DR6001 - MobiEye700 Overview - V2.0 - EN

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 39

MobiEye700 Overview

Radiography product global technical support department


Service@mindray.com
Version number: V2.0
No.: MDR-16016-MobiEye700

© 2011 Mindray Confidential


MobiEye700 Overview
 Course profiles:
 This course is first lesson of DigiEye700 products professional classes, mainly introduces 3 parts: the
configuration of the product, the advantages and the main competition machine of the other company. The
most important part is the product configuration and performance advantage.

 After learning this course, the engineers can grasp the configuration and performance of MobiEye700, such
as market positioning and comparison of advantages, so as to have overall understanding of this product.

 Before learning this course, should have to learn the following courses or the relevant knowledge:
《DR0101_X ray basic principle and concept》
《DR0102_X ray machine structure and the core parts》
《DR0103_Radiation protection and safety operation》

2 © 2011 Mindray Confidential


X-Ray Generation

Anode

Generator

Cathode

The electrons from the cathode bombard the anode target, and then producing the X-ray.

3 © 2011 Mindray Confidential


X-Ray Generation The filament current to make the electrons.
The High Voltage to make the strong electric field, and the electrons will move very fast.
The moving electrons bombard the target to make the X-ray, and make the tube current.

Tube Voltage:
KV

e-
Expose time:
Filament Current
ms
A

Cathode Anode

Tube Current : Iq=Q/t:


mA
4 © 2011 Mindray Confidential
X-Ray Protection
 X-Ray protection principle
 Time protection
 The longer exposure , the more x-ray dose, so
the working staff should control working time in 3 principles of X-ray Protection
X-ray room.

 Distance Protection Time


 The longer distance, the less x-ray dose, so the Shielding
working staffs should keep far away from X-ray
room.

 Shielding protection
 Protection tools, such as: lead glove, lead apron.
 The most impotence: Shielding Room, shielding Distance
screen.

5 © 2011 Mindray Confidential


X-Ray Protection
Lead
glass
window

6 © 2011 Mindray Confidential


DR System Introduction
Ion chamber Detector

Anode
Rotating
anode Monitor
Generator Workstation

Cathode/Filament

7 © 2011 Mindray Confidential


DR System Introduction 380VAC

PDC

380VAC Power Supply Distribution part

220VAC、30VAC、24VDC、12VDC、5VDC 220VAC

Detector power
4、System control and
1、Generator 5、Workstation
cabinet (IPC) synchronization

U
arm
Tube Detector
75KV
75KV

support support

Suspension Wall stand

3. Detector
Collimator


6.
2、Tube

7. Grid 6 7 8

3
8. Ion chamber

8 © 2011 Mindray Confidential


DR System Introduction

U-arm System Ceiling Suspending System

DigiEye 560 DigiEye 760 Plus DigiEye 760 Smart DigiEye 760 Dual

Stationary DR
9 © 2011 Mindray Confidential
10 © 2011 Mindray Confidential
MobiEye700 Overview--Questions
1. How many MobiEye700 types and the differences of them?
2. How many types of X-ray tube which the MobiEye700 can be optional and the differences of the tube
parameter?
3. How many kinds of detectors that the MobiEye700 can be optional and the differences of the detector
parameter?
4. What are the optional accessories for MobiEye700 ?
5. What's the dual mode exposure? What's the compartment exposure?
6. How to switch the manual mode and the automatic mode?

11 © 2011 Mindray Confidential


MobiEye700 Overview
1、MobiEye700 product configuration
2、MobiEye700 product advantage
Bionic arm
Small body + Super power
Dual mode exposure + Excellent strong endurance
Manual-automatic integration + Remote control
Detector locker + Online charge
Wireless detector + Free to share
3、MobiEye700 competitor analysis
Shimadzu
Siemens
Carestream
Sedecal
IMD
Browiner
Perlong

12 © 2011 Mindray Confidential


1、MobiEye700 Product Configuration
Product code
DR60

Digital Radiography: MobiEye700 Analog X-ray machine: MobiEye700A

NOTE: The power of machine can be chosen 30KW or 50KW, It depend on the tube.

13 © 2011 Mindray Confidential


1、MobiEye700 Product Configuration
 X-ray tube Tube Toshiba E7894X IAE MXT700

 Toshiba E7894X Max Voltage 150kV 150kV


Focus size 1.2/0.6 1.2/0.6
 IAE MXT700
Target Angle 12.5° 12°
Anode heat 140kHU 300kHU
capacity
Inherent 0.9mmAl/75kV 1.2mmAl/80kV
Filtration
Total filtration 1.8mmAl/75kV 1.5mmAl/80kV

Toshiba IAE

Toshiba E7894X IAE MXT700


For MobiEye700 For MobiEye700
(30KW) (50KW)
115-037852-00 115-037853-00
(024-000649-00) (024-000706-00)

