1.1
Ordering data
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolating amplifier, 2-channel, input intrinsically safe,
output: Changeover contact
Screw connection MACX MCR-EX-SL-2NAM-R-UP1) 2865984 1
Spring-cage conn. MACX MCR-EX-SL-2NAM-R-UP-SP1) 2924249 1
-
4.2 2.2 2.2 -
OUT2
OUT1 +
4.1
2.1 2.1 +
Faultsignal
GND
IN OUT2 4.2
1.2
+24V
1.1 2 signal outputs: transistor (passive)
4.1 Power
POWER
LFD +24V
Zone 0,1,2 GND
Zone 20,21,22
Div. 1,2
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolating amplifier for intrinsical- Floating switch contacts
Switch contacts with resistance circuit
ly safe operation of proximity sensors and No-load voltage 8 V DC ±10%
mechanical contacts installed in Ex areas. Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
Line error detection Break 0.05 mA < IIN < 0.35 mA
Short-circuit 100 Ω < RSensor < 360 Ω
– Input for NAMUR proximity sensors Switching output 2 transistor outputs, passive
(EN 60947-5-6), floating contacts or Maximum switching voltage 30 V DC (per output)
Maximum switching current 50 mA (short-circuit resistant)
contacts with resistance circuit, [Ex ia] Drop (ΔU) < 1.4 V
– 2 signal outputs: transistor (passive); Switching behavior can be inverted using DIP switch
up to 5 kHz Maximum switching frequency 5 kHz
General data
– Signal output 2 can also be used as a fault Supply voltage range 19.2 V DC ... 30 V DC
signaling output Current consumption < 28 mA (24 V DC)
Power dissipation 800 mW
– Reversible direction of action (operating Number of channels 1
current or closed-circuit current behav- Electrical isolation
ior) Input/output 375 V (Peak value in accordance with EN 60079-11)
Input/supply, T-Connector 375 V (Peak value in accordance with EN 60079-11)
– Line fault detection (LFD), can be activat- Input/output/supply, T-Connector 300 Vrms (Rated insulation voltage,
ed/deactivated, error message signaled by surge voltage category II; pollution degree 2,
safe isolation as per EN 61010, EN 50178)
red flashing LED with inhibiting of transis- 2.5 kV (50 Hz, 1 min., test voltage)
tor output
Output 1/output 2 50 Vrms (Rated insulation voltage,
– Power supply and error indication possi- surge voltage category II; pollution degree 2,
ble via the DIN rail connector safe isolation as per EN 61010, EN 50178)
1 kV (50 Hz, 1 min., test voltage)
– LED displays for indicating supply voltage,
circuit state, and malfunctions to Ambient temperature range -20°C ... 60°C (Any mounting position)
Humidity 10% ... 95% (no condensation)
NAMUR NE 44 Status indication Green LED (supply voltage)
– 4-way electrical isolation LED yellow (switching state)
Red LED (line errors)
– Up to SIL 2 according to EN 61508 Housing material PA 66-FR
– Installation in zone 2 permitted Inflammability class according to UL 94 V0
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Notes: Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Information about the supply and error evaluation module as well Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
as about the DIN rail connectors and marking material can be Safety data as per ATEX
found from page 182 Maximum voltage Uo 9.6 V
Maximum current Io 10 mA
Information about resistance circuits is given on page 183
Maximum power Po 25 mW
Information on “Plug and play” connection using system cabling Maximum voltage Um 253 V AC (125 V DC)
can be found from page 184 Conformance / approvals
1) EMC: Class A product, see page 571 Conformance CE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
II 3 G Ex nA IIC T4 Gc X
IECEx [Ex ia Ga] IIC; [Ex ia Da] IIIC; Ex nA IIC T4 Gc
UL, USA / Canada Class I Div 2; IS for Class I, II, III Div 1
Functional safety (SIL) SIL 2 according to EN 61508
Ordering data
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolating amplifier, input intrinsically safe,
output: Transistor, passive
Screw connection MACX MCR-EX-SL-NAM-2T1) 2865463 1
Spring-cage conn. MACX MCR-EX-SL-NAM-2T-SP1) 2924074 1
Faultsignal
IN2 - GND
OUT2 1.2
+24V
+ 1.1 2-channel, signal output transistor (passive)
Power
POWER
LFD +24V
Zone 0,1,2 GND
Zone 20,21,22
Div. 1,2
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal NAMUR proximity sensors (EN 60947-5-6)
NAMUR isolating amplifier for intrinsical- Floating switch contacts
Switch contacts with resistance circuit
ly safe operation of proximity sensors and No-load voltage 8 V DC ±10%
mechanical contacts installed in Ex areas. Switching points > 2.1 mA (conductive) / < 1.2 mA (blocking)
Line error detection Break 0.05 mA < IIN < 0.35 mA
