Download as pdf or txt
Download as pdf or txt
You are on page 1of 144

GE Energy Connections GE Energy Connections

GE Energy Connections
121543
GuardEon*
with UL catalog
Since Thomas Edison patented the world’s first circuit breaker,
Industrial Solutions has been transforming the future of electrification.
We design electrical solutions at the crossroads of digital and industrial –
smart, rugged and equipped to control electricity from the grid to its point
of use. Every day, we partner with our customers to solve their toughest
energy challenges and reimagine industry in a way that only the world’s
digital industrial company can.

GuardEon - with UL catalog


GE
Industrial Solutions
41 Woodford Avenue
Plainville, CT 06062
1-800-431-7867

DET-886
* Trademark of General Electric Company
geindustrial.com © Copyright GE Industrial Solutions 2016 geindustrial.com
GuardEon

The circuit breaker Intro

Order codes A

Trip units B

Components and accessories C

Technical data D

Application guide E

Wiring diagrams F

Dimensions G

Numerical Index X

* Indicates a trademark of the General Electric Company. All other trademarks are the property of their respective owners. © 2016 General Electric Company. 1
GuardEon
GuardEon*

Intro

Common field-installable internal accessories across all sizes,


G
field replaceable and upgradeable thermal-magnetic and electronic
trip units (PremEon* S and PremEon G), and plug-and-play trip unit
X
advanced features are a few of the options that make…

2 * Indicates a trademark of the General Electric Company. All other trademarks are the property of their respective owners. © 2016 General Electric Company.
GuardEon

GuardEon family
Intro

B
With a current range from
Available in two sizes, 8A to 600A and 2, 3, and C
The GuardEon with GuardEon with UL 4 pole versions, these
UL family of global was designed with circuit breakers meet the D
molded-case circuit customers to requirements of UL, cUL,
breakers is designed meet a variety of IEC, CE, and CCC allowing E
to be simple, smart, applications from for a standardized
and secure. basic to advanced. global design. F

GuardEon with UL G

X
your choice for circuit breakers.

3
GuardEon

GuardEon circuit breakers are designed to protect, isolate, and switch


circuits in low voltage distribution networks. A combination of trip units
and the inherent current limiting properties of the circuit breaker
design allow for optimized circuit protection. Field interchangeable
and upgradeable trip units are available as either electromechanical

Key features
or electronic devices with sealable transparent trip unit covers.

E Frame
Rated up to 250A, the E Frame circuit breakers in
2, 3, and 4 pole design allow for easy connections
to busbar or cable lugs for copper or aluminum Intro
conductors. With field interchangeable and
upgradeable thermal-magnetic, magnetic-only, A
and PremEon S & PremEon G electronic trip units,
the E Frame allows for great application flexibility.
The double break contacts make the E Frame a B
very current limiting circuit breaker to help with
your selective, arc flash, and protection needs. C

G Frame E
Rated up to 600A, the G Frame circuit breakers in
2, 3, and 4 pole design allow for easy connections
to busbar or cable lugs with single or multiple
F
copper or aluminum conductors up to 750MCM
(380mm2). With field interchangeable and G
upgradeable PremEon S & PremEon G electronic
trip units, the G Frame can easily be adapted to
X
multiple levels of protection. The double break
contacts make the G Frame a very current limiting
circuit breaker to help with your selective needs.

5
GuardEon
Electromechanical devices
Devices available in a current range of 25A to 250A as 2, 3, or 4 pole configura-
tions. The electromechanical trip units can be thermal-magnetic, magnetic-
only, or generator protection models. The electromechanical trip units are
equipped with a fault indicator that distinguishes between overload and short-
circuit events in accordance with HD 384. This safety feature allows users to
reduce downtime by resetting the circuit breaker directly after an overload event.

Electronic devices
GuardEon E and G Frame sizes are all available with PremEon S or PremEon G
electronic trip units. With 2, 3, and 4 pole designs and current ranges from 8A to
600A, the PremEon trip unit family allows for great flexibility. The micro USB port
and free downloadable Trip Unit Toolkit software make external test kits obso-
lete. With no rating plugs, PremEon trip units offer maximum flexibility and
address coordination needs with settings established based on sensor rating
rather than the rating plug value.
GuardEon*

PremEon S
PremEon S an interchangeable and upgradeable electronic trip unit designed to
offer uncompromising reliability in all network environments in a current range
from 8A to 600A.
The first of the line, the PremEon S combines sophisticated 32-bit technology
with a built-in temperature sensor and a complete set of protection functions.
• An overload protection (LT) with a range of 0.2 to 1.0 times the chosen trip unit
rating
Intro • A delayed short circuit protection (ST) with wide setting range and I2T bands
• A selective instantaneous (I) that uses waveform recognition to assure selectivity
• An optimal ground fault protection device (residual principle) that can be used
with multiple delay and/or I2t settings
A
PremEon G
PremEon G is designed to provide a flexible solution for all protection scenarios
B in a current range from 8A to 600A. The device includes multiple protection
functions with adjustable settings to achieve the best possible protection and
response. Two options for metering are available, current only for basic meas-
urement or advanced metering for measurement of energy, harmonics, and
C more advanced characteristics. Field installable trip unit accessories adapt and
expand protection and measurement capabilities to suit the application.
Integrated test features and internal diagnostics monitor and communicate trip
D unit health.
All PremEon G trip units provide current metering while the Advanced Metering
option includes internal voltage sensors to add on-board energy and power
measurement. The Advanced Metering option also includes predictive mainte-
E nance features. On-board monitoring of contact wear and integrated timing of
the circuit breaker operating mechanism enable maintenance to be need based

Metering instead of calendar based.


• Metering with Class 1 (1.0%) current accuracy
F • Advanced Metering with Class 2 (2.0%) energy accuracy plus contact wear
and mechanism timing
…accuracy • Plug-and-play advanced features for Modbus RTU communications, Zone
G Selective Interlocking (ZSI), Reduced Energy Let-Through (RELT), and protective
relays
Plug-and-play • Overload protection (LT) settings in 1A increments from 0.2 to 1.0 times the
chosen trip unit rating
X • Integral LCD display provides easy readability of settings, metering values,
and event log

Overload protection

LCD display

6
GuardEon
Versatile design
Whether you mount GuardEon vertically or horizontally, the nameplate rotates
to allow easy readability of the important rating information. Clear on/trip/off
indication can easily been seen from afar. Terminal covers are attached and
hinged to prevent them from being misplaced.

Field interchangeable and upgradeable trip units


Have a need to add protective trip functions or advanced features such as com-
munications or Reduced Energy Let-Through (RELT)? GuardEon allows field
interchangeable and upgradeable trip units.

Plug and Play advanced features


Advanced features in the PremEon G trip unit can be added with plug and play

Key features
modules; Communications, Zone Selective Interlocking (ZSI), Reduced Energy
Let-Through (RELT), and protective relays can all be added to a basic circuit
breaker in the field. Simply connect a hardware accessory and the trip unit will
automatically detect the features associated with it and enable the corresponding
user interface.

Full array of accessories


GuardEon has a full array of field installable accessories:
• Terminations – flat, extended, twisted, 90°, and rear connections
• Rotary handles – direct mount, panel mount, NFPA 79 conformity Intro
• Motor operators – external for toggle mechanisms;
• Full set of auxiliary contacts and releases
• Residual current devices
• Plug-in and draw-out devices A
• Box clamps and lugs – for copper and aluminum conductors
• Many more…
B

7
GuardEon
UL489
Circuit breaker type PE150
Interruption tier B C E N H L
Poles Number of 2(1), 3, 4
Maximum voltage rating Volts AC 600
Volts DC 500
Interrupting Ratings - rms symmetrical 240V AC 35 42 65 100 150 200
amperes (kA) 480V AC 18 25 35 65 100 150
600V AC 14 18 25 35 42 65
250V DC two pole 25 50 85 100
500V DC three pole 25 50 85 100
Trip Units Interchangeable Yes
Thermal magnetic line LTM
Thermal magnetic generator GTM
Thermal magnetic discriminating LTMD
Magnetic only Mag Break or PremEon S
Electronic standard PremEon S
Electronic enhanced PremEon G

EN 60947-2
Circuit breaker type PE150
Denomination B C E N H L
GuardEon*

Poles Number of 2(1), 3, 4


Rated Insulation Voltage (Ui) Volts 750
Rated Impulse withstand voltage (Uimp) Kilovolts 8
Rated operational voltage Ue Volts AC 690
Volts DC 500
Category of use A A A A A A
Suitable for use as a isolator Yes Yes Yes Yes Yes Yes
Rated current Ith=Ie A at 40C 160
Ultimate breaking capacity Icu (kA) 230/240V AC 36 42 65 100 150 200
400/415V AC 18 25 36 50 100 150
440V AC 18 25 36 50 100 150
500V AC 14 18 30 42 50 100
690V AC 10 12 22 25 30 50
Intro 250V DC two pole
500V DC three pole
-
-
-
-
25
25
50
50
85
85
100
100
Service breaking capacity Ics (kA) 230/240V AC 36 42 65 100 150 200
400/415V AC 18 25 36 50 100 130
440V AC 18 25 36 50 100 130
A 500V AC
690V AC
14
10
18
12
30
17
42
19
50
20
100
20
250V DC two pole - - 25 50 85 100
500V DC three pole - - 25 50 85 100
Making capacity Icm (kA peak) 400/415V AC 36 53 76 105 220 330

B Single phase breaking capacity IIT (kA)


500V AC
230V AC
28
18
36
25
63
36
88
50
105
100
220
150
400/415V AC 10 12 22 25 30 38
Endurance (CO operations) Mechanical 25000
Electrical at In and 415V AC 10000
Electrical at In/2 and 415V AC 20000
C Endurance (On-tripped operations)
Trip Units
Mechanical
Interchangeable
10000
Yes
Thermal magnetic line LTM
Thermal magnetic generator GTM
Magnetic only Mag Break or PremEon S
D Electronic standard
Electronic enhanced
PremEon S
PremEon G

EN 60947-3
E Non Automatic Circuit Breaker/Switch Type
Denomination
PE150
Y
Rated current In (class AC23) 220V AC to 690V AC 150
Rated making capacity Icm (kA peak) 4,2
Short-term withstand current Icw (A) Icw eff.1 second 3
Icw eff. 3 seconds 3
F
EN 60947-4
Use in motor circuits
Rated current Ith A at 65° C 150
G Endurance (CO operations) Mechanical
Electrical at In class AC23 @415VAC
25000
10000
Operations per hour 120
Protection Short circuit only (separate overload device) Mag-Break/PremEon S & PremEon G
Overload class 10 and short circuit PremEon S & PremEon G

X Max In (A) class 10


Max In (A) class 30
150
150
Earth fault unit (differential)

Installation
Mounting DIN-Rail Yes
Fixed Yes
Plug-in Yes
Draw-out Yes
Connection Front Yes
Rear Yes
Poles Number of 2(1) 3 4
Dimensions (mm) w Fixed front connection 105 105 140
h 170 170 170
d 95 95 95

(1) Three pole footprint (4) - Only 8kv with PremEon G (Voltage sensing) & PremEon S
(2) Toggle mechanism (5) - Limited to 500A only
8 (3) Stored energy mechanism (6) - Please contact GE
GuardEon
UL489
Circuit breaker type PE250
Interruption tier B C E N H L
Poles Number of 2(1), 3, 4
Maximum voltage rating Volts AC 600
Volts DC 500
Interrupting Ratings - rms symmetrical 240V AC 35 42 65 100 150 200
amperes (kA) 480V AC 18 25 35 65 100 150
600V AC 14 18 25 35 42 65
250V DC two pole 25 50 85 100
500V DC three pole 25 50 85 100
Trip Units Interchangeable Yes
Thermal magnetic line LTM
Thermal magnetic generator GTM
Thermal magnetic discriminating LTMD
Magnetic only Mag Break or PremEon S
Electronic standard PremEon S
Electronic enhanced PremEon G

EN 60947-2

Ratings table
Circuit breaker type PE250
Denomination B C E N H L
Poles Number of 2(1), 3, 4
Rated Insulation Voltage (Ui) Volts 750
Rated Impulse withstand voltage (Uimp) Kilovolts 8
Rated operational voltage Ue Volts AC 690
Volts DC 500
Category of use A A A A A A
Suitable for use as a isolator Yes Yes Yes Yes Yes Yes
Rated current Ith=Ie A at 40C 250
Ultimate breaking capacity Icu (kA) 230/240V AC 36 42 65 100 150 200
400/415V AC 18 25 36 50 100 150
440V AC 18 25 36 50 100 150
500V AC 14 18 30 42 50 100
690V AC 10 12 22 25 30 50
250V DC two pole
500V DC three pole
-
-
-
-
25
25
50
50
85
85
100
100
Intro
Service breaking capacity Ics (kA) 230/240V AC 36 42 65 100 150 200
400/415V AC 18 25 36 50 100 130
440V AC 18 25 36 50 100 130
500V AC
690V AC
14
10
18
12
30
17
42
19
50
20
100
20 A
250V DC two pole - - 25 50 85 100
500V DC three pole - - 25 50 85 100
Making capacity Icm (kA peak) 400/415V AC 36 53 76 105 220 330

Single phase breaking capacity IIT (kA)


500V AC
230V AC
28
18
36
25
63
36
88
50
105
100
220
150 B
400/415V AC 10 12 22 15 25 38
Endurance (CO operations) Mechanical 25000
Electrical at In and 415V AC 10000
Electrical at In/2 and 415V AC 20000
Endurance (On-tripped operations)
Trip Units
Mechanical
Interchangeable
10000
Yes
C
Thermal magnetic line LTM
Thermal magnetic generator GTM
Magnetic only Mag Break or PremEon S
Electronic standard
Electronic enhanced
PremEon S
PremEon G
D
EN 60947-3
Non Automatic Circuit Breaker/Switch Type
Denomination
PE250
Y E
Rated current In (class AC23) 220V AC to 690V AC 250
Rated making capacity Icm (kA peak) 5,7
Short-term withstand current Icw (A) Icw eff.1 second 4
Icw eff. 3 seconds 4
F
EN 60947-4
Use in motor circuits
Rated current Ith A at 65° C 230
Endurance (CO operations) Mechanical
Electrical at In class AC23 @415VAC
25000
10000
G
Operations per hour 120
Protection Short circuit only (separate overload device) PremEon S & PremEon G
Overload class 10 and short circuit PremEon S & PremEon G
Max In (A) class 10
Max In (A) class 30
225
225 X
Earth fault unit (differential)

Installation
Mounting DIN-Rail Yes
Fixed Yes
Plug-in Yes
Draw-out Yes
Connection Front Yes
Rear Yes
Poles Number of 2(1) 3 4
Dimensions (mm) w Fixed front connection 105 105 140
h 170 170 170
d 95 95 95

9
GuardEon
UL489
Circuit breaker type PG600
Interruption tier C E N H L P
Poles Number of 2(1), 3, 4
Maximum voltage rating Volts AC 600
Volts DC -
Interrupting Ratings - rms symmetrical 240V AC 42 65 100 150 200 200
amperes (kA) 480V AC 25 35 65 100 150 600
600V AC 18 22 25 35 42 65
250V DC two pole -
500V DC three pole -
Trip Units Interchangeable
Thermal magnetic line -
Thermal magnetic generator -
Thermal magnetic discriminating -
Magnetic only PremEon S
Electronic standard PremEon S
Electronic enhanced PremEon G

EN 60947-2
Circuit breaker type PG600
Denomination C E N H L P
GuardEon*

Poles Number of 2(1), 3, 4


Rated Insulation Voltage (Ui) Volts 750
Rated Impulse withstand voltage (Uimp) Kilovolts 8
Rated operational voltage Ue Volts AC 690
Volts DC
Category of use B(5) B(5) B(5) B(5) B(5) B(5)
Suitable for use as a isolator Yes Yes Yes Yes Yes Yes
Rated current Ith=Ie A at 40C
Ultimate breaking capacity Icu (kA) 230/240V AC 42 65 100 150 200 200
400/415V AC 25 36 50 100 150 150
440V AC 25 36 50 100 130 130
500V AC 18 30 42 50 100 100
690V AC 12 22 25 30 40 40
Intro 250V DC two pole
500V DC three pole
Service breaking capacity Ics (kA) 230/240V AC 42 65 100 150 200 200
400/415V AC 25 36 50 100 150 150
440V AC 25 36 50 100 130 130
A 500V AC
690V AC
18
10
30
10
42
10
50
10
100
10
100
10
250V DC two pole
500V DC three pole
Making capacity Icm (kA peak) 400/415V AC 53 76 105 220 330 330

B Single phase breaking capacity IIT (kA)


500V AC
230V AC
36
25
63
36
88
50
105
50
220
50
220
50
400/415V AC 10 10 10 10 10 10
Endurance (CO operations) Mechanical 20000
Electrical at In and 415V AC 5000
Electrical at In/2 and 415V AC 10000
C Endurance (On-tripped operations)
Trip Units
Mechanical
Interchangeable
8000
Yes
Thermal magnetic line -
Thermal magnetic generator -
Magnetic only PremEon S
D Electronic standard
Electronic enhanced
PremEon S
PremEon G

EN 60947-3
E Non Automatic Circuit Breaker/Switch Type
Denomination
PG600
Y
Rated current In (class AC23) 220V AC to 690V AC 600
Rated making capacity Icm (kA peak) 9,2
Short-term withstand current Icw (A) Icw eff.1 second 6,5
Icw eff. 3 seconds 5,0
F
EN 60947-4
Use in motor circuits
Rated current Ith A at 65° C 500
G Endurance (CO operations) Mechanical
Electrical at In class AC23 @415VAC
20000
5000
Operations per hour 60
Protection Short circuit only (separate overload device) PremEon S & PremEon G
Overload class 10 and short circuit PremEon S & PremEon G

X Max In (A) class 10


Max In (A) class 30
500
500
Earth fault unit (differential) -

Installation
Mounting DIN-Rail No
Fixed Yes
Plug-in Yes
Draw-out Yes
Connection Front Yes
Rear Yes
Poles Number of 2(1) 3 4 4
Dimensions (mm) w
 Fixed front connection 140 140 185 185
h 265 265 265 265
d 115 115 115 115

(1) Three pole footprint (4) - Only 8kv with PremEon G (Voltage sensing) & PremEon S
(2) Toggle mechanism (5) - Limited to 500A only
10 (3) Stored energy mechanism (6) - Please contact GE
GuardEon

Catalog number structure


A.2 E Frame
A.3 G Frame
GuardEon overview The circuit breaker Intro
A.4 Available breaking capacities and protection: GuardEon overview
Order codes A
Order codes
Trip units B
E Frame
A.6 Thermal magnetic trip units – 20-250A
Components and accessories C
A.16 Electronic trip units – 25A
A.20 Electronic trip units – 60A
Technical data D
A.22 Electronic trip units – 125A
A.26 Electronic trip units – 250A
Application guide E
G Frame
A.34 Electronic trip units – 600A
Wiring diagrams F

Dimensions G

Numerical Index X

A.1
GuardEon
Catalog number structure - E Frame

1st digit 5th digit 9th digit


Family Number of poles/Neutral rating (if applicable) LTM Trip function
Character Description Character Description Character Description
P GuardEon Thermals / Magnetics
2 Two pole N Fixed / Fixed
3 Three pole R Fixed/Adjustable
4 Four pole ETU trip function
Notes B L(S)I

PremEon S
Two pole in a three pole construction for E & G frames. E L(S)IG
Neutral is settable from off to 100% with ETU F (S)I
H (S)IG
Four pole circuit breakers factory set to 100% neutral
protection. Field settable to 50% or OFF. U Non-automatic
J LSI

PremEon G
GuardEon*

K LISG
GuardEon

L LSIGA
M LSIGD

3rd digit Notes


Certification Parenthesis for non-adjustable function
LSIGD = LSIG with switchable GF
Character Description
A PE150

Intro B
D
PE150 - 100% rated
PE250
E PE250 - 100% rated

A 7th digit
Mechanism
Character Description
B T Toggle

C EX.:
P E A N 2 A T T N 0040
D

E 2nd digit
Frame rating
6th digit
Connection
Digits 10-13
Ampere rating
Character Description Character Description Character Description
E 250A Top Bottom Thermal Electronic
F A Front Front 0020 20A
0025 25A 8-25A
4th digit 8th digit 0030 30A
G Current limiting
interruption ratings -
Trip unit 0035 35A
Character Description 0040 40A
Ultimate breaking
capacity Icu T Line thermal magnetic 0050 50A

X Character Description G Generator thermal magnetic 0060


0070
60A
70A
18-60A

B 18kA S PremEon S
A PremEon G - Current 0080 80A
C 25kA
E PremEon G - Advanced metering 0090 90A
E 35kA
D Switch 0100 100A
N 65kA
0110 110A
H 100kA
Notes 0125 125A 38-125A
L 150kA Two pole in a three pole construction.
0150 150A 45-150A
Y switch Neutral settable from off to 100% with
PremEon S & G. PremEon G - Advanced me- 0200 200A
Notes tering includes internal voltage sensing and 0225 225A
@415V AC predictive maintenance features including 0250 250A 75-250A
contact wear and mechanism timing.
xxx None None

A.2
GuardEon
Catalog number structure - G Frame

1st digit 5th digit 9th digit


Family Number of poles/Neutral rating (if applicable) ETU Trip function
Character Description Character Description Character Description
P GuardEon 2 Two pole B L(S)I

Catalog number structure


PremEon S
3 Three pole E L(S)IG
4 Four pole F (S)I
H (S)IG
Notes
U Non-automatic
Two pole in a three pole construction for E & G frames.
Neutral is settable from off to 100% with ETU J LSI

PremEon G
K LISG
Four pole circuit breakers factory set to 100% neutral L LSIGA
protection. Field settable to 50% or OFF.
M LSIGD

Notes
Parenthesis for non-adjustable function
LSIGD = LSIG with switchable GF

3rd digit
Certification
Character Description
F PG600
G PG600 - Ext Inst
Intro
Note
Extended instantaneous breakers are
optimized for selectivity
7th digit A
Mechanism
Character Description
T Toggle B

EX.: C
P G F N 3 A T S B 0250
D

2nd digit
Frame rating
6th digit
Connection
Digits 10-13
Ampere rating
E
Character Description Character Description Character Description
G 600A Line side Load side 0250 75-250A
A Front Front 0400 120-400A F
0600 180-600A
4th digit 8th digit
Current limiting
interruption ratings -
Trip unit G
Ultimate breaking Character Description
capacity Icu S PremEon S
Character Description A
E
PremEon G - Current
PremEon G - Advanced metering
X
C 25kA
E 35kA D Disconnector
N 65kA Notes
H 100kA Two pole in a three pole construction.
L 150kA Neutral settable from off to 100% with
P 200kA PremEon S & G. PremEon G - Advanced me-
Y

tering includes internal voltage sensing and


Notes predictive maintenance features including
@415V AC contact wear and mechanism timing.

A.3
GuardEon
Available breaking capacities and protection: GuardEon overview

Available breaking capacities - Interuption ratings - Icu 480V AC in kA eff


Current Limiting
Type B C E N H L P

PE150 18 25 36 50 100 150 -


PE250 18 25 36 50 100 150 -
PE600 N/A 25 36 50 100 150 200

Available trip protection


Type Magnetic Line thermal Selective Generator PremEon S PremEon G PremEon G(1) Disconnector
only magnetic thermal thermal current advanced
magnetic magnetic metering
N T L G S A E D
GuardEon

PE150 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
PE250 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
PE600 N/A N/A N/A N/A ✔ ✔ ✔ ✔

(1) PremEon G - Advanced metering includes internal voltage sensing and predictive maintenance features

Available number of poles


Poles Two pole(2) Three pole Four pole Four pole Four pole Four pole Four pole Four pole
Intro left neutral left neutral left neutral right neutral right neutral right neutral
100% 50% off 100% 50% off
2 3 4 5 6 7 8 9

PE150
A
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
PE250 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔
PE600 ✔ ✔ ✔ ✔ ✔ N/A N/A N/A

B (2) Two pole in a three pole construction for E & G Frames / Neutral is settable from off to 100% with ETU

A.4
GuardEon
Complete circuit breaker - GuardEon with UL PE150

Thermal Magnetic - 2 poles


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
Line Thermal Magnetic (LTM)  
20 PEAB2ATTN0020 PEAC2ATTN0020 PEAE2ATTN0020 PEAN2ATTN0020 PEAH2ATTN0020 PEAL2ATTN0020
25 PEAB2ATTN0025 PEAC2ATTN0025 PEAE2ATTN0025 PEAN2ATTN0025 PEAH2ATTN0025 PEAL2ATTN0025
30 PEAB2ATTN0030 PEAC2ATTN0030 PEAE2ATTN0030 PEAN2ATTN0030 PEAH2ATTN0030 PEAL2ATTN0030
40 PEAB2ATTN0040 PEAC2ATTN0040 PEAE2ATTN0040 PEAN2ATTN0040 PEAH2ATTN0040 PEAL2ATTN0040
50 PEAB2ATTN0050 PEAC2ATTN0050 PEAE2ATTN0050 PEAN2ATTN0050 PEAH2ATTN0050 PEAL2ATTN0050
60 PEAB2ATTN0060 PEAC2ATTN0060 PEAE2ATTN0060 PEAN2ATTN0060 PEAH2ATTN0060 PEAL2ATTN0060
70 PEAB2ATTR0070 PEAC2ATTR0070 PEAE2ATTR0070 PEAN2ATTR0070 PEAH2ATTR0070 PEAL2ATTR0070
80 PEAB2ATTR0080 PEAC2ATTR0080 PEAE2ATTR0080 PEAN2ATTR0080 PEAH2ATTR0080 PEAL2ATTR0080
90 PEAB2ATTR0090 PEAC2ATTR0090 PEAE2ATTR0090 PEAN2ATTR0090 PEAH2ATTR0090 PEAL2ATTR0090
GuardEon

100 PEAB2ATTR0100 PEAC2ATTR0100 PEAE2ATTR0100 PEAN2ATTR0100 PEAH2ATTR0100 PEAL2ATTR0100


110 PEAB2ATTR0110 PEAC2ATTR0110 PEAE2ATTR0110 PEAN2ATTR0110 PEAH2ATTR0110 PEAL2ATTR0110
125 PEAB2ATTR0125 PEAC2ATTR0125 PEAE2ATTR0125 PEAN2ATTR0125 PEAH2ATTR0125 PEAL2ATTR0125
150 PEAB2ATTR0150 PEAC2ATTR0150 PEAE2ATTR0150 PEAN2ATTR0150 PEAH2ATTR0150 PEAL2ATTR0150

Intro Generator Thermal Magnetic (GTM)


100 PEAB2ATGS0100 PEAC2ATGS0100 PEAE2ATGS0100 PEAN2ATGS0100 PEAH2ATGS0100 PEAL2ATGS0100
110 PEAB2ATGS0110 PEAC2ATGS0110 PEAE2ATGS0110 PEAN2ATGS0110 PEAH2ATGS0110 PEAL2ATGS0110
125 PEAB2ATGS0125 PEAC2ATGS0125 PEAE2ATGS0125 PEAN2ATGS0125 PEAH2ATGS0125 PEAL2ATGS0125
150 PEAB2ATGS0150 PEAC2ATGS0150 PEAE2ATGS0150 PEAN2ATGS0150 PEAH2ATGS0150 PEAL2ATGS0150
A

B
Thermal Magnetic - 100% UL rated - 2 poles
C In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
D Line Thermal Magnetic (LTM)  
20 PEBB2ATTN0020 PEBC2ATTN0020 PEBE2ATTN0020 PEBN2ATTN0020 PEBH2ATTN0020 PEBL2ATTN0020
25 PEBB2ATTN0025 PEBC2ATTN0025 PEBE2ATTN0025 PEBN2ATTN0025 PEBH2ATTN0025 PEBL2ATTN0025
30 PEBB2ATTN0030 PEBC2ATTN0030 PEBE2ATTN0030 PEBN2ATTN0030 PEBH2ATTN0030 PEBL2ATTN0030
E 40
50
PEBB2ATTN0040
PEBB2ATTN0050
PEBC2ATTN0040
PEBC2ATTN0050
PEBE2ATTN0040
PEBE2ATTN0050
PEBN2ATTN0040
PEBN2ATTN0050
PEBH2ATTN0040
PEBH2ATTN0050
PEBL2ATTN0040
PEBL2ATTN0050
60 PEBB2ATTN0060 PEBC2ATTN0060 PEBE2ATTN0060 PEBN2ATTN0060 PEBH2ATTN0060 PEBL2ATTN0060
70 PEBB2ATTR0070 PEBC2ATTR0070 PEBE2ATTR0070 PEBN2ATTR0070 PEBH2ATTR0070 PEBL2ATTR0070
80 PEBB2ATTR0080 PEBC2ATTR0080 PEBE2ATTR0080 PEBN2ATTR0080 PEBH2ATTR0080 PEBL2ATTR0080
F 90
100
PEBB2ATTR0090
PEBB2ATTR0100
PEBC2ATTR0090
PEBC2ATTR0100
PEBE2ATTR0090
PEBE2ATTR0100
PEBN2ATTR0090
PEBN2ATTR0100
PEBH2ATTR0090
PEBH2ATTR0100
PEBL2ATTR0090
PEBL2ATTR0100
110 PEBB2ATTR0110 PEBC2ATTR0110 PEBE2ATTR0110 PEBN2ATTR0110 PEBH2ATTR0110 PEBL2ATTR0110
125 PEBB2ATTR0125 PEBC2ATTR0125 PEBE2ATTR0125 PEBN2ATTR0125 PEBH2ATTR0125 PEBL2ATTR0125
150 PEBB2ATTR0150 PEBC2ATTR0150 PEBE2ATTR0150 PEBN2ATTR0150 PEBH2ATTR0150 PEBL2ATTR0150
G

X Generator Thermal Magnetic (GTM)


100 PEBB2ATGR0100 PEBC2ATGR0100 PEBE2ATGR0100 PEBN2ATGR0100 PEBH2ATGR0100 PEBL2ATGR0100
110 PEBB2ATGR0110 PEBC2ATGR0110 PEBE2ATGR0110 PEBN2ATGR0110 PEBH2ATGR0110 PEBL2ATGR0110
125 PEBB2ATGR0125 PEBC2ATGR0125 PEBE2ATGR0125 PEBN2ATGR0125 PEBH2ATGR0125 PEBL2ATGR0125
150 PEBB2ATGR0150 PEBC2ATGR0150 PEBE2ATGR0150 PEBN2ATGR0150 PEBH2ATGR0150 PEBL2ATGR0150

A.6
GuardEon
Complete circuit breaker - GuardEon with UL PE150

Thermal Magnetic - 3 poles


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
Line Thermal Magnetic (LTM)  
20 PEAB3ATTN0020 PEAC3ATTN0020 PEAE3ATTN0020 PEAN3ATTN0020 PEAH3ATTN0020 PEAL3ATTN0020
25 PEAB3ATTN0025 PEAC3ATTN0025 PEAE3ATTN0025 PEAN3ATTN0025 PEAH3ATTN0025 PEAL3ATTN0025
30 PEAB3ATTN0030 PEAC3ATTN0030 PEAE3ATTN0030 PEAN3ATTN0030 PEAH3ATTN0030 PEAL3ATTN0030
40 PEAB3ATTN0040 PEAC3ATTN0040 PEAE3ATTN0040 PEAN3ATTN0040 PEAH3ATTN0040 PEAL3ATTN0040
50 PEAB3ATTN0050 PEAC3ATTN0050 PEAE3ATTN0050 PEAN3ATTN0050 PEAH3ATTN0050 PEAL3ATTN0050
60 PEAB3ATTN0060 PEAC3ATTN0060 PEAE3ATTN0060 PEAN3ATTN0060 PEAH3ATTN0060 PEAL3ATTN0060
70 PEAB3ATTR0070 PEAC3ATTR0070 PEAE3ATTR0070 PEAN3ATTR0070 PEAH3ATTR0070 PEAL3ATTR0070

Order codes
80 PEAB3ATTR0080 PEAC3ATTR0080 PEAE3ATTR0080 PEAN3ATTR0080 PEAH3ATTR0080 PEAL3ATTR0080
90 PEAB3ATTR0090 PEAC3ATTR0090 PEAE3ATTR0090 PEAN3ATTR0090 PEAH3ATTR0090 PEAL3ATTR0090
100 PEAB3ATTR0100 PEAC3ATTR0100 PEAE3ATTR0100 PEAN3ATTR0100 PEAH3ATTR0100 PEAL3ATTR0100
110 PEAB3ATTR0110 PEAC3ATTR0110 PEAE3ATTR0110 PEAN3ATTR0110 PEAH3ATTR0110 PEAL3ATTR0110
125 PEAB3ATTR0125 PEAC3ATTR0125 PEAE3ATTR0125 PEAN3ATTR0125 PEAH3ATTR0125 PEAL3ATTR0125
150 PEAB3ATTR0150 PEAC3ATTR0150 PEAE3ATTR0150 PEAN3ATTR0150 PEAH3ATTR0150 PEAL3ATTR0150

Generator Thermal Magnetic (GTM)


100 PEAB3ATGR0100 PEAC3ATGR0100 PEAE3ATGR0100 PEAN3ATGR0100 PEAH3ATGR0100 PEAL3ATGR0100
Intro
110 PEAB3ATGR0110 PEAC3ATGR0110 PEAE3ATGR0110 PEAN3ATGR0110 PEAH3ATGR0110 PEAL3ATGR0110
125 PEAB3ATGR0125 PEAC3ATGR0125 PEAE3ATGR0125 PEAN3ATGR0125 PEAH3ATGR0125 PEAL3ATGR0125
150 PEAB3ATGR0150 PEAC3ATGR0150 PEAE3ATGR0150 PEAN3ATGR0150 PEAH3ATGR0150 PEAL3ATGR0150
A
Non-automatic circuit breaker (switch rated at 40°C) - 3 poles
PEAY3ATDU0150

B
Thermal Magnetic - 100% UL rated - 3 poles
In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. C
Interrupt Rating @ 480V
18kA 25kA 35kA 65kA 100kA 150kA
Line Thermal Magnetic (LTM)   D
20 PEBB3ATTN0020 PEBC3ATTN0020 PEBE3ATTN0020 PEBN3ATTN0020 PEBH3ATTN0020 PEBL3ATTN0020
25 PEBB3ATTN0025 PEBC3ATTN0025 PEBE3ATTN0025 PEBN3ATTN0025 PEBH3ATTN0025 PEBL3ATTN0025
30 PEBB3ATTN0030 PEBC3ATTN0030 PEBE3ATTN0030 PEBN3ATTN0030 PEBH3ATTN0030 PEBL3ATTN0030
40
50
PEBB3ATTN0040
PEBB3ATTN0050
PEBC3ATTN0040
PEBC3ATTN0050
PEBE3ATTN0040
PEBE3ATTN0050
PEBN3ATTN0040
PEBN3ATTN0050
PEBH3ATTN0040
PEBH3ATTN0050
PEBL3ATTN0040
PEBL3ATTN0050
E
60 PEBB3ATTN0060 PEBC3ATTN0060 PEBE3ATTN0060 PEBN3ATTN0060 PEBH3ATTN0060 PEBL3ATTN0060
70 PEBB3ATTR0070 PEBC3ATTR0070 PEBE3ATTR0070 PEBN3ATTR0070 PEBH3ATTR0070 PEBL3ATTR0070
80 PEBB3ATTR0080 PEBC3ATTR0080 PEBE3ATTR0080 PEBN3ATTR0080 PEBH3ATTR0080 PEBL3ATTR0080
90
100
PEBB3ATTR0090
PEBB3ATTR0100
PEBC3ATTR0090
PEBC3ATTR0100
PEBE3ATTR0090
PEBE3ATTR0100
PEBN3ATTR0090
PEBN3ATTR0100
PEBH3ATTR0090
PEBH3ATTR0100
PEBL3ATTR0090
PEBL3ATTR0100 F
110 PEBB3ATTR0110 PEBC3ATTR0110 PEBE3ATTR0110 PEBN3ATTR0110 PEBH3ATTR0110 PEBL3ATTR0110
125 PEBB3ATTR0125 PEBC3ATTR0125 PEBE3ATTR0125 PEBN3ATTR0125 PEBH3ATTR0125 PEBL3ATTR0125
150 PEBB3ATTR0150 PEBC3ATTR0150 PEBE3ATTR0150 PEBN3ATTR0150 PEBH3ATTR0150 PEBL3ATTR0150
G