14 © 2011 Mindray Confidential


1、MobiEye700 Product Configuration
Detector Mindray Toshiba
 Detector MPX3543R FDX3543RPW
 Mindray MPX3543R wireless/wired Model Portability detector
 Toshiba FDX3543RPW wireless Communication mode Wireless/wired wireless
Material CsI CsI
Type a-Si a-Si
Size 35cm×43cm 35cm×43cm
Matrix 2560×3072 pixel 2466×3040 pixel
A/D transform 16 bits 14 bits
Image output 16 bits 16 bits
Transmitting power ≤27 dbm or ≤500 mw ≤27 dbm or ≤500 mw
Frequency 2.4G/5G 2.4G/5G
Mindray

Toshiba
15 © 2011 Mindray Confidential
1、MobiEye700 Product Configuration
 Screen Display screen Touch screen(DR) Control panel
 Touch screen (analog machine)
size 19 inch /
 Control panel
type color、liquid crystal、 /
touch screen
dot pitch 0.294mm /
resolution 1280*1024 /
maximum
300cd/㎡ /
brightness

Touch screen Control panel Only for MobiEye700A

16 © 2011 Mindray Confidential


1、MobiEye700 Product Configuration
 Other accessories
 Stand column:WS280
 Movable patient table:MTAB-065
 Portable workstation:iPad
 DAP:Only for international
 Scanner:USB interface
 Detector handle:Optional
 Grid:1.8m/1.3m/1.0m
 Ion chamber:using in the wall stand column

17 © 2011 Mindray Confidential


MobiEye700 Overview
1、MobiEye700 product configuration
2、MobiEye700 product advantage
Bionic arm
Small body + Super power
Dual mode exposure + Excellent strong endurance
Manual-automatic integration + Remote control
Detector locker + Online charge
Wireless detector + Free to share
3、MobiEye700 competitor analysis
Shimadzu
Siemens
Carestream
Sedecal
IMD
Browiner
Perlong

18 © 2011 Mindray Confidential


2、MobiEye700 product advantage
The old time mobile digital radiography Complain:
 Too Big:For this reason, only can choose the small power machine.

 Too Heavy:It is too hard to push the machine, and the floor will be crush.

 Difficult position:It is hard to position or even impossible.

 Small battery capacity:Need to charge the battery every day.

 High maintenance costs:Need to replace the battery every year.

 Small power:It can’t do the compartment operation,difficult to replace the fixed DR.

 The wireless detector is easy lost.

19 © 2011 Mindray Confidential


2、MobiEye700 product advantage
The new definition for
Mobile DR
Bionic arm
Super power
Dual mode exposure Robot

Small body Excellent strong endurance

Remote control

Manual–automatic integration Detector locker

Wireless detector

Free to share Online charge

20 © 2011 Mindray Confidential


2、MobiEye700 product advantage
 Bionic arm
 The lower stand column high, the bigger coverage area
 The tube-collimator can stop at any position

mantis

21 © 2011 Mindray Confidential


2、MobiEye700 product advantage
 Bionic arm
 The lower stand column high, the bigger coverage area The range of the tube movement.
 The tube-collimator can stop at any position

Folding arm Telescopic arm

2300mm 1250mm
2020mm
1280mm

22 © 2011 Mindray Confidential


2、MobiEye700 product advantage
 Small body + Super power
 Small body: 470mm
 Super power: 30KW/50KW. It can be used as the stationary DR (compartment operation)

23 © 2011 Mindray Confidential


2、MobiEye700 product advantage
 Small body + Super power
 The double anti-collision function
 Fit for the Asian female technician to operate

Ultrasonic warning Front bumper larger perspective


Column light flashing Stop moving

24 © 2011 Mindray Confidential


2、MobiEye700 product advantage
 Small body + Super power
 Easy to complete the difficult position in the department of orthopedics ward

1、Can stop at any position , no need to


follow first vertical then horizontal
2、Immediately stop
3、One-hand control
4、Two-side control collimator
5、Far-end movement control

25 © 2011 Mindray Confidential


2、MobiEye700 product advantage
 Dual mode exposure + Excellent strong endurance
 Can exposure on the AC power supply and battery power supply, it’s the real dual mode exposure
 One time charge, it can be used 7 days
 The charge speed is too fast, it can be full charged in 3.5h (27℃)
 Quick charging function: 5 mins charging can make exposure 70 times

7 Days
70 Kilometers
700 Exposure times

Endurance Endurance Battery Charge


mileage exposure life speed

26 © 2011 Mindray Confidential


2、MobiEye700 product advantage
 Manual-automatic integration + Remote control
 Easy to transform automatic mode to manual mode
 Use the remote control mode, can remote exposure

