MasterBrace® LAM (Formerly known as Mbrace ® Laminate)

High Strength and High Modulus Unidirectional Pultruded Carbon Fiber Laminates

DESCRIPTION OF PRODUCT strengthening works can be done with


temporary stops
MasterBrace® LAM is high strength or high ● Decreases the bending deformations in the
modulus unidirectional pultruded carbon fiber slabs and beams
laminates in MasterBrace® FRP System.
APLICATION PROCEDURE
FIELDS OF APPLICATION
Preparation of Substrate
● Increasing the flexural strength of the concrete
beams The mineral based substrates (concrete, stone,
● Increasing the flexural strength of the concrete brick, tile etc.) must be sound, clean and dry. It
slabs under heavy machine loads shouldn’t be weakened by over-troweling and
● Increasing the rigidity of the beams and slabs lack of curing. The concrete should be free of
against bending deformations frost, curing membranes, waterproofing
● Increasing the flexural strength of the concrete
treatments, oil stains, laitance, friable material
slabs damaged with ventilating channel and dust. If there is a water leakage it must be
openings, stairs and elevator holes etc. drained or properly plugged. In case of low
● Increasing the flexural strength of the concrete
strength concrete ( tc <1.5 N/mm2), the loosen
beams and slabs under increased service loads parts of concrete must be broken and the
(change of usage etc.) surfaces should be reprofilled with structural
repair mortars in MasterEmaco® S range.
● Decreasing disturbing effect of the vibrations
Before the adhesive application let the repair
on the slabs caused be machines
mortars cure at least 7 days at 20oC. FRP sheets
should be free of oil stains and dust. In all kind
FEATURES AND BENEFITS
of substrates MasterBrace® P 3500 should be
used as a primer and the adhesive application
● Light and easy to carry should be done in the following 24 hours.
● East to cut and re-shaped
● Easy to design (Unidirectional laminates and APPLICATION METHOD
similar elasticity modulus with steel)
● Does not increase the gravity of the structure MasterBrace® ADH 4000 should be applied to
● Does not requires to empty the structure and the prepared surfaces and to FRP laminates by
MasterBrace® LAM (Formerly known as Mbrace ® Laminate)

High Strength and High Modulus Unidirectional Pultruded Carbon Fiber Laminates

using a steel spatula or steel trowel. Application HEALTH AND SAFETY PRECAUTIONS
thickness should be between 1.0-2.0 mm. In the
following 10 minutes (at 25oC) FRP laminates It is dangerous to approach the application sites. During
should be placed on to the substrate and push the application, a protective apparel, protective gloves,
on to the laminates with a stiff roller (polyamide, goggles and masks which comply with the Occupational
steel etc.) for preventing possible air gaps Health and Safety Rules should be used. Due to the
between the laminate and substrate. For irritation effect of the uncured materials, the mixture
plastering on the fiber surface, clean and sound should not come into contact with skin and eyes; in
sand should be spread on to the fiber surface case of a contact, the affected area should be washed
while the adhesive is still wet. After curing of with plenty of water and soap; in case of swallowing,
adhesive any kind of plaster can be easily a physician should be consulted immediately. No food
applied. For fire resistance, the fibers should be or beverages should be brought to the application
coated with special fire resistant coatings area. The product should be stored and kept out of
(Meyco® Fireshield, etc.). reach of children. For detailed information please
consult the Material Safety Data Sheet.
WATCH POINTS
DISCLAIMER
● MasterBrace® FRP applications should be
done by approved experts. The technical information given in this publication is
● Work clothes, protective gloves, glasses and
based on the present state of our best scientific and
mask defined in Labour Laws must be used practical knowledge. BASF Türk Kimya Sanayi ve
during the application. Do not touch to the Tic. Ltd. Şti. is only responsible for the quality of the
fibers without hand gloves. product. BASF Türk Kimya Sanayi ve Tic. Ltd. Şti.
● Consult to the BASF Türk Kimya Sanayi ve
is not responsible for results that may occur because
Tic. Ltd. Şti. Technicians for special the product is used other than advised and/or out of
applications aren’t defined in this data sheet. instructions regarding the place and the method of
use. This technical form is valid only till a new version
CLEANING OF TOOLS is implemented and nullifies the old ones.

After the application all tools should be cleaned Contact Information


with a proper detergent or solvent such as
thinner. BASF Türk Kimya San. ve Tic. Ltd. Şti.
Yapı Kimyasalları Bölümü
PACKAGING Tel: 0216 570 34 00
Fax: 0216 570 37 79
100 m rolls Mail: info@master-builders-solutions-turkey.com
www.master-builders-solutions.basf.com.tr
STORAGE
® = Registered trademark of the BASF-Group in many
Store in original container in cool (+5oC-+30oC) countries of the world
and dry indoor conditions. MasterBrace LAM Technical Data Sheet - Issue Date: