JIS symbol list


1 Element of symbol (b) Functional element
(a) Symbol element
Name Symbol Applications Remarks
Name Symbol Applications Remarks
Equilateral Fluid energy
Line triangle direction
Continuous line (1) Main line Return line
Type of fluid
(2) Air supply line included Energy source
to pilot valve display
(3) Electric signals line Others: Indicate
the electrical Painted Hydraulics
symbol to identify
(1) Pilot operation from the piping White Compressed air and Including emission to
Broken line
line path other gas pressure atmosphere medium
(2) Drain line Internal pilot
(3) Filter External pilot
Arrow display (1) Linear movement
(4) Valve switching Straight or (2) Fluid flow path
position oblique line and direction
Dashed line Envelopment line Envelopment line in valve
indicating unit with
(3) Heat flow direction
more than one function
Double line Curve Rotary motion Arrow indicates the
Mechanical connection Rotary shaft,
rotational direction viewed
lever, piston rod,
from a free end of a shaft
etc.
Circle Oblique line Variable operation Draw oblique line with
Large circle Energy converter Pump, compressor, or adjustment method appropriate length
electric motor, etc. Such as pump,
spring or variable
Medium circle (1) Instrumentation solenoid
(2) Rotation joint
Other Electric
Small circle (1) Check valve Roller: Put a
(2) Link point on the
(3) Roller center.
Use the following symbols
Point when AC and DC
(1) Connection of line identification is required:
(2) Shaft of roller
Half circle Pump or actuator
whose turning
angle is limited
Closed path Port
Closed path or
Square (1) Fluid control The port closed port
components intersects
(2) Driving motor vertically with
other than the side. Solenoid
electric motor

Fluid adjustment The port Temperatureinstruction


components intersects with or adjustment
the corner.
Filter, drain Driving motor
(1) Cushion in separator,
cylinder lubricator, heat Refer to No. 7
(2) Weight in exchanger etc. Spring Two tops is
accumulator preferable
Rectangle (1) Cylinder Needle valve
(2) Valve

Mnemonic symbol
Piston of valve seat of
check valve

Specific operation
method Refer to No. 3 (a) (c) Mechanical element
Ending
Other Oil tank Name Symbol Remarks
Hollow type (large) (ventilation type)
Rod 2 direction operation
Arrow indication is optional
Hollow type (low) Local display of
Rotary shaft 2 direction operation
oil tank
Arrow indication is optional
(ventilation type)
(1) Oil tank Detent 2 direction operation
Capsule (closed type) Vertical line on notch
type (2) Pneumatics Latch indicates clamp
tank
1 direction operation
(3) Accumulator
(4) Auxiliary Symbol shows
gas vessel release method.

Ending 132
JIS

Name Symbol Remarks Name No. Symbol Remarks

Over center • 2 direction Lever 14 • 2 direction operation


mechanism operation (including rotary
motion)
2 Line and port Pedal 15 • 1 direction operation
(a) Line (including rotary
motion)
Name Symbol Remarks Double pedal 16 • 2 direction operation
Connection (including rotary
motion)

Mechanical control 20 • 1 direction operation


Cross • Not connected
plunger 21

Flexible line • Hose (normally


Variable stroke • 2 direction operation
connected to 22
movable portion) length limitter

(b) Connecting port


Spring 23 • 1 direction operation
Name Symbol Remarks

Air vent • Performing air vent


Roller 24 • 2 direction operation
continuously

Pull roller 25 • Arrow shows operation


• Performing air vent direction. Indication
in the specified may be omitted.
period, then closing. • 1 direction operation

• Performing air vent


by using check
Electrical control 30 • Solenoid, torque motor,
mechanism, if etc.
required. Direct electric
actuator 31 • 1 direction operation
Exhaust port • Pneumatics Single acting • The oblique line can slant
dedicated solenoid downward to the right.
• Without connecting
port Double acting • 2 direction operation
32
solenoid • The oblique line can
• With connecting
spread upward.
port

Quick joint • Without check


valve • 1 direction operation
Single-acting 33
variable solenoid • Proportional type
actuator solenoid
• With check valve
Double acting • Force motor etc.
(Self sealant joint) 34
variable solenoid • 2 direction operation
Connection state Removing state actuator • Torque motor
Rotary electric
35
Rotation joint • Swivel and rotary actuator • 2 direction operation
 joint • Electric motor
Indirect electric 36
actuator * JIS covers pilot operation, but
Single acting the valve is typically used as
1 line • 1 direction rotation
solenoid a solenoid valve, so the
transfer symbol (36) and (37)
3 lines Double acting 37
has been used for the electric
• 2 direction rotation
solenoid operation classification.