Generator Thermal Magnetic (GTM)


X
100 PEBB3ATGR0100 PEBC3ATGR0100 PEBE3ATGR0100 PEBN3ATGR0100 PEBH3ATGR0100 PEBL3ATGR0100
110 PEBB3ATGR0110 PEBC3ATGR0110 PEBE3ATGR0110 PEBN3ATGR0110 PEBH3ATGR0110 PEBL3ATGR0110
125 PEBB3ATGR0125 PEBC3ATGR0125 PEBE3ATGR0125 PEBN3ATGR0125 PEBH3ATGR0125 PEBL3ATGR0125
150 PEBB3ATGR0150 PEBC3ATGR0150 PEBE3ATGR0150 PEBN3ATGR0150 PEBH3ATGR0150 PEBL3ATGR0150

A.7
GuardEon
Complete circuit breaker - GuardEon with UL PE150

Thermal Magnetic - 4 poles(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
Line Thermal Magnetic (LTM)  
20 PEAB4ATTN0020 PEAC4ATTN0020 PEAE4ATTN0020 PEAN4ATTN0020 PEAH4ATTN0020 PEAL4ATTN0020
25 PEAB4ATTN0025 PEAC4ATTN0025 PEAE4ATTN0025 PEAN4ATTN0025 PEAH4ATTN0025 PEAL4ATTN0025
30 PEAB4ATTN0030 PEAC4ATTN0030 PEAE4ATTN0030 PEAN4ATTN0030 PEAH4ATTN0030 PEAL4ATTN0030
40 PEAB4ATTN0040 PEAC4ATTN0040 PEAE4ATTN0040 PEAN4ATTN0040 PEAH4ATTN0040 PEAL4ATTN0040
50 PEAB4ATTN0050 PEAC4ATTN0050 PEAE4ATTN0050 PEAN4ATTN0050 PEAH4ATTN0050 PEAL4ATTN0050
60 PEAB4ATTN0060 PEAC4ATTN0060 PEAE4ATTN0060 PEAN4ATTN0060 PEAH4ATTN0060 PEAL4ATTN0060
70 PEAB4ATTR0070 PEAC4ATTR0070 PEAE4ATTR0070 PEAN4ATTR0070 PEAH4ATTR0070 PEAL4ATTR0070
80 PEAB4ATTR0080 PEAC4ATTR0080 PEAE4ATTR0080 PEAN4ATTR0080 PEAH4ATTR0080 PEAL4ATTR0080
90 PEAB4ATTR0090 PEAC4ATTR0090 PEAE4ATTR0090 PEAN4ATTR0090 PEAH4ATTR0090 PEAL4ATTR0090
GuardEon

100 PEAB4ATTR0100 PEAC4ATTR0100 PEAE4ATTR0100 PEAN4ATTR0100 PEAH4ATTR0100 PEAL4ATTR0100


110 PEAB4ATTR0110 PEAC4ATTR0110 PEAE4ATTR0110 PEAN4ATTR0110 PEAH4ATTR0110 PEAL4ATTR0110
125 PEAB4ATTR0125 PEAC4ATTR0125 PEAE4ATTR0125 PEAN4ATTR0125 PEAH4ATTR0125 PEAL4ATTR0125
150 PEAB4ATTR0150 PEAC4ATTR0150 PEAE4ATTR0150 PEAN4ATTR0150 PEAH4ATTR0150 PEAL4ATTR0150

Intro Generator Thermal Magnetic (GTM)


100 PEAB4ATGR0100 PEAC4ATGR0100 PEAE4ATGR0100 PEAN4ATGR0100 PEAH4ATGR0100 PEAL4ATGR0100
110 PEAB4ATGR0110 PEAC4ATGR0110 PEAE4ATGR0110 PEAN4ATGR0110 PEAH4ATGR0110 PEAL4ATGR0110
125 PEAB4ATGR0125 PEAC4ATGR0125 PEAE4ATGR0125 PEAN4ATGR0125 PEAH4ATGR0125 PEAL4ATGR0125
150 PEAB4ATGR0150 PEAC4ATGR0150 PEAE4ATGR0150 PEAN4ATGR0150 PEAH4ATGR0150 PEAL4ATGR0150
A

B
Thermal Magnetic - 100% UL rated - 4 poles(1)
C In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
D Line Thermal Magnetic (LTM)  
20 PEBB4ATTN0020 PEBC4ATTN0020 PEBE4ATTN0020 PEBN4ATTN0020 PEBH4ATTN0020 PEBL4ATTN0020
25 PEBB4ATTN0025 PEBC4ATTN0025 PEBE4ATTN0025 PEBN4ATTN0025 PEBH4ATTN0025 PEBL4ATTN0025
30 PEBB4ATTN0030 PEBC4ATTN0030 PEBE4ATTN0030 PEBN4ATTN0030 PEBH4ATTN0030 PEBL4ATTN0030
E 40
50
PEBB4ATTN0040
PEBB4ATTN0050
PEBC4ATTN0040
PEBC4ATTN0050
PEBE4ATTN0040
PEBE4ATTN0050
PEBN4ATTN0040
PEBN4ATTN0050
PEBH4ATTN0040
PEBH4ATTN0050
PEBL4ATTN0040
PEBL4ATTN0050
60 PEBB4ATTN0060 PEBC4ATTN0060 PEBE4ATTN0060 PEBN4ATTN0060 PEBH4ATTN0060 PEBL4ATTN0060
70 PEBB4ATTR0070 PEBC4ATTR0070 PEBE4ATTR0070 PEBN4ATTR0070 PEBH4ATTR0070 PEBL4ATTR0070
80 PEBB4ATTR0080 PEBC4ATTR0080 PEBE4ATTR0080 PEBN4ATTR0080 PEBH4ATTR0080 PEBL4ATTR0080
F 90
100
PEBB4ATTR0090
PEBB4ATTR0100
PEBC4ATTR0090
PEBC4ATTR0100
PEBE4ATTR0090
PEBE4ATTR0100
PEBN4ATTR0090
PEBN4ATTR0100
PEBH4ATTR0090
PEBH4ATTR0100
PEBL4ATTR0090
PEBL4ATTR0100
110 PEBB4ATTR0110 PEBC4ATTR0110 PEBE4ATTR0110 PEBN4ATTR0110 PEBH4ATTR0110 PEBL4ATTR0110
125 PEBB4ATTR0125 PEBC4ATTR0125 PEBE4ATTR0125 PEBN4ATTR0125 PEBH4ATTR0125 PEBL4ATTR0125
150 PEBB4ATTR0150 PEBC4ATTR0150 PEBE4ATTR0150 PEBN4ATTR0150 PEBH4ATTR0150 PEBL4ATTR0150
G

X Generator Thermal Magnetic (GTM)


100 PEBB4ATGR0100 PEBC4ATGR0100 PEBE4ATGR0100 PEBN4ATGR0100 PEBH4ATGR0100 PEBL4ATGR0100
110 PEBB4ATGR0110 PEBC4ATGR0110 PEBE4ATGR0110 PEBN4ATGR0110 PEBH4ATGR0110 PEBL4ATGR0110
125 PEBB4ATGR0125 PEBC4ATGR0125 PEBE4ATGR0125 PEBN4ATGR0125 PEBH4ATGR0125 PEBL4ATGR0125
150 PEBB4ATGR0150 PEBC4ATGR0150 PEBE4ATGR0150 PEBN4ATGR0150 PEBH4ATGR0150 PEBL4ATGR0150

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.8
GuardEon
Complete circuit breaker - GuardEon with UL PE250

Thermal Magnetic - 2 poles


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
Line Thermal Magnetic (LTM)  
125 PEDB2ATTR0125 PEDC2ATTR0125 PEDE2ATTR0125 PEDN2ATTR0125 PEDH2ATTR0125 PEDL2ATTR0125
150 PEDB2ATTR0150 PEDC2ATTR0150 PEDE2ATTR0150 PEDN2ATTR0150 PEDH2ATTR0150 PEDL2ATTR0150
200 PEDB2ATTR0200 PEDC2ATTR0200 PEDE2ATTR0200 PEDN2ATTR0200 PEDH2ATTR0200 PEDL2ATTR0200
225 PEDB2ATTR0225 PEDC2ATTR0225 PEDE2ATTR0225 PEDN2ATTR0225 PEDH2ATTR0225 PEDL2ATTR0225
250 PEDB2ATTR0250 PEDC2ATTR0250 PEDE2ATTR0250 PEDN2ATTR0250 PEDH2ATTR0250 PEDL2ATTR0250

Order codes
Generator Thermal Magnetic (GTM)
125 PEDB2ATGR0125 PEDC2ATGR0125 PEDE2ATGR0125 PEDN2ATGR0125 PEDH2ATGR0125 PEDL2ATGR0125
150 PEDB2ATGR0150 PEDC2ATGR0150 PEDE2ATGR0150 PEDN2ATGR0150 PEDH2ATGR0150 PEDL2ATGR0150
200
225
PEDB2ATGR0200
PEDB2ATGR0225
PEDC2ATGR0200
PEDC2ATGR0225
PEDE2ATGR0200
PEDE2ATGR0225
PEDN2ATGR0200
PEDN2ATGR0225
PEDH2ATGR0200
PEDH2ATGR0225
PEDL2ATGR0200
PEDL2ATGR0225 Intro
250 PEDB2ATGR0250 PEDC2ATGR0250 PEDE2ATGR0250 PEDN2ATGR0250 PEDH2ATGR0250 PEDL2ATGR0250

B
Thermal Magnetic - 100% UL rated - 2 poles
In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. C
Interrupt Rating @ 480V
18kA 25kA 35kA 65kA 100kA 150kA
Line Thermal Magnetic (LTM)   D
125 PEEB2ATTR0125 PEEC2ATTR0125 PEEE2ATTR0125 PEEN2ATTR0125 PEEH2ATTR0125 PEEL2ATTR0125
150 PEEB2ATTR0150 PEEC2ATTR0150 PEEE2ATTR0150 PEEN2ATTR0150 PEEH2ATTR0150 PEEL2ATTR0150
200 PEEB2ATTR0200 PEEC2ATTR0200 PEEE2ATTR0200 PEEN2ATTR0200 PEEH2ATTR0200 PEEL2ATTR0200
225
250
PEEB2ATTR0225
PEEB2ATTR0250
PEEC2ATTR0225
PEEC2ATTR0250
PEEE2ATTR0225
PEEE2ATTR0250
PEEN2ATTR0225
PEEN2ATTR0250
PEEH2ATTR0225
PEEH2ATTR0250
PEEL2ATTR0225
PEEL2ATTR0250
E

G
Generator Thermal Magnetic (GTM)
125 PEEB2ATGS0125 PEEC2ATGS0125 PEEE2ATGS0125 PEEN2ATGS0125 PEEH2ATGS0125 PEEL2ATGS0125
150
200
PEEB2ATGS0150
PEEB2ATGS0200
PEEC2ATGS0150
PEEC2ATGS0200
PEEE2ATGS0150
PEEE2ATGS0200
PEEN2ATGS0150
PEEN2ATGS0200
PEEH2ATGS0150
PEEH2ATGS0200
PEEL2ATGS0150
PEEL2ATGS0200 X
225 PEEB2ATGS0225 PEEC2ATGS0225 PEEE2ATGS0225 PEEN2ATGS0225 PEEH2ATGS0225 PEEL2ATGS0225
250 PEEB2ATGS0250 PEEC2ATGS0250 PEEE2ATGS0250 PEEN2ATGS0250 PEEH2ATGS0250 PEEL2ATGS0250

A.9
GuardEon
Complete circuit breaker - GuardEon with UL PE250

Thermal Magnetic - 3 poles


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
Line Thermal Magnetic (LTM)  
125 PEDB3ATTS0125 PEDC3ATTS0125 PEDE3ATTS0125 PEDN3ATTS0125 PEDH3ATTS0125 PEDL3ATTS0125
150 PEDB3ATTS0150 PEDC3ATTS0150 PEDE3ATTS0150 PEDN3ATTS0150 PEDH3ATTS0150 PEDL3ATTS0150
200 PEDB3ATTS0200 PEDC3ATTS0200 PEDE3ATTS0200 PEDN3ATTS0200 PEDH3ATTS0200 PEDL3ATTS0200
225 PEDB3ATTS0225 PEDC3ATTS0225 PEDE3ATTS0225 PEDN3ATTS0225 PEDH3ATTS0225 PEDL3ATTS0225
250 PEDB3ATTS0250 PEDC3ATTS0250 PEDE3ATTS0250 PEDN3ATTS0250 PEDH3ATTS0250 PEDL3ATTS0250
GuardEon

Generator Thermal Magnetic (GTM)


125 PEDB3ATGR0125 PEDC3ATGR0125 PEDE3ATGR0125 PEDN3ATGR0125 PEDH3ATGR0125 PEDL3ATGR0125
150 PEDB3ATGR0150 PEDC3ATGR0150 PEDE3ATGR0150 PEDN3ATGR0150 PEDH3ATGR0150 PEDL3ATGR0150
200 PEDB3ATGR0200 PEDC3ATGR0200 PEDE3ATGR0200 PEDN3ATGR0200 PEDH3ATGR0200 PEDL3ATGR0200
Intro 225
250
PEDB3ATGR0225
PEDB3ATGR0250
PEDC3ATGR0225
PEDC3ATGR0250
PEDE3ATGR0225
PEDE3ATGR0250
PEDN3ATGR0225
PEDN3ATGR0250
PEDH3ATGR0225
PEDH3ATGR0250
PEDL3ATGR0225
PEDL3ATGR0250

Non-automatic circuit breaker (switch rated at 40°C) - 3 poles

A PEAY3ATDU0250

B
Thermal Magnetic - 100% UL rated - 3 poles
C In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA

D Line Thermal Magnetic (LTM)  


125 PEEB3ATTS0125 PEEC3ATTS0125 PEEE3ATTS0125 PEEN3ATTS0125 PEEH3ATTS0125 PEEL3ATTS0125
150 PEEB3ATTS0150 PEEC3ATTS0150 PEEE3ATTS0150 PEEN3ATTS0150 PEEH3ATTS0150 PEEL3ATTS0150
200 PEEB3ATTS0200 PEEC3ATTS0200 PEEE3ATTS0200 PEEN3ATTS0200 PEEH3ATTS0200 PEEL3ATTS0200
E 225
250
PEEB3ATTS0225
PEEB3ATTS0250
PEEC3ATTS0225
PEEC3ATTS0250
PEEE3ATTS0225
PEEE3ATTS0250
PEEN3ATTS0225
PEEN3ATTS0250
PEEH3ATTS0225
PEEH3ATTS0250
PEEL3ATTS0225
PEEL3ATTS0250

G
Generator Thermal Magnetic (GTM)
125 PEEB3ATGR0125 PEEC3ATGR0125 PEEE3ATGR0125 PEEN3ATGR0125 PEEH3ATGR0125 PEEL3ATGR0125
150 PEEB3ATGR0150 PEEC3ATGR0150 PEEE3ATGR0150 PEEN3ATGR0150 PEEH3ATGR0150 PEEL3ATGR0150
X 200 PEEB3ATGR0200 PEEC3ATGR0200 PEEE3ATGR0200 PEEN3ATGR0200 PEEH3ATGR0200 PEEL3ATGR0200
225 PEEB3ATGR0225 PEEC3ATGR0225 PEEE3ATGR0225 PEEN3ATGR0225 PEEH3ATGR0225 PEEL3ATGR0225
250 PEEB3ATGR0250 PEEC3ATGR0250 PEEE3ATGR0250 PEEN3ATGR0250 PEEH3ATGR0250 PEEL3ATGR0250

A.10
GuardEon
Complete circuit breaker - GuardEon with UL PE250

Thermal Magnetic - 4 poles(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
Line Thermal Magnetic (LTM)  
125 PEDB4ATTR0125 PEDC4ATTR0125 PEDE4ATTR0125 PEDN4ATTR0125 PEDH4ATTR0125 PEDL4ATTR0125
150 PEDB4ATTR0150 PEDC4ATTR0150 PEDE4ATTR0150 PEDN4ATTR0150 PEDH4ATTR0150 PEDL4ATTR0150
200 PEDB4ATTR0200 PEDC4ATTR0200 PEDE4ATTR0200 PEDN4ATTR0200 PEDH4ATTR0200 PEDL4ATTR0200
225 PEDB4ATTR0225 PEDC4ATTR0225 PEDE4ATTR0225 PEDN4ATTR0225 PEDH4ATTR0225 PEDL4ATTR0225
250 PEDB4ATTR0250 PEDC4ATTR0250 PEDE4ATTR0250 PEDN4ATTR0250 PEDH4ATTR0250 PEDL4ATTR0250

Order codes
Generator Thermal Magnetic (GTM)
125 PEDB4ATGR0125 PEDC4ATGR0125 PEDE4ATGR0125 PEDN4ATGR0125 PEDH4ATGR0125 PEDL4ATGR0125
150 PEDB4ATGR0150 PEDC4ATGR0150 PEDE4ATGR0150 PEDN4ATGR0150 PEDH4ATGR0150 PEDL4ATGR0150
200 PEDB4ATGR0200 PEDC4ATGR0200 PEDE4ATGR0200 PEDN4ATGR0200 PEDH4ATGR0200 PEDL4ATGR0200
225
250
PEDB4ATGR0225
PEDB4ATGR0250
PEDC4ATGR0225
PEDC4ATGR0250
PEDE4ATGR0225
PEDE4ATGR0250
PEDN4ATGR0225
PEDN4ATGR0250
PEDH4ATGR0225
PEDH4ATGR0250
PEDL4ATGR0225
PEDL4ATGR0250
Intro

B
Thermal Magnetic - 100% UL rated - 4 poles(1)
In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. C
Interrupt Rating @ 480V
18kA 25kA 35kA 65kA 100kA 150kA
Line Thermal Magnetic (LTM)   D
125 PEEB4ATTR0125 PEEC4ATTR0125 PEEE4ATTR0125 PEEN4ATTR0125 PEEH4ATTR0125 PEEL4ATTR0125
150 PEEB4ATTR0150 PEEC4ATTR0150 PEEE4ATTR0150 PEEN4ATTR0150 PEEH4ATTR0150 PEEL4ATTR0150
200 PEEB4ATTR0200 PEEC4ATTR0200 PEEE4ATTR0200 PEEN4ATTR0200 PEEH4ATTR0200 PEEL4ATTR0200
225
250
PEEB4ATTR0225
PEEB4ATTR0250
PEEC4ATTR0225
PEEC4ATTR0250
PEEE4ATTR0225
PEEE4ATTR0250
PEEN4ATTR0225
PEEN4ATTR0250
PEEH4ATTR0225
PEEH4ATTR0250
PEEL4ATTR0225
PEEL4ATTR0250 E

G
Generator Thermal Magnetic (GTM)
125 PEEB4ATGR0125 PEEC4ATGR0125 PEEE4ATGR0125 PEEN4ATGR0125 PEEH4ATGR0125 PEEL4ATGR0125
150
200
PEEB4ATGR0150
PEEB4ATGR0200
PEEC4ATGR0150
PEEC4ATGR0200
PEEE4ATGR0150
PEEE4ATGR0200
PEEN4ATGR0150
PEEN4ATGR0200
PEEH4ATGR0150
PEEH4ATGR0200
PEEL4ATGR0150
PEEL4ATGR0200 X
225 PEEB4ATGR0225 PEEC4ATGR0225 PEEE4ATGR0225 PEEN4ATGR0225 PEEH4ATGR0225 PEEL4ATGR0225
250 PEEB4ATGR0250 PEEC4ATGR0250 PEEE4ATGR0250 PEEN4ATGR0250 PEEH4ATGR0250 PEEL4ATGR0250

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.11
GuardEon
25A complete circuit breaker - GuardEon PE150

Global with UL PE150 - 2 poles - 25A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT and I PEAB2ATSB0025 PEAC2ATSB0025 PEAE2ATSB0025 PEAN2ATSB0025 PEAH2ATSB0025 PEAL2ATSB0025
LT, I, and GF PEAB2ATSE0025 PEAC2ATSE0025 PEAE2ATSE0025 PEAN2ATSE0025 PEAH2ATSE0025 PEAL2ATSE0025
I PEAB2ATSF0025 PEAC2ATSF0025 PEAE2ATSF0025 PEAN2ATSF0025 PEAH2ATSF0025 PEAL2ATSF0025
I and GF PEAB2ATSH0025 PEAC2ATSH0025 PEAE2ATSH0025 PEAN2ATSH0025 PEAH2ATSH0025 PEAL2ATSH0025

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB2ATAJ0025 PEAC2ATAJ0025 PEAE2ATAJ0025 PEAN2ATAJ0025 PEAH2ATAJ0025 PEAL2ATAJ0025
LT, ST, I, and GF PEAB2ATAK0025 PEAC2ATAK0025 PEAE2ATAK0025 PEAN2ATAK0025 PEAH2ATAK0025 PEAL2ATAK0025
GuardEon

LT, ST, I, and GF alarm PEAB2ATAL0025 PEAC2ATAL0025 PEAE2ATAL0025 PEAN2ATAL0025 PEAH2ATAL0025 PEAL2ATAL0025
LT, ST, I, and GF (defeatable) PEAB2ATAM0025 PEAC2ATAM0025 PEAE2ATAM0025 PEAN2ATAM0025 PEAH2ATAM0025 PEAL2ATAM0025

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEAB2ATEJ0025 PEAC2ATEJ0025 PEAE2ATEJ0025 PEAN2ATEJ0025 PEAH2ATEJ0025 PEAL2ATEJ0025
LT, ST, I, and GF PEAB2ATEK0025 PEAC2ATEK0025 PEAE2ATEK0025 PEAN2ATEK0025 PEAH2ATEK0025 PEAL2ATEK0025
LT, ST, I, and GF alarm PEAB2ATEL0025 PEAC2ATEL0025 PEAE2ATEL0025 PEAN2ATEL0025 PEAH2ATEL0025 PEAL2ATEL0025
LT, ST, I, and GF (defeatable) PEAB2ATEM0025 PEAC2ATEM0025 PEAE2ATEM0025 PEAN2ATEM0025 PEAH2ATEM0025 PEAL2ATEM0025

Intro Global with UL PE150 - 100% UL rated - 2 poles - 25A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

A 18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT and I PEBB2ATSB0025 PEBC2ATSB0025 PEBE2ATSB0025 PEBN2ATSB0025 PEBH2ATSB0025 PEBL2ATSB0025
B LT, I, and GF
I
PEBB2ATSE0025
PEBB2ATSF0025
PEBC2ATSE0025
PEBC2ATSF0025
PEBE2ATSE0025
PEBE2ATSF0025
PEBN2ATSE0025
PEBN2ATSF0025
PEBH2ATSE0025
PEBH2ATSF0025
PEBL2ATSE0025
PEBL2ATSF0025
I and GF PEBB2ATSH0025 PEBC2ATSH0025 PEBE2ATSH0025 PEBN2ATSH0025 PEBH2ATSH0025 PEBL2ATSH0025

C PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEBB2ATAJ0025 PEBC2ATAJ0025 PEBE2ATAJ0025 PEBN2ATAJ0025 PEBH2ATAJ0025 PEBL2ATAJ0025
LT, ST, I, and GF PEBB2ATAK0025 PEBC2ATAK0025 PEBE2ATAK0025 PEBN2ATAK0025 PEBH2ATAK0025 PEBL2ATAK0025
LT, ST, I, and GF alarm PEBB2ATAL0025 PEBC2ATAL0025 PEBE2ATAL0025 PEBN2ATAL0025 PEBH2ATAL0025 PEBL2ATAL0025
LT, ST, I, and GF (defeatable) PEBB2ATAM0025 PEBC2ATAM0025 PEBE2ATAM0025 PEBN2ATAM0025 PEBH2ATAM0025 PEBL2ATAM0025
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEBB2ATEJ0025 PEBC2ATEJ0025 PEBE2ATEJ0025 PEBN2ATEJ0025 PEBH2ATEJ0025 PEBL2ATEJ0025
LT, ST, I, and GF PEBB2ATEK0025 PEBC2ATEK0025 PEBE2ATEK0025 PEBN2ATEK0025 PEBH2ATEK0025 PEBL2ATEK0025
E LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEBB2ATEL0025
PEBB2ATEM0025
PEBC2ATEL0025
PEBC2ATEM0025
PEBE2ATEL0025
PEBE2ATEM0025
PEBN2ATEL0025
PEBN2ATEM0025
PEBH2ATEL0025
PEBH2ATEM0025
PEBL2ATEL0025
PEBL2ATEM0025

Global with UL PE150 - 3 poles - 25A


F In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
G PremEon S electronic trip units - Tracking Short-Time settings
 
LT and I PEAB3ATSB0025 PEAC3ATSB0025 PEAE3ATSB0025 PEAN3ATSB0025 PEAH3ATSB0025 PEAL3ATSB0025
LT, I, and GF PEAB3ATSE0025 PEAC3ATSE0025 PEAE3ATSE0025 PEAN3ATSE0025 PEAH3ATSE0025 PEAL3ATSE0025

X I
I and GF
PEAB3ATSF0025
PEAB3ATSH0025
PEAC3ATSF0025
PEAC3ATSH0025
PEAE3ATSF0025
PEAE3ATSH0025
PEAN3ATSF0025
PEAN3ATSH0025
PEAH3ATSF0025
PEAH3ATSH0025
PEAL3ATSF0025
PEAL3ATSH0025

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB3ATAJ0025 PEAC3ATAJ0025 PEAE3ATAJ0025 PEAN3ATAJ0025 PEAH3ATAJ0025 PEAL3ATAJ0025
LT, ST, I, and GF PEAB3ATAK0025 PEAC3ATAK0025 PEAE3ATAK0025 PEAN3ATAK0025 PEAH3ATAK0025 PEAL3ATAK0025
LT, ST, I, and GF alarm PEAB3ATAL0025 PEAC3ATAL0025 PEAE3ATAL0025 PEAN3ATAL0025 PEAH3ATAL0025 PEAL3ATAL0025
LT, ST, I, and GF (defeatable) PEAB3ATAM0025 PEAC3ATAM0025 PEAE3ATAM0025 PEAN3ATAM0025 PEAH3ATAM0025 PEAL3ATAM0025

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEAB3ATEJ0025 PEAC3ATEJ0025 PEAE3ATEJ0025 PEAN3ATEJ0025 PEAH3ATEJ0025 PEAL3ATEJ0025
LT, ST, I, and GF PEAB3ATEK0025 PEAC3ATEK0025 PEAE3ATEK0025 PEAN3ATEK0025 PEAH3ATEK0025 PEAL3ATEK0025
LT, ST, I, and GF alarm PEAB3ATEL0025 PEAC3ATEL0025 PEAE3ATEL0025 PEAN3ATEL0025 PEAH3ATEL0025 PEAL3ATEL0025
LT, ST, I, and GF (defeatable) PEAB3ATEM0025 PEAC3ATEM0025 PEAE3ATEM0025 PEAN3ATEM0025 PEAH3ATEM0025 PEAL3ATEM0025

A.12
GuardEon
25A complete circuit breaker - GuardEon PE150

Global with UL PE150 - 100% UL rated - 3 poles - 25A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT and I PEBB3ATSB0025 PEBC3ATSB0025 PEBE3ATSB0025 PEBN3ATSB0025 PEBH3ATSB0025 PEBL3ATSB0025
LT, I, and GF PEBB3ATSE0025 PEBC3ATSE0025 PEBE3ATSE0025 PEBN3ATSE0025 PEBH3ATSE0025 PEBL3ATSE0025
I PEBB3ATSF0025 PEBC3ATSF0025 PEBE3ATSF0025 PEBN3ATSF0025 PEBH3ATSF0025 PEBL3ATSF0025
I and GF PEBB3ATSH0025 PEBC3ATSH0025 PEBE3ATSH0025 PEBN3ATSH0025 PEBH3ATSH0025 PEBL3ATSH0025

PremEon G Current electronic trip units - Fully adjustable settings

Order codes
LT, ST, and I PEBB3ATAJ0025 PEBC3ATAJ0025 PEBE3ATAJ0025 PEBN3ATAJ0025 PEBH3ATAJ0025 PEBL3ATAJ0025
LT, ST, I, and GF PEBB3ATAK0025 PEBC3ATAK0025 PEBE3ATAK0025 PEBN3ATAK0025 PEBH3ATAK0025 PEBL3ATAK0025
LT, ST, I, and GF alarm PEBB3ATAL0025 PEBC3ATAL0025 PEBE3ATAL0025 PEBN3ATAL0025 PEBH3ATAL0025 PEBL3ATAL0025
LT, ST, I, and GF (defeatable) PEBB3ATAM0025 PEBC3ATAM0025 PEBE3ATAM0025 PEBN3ATAM0025 PEBH3ATAM0025 PEBL3ATAM0025

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEBB3ATEJ0025 PEBC3ATEJ0025 PEBE3ATEJ0025 PEBN3ATEJ0025 PEBH3ATEJ0025 PEBL3ATEJ0025
LT, ST, I, and GF PEBB3ATEK0025 PEBC3ATEK0025 PEBE3ATEK0025 PEBN3ATEK0025 PEBH3ATEK0025 PEBL3ATEK0025
LT, ST, I, and GF alarm PEBB3ATEL0025 PEBC3ATEL0025 PEBE3ATEL0025 PEBN3ATEL0025 PEBH3ATEL0025 PEBL3ATEL0025
LT, ST, I, and GF (defeatable) PEBB3ATEM0025 PEBC3ATEM0025 PEBE3ATEM0025 PEBN3ATEM0025 PEBH3ATEM0025 PEBL3ATEM0025

Global with UL PE150 - 4 poles - 25A(1) Intro


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
A
PremEon S electronic trip units - Tracking Short-Time settings
 
LT and I PEAB4ATSB0025 PEAC4ATSB0025 PEAE4ATSB0025 PEAN4ATSB0025 PEAH4ATSB0025 PEAL4ATSB0025
LT, I, and GF
I
PEAB4ATSE0025
PEAB4ATSF0025
PEAC4ATSE0025
PEAC4ATSF0025
PEAE4ATSE0025
PEAE4ATSF0025
PEAN4ATSE0025
PEAN4ATSF0025
PEAH4ATSE0025
PEAH4ATSF0025
PEAL4ATSE0025
PEAL4ATSF0025
B
I and GF PEAB4ATSH0025 PEAC4ATSH0025 PEAE4ATSH0025 PEAN4ATSH0025 PEAH4ATSH0025 PEAL4ATSH0025

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB4ATAJ0025 PEAC4ATAJ0025 PEAE4ATAJ0025 PEAN4ATAJ0025 PEAH4ATAJ0025 PEAL4ATAJ0025
C
LT, ST, I, and GF PEAB4ATAK0025 PEAC4ATAK0025 PEAE4ATAK0025 PEAN4ATAK0025 PEAH4ATAK0025 PEAL4ATAK0025
LT, ST, I, and GF alarm PEAB4ATAL0025 PEAC4ATAL0025 PEAE4ATAL0025 PEAN4ATAL0025 PEAH4ATAL0025 PEAL4ATAL0025
LT, ST, I, and GF (defeatable) PEAB4ATAM0025 PEAC4ATAM0025 PEAE4ATAM0025 PEAN4ATAM0025 PEAH4ATAM0025 PEAL4ATAM0025
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEAB4ATEJ0025 PEAC4ATEJ0025 PEAE4ATEJ0025 PEAN4ATEJ0025 PEAH4ATEJ0025 PEAL4ATEJ0025
LT, ST, I, and GF PEAB4ATEK0025 PEAC4ATEK0025 PEAE4ATEK0025 PEAN4ATEK0025 PEAH4ATEK0025 PEAL4ATEK0025
LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEAB4ATEL0025
PEAB4ATEM0025
PEAC4ATEL0025
PEAC4ATEM0025
PEAE4ATEL0025
PEAE4ATEM0025
PEAN4ATEL0025
PEAN4ATEM0025
PEAH4ATEL0025
PEAH4ATEM0025
PEAL4ATEL0025
PEAL4ATEM0025 E

Global with UL PE150 - 100% UL rated - 4 poles - 25A(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.
F
Interrupt Rating @ 480V
18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
G
LT and I PEBB4ATSB0025 PEBC4ATSB0025 PEBE4ATSB0025 PEBN4ATSB0025 PEBH4ATSB0025 PEBL4ATSB0025
LT, I, and GF PEBB4ATSE0025 PEBC4ATSE0025 PEBE4ATSE0025 PEBN4ATSE0025 PEBH4ATSE0025 PEBL4ATSE0025
I
I and GF
PEBB4ATSF0025
PEBB4ATSH0025
PEBC4ATSF0025
PEBC4ATSH0025
PEBE4ATSF0025
PEBE4ATSH0025
PEBN4ATSF0025
PEBN4ATSH0025
PEBH4ATSF0025
PEBH4ATSH0025
PEBL4ATSF0025
PEBL4ATSH0025 X
PremEon G Current electronic trip units - Fully adjustable settings
LT, ST, and I PEBB4ATAJ0025 PEBC4ATAJ0025 PEBE4ATAJ0025 PEBN4ATAJ0025 PEBH4ATAJ0025 PEBL4ATAJ0025
LT, ST, I, and GF PEBB4ATAK0025 PEBC4ATAK0025 PEBE4ATAK0025 PEBN4ATAK0025 PEBH4ATAK0025 PEBL4ATAK0025
LT, ST, I, and GF alarm PEBB4ATAL0025 PEBC4ATAL0025 PEBE4ATAL0025 PEBN4ATAL0025 PEBH4ATAL0025 PEBL4ATAL0025
LT, ST, I, and GF (defeatable) PEBB4ATAM0025 PEBC4ATAM0025 PEBE4ATAM0025 PEBN4ATAM0025 PEBH4ATAM0025 PEBL4ATAM0025

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEBB4ATEJ0025 PEBC4ATEJ0025 PEBE4ATEJ0025 PEBN4ATEJ0025 PEBH4ATEJ0025 PEBL4ATEJ0025
LT, ST, I, and GF PEBB4ATEK0025 PEBC4ATEK0025 PEBE4ATEK0025 PEBN4ATEK0025 PEBH4ATEK0025 PEBL4ATEK0025
LT, ST, I, and GF alarm PEBB4ATEL0025 PEBC4ATEL0025 PEBE4ATEL0025 PEBN4ATEL0025 PEBH4ATEL0025 PEBL4ATEL0025
LT, ST, I, and GF (defeatable) PEBB4ATEM0025 PEBC4ATEM0025 PEBE4ATEM0025 PEBN4ATEM0025 PEBH4ATEM0025 PEBL4ATEM0025

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.13
GuardEon
60A complete circuit breaker - GuardEon PE150

Global with UL PE150 - 2 poles - 60A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEAB2ATSB0060 PEAC2ATSB0060 PEAE2ATSB0060 PEAN2ATSB0060 PEAH2ATSB0060 PEAL2ATSB0060
LT, ST, I, and GF PEAB2ATSE0060 PEAC2ATSE0060 PEAE2ATSE0060 PEAN2ATSE0060 PEAH2ATSE0060 PEAL2ATSE0060
ST and I PEAB2ATSF0060 PEAC2ATSF0060 PEAE2ATSF0060 PEAN2ATSF0060 PEAH2ATSF0060 PEAL2ATSF0060
ST, I, and GF PEAB2ATSH0060 PEAC2ATSH0060 PEAE2ATSH0060 PEAN2ATSH0060 PEAH2ATSH0060 PEAL2ATSH0060

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB2ATAJ0060 PEAC2ATAJ0060 PEAE2ATAJ0060 PEAN2ATAJ0060 PEAH2ATAJ0060 PEAL2ATAJ0060
LT, ST, I, and GF PEAB2ATAK0060 PEAC2ATAK0060 PEAE2ATAK0060 PEAN2ATAK0060 PEAH2ATAK0060 PEAL2ATAK0060
GuardEon