Short-circuit 100 Ω < RSensor < 360 Ω
– 2-channel Switching output Transistor output, passive
– Input for NAMUR proximity sensors Maximum switching voltage 30 V DC (per output)
Maximum switching current 50 mA (short-circuit resistant)
(EN 60947-5-6), floating contacts or Drop (ΔU) < 1.4 V
contacts with resistance circuit, [Ex ia] Switching behavior can be inverted using DIP switch
– Signal output transistor (passive); up to Maximum switching frequency 5 kHz
General data
5 kHz Supply voltage range 19.2 V DC ... 30 V DC
– Reversible direction of action (operating Current consumption < 34 mA (24 V DC)
Power dissipation 1000 mW
current or closed-circuit current behav- Number of channels 2
ior) Electrical isolation
– Line fault detection (LFD), can be activat- Input/output 375 V (Peak value in accordance with EN 60079-11)
Input/supply, T-Connector 375 V (Peak value in accordance with EN 60079-11)
ed/deactivated, error message signaled by Input/output/supply, T-Connector 300 Vrms (Rated insulation voltage,
red flashing LED with inhibiting of transis- surge voltage category II; pollution degree 2,
safe isolation as per EN 61010, EN 50178)
tor output 2.5 kV (50 Hz, 1 min., test voltage)
– Power supply and error indication possi-
Output 1/output 2 50 Vrms (Rated insulation voltage,
ble via the DIN rail connector surge voltage category II; pollution degree 2,
– LED displays for indicating supply voltage, safe isolation as per EN 61010, EN 50178)
1 kV (50 Hz, 1 min., test voltage)
circuit state, and malfunctions to
NAMUR NE 44 Ambient temperature range -20°C ... 60°C (Any mounting position)
Humidity 10% ... 95% (no condensation)
– 3-way electrical isolation Status indication Green LED (supply voltage)
– Up to SIL 2 according to EN 61508 LED yellow (switching state)
Red LED (line errors)
– Installation in zone 2 permitted Housing material PA 66-FR
Inflammability class according to UL 94 V0
Notes:
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Information about the supply and error evaluation module as well Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
as about the DIN rail connectors and marking material can be Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
found from page 182 Safety data as per ATEX
Information about resistance circuits is given on page 183 Maximum voltage Uo 9.6 V
Maximum current Io 10.3 mA
Information on “Plug and play” connection using system cabling
can be found from page 184 Maximum power Po 25 mW
Maximum voltage Um 253 V AC (125 V DC)
1) EMC: Class A product, see page 571 Conformance / approvals
Conformance CE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
II 3 G Ex nA IIC T4 Gc X
IECEx [Ex ia Ga] IIC; [Ex ia Da] IIIC; Ex nA IIC T4 Gc
UL, USA / Canada Class I Div 2; IS for Class I, II, III Div 1
Functional safety (SIL) SIL 2 according to EN 61508
Ordering data
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolating amplifier, 2-channel, input intrinsically safe,
output: Transistor, passive
Screw connection MACX MCR-EX-SL-2NAM-T1) 2865489 1
Spring-cage conn. MACX MCR-EX-SL-2NAM-T-SP1) 2924090 1
+ +
4.1 4.1 3.1 3.1
-
4.2
+
4.1
Faultsignal
GND
1.2
IN OUT 4.2 +24V
1.1 With line fault transparency
4.1 Power
POWER
LFD +24V
Zone 0,1,2 GND
Zone 20,21,22 Zone 2
– Power supply and error indication possi- Ambient temperature range -20°C ... 60°C (Any mounting position)
ble via the DIN rail connector Humidity 10% ... 95% (no condensation)
Status indication Green LED (supply voltage)
– LED indicators for supply voltage, status, LED yellow (switching state)
and fault according to NAMUR NE 44 Red LED (line errors)
Housing material PA 66-FR
– Plug-in screw or spring-cage connection Inflammability class according to UL 94 V0
technology Dimensions W / H / D 12.5 / 99 / 114.5 mm
– Safe 3-way electrical isolation Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
– Up to SIL 2 according to EN 61508 Safety data as per ATEX
– Installation in zone 2 permissible Maximum voltage Uo 9.6 V
Maximum current Io 10 mA
Notes: Maximum power Po 25 mW
Information on the supply and error evaluation module, DIN rail Maximum voltage Um 253 V AC (125 V DC)
connectors, system cabling, and marking material can be found Conformance / approvals
from page 182 Conformance CE-compliant, additionally EN 61326
Information about resistance circuits is given on page 183 ATEX II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
II 3G Ex nA IIC T4 Gc X
IECEx Yes
Functional safety (SIL) SIL 2
Ordering data
Pcs. /
Description Type Order No.