Pilot operation 40 Ending


Direct pilot
3 directional control valve operation
(a) Operation
41 • When different
Name No. Symbol Remarks pressurized areas, if
required, indicate the
Manual control 10 • General symbols when the
Internal pilot 43 number showing are ratio.
operation method is not indicated
or when the number of operation
• Operation flow path is
directions is not specified
provided in inside of
Pushbutton 11 • 1 direction operation    l
device.
  o
   b
Pull-button 12 • 1 direction operation External pilot 44
  m
• Operation flow path is   y
  s
provided out of device.
Push/pull button 13 • 2 direction operation    S
   I
   J

Ending 133
JIS

Name No. Symbol Remarks No. of Solenoid Status of normal


No. Symbol Remarks
port position position
Indirect pressure 4 2
control operation 4 3 P/A/B connection K
Pressurized
operation method
Pneumatics 42 • Internal pilot
1 3
pilot • No primary operation 4 2
5 3 P/A/B connection L
• Primary operation by
Electromagnetic, 36 single-acting solenoid
pneumatics • Internal pilot 5 1 3
pilot * The valve is typically
used as a solenoid valve, Note) Numerals indicate JISB8375 (ISO5599).
so transfer symbols in the (c) Manual control valve
30 s are used for transfer
symbols.
Name Combination symbol
   t    d
   r    m    e    m
Electromagnetic, 36 • Valve with manual    o    i   n   n    s    p    n    s
   p    o   o
    i
   o
   i    i
   t    n    t
    i
   y     i
   o
   t    n
Symbol
    f    n   t
pneumatics pilot override added to the Basic type and operator type    o    e    a
   i    r    a    a
   c    r
    h     i
   a
    h
 .    l   s   e   c    s    e   c
   o    o   o   p   e    a    p   e
with manual 10 above operation     N    S   p    O    m    B    O    m

override Direct acting normally closed 2 2 11 A 23


pushbutton and spring
(b) Directional control valve basic type • Return

No. of Status of normal


Position No. Symbol Remarks
port position Direct acting normally open 2 2 11 B 23
pushbutton and spring
2 2 Normally A Normally
• Return
closed closed

Direct acting normally closed 3 2 11 C 23


2 2 Normally B Normally pushbutton and spring
open open • Return

Direct acting normally open 3 2 11 D 23


3 2 Normally C pushbutton and spring
closed • Return

3 2 Normally D Direct acting normally closed 2 2 12 A 23


open pull-button, spring
• Return
4 2

4 2 P/B connection E Direct acting normally open 2 2 12 B 23


pull-button, spring
• Return
1 3

Note) Numerals indicate of JISB8375 (ISO5599).


Direct acting normally closed 3 2 12 C 23
4 2
pull-button, spring
P/B connection F • Return
5 2

Direct acting normally open 3 2 12 D 23


5 1 3
pull-button, spring
4 2 • Return

4 3 All ports closed G


Direct acting normally closed 2 2 13 A
push/pull button
1 3

4 2
Ending 13 B
Direct acting normally open 2 2
5 3 All ports closed H push/pull button

5 1 3

4 2 Direct acting normally closed 3 2 13 C

4 3 A/B/R connection push/pull button


I

1 3 Direct acting normally open 3 2 13 D


4 2 push/pull button
5 3 A/B/R connection J

5 1 3

Ending 134
JIS
Name Combination symbol Name Combinationsymbol
   t    t
   m    e    m    e
   n    n
   r    o    m    r    o    m
   o     i
    t
    i    n    s    p    n
    i    s
    i Symbol    o     i
    t
    i    n    s    p    n
    i    s
    i Symbol
   p    o
   s     i    y    o    p    s    o    y    o
   o    t   n    t     i    n    o     i
   t   n    t     i    n
Basic type and operator type     f    p    a    a    c    t
   a   a Basic type and operator type     f    p    a    a    c    t
   a    a
   o     f     h     i    r
   r     h    o     f     h     i    r
   r     h
 .    o    e    c    s    e   c  .    o    e    c    s    e    c
   o  .
   o    p    e    a    p   e    o  .
   o    p    e    a    p    e
    N     N    O    m    B    O   m     N     N    O    m    B    O    m

