Selection of Main & Branch Circuit Breaker For Distribution Box (As Per NEC)
Selection of Main & Branch Circuit Breaker For Distribution Box (As Per NEC)
Parmar
@yahoo.com
ress.com
Cable Detail
Max.Length Cable
(Meter) Selection
63 Not Proper 5 1 3
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
1 1Ph Lighting B Class I∆n:30ma Continious MCB 2
0 3Ph Heater B Class I∆n:30ma Non-Continious MCCB
0 Drive C Class I∆n:100ma Max.MCCB RCB
0 A.C C Class I∆n:30ma NEC ELCB
0 Motor C Class I∆n:100ma Total Amp RCCB
0 Ballast C Class I∆n:30ma
0 Ind.Load C Class I∆n:100ma
0 Transformer D Class I∆n:100ma
0 0
0 0
0 0
0 0
0 D Class
0 3
0 3 or 4
0 230
0 #N/A
0 I∆n:30ma
0 1
0
0.13 2
0.16 2
0.2 2
0.26 2
0.33 2
0.41 2
0.52 2
0.65 2
0.82 2
1.04 2
1.5 2
2.5 3
4 4
6 5
10 6
16 7
25 8
35 9
50 10
55 10
70 11
95 12
120 13
150 14
185 15
240 16
MCB / ELCB Selection Conversion
0 6 26 0.13
1 6 25 0.16
2 6 24 0.2
4 6 23 0.26
6 10 22 0.33
10 16 21 0.41
16 20 20 0.52
20 25 19 0.65
25 32 18 0.82
32 40 17 1.04
40 45 16 1.5
45 50 14 2.5
50 63 12 4
63 80 10 6
80 100 8 10
100 125 6 16
125 225 4 25
225 600 2 35
600 800 1 50
800 1600 0 55
1600 2000 0 70
2000 3000 0 95
3000 3200 0 120
3200 4000 0 150
4000 5000 0 185
5000 6000 0 240
6000 6000
As per GERC
Short Circuit
Voltage (Volt)
Current (KA)
4000000 40
220000 40
132000 32
66000 25
33000 32
11000 25
415 10
220 6
Maximum Circuit Length in mtr for Cu conductor ( for Alu
Operating Cuurent Im of the Instantaneous
1.5 2.5 4 6 10 16 25
Tripping element(A)
50 100 167 267 400
63 79 133 212 317
80 63 104 167 250 417
100 50 83 133 200 333
125 40 67 107 160 267 427
160 31 52 83 125 208 333
200 25 42 67 100 167 267 417
250 20 33 53 80 133 213 333
320 16 26 42 63 104 167 260
400 13 21 33 50 83 133 208
500 10 17 27 40 67 107 167
560 9 15 24 36 60 95 149
630 8 13 21 32 63 85 132
700 7 12 19 29 48 76 119
800 6 10 17 25 42 67 104
875 6 10 15 23 38 61 95
1000 5 8 13 20 33 53 83
1120 4 7 12 18 30 48 74
1250 4 7 11 16 27 43 67
1600 5 8 13 21 33 52
2000 4 7 10 17 27 42
2500 5 8 13 21 33
3200 4 6 11 17 26
4000 5 8 13 21
5000 4 7 11 17
6300 5 8 13
8000 4 7 10
10000 5 8
12500 4 7
conductor ( for Alu multiply 0.62)
467
365 495
292 396
233 317
208 283 417
185 251 370
167 226 333 452
146 198 292 396
133 181 267 362 457
117 158 233 317 400 435
104 141 208 283 357 388 459
94 127 187 253 320 348 411
73 99 146 198 250 272 321 400
58 79 117 158 200 217 257 320
47 63 93 127 160 174 206 256
36 49 73 99 125 136 161 200
29 40 58 79 100 109 128 160
23 32 47 63 80 87 103 128
19 25 37 50 63 69 82 102
16 20 29 40 50 54 64 80
12 16 23 32 40 43 51 64
9 13 19 25 32 35 41 51
Jignesh.Parmar