Pkt.
NAMUR isolation amplifier, intrinsically safe input, output with
line fault transparency
Screw connection MACX MCR-EX-SL-NAM-NAM 2866006 1
Spring-cage conn. MACX MCR-EX-SL-NAM-NAM-SP 2924883 1
DO
-
4.2 4.2 3.2 3.2 -
+
4.1 4.1 3.1 3.1 +
Faultsignal
- 2.2 2.2
DI
+ 2.1 2.1
-
OUT IN 4.2
Faultsignal
+ GND
1.2
4.1 Current limitation 48 mA,
+24V
1.1
POWER with line fault detection
Zone 0,1,2 LFD +24V
Zone 20,21,22 GND Zone 2
– Installation in zone 2 permissible Ambient temperature range -20°C ... 60°C (Any mounting position)
Humidity 10% ... 95% (no condensation)
Notes: Status indication Green LED (supply voltage)
Information on the supply and error evaluation module, DIN rail LED yellow (switching state)
connectors, system cabling, and marking material can be found Red LED (line errors)
from page 182 Degree of protection IP20
Housing material PA 66-FR
Inflammability class according to UL 94 V0
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Safety data as per ATEX
Maximum voltage Uo 25.3 V
Maximum current Io 94 mA
Maximum power Po 595 mW
Maximum voltage Um 253 V
Conformance / approvals
Conformance CE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
II 3(1) G Ex nA [ia Ga] IIC T4 Gc X
IECEx Yes
Functional safety (SIL) SIL 3 (applied for)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Solenoid driver, logic input, intrinsically safe output, line fault
detection
Screw connection MACX MCR-EX-SL-SD-23-48-LFD 2924867 1
Spring-cage conn. MACX MCR-EX-SL-SD-23-48-LFD-SP 2924870 1
DO
-
4.2 - 4.2 3.2 3.2 -
+ +
4.1 4.1 3.1 3.1 +
- -
4.2
+ +
- 4.1
OUT IN
+
Current limitation 25 mA
Zone 0,1,2
Zone 20,21,22
Div. 1,2
Zone 2
Div. 2
Functional safety
Ex:
Housing width 12.5 mm
Technical data
Input data
Input signal 20 V DC ... 30 V DC
Solenoid drivers for controlling intrinsi- Input current 10 mA DC ... 70 mA DC (45 mA for Ue = 24 V DC)
cally safe solenoid valves, alarm transmit- Output data
Output voltage 5.5 V DC (At 25 mA)
ters, and indicators installed in Ex areas. Current limitation 25 mA
No-load voltage 21.9 V DC
Internal resistance 641 Ω (Internal resistance Ri)
– 20 ... 30 V DC input Immunity to short-circuiting Yes
– Output [Ex ia] Response time tA 20 ms
– Various output characteristic curves com- General data
Power dissipation <1W
patible with the commercial solenoid Temperature coefficient 0.01%/K
valves Electrical isolation
– Loop-powered: The required power is Output/input 375 V (Peak value in accordance with EN 60079-11)
2.5 kV (50 Hz, 1 min., test voltage)
supplied via the control signal on the in- 300 Vrms (Rated insulation voltage,
surge voltage category II; pollution degree 2,
put side. safe isolation as per EN 61010, EN 50178)
– Mechanically compatible with DIN rail Ambient temperature range -20°C ... 60°C (Any mounting position)
connector Humidity 10% ... 95% (no condensation)
Status indication Yellow LED (switching state / status, lights up when output circuit is
– Galvanic 2-way isolation active)
– Up to SIL 3 as per EN 61508 Degree of protection IP20
Housing material PA 66-FR
– Installation in zone 2 permitted Inflammability class according to UL 94 V0
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Notes:
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
A list of suitable valves and notes for calculating a valve circuit Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
are available from the download center at Safety data as per ATEX
www.phoenixcontact.net/products
Maximum voltage Uo 25.1 V
Information on marking material can be found on page 127 Maximum current Io 39 mA
Maximum power Po 245 mW
Information on “Plug and play” connection using system cabling
can be found from page 184 Maximum voltage Um 253 V AC (125 V DC)
Conformance / approvals
Conformance CE-compliant, additionally EN 61326
ATEX II (1) G [Ex ia Ga] IIC/IIB/IIA
II (1) D [Ex ia Da] IIIC
II 3 G Ex nA IIC T4 Gc X
IECEx [Ex ia Ga] IIC; [Ex ia Da] IIIC; Ex nA IIC T4 Gc X