4 2
Direct acting normally closed 2 2 14 A 23 Direct acting both sides operation 4 2 11 E 11
lever, spring, pushbutton
return
1
4 2
Direct acting normally open 2 2 14 B 23 Direct acting both sides operation 5 2 11 F 11
lever, spring, pushbutton
return
1

Direct acting normally closed 3 2 14 C 23 Direct acting 4 2 13 E 4 2

lever, spring, push/pull button


return
1

4 2
Direct acting normally open 3 2 14 D 23 Direct acting 5 2 13 F
lever, spring, push/pull button
return
1

Direct acting lever 2 2 14 A 3 Direct acting closed center 4 3 14 G 3 4 2

with detent with lever and detent

4 2
Direct acting lever 3 2 14 C 3
(3) Item detent 1 (c) Direct acting closed center 5 3 14 H 3
with detent (4) Item latch 1 (c) with lever and detent
Generally, key selector
valve 1

Direct acting lever 2 2 14 A 4 Direct acting pedal 4 2 15 E 23 4 2

with latch spring and return


(foot valve)
1
4 2
Direct acting lever 3 2 14 C 4 Direct acting pedal 5 2 15 F 23
with latch spring and return
(foot valve)
1

Direct acting normally closed 2 2 15 A 23 Direct acting double pedal 4 2 16 E 4 2

pedal, spring, (foot valve)


return (foot valve)
1 3

Direct acting normally open 2 2 15 B 23 Direct acting double pedal 5 2 16 F 4 2

pedal, spring, (foot valve)


return
5 13

Direct acting normally closed 3 2 15 C 23 Direct acting double pedal 4 3 16 G 3 4 2

pedal all ports closed


with detent
1 3
4 2
Direct acting normally open 3 2 15 D 23 Direct acting double pedal 5 3 16 H 3
pedal all ports closed
with detent
5 1 3

Direct acting double pedal 2 2 16 A Note) Numerals indicate JISB8375 (ISO5599).


(foot valve for both foot)
Ending
(d) Mechanical control valve
Name Combinationsymbol
Direct acting double pedal 3 2 16 C    t
   r
   o
   n
   o
    i    n
   m    e
   s    p    n
   m
   p
    t
    i
   s    o
    i    y    i
   o
   s
    i Symbol
(foot valve for both foot) Basic type and operator type     f
   o
   o     i
   t   n
   p    a
   t
   a    c    t
   a
   n
   a
    f     h     i    r
   r     h
 .    o    e    c    s    e    c
   o  .
   o    p    e    a    p    e
    N     N    O    m    B    O    m

Direct acting pushbutton 4 2 11 E 23 4 2 Direct acting normally closed 2 2 21 A 23

spring and return plunger


spring and return
1
   l
Direct acting pushbutton 5 2 11 F 23
4 2
Direct acting normally open 2 2 21 B 23   o
   b
spring and return plunger   m
  y
spring and return   s
   S
   I
1
   J

Ending 135
JIS
Name Combination symbol Name Combination symbol
   t
   r
   n
   m    e    m    t    n
   e
   o    r    o    m    m
   o
    i
    t
    i    n    s
    i    p    n    s
    i    o
    i
    t    n    s
    i    p    n    s
    i
   p
    f
   o
   s     i
   o    t   n
   y    o
   t     i
   t   n Symbol    p
    i
   s    o
   o     i
   t   n
   y    o
   t     i
   t   n
Symbol
   a    a     f
Basic type and operator type    o
   p    a
    f    r
    h    i    a
   c    r    h Basic type and operator type    o
   p    a
    f    r
   a
    h    c    a    a
   i    r    h
 .    o    e    c    s    e   c  .    o    e    c    s    e   c
   o  .
   o    p
   e    a    p   e    o  .
   o    p    e    a    p   e
    N     N    O    m    B    O    m     N     N    O    m    B    O    m

Direct acting normally closed 3 2 21 C 23 Direct acting both sides pilot 2 2 41 A 41


plunger

Direct acting normally open 3 2 21 D 23 Direct acting both sides pilot 3 2 41 C 41


plunger

Direct acting normally closed 2 2 24 A 23 Direct acting pilot 4 2 41 E 23 4 2


roller spring and return
spring and return
1 3
Direct acting normally open 2 2 24 B 23 Direct acting pilot 5 2 41 F 23 4 2
roller spring and return
spring and return

5 1 3
Direct acting normally closed 3 2 24 C 23 Direct acting both sides pilot 4 2 41 E 41
4 2
roller
spring and return

1 3
Direct acting normally open 3 2 24 D 23 Direct acting both sides pilot 5 2 41 F 41
4 2
roller
spring and return

