Shearfi X Punching Shear Reinforcement: For The Construction Industry
Shearfi X Punching Shear Reinforcement: For The Construction Industry
Shearfi X Punching Shear Reinforcement: For The Construction Industry
October 2018
Shearfix Punching
Shear Reinforcement
for the Construction Industry
Punching Shear Reinforcement
Reinforcing Concrete Slabs at Column Heads
The weight of a slab supported beams and enlarged column
on a column induces shear heads, the construction of flat
stresses in the slab. These slabs offers many advantages.
stresses, if sufficient and where A consistent head space can
additional reinforcement has not reduce the overall height of a
been provided, would result in building and provide significant
the column ‘punching’ through time and material savings.
the slab. This punching shear is Used within a slab to provide
similarly induced in the footing additional reinforcement around
on which the column bears. columns, Ancon Shearfix is
the ideal solution to the design
and construction problems
associated with punching shear.
The system consists of double-
headed studs welded to flat rails,
positioned around the column
head or base. The shear load
Although punching shear can be from the slab is transferred
relieved by localised thickening through the studs into the
of the concrete with downstand column.
Contents
Ancon Shearfix 4 Design Program 8
Comparison with Shear Links 4 Typical Rail Arrangements 10
System Components 5 Installation Procedure 10
Design Information: Applications 11
BS EN 1992 (Eurocode 2) 6
Other Ancon Products 11
Large and Elongated Columns 7
3
Shearfix Punching Shear Reinforcement
Ancon Shearfix
Used within a slab to provide additional reinforcement around columns, Ancon Shearfix is the ideal
solution to the design and construction problems associated with punching shear.
The system consists of double-headed studs welded to flat rails, positioned around the column head
or base. The shear load from the slab is transferred through the studs into the column.
Shearfix is suitable for all column shapes and is easy to install either ‘top down’ or ‘bottom up’,
depending on user preference.
Technical Approval Comparison with Shear Links Details for Specifying/Ordering
Shearfix has been evaluated by UK CARES for Ancon Shearfix offers many advantages Shearfix systems are designed to suit the
use in reinforced concrete slabs and footings over loose shear links. Links can be time- specific load conditions at individual columns
designed in accordance with BS EN 1992 consuming to both design and install. and are therefore manufactured to order.
(Eurocode 2). A Shearfix system is easily detailed with To specify and order an Ancon Shearfix
Ancon’s free calculation program which system, download the free design program
generates a layout drawing for inclusion in the at www.ancon.co.uk or contact Ancon for
building plans and, rather than being installed technical support.
individually, these studs are supplied to site The Ancon design program generates a 16
welded to rails at the appropriate spacing. digit reference code, which can be used to
When comparing links with studs, research specify/order Shearfix. Alternatively, should
has shown that any additional material costs you wish to manually specify each rail of studs
incurred when purchasing a prefabricated stud please use the following referencing system.
system, such as Shearfix, are generally far e.g AS12-3-150-180
outweighed by the savings from a significantly Where,
reduced fixing time; these systems being up AS = Shearfix Code
to ten times quicker to install (source: British 12 = Stud Diameter (mm)
Cement Association: Prefabricated punching shear
3 = Number of studs
reinforcement for reinforced concrete flat slabs. BCA,
150 = Stud length (mm)
Camberley, 2001).
180 = Stud spacing (mm)
Note: Rail supplied with end distance equivalent
to 0.5d (d = effective slab depth) where spacing
is 0.75d (0.6667xspacing). Other end distances
available upon request.
Corner column
5
Shearfix Punching Shear Reinforcement
0d
the outer control perimeter at which shear
2.
≤
reinforcement is no longer needed (uout) is then
d
calculated. Studs are arranged to start at 0.3d
.5
0.3-0.5d
≤1
1.5d
or 0.5d from the column face to within 1.5d of max
the outer control perimeter (uout); intermediate u0
2.0d 0.75d 0.75d 0.75d
studs are positioned at 0.75d centres. The
Ancon software defaults to a stud start point of
0.5d, although 0.3d is available as an option.
A radial layout will normally provide the
most cost-effective solution and rails can be
arranged with either 30º or 45º between them.
Cruciform rail layout is also an option. The
tangential spacing between studs is kept to
within 1.5d for studs within the basic control
perimeter (u1) and 2d for studs outside the
basic control perimeter; additional secondary
rails are added as necessary to comply with
this requirement.
Ineffective shear
For internal, edge and corner columns where perimeter
be ineffective and the perimeter lengths will
lateral stability does not depend on frame
be reduced. A series of rectangular or circular
action between slabs and columns, and where
openings can be added around each column
adjacent spans differ by less than 25%, the
using the Ancon design program which
recommended β values from BS EN 1992
then calculates the required punching shear Opening
can be applied to the design shear load
reinforcement.
VEd. However, β values are most accurately
determined on a case-by-case basis, taking Design Manual
the column location, geometry and loading An Ancon Shearfix manual to BS EN 1992
conditions into account. In the Ancon software, (EC2) is available. Contact Ancon for a copy.
by applying the moments, the program Design Sheet
calculates these β values automatically. In addition to the Shearfix design program
Alternatively, the β values can be calculated (see pages 8-9), a design sheet is available
manually and input directly into the program. to download from www.ancon.co.uk, which Any opening within 6d of column
face must be considered
Openings in the slab allows engineers to summarise the critical
Where there are openings in the slab within 6d details of their project and request technical
of the column face, a section of the slab will assistance with a Shearfix design.