UL, USA / Canada Class I Div 2; IS for Class I, II, III Div 1
Functional safety (SIL) SIL 3
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Solenoid driver, loop-powered, output intrinsically safe
30
output voltage UV [V]
21,9 V
20
10
5,5 V
0
0 10 20 30 40 50 60
output current IV [mA]
375 V (Peak value in accordance with EN 60079-11) 375 V (Peak value in accordance with EN 60079-11) 375 V (Peak value in accordance with EN 60079-11)
2.5 kV (50 Hz, 1 min., test voltage) 2.5 kV (50 Hz, 1 min., test voltage) 2.5 kV (50 Hz, 1 min., test voltage)
300 Vrms (Rated insulation voltage, 300 Vrms (Rated insulation voltage, 300 Vrms (Rated insulation voltage, surge voltage category II; pollu-
surge voltage category II; pollution degree 2, surge voltage category II; pollution degree 2, tion degree 2, safe isolation as per EN 61010, EN 50178)
safe isolation as per EN 61010, EN 50178) safe isolation as per EN 61010, EN 50178)
-20°C ... 60°C (Any mounting position) -20°C ... 60°C (Any mounting position) -20°C ... 60°C (Any mounting position)
10% ... 95% (no condensation) 10% ... 95% (no condensation) 10% ... 95% (no condensation)
Yellow LED (switching state / status, lights up when output circuit is Yellow LED (switching state / status, lights up when output circuit is Yellow LED (switching state / status, lights up when output circuit is
active) active) active)
IP20 IP20 IP20
PA 66-FR PA 66-FR PA 66-FR
V0 V0 V0
12.5 / 99 / 114.5 mm 12.5 / 99 / 114.5 mm 12.5 / 99 / 114.5 mm
0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
30 30 30
output voltage UV [V]
output voltage UV [V]
24 V
21,9 V 21,9 V
20 20 20
12,9 V
10,0 V 10,5 V
10 10 10
0 0 0
0 10 20 30 40 50 60 0 10 20 30 40 50 60 0 10 20 30 40 50 60
output current IV [mA] output current IV [mA] output current IV [mA]
Faultsignal
from diode, protected against polariza-
tion 1.2 –
PWR 1
– Supply current up to 3.75 A 1.1 +
– Relay output (PDT) and flashing LED for LFD +24V
Power and error message module
GND
error messages
– Error message in the event of a power
supply failure or fuse fault
Ex: // Applied for: cUL / UL
– Bus cable fault message for Housing width 17.5 mm
MACX MCR-...(2)NAM... devices con- Technical data
nected via DIN rail connectors Input data
– Replaceable fuse Input signal 19.2 V DC ... 30 V DC
– Installation in zone 2 permissible Redundant supply yes, decoupled from diodes
Polarization and surge protection Yes
Output data
Maximum output signal 3.75 A
ME 6,2 TBUS... T-Connector Output voltage (Input voltage - max. 0.8 V at 3.75 A)
DIN rail connector (5-pos.) for bridging Switching output Relay
the supply voltage of 12.5 mm wide MACX Contact type
Contact material
1 PDT
Gold (Au)
analog Ex modules. Maximum switching voltage 50 V AC (2 A)
– Reduces wiring costs General data
Current consumption
– System can be extended or module re- Ambient temperature range -20°C ... 60°C (Any mounting position)
placed even while process is active Humidity 5% ... 95% (no condensation)
– Inter-extendable Fuse 5 A (replaceable), slow-blow 250 V AC
Status indication 1 x red LED (error)
2 x green LEDs (PWR1 and PWR2)
Housing material Polyamide (PA 6.6)
Inflammability class according to UL 94 V0
Dimensions W / H / D 17.5 / 99 / 114.5 mm
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Spring-cage connection (solid/stranded/AWG) 0.2 ... 1.5 mm² / 0.2 ... 1.5 mm² / 24 - 16
Conformance / approvals
Conformance CE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X
IECEx Ex nA nC IIC T4 Gc X
UL, USA / Canada UL 61010
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Supply and error message module, including the relevant
DIN rail connector ME 17,5 TBUS 1,5/5-ST-3,81 GN
Accessories
DIN rail connector (TBUS), for bridging the supply voltage, ME 6,2 TBUS-2 1,5/5-ST-3,81 GN 2869728 10
can be snapped onto 35 mm DIN rails as per EN 60715,
with UL approval
Ordering data
Pcs. /
Description Color Type Order No.