5 1 3
Direct acting normally closed 2 2 25 A 23 Direct acting all ports closed 4 3 41 G 41
4 2
single roller both sides pilot 23 23
spring and return spring and center

1 3
Direct acting normally open 2 2 25 B 23 Direct acting all ports closed 5 3 41 H 41
4 2
single roller both sides pilot 23 23
spring and return spring and center

5 1 3
4 2
Direct acting normally closed 3 2 25 C 23 Direct acting ABR connection
single roller both sides pilot
spring and return spring and center
1 3

4 2
Direct acting normally open 3 2 25 D 23 Direct acting both sides pilot
single roller A/B/R connection
spring and return spring and center
5 1 3
4 2
Direct acting P/A/B connection
(e) Pilot operated valve both sides pilot
spring and center
Name Combination symbol 1 3
   t    n
   e
4 2
   r    o    m    m
   o
    i
    t    n    s
    i    p    n    s
    i
   p
    i
   s    o
   o     i
   t   n
   y    o
   t     i
   t   n
Symbol Direct acting P/A/B connection
Basic type and operator type     f    p    a    a    a    a
   o     f    r
    h    c
   i    r    h
 .
   o
   o    e
 .
   o    p
   c
   e
   s    e   c
   a    p   e both sides pilot
    N     N    O    m    B    O    m
spring and center
5 1 3
Direct acting pilot 2 2 41 A 23
normally closed * The basic valve’s center
spring and return position operation symbol
can be written with a leader
line to the basic valve center
Ending
Direct acting pilot 2 2 41 B 23 position in the drawing.
normally open Example 4 2
spring and return

Direct acting pilot 3 2 41 C 23


1 3
normally closed
spring and return
Indirectly operation
Direct acting pilot 3 2 41 D 23 normally closed
normally open pilot spring
pilot and return

Note) Numerals indicate JISB8375 (ISO5599).

Ending 136
JIS
(f) Reverse not go shuttle and exhaust valve (g) Solenoid valve

Combination symbol Name Combination symbol


Symbol    t
   r    n    e
Name Operation Basic Operation (Details and simple symbol) No.    o
   o
    i
   t
   m
   n   i
   s    p
   m
   n   i
   s
Basic type and    p
    i
   s
   o
   o   n
   i
   t    a
  y
   t    o   n
   i
   t    a
Symbol
   f
mechanism type mechanism    o    p
    f    a   h
   r    c
   i    a   h
   r
operator type  .    o
 .    e   c    s    e   c
   o    o    p   e    a    p   e
   N     N    O    m    B    O    m
Check valve 43 A 43
without spring Direct acting normally 2 2 31 A 23
closed
single acting solenoid
spring and return
Simple symbol a

Direct acting normally 2 2 31 B 23


open
single acting solenoid
spring and return
Check valve 43 A 43
with spring 23

Direct acting normally 3 2 31 C 23


closed
Simple symbol a ' single acting solenoid

Direct acting normally 3 2 31 D 23


open
single acting solenoid
Pilot operation 41 A 43
check valve 43

Direct acting 2 2 31 A 31
both sides solenoid
Valve is closed by external b
pilot
Simple symbol

Direct acting 3 2 31 C 31
both sides solenoid

Direct acting 3 2 32 C
High pressure priority type 43 C 43 double acting solenoid
shuttle valve * Use this when the *
relationship to the
electric signal need * Position and functions of
not be indicated. valving element is specified.
Simple symbol c
Direct acting 4 2 31 E 23 4 2
single acting solenoid

1 3

Direct acting 5 2 31 F 23 4 2
Low pressure priority type single acting solenoid
shuttle valve

513
Indirect operation 4 2 36 E 23 4 2

single acting solenoid 43

The low pressure inlet is spring and return


connected to the low-pressure 1 3
priority output, and the high- * Pressure and
pressure inlet is closed. d return
Simple symbol Ending

Indirect operation 5 2 36 F 23 4 2

single acting solenoid


spring and return
5 1 3
Quick exhaust valve
* Pressure and * For the pressure and return
return operation symbol, indicate
the function element
triangle at the edge.

e Direct acting 4 2 31 E 31 4 2    l


Simple symbol   o
both sides solenoid    b
  m
  y
  s
1 3
   S
   I
   J
Note) Numerals indicate JISB8375 (ISO5599).