LT, ST, I, and GF alarm PEAB2ATAL0060 PEAC2ATAL0060 PEAE2ATAL0060 PEAN2ATAL0060 PEAH2ATAL0060 PEAL2ATAL0060
LT, ST, I, and GF (defeatable) PEAB2ATAM0060 PEAC2ATAM0060 PEAE2ATAM0060 PEAN2ATAM0060 PEAH2ATAM0060 PEAL2ATAM0060

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEAB2ATEJ0060 PEAC2ATEJ0060 PEAE2ATEJ0060 PEAN2ATEJ0060 PEAH2ATEJ0060 PEAL2ATEJ0060
LT, ST, I, and GF PEAB2ATEK0060 PEAC2ATEK0060 PEAE2ATEK0060 PEAN2ATEK0060 PEAH2ATEK0060 PEAL2ATEK0060
LT, ST, I, and GF alarm PEAB2ATEL0060 PEAC2ATEL0060 PEAE2ATEL0060 PEAN2ATEL0060 PEAH2ATEL0060 PEAL2ATEL0060
LT, ST, I, and GF (defeatable) PEAB2ATEM0060 PEAC2ATEM0060 PEAE2ATEM0060 PEAN2ATEM0060 PEAH2ATEM0060 PEAL2ATEM0060

Intro Global with UL PE150 - 100% UL rated - 2 poles - 60A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

A 18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEBB2ATSB0060 PEBC2ATSB0060 PEBE2ATSB0060 PEBN2ATSB0060 PEBH2ATSB0060 PEBL2ATSB0060
B LT, ST, I, and GF
ST and I
PEBB2ATSE0060
PEBB2ATSF0060
PEBC2ATSE0060
PEBC2ATSF0060
PEBE2ATSE0060
PEBE2ATSF0060
PEBN2ATSE0060
PEBN2ATSF0060
PEBH2ATSE0060
PEBH2ATSF0060
PEBL2ATSE0060
PEBL2ATSF0060
ST, I, and GF PEBB2ATSH0060 PEBC2ATSH0060 PEBE2ATSH0060 PEBN2ATSH0060 PEBH2ATSH0060 PEBL2ATSH0060

C PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEBB2ATAJ0060 PEBC2ATAJ0060 PEBE2ATAJ0060 PEBN2ATAJ0060 PEBH2ATAJ0060 PEBL2ATAJ0060
LT, ST, I, and GF PEBB2ATAK0060 PEBC2ATAK0060 PEBE2ATAK0060 PEBN2ATAK0060 PEBH2ATAK0060 PEBL2ATAK0060
LT, ST, I, and GF alarm PEBB2ATAL0060 PEBC2ATAL0060 PEBE2ATAL0060 PEBN2ATAL0060 PEBH2ATAL0060 PEBL2ATAL0060
LT, ST, I, and GF (defeatable) PEBB2ATAM0060 PEBC2ATAM0060 PEBE2ATAM0060 PEBN2ATAM0060 PEBH2ATAM0060 PEBL2ATAM0060
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEBB2ATEJ0060 PEBC2ATEJ0060 PEBE2ATEJ0060 PEBN2ATEJ0060 PEBH2ATEJ0060 PEBL2ATEJ0060
LT, ST, I, and GF PEBB2ATEK0060 PEBC2ATEK0060 PEBE2ATEK0060 PEBN2ATEK0060 PEBH2ATEK0060 PEBL2ATEK0060
E LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEBB2ATEL0060
PEBB2ATEM0060
PEBC2ATEL0060
PEBC2ATEM0060
PEBE2ATEL0060
PEBE2ATEM0060
PEBN2ATEL0060
PEBN2ATEM0060
PEBH2ATEL0060
PEBH2ATEM0060
PEBL2ATEL0060
PEBL2ATEM0060

Global with UL PE150 - 3 poles - 60A


F In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
G PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEAB3ATSB0060 PEAC3ATSB0060 PEAE3ATSB0060 PEAN3ATSB0060 PEAH3ATSB0060 PEAL3ATSB0060
LT, ST, I, and GF PEAB3ATSE0060 PEAC3ATSE0060 PEAE3ATSE0060 PEAN3ATSE0060 PEAH3ATSE0060 PEAL3ATSE0060

X ST and I
ST, I, and GF
PEAB3ATSF0060
PEAB3ATSH0060
PEAC3ATSF0060
PEAC3ATSH0060
PEAE3ATSF0060
PEAE3ATSH0060
PEAN3ATSF0060
PEAN3ATSH0060
PEAH3ATSF0060
PEAH3ATSH0060
PEAL3ATSF0060
PEAL3ATSH0060

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB3ATAJ0060 PEAC3ATAJ0060 PEAE3ATAJ0060 PEAN3ATAJ0060 PEAH3ATAJ0060 PEAL3ATAJ0060
LT, ST, I, and GF PEAB3ATAK0060 PEAC3ATAK0060 PEAE3ATAK0060 PEAN3ATAK0060 PEAH3ATAK0060 PEAL3ATAK0060
LT, ST, I, and GF alarm PEAB3ATAL0060 PEAC3ATAL0060 PEAE3ATAL0060 PEAN3ATAL0060 PEAH3ATAL0060 PEAL3ATAL0060
LT, ST, I, and GF (defeatable) PEAB3ATAM0060 PEAC3ATAM0060 PEAE3ATAM0060 PEAN3ATAM0060 PEAH3ATAM0060 PEAL3ATAM0060

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEAB3ATEJ0060 PEAC3ATEJ0060 PEAE3ATEJ0060 PEAN3ATEJ0060 PEAH3ATEJ0060 PEAL3ATEJ0060
LT, ST, I, and GF PEAB3ATEK0060 PEAC3ATEK0060 PEAE3ATEK0060 PEAN3ATEK0060 PEAH3ATEK0060 PEAL3ATEK0060
LT, ST, I, and GF alarm PEAB3ATEL0060 PEAC3ATEL0060 PEAE3ATEL0060 PEAN3ATEL0060 PEAH3ATEL0060 PEAL3ATEL0060
LT, ST, I, and GF (defeatable) PEAB3ATEM0060 PEAC3ATEM0060 PEAE3ATEM0060 PEAN3ATEM0060 PEAH3ATEM0060 PEAL3ATEM0060

A.14
GuardEon
60A complete circuit breaker - GuardEon PE150

Global with UL PE150 - 100% UL rated - 3 poles - 60A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEBB3ATSB0060 PEBC3ATSB0060 PEBE3ATSB0060 PEBN3ATSB0060 PEBH3ATSB0060 PEBL3ATSB0060
LT, ST, I, and GF PEBB3ATSE0060 PEBC3ATSE0060 PEBE3ATSE0060 PEBN3ATSE0060 PEBH3ATSE0060 PEBL3ATSE0060
ST and I PEBB3ATSF0060 PEBC3ATSF0060 PEBE3ATSF0060 PEBN3ATSF0060 PEBH3ATSF0060 PEBL3ATSF0060
ST, I, and GF PEBB3ATSH0060 PEBC3ATSH0060 PEBE3ATSH0060 PEBN3ATSH0060 PEBH3ATSH0060 PEBL3ATSH0060

PremEon G Current electronic trip units - Fully adjustable settings

Order codes
LT, ST, and I PEBB3ATAJ0060 PEBC3ATAJ0060 PEBE3ATAJ0060 PEBN3ATAJ0060 PEBH3ATAJ0060 PEBL3ATAJ0060
LT, ST, I, and GF PEBB3ATAK0060 PEBC3ATAK0060 PEBE3ATAK0060 PEBN3ATAK0060 PEBH3ATAK0060 PEBL3ATAK0060
LT, ST, I, and GF alarm PEBB3ATAL0060 PEBC3ATAL0060 PEBE3ATAL0060 PEBN3ATAL0060 PEBH3ATAL0060 PEBL3ATAL0060
LT, ST, I, and GF (defeatable) PEBB3ATAM0060 PEBC3ATAM0060 PEBE3ATAM0060 PEBN3ATAM0060 PEBH3ATAM0060 PEBL3ATAM0060

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEBB3ATEJ0060 PEBC3ATEJ0060 PEBE3ATEJ0060 PEBN3ATEJ0060 PEBH3ATEJ0060 PEBL3ATEJ0060
LT, ST, I, and GF PEBB3ATEK0060 PEBC3ATEK0060 PEBE3ATEK0060 PEBN3ATEK0060 PEBH3ATEK0060 PEBL3ATEK0060
LT, ST, I, and GF alarm PEBB3ATEL0060 PEBC3ATEL0060 PEBE3ATEL0060 PEBN3ATEL0060 PEBH3ATEL0060 PEBL3ATEL0060
LT, ST, I, and GF (defeatable) PEBB3ATEM0060 PEBC3ATEM0060 PEBE3ATEM0060 PEBN3ATEM0060 PEBH3ATEM0060 PEBL3ATEM0060

Global with UL PE150 - 4 poles - 60A(1) Intro


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
A
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEAB4ATSB0060 PEAC4ATSB0060 PEAE4ATSB0060 PEAN4ATSB0060 PEAH4ATSB0060 PEAL4ATSB0060
LT, ST, I, and GF
ST and I
PEAB4ATSE0060
PEAB4ATSF0060
PEAC4ATSE0060
PEAC4ATSF0060
PEAE4ATSE0060
PEAE4ATSF0060
PEAN4ATSE0060
PEAN4ATSF0060
PEAH4ATSE0060
PEAH4ATSF0060
PEAL4ATSE0060
PEAL4ATSF0060
B
ST, I, and GF PEAB4ATSH0060 PEAC4ATSH0060 PEAE4ATSH0060 PEAN4ATSH0060 PEAH4ATSH0060 PEAL4ATSH0060

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB4ATAJ0060 PEAC4ATAJ0060 PEAE4ATAJ0060 PEAN4ATAJ0060 PEAH4ATAJ0060 PEAL4ATAJ0060
C
LT, ST, I, and GF PEAB4ATAK0060 PEAC4ATAK0060 PEAE4ATAK0060 PEAN4ATAK0060 PEAH4ATAK0060 PEAL4ATAK0060
LT, ST, I, and GF alarm PEAB4ATAL0060 PEAC4ATAL0060 PEAE4ATAL0060 PEAN4ATAL0060 PEAH4ATAL0060 PEAL4ATAL0060
LT, ST, I, and GF (defeatable) PEAB4ATAM0060 PEAC4ATAM0060 PEAE4ATAM0060 PEAN4ATAM0060 PEAH4ATAM0060 PEAL4ATAM0060
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEAB4ATEJ0060 PEAC4ATEJ0060 PEAE4ATEJ0060 PEAN4ATEJ0060 PEAH4ATEJ0060 PEAL4ATEJ0060
LT, ST, I, and GF PEAB4ATEK0060 PEAC4ATEK0060 PEAE4ATEK0060 PEAN4ATEK0060 PEAH4ATEK0060 PEAL4ATEK0060
LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEAB4ATEL0060
PEAB4ATEM0060
PEAC4ATEL0060
PEAC4ATEM0060
PEAE4ATEL0060
PEAE4ATEM0060
PEAN4ATEL0060
PEAN4ATEM0060
PEAH4ATEL0060
PEAH4ATEM0060
PEAL4ATEL0060
PEAL4ATEM0060 E

Global with UL PE150 - 100% UL rated - 4 poles - 60A(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.
F
Interrupt Rating @ 480V
18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
G
LT, ST, and I PEBB4ATSB0060 PEBC4ATSB0060 PEBE4ATSB0060 PEBN4ATSB0060 PEBH4ATSB0060 PEBL4ATSB0060
LT, ST, I, and GF PEBB4ATSE0060 PEBC4ATSE0060 PEBE4ATSE0060 PEBN4ATSE0060 PEBH4ATSE0060 PEBL4ATSE0060
ST and I
ST, I, and GF
PEBB4ATSF0060
PEBB4ATSH0060
PEBC4ATSF0060
PEBC4ATSH0060
PEBE4ATSF0060
PEBE4ATSH0060
PEBN4ATSF0060
PEBN4ATSH0060
PEBH4ATSF0060
PEBH4ATSH0060
PEBL4ATSF0060
PEBL4ATSH0060 X
PremEon G Current electronic trip units - Fully adjustable settings
LT, ST, and I PEBB4ATAJ0060 PEBC4ATAJ0060 PEBE4ATAJ0060 PEBN4ATAJ0060 PEBH4ATAJ0060 PEBL4ATAJ0060
LT, ST, I, and GF PEBB4ATAK0060 PEBC4ATAK0060 PEBE4ATAK0060 PEBN4ATAK0060 PEBH4ATAK0060 PEBL4ATAK0060
LT, ST, I, and GF alarm PEBB4ATAL0060 PEBC4ATAL0060 PEBE4ATAL0060 PEBN4ATAL0060 PEBH4ATAL0060 PEBL4ATAL0060
LT, ST, I, and GF (defeatable) PEBB4ATAM0060 PEBC4ATAM0060 PEBE4ATAM0060 PEBN4ATAM0060 PEBH4ATAM0060 PEBL4ATAM0060

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEBB4ATEJ0060 PEBC4ATEJ0060 PEBE4ATEJ0060 PEBN4ATEJ0060 PEBH4ATEJ0060 PEBL4ATEJ0060
LT, ST, I, and GF PEBB4ATEK0060 PEBC4ATEK0060 PEBE4ATEK0060 PEBN4ATEK0060 PEBH4ATEK0060 PEBL4ATEK0060
LT, ST, I, and GF alarm PEBB4ATEL0060 PEBC4ATEL0060 PEBE4ATEL0060 PEBN4ATEL0060 PEBH4ATEL0060 PEBL4ATEL0060
LT, ST, I, and GF (defeatable) PEBB4ATEM0060 PEBC4ATEM0060 PEBE4ATEM0060 PEBN4ATEM0060 PEBH4ATEM0060 PEBL4ATEM0060

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.15
GuardEon
125A complete circuit breaker - GuardEon PE150

Global with UL PE150 - 2 poles - 125A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEAB2ATSB0125 PEAC2ATSB0125 PEAE2ATSB0125 PEAN2ATSB0125 PEAH2ATSB0125 PEAL2ATSB0125
LT, ST, I, and GF PEAB2ATSE0125 PEAC2ATSE0125 PEAE2ATSE0125 PEAN2ATSE0125 PEAH2ATSE0125 PEAL2ATSE0125
ST and I PEAB2ATSF0125 PEAC2ATSF0125 PEAE2ATSF0125 PEAN2ATSF0125 PEAH2ATSF0125 PEAL2ATSF0125
ST, I, and GF PEAB2ATSH0125 PEAC2ATSH0125 PEAE2ATSH0125 PEAN2ATSH0125 PEAH2ATSH0125 PEAL2ATSH0125

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB2ATAJ0125 PEAC2ATAJ0125 PEAE2ATAJ0125 PEAN2ATAJ0125 PEAH2ATAJ0125 PEAL2ATAJ0125
LT, ST, I, and GF PEAB2ATAK0125 PEAC2ATAK0125 PEAE2ATAK0125 PEAN2ATAK0125 PEAH2ATAK0125 PEAL2ATAK0125
GuardEon

LT, ST, I, and GF alarm PEAB2ATAL0125 PEAC2ATAL0125 PEAE2ATAL0125 PEAN2ATAL0125 PEAH2ATAL0125 PEAL2ATAL0125
LT, ST, I, and GF (defeatable) PEAB2ATAM0125 PEAC2ATAM0125 PEAE2ATAM0125 PEAN2ATAM0125 PEAH2ATAM0125 PEAL2ATAM0125

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEAB2ATEJ0125 PEAC2ATEJ0125 PEAE2ATEJ0125 PEAN2ATEJ0125 PEAH2ATEJ0125 PEAL2ATEJ0125
LT, ST, I, and GF PEAB2ATEK0125 PEAC2ATEK0125 PEAE2ATEK0125 PEAN2ATEK0125 PEAH2ATEK0125 PEAL2ATEK0125
LT, ST, I, and GF alarm PEAB2ATEL0125 PEAC2ATEL0125 PEAE2ATEL0125 PEAN2ATEL0125 PEAH2ATEL0125 PEAL2ATEL0125
LT, ST, I, and GF (defeatable) PEAB2ATEM0125 PEAC2ATEM0125 PEAE2ATEM0125 PEAN2ATEM0125 PEAH2ATEM0125 PEAL2ATEM0125

Intro Global with UL PE150 - 100% UL rated - 2 poles - 125A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

A 18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEBB2ATSB0125 PEBC2ATSB0125 PEBE2ATSB0125 PEBN2ATSB0125 PEBH2ATSB0125 PEBL2ATSB0125
B LT, ST, I, and GF
ST and I
PEBB2ATSE0125
PEBB2ATSF0125
PEBC2ATSE0125
PEBC2ATSF0125
PEBE2ATSE0125
PEBE2ATSF0125
PEBN2ATSE0125
PEBN2ATSF0125
PEBH2ATSE0125
PEBH2ATSF0125
PEBL2ATSE0125
PEBL2ATSF0125
ST, I, and GF PEBB2ATSH0125 PEBC2ATSH0125 PEBE2ATSH0125 PEBN2ATSH0125 PEBH2ATSH0125 PEBL2ATSH0125

C PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEBB2ATAJ0125 PEBC2ATAJ0125 PEBE2ATAJ0125 PEBN2ATAJ0125 PEBH2ATAJ0125 PEBL2ATAJ0125
LT, ST, I, and GF PEBB2ATAK0125 PEBC2ATAK0125 PEBE2ATAK0125 PEBN2ATAK0125 PEBH2ATAK0125 PEBL2ATAK0125
LT, ST, I, and GF alarm PEBB2ATAL0125 PEBC2ATAL0125 PEBE2ATAL0125 PEBN2ATAL0125 PEBH2ATAL0125 PEBL2ATAL0125
LT, ST, I, and GF (defeatable) PEBB2ATAM0125 PEBC2ATAM0125 PEBE2ATAM0125 PEBN2ATAM0125 PEBH2ATAM0125 PEBL2ATAM0125
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEBB2ATEJ0125 PEBC2ATEJ0125 PEBE2ATEJ0125 PEBN2ATEJ0125 PEBH2ATEJ0125 PEBL2ATEJ0125
LT, ST, I, and GF PEBB2ATEK0125 PEBC2ATEK0125 PEBE2ATEK0125 PEBN2ATEK0125 PEBH2ATEK0125 PEBL2ATEK0125
E LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEBB2ATEL0125
PEBB2ATEM0125
PEBC2ATEL0125
PEBC2ATEM0125
PEBE2ATEL0125
PEBE2ATEM0125
PEBN2ATEL0125
PEBN2ATEM0125
PEBH2ATEL0125
PEBH2ATEM0125
PEBL2ATEL0125
PEBL2ATEM0125

F Global with UL PE150 - 3 poles - 125A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V

G 18kA 25kA
PremEon S electronic trip units - Tracking Short-Time settings

35kA 65kA

100kA 150kA

LT, ST, and I PEAB3ATSB0125 PEAC3ATSB0125 PEAE3ATSB0125 PEAN3ATSB0125 PEAH3ATSB0125 PEAL3ATSB0125


LT, ST, I, and GF PEAB3ATSE0125 PEAC3ATSE0125 PEAE3ATSE0125 PEAN3ATSE0125 PEAH3ATSE0125 PEAL3ATSE0125
X ST and I
ST, I, and GF
PEAB3ATSF0125
PEAB3ATSH0125
PEAC3ATSF0125
PEAC3ATSH0125
PEAE3ATSF0125
PEAE3ATSH0125
PEAN3ATSF0125
PEAN3ATSH0125
PEAH3ATSF0125
PEAH3ATSH0125
PEAL3ATSF0125
PEAL3ATSH0125

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB3ATAJ0125 PEAC3ATAJ0125 PEAE3ATAJ0125 PEAN3ATAJ0125 PEAH3ATAJ0125 PEAL3ATAJ0125
LT, ST, I, and GF PEAB3ATAK0125 PEAC3ATAK0125 PEAE3ATAK0125 PEAN3ATAK0125 PEAH3ATAK0125 PEAL3ATAK0125
LT, ST, I, and GF alarm PEAB3ATAL0125 PEAC3ATAL0125 PEAE3ATAL0125 PEAN3ATAL0125 PEAH3ATAL0125 PEAL3ATAL0125
LT, ST, I, and GF (defeatable) PEAB3ATAM0125 PEAC3ATAM0125 PEAE3ATAM0125 PEAN3ATAM0125 PEAH3ATAM0125 PEAL3ATAM0125

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEAB3ATEJ0125 PEAC3ATEJ0125 PEAE3ATEJ0125 PEAN3ATEJ0125 PEAH3ATEJ0125 PEAL3ATEJ0125
LT, ST, I, and GF PEAB3ATEK0125 PEAC3ATEK0125 PEAE3ATEK0125 PEAN3ATEK0125 PEAH3ATEK0125 PEAL3ATEK0125
LT, ST, I, and GF alarm PEAB3ATEL0125 PEAC3ATEL0125 PEAE3ATEL0125 PEAN3ATEL0125 PEAH3ATEL0125 PEAL3ATEL0125
LT, ST, I, and GF (defeatable) PEAB3ATEM0125 PEAC3ATEM0125 PEAE3ATEM0125 PEAN3ATEM0125 PEAH3ATEM0125 PEAL3ATEM0125

A.16
GuardEon
125A complete circuit breaker - GuardEon PE150

Global with UL PE150 - 100% UL rated - 3 poles - 125A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEBB3ATSB0125 PEBC3ATSB0125 PEBE3ATSB0125 PEBN3ATSB0125 PEBH3ATSB0125 PEBL3ATSB0125
LT, ST, I, and GF PEBB3ATSE0125 PEBC3ATSE0125 PEBE3ATSE0125 PEBN3ATSE0125 PEBH3ATSE0125 PEBL3ATSE0125
ST and I PEBB3ATSF0125 PEBC3ATSF0125 PEBE3ATSF0125 PEBN3ATSF0125 PEBH3ATSF0125 PEBL3ATSF0125
ST, I, and GF PEBB3ATSH0125 PEBC3ATSH0125 PEBE3ATSH0125 PEBN3ATSH0125 PEBH3ATSH0125 PEBL3ATSH0125

PremEon G Current electronic trip units - Fully adjustable settings

Order codes
LT, ST, and I PEBB3ATAJ0125 PEBC3ATAJ0125 PEBE3ATAJ0125 PEBN3ATAJ0125 PEBH3ATAJ0125 PEBL3ATAJ0125
LT, ST, I, and GF PEBB3ATAK0125 PEBC3ATAK0125 PEBE3ATAK0125 PEBN3ATAK0125 PEBH3ATAK0125 PEBL3ATAK0125
LT, ST, I, and GF alarm PEBB3ATAL0125 PEBC3ATAL0125 PEBE3ATAL0125 PEBN3ATAL0125 PEBH3ATAL0125 PEBL3ATAL0125
LT, ST, I, and GF (defeatable) PEBB3ATAM0125 PEBC3ATAM0125 PEBE3ATAM0125 PEBN3ATAM0125 PEBH3ATAM0125 PEBL3ATAM0125

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEBB3ATEJ0125 PEBC3ATEJ0125 PEBE3ATEJ0125 PEBN3ATEJ0125 PEBH3ATEJ0125 PEBL3ATEJ0125
LT, ST, I, and GF PEBB3ATEK0125 PEBC3ATEK0125 PEBE3ATEK0125 PEBN3ATEK0125 PEBH3ATEK0125 PEBL3ATEK0125
LT, ST, I, and GF alarm PEBB3ATEL0125 PEBC3ATEL0125 PEBE3ATEL0125 PEBN3ATEL0125 PEBH3ATEL0125 PEBL3ATEL0125
LT, ST, I, and GF (defeatable) PEBB3ATEM0125 PEBC3ATEM0125 PEBE3ATEM0125 PEBN3ATEM0125 PEBH3ATEM0125 PEBL3ATEM0125

Global with UL PE150 - 100% UL rated - 4 poles - 125A(1) Intro


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
A
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEBB4ATSB0125 PEBC4ATSB0125 PEBE4ATSB0125 PEBN4ATSB0125 PEBH4ATSB0125 PEBL4ATSB0125
LT, ST, I, and GF
ST and I
PEBB4ATSE0125
PEBB4ATSF0125
PEBC4ATSE0125
PEBC4ATSF0125
PEBE4ATSE0125
PEBE4ATSF0125
PEBN4ATSE0125
PEBN4ATSF0125
PEBH4ATSE0125
PEBH4ATSF0125
PEBL4ATSE0125
PEBL4ATSF0125
B
ST, I, and GF PEBB4ATSH0125 PEBC4ATSH0125 PEBE4ATSH0125 PEBN4ATSH0125 PEBH4ATSH0125 PEBL4ATSH0125

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEBB4ATAJ0125 PEBC4ATAJ0125 PEBE4ATAJ0125 PEBN4ATAJ0125 PEBH4ATAJ0125 PEBL4ATAJ0125
C
LT, ST, I, and GF PEBB4ATAK0125 PEBC4ATAK0125 PEBE4ATAK0125 PEBN4ATAK0125 PEBH4ATAK0125 PEBL4ATAK0125
LT, ST, I, and GF alarm PEBB4ATAL0125 PEBC4ATAL0125 PEBE4ATAL0125 PEBN4ATAL0125 PEBH4ATAL0125 PEBL4ATAL0125
LT, ST, I, and GF (defeatable) PEBB4ATAM0125 PEBC4ATAM0125 PEBE4ATAM0125 PEBN4ATAM0125 PEBH4ATAM0125 PEBL4ATAM0125
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEBB4ATEJ0125 PEBC4ATEJ0125 PEBE4ATEJ0125 PEBN4ATEJ0125 PEBH4ATEJ0125 PEBL4ATEJ0125
LT, ST, I, and GF PEBB4ATEK0125 PEBC4ATEK0125 PEBE4ATEK0125 PEBN4ATEK0125 PEBH4ATEK0125 PEBL4ATEK0125
LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEBB4ATEL0125
PEBB4ATEM0125
PEBC4ATEL0125
PEBC4ATEM0125
PEBE4ATEL0125
PEBE4ATEM0125
PEBN4ATEL0125
PEBN4ATEM0125
PEBH4ATEL0125
PEBH4ATEM0125
PEBL4ATEL0125
PEBL4ATEM0125 E

Global with UL PE150 - 4 poles - 125A(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.
F
Interrupt Rating @ 480V
18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
G
LT, ST, and I PEAB4ATSB0125 PEAC4ATSB0125 PEAE4ATSB0125 PEAN4ATSB0125 PEAH4ATSB0125 PEAL4ATSB0125
LT, ST, I, and GF PEAB4ATSE0125 PEAC4ATSE0125 PEAE4ATSE0125 PEAN4ATSE0125 PEAH4ATSE0125 PEAL4ATSE0125
ST and I
ST, I, and GF
PEAB4ATSF0125
PEAB4ATSH0125
PEAC4ATSF0125
PEAC4ATSH0125
PEAE4ATSF0125
PEAE4ATSH0125
PEAN4ATSF0125
PEAN4ATSH0125
PEAH4ATSF0125
PEAH4ATSH0125
PEAL4ATSF0125
PEAL4ATSH0125 X
PremEon G Current electronic trip units - Fully adjustable settings
LT, ST, and I PEAB4ATAJ0125 PEAC4ATAJ0125 PEAE4ATAJ0125 PEAN4ATAJ0125 PEAH4ATAJ0125 PEAL4ATAJ0125
LT, ST, I, and GF PEAB4ATAK0125 PEAC4ATAK0125 PEAE4ATAK0125 PEAN4ATAK0125 PEAH4ATAK0125 PEAL4ATAK0125
LT, ST, I, and GF alarm PEAB4ATAL0125 PEAC4ATAL0125 PEAE4ATAL0125 PEAN4ATAL0125 PEAH4ATAL0125 PEAL4ATAL0125
LT, ST, I, and GF (defeatable) PEAB4ATAM0125 PEAC4ATAM0125 PEAE4ATAM0125 PEAN4ATAM0125 PEAH4ATAM0125 PEAL4ATAM0125

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEAB4ATEJ0125 PEAC4ATEJ0125 PEAE4ATEJ0125 PEAN4ATEJ0125 PEAH4ATEJ0125 PEAL4ATEJ0125
LT, ST, I, and GF PEAB4ATEK0125 PEAC4ATEK0125 PEAE4ATEK0125 PEAN4ATEK0125 PEAH4ATEK0125 PEAL4ATEK0125
LT, ST, I, and GF alarm PEAB4ATEL0125 PEAC4ATEL0125 PEAE4ATEL0125 PEAN4ATEL0125 PEAH4ATEL0125 PEAL4ATEL0125
LT, ST, I, and GF (defeatable) PEAB4ATEM0125 PEAC4ATEM0125 PEAE4ATEM0125 PEAN4ATEM0125 PEAH4ATEM0125 PEAL4ATEM0125

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.17
GuardEon
125A complete circuit breaker - GuardEon PE250

Global with UL PE250 - 2 poles - 125A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEDB2ATSB0125 PEDC2ATSB0125 PEDE2ATSB0125 PEDN2ATSB0125 PEDH2ATSB0125 PEDL2ATSB0125
LT, ST, I, and GF PEDB2ATSE0125 PEDC2ATSE0125 PEDE2ATSE0125 PEDN2ATSE0125 PEDH2ATSE0125 PEDL2ATSE0125
ST and I PEDB2ATSF0125 PEDC2ATSF0125 PEDE2ATSF0125 PEDN2ATSF0125 PEDH2ATSF0125 PEDL2ATSF0125
ST, I, and GF PEDB2ATSH0125 PEDC2ATSH0125 PEDE2ATSH0125 PEDN2ATSH0125 PEDH2ATSH0125 PEDL2ATSH0125

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEDB2ATAJ0125 PEDC2ATAJ0125 PEDE2ATAJ0125 PEDN2ATAJ0125 PEDH2ATAJ0125 PEDL2ATAJ0125
LT, ST, I, and GF PEDB2ATAK0125 PEDC2ATAK0125 PEDE2ATAK0125 PEDN2ATAK0125 PEDH2ATAK0125 PEDL2ATAK0125
GuardEon

LT, ST, I, and GF alarm PEDB2ATAL0125 PEDC2ATAL0125 PEDE2ATAL0125 PEDN2ATAL0125 PEDH2ATAL0125 PEDL2ATAL0125
LT, ST, I, and GF (defeatable) PEDB2ATAM0125 PEDC2ATAM0125 PEDE2ATAM0125 PEDN2ATAM0125 PEDH2ATAM0125 PEDL2ATAM0125

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEDB2ATEJ0125 PEDC2ATEJ0125 PEDE2ATEJ0125 PEDN2ATEJ0125 PEDH2ATEJ0125 PEDL2ATEJ0125
LT, ST, I, and GF PEDB2ATEK0125 PEDC2ATEK0125 PEDE2ATEK0125 PEDN2ATEK0125 PEDH2ATEK0125 PEDL2ATEK0125
LT, ST, I, and GF alarm PEDB2ATEL0125 PEDC2ATEL0125 PEDE2ATEL0125 PEDN2ATEL0125 PEDH2ATEL0125 PEDL2ATEL0125
LT, ST, I, and GF (defeatable) PEDB2ATEM0125 PEDC2ATEM0125 PEDE2ATEM0125 PEDN2ATEM0125 PEDH2ATEM0125 PEDL2ATEM0125

Intro Global with UL PE250 - 100% UL rated - 2 poles - 125A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


A 18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEEB2ATSB0125 PEEC2ATSB0125 PEEE2ATSB0125 PEEN2ATSB0125 PEEH2ATSB0125 PEEL2ATSB0125
B LT, ST, I, and GF
ST and I
PEEB2ATSE0125
PEEB2ATSF0125
PEEC2ATSE0125
PEEC2ATSF0125
PEEE2ATSE0125
PEEE2ATSF0125
PEEN2ATSE0125
PEEN2ATSF0125
PEEH2ATSE0125
PEEH2ATSF0125
PEEL2ATSE0125
PEEL2ATSF0125
ST, I, and GF PEEB2ATSH0125 PEEC2ATSH0125 PEEE2ATSH0125 PEEN2ATSH0125 PEEH2ATSH0125 PEEL2ATSH0125

PremEon G Current electronic trip units - Fully adjustable settings


C LT, ST, and I PEEB2ATAJ0125 PEEC2ATAJ0125 PEEE2ATAJ0125 PEEN2ATAJ0125 PEEH2ATAJ0125 PEEL2ATAJ0125
LT, ST, I, and GF PEEB2ATAK0125 PEEC2ATAK0125 PEEE2ATAK0125 PEEN2ATAK0125 PEEH2ATAK0125 PEEL2ATAK0125
LT, ST, I, and GF alarm PEEB2ATAL0125 PEEC2ATAL0125 PEEE2ATAL0125 PEEN2ATAL0125 PEEH2ATAL0125 PEEL2ATAL0125
LT, ST, I, and GF (defeatable) PEEB2ATAM0125 PEEC2ATAM0125 PEEE2ATAM0125 PEEN2ATAM0125 PEEH2ATAM0125 PEEL2ATAM0125
D PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEEB2ATEJ0125 PEEC2ATEJ0125 PEEE2ATEJ0125 PEEN2ATEJ0125 PEEH2ATEJ0125 PEEL2ATEJ0125
LT, ST, I, and GF PEEB2ATEK0125 PEEC2ATEK0125 PEEE2ATEK0125 PEEN2ATEK0125 PEEH2ATEK0125 PEEL2ATEK0125

E LT, ST, I, and GF alarm


LT, ST, I, and GF (defeatable)
PEEB2ATEL0125
PEEB2ATEM0125
PEEC2ATEL0125
PEEC2ATEM0125
PEEE2ATEL0125
PEEE2ATEM0125
PEEN2ATEL0125
PEEN2ATEM0125
PEEH2ATEL0125
PEEH2ATEM0125
PEEL2ATEL0125
PEEL2ATEM0125

Global with UL PE250 - 3 poles - 125A


F In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
G PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEDB3ATSB0125 PEDC3ATSB0125 PEDE3ATSB0125 PEDN3ATSB0125 PEDH3ATSB0125 PEDL3ATSB0125
LT, ST, I, and GF PEDB3ATSE0125 PEDC3ATSE0125 PEDE3ATSE0125 PEDN3ATSE0125 PEDH3ATSE0125 PEDL3ATSE0125
ST and I PEDB3ATSF0125 PEDC3ATSF0125 PEDE3ATSF0125 PEDN3ATSF0125 PEDH3ATSF0125 PEDL3ATSF0125
X ST, I, and GF PEDB3ATSH0125 PEDC3ATSH0125 PEDE3ATSH0125 PEDN3ATSH0125 PEDH3ATSH0125 PEDL3ATSH0125

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEDB3ATAJ0125 PEDC3ATAJ0125 PEDE3ATAJ0125 PEDN3ATAJ0125 PEDH3ATAJ0125 PEDL3ATAJ0125
LT, ST, I, and GF PEDB3ATAK0125 PEDC3ATAK0125 PEDE3ATAK0125 PEDN3ATAK0125 PEDH3ATAK0125 PEDL3ATAK0125
LT, ST, I, and GF alarm PEDB3ATAL0125 PEDC3ATAL0125 PEDE3ATAL0125 PEDN3ATAL0125 PEDH3ATAL0125 PEDL3ATAL0125
LT, ST, I, and GF (defeatable) PEDB3ATAM0125 PEDC3ATAM0125 PEDE3ATAM0125 PEDN3ATAM0125 PEDH3ATAM0125 PEDL3ATAM0125