U0 2.0d U1 1.5d max. Uout
Top cover Top reinforcement
Stud length
Slab depth
Stud
diameter
d
EC2
U1 U1
a1/2 a1/2 L1/2 L1/2
2d 2d
U0 U0
a
b D
L
a1/2 a1/2 L1/2 L1/2
Where: Where:
a1 = min(a,4b) L1 = min(L-D,3D)
u0 = 2a1 + 2b u0 = 2L1 + πD
u1 = 2a1 + 2b + 4πd u1 = 2L1 + π(D + 4d)
Best Practice
U1 U1
a1/2 a1/2 L1/2 L1/2
2d
2d
U0 U0
a
b1/2 b1/2 L
D
b
b1/2 b1/2
L1/2 L1/2
a1/2 a1/2
Where: Where:
a1 = min(a,4b,3d) L1 = min(L-D,3D,3d)
b1 = min(b,3d) u0 = 2L1 + πD
u0 = 2a1 + 2b1 u1 = 2L1 + π(D + 4d)
u1 = 2a1 + 2b1 + 4πd
There is no limit to the perimeter length effective in resisting punching shear of a circular column as a circular column has no ends or corners at which
the shear stresses could focus.
1 Einpaul, J., Bujnak, J., Fernandez Ruiz, M. and Muttoni, A. (2016). “Study on Influence of Column Size and Slab Slenderness on Punching
Strength” ACI Structural Journal, V. 113, No. 1, pp. 135-146
2 fib (2013). 7.3.5 Punching, Model Code for Concrete Structures 2010, pp.227-234
7
Shearfix Punching Shear Reinforcement
Column shape
Column location Rectangular Circular Oval
Internal 3 3 3
Edge 3 3 3
Corner 3 3 3
Re-entrant corner 3 3 7
Wall corner 3 7 7 The Ancon Shearfix Design Program contains
Wall end 3 7 7 a calculation management tool, allowing
multiple column locations to be designed Example of multiple openings
The program allows analysis to BS EN 1992 within a single project file. The calculations can
(Eurocode 2). be arranged in a system of sub-directories to
Where there are openings close to the column, ease project management. When exporting
a section of the slab will be ineffective and design information, any number of column
perimeters will need to be reduced; the Ancon locations can be included in a bulk export as
design program allows these reductions to be a PDF calculation report, a DXF file or a PDF
applied to each perimeter. parts list.
Screenshot of
an oval, internal
column with
a radial stud
layout
3D view in software
Screenshot of
a rectangular
column at a
re-entrant corner,
with a cruciform
stud layout
3D view in software
9
Shearfix Punching Shear Reinforcement
Cruciform Layouts
Installation Procedure
Ancon Shearfix is quick and simple to install.
It can be fitted either ‘top down’ (after all other
reinforcement) or ‘bottom up’ (prior to other
reinforcement).
‘Top Down’ Fixing
• Fix all main reinforcement in position
‘Top down’ fixing
• Place Shearfix rails around the column
to the layout detailed on job drawings
by passing the studs through the
reinforcement grid and resting the carrier
rails on the top layer of reinforcement.
Use spacer bars where required –
see page 5 for details
Special Fabrications
Ancon designs and manufactures high
Photo: Donal McCann
11
Masonry Support Systems
Lintels
Masonry Reinforcement
Windposts and Parapet Posts
Wall Ties and Restraint Fixings
Channel and Bolt Fixings
Tension and Compression Systems
Insulated Balcony Connectors
Shear Load Connectors
Punching Shear Reinforcement
Reinforcing Bar Couplers
Reinforcement Continuity Systems
Stainless Steel Fabrications
Flooring and Formed Sections
Refractory Fixings
Ancon (Middle East) FZE Ancon Building Products Ancon Building Products
PO Box 17225 2/19 Nuttall Drive GesmbH
Jebel Ali Hillsborough Puchgasse 1
Dubai Christchurch 8022 A-1220 Vienna
United Arab Emirates New Zealand Austria
Tel: +971 (0) 4 883 4346 Tel: +64 (0) 3 376 5205 Tel: +43 (0) 1 259 58 62-0
Fax: +971 (0) 4 883 4347 Fax: +64 (0) 3 376 5206 Fax: +43 (0) 1 259 58 62-40
Email: info@ancon.ae Email: info@ancon.co.nz Email: info@ancon.at
Visit: www.ancon.ae Visit: www.ancon.co.nz Visit: www.ancon.at
The construction applications and details provided in this literature are indicative only. In every case, project working
These products are available from: details should be entrusted to appropriately qualified and experienced persons.
Whilst every care has been exercised in the preparation of this document to ensure that any advice, recommendations or
information is accurate, no liability or responsibility of any kind is accepted in respect of Ancon.
With a policy of continuous product development Ancon reserves the right to modify product design and specification
without due notice.