TC-09U Test Report - HSD
Panel preparation
All testing was undertaken in-house using Instron 33R frame test / 50kN load cell / Bluehill 2 software
Test results
0°
Property Units Test method Dry
Mean
Flexural strength Mpa ASTM D790 1383,5
Flexural modulus Gpa 141,0
Tensile strength Mpa ASTM D3039 2110,0
Tensile modulus Gpa 168,6
Compressive ASTM D695
Mpa 367,4
strength 02A
Compressive
Gpa 90,9
modulus
These property values were generated by JB Martin Ltée Test results may vary depending on how closely the
manufacturing and testing protocols correspond to those specified It is the responsibility of the customer to
ensure that J. B. Martin and Martintek materials are suitable for the particular purpose and use intended by the
customer.
Date: April 20, 2012