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEDB3ATEJ0125 PEDC3ATEJ0125 PEDE3ATEJ0125 PEDN3ATEJ0125 PEDH3ATEJ0125 PEDL3ATEJ0125
LT, ST, I, and GF PEDB3ATEK0125 PEDC3ATEK0125 PEDE3ATEK0125 PEDN3ATEK0125 PEDH3ATEK0125 PEDL3ATEK0125
LT, ST, I, and GF alarm PEDB3ATEL0125 PEDC3ATEL0125 PEDE3ATEL0125 PEDN3ATEL0125 PEDH3ATEL0125 PEDL3ATEL0125
LT, ST, I, and GF (defeatable) PEDB3ATEM0125 PEDC3ATEM0125 PEDE3ATEM0125 PEDN3ATEM0125 PEDH3ATEM0125 PEDL3ATEM0125

A.18
GuardEon
125A complete circuit breaker - GuardEon PE250

Global with UL PE250 - 100% UL rated - 3 poles - 125A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEEB3ATSB0125 PEEC3ATSB0125 PEEE3ATSB0125 PEEN3ATSB0125 PEEH3ATSB0125 PEEL3ATSB0125
LT, ST, I, and GF PEEB3ATSE0125 PEEC3ATSE0125 PEEE3ATSE0125 PEEN3ATSE0125 PEEH3ATSE0125 PEEL3ATSE0125
ST and I PEEB3ATSF0125 PEEC3ATSF0125 PEEE3ATSF0125 PEEN3ATSF0125 PEEH3ATSF0125 PEEL3ATSF0125
ST, I, and GF PEEB3ATSH0125 PEEC3ATSH0125 PEEE3ATSH0125 PEEN3ATSH0125 PEEH3ATSH0125 PEEL3ATSH0125

PremEon G Current electronic trip units - Fully adjustable settings

Order codes
LT, ST, and I PEEB3ATAJ0125 PEEC3ATAJ0125 PEEE3ATAJ0125 PEEN3ATAJ0125 PEEH3ATAJ0125 PEEL3ATAJ0125
LT, ST, I, and GF PEEB3ATAK0125 PEEC3ATAK0125 PEEE3ATAK0125 PEEN3ATAK0125 PEEH3ATAK0125 PEEL3ATAK0125
LT, ST, I, and GF alarm PEEB3ATAL0125 PEEC3ATAL0125 PEEE3ATAL0125 PEEN3ATAL0125 PEEH3ATAL0125 PEEL3ATAL0125
LT, ST, I, and GF (defeatable) PEEB3ATAM0125 PEEC3ATAM0125 PEEE3ATAM0125 PEEN3ATAM0125 PEEH3ATAM0125 PEEL3ATAM0125

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEEB3ATEJ0125 PEEC3ATEJ0125 PEEE3ATEJ0125 PEEN3ATEJ0125 PEEH3ATEJ0125 PEEL3ATEJ0125
LT, ST, I, and GF PEEB3ATEK0125 PEEC3ATEK0125 PEEE3ATEK0125 PEEN3ATEK0125 PEEH3ATEK0125 PEEL3ATEK0125
LT, ST, I, and GF alarm PEEB3ATEL0125 PEEC3ATEL0125 PEEE3ATEL0125 PEEN3ATEL0125 PEEH3ATEL0125 PEEL3ATEL0125
LT, ST, I, and GF (defeatable) PEEB3ATEM0125 PEEC3ATEM0125 PEEE3ATEM0125 PEEN3ATEM0125 PEEH3ATEM0125 PEEL3ATEM0125

Global with UL PE250 - 4 poles - 125A(1) Intro


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
A
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEDB4ATSB0125 PEDC4ATSB0125 PEDE4ATSB0125 PEDN4ATSB0125 PEDH4ATSB0125 PEDL4ATSB0125
LT, ST, I, and GF
ST and I
PEDB4ATSE0125
PEDB4ATSF0125
PEDC4ATSE0125
PEDC4ATSF0125
PEDE4ATSE0125
PEDE4ATSF0125
PEDN4ATSE0125
PEDN4ATSF0125
PEDH4ATSE0125
PEDH4ATSF0125
PEDL4ATSE0125
PEDL4ATSF0125
B
ST, I, and GF PEDB4ATSH0125 PEDC4ATSH0125 PEDE4ATSH0125 PEDN4ATSH0125 PEDH4ATSH0125 PEDL4ATSH0125

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEDB4ATAJ0125 PEDC4ATAJ0125 PEDE4ATAJ0125 PEDN4ATAJ0125 PEDH4ATAJ0125 PEDL4ATAJ0125
C
LT, ST, I, and GF PEDB4ATAK0125 PEDC4ATAK0125 PEDE4ATAK0125 PEDN4ATAK0125 PEDH4ATAK0125 PEDL4ATAK0125
LT, ST, I, and GF alarm PEDB4ATAL0125 PEDC4ATAL0125 PEDE4ATAL0125 PEDN4ATAL0125 PEDH4ATAL0125 PEDL4ATAL0125
LT, ST, I, and GF (defeatable) PEDB4ATAM0125 PEDC4ATAM0125 PEDE4ATAM0125 PEDN4ATAM0125 PEDH4ATAM0125 PEDL4ATAM0125
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEDB4ATEJ0125 PEDC4ATEJ0125 PEDE4ATEJ0125 PEDN4ATEJ0125 PEDH4ATEJ0125 PEDL4ATEJ0125
LT, ST, I, and GF PEDB4ATEK0125 PEDC4ATEK0125 PEDE4ATEK0125 PEDN4ATEK0125 PEDH4ATEK0125 PEDL4ATEK0125
LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEDB4ATEL0125
PEDB4ATEM0125
PEDC4ATEL0125
PEDC4ATEM0125
PEDE4ATEL0125
PEDE4ATEM0125
PEDN4ATEL0125
PEDN4ATEM0125
PEDH4ATEL0125
PEDH4ATEM0125
PEDL4ATEL0125
PEDL4ATEM0125 E

Global with UL PE250 - 100% UL rated - 4 poles - 125A(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.
F
Interrupt Rating @ 480V
18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
G
LT, ST, and I PEEB4ATSB0125 PEEC4ATSB0125 PEEE4ATSB0125 PEEN4ATSB0125 PEEH4ATSB0125 PEEL4ATSB0125
LT, ST, I, and GF PEEB4ATSE0125 PEEC4ATSE0125 PEEE4ATSE0125 PEEN4ATSE0125 PEEH4ATSE0125 PEEL4ATSE0125
ST and I
ST, I, and GF
PEEB4ATSF0125
PEEB4ATSH0125
PEEC4ATSF0125
PEEC4ATSH0125
PEEE4ATSF0125
PEEE4ATSH0125
PEEN4ATSF0125
PEEN4ATSH0125
PEEH4ATSF0125
PEEH4ATSH0125
PEEL4ATSF0125
PEEL4ATSH0125 X
PremEon G Current electronic trip units - Fully adjustable settings
LT, ST, and I PEEB4ATAJ0125 PEEC4ATAJ0125 PEEE4ATAJ0125 PEEN4ATAJ0125 PEEH4ATAJ0125 PEEL4ATAJ0125
LT, ST, I, and GF PEEB4ATAK0125 PEEC4ATAK0125 PEEE4ATAK0125 PEEN4ATAK0125 PEEH4ATAK0125 PEEL4ATAK0125
LT, ST, I, and GF alarm PEEB4ATAL0125 PEEC4ATAL0125 PEEE4ATAL0125 PEEN4ATAL0125 PEEH4ATAL0125 PEEL4ATAL0125
LT, ST, I, and GF (defeatable) PEEB4ATAM0125 PEEC4ATAM0125 PEEE4ATAM0125 PEEN4ATAM0125 PEEH4ATAM0125 PEEL4ATAM0125

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEEB4ATEJ0125 PEEC4ATEJ0125 PEEE4ATEJ0125 PEEN4ATEJ0125 PEEH4ATEJ0125 PEEL4ATEJ0125
LT, ST, I, and GF PEEB4ATEK0125 PEEC4ATEK0125 PEEE4ATEK0125 PEEN4ATEK0125 PEEH4ATEK0125 PEEL4ATEK0125
LT, ST, I, and GF alarm PEEB4ATEL0125 PEEC4ATEL0125 PEEE4ATEL0125 PEEN4ATEL0125 PEEH4ATEL0125 PEEL4ATEL0125
LT, ST, I, and GF (defeatable) PEEB4ATEM0125 PEEC4ATEM0125 PEEE4ATEM0125 PEEN4ATEM0125 PEEH4ATEM0125 PEEL4ATEM0125

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.19
GuardEon
150A complete circuit breaker - GuardEon PE150

Global with UL PE150 - 2 poles - 150A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEAB2ATSB0150 PEAC2ATSB0150 PEAE2ATSB0150 PEAN2ATSB0150 PEAH2ATSB0150 PEAL2ATSB0150
LT, ST, I, and GF PEAB2ATSE0150 PEAC2ATSE0150 PEAE2ATSE0150 PEAN2ATSE0150 PEAH2ATSE0150 PEAL2ATSE0150
ST and I PEAB2ATSF0150 PEAC2ATSF0150 PEAE2ATSF0150 PEAN2ATSF0150 PEAH2ATSF0150 PEAL2ATSF0150
ST, I, and GF PEAB2ATSH0150 PEAC2ATSH0150 PEAE2ATSH0150 PEAN2ATSH0150 PEAH2ATSH0150 PEAL2ATSH0150

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB2ATAJ0150 PEAC2ATAJ0150 PEAE2ATAJ0150 PEAN2ATAJ0150 PEAH2ATAJ0150 PEAL2ATAJ0150
LT, ST, I, and GF PEAB2ATAK0150 PEAC2ATAK0150 PEAE2ATAK0150 PEAN2ATAK0150 PEAH2ATAK0150 PEAL2ATAK0150
GuardEon

LT, ST, I, and GF alarm PEAB2ATAL0150 PEAC2ATAL0150 PEAE2ATAL0150 PEAN2ATAL0150 PEAH2ATAL0150 PEAL2ATAL0150
LT, ST, I, and GF (defeatable) PEAB2ATAM0150 PEAC2ATAM0150 PEAE2ATAM0150 PEAN2ATAM0150 PEAH2ATAM0150 PEAL2ATAM0150

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEAB2ATEJ0150 PEAC2ATEJ0150 PEAE2ATEJ0150 PEAN2ATEJ0150 PEAH2ATEJ0150 PEAL2ATEJ0150
LT, ST, I, and GF PEAB2ATEK0150 PEAC2ATEK0150 PEAE2ATEK0150 PEAN2ATEK0150 PEAH2ATEK0150 PEAL2ATEK0150
LT, ST, I, and GF alarm PEAB2ATEL0150 PEAC2ATEL0150 PEAE2ATEL0150 PEAN2ATEL0150 PEAH2ATEL0150 PEAL2ATEL0150
LT, ST, I, and GF (defeatable) PEAB2ATEM0150 PEAC2ATEM0150 PEAE2ATEM0150 PEAN2ATEM0150 PEAH2ATEM0150 PEAL2ATEM0150

Intro Global with UL PE150 - 100% UL rated - 2 poles - 150A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

A 18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEBB2ATSB0150 PEBC2ATSB0150 PEBE2ATSB0150 PEBN2ATSB0150 PEBH2ATSB0150 PEBL2ATSB0150
B LT, ST, I, and GF
ST and I
PEBB2ATSE0150
PEBB2ATSF0150
PEBC2ATSE0150
PEBC2ATSF0150
PEBE2ATSE0150
PEBE2ATSF0150
PEBN2ATSE0150
PEBN2ATSF0150
PEBH2ATSE0150
PEBH2ATSF0150
PEBL2ATSE0150
PEBL2ATSF0150
ST, I, and GF PEBB2ATSH0150 PEBC2ATSH0150 PEBE2ATSH0150 PEBN2ATSH0150 PEBH2ATSH0150 PEBL2ATSH0150

C PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEBB2ATAJ0150 PEBC2ATAJ0150 PEBE2ATAJ0150 PEBN2ATAJ0150 PEBH2ATAJ0150 PEBL2ATAJ0150
LT, ST, I, and GF PEBB2ATAK0150 PEBC2ATAK0150 PEBE2ATAK0150 PEBN2ATAK0150 PEBH2ATAK0150 PEBL2ATAK0150
LT, ST, I, and GF alarm PEBB2ATAL0150 PEBC2ATAL0150 PEBE2ATAL0150 PEBN2ATAL0150 PEBH2ATAL0150 PEBL2ATAL0150
LT, ST, I, and GF (defeatable) PEBB2ATAM0150 PEBC2ATAM0150 PEBE2ATAM0150 PEBN2ATAM0150 PEBH2ATAM0150 PEBL2ATAM0150
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEBB2ATEJ0150 PEBC2ATEJ0150 PEBE2ATEJ0150 PEBN2ATEJ0150 PEBH2ATEJ0150 PEBL2ATEJ0150
LT, ST, I, and GF PEBB2ATEK0150 PEBC2ATEK0150 PEBE2ATEK0150 PEBN2ATEK0150 PEBH2ATEK0150 PEBL2ATEK0150
E LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEBB2ATEL0150
PEBB2ATEM0150
PEBC2ATEL0150
PEBC2ATEM0150
PEBE2ATEL0150
PEBE2ATEM0150
PEBN2ATEL0150
PEBN2ATEM0150
PEBH2ATEL0150
PEBH2ATEM0150
PEBL2ATEL0150
PEBL2ATEM0150

Global with UL PE150 - 3 poles - 150A


F In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
G PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEAB3ATSB0150 PEAC3ATSB0150 PEAE3ATSB0150 PEAN3ATSB0150 PEAH3ATSB0150 PEAL3ATSB0150
LT, ST, I, and GF PEAB3ATSE0150 PEAC3ATSE0150 PEAE3ATSE0150 PEAN3ATSE0150 PEAH3ATSE0150 PEAL3ATSE0150

X ST and I
ST, I, and GF
PEAB3ATSF0150
PEAB3ATSH0150
PEAC3ATSF0150
PEAC3ATSH0150
PEAE3ATSF0150
PEAE3ATSH0150
PEAN3ATSF0150
PEAN3ATSH0150
PEAH3ATSF0150
PEAH3ATSH0150
PEAL3ATSF0150
PEAL3ATSH0150

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB3ATAJ0150 PEAC3ATAJ0150 PEAE3ATAJ0150 PEAN3ATAJ0150 PEAH3ATAJ0150 PEAL3ATAJ0150
LT, ST, I, and GF PEAB3ATAK0150 PEAC3ATAK0150 PEAE3ATAK0150 PEAN3ATAK0150 PEAH3ATAK0150 PEAL3ATAK0150
LT, ST, I, and GF alarm PEAB3ATAL0150 PEAC3ATAL0150 PEAE3ATAL0150 PEAN3ATAL0150 PEAH3ATAL0150 PEAL3ATAL0150
LT, ST, I, and GF (defeatable) PEAB3ATAM0150 PEAC3ATAM0150 PEAE3ATAM0150 PEAN3ATAM0150 PEAH3ATAM0150 PEAL3ATAM0150

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEAB3ATEJ0150 PEAC3ATEJ0150 PEAE3ATEJ0150 PEAN3ATEJ0150 PEAH3ATEJ0150 PEAL3ATEJ0150
LT, ST, I, and GF PEAB3ATEK0150 PEAC3ATEK0150 PEAE3ATEK0150 PEAN3ATEK0150 PEAH3ATEK0150 PEAL3ATEK0150
LT, ST, I, and GF alarm PEAB3ATEL0150 PEAC3ATEL0150 PEAE3ATEL0150 PEAN3ATEL0150 PEAH3ATEL0150 PEAL3ATEL0150
LT, ST, I, and GF (defeatable) PEAB3ATEM0150 PEAC3ATEM0150 PEAE3ATEM0150 PEAN3ATEM0150 PEAH3ATEM0150 PEAL3ATEM0150

A.20
GuardEon
150A complete circuit breaker - GuardEon PE150

Global with UL PE150 - 100% UL rated - 3 poles - 150A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEBB3ATSB0150 PEBC3ATSB0150 PEBE3ATSB0150 PEBN3ATSB0150 PEBH3ATSB0150 PEBL3ATSB0150
LT, ST, I, and GF PEBB3ATSE0150 PEBC3ATSE0150 PEBE3ATSE0150 PEBN3ATSE0150 PEBH3ATSE0150 PEBL3ATSE0150
ST and I PEBB3ATSF0150 PEBC3ATSF0150 PEBE3ATSF0150 PEBN3ATSF0150 PEBH3ATSF0150 PEBL3ATSF0150
ST, I, and GF PEBB3ATSH0150 PEBC3ATSH0150 PEBE3ATSH0150 PEBN3ATSH0150 PEBH3ATSH0150 PEBL3ATSH0150

PremEon G Current electronic trip units - Fully adjustable settings

Order codes
LT, ST, and I PEBB3ATAJ0150 PEBC3ATAJ0150 PEBE3ATAJ0150 PEBN3ATAJ0150 PEBH3ATAJ0150 PEBL3ATAJ0150
LT, ST, I, and GF PEBB3ATAK0150 PEBC3ATAK0150 PEBE3ATAK0150 PEBN3ATAK0150 PEBH3ATAK0150 PEBL3ATAK0150
LT, ST, I, and GF alarm PEBB3ATAL0150 PEBC3ATAL0150 PEBE3ATAL0150 PEBN3ATAL0150 PEBH3ATAL0150 PEBL3ATAL0150
LT, ST, I, and GF (defeatable) PEBB3ATAM0150 PEBC3ATAM0150 PEBE3ATAM0150 PEBN3ATAM0150 PEBH3ATAM0150 PEBL3ATAM0150

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEBB3ATEJ0150 PEBC3ATEJ0150 PEBE3ATEJ0150 PEBN3ATEJ0150 PEBH3ATEJ0150 PEBL3ATEJ0150
LT, ST, I, and GF PEBB3ATEK0150 PEBC3ATEK0150 PEBE3ATEK0150 PEBN3ATEK0150 PEBH3ATEK0150 PEBL3ATEK0150
LT, ST, I, and GF alarm PEBB3ATEL0150 PEBC3ATEL0150 PEBE3ATEL0150 PEBN3ATEL0150 PEBH3ATEL0150 PEBL3ATEL0150
LT, ST, I, and GF (defeatable) PEBB3ATEM0150 PEBC3ATEM0150 PEBE3ATEM0150 PEBN3ATEM0150 PEBH3ATEM0150 PEBL3ATEM0150

Global with UL PE150 - 4 poles - 150A(1) Intro


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
A
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEAB4ATSB0150 PEAC4ATSB0150 PEAE4ATSB0150 PEAN4ATSB0150 PEAH4ATSB0150 PEAL4ATSB0150
LT, ST, I, and GF
ST and I
PEAB4ATSE0150
PEAB4ATSF0150
PEAC4ATSE0150
PEAC4ATSF0150
PEAE4ATSE0150
PEAE4ATSF0150
PEAN4ATSE0150
PEAN4ATSF0150
PEAH4ATSE0150
PEAH4ATSF0150
PEAL4ATSE0150
PEAL4ATSF0150
B
ST, I, and GF PEAB4ATSH0150 PEAC4ATSH0150 PEAE4ATSH0150 PEAN4ATSH0150 PEAH4ATSH0150 PEAL4ATSH0150

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEAB4ATAJ0150 PEAC4ATAJ0150 PEAE4ATAJ0150 PEAN4ATAJ0150 PEAH4ATAJ0150 PEAL4ATAJ0150
C
LT, ST, I, and GF PEAB4ATAK0150 PEAC4ATAK0150 PEAE4ATAK0150 PEAN4ATAK0150 PEAH4ATAK0150 PEAL4ATAK0150
LT, ST, I, and GF alarm PEAB4ATAL0150 PEAC4ATAL0150 PEAE4ATAL0150 PEAN4ATAL0150 PEAH4ATAL0150 PEAL4ATAL0150
LT, ST, I, and GF (defeatable) PEAB4ATAM0150 PEAC4ATAM0150 PEAE4ATAM0150 PEAN4ATAM0150 PEAH4ATAM0150 PEAL4ATAM0150
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEAB4ATEJ0150 PEAC4ATEJ0150 PEAE4ATEJ0150 PEAN4ATEJ0150 PEAH4ATEJ0150 PEAL4ATEJ0150
LT, ST, I, and GF PEAB4ATEK0150 PEAC4ATEK0150 PEAE4ATEK0150 PEAN4ATEK0150 PEAH4ATEK0150 PEAL4ATEK0150
LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEAB4ATEL0150
PEAB4ATEM0150
PEAC4ATEL0150
PEAC4ATEM0150
PEAE4ATEL0150
PEAE4ATEM0150
PEAN4ATEL0150
PEAN4ATEM0150
PEAH4ATEL0150
PEAH4ATEM0150
PEAL4ATEL0150
PEAL4ATEM0150 E

Global with UL PE150 - 100% UL rated - 4 poles - 150A(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.
F
Interrupt Rating @ 480V
18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
G
LT, ST, and I PEBB4ATSB0150 PEBC4ATSB0150 PEBE4ATSB0150 PEBN4ATSB0150 PEBH4ATSB0150 PEBL4ATSB0150
LT, ST, I, and GF PEBB4ATSE0150 PEBC4ATSE0150 PEBE4ATSE0150 PEBN4ATSE0150 PEBH4ATSE0150 PEBL4ATSE0150
ST and I
ST, I, and GF
PEBB4ATSF0150
PEBB4ATSH0150
PEBC4ATSF0150
PEBC4ATSH0150
PEBE4ATSF0150
PEBE4ATSH0150
PEBN4ATSF0150
PEBN4ATSH0150
PEBH4ATSF0150
PEBH4ATSH0150
PEBL4ATSF0150
PEBL4ATSH0150 X
PremEon G Current electronic trip units - Fully adjustable settings
LT, ST, and I PEBB4ATAJ0150 PEBC4ATAJ0150 PEBE4ATAJ0150 PEBN4ATAJ0150 PEBH4ATAJ0150 PEBL4ATAJ0150
LT, ST, I, and GF PEBB4ATAK0150 PEBC4ATAK0150 PEBE4ATAK0150 PEBN4ATAK0150 PEBH4ATAK0150 PEBL4ATAK0150
LT, ST, I, and GF alarm PEBB4ATAL0150 PEBC4ATAL0150 PEBE4ATAL0150 PEBN4ATAL0150 PEBH4ATAL0150 PEBL4ATAL0150
LT, ST, I, and GF (defeatable) PEBB4ATAM0150 PEBC4ATAM0150 PEBE4ATAM0150 PEBN4ATAM0150 PEBH4ATAM0150 PEBL4ATAM0150

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEBB4ATEJ0150 PEBC4ATEJ0150 PEBE4ATEJ0150 PEBN4ATEJ0150 PEBH4ATEJ0150 PEBL4ATEJ0150
LT, ST, I, and GF PEBB4ATEK0150 PEBC4ATEK0150 PEBE4ATEK0150 PEBN4ATEK0150 PEBH4ATEK0150 PEBL4ATEK0150
LT, ST, I, and GF alarm PEBB4ATEL0150 PEBC4ATEL0150 PEBE4ATEL0150 PEBN4ATEL0150 PEBH4ATEL0150 PEBL4ATEL0150
LT, ST, I, and GF (defeatable) PEBB4ATEM0150 PEBC4ATEM0150 PEBE4ATEM0150 PEBN4ATEM0150 PEBH4ATEM0150 PEBL4ATEM0150

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.21
GuardEon
150A complete circuit breaker - GuardEon PE250

Global with UL PE250 - 2 poles - 150A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEDB2ATSB0150 PEDC2ATSB0150 PEDE2ATSB0150 PEDN2ATSB0150 PEDH2ATSB0150 PEDL2ATSB0150
LT, ST, I, and GF PEDB2ATSE0150 PEDC2ATSE0150 PEDE2ATSE0150 PEDN2ATSE0150 PEDH2ATSE0150 PEDL2ATSE0150
ST and I PEDB2ATSF0150 PEDC2ATSF0150 PEDE2ATSF0150 PEDN2ATSF0150 PEDH2ATSF0150 PEDL2ATSF0150
ST, I, and GF PEDB2ATSH0150 PEDC2ATSH0150 PEDE2ATSH0150 PEDN2ATSH0150 PEDH2ATSH0150 PEDL2ATSH0150

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEDB2ATAJ0150 PEDC2ATAJ0150 PEDE2ATAJ0150 PEDN2ATAJ0150 PEDH2ATAJ0150 PEDL2ATAJ0150
LT, ST, I, and GF PEDB2ATAK0150 PEDC2ATAK0150 PEDE2ATAK0150 PEDN2ATAK0150 PEDH2ATAK0150 PEDL2ATAK0150
GuardEon

LT, ST, I, and GF alarm PEDB2ATAL0150 PEDC2ATAL0150 PEDE2ATAL0150 PEDN2ATAL0150 PEDH2ATAL0150 PEDL2ATAL0150
LT, ST, I, and GF (defeatable) PEDB2ATAM0150 PEDC2ATAM0150 PEDE2ATAM0150 PEDN2ATAM0150 PEDH2ATAM0150 PEDL2ATAM0150

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEDB2ATEJ0150 PEDC2ATEJ0150 PEDE2ATEJ0150 PEDN2ATEJ0150 PEDH2ATEJ0150 PEDL2ATEJ0150
LT, ST, I, and GF PEDB2ATEK0150 PEDC2ATEK0150 PEDE2ATEK0150 PEDN2ATEK0150 PEDH2ATEK0150 PEDL2ATEK0150
LT, ST, I, and GF alarm PEDB2ATEL0150 PEDC2ATEL0150 PEDE2ATEL0150 PEDN2ATEL0150 PEDH2ATEL0150 PEDL2ATEL0150
LT, ST, I, and GF (defeatable) PEDB2ATEM0150 PEDC2ATEM0150 PEDE2ATEM0150 PEDN2ATEM0150 PEDH2ATEM0150 PEDL2ATEM0150

Intro Global with UL PE250 - 100% UL rated - 2 poles - 150A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


A 18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEEB2ATSB0150 PEEC2ATSB0150 PEEE2ATSB0150 PEEN2ATSB0150 PEEH2ATSB0150 PEEL2ATSB0150
B LT, ST, I, and GF
ST and I
PEEB2ATSE0150
PEEB2ATSF0150
PEEC2ATSE0150
PEEC2ATSF0150
PEEE2ATSE0150
PEEE2ATSF0150
PEEN2ATSE0150
PEEN2ATSF0150
PEEH2ATSE0150
PEEH2ATSF0150
PEEL2ATSE0150
PEEL2ATSF0150
ST, I, and GF PEEB2ATSH0150 PEEC2ATSH0150 PEEE2ATSH0150 PEEN2ATSH0150 PEEH2ATSH0150 PEEL2ATSH0150

PremEon G Current electronic trip units - Fully adjustable settings


C LT, ST, and I PEEB2ATAJ0150 PEEC2ATAJ0150 PEEE2ATAJ0150 PEEN2ATAJ0150 PEEH2ATAJ0150 PEEL2ATAJ0150
LT, ST, I, and GF PEEB2ATAK0150 PEEC2ATAK0150 PEEE2ATAK0150 PEEN2ATAK0150 PEEH2ATAK0150 PEEL2ATAK0150
LT, ST, I, and GF alarm PEEB2ATAL0150 PEEC2ATAL0150 PEEE2ATAL0150 PEEN2ATAL0150 PEEH2ATAL0150 PEEL2ATAL0150
LT, ST, I, and GF (defeatable) PEEB2ATAM0150 PEEC2ATAM0150 PEEE2ATAM0150 PEEN2ATAM0150 PEEH2ATAM0150 PEEL2ATAM0150
D PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEEB2ATEJ0150 PEEC2ATEJ0150 PEEE2ATEJ0150 PEEN2ATEJ0150 PEEH2ATEJ0150 PEEL2ATEJ0150
LT, ST, I, and GF PEEB2ATEK0150 PEEC2ATEK0150 PEEE2ATEK0150 PEEN2ATEK0150 PEEH2ATEK0150 PEEL2ATEK0150

E LT, ST, I, and GF alarm


LT, ST, I, and GF (defeatable)
PEEB2ATEL0150
PEEB2ATEM0150
PEEC2ATEL0150
PEEC2ATEM0150
PEEE2ATEL0150
PEEE2ATEM0150
PEEN2ATEL0150
PEEN2ATEM0150
PEEH2ATEL0150
PEEH2ATEM0150
PEEL2ATEL0150
PEEL2ATEM0150

Global with UL PE250 - 3 poles - 150A


F In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
G PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEDB3ATSB0150 PEDC3ATSB0150 PEDE3ATSB0150 PEDN3ATSB0150 PEDH3ATSB0150 PEDL3ATSB0150
LT, ST, I, and GF PEDB3ATSE0150 PEDC3ATSE0150 PEDE3ATSE0150 PEDN3ATSE0150 PEDH3ATSE0150 PEDL3ATSE0150
ST and I PEDB3ATSF0150 PEDC3ATSF0150 PEDE3ATSF0150 PEDN3ATSF0150 PEDH3ATSF0150 PEDL3ATSF0150
X ST, I, and GF PEDB3ATSH0150 PEDC3ATSH0150 PEDE3ATSH0150 PEDN3ATSH0150 PEDH3ATSH0150 PEDL3ATSH0150

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEDB3ATAJ0150 PEDC3ATAJ0150 PEDE3ATAJ0150 PEDN3ATAJ0150 PEDH3ATAJ0150 PEDL3ATAJ0150
LT, ST, I, and GF PEDB3ATAK0150 PEDC3ATAK0150 PEDE3ATAK0150 PEDN3ATAK0150 PEDH3ATAK0150 PEDL3ATAK0150
LT, ST, I, and GF alarm PEDB3ATAL0150 PEDC3ATAL0150 PEDE3ATAL0150 PEDN3ATAL0150 PEDH3ATAL0150 PEDL3ATAL0150
LT, ST, I, and GF (defeatable) PEDB3ATAM0150 PEDC3ATAM0150 PEDE3ATAM0150 PEDN3ATAM0150 PEDH3ATAM0150 PEDL3ATAM0150

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEDB3ATEJ0150 PEDC3ATEJ0150 PEDE3ATEJ0150 PEDN3ATEJ0150 PEDH3ATEJ0150 PEDL3ATEJ0150
LT, ST, I, and GF PEDB3ATEK0150 PEDC3ATEK0150 PEDE3ATEK0150 PEDN3ATEK0150 PEDH3ATEK0150 PEDL3ATEK0150
LT, ST, I, and GF alarm PEDB3ATEL0150 PEDC3ATEL0150 PEDE3ATEL0150 PEDN3ATEL0150 PEDH3ATEL0150 PEDL3ATEL0150
LT, ST, I, and GF (defeatable) PEDB3ATEM0150 PEDC3ATEM0150 PEDE3ATEM0150 PEDN3ATEM0150 PEDH3ATEM0150 PEDL3ATEM0150

A.22
GuardEon
150A complete circuit breaker - GuardEon PE250

Global with UL PE250 - 100% UL rated - 3 poles - 150A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEEB3ATSB0150 PEEC3ATSB0150 PEEE3ATSB0150 PEEN3ATSB0150 PEEH3ATSB0150 PEEL3ATSB0150
LT, ST, I, and GF PEEB3ATSE0150 PEEC3ATSE0150 PEEE3ATSE0150 PEEN3ATSE0150 PEEH3ATSE0150 PEEL3ATSE0150
ST and I PEEB3ATSF0150 PEEC3ATSF0150 PEEE3ATSF0150 PEEN3ATSF0150 PEEH3ATSF0150 PEEL3ATSF0150
ST, I, and GF PEEB3ATSH0150 PEEC3ATSH0150 PEEE3ATSH0150 PEEN3ATSH0150 PEEH3ATSH0150 PEEL3ATSH0150

PremEon G Current electronic trip units - Fully adjustable settings

Order codes
LT, ST, and I PEEB3ATAJ0150 PEEC3ATAJ0150 PEEE3ATAJ0150 PEEN3ATAJ0150 PEEH3ATAJ0150 PEEL3ATAJ0150
LT, ST, I, and GF PEEB3ATAK0150 PEEC3ATAK0150 PEEE3ATAK0150 PEEN3ATAK0150 PEEH3ATAK0150 PEEL3ATAK0150
LT, ST, I, and GF alarm PEEB3ATAL0150 PEEC3ATAL0150 PEEE3ATAL0150 PEEN3ATAL0150 PEEH3ATAL0150 PEEL3ATAL0150
LT, ST, I, and GF (defeatable) PEEB3ATAM0150 PEEC3ATAM0150 PEEE3ATAM0150 PEEN3ATAM0150 PEEH3ATAM0150 PEEL3ATAM0150

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEEB3ATEJ0150 PEEC3ATEJ0150 PEEE3ATEJ0150 PEEN3ATEJ0150 PEEH3ATEJ0150 PEEL3ATEJ0150
LT, ST, I, and GF PEEB3ATEK0150 PEEC3ATEK0150 PEEE3ATEK0150 PEEN3ATEK0150 PEEH3ATEK0150 PEEL3ATEK0150
LT, ST, I, and GF alarm PEEB3ATEL0150 PEEC3ATEL0150 PEEE3ATEL0150 PEEN3ATEL0150 PEEH3ATEL0150 PEEL3ATEL0150
LT, ST, I, and GF (defeatable) PEEB3ATEM0150 PEEC3ATEM0150 PEEE3ATEM0150 PEEN3ATEM0150 PEEH3ATEM0150 PEEL3ATEM0150

Global with UL PE250 - 4 poles - 150A(1) Intro


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA A
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEDB4ATSB0150 PEDC4ATSB0150 PEDE4ATSB0150 PEDN4ATSB0150 PEDH4ATSB0150 PEDL4ATSB0150
LT, ST, I, and GF
ST and I
PEDB4ATSE0150
PEDB4ATSF0150
PEDC4ATSE0150
PEDC4ATSF0150
PEDE4ATSE0150
PEDE4ATSF0150
PEDN4ATSE0150
PEDN4ATSF0150
PEDH4ATSE0150
PEDH4ATSF0150
PEDL4ATSE0150
PEDL4ATSF0150
B
ST, I, and GF PEDB4ATSH0150 PEDC4ATSH0150 PEDE4ATSH0150 PEDN4ATSH0150 PEDH4ATSH0150 PEDL4ATSH0150

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEDB4ATAJ0150 PEDC4ATAJ0150 PEDE4ATAJ0150 PEDN4ATAJ0150 PEDH4ATAJ0150 PEDL4ATAJ0150
C
LT, ST, I, and GF PEDB4ATAK0150 PEDC4ATAK0150 PEDE4ATAK0150 PEDN4ATAK0150 PEDH4ATAK0150 PEDL4ATAK0150
LT, ST, I, and GF alarm PEDB4ATAL0150 PEDC4ATAL0150 PEDE4ATAL0150 PEDN4ATAL0150 PEDH4ATAL0150 PEDL4ATAL0150
LT, ST, I, and GF (defeatable) PEDB4ATAM0150 PEDC4ATAM0150 PEDE4ATAM0150 PEDN4ATAM0150 PEDH4ATAM0150 PEDL4ATAM0150

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


D
LT, ST, and I PEDB4ATEJ0150 PEDC4ATEJ0150 PEDE4ATEJ0150 PEDN4ATEJ0150 PEDH4ATEJ0150 PEDL4ATEJ0150
LT, ST, I, and GF PEDB4ATEK0150 PEDC4ATEK0150 PEDE4ATEK0150 PEDN4ATEK0150 PEDH4ATEK0150 PEDL4ATEK0150
LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEDB4ATEL0150
PEDB4ATEM0150
PEDC4ATEL0150
PEDC4ATEM0150
PEDE4ATEL0150
PEDE4ATEM0150
PEDN4ATEL0150
PEDN4ATEM0150
PEDH4ATEL0150
PEDH4ATEM0150
PEDL4ATEL0150
PEDL4ATEM0150 E

