Why DWDM: DWDM permitts rapid N/w deployment and significant N/w cost reduction. Use of DWDM allows
deployment of less fiber and hardware with more bandwidth.
DWDM systems allow many discrete transport channels to be carried over a single fiber pair.
Nine discrete channels share the fiber pair with an aggregate bandwidth of 90 Gb/s.
1830 pss 16: Used as a repeater site. 2 Amplifier cards on slot 3 & 4. Amplifier card contain below code:
Line port, Signal port, DCM Port.
Line port: Each 100 km we install repeater site. OSP fiber drop at line port through ODF (TX-RX).Pss-16 is line ODF
bcz it’s a repeater site. Usually used on Highways.
1830 pss 32: Amplifier card is install on slot 2 & 17 (line port). Slot 2 (signal port) contain DCN signal port. Any SFP
is installed e.g; 40GB, 10GB, 4GB,……. Mostly used for 10G SFP. PSS32 is client & line ODF.
11*1: Single tuneable any data rate. 1 is the client port
11 DPM 12: Dual plug multirate. 12 is the client port.
1830 pss 36: Also known as OTN. 100GB data is transmitted.
SFP (Small form factor plugable): Multimode & Single mode. SFP is a fiber optic transceiver.
For Multimode fiber the SFP module is called SX for short distance & Freq; is 850nm & for Single mode fiber the
SFP module is called LX (Long Haul)for long distance Freq: is 1310nm (LX: Long hole).
Conventional TDM & DWDM Transmission syster-----10GBps:
In TDM transmission if we have 4 fiber pairs, After 40Km of each we need 32 Regenarators.while in DWDM
transmission for one fiber pair we need 4 Optical Amplifiers n 120KMs.
ADM-1660: PDH supported & capacity is 10GB.(Receive & drop). Used as Amplifier for long distance.
Total Slots: 41.(for Cards).
Slots 1-5: pdh supported. & slot # 22(we can login) Eque card.(PQ2 & EQC card)
Slot 23: (Active)Matrix card. For supervision and cross connection.
Slot 40(Standby) Matrix card.
Slot 28,34,38: CO64 Card. (long SFP Module)
Slot 28, 39: Iza card (Iza IS4, & IZA IS16) for 3G traffic.
Slot 11: Service cards.
Slot 10, 12: Congi Car.
2 FAN units are down installed. DC power is 63 Amp.
ADM-1662: Also PDH supported & capacity is 2.5 GB(Mostly used in city) for short distance. Total Slots:
20 (for cards).
Slot 1-3: PDH supported. & Slot 6 & 15 (Active & Standby)Synthx 16. We login through slot 16.
Slot 9: Congi card. (for alarms indications)
Slot 10: Service cards
2 FAN units are down installed. DC power is 32 Amp.
ADM-1678: Only SDH supported & capacity is 40 G. (Main Backbone). Total Slots: 20 (for cards).
Slot 1-20: Flc Service cards. From slot 1 we login.
Slot 10-11: Matrix cards. (for cross connection) 3g data monitoring.
2 FAN units are installed up & down DC power is 80/100 Amp.
TOTAL ALARMS:
(LOS) Low power received
(RUP) Replacement unit problem. When card is faulty
(DS) Degrated Signal. Even power is received but packets and frames are droped. Alarm clear when we
hard reset or clean the fiber.
(RUM) Replace unit missing or Mismatch. Alarm occurred when SFP wrong part # is installed.
(RDI) Remote detect indication. Far end Alarm
(URU) Underline resource unavailable. When both matrix cards are faulty.
(ILM) Internal link monitor. Mostly when internal communication disturb b/w the cards. Occurred due to
matrix, synthex card.
For Software Up gradation: Usually flash is installed in EQ2 & Synthex cars. We find flash mostly in 1660
& 1662. In 1678 Hard drive (20GB) is installed installed for backup.
ANALYZERS (XFO, BIRD (T-BIRD 6000 & 8000, JDSU-with many types.<JDSU-2872 is Ethernet
Analyzer.
Test through Analyzers: Throughput test, Latency test, Ping test, Ring Test.
Latency: Means for a Packet of data, how much time it takes to get from one designated point to another.
Ideally latency is as closed to zero as possible.
In transmission the Optical Fiber itself introduces some delay, which varies from one medium to another.
Throughput test: In data transmission, throughput is the amount of data moved successfully from one
place to another in a given time period .
2. SNCP (Sub N/w configuration Protection): SNCP is better than MSP due to less
switching time, But has less capacity. (Total Capacity is STM-N)
Flash Card Used in Alcatel ADM: It has the configuration of NODE & Software. Without a
flash card we can’t do any configuration or connect to NODE.
Removal of Flash Card don’t effect the Traffic on NODE.