LT-80200 7-19

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Configuración del dispositivo

Etiqueta: LT-80200
Tipo de dispositivo: 3051
Fabricante: Rosemount
116 Variables

Impreso el: 17/07/2019 9:14:30

Parámetro Valor Parámetro Valor


(9091:Variable) * Manufacturer Rosemount
Alarm/Sat Type Std Message
Alert Mode Off Meter type Alt % rnge|Eng unit
Analog Output Valor incorrecto Minimum Span 58
AO Alrm typ Valor incorrecto Model 3051
Burst mode Off Model Number 1 3051S2LD2AA1A10...
Burst option ***** Model Number 2 1199MAB05AFFWG...
Calibration Type Diff (DP) Model Number 3
CM Lower Value 0.0000 Module Temperature 22.4
CM Units DEFLT Num req preams 5
CM Upper Value 1.0000 Num resp preams *****
CM xf fnct Linear Number Two seal
CMV -0.1070 Offset 0
Communication statu... 0x00 O-Ring Material PTFE
Configuration Std coplanar (C) Percent of Range Valor incorrecto
Cutoff Mode Off Physicl signl code Bell 202 current
Date 03/23/2008 Poll addr 0
Descriptor ANALOG INPUT CH... Press Alert Installd
Dev flags 0x00 Pressure -680
Dev id 3704806 Pressure Damping 0.40
Device status 0x00 Pressure Input 1 0
Diaphragm Material 316 SST Pressure Input 2 6350
Direction High Process Connection Spcl
Distributor Rosemount Process Connection ... 316 SST
Drain Vent Material 316 SST PV % rnge 1.193
Fact trm recal loc ***** PV is Pressure
Fill Fluid Silicone oil PV LRV Valor incorrecto
Fill Fluid Spcl PV URV Valor incorrecto
Final asmbly num 2410227 Response code Success
Fld dev rev 7 scaled available Installd
Hardware rev 16 Scaled Output 1 0.000000
High Alarm 22.10 Scaled Output 2 1.000000
High Alarm 22.10 Scaled Variable -0.10708
High Alert Value 6350 Select dec pt pos 4
High Alert Value 85.0 Sensor Range 2
High Sat 20.80 Sensor Serial Numb... 3704806
High Saturation 20.80 Software rev 7
Isolator Material 316 SST Status group 0 0x00
Local ZERO / SPAN ... Enable Status group 1 0x00
Loop current 4.191 Status group 2 0x00
Low Alarm 3.73 Status group 3 0x00
Low Alarm 3.73 Status group 4 0x00
Low Alert Value -6350 SV index used 1
Low Alert Value -40.0 SV is Sensor Temperature
Low Flow Cutoff 0.00000 SV max index 1
Low Sat 3.90 SV Units DEFLT
Low Saturation 3.90 SV Units *DEFLT
Lower 0 Tag LT-80200
Lower Sensor Limit -6350 Temp Alert Installd
LRV -687 Temp available Installd

1
Parámetro Valor
Temperature Proces... Off
Temperature Units degC
Transfer Function Linear
TV is Scaled Variable
Type FFW
Type Diff (DP)
Unit mmH2O
Units of Measure *DEFLT
Universal rev 5
Upper 6350
Upper Sensor Limit 6350
URV -95
Variable(s) 0x03
Write protect No
Xfer fnctn Linear
Xfer fnctn Valor incorrecto