Global with UL PE250 - 100% UL rated - 4 poles - 150A(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.
F
Interrupt Rating @ 480V
18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
G
LT, ST, and I PEEB4ATSB0150 PEEC4ATSB0150 PEEE4ATSB0150 PEEN4ATSB0150 PEEH4ATSB0150 PEEL4ATSB0150
LT, ST, I, and GF PEEB4ATSE0150 PEEC4ATSE0150 PEEE4ATSE0150 PEEN4ATSE0150 PEEH4ATSE0150 PEEL4ATSE0150
ST and I
ST, I, and GF
PEEB4ATSF0150
PEEB4ATSH0150
PEEC4ATSF0150
PEEC4ATSH0150
PEEE4ATSF0150
PEEE4ATSH0150
PEEN4ATSF0150
PEEN4ATSH0150
PEEH4ATSF0150
PEEH4ATSH0150
PEEL4ATSF0150
PEEL4ATSH0150 X
PremEon G Current electronic trip units - Fully adjustable settings
LT, ST, and I PEEB4ATAJ0150 PEEC4ATAJ0150 PEEE4ATAJ0150 PEEN4ATAJ0150 PEEH4ATAJ0150 PEEL4ATAJ0150
LT, ST, I, and GF PEEB4ATAK0150 PEEC4ATAK0150 PEEE4ATAK0150 PEEN4ATAK0150 PEEH4ATAK0150 PEEL4ATAK0150
LT, ST, I, and GF alarm PEEB4ATAL0150 PEEC4ATAL0150 PEEE4ATAL0150 PEEN4ATAL0150 PEEH4ATAL0150 PEEL4ATAL0150
LT, ST, I, and GF (defeatable) PEEB4ATAM0150 PEEC4ATAM0150 PEEE4ATAM0150 PEEN4ATAM0150 PEEH4ATAM0150 PEEL4ATAM0150

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEEB4ATEJ0150 PEEC4ATEJ0150 PEEE4ATEJ0150 PEEN4ATEJ0150 PEEH4ATEJ0150 PEEL4ATEJ0150
LT, ST, I, and GF PEEB4ATEK0150 PEEC4ATEK0150 PEEE4ATEK0150 PEEN4ATEK0150 PEEH4ATEK0150 PEEL4ATEK0150
LT, ST, I, and GF alarm PEEB4ATEL0150 PEEC4ATEL0150 PEEE4ATEL0150 PEEN4ATEL0150 PEEH4ATEL0150 PEEL4ATEL0150
LT, ST, I, and GF (defeatable) PEEB4ATEM0150 PEEC4ATEM0150 PEEE4ATEM0150 PEEN4ATEM0150 PEEH4ATEM0150 PEEL4ATEM0150

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.23
GuardEon
250A complete circuit breaker - GuardEon PE250

Global with UL PE250 - 2 poles - 250A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEDB2ATSB0250 PEDC2ATSB0250 PEDE2ATSB0250 PEDN2ATSB0250 PEDH2ATSB0250 PEDL2ATSB0250
LT, ST, I, and GF PEDB2ATSE0250 PEDC2ATSE0250 PEDE2ATSE0250 PEDN2ATSE0250 PEDH2ATSE0250 PEDL2ATSE0250
ST and I PEDB2ATSF0250 PEDC2ATSF0250 PEDE2ATSF0250 PEDN2ATSF0250 PEDH2ATSF0250 PEDL2ATSF0250
ST, I, and GF PEDB2ATSH0250 PEDC2ATSH0250 PEDE2ATSH0250 PEDN2ATSH0250 PEDH2ATSH0250 PEDL2ATSH0250

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEDB2ATAJ0250 PEDC2ATAJ0250 PEDE2ATAJ0250 PEDN2ATAJ0250 PEDH2ATAJ0250 PEDL2ATAJ0250
LT, ST, I, and GF PEDB2ATAK0250 PEDC2ATAK0250 PEDE2ATAK0250 PEDN2ATAK0250 PEDH2ATAK0250 PEDL2ATAK0250
GuardEon

LT, ST, I, and GF alarm PEDB2ATAL0250 PEDC2ATAL0250 PEDE2ATAL0250 PEDN2ATAL0250 PEDH2ATAL0250 PEDL2ATAL0250
LT, ST, I, and GF (defeatable) PEDB2ATAM0250 PEDC2ATAM0250 PEDE2ATAM0250 PEDN2ATAM0250 PEDH2ATAM0250 PEDL2ATAM0250

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEDB2ATEJ0250 PEDC2ATEJ0250 PEDE2ATEJ0250 PEDN2ATEJ0250 PEDH2ATEJ0250 PEDL2ATEJ0250
LT, ST, I, and GF PEDB2ATEK0250 PEDC2ATEK0250 PEDE2ATEK0250 PEDN2ATEK0250 PEDH2ATEK0250 PEDL2ATEK0250
LT, ST, I, and GF alarm PEDB2ATEL0250 PEDC2ATEL0250 PEDE2ATEL0250 PEDN2ATEL0250 PEDH2ATEL0250 PEDL2ATEL0250
LT, ST, I, and GF (defeatable) PEDB2ATEM0250 PEDC2ATEM0250 PEDE2ATEM0250 PEDN2ATEM0250 PEDH2ATEM0250 PEDL2ATEM0250

Intro Global with UL PE250 - 100% UL rated - 2 poles - 250A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

A 18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEEB2ATSB0250 PEEC2ATSB0250 PEEE2ATSB0250 PEEN2ATSB0250 PEEH2ATSB0250 PEEL2ATSB0250
B LT, ST, I, and GF
ST and I
PEEB2ATSE0250
PEEB2ATSF0250
PEEC2ATSE0250
PEEC2ATSF0250
PEEE2ATSE0250
PEEE2ATSF0250
PEEN2ATSE0250
PEEN2ATSF0250
PEEH2ATSE0250
PEEH2ATSF0250
PEEL2ATSE0250
PEEL2ATSF0250
ST, I, and GF PEEB2ATSH0250 PEEC2ATSH0250 PEEE2ATSH0250 PEEN2ATSH0250 PEEH2ATSH0250 PEEL2ATSH0250

C PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEEB2ATAJ0250 PEEC2ATAJ0250 PEEE2ATAJ0250 PEEN2ATAJ0250 PEEH2ATAJ0250 PEEL2ATAJ0250
LT, ST, I, and GF PEEB2ATAK0250 PEEC2ATAK0250 PEEE2ATAK0250 PEEN2ATAK0250 PEEH2ATAK0250 PEEL2ATAK0250
LT, ST, I, and GF alarm PEEB2ATAL0250 PEEC2ATAL0250 PEEE2ATAL0250 PEEN2ATAL0250 PEEH2ATAL0250 PEEL2ATAL0250
LT, ST, I, and GF (defeatable) PEEB2ATAM0250 PEEC2ATAM0250 PEEE2ATAM0250 PEEN2ATAM0250 PEEH2ATAM0250 PEEL2ATAM0250
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEBB2ATEJ0150 PEBC2ATEJ0150 PEBE2ATEJ0150 PEBN2ATEJ0150 PEBH2ATEJ0150 PEBL2ATEJ0150
LT, ST, I, and GF PEBB2ATEK0150 PEBC2ATEK0150 PEBE2ATEK0150 PEBN2ATEK0150 PEBH2ATEK0150 PEBL2ATEK0150
E LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEBB2ATEL0150
PEBB2ATEM0150
PEBC2ATEL0150
PEBC2ATEM0150
PEBE2ATEL0150
PEBE2ATEM0150
PEBN2ATEL0150
PEBN2ATEM0150
PEBH2ATEL0150
PEBH2ATEM0150
PEBL2ATEL0150
PEBL2ATEM0150

Global with UL PE250 - 3 poles - 250A


F In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
G PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEDB3ATSB0250 PEDC3ATSB0250 PEDE3ATSB0250 PEDN3ATSB0250 PEDH3ATSB0250 PEDL3ATSB0250
LT, ST, I, and GF PEDB3ATSE0250 PEDC3ATSE0250 PEDE3ATSE0250 PEDN3ATSE0250 PEDH3ATSE0250 PEDL3ATSE0250

X ST and I
ST, I, and GF
PEDB3ATSF0250
PEDB3ATSH0250
PEDC3ATSF0250
PEDC3ATSH0250
PEDE3ATSF0250
PEDE3ATSH0250
PEDN3ATSF0250
PEDN3ATSH0250
PEDH3ATSF0250
PEDH3ATSH0250
PEDL3ATSF0250
PEDL3ATSH0250

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEDB3ATAJ0250 PEDC3ATAJ0250 PEDE3ATAJ0250 PEDN3ATAJ0250 PEDH3ATAJ0250 PEDL3ATAJ0250
LT, ST, I, and GF PEDB3ATAK0250 PEDC3ATAK0250 PEDE3ATAK0250 PEDN3ATAK0250 PEDH3ATAK0250 PEDL3ATAK0250
LT, ST, I, and GF alarm PEDB3ATAL0250 PEDC3ATAL0250 PEDE3ATAL0250 PEDN3ATAL0250 PEDH3ATAL0250 PEDL3ATAL0250
LT, ST, I, and GF (defeatable) PEDB3ATAM0250 PEDC3ATAM0250 PEDE3ATAM0250 PEDN3ATAM0250 PEDH3ATAM0250 PEDL3ATAM0250

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEDB3ATEJ0250 PEDC3ATEJ0250 PEDE3ATEJ0250 PEDN3ATEJ0250 PEDH3ATEJ0250 PEDL3ATEJ0250
LT, ST, I, and GF PEDB3ATEK0250 PEDC3ATEK0250 PEDE3ATEK0250 PEDN3ATEK0250 PEDH3ATEK0250 PEDL3ATEK0250
LT, ST, I, and GF alarm PEDB3ATEL0250 PEDC3ATEL0250 PEDE3ATEL0250 PEDN3ATEL0250 PEDH3ATEL0250 PEDL3ATEL0250
LT, ST, I, and GF (defeatable) PEDB3ATEM0250 PEDC3ATEM0250 PEDE3ATEM0250 PEDN3ATEM0250 PEDH3ATEM0250 PEDL3ATEM0250

A.24
GuardEon
250A complete circuit breaker - GuardEon PE250

Global with UL PE250 - 100% UL rated - 3 poles - 250A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEEB3ATSB0250 PEEC3ATSB0250 PEEE3ATSB0250 PEEN3ATSB0250 PEEH3ATSB0250 PEEL3ATSB0250
LT, ST, I, and GF PEEB3ATSE0250 PEEC3ATSE0250 PEEE3ATSE0250 PEEN3ATSE0250 PEEH3ATSE0250 PEEL3ATSE0250
ST and I PEEB3ATSF0250 PEEC3ATSF0250 PEEE3ATSF0250 PEEN3ATSF0250 PEEH3ATSF0250 PEEL3ATSF0250
ST, I, and GF PEEB3ATSH0250 PEEC3ATSH0250 PEEE3ATSH0250 PEEN3ATSH0250 PEEH3ATSH0250 PEEL3ATSH0250

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEEB3ATAJ0250 PEEC3ATAJ0250 PEEE3ATAJ0250 PEEN3ATAJ0250 PEEH3ATAJ0250 PEEL3ATAJ0250

Order codes
LT, ST, I, and GF PEEB3ATAK0250 PEEC3ATAK0250 PEEE3ATAK0250 PEEN3ATAK0250 PEEH3ATAK0250 PEEL3ATAK0250
LT, ST, I, and GF alarm PEEB3ATAL0250 PEEC3ATAL0250 PEEE3ATAL0250 PEEN3ATAL0250 PEEH3ATAL0250 PEEL3ATAL0250
LT, ST, I, and GF (defeatable) PEEB3ATAM0250 PEEC3ATAM0250 PEEE3ATAM0250 PEEN3ATAM0250 PEEH3ATAM0250 PEEL3ATAM0250

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEEB3ATEJ0250 PEEC3ATEJ0250 PEEE3ATEJ0250 PEEN3ATEJ0250 PEEH3ATEJ0250 PEEL3ATEJ0250
LT, ST, I, and GF PEEB3ATEK0250 PEEC3ATEK0250 PEEE3ATEK0250 PEEN3ATEK0250 PEEH3ATEK0250 PEEL3ATEK0250
LT, ST, I, and GF alarm PEEB3ATEL0250 PEEC3ATEL0250 PEEE3ATEL0250 PEEN3ATEL0250 PEEH3ATEL0250 PEEL3ATEL0250
LT, ST, I, and GF (defeatable) PEEB3ATEM0250 PEEC3ATEM0250 PEEE3ATEM0250 PEEN3ATEM0250 PEEH3ATEM0250 PEEL3ATEM0250

Global with UL PE250 - 4 poles - 250A(1) Intro


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

18kA 25kA
Interrupt Rating @ 480V
35kA 65kA 100kA 150kA
A
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PEDB4ATSB0250 PEDC4ATSB0250 PEDE4ATSB0250 PEDN4ATSB0250 PEDH4ATSB0250 PEDL4ATSB0250
LT, ST, I, and GF
ST and I
PEDB4ATSE0250
PEDB4ATSF0250
PEDC4ATSE0250
PEDC4ATSF0250
PEDE4ATSE0250
PEDE4ATSF0250
PEDN4ATSE0250
PEDN4ATSF0250
PEDH4ATSE0250
PEDH4ATSF0250
PEDL4ATSE0250
PEDL4ATSF0250
B
ST, I, and GF PEDB4ATSH0250 PEDC4ATSH0250 PEDE4ATSH0250 PEDN4ATSH0250 PEDH4ATSH0250 PEDL4ATSH0250

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PEDB4ATAJ0250 PEDC4ATAJ0250 PEDE4ATAJ0250 PEDN4ATAJ0250 PEDH4ATAJ0250 PEDL4ATAJ0250
C
LT, ST, I, and GF PEDB4ATAK0250 PEDC4ATAK0250 PEDE4ATAK0250 PEDN4ATAK0250 PEDH4ATAK0250 PEDL4ATAK0250
LT, ST, I, and GF alarm PEDB4ATAL0250 PEDC4ATAL0250 PEDE4ATAL0250 PEDN4ATAL0250 PEDH4ATAL0250 PEDL4ATAL0250
LT, ST, I, and GF (defeatable) PEDB4ATAM0250 PEDC4ATAM0250 PEDE4ATAM0250 PEDN4ATAM0250 PEDH4ATAM0250 PEDL4ATAM0250
D
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PEDB4ATEJ0250 PEDC4ATEJ0250 PEDE4ATEJ0250 PEDN4ATEJ0250 PEDH4ATEJ0250 PEDL4ATEJ0250
LT, ST, I, and GF PEDB4ATEK0250 PEDC4ATEK0250 PEDE4ATEK0250 PEDN4ATEK0250 PEDH4ATEK0250 PEDL4ATEK0250
LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PEDB4ATEL0250
PEDB4ATEM0250
PEDC4ATEL0250
PEDC4ATEM0250
PEDE4ATEL0250
PEDE4ATEM0250
PEDN4ATEL0250
PEDN4ATEM0250
PEDH4ATEL0250
PEDH4ATEM0250
PEDL4ATEL0250
PEDL4ATEM0250 E

Global with UL PE250 - 100% UL rated - 4 poles - 250A(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.
F
Interrupt Rating @ 480V
18kA 25kA 35kA 65kA 100kA 150kA
PremEon S electronic trip units - Tracking Short-Time settings
 
G
LT, ST, and I PEEB4ATSB0250 PEEC4ATSB0250 PEEE4ATSB0250 PEEN4ATSB0250 PEEH4ATSB0250 PEEL4ATSB0250
LT, ST, I, and GF PEEB4ATSE0250 PEEC4ATSE0250 PEEE4ATSE0250 PEEN4ATSE0250 PEEH4ATSE0250 PEEL4ATSE0250
ST and I
ST, I, and GF
PEEB4ATSF0250
PEEB4ATSH0250
PEEC4ATSF0250
PEEC4ATSH0250
PEEE4ATSF0250
PEEE4ATSH0250
PEEN4ATSF0250
PEEN4ATSH0250
PEEH4ATSF0250
PEEH4ATSH0250
PEEL4ATSF0250
PEEL4ATSH0250 X
PremEon G Current electronic trip units - Fully adjustable settings
LT, ST, and I PEEB4ATAJ0250 PEEC4ATAJ0250 PEEE4ATAJ0250 PEEN4ATAJ0250 PEEH4ATAJ0250 PEEL4ATAJ0250
LT, ST, I, and GF PEEB4ATAK0250 PEEC4ATAK0250 PEEE4ATAK0250 PEEN4ATAK0250 PEEH4ATAK0250 PEEL4ATAK0250
LT, ST, I, and GF alarm PEEB4ATAL0250 PEEC4ATAL0250 PEEE4ATAL0250 PEEN4ATAL0250 PEEH4ATAL0250 PEEL4ATAL0250
LT, ST, I, and GF (defeatable) PEEB4ATAM0250 PEEC4ATAM0250 PEEE4ATAM0250 PEEN4ATAM0250 PEEH4ATAM0250 PEEL4ATAM0250

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PEEB4ATEJ0250 PEEC4ATEJ0250 PEEE4ATEJ0250 PEEN4ATEJ0250 PEEH4ATEJ0250 PEEL4ATEJ0250
LT, ST, I, and GF PEEB4ATEK0250 PEEC4ATEK0250 PEEE4ATEK0250 PEEN4ATEK0250 PEEH4ATEK0250 PEEL4ATEK0250
LT, ST, I, and GF alarm PEEB4ATEL0250 PEEC4ATEL0250 PEEE4ATEL0250 PEEN4ATEL0250 PEEH4ATEL0250 PEEL4ATEL0250
LT, ST, I, and GF (defeatable) PEEB4ATEM0250 PEEC4ATEM0250 PEEE4ATEM0250 PEEN4ATEM0250 PEEH4ATEM0250 PEEL4ATEM0250

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.25
GuardEon
GuardEon

Intro

A.26
Smart, Reliable and Secure
GuardEon
250A complete circuit breaker - GuardEon PG600

Global with UL PG600 - Standard UL rated - 2 poles - 250A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PGFC2ATSB0250 PGFE2ATSB0250 PGFN2ATSB0250 PGFH2ATSB0250 PGFL2ATSB0250 PGFP2ATSB0250
LT, ST, I, and GF PGFC2ATSE0250 PGFE2ATSE0250 PGFN2ATSE0250 PGFH2ATSE0250 PGFL2ATSE0250 PGFP2ATSE0250
ST and I PGFC2ATSF0250 PGFE2ATSF0250 PGFN2ATSF0250 PGFH2ATSF0250 PGFL2ATSF0250 PGFP2ATSF0250
ST, I, and GF PGFC2ATSH0250 PGFE2ATSH0250 PGFN2ATSH0250 PGFH2ATSH0250 PGFL2ATSH0250 PGFP2ATSH0250

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PGFC2ATAJ0250 PGFE2ATAJ0250 PGFN2ATAJ0250 PGFH2ATAJ0250 PGFL2ATAJ0250 PGFP2ATAJ0250
LT, ST, I, and GF PGFC2ATAK0250 PGFE2ATAK0250 PGFN2ATAK0250 PGFH2ATAK0250 PGFL2ATAK0250 PGFP2ATAK0250
GuardEon

LT, ST, I, and GF alarm PGFC2ATAL0250 PGFE2ATAL0250 PGFN2ATAL0250 PGFH2ATAL0250 PGFL2ATAL0250 PGFP2ATAL0250
LT, ST, I, and GF (defeatable) PGFC2ATAM0250 PGFE2ATAM0250 PGFN2ATAM0250 PGFH2ATAM0250 PGFL2ATAM0250 PGFP2ATAM0250

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PGFC2ATEJ0250 PGFE2ATEJ0250 PGFN2ATEJ0250 PGFH2ATEJ0250 PGFL2ATEJ0250 PGFP2ATEJ0250
LT, ST, I, and GF PGFC2ATEK0250 PGFE2ATEK0250 PGFN2ATEK0250 PGFH2ATEK0250 PGFL2ATEK0250 PGFP2ATEK0250
LT, ST, I, and GF alarm PGFC2ATEL0250 PGFE2ATEL0250 PGFN2ATEL0250 PGFH2ATEL0250 PGFL2ATEL0250 PGFP2ATEL0250
LT, ST, I, and GF (defeatable) PGFC2ATEM0250 PGFE2ATEM0250 PGFN2ATEM0250 PGFH2ATEM0250 PGFL2ATEM0250 PGFP2ATEM0250

Intro PremEon G Current electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC2ATAJ0250 PGGE2ATAJ0250 PGGN2ATAJ0250 PGGH2ATAJ0250 PGGL2ATAJ0250 PGGP2ATAJ0250
LT, ST, I, and GF PGGC2ATAK0250 PGGE2ATAK0250 PGGN2ATAK0250 PGGH2ATAK0250 PGGL2ATAK0250 PGGP2ATAK0250
LT, ST, I, and GF alarm PGGC2ATAL0250 PGGE2ATAL0250 PGGN2ATAL0250 PGGH2ATAL0250 PGGL2ATAL0250 PGGP2ATAL0250
LT, ST, I, and GF (defeatable) PGGC2ATAM0250 PGGE2ATAM0250 PGGN2ATAM0250 PGGH2ATAM0250 PGGL2ATAM0250 PGGP2ATAM0250
A
PremEon G Advanced Metering electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC2ATEJ0250 PGGE2ATEJ0250 PGGN2ATEJ0250 PGGH2ATEJ0250 PGGL2ATEJ0250 PGGP2ATEJ0250
LT, ST, I, and GF PGGC2ATEK0250 PGGE2ATEK0250 PGGN2ATEK0250 PGGH2ATEK0250 PGGL2ATEK0250 PGGP2ATEK0250
B LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PGGC2ATEL0250
PGGC2ATEM0250
PGGE2ATEL0250
PGGE2ATEM0250
PGGN2ATEL0250
PGGN2ATEM0250
PGGH2ATEL0250
PGGH2ATEM0250
PGGL2ATEL0250
PGGL2ATEM0250
PGGP2ATEL0250
PGGP2ATEM0250

D
Global with UL PG600 - 100% UL rated - 2 poles - 250A
In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

E Interrupt Rating @ 480V


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 

F LT, ST, and I


LT, ST, I, and GF
-
-
PGME2ATSB0250
PGME2ATSE0250
PGMN2ATSB0250
PGMN2ATSE0250
PGMH2ATSB0250
PGMH2ATSE0250
PGML2ATSB0250
PGML2ATSE0250
PGMP2ATSB0250
PGMP2ATSE0250
ST and I - PGME2ATSF0250 PGMN2ATSF0250 PGMH2ATSF0250 PGML2ATSF0250 PGMP2ATSF0250
ST, I, and GF - PGME2ATSH0250 PGMN2ATSH0250 PGMH2ATSH0250 PGML2ATSH0250 PGMP2ATSH0250

G PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I - PGME2ATAJ0250 PGMN2ATAJ0250 PGMH2ATAJ0250 PGML2ATAJ0250 PGMP2ATAJ0250
LT, ST, I, and GF - PGME2ATAK0250 PGMN2ATAK0250 PGMH2ATAK0250 PGML2ATAK0250 PGMP2ATAK0250
LT, ST, I, and GF alarm - PGME2ATAL0250 PGMN2ATAL0250 PGMH2ATAL0250 PGML2ATAL0250 PGMP2ATAL0250

X LT, ST, I, and GF (defeatable) - PGME2ATAM0250 PGMN2ATAM0250 PGMH2ATAM0250 PGML2ATAM0250 PGMP2ATAM0250

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I - PGME2ATEJ0250 PGMN2ATEJ0250 PGMH2ATEJ0250 PGML2ATEJ0250 PGMP2ATEJ0250
LT, ST, I, and GF - PGME2ATEK0250 PGMN2ATEK0250 PGMH2ATEK0250 PGML2ATEK0250 PGMP2ATEK0250
LT, ST, I, and GF alarm - PGME2ATEL0250 PGMN2ATEL0250 PGMH2ATEL0250 PGML2ATEL0250 PGMP2ATEL0250
LT, ST, I, and GF (defeatable) - PGME2ATEM0250 PGMN2ATEM0250 PGMH2ATEM0250 PGML2ATEM0250 PGMP2ATEM0250

A.28
GuardEon
250A complete circuit breaker - GuardEon PG600

Global with UL PG600 - Standard UL rated - 3 poles - 250A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PGFC3ATSB0250 PGFE3ATSB0250 PGFN3ATSB0250 PGFH3ATSB0250 PGFL3ATSB0250 PGFP3ATSB0250
LT, ST, I, and GF PGFC3ATSE0250 PGFE3ATSE0250 PGFN3ATSE0250 PGFH3ATSE0250 PGFL3ATSE0250 PGFP3ATSE0250
ST and I PGFC3ATSF0250 PGFE3ATSF0250 PGFN3ATSF0250 PGFH3ATSF0250 PGFL3ATSF0250 PGFP3ATSF0250
ST, I, and GF PGFC3ATSH0250 PGFE3ATSH0250 PGFN3ATSH0250 PGFH3ATSH0250 PGFL3ATSH0250 PGFP3ATSH0250

PremEon G Current electronic trip units - Fully adjustable settings

Order codes
LT, ST, and I PGFC3ATAJ0250 PGFE3ATAJ0250 PGFN3ATAJ0250 PGFH3ATAJ0250 PGFL3ATAJ0250 PGFP3ATAJ0250
LT, ST, I, and GF PGFC3ATAK0250 PGFE3ATAK0250 PGFN3ATAK0250 PGFH3ATAK0250 PGFL3ATAK0250 PGFP3ATAK0250
LT, ST, I, and GF alarm PGFC3ATAL0250 PGFE3ATAL0250 PGFN3ATAL0250 PGFH3ATAL0250 PGFL3ATAL0250 PGFP3ATAL0250
LT, ST, I, and GF (defeatable) PGFC3ATAM0250 PGFE3ATAM0250 PGFN3ATAM0250 PGFH3ATAM0250 PGFL3ATAM0250 PGFP3ATAM0250

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PGFC3ATEJ0250 PGFE3ATEJ0250 PGFN3ATEJ0250 PGFH3ATEJ0250 PGFL3ATEJ0250 PGFP3ATEJ0250
LT, ST, I, and GF PGFC3ATEK0250 PGFE3ATEK0250 PGFN3ATEK0250 PGFH3ATEK0250 PGFL3ATEK0250 PGFP3ATEK0250
LT, ST, I, and GF alarm PGFC3ATEL0250 PGFE3ATEL0250 PGFN3ATEL0250 PGFH3ATEL0250 PGFL3ATEL0250 PGFP3ATEL0250
LT, ST, I, and GF (defeatable) PGFC3ATEM0250 PGFE3ATEM0250 PGFN3ATEM0250 PGFH3ATEM0250 PGFL3ATEM0250 PGFP3ATEM0250

PremEon G Current electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC3ATAJ0250 PGGE3ATAJ0250 PGGN3ATAJ0250 PGGH3ATAJ0250 PGGL3ATAJ0250 PGGP3ATAJ0250
Intro
LT, ST, I, and GF PGGC3ATAK0250 PGGE3ATAK0250 PGGN3ATAK0250 PGGH3ATAK0250 PGGL3ATAK0250 PGGP3ATAK0250
LT, ST, I, and GF alarm PGGC3ATAL0250 PGGE3ATAL0250 PGGN3ATAL0250 PGGH3ATAL0250 PGGL3ATAL0250 PGGP3ATAL0250
LT, ST, I, and GF (defeatable) PGGC3ATAM0250 PGGE3ATAM0250 PGGN3ATAM0250 PGGH3ATAM0250 PGGL3ATAM0250 PGGP3ATAM0250
A
PremEon G Advanced Metering electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC3ATEJ0250 PGGE3ATEJ0250 PGGN3ATEJ0250 PGGH3ATEJ0250 PGGL3ATEJ0250 PGGP3ATEJ0250
LT, ST, I, and GF PGGC3ATEK0250 PGGE3ATEK0250 PGGN3ATEK0250 PGGH3ATEK0250 PGGL3ATEK0250 PGGP3ATEK0250
LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PGGC3ATEL0250
PGGC3ATEM0250
PGGE3ATEL0250
PGGE3ATEM0250
PGGN3ATEL0250
PGGN3ATEM0250
PGGH3ATEL0250
PGGH3ATEM0250
PGGL3ATEL0250
PGGL3ATEM0250
PGGP3ATEL0250
PGGP3ATEM0250
B

D
Global with UL PG600 - 100% UL rated - 3 poles - 250A
In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V E


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I
LT, ST, I, and GF
PGMC3ATSB0250
PGMC3ATSE0250
PGME3ATSB0250
PGME3ATSE0250
PGMN3ATSB0250
PGMN3ATSE0250
PGMH3ATSB0250
PGMH3ATSE0250
PGML3ATSB0250
PGML3ATSE0250
PGMP3ATSB0250
PGMP3ATSE0250 F
ST and I PGMC3ATSF0250 PGME3ATSF0250 PGMN3ATSF0250 PGMH3ATSF0250 PGML3ATSF0250 PGMP3ATSF0250
ST, I, and GF PGMC3ATSH0250 PGME3ATSH0250 PGMN3ATSH0250 PGMH3ATSH0250 PGML3ATSH0250 PGMP3ATSH0250

PremEon G Current electronic trip units - Fully adjustable settings G


LT, ST, and I PGMC3ATAJ0250 PGME3ATAJ0250 PGMN3ATAJ0250 PGMH3ATAJ0250 PGML3ATAJ0250 PGMP3ATAJ0250
LT, ST, I, and GF PGMC3ATAK0250 PGME3ATAK0250 PGMN3ATAK0250 PGMH3ATAK0250 PGML3ATAK0250 PGMP3ATAK0250
LT, ST, I, and GF alarm PGMC3ATAL0250 PGME3ATAL0250 PGMN3ATAL0250 PGMH3ATAL0250 PGML3ATAL0250 PGMP3ATAL0250
LT, ST, I, and GF (defeatable) PGMC3ATAM0250 PGME3ATAM0250 PGMN3ATAM0250 PGMH3ATAM0250 PGML3ATAM0250 PGMP3ATAM0250
X
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PGMC3ATEJ0250 PGME3ATEJ0250 PGMN3ATEJ0250 PGMH3ATEJ0250 PGML3ATEJ0250 PGMP3ATEJ0250
LT, ST, I, and GF PGMC3ATEK0250 PGME3ATEK0250 PGMN3ATEK0250 PGMH3ATEK0250 PGML3ATEK0250 PGMP3ATEK0250
LT, ST, I, and GF alarm PGMC3ATEL0250 PGME3ATEL0250 PGMN3ATEL0250 PGMH3ATEL0250 PGML3ATEL0250 PGMP3ATEL0250
LT, ST, I, and GF (defeatable) PGMC3ATEM0250 PGME3ATEM0250 PGMN3ATEM0250 PGMH3ATEM0250 PGML3ATEM0250 PGMP3ATEM0250

A.29
GuardEon
250A complete circuit breaker - GuardEon PG600

Global with UL PG600 - Standard UL rated - 4 poles - 250A(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PGFC4ATSB0250 PGFE4ATSB0250 PGFN4ATSB0250 PGFH4ATSB0250 PGFL4ATSB0250 PGFP4ATSB0250
LT, ST, I, and GF PGFC4ATSE0250 PGFE4ATSE0250 PGFN4ATSE0250 PGFH4ATSE0250 PGFL4ATSE0250 PGFP4ATSE0250
ST and I PGFC4ATSF0250 PGFE4ATSF0250 PGFN4ATSF0250 PGFH4ATSF0250 PGFL4ATSF0250 PGFP4ATSF0250
ST, I, and GF PGFC4ATSH0250 PGFE4ATSH0250 PGFN4ATSH0250 PGFH4ATSH0250 PGFL4ATSH0250 PGFP4ATSH0250

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PGFC4ATAJ0250 PGFE4ATAJ0250 PGFN4ATAJ0250 PGFH4ATAJ0250 PGFL4ATAJ0250 PGFP4ATAJ0250
LT, ST, I, and GF PGFC4ATAK0250 PGFE4ATAK0250 PGFN4ATAK0250 PGFH4ATAK0250 PGFL4ATAK0250 PGFP4ATAK0250
GuardEon

LT, ST, I, and GF alarm PGFC4ATAL0250 PGFE4ATAL0250 PGFN4ATAL0250 PGFH4ATAL0250 PGFL4ATAL0250 PGFP4ATAL0250
LT, ST, I, and GF (defeatable) PGFC4ATAM0250 PGFE4ATAM0250 PGFN4ATAM0250 PGFH4ATAM0250 PGFL4ATAM0250 PGFP4ATAM0250

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PGFC4ATEJ0250 PGFE4ATEJ0250 PGFN4ATEJ0250 PGFH4ATEJ0250 PGFL4ATEJ0250 PGFP4ATEJ0250
LT, ST, I, and GF PGFC4ATEK0250 PGFE4ATEK0250 PGFN4ATEK0250 PGFH4ATEK0250 PGFL4ATEK0250 PGFP4ATEK0250
LT, ST, I, and GF alarm PGFC4ATEL0250 PGFE4ATEL0250 PGFN4ATEL0250 PGFH4ATEL0250 PGFL4ATEL0250 PGFP4ATEL0250
LT, ST, I, and GF (defeatable) PGFC4ATEM0250 PGFE4ATEM0250 PGFN4ATEM0250 PGFH4ATEM0250 PGFL4ATEM0250 PGFP4ATEM0250

Intro PremEon G Current electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC4ATAJ0250 PGGE4ATAJ0250 PGGN4ATAJ0250 PGGH4ATAJ0250 PGGL4ATAJ0250 PGGP4ATAJ0250
LT, ST, I, and GF PGGC4ATAK0250 PGGE4ATAK0250 PGGN4ATAK0250 PGGH4ATAK0250 PGGL4ATAK0250 PGGP4ATAK0250
LT, ST, I, and GF alarm PGGC4ATAL0250 PGGE4ATAL0250 PGGN4ATAL0250 PGGH4ATAL0250 PGGL4ATAL0250 PGGP4ATAL0250
LT, ST, I, and GF (defeatable) PGGC4ATAM0250 PGGE4ATAM0250 PGGN4ATAM0250 PGGH4ATAM0250 PGGL4ATAM0250 PGGP4ATAM0250
A
PremEon G Advanced Metering electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC4ATEJ0250 PGGE4ATEJ0250 PGGN4ATEJ0250 PGGH4ATEJ0250 PGGL4ATEJ0250 PGGP4ATEJ0250
LT, ST, I, and GF PGGC4ATEK0250 PGGE4ATEK0250 PGGN4ATEK0250 PGGH4ATEK0250 PGGL4ATEK0250 PGGP4ATEK0250
B LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PGGC4ATEL0250
PGGC4ATEM0250
PGGE4ATEL0250
PGGE4ATEM0250
PGGN4ATEL0250
PGGN4ATEM0250
PGGH4ATEL0250
PGGH4ATEM0250
PGGL4ATEL0250
PGGL4ATEM0250
PGGP4ATEL0250
PGGP4ATEM0250

D
Global with UL PG600 - 100% UL rated - 4 poles - 250A(1)
In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

E Interrupt Rating @ 480V


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 

F LT, ST, and I


LT, ST, I, and GF
PGMC4ATSB0250
PGMC4ATSE0250
PGME4ATSB0250
PGME4ATSE0250
PGMN4ATSB0250
PGMN4ATSE0250
PGMH4ATSB0250
PGMH4ATSE0250
PGML4ATSB0250
PGML4ATSE0250
PGMP4ATSB0250
PGMP4ATSE0250
ST and I PGMC4ATSF0250 PGME4ATSF0250 PGMN4ATSF0250 PGMH4ATSF0250 PGML4ATSF0250 PGMP4ATSF0250
ST, I, and GF PGMC4ATSH0250 PGME4ATSH0250 PGMN4ATSH0250 PGMH4ATSH0250 PGML4ATSH0250 PGMP4ATSH0250

G PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PGMC4ATAJ0250 PGME4ATAJ0250 PGMN4ATAJ0250 PGMH4ATAJ0250 PGML4ATAJ0250 PGMP4ATAJ0250
LT, ST, I, and GF PGMC4ATAK0250 PGME4ATAK0250 PGMN4ATAK0250 PGMH4ATAK0250 PGML4ATAK0250 PGMP4ATAK0250
LT, ST, I, and GF alarm PGMC4ATAL0250 PGME4ATAL0250 PGMN4ATAL0250 PGMH4ATAL0250 PGML4ATAL0250 PGMP4ATAL0250