Pkt.
UniCard, with self-adhesive plastic labels
Accessories
Resistance circuit
Double-level terminal block with resis-
tance circuit according to NAMUR for line
fault detection in the case of mechanical
contacts
Important:
– For intrinsically safe circuits, only in com-
bination with D-UKK 3/5 cover
Ordering data
Pcs. /
Description Color Type Order No.
Pkt.
Double-level terminal block, with preassembled resistors
The TC-D37SUB-ADIO16-EX-P-UNI
universal termination carrier is a compact
solution which connects isolating amplifiers
from the MACX Analog Ex series to analog
or binary input/output cards of automation
systems.
The TC-D37SUB-AIO16-EX-PS-UNI
termination carrier design, when combined
with the MACX MCR-S-MUX HART multi-
plexer, also enables communication be-
tween HART-capable field devices and a
management system.
– Connection of up to 16 single-channel
(Ex i-)isolating amplifiers Housing width 244 mm
– Universal 1:1 signal routing to a Technical data
37-pos. D-SUB plug-in connector General data
– For system cables with D-SUB socket and Connection to the control system level D-SUB pin strip
open ends for universal connection Number of positions 37
Maximum operating voltage < 50 V DC (Per signal/channel)
– Redundant supply and monitoring in Maximum permissible current 1 A (Signal/channel)
separate DIN rail module Rated insulation voltage 50 V
Surge voltage category II
Notes: Pollution degree 2
Contact us: specific termination carrier designs for I/O modules of Rated surge voltage 0.5 kV
various automation systems are available, planned or can be im- Air and creepage distances DIN EN 50178 ( Basic insulation )
plemented according to your specifications. Degree of protection IP20
Ambient temperature range -40°C ... 80°C (Please observe module specifications)
1) EMC: Class A product, see page 571
Shock 15g, according to IEC 60068-2-27
Vibration (operation) 2g, according to IEC 60068-2-6
Inflammability class according to UL 94 V0
Dimensions W / H / D 244 / 170 / 160 mm
Power supply via power module
Input voltage range 19.2 V DC ... 30 V DC
Redundant supply yes, decoupled from diodes
Polarization and surge protection Yes
Fuse 5 A Slow-blow (can be exchanged)
Status indication 1 x red LED (error)
2 x green LEDs (PWR1 and PWR2)
Switching output 1 PDT
Contact material Au
Maximum switching voltage 50 V DC (0.3 A) / 30 V DC (2 A) / 33 V AC (2 A)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Universal termination carrier for 16 MACX MCR-EX isolators
TC-D37SUB-ADIO16-EX-P-UNI 2924854 1
- With connection for MACX MCR-S-MUX HART multiplexer TC-D37SUB-AIO16-EX-PS-UNI1) 2902932 1
Accessories
Supply and error message module MACX MCR-PTB 2865625 1
MACX MCR-PTB-SP 2924184 1
HART multiplexer, 32-channel MACX MCR-S-MUX 2865599 1
X1 DSUB 37
X20 COMBICON
4 (-) PWR1
6 (-) PWR2
Alarm
3 (+)
5 (+)
20
21
22
23
24
25
26
27
28
10
29
11
30
12
31
13
32
14
33
15
34
16
35
1
9
1
2
CH10
CH11
CH12
CH13
CH14
CH15
CH16
PW1
PW2
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
PTSM
+
+
-
-
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
3.2
3.1
1.1
1.2
3.2
2.1
2.2
MACX
MCR-
PTB
transmitted without affecting measured Data transmission display Two yellow “Tx” and “Rx” “HART” LEDs
value processing Display error Red “ERR” LED (flashes in case of an error in the HART bus)
– HART field devices connected via univer- RS-485 interface