Ending 137
JIS

Name Combination symbol Name Combination symbol


   t    n    e    t
   r    o
    i    m    p    m    m    e    m    n
   o    r
   o    t    n   s    n   s    n   s    p    n   s     i
   t    o
Basic type and    p
    i
   s    o   i
   i    y
   t    o   i
   i Symbol Basic type and    o   i
   i    y
   t    o   i
   i
   t    n
    i
   s    p Symbol
   f    o    t   n    t   n    t   n    o    f
   o    p    a    a    c
   i    a    a    a    c
   a   h    a   a
   r    h    p
   o
    f    r   h    r   h    r    i     f
operator type  .    o
 .    e   c    s    e   c operator type    e   c    s    e   c
   p   e
   o
 .
 .
   o    o    p   e    a    p   e    p   e    a    o    o
   N     N    O    m    B    O    m    O    m    B    O    m     N    N

Direct acting 4 2 32 E 4 2 Direct acting PAB 5 3 31 L 31 4 2

double acting solenoid both sides solenoid 23 43 43 23


spring/pressure
centers used 513
1 3
together
* As stated above, JIS
stipulates that this is not
required if the relationship
to the electrical signal 4 2
need not be indicated. 32 Direct acting P/A/B 31 L 31
can be indicated as 31 - connection 10 10
both sides solenoid 23 43 43 23 *
-, which is the 513
abbreviation of 31 . with manual override
* If the diagram is
4 2 difficult to read when all
Direct acting 5 2 31 F 31
symbols are indicated
both sides solenoid on both ends, separate
symbols.
51 3
4 2
4 2
Direct acting 5 2 32 F Indirect operation 4 3 36 G 36
double acting solenoid all ports closed 23 23
both sides solenoid 1 3
51 3 spring/pressure centers
4 2
Indirect operation 4 2 36 E 36
both sides solenoid

1 3 4 2

4 2 Indirect operation 5 3 36 H 36
Indirect operation 4 2 37 E all ports closed 23 43 23
double acting solenoid both sides solenoid 513
spring/pressure
1 3
centers
4 2
Indirect operation 5 2 36 F 36
both sides solenoid

5 1 3

4 2
4 2
Indirect operation A/B/R 4 3 36 I 36
Indirect operation 5 2 37 F connection 23 43 43 23
double acting solenoid both sides solenoid
1 3
spring/pressure centers
5 1 3 used together
4 2
Direct acting all ports 4 3 31 G 31
block 23 23
both sides solenoid
spring/pressure centers 1 3 4 2
Indirect operation A/B/R 5 3 36 J 36
connection 23 43 43 23
4 2 both sides solenoid 5 1 3
Direct acting all ports 5 3 31 H 31
spring/pressure centers
block 23 23
used together
both sides solenoid
spring/pressure centers 5 1 3

4 2 4 2
Direct acting A/B/R connection 4 3 31 I 31 Indirect acting A/B/R 4 3 36 K 36
both sides solenoid 23 23 both sides solenoid 10 10
spring/pressure centers 23 23
Ending spring/pressure centers
1 3
1 3 pilot manual
override
4 2
Direct acting A/B/R connection 5 3 31 J 31
both sides solenoid 23 23
spring/pressure centers
5 1 3 4 2
Indirect acting A/B/R 5 3 36 L 36
both sides solenoid 10 10
4 2 23 23
spring/pressure centers 513
Direct acting P/A/B connection 4 3 31 K 31
with manual override
both sides solenoid
spring/pressure centers
1 3

Note) Numerals are indication of JISB8375 (ISO5599).

Ending 138
JIS
5 Speed control valve
Name Combination symbol
   t
   r
   o
   n
   o
    i    m
   n   i
   e
   p
   m
   n   i
Name Symbol Remarks
   t
    i    s    s Symbol
Basic type and    p    s    o   n
   i    y
   t    o   n
   i
   f    o    t    a    t    a
   p    a   h    a   h
operator type    o
 .
    f
   o
   r
   e   c
   c
   i
   s
   r
   e   c
Metering valve Details Simple • In simple symbols,
   o  .    p   e    a    p   e
   N
   o
    N    O    m    B    O    m Variable metering symbol symbol operation method and
valve valve's state are not
(Proportional control valve) 2 33 A 23
indicated
Direct acting • Normally, there is no
proportional electromagnetic completely closed status
flow control valve
Stop valve

Direct acting 3 33 C 23
proportional electromagnetic Speed control valve • With variable needle
flow control valve valve
• One direction is free
4 2 flow, while the other
(Servo valve) 4 34 G 23 direction is controlled
Direct acting 23 flow
electromagnetic servo control
spring/pressure center Metering valve
1 3

4 2
Metering valve
Direct acting 5 36 H 23 with silencer
electromagnetic servo control 23
spring/pressure
5 1 3
center

Note) Numerals are indication of JISB8375 (ISO5599).