X LT, ST, I, and GF (defeatable) PGMC4ATAM0250 PGME4ATAM0250 PGMN4ATAM0250 PGMH4ATAM0250 PGML4ATAM0250 PGMP4ATAM0250

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PGMC4ATEJ0250 PGME4ATEJ0250 PGMN4ATEJ0250 PGMH4ATEJ0250 PGML4ATEJ0250 PGMP4ATEJ0250
LT, ST, I, and GF PGMC4ATEK0250 PGME4ATEK0250 PGMN4ATEK0250 PGMH4ATEK0250 PGML4ATEK0250 PGMP4ATEK0250
LT, ST, I, and GF alarm PGMC4ATEL0250 PGME4ATEL0250 PGMN4ATEL0250 PGMH4ATEL0250 PGML4ATEL0250 PGMP4ATEL0250
LT, ST, I, and GF (defeatable) PGMC4ATEM0250 PGME4ATEM0250 PGMN4ATEM0250 PGMH4ATEM0250 PGML4ATEM0250 PGMP4ATEM0250

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.30
GuardEon
400A complete circuit breaker - GuardEon PG600

Global with UL PG600 - Standard UL rated - 2 poles - 400A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PGFC2ATSB0400 PGFE2ATSB0400 PGFN2ATSB0400 PGFH2ATSB0400 PGFL2ATSB0400 PGFP2ATSB0400
LT, ST, I, and GF PGFC2ATSE0400 PGFE2ATSE0400 PGFN2ATSE0400 PGFH2ATSE0400 PGFL2ATSE0400 PGFP2ATSE0400
ST and I PGFC2ATSF0400 PGFE2ATSF0400 PGFN2ATSF0400 PGFH2ATSF0400 PGFL2ATSF0400 PGFP2ATSF0400
ST, I, and GF PGFC2ATSH0400 PGFE2ATSH0400 PGFN2ATSH0400 PGFH2ATSH0400 PGFL2ATSH0400 PGFP2ATSH0400

PremEon G Current electronic trip units - Fully adjustable settings

Order codes
LT, ST, and I PGFC2ATAJ0400 PGFE2ATAJ0400 PGFN2ATAJ0400 PGFH2ATAJ0400 PGFL2ATAJ0400 PGFP2ATAJ0400
LT, ST, I, and GF PGFC2ATAK0400 PGFE2ATAK0400 PGFN2ATAK0400 PGFH2ATAK0400 PGFL2ATAK0400 PGFP2ATAK0400
LT, ST, I, and GF alarm PGFC2ATAL0400 PGFE2ATAL0400 PGFN2ATAL0400 PGFH2ATAL0400 PGFL2ATAL0400 PGFP2ATAL0400
LT, ST, I, and GF (defeatable) PGFC2ATAM0400 PGFE2ATAM0400 PGFN2ATAM0400 PGFH2ATAM0400 PGFL2ATAM0400 PGFP2ATAM0400

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PGFC2ATEJ0400 PGFE2ATEJ0400 PGFN2ATEJ0400 PGFH2ATEJ0400 PGFL2ATEJ0400 PGFP2ATEJ0400
LT, ST, I, and GF PGFC2ATEK0400 PGFE2ATEK0400 PGFN2ATEK0400 PGFH2ATEK0400 PGFL2ATEK0400 PGFP2ATEK0400
LT, ST, I, and GF alarm PGFC2ATEL0400 PGFE2ATEL0400 PGFN2ATEL0400 PGFH2ATEL0400 PGFL2ATEL0400 PGFP2ATEL0400
LT, ST, I, and GF (defeatable) PGFC2ATEM0400 PGFE2ATEM0400 PGFN2ATEM0400 PGFH2ATEM0400 PGFL2ATEM0400 PGFP2ATEM0400

PremEon G Current electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC2ATAJ0400 PGGE2ATAJ0400 PGGN2ATAJ0400 PGGH2ATAJ0400 PGGL2ATAJ0400 PGGP2ATAJ0400
Intro
LT, ST, I, and GF PGGC2ATAK0400 PGGE2ATAK0400 PGGN2ATAK0400 PGGH2ATAK0400 PGGL2ATAK0400 PGGP2ATAK0400
LT, ST, I, and GF alarm PGGC2ATAL0400 PGGE2ATAL0400 PGGN2ATAL0400 PGGH2ATAL0400 PGGL2ATAL0400 PGGP2ATAL0400
LT, ST, I, and GF (defeatable) PGGC2ATAM0400 PGGE2ATAM0400 PGGN2ATAM0400 PGGH2ATAM0400 PGGL2ATAM0400 PGGP2ATAM0400
A
PremEon G Advanced Metering electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC2ATEJ0400 PGGE2ATEJ0400 PGGN2ATEJ0400 PGGH2ATEJ0400 PGGL2ATEJ0400 PGGP2ATEJ0400
LT, ST, I, and GF PGGC2ATEK0400 PGGE2ATEK0400 PGGN2ATEK0400 PGGH2ATEK0400 PGGL2ATEK0400 PGGP2ATEK0400
LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PGGC2ATEL0400
PGGC2ATEM0400
PGGE2ATEL0400
PGGE2ATEM0400
PGGN2ATEL0400
PGGN2ATEM0400
PGGH2ATEL0400
PGGH2ATEM0400
PGGL2ATEL0400
PGGL2ATEM0400
PGGP2ATEL0400
PGGP2ATEM0400
B

D
Global with UL PG600 - 100% UL rated - 2 poles - 400A
In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V E


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I
LT, ST, I, and GF
PGMC2ATSB0400
PGMC2ATSE0400
PGME2ATSB0400
PGME2ATSE0400
PGMN2ATSB0400
PGMN2ATSE0400
PGMH2ATSB0400
PGMH2ATSE0400
PGML2ATSB0400
PGML2ATSE0400
PGMP2ATSB0400
PGMP2ATSE0400 F
ST and I PGMC2ATSF0400 PGME2ATSF0400 PGMN2ATSF0400 PGMH2ATSF0400 PGML2ATSF0400 PGMP2ATSF0400
ST, I, and GF PGMC2ATSH0400 PGME2ATSH0400 PGMN2ATSH0400 PGMH2ATSH0400 PGML2ATSH0400 PGMP2ATSH0400

PremEon G Current electronic trip units - Fully adjustable settings G


LT, ST, and I PGMC2ATAJ0400 PGME2ATAJ0400 PGMN2ATAJ0400 PGMH2ATAJ0400 PGML2ATAJ0400 PGMP2ATAJ0400
LT, ST, I, and GF PGMC2ATAK0400 PGME2ATAK0400 PGMN2ATAK0400 PGMH2ATAK0400 PGML2ATAK0400 PGMP2ATAK0400
LT, ST, I, and GF alarm PGMC2ATAL0400 PGME2ATAL0400 PGMN2ATAL0400 PGMH2ATAL0400 PGML2ATAL0400 PGMP2ATAL0400
LT, ST, I, and GF (defeatable) PGMC2ATAM0400 PGME2ATAM0400 PGMN2ATAM0400 PGMH2ATAM0400 PGML2ATAM0400 PGMP2ATAM0400
X
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PGMC2ATEJ0400 PGME2ATEJ0400 PGMN2ATEJ0400 PGMH2ATEJ0400 PGML2ATEJ0400 PGMP2ATEJ0400
LT, ST, I, and GF PGMC2ATEK0400 PGME2ATEK0400 PGMN2ATEK0400 PGMH2ATEK0400 PGML2ATEK0400 PGMP2ATEK0400
LT, ST, I, and GF alarm PGMC2ATEL0400 PGME2ATEL0400 PGMN2ATEL0400 PGMH2ATEL0400 PGML2ATEL0400 PGMP2ATEL0400
LT, ST, I, and GF (defeatable) PGMC2ATEM0400 PGME2ATEM0400 PGMN2ATEM0400 PGMH2ATEM0400 PGML2ATEM0400 PGMP2ATEM0400

A.31
GuardEon
400A complete circuit breaker - GuardEon PG600

Global with UL PG600 - Standard UL rated - 3 poles - 400A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PGFC3ATSB0400 PGFE3ATSB0400 PGFN3ATSB0400 PGFH3ATSB0400 PGFL3ATSB0400 PGFP3ATSB0400
LT, ST, I, and GF PGFC3ATSE0400 PGFE3ATSE0400 PGFN3ATSE0400 PGFH3ATSE0400 PGFL3ATSE0400 PGFP3ATSE0400
ST and I PGFC3ATSF0400 PGFE3ATSF0400 PGFN3ATSF0400 PGFH3ATSF0400 PGFL3ATSF0400 PGFP3ATSF0400
ST, I, and GF PGFC3ATSH0400 PGFE3ATSH0400 PGFN3ATSH0400 PGFH3ATSH0400 PGFL3ATSH0400 PGFP3ATSH0400

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PGFC3ATAJ0400 PGFE3ATAJ0400 PGFN3ATAJ0400 PGFH3ATAJ0400 PGFL3ATAJ0400 PGFP3ATAJ0400
LT, ST, I, and GF PGFC3ATAK0400 PGFE3ATAK0400 PGFN3ATAK0400 PGFH3ATAK0400 PGFL3ATAK0400 PGFP3ATAK0400
GuardEon

LT, ST, I, and GF alarm PGFC3ATAL0400 PGFE3ATAL0400 PGFN3ATAL0400 PGFH3ATAL0400 PGFL3ATAL0400 PGFP3ATAL0400
LT, ST, I, and GF (defeatable) PGFC3ATAM0400 PGFE3ATAM0400 PGFN3ATAM0400 PGFH3ATAM0400 PGFL3ATAM0400 PGFP3ATAM0400

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PGFC3ATEJ0400 PGFE3ATEJ0400 PGFN3ATEJ0400 PGFH3ATEJ0400 PGFL3ATEJ0400 PGFP3ATEJ0400
LT, ST, I, and GF PGFC3ATEK0400 PGFE3ATEK0400 PGFN3ATEK0400 PGFH3ATEK0400 PGFL3ATEK0400 PGFP3ATEK0400
LT, ST, I, and GF alarm PGFC3ATEL0400 PGFE3ATEL0400 PGFN3ATEL0400 PGFH3ATEL0400 PGFL3ATEL0400 PGFP3ATEL0400
LT, ST, I, and GF (defeatable) PGFC3ATEM0400 PGFE3ATEM0400 PGFN3ATEM0400 PGFH3ATEM0400 PGFL3ATEM0400 PGFP3ATEM0400

Intro PremEon G Current electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC3ATAJ0400 PGGE3ATAJ0400 PGGN3ATAJ0400 PGGH3ATAJ0400 PGGL3ATAJ0400 PGGP3ATAJ0400
LT, ST, I, and GF PGGC3ATAK0400 PGGE3ATAK0400 PGGN3ATAK0400 PGGH3ATAK0400 PGGL3ATAK0400 PGGP3ATAK0400
LT, ST, I, and GF alarm PGGC3ATAL0400 PGGE3ATAL0400 PGGN3ATAL0400 PGGH3ATAL0400 PGGL3ATAL0400 PGGP3ATAL0400
LT, ST, I, and GF (defeatable) PGGC3ATAM0400 PGGE3ATAM0400 PGGN3ATAM0400 PGGH3ATAM0400 PGGL3ATAM0400 PGGP3ATAM0400
A
PremEon G Advanced Metering electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC3ATEJ0400 PGGE3ATEJ0400 PGGN3ATEJ0400 PGGH3ATEJ0400 PGGL3ATEJ0400 PGGP3ATEJ0400
LT, ST, I, and GF PGGC3ATEK0400 PGGE3ATEK0400 PGGN3ATEK0400 PGGH3ATEK0400 PGGL3ATEK0400 PGGP3ATEK0400
B LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PGGC3ATEL0400
PGGC3ATEM0400
PGGE3ATEL0400
PGGE3ATEM0400
PGGN3ATEL0400
PGGN3ATEM0400
PGGH3ATEL0400
PGGH3ATEM0400
PGGL3ATEL0400
PGGL3ATEM0400
PGGP3ATEL0400
PGGP3ATEM0400

D
Global with UL PG600 - 100% UL rated - 3 poles - 400A
In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

E Interrupt Rating @ 480V


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 

F LT, ST, and I


LT, ST, I, and GF
PGMC3ATSB0400
PGMC3ATSE0400
PGME3ATSB0400
PGME3ATSE0400
PGMN3ATSB0400
PGMN3ATSE0400
PGMH3ATSB0400
PGMH3ATSE0400
PGML3ATSB0400
PGML3ATSE0400
PGMP3ATSB0400
PGMP3ATSE0400
ST and I PGMC3ATSF0400 PGME3ATSF0400 PGMN3ATSF0400 PGMH3ATSF0400 PGML3ATSF0400 PGMP3ATSF0400
ST, I, and GF PGMC3ATSH0400 PGME3ATSH0400 PGMN3ATSH0400 PGMH3ATSH0400 PGML3ATSH0400 PGMP3ATSH0400

G PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PGMC3ATAJ0400 PGME3ATAJ0400 PGMN3ATAJ0400 PGMH3ATAJ0400 PGML3ATAJ0400 PGMP3ATAJ0400
LT, ST, I, and GF PGMC3ATAK0400 PGME3ATAK0400 PGMN3ATAK0400 PGMH3ATAK0400 PGML3ATAK0400 PGMP3ATAK0400
LT, ST, I, and GF alarm PGMC3ATAL0400 PGME3ATAL0400 PGMN3ATAL0400 PGMH3ATAL0400 PGML3ATAL0400 PGMP3ATAL0400

X LT, ST, I, and GF (defeatable) PGMC3ATAM0400 PGME3ATAM0400 PGMN3ATAM0400 PGMH3ATAM0400 PGML3ATAM0400 PGMP3ATAM0400

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PGMC3ATEJ0400 PGME3ATEJ0400 PGMN3ATEJ0400 PGMH3ATEJ0400 PGML3ATEJ0400 PGMP3ATEJ0400
LT, ST, I, and GF PGMC3ATEK0400 PGME3ATEK0400 PGMN3ATEK0400 PGMH3ATEK0400 PGML3ATEK0400 PGMP3ATEK0400
LT, ST, I, and GF alarm PGMC3ATEL0400 PGME3ATEL0400 PGMN3ATEL0400 PGMH3ATEL0400 PGML3ATEL0400 PGMP3ATEL0400
LT, ST, I, and GF (defeatable) PGMC3ATEM0400 PGME3ATEM0400 PGMN3ATEM0400 PGMH3ATEM0400 PGML3ATEM0400 PGMP3ATEM0400

A.32
GuardEon
400A complete circuit breaker - GuardEon PG600

Global with UL PG600 - Standard UL rated - 4 poles - 400A(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PGFC4ATSB0400 PGFE4ATSB0400 PGFN4ATSB0400 PGFH4ATSB0400 PGFL4ATSB0400 PGFP4ATSB0400
LT, ST, I, and GF PGFC4ATSE0400 PGFE4ATSE0400 PGFN4ATSE0400 PGFH4ATSE0400 PGFL4ATSE0400 PGFP4ATSE0400
ST and I PGFC4ATSF0400 PGFE4ATSF0400 PGFN4ATSF0400 PGFH4ATSF0400 PGFL4ATSF0400 PGFP4ATSF0400
ST, I, and GF PGFC4ATSH0400 PGFE4ATSH0400 PGFN4ATSH0400 PGFH4ATSH0400 PGFL4ATSH0400 PGFP4ATSH0400

PremEon G Current electronic trip units - Fully adjustable settings

Order codes
LT, ST, and I PGFC4ATAJ0400 PGFE4ATAJ0400 PGFN4ATAJ0400 PGFH4ATAJ0400 PGFL4ATAJ0400 PGFP4ATAJ0400
LT, ST, I, and GF PGFC4ATAK0400 PGFE4ATAK0400 PGFN4ATAK0400 PGFH4ATAK0400 PGFL4ATAK0400 PGFP4ATAK0400
LT, ST, I, and GF alarm PGFC4ATAL0400 PGFE4ATAL0400 PGFN4ATAL0400 PGFH4ATAL0400 PGFL4ATAL0400 PGFP4ATAL0400
LT, ST, I, and GF (defeatable) PGFC4ATAM0400 PGFE4ATAM0400 PGFN4ATAM0400 PGFH4ATAM0400 PGFL4ATAM0400 PGFP4ATAM0400

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PGFC4ATEJ0400 PGFE4ATEJ0400 PGFN4ATEJ0400 PGFH4ATEJ0400 PGFL4ATEJ0400 PGFP4ATEJ0400
LT, ST, I, and GF PGFC4ATEK0400 PGFE4ATEK0400 PGFN4ATEK0400 PGFH4ATEK0400 PGFL4ATEK0400 PGFP4ATEK0400
LT, ST, I, and GF alarm PGFC4ATEL0400 PGFE4ATEL0400 PGFN4ATEL0400 PGFH4ATEL0400 PGFL4ATEL0400 PGFP4ATEL0400
LT, ST, I, and GF (defeatable) PGFC4ATEM0400 PGFE4ATEM0400 PGFN4ATEM0400 PGFH4ATEM0400 PGFL4ATEM0400 PGFP4ATEM0400

PremEon G Current electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC4ATAJ0400 PGGE4ATAJ0400 PGGN4ATAJ0400 PGGH4ATAJ0400 PGGL4ATAJ0400 PGGP4ATAJ0400
Intro
LT, ST, I, and GF PGGC4ATAK0400 PGGE4ATAK0400 PGGN4ATAK0400 PGGH4ATAK0400 PGGL4ATAK0400 PGGP4ATAK0400
LT, ST, I, and GF alarm PGGC4ATAL0400 PGGE4ATAL0400 PGGN4ATAL0400 PGGH4ATAL0400 PGGL4ATAL0400 PGGP4ATAL0400
LT, ST, I, and GF (defeatable) PGGC4ATAM0400 PGGE4ATAM0400 PGGN4ATAM0400 PGGH4ATAM0400 PGGL4ATAM0400 PGGP4ATAM0400
A
PremEon G Advanced Metering electronic trip units - extended instantaneous - Fully adjustable settings
LT, ST, and I PGGC4ATEJ0400 PGGE4ATEJ0400 PGGN4ATEJ0400 PGGH4ATEJ0400 PGGL4ATEJ0400 PGGP4ATEJ0400
LT, ST, I, and GF PGGC4ATEK0400 PGGE4ATEK0400 PGGN4ATEK0400 PGGH4ATEK0400 PGGL4ATEK0400 PGGP4ATEK0400
LT, ST, I, and GF alarm
LT, ST, I, and GF (defeatable)
PGGC4ATEL0400
PGGC4ATEM0400
PGGE4ATEL0400
PGGE4ATEM0400
PGGN4ATEL0400
PGGN4ATEM0400
PGGH4ATEL0400
PGGH4ATEM0400
PGGL4ATEL0400
PGGL4ATEM0400
PGGP4ATEL0400
PGGP4ATEM0400
B

D
Global with UL PG600 - 100% UL rated - 4 poles - 400A(1)
In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V E


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I
LT, ST, I, and GF
PGMC4ATSB0400
PGMC4ATSE0400
PGME4ATSB0400
PGME4ATSE0400
PGMN4ATSB0400
PGMN4ATSE0400
PGMH4ATSB0400
PGMH4ATSE0400
PGML4ATSB0400
PGML4ATSE0400
PGMP4ATSB0400
PGMP4ATSE0400 F
ST and I PGMC4ATSF0400 PGME4ATSF0400 PGMN4ATSF0400 PGMH4ATSF0400 PGML4ATSF0400 PGMP4ATSF0400
ST, I, and GF PGMC4ATSH0400 PGME4ATSH0400 PGMN4ATSH0400 PGMH4ATSH0400 PGML4ATSH0400 PGMP4ATSH0400

PremEon G Current electronic trip units - Fully adjustable settings G


LT, ST, and I PGMC4ATAJ0400 PGME4ATAJ0400 PGMN4ATAJ0400 PGMH4ATAJ0400 PGML4ATAJ0400 PGMP4ATAJ0400
LT, ST, I, and GF PGMC4ATAK0400 PGME4ATAK0400 PGMN4ATAK0400 PGMH4ATAK0400 PGML4ATAK0400 PGMP4ATAK0400
LT, ST, I, and GF alarm PGMC4ATAL0400 PGME4ATAL0400 PGMN4ATAL0400 PGMH4ATAL0400 PGML4ATAL0400 PGMP4ATAL0400
LT, ST, I, and GF (defeatable) PGMC4ATAM0400 PGME4ATAM0400 PGMN4ATAM0400 PGMH4ATAM0400 PGML4ATAM0400 PGMP4ATAM0400
X
PremEon G Advanced Metering electronic trip units - Fully adjustable settings
LT, ST, and I PGMC4ATEJ0400 PGME4ATEJ0400 PGMN4ATEJ0400 PGMH4ATEJ0400 PGML4ATEJ0400 PGMP4ATEJ0400
LT, ST, I, and GF PGMC4ATEK0400 PGME4ATEK0400 PGMN4ATEK0400 PGMH4ATEK0400 PGML4ATEK0400 PGMP4ATEK0400
LT, ST, I, and GF alarm PGMC4ATEL0400 PGME4ATEL0400 PGMN4ATEL0400 PGMH4ATEL0400 PGML4ATEL0400 PGMP4ATEL0400
LT, ST, I, and GF (defeatable) PGMC4ATEM0400 PGME4ATEM0400 PGMN4ATEM0400 PGMH4ATEM0400 PGML4ATEM0400 PGMP4ATEM0400

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.33
GuardEon
600A complete circuit breaker - GuardEon PG600

Global with UL PG600 - Standard UL rated - 2 poles - 600A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PGAC2ATSB0600 PGAE2ATSB0600 PGAN2ATSB0600 PGAH2ATSB0600 PGAL2ATSB0600 PGAP2ATSB0600
LT, ST, I, and GF PGAC2ATSE0600 PGAE2ATSE0600 PGAN2ATSE0600 PGAH2ATSE0600 PGAL2ATSE0600 PGAP2ATSE0600
ST and I PGAC2ATSF0600 PGAE2ATSF0600 PGAN2ATSF0600 PGAH2ATSF0600 PGAL2ATSF0600 PGAP2ATSF0600
ST, I, and GF PGAC2ATSH0600 PGAE2ATSH0600 PGAN2ATSH0600 PGAH2ATSH0600 PGAL2ATSH0600 PGAP2ATSH0600

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PGAC2ATAJ0600 PGAE2ATAJ0600 PGAN2ATAJ0600 PGAH2ATAJ0600 PGAL2ATAJ0600 PGAP2ATAJ0600
LT, ST, I, and GF PGAC2ATAK0600 PGAE2ATAK0600 PGAN2ATAK0600 PGAH2ATAK0600 PGAL2ATAK0600 PGAP2ATAK0600
GuardEon

LT, ST, I, and GF alarm PGAC2ATAL0600 PGAE2ATAL0600 PGAN2ATAL0600 PGAH2ATAL0600 PGAL2ATAL0600 PGAP2ATAL0600
LT, ST, I, and GF (defeatable) PGAC2ATAM0600 PGAE2ATAM0600 PGAN2ATAM0600 PGAH2ATAM0600 PGAL2ATAM0600 PGAP2ATAM0600

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PGAC2ATEJ0600 PGAE2ATEJ0600 PGAN2ATEJ0600 PGAH2ATEJ0600 PGAL2ATEJ0600 PGAP2ATEJ0600
LT, ST, I, and GF PGAC2ATEK0600 PGAE2ATEK0600 PGAN2ATEK0600 PGAH2ATEK0600 PGAL2ATEK0600 PGAP2ATEK0600
LT, ST, I, and GF alarm PGAC2ATEL0600 PGAE2ATEL0600 PGAN2ATEL0600 PGAH2ATEL0600 PGAL2ATEL0600 PGAP2ATEL0600
LT, ST, I, and GF (defeatable) PGAC2ATEM0600 PGAE2ATEM0600 PGAN2ATEM0600 PGAH2ATEM0600 PGAL2ATEM0600 PGAP2ATEM0600

Intro Global with UL PG600 - Standard UL rated - 3 poles - 600A


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V


A 25kA 35kA 65kA 100kA 150kA 200kA
PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PGAC3ATSB0600 PGAE3ATSB0600 PGAN3ATSB0600 PGAH3ATSB0600 PGAL3ATSB0600 PGAP3ATSB0600
LT, ST, I, and GF PGAC3ATSE0600 PGAE3ATSE0600 PGAN3ATSE0600 PGAH3ATSE0600 PGAL3ATSE0600 PGAP3ATSE0600
B ST and I
ST, I, and GF
PGAC3ATSF0600
PGAC3ATSH0600
PGAE3ATSF0600
PGAE3ATSH0600
PGAN3ATSF0600
PGAN3ATSH0600
PGAH3ATSF0600
PGAH3ATSH0600
PGAL3ATSF0600
PGAL3ATSH0600
PGAP3ATSF0600
PGAP3ATSH0600

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PGAC3ATAJ0600 PGAE3ATAJ0600 PGAN3ATAJ0600 PGAH3ATAJ0600 PGAL3ATAJ0600 PGAP3ATAJ0600
C LT, ST, I, and GF PGAC3ATAK0600 PGAE3ATAK0600 PGAN3ATAK0600 PGAH3ATAK0600 PGAL3ATAK0600 PGAP3ATAK0600
LT, ST, I, and GF alarm PGAC3ATAL0600 PGAE3ATAL0600 PGAN3ATAL0600 PGAH3ATAL0600 PGAL3ATAL0600 PGAP3ATAL0600
LT, ST, I, and GF (defeatable) PGAC3ATAM0600 PGAE3ATAM0600 PGAN3ATAM0600 PGAH3ATAM0600 PGAL3ATAM0600 PGAP3ATAM0600

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


D LT, ST, and I PGAC3ATEJ0600 PGAE3ATEJ0600 PGAN3ATEJ0600 PGAH3ATEJ0600 PGAL3ATEJ0600 PGAP3ATEJ0600
LT, ST, I, and GF PGAC3ATEK0600 PGAE3ATEK0600 PGAN3ATEK0600 PGAH3ATEK0600 PGAL3ATEK0600 PGAP3ATEK0600
LT, ST, I, and GF alarm PGAC3ATEL0600 PGAE3ATEL0600 PGAN3ATEL0600 PGAH3ATEL0600 PGAL3ATEL0600 PGAP3ATEL0600
LT, ST, I, and GF (defeatable) PGAC3ATEM0600 PGAE3ATEM0600 PGAN3ATEM0600 PGAH3ATEM0600 PGAL3ATEM0600 PGAP3ATEM0600
E Non-automatic circuit breaker (switch rated at 40°C) - 3 poles
PGFY3ATDU0600

F Global with UL PG600 - Standard UL rated - 4 poles - 600A(1)


In Cat. no. Cat. no. Cat. no. Cat. no. Cat. no. Cat. no.

Interrupt Rating @ 480V

G 25kA 35kA 65kA 100kA 150kA 200kA


PremEon S electronic trip units - Tracking Short-Time settings
 
LT, ST, and I PGAC4ATSB0600 PGAE4ATSB0600 PGAN4ATSB0600 PGAH4ATSB0600 PGAL4ATSB0600 PGAP4ATSB0600
LT, ST, I, and GF PGAC4ATSE0600 PGAE4ATSE0600 PGAN4ATSE0600 PGAH4ATSE0600 PGAL4ATSE0600 PGAP4ATSE0600
X ST and I
ST, I, and GF
PGAC4ATSF0600
PGAC4ATSH0600
PGAE4ATSF0600
PGAE4ATSH0600
PGAN4ATSF0600
PGAN4ATSH0600
PGAH4ATSF0600
PGAH4ATSH0600
PGAL4ATSF0600
PGAL4ATSH0600
PGAP4ATSF0600
PGAP4ATSH0600

PremEon G Current electronic trip units - Fully adjustable settings


LT, ST, and I PGAC4ATAJ0600 PGAE4ATAJ0600 PGAN4ATAJ0600 PGAH4ATAJ0600 PGAL4ATAJ0600 PGAP4ATAJ0600
LT, ST, I, and GF PGAC4ATAK0600 PGAE4ATAK0600 PGAN4ATAK0600 PGAH4ATAK0600 PGAL4ATAK0600 PGAP4ATAK0600
LT, ST, I, and GF alarm PGAC4ATAL0600 PGAE4ATAL0600 PGAN4ATAL0600 PGAH4ATAL0600 PGAL4ATAL0600 PGAP4ATAL0600
LT, ST, I, and GF (defeatable) PGAC4ATAM0600 PGAE4ATAM0600 PGAN4ATAM0600 PGAH4ATAM0600 PGAL4ATAM0600 PGAP4ATAM0600

PremEon G Advanced Metering electronic trip units - Fully adjustable settings


LT, ST, and I PGAC4ATEJ0600 PGAE4ATEJ0600 PGAN4ATEJ0600 PGAH4ATEJ0600 PGAL4ATEJ0600 PGAP4ATEJ0600
LT, ST, I, and GF PGAC4ATEK0600 PGAE4ATEK0600 PGAN4ATEK0600 PGAH4ATEK0600 PGAL4ATEK0600 PGAP4ATEK0600
LT, ST, I, and GF alarm PGAC4ATEL0600 PGAE4ATEL0600 PGAN4ATEL0600 PGAH4ATEL0600 PGAL4ATEL0600 PGAP4ATEL0600
LT, ST, I, and GF (defeatable) PGAC4ATEM0600 PGAE4ATEM0600 PGAN4ATEM0600 PGAH4ATEM0600 PGAL4ATEM0600 PGAP4ATEM0600

(1) Factory set to 100% neutral protection. Field settable to 50% or OFF.

A.34
GuardEon

B.2 Trip Unit Overview


B.3 Thermal Magnetic Trip Units
B.5 Time Current Curves
B.7 Electronic Trip Units - PremEon S The breaker Intro
B.9 Time Current Curves
B.10 Electronic Trip Units - PremEon G Order codes A
B.16 Time Current Curves
Trip units B

Components and accessories C

Technical data D

Application guide E

Wiring diagrams F

Dimensions G

Numerical Index X

B.1
GuardEon
Trip Unit Overview

Thermal Magnetic Type PremEon S - UL/cUL/IEC/CCC


LTM - Line Thermal Magnetic PremEon S - Selective Electronic Protection L(S)I

Protection Protection
• overload • overload
• short circuit • short circuit
• ground fault (optional)
Application
• Protection of the wires and Application
loads present in standard • Protection of all circuit types.
circuits. • Offers a high level of
selectivity with downstream
Trip Units

devices.

GTM - Generator Thermal Magnetic PremEon S - Selective Electronic Protection (S)I

Protection Protection
• overload • short circuit
Intro • lower range short circuit • ground fault (optional)

Application Application
•P rotection of long cable • For use in motor protection
A runs circuits
• Generator protection • The current of the circuit
that it protects needs to be
B limited (see dotted line) to
prevent overheating of the
breaker.

C
PremEon G - UL/cUL/IEC/CCC
D
PremEon G - Selective Electronic Protection LSIG

E Protection
• overload
• short circuit
•  multiple protection bands
F • ground fault (optional)

Application
G •  Protection of all circuit types.
• Offers a high level of
discrimination with
downstream devices.
X • Different modules allow the
user to expand the device.
(Programmable outputs,
alarms, communications, etc.)

B.2
GuardEon
Thermal Magnetic Trip Units

GuardEon E frame circuit breakers are available with the with a GE patented fault type indicator. The device has
thermal magnetic trip units described here. The breakers two indicator flags, one indicating an overload event
are available as a complete entity or in kit form with the (colored brown) and a second indicating either a short
frame and trip unit separate. circuit or an event triggered by an RCD (colored blue).

Each trip unit is equipped with an interchange interlock Thermal protection devices are normally calibrated at an

Trip Unit Overview


that prevents the inadvertent use of a PE250 trip unit in ambient temperature of 40 degrees centigrade.
the PE150 frame or vice versa. They are also equipped

The following versions are available:

LTM (line thermal magnetic protection)


A trip unit designed for the protection of generic loads.
It has a fixed thermal setting and an adjustable mag-
netic setting. The magnetic setting is adjustable
from 7-13 x In. (Fixed at 8 x In for ratings <70A)

Intro

GTM (generator thermal magnetic)


Suitable for the protection of generator circuits and/or long
A
cable runs. It has a fixed thermal setting and an adjustable
magnetic setting. The magnetic setting is adjustable
from 3-5 x In B

Y (non automatic - switch)


C
A ‘dummy ‘trip unit available for 150A and 250A.
No protection elements.
Designed as a switch disconnector. D

* Indicates a trademark of the General Electric Company. All other trademarks are the property of their respective owners. © 2016 General Electric Company. B.3
GuardEon
PE150 and PE250 breakers

Trip unit overview (thermal magnetic)

Thermal magnetic trip unit rating (amps)


Frames 20 25 30 40 50 60 70 80 90 100 110 125 150 200 225 250
PE150
PE250

PE Frame Thermal magnetic trip unit overview


Ir - Thermal Im - Magnetic Neutral Protection

Applicable for breaker types In pick-up band 1.05 - 1.3 Ir pick-up band ± 20% Im 4P 4T 4P 3T
Type Subtype kA @ 480V (A) min (A) max (A) min (A) max (A) (N = 100%) (N = 0%)

fixed 1 x In fixed 8 x In
Trip Units

20 20 160 =Ir
TTR 25 25 200 =Ir
30 30 240 =Ir
40 40 320 =Ir
50 50 400 =Ir
60 60 480 =Ir

fixed 1 x In adjustable 7-13 x In


LTM
70 70 490 910 =Ir
80 80 560 1040 =Ir
Intro 90
100
90 630 1170 =Ir
100 700 1300 =Ir
TTN 110 110 770 1430 =Ir
125 125 875 1625 =Ir
150 150 1050 1950 =Ir
A 175
H - 100kA

175 1225 2275 =Ir


L - 150kA
N - 65kA
C - 25kA
B - 18kA

E - 35kA

200 200 1400 2600 =Ir


225 225 1575 2925 =Ir
250 250 1750 3250 =Ir

B fixed 1 x In adjustable 3-5 In

125 125 375 625 =Ir


GTM 150 150 450 750 =Ir
200 200 600 1000 =Ir
C 225
250
225
250
675
750
1125
1250
=Ir
=Ir

adjustable 10-15 In

D Mag-
50
80
500
800
750
1200
TNX 100 1000 1500 Not Protected
Break
125 1250 1875
150 1500 2250
E 200
250
2000
2500
3000
3750
150
Y TDX Disconnector 250 No Protection

B.4
GuardEon
Time Current Curves - PE frame
Breaker PE150 LTM 20, 25, & 30A Breaker PE150 LTM 35, 40, & 50A

Breaker PE150 LTM 20, 25, & 30A Breaker PE150 LTM 35, 40, & 50A
1000.000 1000.000

100.000 100.000

Maximum Maximum
Total Clearing Time Total Clearing Time

10.000 10.000
Seconds (S)

Seconds (S)

PE frame
1.000 1.000

0.100 0.100

Intro
0.010 0.010
1 10 100 1,000 1 10 100 1,000
X Nominal Pickup X Nominal Pickup A
Trip Unit Amps Magn. Trip, Nom. RMS Sym. Amps Trip Unit Amps Magn. Trip, Nom. RMS Sym. Amps
20 160 35 280
25 200 40 320
30
Breaker PE150 LTM 60A
240 50 400
Breaker PE150 LTM 70, 80, 90, & 100A B
Breaker PE150 LTM 60A Breaker PE150 LTM 70, 80, 90, & 100A
1000.000 1000.000

100.000 100.000 D
Maximum Maximum
Total Clearing Time Total Clearing Time

E
10.000 10.000

F
Seconds (S)

Seconds (S)

1.000 1.000

0.100 0.100
X

0.010 0.010
1 10 100 1,000 1 10 100 1,000
X Nominal Pickup X Nominal Pickup

Trip Unit Amps Magn. Trip, Nom. RMS Sym. Amps Trip Unit Amps Magn. Trip, Nom. RMS Sym. Amps
60 480 70 490 595 700 805 910
80 560 680 800 920 1040
90 630 765 900 1035 1170
100 700 850 1000 1150 1300

B.5
GuardEon
Time Current Curves - PE frame
Breaker PE150 LTM 110, 125, & 150A - PE250 LTM 125 & 150A Breaker PE250 LTM 175, 200, & 225A

Breaker PE150 LTM 110, 125, & 150A - PE250 LTM 125 & 150A Breaker PE250 LTM 175, 200, & 225A
1000.000 1000.000

100.000 100.000

Maximum Maximum
Total Clearing Time Total Clearing Time

10.000 10.000
Seconds (S)

Seconds (S)
Trip Units

1.000 1.000

0.100 0.100

Intro
0.010 0.010
1 10 100 1,000 1 10 100 1,000

A X Nominal Pickup X Nominal Pickup

Trip Unit Amps Magn. Trip, Nom. RMS Sym. Amps Trip Unit Amps Magn. Trip, Nom. RMS Sym. Amps
110 770 935 1100 1265 1430 175 1225 1487.5 1750 2012.5 2275
125 875 1062.5 1250 1437.5 1625 200 1400 1700 2000 2300 2600
B 150 1050 1275 1500
Breaker PE250 LTM 250A
1725 1950 225 1575 1912.5 2250 2587.5 2925

Breaker PE250 LTM 250A


1000.000

D 100.000

Maximum
Total Clearing Time

E
10.000

F
Seconds (S)

1.000

X 0.100

0.010
1 10 100 1,000
X Nominal Pickup

Trip Unit Amps Magn. Trip, Nom. RMS Sym. Amps


250 1750 2125 2500 2875 3250

B.6
GuardEon
Time CurrentBreaker
Curves - PE frame
PE150 GTM 125 & 150A Breaker PE250 GTM 175, 200, & 225A

Breaker PE150 GTM 125 & 150A Breaker PE250 GTM 175, 200, & 225A
1000.000 1000.000

100.000 100.000

Maximum Maximum
Total Clearing Time Total Clearing Time

Electronic Trip Units


10.000 10.000
Seconds (S)

Seconds (S)
1.000 1.000

0.100 0.100

Intro
0.010 0.010
1 10 100 1,000 1 10 100 1,000
X Nominal Pickup X Nominal Pickup A
Trip Unit Amps Magn. Trip, Nom. RMS Sym. Amps Trip Unit Amps Magn. Trip, Nom. RMS Sym. Amps
125 375 435 500 560 625 175 525 609 700 784 875
150 450 522 600 672 750 200 600 696 800 896 1000
Breaker PE250 GTM 175, 200, & 225A
225 675 783 900 1008 1125 B
Breaker PE250 GTM 250A
1000.000

100.000 D
Maximum
Total Clearing Time

E
10.000

F
Seconds (S)

1.000

0.100
X

0.010
1 10 100 1,000
X Nominal Pickup

Trip Unit Amps Magn. Trip, Nom. RMS Sym. Amps


250 750 870 1000 1120 1250

B.7
GuardEon
Trip Units

Intro

C Smart, Reliable and Secure


D

B.8
GuardEon
Electronic Trip Units

PremEon S

PremEon S electronic trip units offer sophisticated PremEon S has been rigorously tested to cope with
protective functions and wide setting range for harmonic currents, electro magnetic fields, inrush cur-
reliability in all network environments. It features rents and spikes, thus preventing such phenomena as
adjustable dials to easily set protections. incorrect current measurement and nuisance tripping.

