Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 8

Disclaimer

Our policy is one of continuous development. Accordingly the design of our products may change at any time.
Whilst every effort is made to produce up to date literature, this document should only be regarded as a guide and is
intended for information purposes only.
Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. We cannot
be held responsible for any reliance on any decisions taken on its contents without specific advice.

Page 1 of 8 531938034.xls 07/13/2021


CORTEC

Ordering information

Variants Order No.


MVAJ - High/Low Burden Tripping Relay MVAJ
Number of Contacts
Five 0 5
Ten 1 0
Twenty 2 0

Contact Mechanism
Self Reset (5 & 10 Contacts Only!) 1
Self Reset (Delayed 2s) (10 Contacts Only!) 2
Hand-Reset 3
Electrically-Reset 4
Hand & Electrically-Reset 5

Case
Size 2 (5 & 10 Contacts Only!) - Blue/Grey livery J
Size 4 (20 Contacts Only!) - Blue/Grey livery L
Size 2 (5 & 10 Contacts Only!) - Grey/Grey livery R
Size 4 (20 Contacts Only!) - Grey/Grey livery T

Flagging
Standard Hand - Reset Flag A
Following Flag B

Voltage (Nominal)
24/27 Volts 0 0
30/34 Volts 0 2
48/54 Volts 0 5
110/125 Volts 0 8
220/250 Volts 1 0

Contact Combinations
5 Contact Versions
5 Normally Open 0 0
4 Normally Open/ 1 Normally Closed 0 1
3 Normally Open/ 2 Normally Closed 0 2
2 Normally Open/ 3 Normally Closed 0 3
4 Normally Open/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!) 9 1
2 Normally Open/ 2 Normally Closed/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!) 9 2
1 Normally Open/ 3 Normally Closed/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!) 9 3
3 Normally Open/ 1 Normally Closed/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!) 9 4
10 Contact Versions
10 Normally Open 0 0
8 Normally Open/ 2 Normally Closed 0 2
6 Normally Open/ 4 Normally Closed (MVAJ101R*08** variants OR MVAJ103/4/5 ONLY!) 0 4
4 Normally Open/ 6 Normally Closed (MVAJ101R*08** variants OR MVAJ103/4/5 ONLY!) 0 6
2 Normally Open/ 8 Normally Closed ( Not MVAJ101/2 !) 0 8
20 Contact Versions
20 Normally Open 0 0
18 Normally Open/ 2 Normally Closed 0 2
16 Normally Open/ 4 Normally Closed 0 4
14 Normally Open/ 6 Normally Closed 0 6
12 Normally Open/ 8 Normally Closed 0 8
10 Normally Open/ 10 Normally Closed 1 0
8 Normally Open/ 12 Normally Closed 1 2
6 Normally Open/ 14 Normally Closed 1 4
4 Normally Open/ 16 Normally Closed 1 6

Issue
Factory Defined *

Page 2 of 8 531938034.xls 07/13/2021


Configurator

MVAJ Tripping Relay High or Low Burden


To enable only current variants to be offered, please specify ACTUAL or REQUIRED delivery date here
Format = dd/mm/yy (where d=day, m=month, y=year)
Digit No 1-4 5-6 7 8 9 10 - 11 12 - 13 14

PCS VARIANT MVAJ 20 5 T A 08 06 A


TRIPPING RELAY
HIGH BURDEN
Number of Contacts
Select ONE of ...
Five 20
Ten
Twenty
Contact Mechanism
& Reset Time Delay
Select ONE of ...
Hand - Reset
Electrically - Reset 5
Hand & Electrically - Reset

Case (Dependant on number of contacts)


Size 4 - Flush T
Flagging
Select ONE of ...
Standard Hand - Reset Flag A
Following Flag
Nominal Supply Voltage
Select ONE of ...
24/27 Volts
30/34 Volts 08
48/54 Volts
110/125 Volts
220/250Contact
Output Volts Configuration
Select - Normally Closed
Select ONE of …
0 - Normally Closed
2 - Normally Closed
4 - Normally Closed
6 - Normally Closed 06
8 - Normally Closed
10 - Normally Closed
12 - Normally Closed
14 - Normally Closed
Calculated - Normally Open
16 - Normally Closed
14 - Normally Open
Issue A

Page 3 of 8 531938034.xls 07/13/2021


Master Text

MASTER TEXT
MVAJ205TA0806A
MVAJ - High/Low Burden Tripping Relay
Nominal Supply Voltage :
110/125 Volts
Contact Mechanism :
Hand & Electrically - Reset
Contact Configuration :
14-Make, 6-Break
Flagging :
Standard Hand - Reset Flag
Special Instructions :
After test external link(s) MUST be fitted between case terminals 22 & 24 and 21 & 23 as detailed in the test
instructions.

DOCUMENTS

Wiring/Circuit Diagram :
01MVAJ20501 SHT 1
Customer Diagram :
01MVAJ20501 SHT 1
Wiring Schedule :
02MVAJ20501 SHT 1
Outline Wrapper :
GJ0025 SHT 3
Test Specification :

Page 4 of 8 531938034.xls 07/13/2021


BOM

PCS MATERIAL Qty.


NUMBER DESCRIPTION
MASTER Required
MVAJ205TA0806A
Aux Unit 1 FB0307041.14 AUX(ZC0419004) 5B 7M 1
Aux Unit
Coil
Contacts

Page 5 of 8 531938034.xls 07/13/2021


Routing

Model No: MVAJ205TA0806A


Ref Op Set: 50000154
Add Pre-production Ref. Op. Set 50000021
Add Inspection Characterisitics Op. 9000, 4

Delete operations 30 to 42 inclusive


Delete operations 60 to 73 & 75 inclusive
Delete operations 90 & 91

43 105BA Assemble & Wire 68.4 Mins


50 105BB Product Check - Assy & Wire - Unit 5 Mins
74 105BC Prep for Test 10.3 Mins
80 105BC Customer Special Labels 0.6 Mins
85 105BB Product Check - Case,Cover & Labels 1 Mins
92 105DB Auto Test 4.9 Mins
1000 105BQ Final Inspection 3 Mins
9000 105BP Primary Packing 6.5 Mins

Page 1 of 1 531938034.xlsRouting 07/13/2021


Aux Unit FB0307041
Coil ZC0419004
Contacts FB0317073

New Aux Unit.Suffix (If Req'd)->

Copy From -------------->


D
D
06

FB0307041.

FB0307041.

You might also like