Professional Documents
Culture Documents
FIR No. JSL-KAN-OGC-92091-FIR-015 Date. 26.06.2021
FIR No. JSL-KAN-OGC-92091-FIR-015 Date. 26.06.2021
FIR No. JSL-KAN-OGC-92091-FIR-015 Date. 26.06.2021
TABLE – 1: LOA Status (Cumulative Qty is accepted qty from Final Visual & Dimensional Inspection)
Ordered
Ordered Previous Today’s Cumulative Balance
Qty
Qty Qty Qty Qty Qty
Sr. combined %
Item Description
No. In Meters In Meters In Meters Completed
In In
(No's of (No's of (No's of In Meters
Meters Meters
Pipe) Pipe) Pipe)
48" Pipe, 20.6 mm WT, API 5L
*** 1 4200
Gr. X70MS / L485MS, PSL2, SAWL
26700 0.000 9289.235 9289.235 17410.765 34.79 %
48" Pipe, 20.6 mm WT, API 5L
*** 2 22500
Gr. X70MS / L485MS, PSL2, SAWL
48" Pipe, 23.8 mm WT, API 5L
*** 3 39000
Gr. X70MS / L485MS, PSL2, SAWL
48" Pipe, 23.8 mm WT, API 5L 39670 39723.305 0.000 39723.305 NIL 100.00 %
*** 4 300
Gr. X70MS / L485MS, PSL2, SAWL
48" Pipe, 23.8 mm WT, API 5L
*** 9 370
Gr. X70MS / L485MS, PSL2, SAWL
48" Pipe, 27.0 mm WT, API 5L
*** 5 60
Gr. X70MS / L485MS, PSL2, SAWL
338 376.230 0.000 376.230 NIL 100.00 %
48" Pipe, 27.0 mm WT, API 5L
*** 8 278
Gr. X70MS / L485MS, PSL2, SAWL
52" Pipe, 28.6 mm WT, API 5L
6 72 72 73.555 0.000 73.555 NIL 100.00 %
Gr. X70MS / L485MS, PSL2, SAWL
48" Pipe, 34.0 mm WT, API 5L
*** 7 36 36 60.725 0.000 60.725 NIL 100.00 %
Gr. X70MS / L485MS, PSL2, SAWL
16" Pipe, 10.0 mm WT, API 5L
*** 10 60 60 0.000 86.535 86.535 NIL 100.00%
Gr. X70MS / L485MS, PSL2, SAWL
*** - Total Completed % acceptable subject to test results of Mechanical test results of MPQT and RP.
Production Status - For Production status please see on Daily Production report.
For Regular Production Pipe Size: 16” OD X 10.0 MM WT & 48”OD x 20.60MM WT:-
Surveillance visual & dimensional inspection of incoming plats as per ITP Sr. No. 2.1 – Found within tolerance.
Random witnessed Calibration of Plate Ultrasonic testing as per ITP Sr.No.2.4 - Found satisfactory.
Random witnessed Plate Ultrasonic testing as per ITP Sr.No.2.4 - No significant defect observes.
Monitoring Edge milling as per ITP Sr.No.3.1 - Found satisfactory.
Monitoring Crimping of plates as per ITP Sr.No.3.2 - Found satisfactory.
Monitoring JCO forming as per ITP Sr.No. 3.3 - Found Satisfactory.
Monitoring welding consumable of wire, Flux & Electrode as per approved WPS and as per ITP Sr.No.4.2 - Found
Satisfactory.
Reviewed WPS & PQR for Process and Welder operator qualification as per ITP Sr.No.4.2 - Found in order.
Reviewed welding consumable of wire, Flux & Electrode MTC as per ITP Sr.No.4.2 - Found meeting the
requirements.
Monitoring Automatic tack welding as per ITP Sr.No. 4.3- Found satisfactory.
Monitoring Tab welding for GMAW welding as per ITP Sr.No. 4.4- Found satisfactory.
Monitoring Automatic submerged arc welding as per ITP Sr.No. 4.5 - Found satisfactory.
Monitoring preliminary visual inspection as per ITP Sr.No.4.6 - No injurious surface observed.
Monitoring straightness of pipe as per ITP Sr.No.6.0 - Found within acceptable limit.
Random witnessed Cold expansion as per ITP Sr.No.7.0 - Found satisfactory.
Random witnessed weekly Pressure gauge calibration as per ITP Sr.No. 8.0 - Found satisfactory.
Random witnessed hydrostatic test as per ITP Sr.No.8.0 - Neither pressure drop nor leakage observed during
holding time of 10 seconds minimum.
Random witnessed calibration of pipe for final automatic Ultrasonic testing as per ITP Sr.No. 9.1 - Found
satisfactory.
Random witnessed Final Automatic Ultrasonic testing as per ITP Sr.No. 9.1 - No significant defect observes.
Random witnessed calibration of MUT as per ITP Sr.No. 9.2 - Found satisfactory.
Random witnessed MUT untested weld length of 250mm mini. and AUT indication by angle probe as per ITP
Attending Inspectors: Kaushikkumar Patel & Mohit Solanki (Day Shift) & Ramdeo Yadav (Night Shift)
Category: (1) Accepted, (2) Conditionally Accepted, (3) Re-Inspection Required, (4) Rejected, (5) Advice / Instruction from Client Required.
Inspection Date(s):
ANY NON Yes
17/06/2021 to
CONFORMITY
25/06/2021
FOUND? No
Complete
Inspection Place(s):
ORDER
JCO – III, Jindal Saw Kaushikkumar Patel
STATUS
Ltd, Nanakapaya, Balance Supplier’s Signature & Date Date: 26.06.2021
Mundra Telephone No. Mobile No. +91-9687000073