Electronic Trip Units


PremEon S is standard in GuardEon G Frame circuit Each trip unit is equipped with an interchange inter-
breakers. The trip unit is also available for the E frame lock that prevents the inadvertent installation into a
as an alternative to the thermal magnetic trip unit. frame of a different size.

Protection Accuracy
Each standard trip unit has at least two overcurrent The use of highly accurate sensing technology
protection settings and the option of ground fault. They are and of state-of-the-art electronics, reduces
interchangeable, designed to allow for future upgrades. the tolerances on expected tripping
currents and the associated time spans to a minimum.
Overcurrent Protection
• Up to 16 possible overload Integrated test kit
protection (LT) settings shown in Simply connect a standard mobile device charger(2)
amperes and ranging from 0.3 to to the micro USB port and the “TEST” button goes
live. Depress it and it checks the full electronic
1 times the chosen trip unit rating.
• A wide instantaneous protection circuit and then trips the connected breaker.
Intro
setting band of 2-13.5(1) times
the current sensor rating (In).
the LT setting, with a fixed time A
delay (varies by frame size) to
ensure selectivity.

Ground Fault B
An optional ground fault protection Diagnostics
device (GF) can be set from 0.4 The USB port also functions as a data access port,
to 1 times the chosen trip unit
rating and be used with multiple
allowing the user to verify the breaker settings, view
and recover data on last 10 fault occurrences and view
C
delay and/or I2T settings. waveform data of the last event(3). In this configuration,
the PC powers the trip unit (charger no longer needed).
D
Mag-Break Motor Each device is equipped with an LED indicator that
Circuit Protector flashes when the current reaches 0.95 times LT and
illuminates constantly when
PremEon S offers a
magnetic protection an overload trip is imminent E
only (no overload (above 1.05 times LT). The
protection (LT)) electronics also continuously
for all frame sizes. (3P3T or 4P3T) perform self diagnostics and warns the user of F
It is primarily designed to be used with thermal any defect using the LED State indicator.
relays in motor protection circuits. Ground
fault is also available on these devices. LED State Indicating
G
Blinking green Normal operation
Switches Blinking amber Near pickup (95% of LT)
GuardEon switches have several current ratings Solid amber In pickup (105% of LT) or
Trip test engaged (USB power)
from 150A to 600A. They are compatible with all
the GuardEon accessories and connections. Blinking red Diagnostic error X
1. Flash CRC error
2. Stack overflow error
3. Data flash read error
4. Actuator missing error
Alternating red/amber/green Firmware error

An integrated temperature sensor prevents the electronic


(1) Setting varies by frame. See PremEon S table.
(2) To IEC 62684 - Standard for mobile phone chargers
components from reaching temperatures that could
(3) Trip Unit Toolkit software is available online. damage the breaker or it’s surroundings.

B.9
GuardEon
PremEon range

PE and PG Selective Electronic Trip Unit PremEon S

PremEon trip unit rating (amps)


Frames 25 60 125 150 250 400 600
PE150
PE250
PG600

PremEon S Protections
Long Time (LT) Short Time (ST) Instantaneous (I) Neutral Protection Ground Fault (GF)
L(S)IG : SE
L(S)I : SB
PremEon S Trip Unit Subtypes (S)IG : SH(1)
Trip Units

(S)I : SF(1)
Frame PremEon S - electronic trip unit overview
LT ST I Neutral Protection GF
Ir setting Im setting Ii setting Ig setting
pick-up band pick-up band pick-up band 4P 4P 4P pick-up band
In ±7% Ir ±10% Im ±10% Ii 4T 3.5T 3T ±10% Ig(2)
Applicable for breaker types (A) Ii (A) 100% 50%(3) 0% (Off)
kA @ 480V min (A) max (A) Im (A) min (A) max (A) min (A) max (A)
0.3-1 x In 2-13.5 x In 0.4-1 x In
25 8 25 16 325 10 25
Intro
H - 100kA

60 18 60 36 780 Not 24 63
L - 150kA
N - 50kA
C - 25kA
B - 18kA

PE
E - 35kA

125 =Ir =Ir/2


40 125 80 1625 Protected 50 125
150 45 150 90 1950 60 160
250 80 250 160 3250 100 250
fixed 0.6 x Ii
A 0.3-1 x In 2-13.5 x In 0.4-1 x In
H - 100kA

250
P - 200kA

80 250 160 2750 50 250


L - 150kA
N - 50kA
C - 25kA

E - 35kA

400 Not
PG 125 400 250 4400 =Ir =Ir/2 80 400
Protected
0.3-1 x In 2-11 x In 0.4-1 x In
B 600 180 600 350 6000 120 600

(1) For SH, SF subtypes without LT protections, instantaneous Ii is settable from 2-10 x In in 10 steps for all frames.
(2) Ground fault pick up tolerance for PE frame is +/- 20%.
C (3) When the neutral setting is set at 50% and the LT setting is less than 0.56xIn, the trip unit will use 0.28xIn as the minimum neutral pick up value.

Available settings
D Frame Current Sensor rating (In) LT settings (Ir)
25 8 9 10 11 13 14 15 16 18 19 20 21 23 24 25 25
60 18 20 25 27 30 33 35 40 42 45 48 50 54 57 60 60
E PE 125
150
40
45
45
50
50
60
60
70
65
75
70
80
75
90
80
100
90
105
95
110
100
120
105
125
110
135
120
145
125
150
125
150
250 80 90 100 110 125 135 150 165 175 190 200 215 225 240 250 250
250 80 90 100 110 125 135 150 160 170 175 190 200 215 225 240 250
PG 400 125 150 160 180 200 225 240 250 265 280 300 320 340 350 375 400

F 600 175 200 225 250 300 325 350 375 400 425 450 475 500 550 575 600

Frame Current Sensor rating (In) Inst settings (Im = setting x In)
PE all 2 3 4 5 6 7 8 9.5 11.5 13.5 - - - - - -
G PG
250 2 3 4 5 6 7 8 9.5 11.5 13.5 - - - - - -
400, 600 2 3 4 5 6 7 8 9 10 11 - - - - - -

X Frame Current Sensor rating (In) GF settings (Ig = setting x In)


PE all 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95 1 1 - -
PG all 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95 1 1 - -

B.10
GuardEon
Time Current Curves - PE and PG frame
Breaker All frames ETU PremEon S

Breaker All frames ETU PremEon S


1000.000

Adjustable Long Time


Pickup, X sensor, see table

100.000

Clearing time at 6X LT PU
~ 8 seconds

10.000
Seconds (S)

Short Time Pickup fixed at 60%


of Instantaneous Pickup

PremEon S
1.000
Instantaneous
clearing time varies
per frame, see table

0.100 Adjustable Instantaneous


Pickup, X sensor, see table

Intro
0.010
0.1 1.0 10.0 100.0
X Sensor Rating A

B.11
GuardEon
Electronic Trip Units

PremEon G

PremEon G is an electronic trip unit offering advanced PremEon G makes adjustabillity a priority. Long time pick
protective functions that can be extended at will by the up can be set in 1 ampere increments. Long time delay is
addition of separately available modules. available in three curve shapes and multiple classes.
Designed for use with the GuardEon E & G frame sizes, Extended range options offer higher instantaneous pick up.
PremEon G can be optioned with 2 to 4 protective func- And ground fault can be included as standard ground
tions allowing a selective and fully adjustable protection fault, ground fault alarm only, or switchable ground fault.
against overloads (LT), short-circuits (ST and I), and With switchable ground fault, the user can change
ground faults (GF). between standard and ground fault alarm depending on
what the application needs.

Overload Protection - Long Time (LT)


Trip Units

The long time current pick up (Ir) or inverse time protection


againts overloads is adjustable from 0.2(1) to 1x the
current sensor’s rating (In) in 1 ampere increments. PremEon G ET U
1,000.00
The user can also define the Long Time Delay (LTD), the
amount of time to trip after detecting an overload
condition, by choosing a curve type and a time delay band.
LT curve shapes
Thermal
Intro PremEon G offers 3 curve types that simulate different
responses.
100.00 I2T
I4T
TH - thermal circuit breaker curve
I2T - GE MVT type circuit breaker curve
A I4T - fuse like curve
LTD,
10.00 6 x pickup
After the curve type is selected, the time response at a
current of 6 x Ir is set in seconds. The TH and I2T curve types
B offer many time options that can meet the tripping
requirements of UL508.
1.00
C Long Time Load Indicator LED
Located on the face of the trip unit, the LED indicates the
percent of the LT setting the circuit breaker is carrying as
well as the health status.
D 0.10
Seconds (S)

<95% 105% >105%

E
0.01
0.1 1.0 10.0 100.0
X sensor rating
F
(1) For PE frames, LT is adjustable from 0.3 to 1 x the sensor rating

Over Temperature Protection


G LED State Indicating
All PremEon G trip units have a built-in temperature sensor
Blinking green Normal operation that will trip the circuit breaker when the temperature inside
Blinking amber Near pickup (95% of LT)
Solid amber In pickup (105% of LT) or the trip unit exceeds 90°C. It thus prevents the breaker and
X Blinking red
Trip test engaged (USB power)
Diagnostic error
electrical components from overheating.
Alternating red/amber/green Firmware error
Solid green / Off Error Thermal Memory
The PremEon G is also equipped with thermal memory.
This feature remembers when an event occurred even after
the device has tripped and will trip the breaker if it is reset
until the required amount of time (12 minutes) has elapsed
for the system to cool.

B.12
GuardEon

Short-circuit protection short time (ST) Sealable cover


The short time protection defines low value short-circuit For protection against unauthorized adjustment, all
pickup current (Im) and is settable in multiples of the LT PremEon trip units feature transparent, sealable covers that
setting (Ir) in 0.1x increments. accommodate standard wire ties (max diameter of 1mm).
The cover allows the user to access and view settings but
The short time delay (STD) defines the time to trip once the does not allow them to change settings. A sealable cover
ST current is detected. It can be set with a definite time also means the breaker can be wired to the LT setting and
delay or it can be set to an ‘energy curve mode’, I2T ON, not the current sensor size.
that adds an inverse time curve to the trip time response.
The curve can be shifted to 11 different positions. HMI/LCD Display
A 5 button keypad and backlit LCD display make
Short-circuit protecton instantaneous (INST) programming and viewing status/metering displays easy.

PremEon G
Instantaneous protection defines short-circuit pickup
current for ultra fast dectection. It is settable in multiples of
the current sensor rating (In) in 0.1x increments.

Extended instantaneous breakers are also available for


higher inrush immunity applications. The maximum INST
setting is much higher than that of standard breakers for
better selective coordination.
Intro
Ground Fault Protection (GF) Input for testing, set-up
Designed for protection against indirect contact, the A micro USB port is integrated into the front of all PremEon G
ground fault function measures the vectoral sum of the trip units for easy testing, set-up and monitoring.
three phase currents and, if present, that of the neutral A
conductor. If the sum of these values exceeds the set Integrated test function
current thresholds (GF) for a period of time greater than the Simply connect a standard mobile device charger(2) to the
set time delay (GFD), the breaker is tripped. micro USB port, navigate to the “Status” screen and press
enter when “Push to Trip” is displayed. The test checks the
B
Ground fault pickup is adjustable from 0.2(1) to 1.0x the full electronic circuit and then trips the connected breaker.
current sensor rating (ln) in 0.01 x increments. Ground fault
delay is similar to short time delay in that it consists of a Set-up C
definite time delay or optionally, an ‘energy curve mode’ To set-up the breaker, the trip unit must be powered up.
with inverse slope response. The micro USB port offers an easy way to safely power the
breaker. With a standard battery pack connected, the trip
Ground fault alarm (GFA) unit screen will power up for setting. The screen can also
D
The ground fault alarm option also measures the vectoral be powered up when connected to a laptop, and settings
sum of the three phase currents (and neutral), comparing can be downloaded from the Trip Unit Toolkit software.
the values to the GF pickup and GFD settings. However, in E
the event the values exceed the thresholds and time limits,
the trip unit will send an alarm (via programmable output
contact closure). The breaker will NOT trip.
F
Switchable ground fault (GFS)
Switchable ground fault is a NEW option for PremEon G. It
allows the user to switch the ground fault protection
function back and forth between standard GF and GFA.
G
Neutral protection
Every PremEon G trip unit comes equipped with settable X
neutral protection. (For 3 pole breakers, a neutral CT is
required.) When enabled, overload, short time and
instantaneous protection is performed on the neutral
connection as well. The default setting is 100%, but it can
also be set to 50% or OFF.

(1) Min GF setting for E frame is 0.40 x In


(2) To IEC 62684 - Standard for mobile phone chargers

B.13
GuardEon
PremEon range

PE and PG Selective Electronic Trip Unit PremEon G

PremEon trip unit rating (amps)


Frames 25 60 125 150 250 400 600
PE150
PE250
PG600

PremEon G - Protections
Long Time (LT) Short Time (ST) Instantaneous (I) Neutral Protection Ground Fault (GF)
Current: AJ
Advanced Metering: EJ
PremEon G Trip Unit Subtypes
Current: AK , AL , AM
Advanced Metering: EK, EL, EM
Trip Units

Frame PremEon G - electronic trip unit overview


LT ST I Neutral Protection GF
Ir setting Im setting Ii setting Ig setting
pick-up band pick-up band pick-up band 4P 4P 4P pick-up band
In ± 7% Ir 10% Im ±10% Ii 4T 3.5T 3T ±10% Ig
(A) 100% 50% 0% (Off)
Applicable for breaker types
kA @ 415V min (A) max (A) min (A) max (A) max Ii (A) min (A) max (A)
0.3-1 x In 2-13 x Ir or OFF 1-13.5 x In 0.4-1 x In
Intro 25 8
1A steps
25
0.1x steps
16 325
0.1x steps
338
0.01 steps
10 25
H - 100kA

60 19 60 38 780 810 24 63
L - 150kA
N - 50kA
C - 25kA
B - 18kA

E - 35kA

125 38 125 76 1625 1688 50 125


150 48 150 96 1950 2025 60 160
A PE
250 75
LTD
250 150
STD
3250 3375
RELT(1) =Ir =Ir/2
Not
Protected
100
GFD
250

Clear
Definite time Temp. setting Definite time
Shape Bands time(2) (s)
min (s) max(s) pick-up band min (s) max(s)
@ 7.2 x Ir
B Thermal 1.1 - 11.2
I2T 0.9 - 10.6
1.09 - 11.1
0.89 - 10.5
0.025
I2T ON
0.442 ± 10% Ii
Ii (A)
0.042 0.442
I2T or I4T ON
I4T F1 - F22 0.53 - 137 Bands 0.1x steps Bands
1 - 11 1.5-10.0 x In 1-3

C
Frame PremEon G - electronic trip unit overview
LT ST I Neutral Protection GF
Ir setting Im setting Ii setting Ig setting
D In
pick-up band
± 7% Ir
pick-up band
±7% Im
pick-up band
±7% Ii
4P
4T
4P
3.5T
4P
3T
pick-up band
±10% Ig
(A) 100% 50% 0% (Off)
Applicable for breaker types
kA @ 415V min (A) max (A) min (A) max (A) max Ii (A) min (A) max (A)

E 0.2-1 x In
1A steps
1.5-12.5 x Ir or OFF
0.1x steps
1-13.5 x In
0.1x steps
0.4-1 x In
0.01 steps
H - 100kA

250
P - 200kA

50 250 75 3125 3375 50 250


L - 150kA
N - 65kA
C - 25kA

E - 35kA

1-11 x In
400 80 400 120 4000 4400 80 400
F 600 120
LTD
600 180
STD
6000 6600
RELT(1) Not
120
GFD
600
PG =Ir =Ir/2
Protected
Clear
Definite time Temp. setting Definite time
Shape Bands time(2) (s)
min (s) max (s) pick-up band min (s) max (s)
@ 7.2 x Ir
G Thermal 1.1 - 13.3 1.1 - 13.2
2
0.025 0.442 ± 10% Ii 0.042 0.442
I T 0.9 - 13.9 0.9 - 13.9 I2T ON Ii (A) I2T or I4T ON
I4T F1 - F22 0.54 - 137 Bands 0.1x steps Bands
1 - 11 0.6-10.0 x In 1-3

(1) RELT (Reduced Energy Let-Through) Instantaneous is for temporary use to provide faster and more sensitive protection.
Requires accessory module and 24Vdc power.
(2) Times for I4T long time delay bands are given at 2.5X Ir instead of 6X.

B.14
GuardEon
PremEon range

PG Selective Extended Electronic Trip Unit PremEon G

PremEon extended trip unit rating (amps)


Frames 250 400 600
PG600

PremEon G - Protections
Long Time (LT) Short Time (ST) Instantaneous (I) Neutral Protection Ground Fault (GF)
Current: AJ
Advanced Metering: EJ
PremEon G Trip Unit Subtypes
Current: AK , AL , AM

PremEon G
Advanced Metering: EK, EL, EM

Frame PremEon G - electronic trip unit overview


LT ST I Neutral Protection GF
Ir setting Im setting Ii setting Ig setting
pick-up band pick-up band pick-up band 4P 4P 4P pick-up band
In ± 7% Ir 10% Im ±10% Ii 4T 3.5T 3T ±10% Ig
(A) 100% 50% 0% (Off)
Applicable for breaker types
kA @ 415V min (A) max (A) min (A) max (A) Ii (A) min (A) max (A)
0.2-1 x In 1.5-12.5 x Ir 1-26 x In 0.2-1 x In

250
1A steps 0.1x steps 0.1x steps 0.01 steps
Intro
H - 100kA

P - 150kA

50 250 75 3125 6500 50 250


L - 150kA
N - 50kA
C - 25kA

E - 36kA

1.5-10 x Ir 1-17 x In
400 80 400 120 4000 6800 80 400

PG LTD
Clear
STD RELT(1) =Ir =Ir/2
Not
Protected
GFD A
Definite time Temp. setting Definite time
Shape Bands time(2) (s)
min (s) max (s) pick-up band min (s) max (s)
@ 7.2 x Ir
Thermal 1.1 - 13.3 1.1 - 13.2 0.025 0.442 ± 10% Ii 0.042 0.442
2
I T
I4T
0.9 - 13.9 0.9 - 13.9
F1 - F22 0.54 - 137
I2T ON
Bands
Ii (A)
0.1x steps
I2T or I4T ON
Bands
B
1 - 11 0.6-10.0 x In 1-3

PremEon G - available settings" C


Long Time Delay - Thermal @ 7.2x pickup
Band Name
0.9 1.2 1.4 1.7 1.9 2.1 2.4 2.6
Breaker clearing time
2.9 3.1 3.4 3.6 3.9 4.1 4.4 4.6 4.9 5.1 5.4 5.8 6.3 6.8 7.3 7.8 8.3 8.8 9.3 D
0.76 1.01 1.26 1.50 1.75 2.00 2.24 2.49 2.74 2.98 3.23 3.48 3.72 3.97 4.22 4.46 4.71 4.96 5.20 5.70 6.19 6.68 7.17 7.67 8.16 8.65 9.15
Long Time Delay - I2t @ 7.2x pickup
Band Name
0.7 0.8 0.9
Breaker clearing time
1 1.2 1.4 1.5 1.8 2 2.3 2.7 3.1 3.5 4 4.6 5 6 7 8 10 11 13
E
0.63 0.72 0.82 0.94 1.07 1.23 1.41 1.61 1.85 2.12 2.43 2.79 3.20 3.68 4.22 4.84 5.56 6.38 7.33 8.41 9.66 11.09
Long Time Delay - I4t @ 7.2x pickup
Band Name
1 2 3
Breaker clearing time
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
F
0.032 0.035 0.037 0.041 0.046 0.053 0.061 0.072 0.087 0.106 0.130 0.162 0.204 0.259 0.331 0.424 0.546 0.705 0.913 1.184 1.538 1.976
Short Time Delay
Curve Name
1 2 3
50 Hz - Half cycles
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
G
3 4 5 6 7 8 9 10 12 14 16 18 20 24 28 32 36 40 44
50 Hz - Delay
0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.12 0.14 0.16 0.18 0.2 0.24 0.28 0.32 0.36 0.4 0.44
60 Hz - Half cycles
3 4 5 6 7 8 9 10 11 12 13 14 16 18 19 22 24 26 30 33 36 40 42 45 50 53 X
60 Hz - Delay
0.025 0.033 0.042 0.050 0.058 0.067 0.075 0.083 0.092 0.100 0.108 0.117 0.133 0.150 0.158 0.183 0.200 0.217 0.250 0.275 0.300 0.333 0.350 0.375 0.417 0.442
Ground Fault Delay
Curve Name
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
50 Hz - Half cycles
5 6 7 8 9 10 12 14 16 18 20 24 28 32 36 40 44
50 Hz - Delay
0.05 0.06 0.07 0.08 0.09 0.1 0.12 0.14 0.16 0.18 0.2 0.24 0.28 0.32 0.36 0.4 0.44
60 Hz - Half cycles
5 6 7 8 9 10 11 12 13 14 16 18 19 22 24 26 30 33 36 40 42 45 50 53
60 Hz - Delay
0.042 0.050 0.058 0.067 0.075 0.083 0.092 0.100 0.108 0.117 0.133 0.150 0.158 0.183 0.200 0.217 0.250 0.275 0.300 0.333 0.350 0.375 0.417 0.442

(1) RELT (Reduced Energy Let-Through) Instantaneous is for temporary use to provide faster and more sensitive protection.
Requires accessory module and 24Vdc power.
(2) Times for I4T long time delay bands are given at 2,5X Ir instead of 6X.x
B.15
GuardEon
Time Current Curves

Applies to all frames UL


Breaker PE150/250 ETU PremEon G Breaker All frames ETU PremEon G Ground Fault

Breaker PE150/250 ETU PremEon G Breaker All frames ETU PremEon G Ground Fault

1,000.00 1,000.00
LT
0.3 – 1.0x In Adjustable
1A increments pickup

100.00 100.00

LTD I4t shape


Trip Units

10.00 10.00

STD
STD I2t On Adjustable
ST Off time delay
1.00 I2t Off 1.00

STD
2-13x Ir
Definite
Intro 0.10
time
0.10

Inst
1-13.5x In
Seconds (S)

Seconds (S)
A I2t shape #1

I2t shape #2
0.01 0.01
0.1 1.0 10.0 100.0 0.1 1.0 10.0
X sensor rating X sensor rating

Curves drawn here are not intended to demonstrate exact adjustment ranges, exact pickup times or exact clearing times. Only general shapes and
intersections. For exact values of adjustment ranges, minimum pickup (commit time) and maximum clear see applicable reference tables

B.16
GuardEon
Time Current Curves

Applies to all frames UL


Breaker PG600 ETU PremEon G Breaker PG600 ETU PremEon G Extended Instantaneous

Breaker PG600 ETU PremEon G Breaker PG600 ETU PremEon G Extended Instantaneous

1,000.00 1,000.00
LT
0.2 – 1.0x In
1A increments

100.00 100.00

LTD

PremEon G
10.00 10.00

STD
STD I2t On
ST Off
1.00 I2t Off 1.00

STD
1.5-12.5x Ir

0.10 0.10
Intro
Inst
1-13.5x In
Seconds (S)

Seconds (S)

A
0.01 0.01
0.1 1.0 10.0 100.0 0.1 1.0 10.0 100.0
X sensor rating X sensor rating

Curves drawn here are not intended to demonstrate exact adjustment ranges, exact pickup times or exact clearing times. Only general shapes and
intersections. For exact values of adjustment ranges, minimum pickup (commit time) and maximum clear see applicable reference tables

B.17
GuardEon
Electronic Trip Units

PremEon G

PremEon G protections can be expanded at will by the The same internal module fits in the E and G frames.
addition of separately available modules. Plug and play Once installed and connected to the trip unit, the
devices make upgrading to include advanced functions associated setup screens will activate on the trip unit.
and features easy. The external I/O module is capable of multiple advanced
functions with one device. It requires an Interconnect
Expansion modules are available in internal or external Module to connect to the breaker. All modules come with
versions. The small internal expansion modules offer the required connection cables for installation.
special functions like Reduced Energy Let-Through (RELT),
Zone Selective Interlocking (ZSI), or protective relays.
Trip Units

Reduced Energy Let-Through (RELT) Interconnect Module (ICM)


The RELT module allows the user to temporarily adjust the The ICM module provides the connection
instantaneous pick up (Ii) to a more sensitive setting. from the MCCB trip unit to the external I/O
The result is lower arc flash incident energy levels while module and/or communication module.
working on or near energized equipment.
• Not a stand alone device
• See protection tables for RELT settings
Intro • Enable via RELT switch, LCD or Modbus Description Cat. no.
• Requires 24VDC power supply ICM Module PICM
• Module includes 1 programmable output
A Description Cat. no.
RELT Module PRELT I/O Module (External)
RELT Switch Kit PRSK
The I/O module combines the capabilities of
B the three internal expansion modules into
single solution. It is equipped with connections
Zone Selective Interlocking Module (ZSI) for RELT, ZSI, and 3 programmable outputs.
The ZSI module offers the ability to implement a protection
C scheme with communicating circuit breakers. Installing this • Requires 24VDC power supply
module enables zone selective interlocking for • Includes required I/O harness
short time (Im), ground fault (Ig), and • Module includes 3 programmable outputs
D instantaneous (Ii) protections.
Description Cat. no.
• Requires 24VDC power supply I/O Module (ext) PIOMODE
• Module includes 1 programmable output
E
Description Cat. no.
ZSI Module PZSI

F
Protective Relay Module
The protective relay module provides two
G programmable outputs that can be mapped
to multiple protection alarms including: LT, ST,
INST, GF, Over Voltage, Under Voltage, Voltage
Unbalance, Current Unbalance and Power
X Reversal.

• Requires 24VDC power supply


• Module includes 2 programmable outputs
Description Cat. no.
Relay Module PPRLY

B.18
GuardEon
Time Current Curves

Applies to all frames UL

Breaker All frames ETU PremEon G Reduced Energy Let-Through ZSI curves and notes
1,000.00

Short time Allows user to set an additional unrestrained


ST-ZSI time delay and shape for in-zone protection.
Restraint signal received will toggle curve
between this setting and selective settings.
If user does not set unrestrained settings the
100.00 default in-zone protection will be at definite
time shape and minimum time delay.

Ground fault Allows user to set an additional unrestrained

PremEon G
10.00 Adjustable RELT GF-ZSI time delay and shape for in-zone GF
instantaneous
pickup.
protection.
See tables for Restraint signal received will arbitrate curve
clearing time & between this setting and the selective
adjustement settings.
range Default unrestrained settings are definite
1.00 time shape and minimum time band.

Threshold - Shifts restrained pickup setting of


ZSI (T-ZSI) associated protection to the right Intro
upon receipt of a blocking signal from
0.10
downstream trip unit. 16% for functions
with 7% tolerance, 23% for functions with
10% tolerance.
A
Seconds (S)

- Issues restraint signal a % below the


associated protection threshold to ensure
that the upstream protection does not trip
0.01 first due to tolerance overlap.
0.1
X sensor rating
1.0 10.0 100.0
B

Breaker All frames ETU PremEon G Short Time Zone Selective Interlocking Breaker All frames ETU PremEon G Short Time Threshold Zone Selective Interlocking
1,000.00 1,000.00 C
Short time threshold ZSI
Short time (ST) normal ZSI Fixed shift in “restrained” threshold
No change in pickup current when restraint signal is received.
Shift amount is automatic,
D
upon receipt of ZSI
restraint signal. no user setting required.

100.00 100.00

E
10.00 10.00
User set ST curve prior to
selecting ZSI, and restrained
F
curve when ST-ZSI selected.
User set CT curve prior to
selecting ZSI, and restrained

1.00
curve when ST-ZSI selected.

1.00
G

X
0.10 0.10
Seconds (S)

Seconds (S)

User set unrestrained in-zone User set unrestrained in-zone


ST protection settings; ST protection settings;
Default to minimum definite Defaults to minimum definite
time delay if not user set. time delay if not user set.

0.01 0.01
0.1 1.0 10.0 100.0 0.1 1.0 10.0 100.0
X sensor rating X sensor rating

Curves drawn here are not intended to demonstrate exact adjustment ranges, exact pickup times or exact clearing times. Only general shapes and
intersections. For exact values of adjustment ranges, minimum pickup (commit time) and maximum clear see applicable reference tables

B.19
GuardEon
Electronic Trip Units

PremEon G

Should the user need to upgrade to a trip unit with current PremEon G with advanced metering. Each trip unit is
or energy metering or add predictive maintenance features, equipped with an interchange interlock that prevents the
GuardEon makes that easy with plug and play trip units. inadvertent installation into a frame of a different size.
Thermal magnetic and PremEon S trip units can be
upgraded to PremEon G. PremEon G with advanced metering also offers distinct
predictive maintenance features including contact wear
PremEon G has impressive metering capability available and mechanism timing to help users identify issues and
in two options; PremEon G with current metering or avoid unplanned downtime.

Current Metering Maintenance


PremEon G with current metering offers monitoring of PremEon G gives a clear picture of the circuit breaker
Trip Units

current on the phase and neutrals(1) with class 1 accuracy(2). health using an LED status indicator, predictive
maintenance tools and detailed event diagnostics.
Advanced Metering
PremEon G with advanced metering offers current Contact Wear
metering as well as voltage metering via internal voltage The trip unit will automatically keep track of the circuit
sensors. Using the current and voltage values, it calclates breaker trip types and load conditions and calculate the
power, energy and demand with class 2 accuracy(2). Power expected percent of contact remaining based on that
quality (total harmonic distortion) has class 5 accuracy(2).
Intro information. An alarm can be set to alert the user when a
minimum threshold is met. The percent of contact
Alarms remaining and the alarm setting tool is accessible over
Alarms can be set for current and voltage unbalance as Modbus and/or using the free GE software;
A well as for power reversal. Over and under voltage pick up Trip Unit Toolkit.
and delays can be set but the breaker will simply trip if the
set levels are exceeded. Mechanism Timing
The time for the circuit breaker to open is measured and
B Trip Unit Toolkit recorded to the trip unit memory in the factory. The trip
The Trip Unit Toolkit is a free software package that unit will also measure the mechanism timing on each trip
enables users to manage, monitor, test and customize the event and keep a running log of the time to trip for the last
C parameters present in a range of GE trip units. Its powerful three trip events. Users can access mechanism timing info
and intuitive interface provides simple, easy access to over Modbus and/or using the free GE software; Trip Unit
manage functionality from startup and commissioning to Toolkit.
maintenance and testing directly on your personal
D computer. Diagnostics
(http://www.geindustrial.com/free) Event Data Capture
A total of ten trip events can be viewed in the events menu.
E An event code will be shown followed by event data and
the date and time.

The PremEon G has 18 trip codes that can be displayed. In


F GuardEon*
the event of a true trip, the icon that describes the event
Circuit Breakers will be turned on and the current, voltage, power or
with PremEon S and temperature value that caused the fault will be displayed
G Trip Units
on the powered up LCD screen along with the phase
G information if appliable.

Waveform Capture
X micro USB
PremEon G captures two full wave cycles before and after
an event. Current and voltage waveforms can be viewed
with the Trip Unit Toolkit as if you had captured them with
an oscilloscope. (http://www.geindustrial.com/free)

(1) Neutral accuracy not class 1. See metering table.


(2) Classes per IEC 61557-12

B.20
GuardEon
Metering claims

PremEon G
Type
Measurement Description Accuracy & Conditions(2)
Current Energy

Currents (A)
Phases I1, I2, I3 ± 1% Class 1 Current • •
0.2 - 1.2 x In • •
Maximum current of each phases Imax of I1, I2, I3 ± 1% • •
Neutral IN ± 2.5% 0.2 - 1.2 x In • •
Maximum neutral current Imax of IN ± 2.5% • •
Ground fault I1 + I2 + I3 + IN ± 10% • •
Average of phases(1) Iavg = ( I1 + I2 + I3)/3 ± 3% • •

Voltage (V)

PremEon G
Phase-to-phase or Phase-to-neutral V12, V23, V31 (L-L) ± 0.5% ± 20% of setpoint - •
(nominal), 120V -
690V
V1N, V2N, V3N (L-N) ± 0.5% - •
Average of phases(1) Vavg = (V1 + V2 + V3)/3 ± 1.5% - •

Frequncy (Hz)
Line frequency Hz ± 0.2 % - •

Power
Real power kW per phase, total ± 2% Class 2 (0.05 -1.2 x In) - • Intro
Reactive power kVAR per phase, total ± 2% 0.05 -1.2 x In - •
Apparent power kVA per phase, total ± 2% - •
Power factor % per phase, total ± 0.5% - •
A
Energy
Total energy kWh, total ± 2% Class 2 (0.05 -1.2 x In) - •
Total reactive energy kVARh, total ± 2% 0.05 -1.2 x In - •
Total apparent energy kVAh, total ± 2% - • B
Demand (Based on a specified time interval.
Adjustable from 5-60 minutes)
Active demand kW ± 2% 0.05 -1.2 x In - • C
Reactive demand kVAR ± 2% - •
Apparent demand KVA ± 2% - •

Power Quality D
Current Total Harmonic Distortion % per phase ± 5% Class 5 - •
Voltage Total Harmonic Distortion % per phase ± 5% - •

E
Related Protections
F
PremEon G
Type
G
Protections Description Accuracy & Conditions(2)
Current Energy

Related Protections
Current unbalance between phases % Iavg ± 3% 0.2 - 1.2 x In • • X
Voltage unbalance |ΔVavg - Vmin/max| ± 1.5% ± 20% of setpoint - •
> Vthreshold (nominal), 120V -
690V
Over voltage(3) %Vnominal ± 10% - •
Under voltage(3) %Vnominal ±10% - •
Power reversal kW threshold ± 10% 0.05 - 1.2 x In - •

(1) Available via the communication system only.


