Annex 1: (RA Bill 1)

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

Annex 1 (RA Bill 1)

Mandatory Quality Tests, Tests Reqd as


Relevant IS Frequency as per Frequency as per Test Tests Done at Lab
Sl No but not limited to, as per Qty Consumed per available Rejecte Balance Remarks
Code CPWD availble FQP Conducted
CPWD FQP Passed d
A R/F Steel 285
1 test for each
1 Rolling Margin Not Mandatory
upto 10 mm - 25 MT dia
upto 10 mm - 42 MT
12mm to 16 mm - 35 MT 32 dia rod TPA test to be
12mm to 16 mm - 45 MT
More than 20 mm - 45 done before submitting
2 Physical and Chemical Test IS 1786 More than 20 mm - 50 MT 10 6 4
MT
next bill. Test report of
other rods should also be
B Construction Water IS 3085
1 PH Value 3 MONTHS 3 months 2 2 2 0 0 Ok
2 Percentage of solids 3 MONTHS Once per source 1 1 1 0 0 Ok
2.1 Chlorides 3 MONTHS Once per source 1 1 1 0 0 Ok
2.2 Suspended Matter 3 MONTHS Once per source 1 1 1 0 0 Ok
2.3 Sulphates 3 MONTHS Once per source 1 1 1 0 0 Ok
2.4 Inorganic solids 3 MONTHS Once per source 1 1 1 0 0 Ok
2.5 Organic solids 3 MONTHS Once per source 1 1 1 0 0 Ok
C Cement
1 Fineness IS 4031 (P-II) 50 T per week/lot 5 6 6 0 0 Ok
2 Soundness IS 4031 (P-III) 50 T per week/lot 5 5 5 0 0 Ok
3 Initial and Final setting time IS 4031 (P-V) 50 T per week/lot 5 6 6 0 0 Ok
4 Compressive Strength IS 4031 (P-VI) 50 T per week/lot 5 5 5 0 0 Ok
5 Consistency IS 4031 (P-VI) 50 T per week/lot 5 6 6 0 0 Ok
D Fine Aggegates 749.69
Organic and deleterious
1 IS 2386 (P-II) 20 Cum
materials
2 Silt Content IS 2386 (P-II) 20 Cum 5 nos 5 23 23 0 0 Ok
3 Particle size distribution IS 2386 (P-I) 40 Cum 5 nos 5 23 23 0 0 Ok
E Coarse Aggegates 1172.60
1 Soft and deleterious materials IS 2386 (P-II) 40 cum
2 Particle size distribution IS 2386 (P-I) 45 cum 7 NOS 7 23 23 0 0 Ok
3 Surface Moisture IS 2386 (P-III) 40 cum 7 nos 7 23 23 1 0 Ok
4 10% FINE VALUE IS 2386 40 cum Not Done
5 Specific Gravity IS 2386 40 cum Not Done
6 Bulk Density IS 2386 40 cum Not Done
7 Aggregate Crushing Strength IS 2386 40 cum N/A
8 Aggregate Impact Value IS 2386 40 cum 7 nos 7 23 23 0 0 Ok
9 Flakiness and Elongation Index IS 2386 NIL 7 nos 7 23 23 0 0 Ok
F Concrete 2732
1 Slump Test CPWD Spec 50 cum Every 3rd TM 152 200 200 0 0 Ok
1 -5 = 1 set, 6 -15 = 2 2 -5 = 1 set, 6 -15 = 2
Ok (It should be taken care
sets, 16-30 = 3 sets, 31- sets, 16-30 = 3 sets, 31-
2 Cube Test IS 456 64 64 64 0 0 to test equal sets of cubes
50=4 sets, then for 50=4 sets, then for
on 7 & 28 days)
every 50 cum, 1 set every 50 cum, 1 set
Daily before starting
3 Moisture correction CPWD Spec 38 38 38 0 Ok
the pour

Documents Submitted:

Documents to be No of
Sl. No. submitted with RA Bill Documents/checklists Qty
1 submitted

1 Material Test Pan 1


 
2 Construction Water 1  
3 Cement test:    
a) MTC 4
 
b) Fineness of Cement 6  
c) NC,IST,FST 6
 
d) Soundness 5
 
Compressive Strength
e) 5
3,7 & 28 days  
Documents to be No of
Sl. No. submitted with RA Bill Documents/checklists Qty
1 submitted
4 Steel tests:    
MTC-20 mm dia Jindal
a) 8
Steel FE550D 225.504
MTC-32 mm dia Jindal
b) 2
Steel FE550D 48.436
MTC-20 mm dia Shyam
c) 8
Steel FE550D 124.96
MTC-12 mm dia Shyam
d) 2
Steel FE550D 49.92

MTC-16 mm dia Shyam


e) 5
Steel FE550D
92.87
MTC-8 mm dia Shyam
f) 5
Steel FE550D 71.41
MTC-10 mm dia Shyam
g) 2
Steel FE550D 49.89
MTC-25 mm dia Shyam
h) 2
Steel FE550D 49.97

3rd PartyPhysical and


i) 1
Chemical
 
5 Admixture:    
a) MTC 1
 
6 Concrete Tests:    
Concrete Cube
a) compressive stregth - 7 25 2850.25
days (Sets)
Concrete Cube
b) compressive stregth - 39 1532.25
28 days (Sets)
7 Aggregates test:    
Sieve Analysis 20 and
a) 23
10 mm  
b) Sieve Analysis sand 23  
F.I. & E.I. of Coarse
c) 23
Aggergates  
d) Impact Value 23  
e) Silt content 23  