27 © 2011 Mindray Confidential


2、MobiEye700 product advantage
 Detector locker + Online charge
 Detector locker: It makes the detector safer
 Online charge: it can charge all the time in the detector box

attendance +15VDC GND

28 © 2011 Mindray Confidential


2、MobiEye700 product advantage
 Wireless detector + Free to share
Use Mindray wireless detectors, different machine can
share easily.(M-share)

29 © 2011 Mindray Confidential


MobiEye700 Overview
1、MobiEye700 product configuration
2、MobiEye700 product advantage
Bionic arm
Small body + Super power
Dual mode exposure + Excellent strong endurance
Manual-automatic integration + Remote control
Detector locker + Online charge
Wireless detector + Free to share
3、MobiEye700 competitor analysis
Shimadzu
Siemens
Carestream
Sedecal
IMD
Browiner
Perlong

30 © 2011 Mindray Confidential


3、MobiEye700 competitor analysis

31 © 2011 Mindray Confidential


3、MobiEye700 competitor analysis
 Mindray VS Carestream

VS

32 © 2011 Mindray Confidential


3、MobiEye700 competitor analysis
 Mindray VS Carestream
Parameter MobiEye700 DRX- State
Revolution
Power 30/50kw 32kw 30kW or upon can meet each parts radiography

Inverter 460kHz 100kHz Higher inverter frequency , lower radiation dose


frequency
Weight ≤400kg ≥550kg Light weight, low energy consumption

Climbing angel 12° 7° Better move performance to adapt to the hospital


complex terrain
Body width 550mm 576mm Little body and better through performance

Focus to the Maximum Maximum 2300mm SID ensure adequate recumbent chest
floor 2300mm 2020mm radiography
Detector online Have Battery The detector directly charge ,no need to take out the
charge charge battery of the detector to charge
Remote control RF IR RF remote control is not afraid of blocking, distance
farther
Battery 70km or 700 3.2km and Strong endurance , ensure continuous working power
performance times 120 times

33 © 2011 Mindray Confidential


3、MobiEye700 competitor analysis
Shimadzu

Product model MobiEye700 DRX-Revolution Mobile DaRt-evolution Optima XR220amx Mobile Diagnost wDR Mobilett Mira

Weight 380kg 575kg 394kg 380kg 500kg 285kg

Stand column height 1780mm 1220mm 1800mm 1930mm 1970mm /

Length (no handle) 1100mm 1030mm 1140mm 1100mm 1150mm 1030mm

Width 550mm 576mm 580mm 540mm 678mm 550mm

Body width 470mm 576mm 550mm 540mm 618mm 550mm

Sway arm structural style


Articulated type Electric Telescopic Telescopic Telescopic Telescopic Articulated type
(coverage area)

Monitor size 19 inch 19 inch 15 inch 15 inch 17 inch 15 inch

Detector configuration Wireless/wired wireless wired Wireless/wired Wireless Wireless

High voltage wire manager 3/4 hide exposed exposed exposed Half hidden Hide

Movement mode Motor-driven/Manual Motor-driven Motor-driven Motor-driven Motor-driven Motor-driven

Detector lock control Have / / / / /

Power 30/50kw 32kw 12.5/16kw 15kw/30kw 20/40kw 30kw

Power supply mode Battery / AC Battery Battery Battery Battery Battery / AC

Remote control RF remote control IR remote control IR remote control IR remote control IR remote control IR remote control

Radar early warning Have / / / / /

Lamplight early warning Have / / / / /

34 © 2011 Mindray Confidential


MobiEye700 Overview—Q&A
1. How many MobiEye700 types and the differences of them?
MobiEye700 MobiEye700A
2. How many types of X-ray tube which the MobiEye700 can be optional and the differences of
the tube parameter?
Toshiba(30kw), IAE(50kw, anode heat capacity: 300kHU)
3. How many kinds of detectors that the MobiEye700 can be optional and the differences of the
detector parameter?
Mindray (wired / wireless), Toshiba (wireless)
4. What are the optional accessories for MobiEye700 ?
Stand column,patient table,DAP,AEC,detector handle,grid,portable workstation,scanner
5. What's the dual mode exposure? What's the compartment exposure?
Both AC supply and the battery supply to make exposure;can use for the stationary DR.
6. How to switch the manual mode and the automatic mode?
On the big wheel flange, M: manual A: automatic

35 © 2011 Mindray Confidential


Contact us:
Benson
Radiography product global technical support department
Technical support engineer
E-mail:benson.wu@mindray.com
Website: www.mindray.com

36 © 2011 Mindray Confidential


Version information
SN Writer Date Description
1.0 Benson 2016-6-6 DigiEye700 Training Material
2.0 Benson 2019-7-17 Upgrade

37 © 2011 Mindray Confidential


Check situation
SN Checker Checking date Change point
1.0 Alfred 2016-6-6 N/A
2.0 Alfred 2019-7-14 N/A

38 © 2011 Mindray Confidential


Thanks!

39 © 2011 Mindray Confidential

You might also like