sal HART connection boards; direct con- Connection method D-SUB-9 socket
nection if processing non-Ex signals, with Signal RS-485
Data flow control/protocols Compatible with OPC HART server, PDM, PRM, and FDT/DTM
separate Ex i signal isolator connected
upstream if processing Ex signals Number of HART multiplexers per bus segment Max. 31
Address setting 0...127; using a rotary switch at the front
– Power supplied via HART connection Data rate 9600 / 19200 / 38400 / 57600 [bps]; via rotary switch at the front
board
Transmission length ≤ 1200 m
Display Two yellow “Tx” and “Rx” “RS-485” LEDs
Notes: General data
Supply voltage range 18 V ... 31.2 V
1) EMC: Class A product, see page 571 Nominal supply voltage 24 V DC
Current consumption 55 mA
Power consumption 1.35 W
Operating voltage display Green “PWR” LED
Undervoltage monitoring Yes (no faulty devices / output states)
Ordering data
Pcs. /
Description Type Order No.
Pkt.
HART multiplexer, 32-channel including two 14-wire flat-ribbon
cables
MACX MCR-S-MUX 2865599 1
Accessories
Universal termination carrier for 16 MACX MCR-EX isolators
General data
Supply voltage range 12 V DC ... 30 V DC
Current consumption < 3.5 mA
Step response (10 - 90%) <2s
Transmission error Resistance thermometers 0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000)
Thermocouple sensors Type 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R)
Resistance-type sensors ±0.1 Ω (10...400 Ω), ±1.5 Ω (10...2000 Ω)
Voltage sensor ±20 µV (-10...100 mV)
Test voltage input/output 2 kV AC (50 Hz, 1 min.)
Switch on delay time 4s
Standards/regulations NAMUR recommendation NE 21
Housing material Polyamide PA non-reinforced
Inflammability class according to UL 94 V0
Dimensions W / H / D 12.5 / 99 / 114.5 mm
Connection method Plug-in screw connection
Screw connection solid / stranded / AWG 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14
Safety data as per ATEX MCR-FL-TS-LP-I-EX MCR-FL-T-LP-I-EX
Maximum voltage Ui 30 V 30 V
Maximum current Ii 100 mA 100 mA
Maximum power Pi 750 mW 750 mW
Maximum voltage Uo 5 V DC 4.4 V DC
Maximum current Io 5.9 mA 9.6 mA
Maximum power Po 7.2 mW 10.6 mW
Gas group II A II B II C II A II B II C
- max. external inductivity Lo [mH] 100 100 100 100 100 100
- max. external capacity Co [µF] 10 10 2 12 12 2.4
Maximum ambient temperature T4 = 85°C, T5 = 70°C, T4 = 85°C, T5 = 65°C,
T6 = 55°C T6 = 50°C
Conformance / approvals
Conformance CE-compliant CE-compliant
ATEX II 2(1) G Ex ia IIC T6 II 2(1) G Ex ia IIC T4...T6
UL, USA / Canada cULus cULus
Functional safety (SIL) SIL 2 according to EN 61508 -
-
1 DC 5 OUT 1
D Ordering data
2 D DC A 6 GND 1
Pcs. /
Description Type Order No.
3 Pkt.
Technical data
Measuring input
Resistance thermometers Pt, Ni (100, 500, 1000); min. measurement range 10 K
Thermocouple sensors B, C, D, E, J, K, L, N, R, S, T, U; min. measurement range 50 K/500 K
General data
Supply voltage range 12 V DC ... 30 V DC
Current consumption < 3.5 mA
Step response (10 - 90%) <2s
Transmission error Resistance thermometers 0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000)
Thermocouple sensors Type 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R)
Resistance-type sensors ±0.1 Ω (10...400 Ω), ±1.5 Ω (10...2000 Ω)
Voltage sensor ±20 µV (-10...75 mV)
Test voltage input/output 2 kV AC (50 Hz, 1 min.)
