Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Manufacturer’s review of data from APT

1 APT key data


APT case number 31047
APT sign off (date) 2021-07-01
APT data received 2021-07-02
Vessel name CY ATLANTIC
IMO number 9640176
MMSI number 538006454
VDR Model DM400 – VDR
VDR serial number A06971-002564
Technicians ID # 12082
Technicians name ABDUL WAJID MOODAMBAIL
Technicians company Al Nakheel Electronics
Technicians certificate number D127196 Valid Yes

2 Data items to be recorded


Data item VDR (2014) VDR S-VDR Note
MSC.333(90) A.861(20) MSC.163(78)
Date and time YES
Ship’s position YES
Speed YES
Heading YES
Bridge audio YES
Communication audio YES
Radar data YES
ECDIS NO
AIS NO
Echo sounder YES
Rudder order and response YES
Engine order and response YES
Hull opening (doors) status NO
Watertight and fire door status NO
BNWAS NO
Main Alarms / Bridge alert YES
management
Electronic logbook NO
Inclinometer NO
Acceleration and hull stresses NO
Wind speed and direction YES
Optional input.
For VDR (MSC.333(90): Inclinometer with an electronic output must be recorded if fitted. Electronic logbook must be recorded if fitted.
For VDR (A.861(20)): Recording of AIS is optional.
For all VDR: Acceleration and hull stresses must be recorded where ship is fitted with IMO mandated monitoring equipment. Wind speed
and direction must be recorded where ship is fitted with suitable sensor.
For S-VDR: Must be recorded if sensor data is available in accordance with IEC61162).

Radar data may be substituted by AIS if the radar for technical reasons cannot be connected to an S-VDR.

Page 1 of 4
3 Check of report from manual check
3.1 Technician notes

4 Check of verification report


4.1 Installation
4.1.1 Capsule cable
The capsule cable should be fixed with metal plate to ensure good ground contact.
Unshielded portion of the capsule cable should be as short as possible with twisted pairs. Refer to
the VDR installation manual.

4.1.2 Power plug


The missing L-bracket should be in place to prevent accidental disconnection of the AC plug. Use
P/N: 2304663 bracket kit.

Page 2 of 4
4.2 APT
4.2.1 Serial inputs
Enable DBK to be transmitted in the echo sounder signal or remove it from formatter in the echo
sounder channel.

The Pump Alarm signal was not detected in the APT data. Sample of all signals should be available
for verification.

4.2.2 Radar image


The radar image is shifted. Re-calibrate by adjusting horizontal offset is required.

4.2.3 Software upgrade


The S-VDR/VDR should be upgraded to the latest software. Version 4.12 is available on Danelec
partner site.

4.3 VDR explorer


The VDR Explorer is not configured (almost default). Each signal recorded in the VDR should have
dedicated object.

4.4 VDR status


The log file indicates the problem with the capsule. The diagnostic using “Danelec service tools” of
the capsule should be performed.

Page 3 of 4
5 Danelec Marine’s acceptance
A major issue and a number of minor issues (which must be fixed latest at the next APT) were
discovered during the review.

Danelec Marine has reviewed the APT data and will issue a certificate when the issue described in
section 4.2.1 is resolved.

Danelec Marine A/S


Copenhagen
8. July 2021