Calculate Size of Diesel Generator jiguparmar@yahoo.com
System Voltage ( P-P ) 415 Volt Linear Load: General Equipments, Heater www.electricalnotes.wordpress.com
Non-Linear
System Voltage ( P-N ) 230 Volt UPS,Invertor,Ballast,VFD
Load:
Future Load Expansion 10% % 1.1
Average Use of Equipment 0.8 (0.7 To 1.0) 0.8
Total Connected Load on Diesel Generator Set Starting Condition Running Condition
Load
Sr.N Starting Running Diversity Starting Starting Full Load Full Full Load
Equipment Load Type Supply Qty Motor Starter Starting Kw
o Load Kw/Hp P.F P.F Factor Amp Kva Kva Load Kw Amp :Calculation:
motor Motor 1Ph 1 10 Kw 0.7 0.8 0.8 Freq.Conv 52.2 13.7 9.6 10.0 8.0 43 Starting Kva 437 Kva
Motor 3Ph 1 120 Kw 0.7 0.8 0.8 Auto.Tra. 500.8 411.4 288.0 120.0 96.0 167 Starting Kw 307 Kw
Linear 1Ph 4 0.08 Kw 0.8 0.8 1 1.7 0.4 0.3 0.4 0.3 2 Starting Amp 603 Amp
Non-Linear 1Ph 2 3 Kw 0.8 0.8 0.8 41.7 9.6 7.7 6.0 4.8 26 Running Kva 137 Kva
Non-Linear 1Ph 2 0.5 Kw 0.8 0.8 0.8 7.0 1.6 1.3 1.0 0.8 4 Running Kw 110 Kw
0.0 0.0 0.0 0.0 0.0 0 Running Amp 243 Amp
0.0 0.0 0.0 0.0 0.0 0 Alternator Details
0.0 0.0 0.0 0.0 0.0 0 Voltage (P-N) 230 Volt
0.0 0.0 0.0 0.0 0.0 0 Efficiency 80%
0.0 0.0 0.0 0.0 0.0 0 Engine Overload Capacity 130% (Appro 130% To 150%)
0.0 0.0 0.0 0.0 0.0 0
0.0 0.0 0.0 0.0 0.0 0 :Required Size of Diesel Generator:
0.0 0.0 0.0 0.0 0.0 0 Diesel Generator Size 384 KVA (Select D.G near This Value)
0.0 0.0 0.0 0.0 0.0 0 Engine of Generator 114 KW
0.0 0.0 0.0 0.0 0.0 0
0.0 0.0 0.0 0.0 0.0 0
0.0 0.0 0.0 0.0 0.0 0 Calculate Efficiency & Unit Rate of Power of Calculate Approximate Fuel
0.0 0.0 0.0 0.0 0.0 0 D.G set Consumption
0.0 0.0 0.0 0.0 0.0 0 D.G Size ( Kva ) 412
0.0 0.0 0.0 0.0 0.0 0 D.G P.F 0.9 D.G Size (Kva) 412
0.0 0.0 0.0 0.0 0.0 0 D.G Running Hours 5 D.G P.F 0.9
0.0 0.0 0.0 0.0 0.0 0 Diesel Consumption (Liter) 1000 D.G Operation Full Load
0.0 0.0 0.0 0.0 0.0 0 KWH Reading of Meter 400
0.0 0.0 0.0 0.0 0.0 0 M.F of KWH Meter 1 Required Diesel
0.0 0.0 0.0 0.0 0.0 0 Diesel Rate /Liter (Rs) 54 Liter/Hour 95.1
0.0 0.0 0.0 0.0 0.0 0 Efficiency of D.G 22%
0.0 0.0 0.0 0.0 0.0 0 KWH/Liter (Unit Per Liter) 0.40
0.0 0.0 0.0 0.0 0.0 0 Unit Rate of Power (Rs) 135.0
0.0 0.0 0.0 0.0 0.0 0
Earth Resistivity Value Calculation
Reading Electrode Spacing Earth Tester Rading Earth Resistivity
Earth Pit No Date
No (S) (Meter) (Ω) (Ω-Meter)
1 1-Jan-10 1 0
2 2 0
Pit-1 3 5 0
4 10 0
5 15 0
1 1-Jan-10 1 0
2 2 0
Pit-2 3 5 0
4 10 0
5 15 0
1 1-Jan-10 1 0
2 2 0
Pit-3 3 5 0
4 10 0
5 15 0
1 1-Jan-10 1 0
2 2 0
Pit-4 3 5 0
4 10 0
5 15 0
1 1-Jan-10 1 0
2 2 0
Pit-5 3 5 0
4 10 0
5 15 0
1 1-Jan-10 1 0
2 2 0
Pit-6 3 5 0
4 10 0
5 15 0
Remarks
ss.com