6 Cylinder and motor
4 Pressure control valve
Name Symbol Remarks
Name Symbol Remarks
Single acting Details symbol Simple symbol • Extend type
Relief valve Direct acting or general
cylinder • Single rod type
Symbol
• Exhaust to
atmosphere

Pilot operation type


relief valve

Single acting (1) • Single rod type


cylinder (1) Rod extended by
Regulator Nonrelief type (with spring) spring force
(2) (2) Rod retracted by
spring force

Regulator with relief


Double acting (1) (1) Single rod type
cylinder (2) Double rod type

(2)
Pilot operation type regulator

Double acting
telescope type
Regulator with filter cylinder

Cylinder with Reference: Followed


adjustable stroke JISB8368 names.
In JISB01421984, the
(Head end)
Regulator with check valve head is on the cap Ending
side and the rod side
is on the head side.
Cylinder with
adjustable stroke
(Rod end)

Sequence valve

with speed • Example of meter-out


control valve
Proportional electromagnetic    l
  o
pressure control valve    b
  m
  y
  s
   S
   I
   J

Ending 139
JIS

Name Symbol Remarks Name Symbol Remarks

Tie rod cylinder • Describe the Driving motor (Excluding electric motor)
with brake braking method if
required.

Air tank

Cylinder with (1) * Symbol showing


end lock how to release
(1) Head end
8 Air adjustment component

Name Symbol Remarks


(2) Rod end
(2)
Note: Nominal values Filter (1) (1) General symbols
follow
JISB83681999.

(2) (2) With magnet


Cylinder • Specify a and b
with switch contact
(3) (3) With clogging
indicator

Filter (1) (1) Manual discharge


Non-rotating with drain discharger
cylinder
(2) Automatic
(2)
emission

Rodless cylinder (1) (1) Manual discharge


Oil mist separator

(2) Automatic
emission
(2)
Cylinder • Example of push type
with valve during energizing

Micro mist (1) (1) Manual discharge


separator

Air motor • 1 direction flow (2) Automatic


• 1 direction rotation (2)
emission
type

(3) (3) Deodorization


• 2 direction flow filter
• 2 direction rotation
type
Drain discharger (1) (1) Manual discharge

Oscillator • Pneumatics
• Constant angle (2) Automatic
• 2 direction oscillation type (2)
emission
• Drawings of arrows to
indicate relationship of
the shaft rotation Air dryer
Ending direction and flow
direction are optional.

Heat exchanger (1) (1) Water cooling type


7 Power and tank
Cooler (When not showing
Name Symbol Remarks water line)
Hydraulics (power) source • General symbols
(2) (2) Water cooling type
(When showing
water line)
Pneumatics (power) source • General symbols

Electric motor (3) (3) Air cooling type

Ending 140
JIS

Name Symbol Remarks Name Symbol Remarks

Lubricator All volume type Limit switch Can be indicated as follows


Selection type if drawing could not be misread:

Air ejector • Since Z 8207

Pneumatics Simple symbol The vertical arrow


adjustment unit indicates a discharger.

Pneumatics counter

Details symbol Details symbol


• Filter with manual
discharge valve
• Nonrelief type Pressure indicator • Simple indicator
regulator without measurement
• An example of direct
type lubricator is
indicated.

Oil mist separator Pressure gauge


for exhaust air

Noise reduction
device Differential pressure
gauge

Oil injector
Thermometer

Galvanoscope
9 Auxiliary components and other components
Name Symbol Remarks

Pneumatic - (1) (1) Single acting


hydraulic converter Flow meter

(2) (2) Continuous type

Integrated flow gauge


Booster (1) • When pressure ratio 1:2
• 2 class fluid
(1) Single acting

(2) Rotation speed gauge


(2) Continuous type

Booster valve Pressure ratio 1: 2

Torque gauge Ending

Delay valve (Example) • Indicate with a


compound symbol
based on the
mechanism
(Refer to JISB0125-1: 2001 and JPAS010.)
Alarm Note: mark is an original JPAS010 symbol.
Use is limited to those indicated.

   l
  o
   b
Pressure switch Can be indicated as follows   m
if drawing could not be misread:   y
  s
   S
   I
   J

Ending 141