Switch on delay time 6s
Degree of protection IP00, IP66 (integrated in the connecting head)
Mounting position Connecting head according to DIN 43729 form B
Connection Installation in connection head according to DIN 43729 form B
Standards/regulations NAMUR recommendation NE 21
Housing material Polycarbonate, PC
Inflammability class according to UL 94 V0
Screw connection solid / stranded / AWG 0.2 ... 1.75 mm² / 0.2 ... 1.75 mm² / 24 - 15
Safety data as per ATEX
Maximum voltage Ui 30 V
Maximum current Ii 100 mA
Maximum power Pi 750 mW
Maximum voltage Uo 5 V DC
Maximum current Io 5.4 mA
Maximum power Po 6.6 mW
Gas group II A II B II C
- max. external inductivity Lo [mH] 100 100 100
- max. external capacity Co [µF] 9.9 9.9 2
Maximum ambient temperature Category 1: T4 = 60°C, T5 = 50°C, T6 = 40°C
∅44 Category 2: T4 = 85°C, T5 = 70°C, T6 = 55°C
∅33
Conformance / approvals
Conformance CE-compliant
4 5
ATEX II 1 G and II 2 G Ex ia IIC T6/T5/T4
∅5
Ordering data
2
1 Pcs. /
Description Type Order No.
Pkt.
MCR temperature measuring transducer, smart, for
resistance thermometers, thermocouples, resistance-type sensors,
and voltage sensors
21
MCR-FL-HT-TS-I-EX 2864545 1
General data
Supply voltage range 8 V DC ... 30 V DC
Current consumption < 3.5 mA
Step response (10 - 90%) <2s
Transmission error Resistance thermometers 0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000)
Thermocouple sensors Type 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R)
Resistance-type sensors ±0.1 Ω (10...400 Ω), ±1.5 Ω (10...2000 Ω)
Voltage sensor ±20 µV (-10...100 mV)
Test voltage input/output 2 kV AC (50 Hz, 1 min.)
Switch on delay time 6s
Degree of protection IP00, IP66 (integrated in the connecting head)
Mounting position Connecting head according to DIN 43729 form B
Connection Installation in connection head according to DIN 43729 form B
Standards/regulations NAMUR recommendation NE 21
Housing material Polycarbonate, PC
Inflammability class according to UL 94 V0
Screw connection solid / stranded / AWG 0.2 ... 1.75 mm² / 0.2 ... 1.75 mm² / 24 - 15
Safety data as per ATEX
Maximum voltage Ui 30 V
Maximum current Ii 100 mA
Maximum power Pi 750 mW
Maximum voltage Uo 8.2 V DC
Maximum current Io 4.6 mA
Maximum power Po 9.35 mW
Gas group II B II C
- max. external inductivity Lo [mH] 8.5 4.5
- max. external capacity Co [µF] 1.9 0.974
Maximum ambient temperature Category 1: T4 = 60°C, T5 = 50°C, T6 = 40°C
∅44 Category 2: T4 = 85°C, T5 = 70°C, T6 = 55°C
∅33
Conformance / approvals
Conformance CE-compliant
4 5
ATEX II 1 G Ex ia IIC T6/T5/T4
∅5
6
∅7
Ordering data
2
Pcs. /
Description Type Order No.
1 Pkt.
MCR temperature measuring transducer, for
resistance thermometers, thermocouples, resistance-type sensors,
and voltage sensors
MCR-FL-HT-T-I-EX 2864532 1
21
Accessories
MCR-PAC-T-USB 2309000 1
Accessories
Adapter cable, stranded, 9-pos. D-SUB socket on 25-pos. D-SUB PSM-KAD 9 SUB 25/BS 2761295 1
pin
Ordering data
Pcs. /
Description Type Order No.
Pkt.
Shield fast connection
For Ø 3-6 mm SSA 3-6 2839295 10
For Ø 5-10 mm SSA 5-10 2839512 10
Accessories
Test plug
Ordering data
Pcs. /
Description Color Type Order No.
Pkt.
Test plug, consisting of:
Metal part for 2.3 mm Ø socket hole and MPS-MT 0201744 10
Insulating sleeve, for MPS metal part red MPS-IH RD 0201676 10
white MPS-IH WH 0201663 10
blue MPS-IH BU 0201689 10
yellow MPS-IH YE 0201692 10
green MPS-IH GN 0201702 10
gray MPS-IH GY 0201728 10
black MPS-IH BK 0201731 10