(2) Classes per IEC 61557-12. Accuracy is of the entire measurement system, including sensors. It is valid within the given ranges.
(3) Over/under voltage are recorded/communicated as part of a trip event only.

B.21
GuardEon
Electronic Trip Units

PremEon G

With PremEon G, communications can easily be added the communications module with a CAT5 type cable
with plug and play modules. Users can communicate set- (available in various lengths). It allows the daisy chaining
tings, metering data, status, maintenance info and more of up to 8 breakers for every 1 communication module.
via Modbus.
All the external communications modules are DIN rail
The interconnect module (ICM) is inserted into the acces- mounted for an easy and clean installation.
sory pocket and connected to a Y-connector with a cus-
tom ICM cable harness. The Y-connector is connected to

Communications Module Y Connector


One communication module provides The Y connector links the circuit
Trip Units

the hardware interface for Modbus breaker with the communications


485 for up to 8 circuit breakers with in module.
a distance of 100 feet.
• Includes required ICM harness
• Requires 24VDC power supply • Includes CAT5 cable (1m) to
• DIN-rail mounting connect to Y connector
• DIN rail mounting
Intro

A Description Cat. no. Description Cat. no.


CommunicationModule PCOMMOD Communication Module PYCONN

Extra CAT5 Cables


B 0.3m (1 ft)
1 m (3.3 ft)
PCAT50
PCAT51
3 m (9.8 ft)) PCAT53

C
Network of up to eight circuit breakers on a single external communications module
D
Customer
Modbus
E Network
24VDC
Breaker to Y Connector
PremEon Communications
External 24VDC
F Communication power
Modbus Communications

Module supply

G
Y Connector

GuardEon
Breaker
with
PremEon G
trip unit

Note: Internal communications module (PICM) required in each circuit breaker

B.22
GuardEon

PremEon G protection module combinations


RELT ZSI(1) Protective relays (2) RELT
Required accessories No advanced
Protective relays (1) Protective relays (1) ZSI(1)
protections
Protective relays (3)

ICM ICM ICM ICM ICM


Y-connector Y-connector Y-connector Y-connector Y-connector
Yes Communication module Communication module Communication module Communication module Communication module
Power Supply Power Supply Power Supply Power Supply Power Supply
I/O Module I/O Module I/O Module I/O Module
Communications

None RELT Module ZSI Module Protective Relay Mod. I/O Module
No RELT Switch Kit Power Supply Power Supply RELT Switch Kit

PremEon G
Power Supply Power Supply

(1) For ZSI communication with GE breakers other than GuardEon, a TIM1 module will be required

Power Supply USB Battery Pack


A power supply is needed to provide +24Vdc control power The PremEon G LCD display can
to GuardEon MCCBs with PremEon G trip units and the be powered on for setting,
expansion modules. For 240V and less, a compact power viewing, or commissioning using
supply is available. most commercially available
phone chargers with a microUSB
Intro
• Fuses are recommended (3A time-lag fuse on line inputs) connector. If you prefer to
• DIN-rail mounting purchase a USB battery pack
directly from GE, there is a A
Description Cat. no. portable USB battery pack kit
Power supply PPSAA available for purchase manufactured by I/O Magic,
model #I016B02PB).
B
Description Cat. no.
USB Battery pack PREMBP
C

Neutral Current Sensor


The neutral current sensor is required for ground fault D
protections and neutral protections on 3 phase/4 wire or 1
phase/3 wire (ground neutral service). It provides an input
signal to the breaker trip unit. Breakers connected to a
service without a neutral (3 phase/3 wire) do not require an
E
external connection
for ground fault to function properly.
F
Power supply plate • Includes GF harness cable
For applications above 240V, a power supply plate
assembly is available. The power supply plate includes fuse
protection for AC source input, a power transformer and a
Description Cat. no. G
E Frame
power supply. Supplemental +24Vdc input terminals are 25A sensor FEGS0025
provided for backup control power applications. 60A sensor FEGS0060

Description Cat. no.


125A sensor
150A sensor
FEGS0125
FEGS0150 X
250A sensor FEGS0250
120V Power supply plate SPSA120
208V Power supply plate SPSA208 G Frame
240V Power supply plate SPSA240 250A sensor PGGS0250
480V Power supply plate SPSA480 400A sensor PGGS0400
600V Power supply plate SPSA600 600A sensor PGSS0600

B.23
Smart, Reliable and Secure
GuardEon

Internal Accessories
C.2 Auxiliary contacts
C.3 Releases The circuit breaker Intro
External Accessories
C.4 Rotary handles Order codes A
C.7 Mounting & Connections
C.8 Terminations (other than standard) Trip units B
C.10 Terminal shields
Components and accessories C

Technical data D

Application guide E

Wiring diagrams F

Dimensions G

Numerical Index X

C.1
GuardEon
Internal accessories

Auxiliary contacts
Bell alarm mechanism
PE and PG Frames
Components and accessories

Available in three different versions, these contact blocks


indicate that the breaker has moved to its “tripped” position
Auxiliary contact blocks are fitted in an insulated auxiliary caused by a fault, the operation of the push to trip button
device compartment, easily accessible by removing the on the breaker front, or a shunt or undervoltage release
breaker cover. These contact blocks are interchangeable operation.
between all GuardEon frames and also compatible with
GE’s Record Plus* molded case circuit breakers. External
wiring can be brought into the accessory compartment
either through specifically designed break-out openings in
the breaker cover or through channels in the breaker rear.
Auxiliary contacts are designed to be field installable with
wire up to 2.5 mm2.

Open-closed indication Description Cat. no.


Available in five different versions, these contact blocks Bell alarm mechanism NO FABAM10
indicate the operating state of the circuit breaker (open/ Bell alarm mechanism NC FABAM01
Bell alarm mechanism changeover (CO) PABAM11
closed). Left mounted accessories are to be mounted only
on the left side of the toggle handle, right mounted on the
right. Bell alarm trip unit
Available in three different versions, these contact blocks
Intro indicate that the breaker has detected a fault condition
resulting in it moving to its “tripped” position. Fault tripping
is defined as an operation initiated by the trip unit protection
A device. By using a combination of bell alarm mechanism
and trip unit contacts it is possible to discriminate between
the kinds of opening operations.

B Bell alarm trip (NO)


Description Cat. no.
FABAT10
Description Cat. no.
Bell alarm trip (NC) FABAT01
Left mounted normally open (NO) FAS10L Bell alarm trip changeover (CO) PABAT11
Left mounted normally closed (NC) FAS01L
C Right mounted normally open (NO)
Right mounted normally closed (NC)
FAS10R
FAS01R
Universal mount changeover (CO) PAS11 Performance
The contacts offer a range of current and voltage ratings,
D including typical PLC operating levels (12V, 5mA, AC/DC) or
where a high thermal current rating is needed. The contacts
are self-cleansing and offer a life span equivalent to or
exceeding those of the breakers. The values in TABLE XX are
E in accordance with the EN 60947-5-1 standard.

C.2 * Indicates a trademark of the General Electric Company. All other trademarks are the property of their respective owners. © 2016 General Electric Company.
GuardEon

Releases
PE and PG Frames Undervoltage release
Available in nine different versions, these releases are
Shunt opening, shunt closing, and undervoltage releases designed to open the breaker contacts when a breaker is
are fitted in an insulated accessory compartment, easily in the “on” position and the undervoltage release is deac-
accessible by removing the breaker cover. These releases tivated. In de-energized state the device prevents the
are interchangeable between all GuardEon frames and also breaker contacts from moving and is suitable for use as a

Internal accessories
compatible with GE’s Record Plus molded case circuit lock-out coil. De-energization of the device or a drop in
breakers. External wiring can be brought into the accessory voltage to a value below the lower voltage limit will acti-
compartment either through specifically designed break- vate the device and initiate an opening operation.
out openings in the breaker cover or through channels in To prevent voltage dip driven nuisance tripping an under-
the breaker rear. Releases are designed to be field installa- voltage release with time delay is available. A kit that
ble with wire up to 2.5 mm2. includes an external DIN-rail mountable time delay unit
The devices are designed to trip the breaker when its con- with settable timing and undervoltage release is available
tacts are closed and the handle or position indication indi- for 230/240V AC control power.
cates the “on” position. When the breaker contacts are open
Voltage operation band (all types)
and the breaker handle or position indication indicates “off” deactivates between 0.35-0.7 Un
or “trip” activating the releases will have no effect. activates between 0.85-1.1 Un
Minimum reaction time  10 msec
Total intervention time (undelayed type)  ≤ 50 msec
Shunt opening release Delayed version (extra delay)  settable 100 to 250 msec
Available in seven different versions, these releases are
designed to trip the breaker remotely when in the “on” posi- Intro
tion.

Coil Burden
Voltage operational band
VA
0.7-1.1 Un
A
Minimum pulse duration 10 msec
10 msec ≤ 50 msec

Description Cat. no. C


Undervoltage release 12V AC/DC FAUVRB
Undervoltage release 24V AC/DC FAUVRD
Undervoltage release 48V AC/DC FAUVRF
Undervoltage release 60V AC/DC FAUVRH
Undervoltage release 110V AC/DC
Undervoltage release 220/240V AC/DC
FAUVRJ
FAUVRN
D
Undervoltage release 400/415V AC FAUVR8
Undervoltage release 440/480V AC FAUVRU
Time delay undervoltage release 220/240V AC/DC FAUVDN
Description Cat. no. E
Shunt opening release 12V AC/DC FASHTB
Shunt opening release 24V AC/DC FASHTD
Shunt opening release 48V AC/DC FASHTF
Shunt opening release 60V AC/DC
Shunt opening release 110V AC/DC
FASHTH
FASHTJ F
Shunt opening release 220/240V AC/DC FASHTN
Shunt opening release 400/415V AC FASHTU

G
Shunt release - Performance Undervoltage releases - Performance

Voltage rating
Current ­consumption
mA
Power consumption
mW/mVA
Voltage rating
Current ­consumption
mA
Power consumption
mW/mVA
X
inrush hold inrush hold inrush hold inrush hold

12V DC 200 200 2.4 2.4 24V AC/DC 50 50 1.2 1.2


24V AC/DC 150 150 3.6 3.6 48V AC/DC 20 20  0.96  0.96
48V AC/DC 60 60  2.88   2.88 110/130V AC/DC 15 15 1.8 1.8
110/130V AC/DC 40 40 4.8 4.8 220/240V AC 250V DC 15 15  3.45  3.45
220/240V AC 250V DC 20 20 4.6 4.6 400/440V AC 15 15 6.6 6.6
400/440V AC 15 15 6.6 6.6
480V AC 15 15 7.2 7.2

(1) Not applicable for FK Frame undervoltage release.

C.3
GuardEon
External accessories
Rotary handle
GuardEon rotary handles allow manual operation of the Through door rotary handle
Components and accessories

breakers from a 120 degree rotational input. Designed for installation to allow a breaker to be placed
The GuardEon rotary handle is specifically designed to behind a door or cover plate and have the rotary handle
allow the user to change the linear motion of the breaker to protrude through a door/cover. The rotary handle features
a rotation over a 120° angle. This can be accomplished by a door opening, or cover plate, removal prevention inter-
simply adding an adaption box to the breaker front. For all lock. This prevents door opening (or cover plate removal)
GuardEon breakers, 2 o’clock is the “Off” position and 6 when the breaker is in the on position. It also includes a
o’clock is the “On” position. The “Trip” is located between the mechanism that automatically trips the breaker if the door
“on” and “off” positions. or cover plate is not present (a bypass is available).
The handles are optionally available with two early closing/
Depending on configuration, each GuardEon rotary handle late opening contact blocks pre-installed to save installation
allows the use of up to three 5 to 8 mm padlocks or one time. The rotary handle is available in grey for normal appli-
keylock (integral to the handle itself) to lock the breaker in cations and in a yellow/red combination for machine tool
the “off” or “on” position. applications.

Three operator types are available: direct breaker mounted


(attached directly to the face of the breaker, enabling rotary Through door rotary handle
input), direct mounted with through-door access (includes Description Cat. no. Cat. no.
an accessory flange for finishing the panel door), and For frames: E G
Through door grey rotary handle P1NRC P2NRC
through door or panel mounting (allows mounting of the Through door yellow/red rotary handle P1NRCV P2NRCV
handle on a panel door while the breaker is mounted behind
Intro in the panel)
Through door grey rotary handle with
early close / late open contacts
P1NRY P2NRY

Through door yellow/red rotary handle P1NRYV P2NRYV


with early close/late open contacts
Special kits are available to satisfy NFPA 79 requirements
A for permanently connected operating handles that require
deliberate and tool free action to operate the breaker with
the door open. Panel door rotary handle
The panel door rotary handle is designed for use in applica-
B Direct mount rotary handle tions that require a handle and escutcheon mounted on the
Designed for installation directly on the front of the breaker, door or panel front with the breaker mounted to the panel
the direct mount rotary handle is available in grey for nor- back or interior chassis. Connection to the breaker is accom-
C mal applications and in a yellow/red combination for
machine tool applications.
plished via a shaft that goes into an adapter box directly
installed onto the breaker front. This design allows for a total
depth of up to 350 mm (from the back of the breaker to the
door front).
D An optional design has room for two early closing/ late open-
ing contact blocks that, in order to save installation time, are
delivered pre-mounted. The handle is available in grey for
normal applications and in a yellow/red combination for
E machine tool applications. Interlocks that prevent the opening
of the door while the breaker is on are standard.

F Panel door rotary handle


Description Cat. no. Cat. no.
Description Cat. no. Cat. no.
For frames: E G
For frames: E G
G Direct mount grey rotary handle
Direct mount yellow/red rotary handle
P1NRF
-
P2NRC
P1NRFV
Panel door grey rotary handle
Panel door yellow/red rotary handle
P1NRD
P1NRDV
P2NRD
P2NRDV
Panel door grey rotary handle with early P1NRZ P2NRZ
Direct mount grey rotary handle P2NRF P2NRY close/late open contacts
Direct mount yellow/red rotary handle P2NRFV P2NRYV
Panel door yellow/red rotary handle with P1NRZV P2NRZV
early close/late open contacts
X

C.4
GuardEon

Rotary handle accessories


Push to trip adapter – Allows the user to extend the push to GuardEon operators use a motor, springs, and coils to
trip function to the front of a door or cover when using a open and close the breaker. Local operation is also pos-
panel door rotary handle. sible via a charging handle and Push-to-Open and Push-
to-Close buttons. Locking is possible in the “off” posi-
tion via a push-to-release padlock feature which allows
Description Cat. no.

External accessories
up to three padlocks with shanks from 5-8mm.
Push to trip adapter – E Frame P1NFT
Push to trip adapter – G Frame P2NFT

Extension shaft – Allows the user to extend the shaft of a


panel door rotary handle up to 600mm.

Description Cat. no.


Extension shaft – E & G Frames PENRE
Electrical operators
Description Cat. no. Cat. no.
Side-by-side installation adapter kit – A set of covers that For frames: E G
bridge the gap between E Frame breakers with rotary han- Electrical operator 24V AC/DC P1EMFD P2EMFD
dles when mounted side-by-side inside a panel. Not for use Electrical operator 48V AC/D - P2EMFF
Electrical operator 48V to 110V AC/D P1EMFF -
with panel door rotary handles. Electrical operator 60V AC/DC
Electrical operator 110/120V AC/DC
-
-
P2EMFH
P2EMFJ Intro
Electrical operator 220/250V AC/DC P1EMFN P2EMFN
Description Cat. no. Electrical operator 400/440V AC P1EMF8 P2EMF8
Side-by-side installation adapter kit – E Frame PENR4
A
Draw-out adapter – Needed to install a rotary handle with
an E Frame draw-out breaker.
B
Description Cat. no.
Draw-out adapter – E Frame PENRW
C
NFPA 79 handle kit – Adapts a panel door rotary handle
to comply with NFPA 79’s requirements for permanently
connected operating handles with deliberate action D
needed to operate the breaker with the door open.

Description Cat. no. E


NFPA 79 rotary handle kit – E Frame P1NFP
NFPA 79 rotary handle kit – G Frame P2NFP

F
Large handle kit – Allows for a rotary handle that extends
beyond the front breaker escutcheon to lower the force
needed to operate the E Frame breaker.
G
Description Cat. no.
Large handle kit – E Frame P2LHK

X
Electrical operators
GuardEon breakers can be operated (open/close)
remotely using front mounted electrical operators.
Two operator sizes cover the entire GuardEon platform
making selection easy. Many voltage ratings and quick
field installation allow for simple and flexible application.

C.5
GuardEon

Breaker mechanism
Description Cat. no. Cat. no. Description Cat. no. Cat. no.
Components and accessories

For frames: E G For frames: E G


3 pole, 160A RCD 220/440V AC PEQDB3MJ - Breaker mechanism PENBM P2NBM
3 pole, 160A RCD 400/690V AC PEQDB3HJ -
4 pole, 160A RCD 22/440V AC PEQDB4MJ -
4 pole, 160A RCD 400/690V AC PEQDB4HJ -
3 pole, 250A RCD 220/440V AC
3 pole, 250A RCD 400/690V AC
PEQDB3MK
PEQDB3HK
-
-
Operating cables
4 pole, 250A RCD 220/440V AC PEQDB4MK - Description Cat. no. Cat. no.
4 pole, 250A RCD 400/690V AC PEQDB4HK -
3 pole RCD 220/440V AC - PGQDB3M For frames: E G
3 pole RCD 400/690V AC - PGQDB3H 0.91m (3’) operating cable SC3L SC3H
4 pole RCD 220/440V AC - PGQDB4M 1.22m (4’) operating cable SC4L SC4H
4 pole RCD 400/690V AC - PGQDB4H 1.52m (5’) operating cable SC5L SC5H
1.82m (6’) operating cable SC6L SC6H
2.13m (7’) operating cable SC7L SC7H
2.43m (8’) operating cable SC8L SC8H
Cable operators 2.74m (9’) operating cable
3.05m (10’) operating cable
SC9L
SC10L
SC9H
SC10H
GuardEon cable operators allow the operation of a breaker
inside an enclosure or cabinet via a flange mounted handle
on the outside of the enclosure or cabinet. The flexible Padlock device for toggle handle
cable provides a mechanical linkage between the handle GuardEon’s robust padlocking devices allow users to safely
and the breaker but allows maximum flexibility in mounting work on installations protected by GuardEon breakers. With
location and orientation. removable and permanently mounted options, these pad-
locking devices ensure complete and safe isolation of
Intro GuardEon cable operating mechanisms are suitable for downstream connected circuits from supplied power.
applications in a wide variety of enclosure types and sizes. Permanent padlocking devices offer a very secure stainless
Handles are available in either 152mm (6 inch) or 254mm steel solution that complies with EUSERC regulations.
(10 inch) lengths, and for IP10, 14, 52, and 66 (NEMA Type 1,
A 3R, 4, 4X, 12, or 13) enclosures.

The handle assembly is combined with one of eight operat-


B ing cables, with lengths from 0.91 to 3.05 meters (3 to 10
feet), to cover a broad range of breaker mounting locations
in the enclosure. The cable links the handle assembly to the
breaker mounted operating mechanism and transmits the
C mechanical force and motion of the handle mechanism to
the breaker mechanism.
Each breaker requires one handle assembly, one breaker Padlock
D mounted operating mechanism, and one cable. Description Cat. no. Cat. no.
For frames: E G and K
Removable padlock FD1PR P2PR
Fixed padlock – off position only PE1PE P21PE

E Fixed padlock – on or off position PE1PF P21PF

DIN-Rail mounting kit


F All GuardEon E Frame breakers can be installed on (symmetric)
35mm DIN profile (EN50022) by using an adapter.
The DIN-Rail adapter is mounted on the back of the breaker.

G
Handle mechanism
Description Cat. no.

X For frames:
152mm (6”) NEMA 1, 3R, 12, 13 handle mechanism – E
E
PNHM1
and G Frames
254mm (10”) NEMA 1, 3R, 12, 13 handle mechanism – E PNHM2
and G Frames
152mm (6”) NEMA 4, 4X handle PNHM3
mechanism – E and G Frames
254mm (10”) NEMA 4, 4X handle PNHM4
mechanism – E and G Frames

Description Cat. no.


3 pole DIN-Rail mounting kit PEKD3
4 pole DIN-Rail mounting kit PEKD4

C.6
GuardEon

Mounting & Connections


Plug-in
The GuardEon plug-in version allows for quick, safe, and easy
interchange of breakers. It is made up of a standard breaker
with fixed front connection, a set of plugs, a trip mechanism

Mounting & Connections


fitted to the breaker and a monoblock base into which the
breaker is plugged.

When the breaker is removed from the plug-in base it auto-


matically trips before the plug-in contacts in the base are

RCD Overview /
disconnected. The breaker can be operated (opened and
closed) when removed from the plug-in base. On attempted
insertion of a breaker in the “on”, or closed, position into the
Accessories
plug-in base, the GuardEon breaker trips before the plug-in
contacts in the base are connected. Description Cat. no.
8 pole auxiliary disconnect complete set FAPFM
8 pole auxiliary disconnect fixed part FAPF8
GuardEon plug-in kits are made up of two parts: mobile 8 pole auxiliary disconnect mobile part FAPM8
and fixed. The mobile part is fitted to the breaker and is 10 pole auxiliary disconnect complete set FAPPS
10 pole auxiliary disconnect complete set (gold plated for PAPPG
made up of a multi-pole set of plugs. The fixed part is a use with PremEon G trip unit advanced features)
monoblock base that can be mounted to a backplate or
connection utilizing the same standard connections as the
breaker. Either part can be ordered separately or together Draw-out
as a complete kit. A draw-out version allows quick and easy disconnection of Intro
the breaker while providing a positive indication of isolation.
Several optional accessories are available to allow the use of The draw-out kit iws made up of a set of plugs and a trip
internal accessories in a plug-in configuration. Wiring can be mechanism that are fitted to a breaker, a monoblock base A
connected through plug and socket combinations. When into which the breaker is plugged, and a metal support cradle.
wiring PremEon G accessories such as communications or
advanced protection feature accessories, high-fidelity gold Connections to the breaker and internal accessories are
plated 10 pole auxiliary disconnects are needed. made through plug and socket connection that is automati- B
cally connected and disconnected during draw-out operation.

Connections to the overcurrent protective trip device (for


communications, RELT, ZSI and protective relays) are accom-
C
plished through an umbilical with a male/female 10-pin
auxiliary disconnect that is manually connected/discon-
nected. This feature allows connection to the trip device in D
any racking position.

The cradle allows for placing the breaker in one of three positions.
• Connected: Main and auxiliary contacts are fully E
Plug-in kits connected to the base.
Description Cat. no. Cat. no. • Test/disconnected: Main contacts are disconnected.
For frames:
3 pole complete plug-in device
E
FEDDF3
G
FGDDF3
Auxiliaries are connected. This allows for a complete test of
the secondary wiring/functionality without having the
F
4 pole complete plug-in device FEDDF4 FGDDF4
3 pole fixed part FEDFF3 FGFF3 mains connected.
4 pole fixed part FEDFF4 FGFF4 • Remove: Main and auxiliary contacts are fully discon-
3 pole mobile part
4 pole mobile part
FEDMP3
FEDMP4
FGDMP3
FGDMP4 nected from the metal support cradle and the plug-in G
base, the breaker can be removed.

C.7
GuardEon

Terminations (other than standard)


Draw-out kits
Components and accessories

Description Cat. no. Cat. no.


For frames: E G
3 pole PEWB3 PGWB3
4 pole PEWB4 PGWB4

Flat extenders
Through door kits Description Cat. no. Cat. no.
Description Cat. no. Cat. no. For frames: E G
3 pole flat extensions FEBES3 -
For frames: E G 4 pole flat extensions FEBES4 -
Through door kit (toggle operator) PEWT PGWT 3 pole flat extenders - FEBES3
Through door kit (motor operator) PEWM PGWM 4 pole flat extenders - FEBES4
Through door kit (rotary handle) PEWN PGWN

Secondary disconnect assemblies


Description Cat. no. Cat. no.
For frames: E G
16 poles FEWA2 FGWA2
24 poles - FGWA3
32 poles - -
Heightened extenders
Description Cat. no. Cat. no.
Position indication
Intro Description Cat. no.
For frames:
3 pole heightened extenders
E
FEBEH3
G
FGBEH3
4 pole heightened extenders FEBEH4 FGBEH4
For frames: E
Set of 3 normally open (NO) contacts FAS30W
A Set of 3 normally open (NO) and
3 normally closed (NC) contacts
FAS33W
Set of 3 change over contacts (CO) PAS33W

B Insertion prevention kits


Description Cat. no. Cat. no.
For frames: E G 90° twisted extenders
Insertion prevention kit FAPIP FAPIP
C Description Cat. no. Cat. no.
For frames: E G
3 pole 90° twisted extenders FEBEA3 FGBEA3
4 pole 90° twisted extenders FEBEA4 FGBEA4

F 45° bend angle


Description Cat. no.
For frames: E
3 pole 45° bend angle FEBE43
G 4 pole 45° bend angle FEBE44

90° bend angle


Description Cat. no.
For frames: E
3 pole 90° bend angle FEBE93
4 pole 90° bend angle FEBE94

C.8
GuardEon

Distribution lugs
Description Cat. no.
For frames: E
3 pole distribution lugs FETCA630A
4 pole distribution lugs FETCA640A
Flat spreaders
Description Cat. no. Cat. no. Control wire terminals
For frames: E G
3 pole flat spreaders FEBSS3 FGBSS3 Description Cat. no. Cat. no.
4 pole flat spreaders FEBSS4 FGBSS4 For frames: E G
3 pole 20 to 150A PCALK315LV -
4 pole 20 to 150A PCALK415LV -
3 pole 150 to 250A PCALK316LV -

Terminations
4 pole 150 to 250A PCALK416LV -
2 pole 600A - PCALK217LV
3 pole 600A - PCALK317LV
4 pole 600A - PCALK417LV

Rear connections External box clamps


Description Cat. no. Cat. no. Description Cat. no.
For frames: E G For frames: E
3 pole (short, long, short) FEBRC3 FGBRC3 3 pole 70 to 185mm2 FETCA1323
rear connections 4 pole 70 to 185mm2 FETCA1423
4 pole (short, long, short, long) FEBRC4 FGBRC4
rear connections
3 pole (short, short, short) FEBRCS3 FGBRCS3
Intro
rear connections
4 pole (short, short, short, short) FEBRCS4 FGBRCS4
rear connections
A
Lugs
E Frame
Cat. no. Poles Amperage Conductor Conductor
B
size material
PCALK315 3 25 to 150A 2.08-13.3mm2 Al/Cu
2.08-13.3mm2
PCALK415
PCALK316
4
3
25 to 150A
150 to 250A 21.1-85mm2
Al/Cu
Al/Cu C
PCALK416 4 150 to 250A 21.1-85mm2 Al/Cu
PCCUK318 3 25 to 150A 2.08-13.3mm2 Cu
PCCUK418 4 25 to 150A 2.08-13.3mm2 Cu
21.1-85mm2
PCCUK329
PCCUK429
3
4
150 to 250A
150 to 250A 21.1-85mm2
Cu
Cu D

G Frame F
Cat. no. Poles A Conductor Conductor
size material
PGTCA1227
PGTCA1327
2
3
400
400
1x240mm2 or 2x95mm2
1x240mm2 or 2x95mm2
Al/Cu
Al/Cu G
PGTCA1427 4 400 1x240mm2 or 2x95mm2 Al/Cu
PGTCA220B 2 600 Top 16-250mm2 Al, Al/Cu
10-200mm2 Cu/
bottom 35-250mm2 Al/Cu
PGTCA320B 3 600 Top 16-250mm2 Al, Al/Cu X
10-200mm2 Cu/
bottom 35-250mm2 Al/Cu
PGTCA420B 4 600 Top 16-250mm2 Al, Al/Cu
10-200mm2 Cu/
bottom 35-250mm2 Al/Cu
PGTCA320B 2 600 2x180-380mm2 Al/Cu
PGTCA330B 3 600 2x180-380mm2 Al/Cu
PGTCA340B 4 600 2x180-380mm2 Al/Cu
PGTCC320B 2 600 2x180-380mm2 Cu
PGTCC330B 3 600 2x180-380mm2 Cu
PGTCC340B 4 600 2x180-380mm2 Cu

C.9
GuardEon

Terminal shields
Components and accessories

Short terminal shields Long and widened


Description Cat. no. Cat. no. Description Cat. no.

For frames: E G For frames: G


3 pole PEJS3 PGJS3 3 pole PGJW3
4 pole PEJS4 PGJS4 4 pole PGJW4

Intro
Medium terminal shields Phase separators
Description Cat. no.
Description Cat. no. Cat. no.
A For frames:
3 pole
G
PGJM3 For frames:
Set of 12 FEJP
E G
FGJP
4 pole PGJM4

D Long terminal shields Back plates


Description Cat. no. Cat. no. Description Cat. no. Cat. no.
For frames: E G For frames: E G
E 3 pole
4 pole
PEJL3
PEJL4
PGJL3
PGJL4
Back plates PEJB PGJB

C.10
GuardEon

The circuit breaker Intro


D.2 Ratings table
D.6 Power dissipation Order codes A
D.9 Clearances (minimum safety distances)
D.10 Derating at temperatures other than 40°C Trip units B
D.12 Current limitation
D.14 Environmental considerations Components and accessories C
D.16 Use in DC networks
Technical data D

Application guide E

Wiring diagrams F

Dimensions G

Numerical Index X

D.1
GuardEon
UL489
Circuit breaker type PE150
Interruption tier B C E N H L
Poles Number of 2(1), 3, 4
Maximum voltage rating Volts AC 600
Volts DC 500
Interrupting Ratings - rms symmetrical 240V AC 35 42 65 100 150 200
amperes (kA) 480V AC 18 25 35 65 100 150
600V AC 14 18 25 35 42 65
250V DC two pole 25 50 85 100
500V DC three pole 25 50 85 100
Trip Units Interchangeable Yes
Thermal magnetic line LTM
Thermal magnetic generator GTM
Thermal magnetic discriminating LTMD
Magnetic only Mag Break or PremEon S
Electronic standard PremEon S
Electronic enhanced PremEon G

EN 60947-2
Technical data

Circuit breaker type PE150


Denomination B C E N H L
Poles Number of 2(1), 3, 4
Rated Insulation Voltage (Ui) Volts 750
Rated Impulse withstand voltage (Uimp) Kilovolts 8
Rated operational voltage Ue Volts AC 690
Volts DC 500
Category of use A A A A A A
Suitable for use as a isolator Yes Yes Yes Yes Yes Yes
Rated current Ith=Ie A at 40C 160
Ultimate breaking capacity Icu (kA) 230/240V AC 36 42 65 100 150 200
400/415V AC 18 25 36 50 100 150
440V AC 18 25 36 50 100 150
500V AC 14 18 30 42 50 100
690V AC 10 12 22 25 30 50
Intro 250V DC two pole
500V DC three pole
-
-
-
-
25
25
50
50
85
85
100
100
Service breaking capacity Ics (kA) 230/240V AC 36 42 65 100 150 200
400/415V AC 18 25 36 50 100 130
440V AC 18 25 36 50 100 130
A 500V AC
690V AC
14
10
18
12
30
17
42
19
50
20
100
20
250V DC two pole - - 25 50 85 100
500V DC three pole - - 25 50 85 100
Making capacity Icm (kA peak) 400/415V AC 36 53 76 105 220 330

B Single phase breaking capacity IIT (kA)


500V AC
230V AC
28
18
36
25
63
36
88
50
105
100
220
150
400/415V AC 10 12 22 25 30 38
Endurance (CO operations) Mechanical 25000
Electrical at In and 415V AC 10000
Electrical at In/2 and 415V AC 20000
C Endurance (On-tripped operations)
Trip Units
Mechanical
Interchangeable
10000
Yes
Thermal magnetic line LTM
Thermal magnetic generator GTM
Magnetic only Mag Break or PremEon S
D Electronic standard
Electronic enhanced
PremEon S
PremEon G

EN 60947-3
E Non Automatic Circuit Breaker/Switch Type
Denomination
PE150
Y
Rated current In (class AC23) 220V AC to 690V AC 150
Rated making capacity Icm (kA peak) 4,2
Short-term withstand current Icw (A) Icw eff.1 second 3
Icw eff. 3 seconds 3
F
EN 60947-4
Use in motor circuits
Rated current Ith A at 65° C 150
G Endurance (CO operations) Mechanical
Electrical at In class AC23 @415VAC
25000
10000
Operations per hour 120
Protection Short circuit only (separate overload device) Mag-Break/PremEon S & PremEon G
Overload class 10 and short circuit PremEon S & PremEon G

X Max In (A) class 10


Max In (A) class 30
150
150
Earth fault unit (differential)

Installation
Mounting DIN-Rail Yes
Fixed Yes
Plug-in Yes
Draw-out Yes
Connection Front Yes
Rear Yes
Poles Number of 2(1) 3 4
Dimensions (mm) w Fixed front connection 105 105 140
h 170 170 170
d 95 95 95

(1) Three pole footprint (4) - Only 8kv with PremEon G (Voltage sensing) & PremEon S
(2) Toggle mechanism (5) - Limited to 500A only
D.2 (3) Stored energy mechanism (6) - Please contact GE
GuardEon
UL489
Circuit breaker type PE250
Interruption tier B C E N H L
Poles Number of 2(1), 3, 4
Maximum voltage rating Volts AC 600
Volts DC 500
Interrupting Ratings - rms symmetrical 240V AC 35 42 65 100 150 200
amperes (kA) 480V AC 18 25 35 65 100 150
600V AC 14 18 25 35 42 65
250V DC two pole 25 50 85 100
500V DC three pole 25 50 85 100
Trip Units Interchangeable Yes
Thermal magnetic line LTM
Thermal magnetic generator GTM
Thermal magnetic discriminating LTMD
Magnetic only Mag Break or PremEon S
Electronic standard PremEon S
Electronic enhanced PremEon G

EN 60947-2

Ratings table
Circuit breaker type PE250
Denomination B C E N H L
Poles Number of 2(1), 3, 4
Rated Insulation Voltage (Ui) Volts 750
Rated Impulse withstand voltage (Uimp) Kilovolts 8
Rated operational voltage Ue Volts AC 690
Volts DC 500
Category of use A A A A A A
Suitable for use as a isolator Yes Yes Yes Yes Yes Yes
Rated current Ith=Ie A at 40C 250
Ultimate breaking capacity Icu (kA) 230/240V AC 36 42 65 100 150 200
400/415V AC 18 25 36 50 100 150
440V AC 18 25 36 50 100 150
500V AC 14 18 30 42 50 100
690V AC 10 12 22 25 30 50
250V DC two pole
500V DC three pole
-
-
-
-
25
25
50
50
85
85
100
100
Intro
Service breaking capacity Ics (kA) 230/240V AC 36 42 65 100 150 200
400/415V AC 18 25 36 50 100 130
440V AC 18 25 36 50 100 130
500V AC
690V AC
14
10
18
12
30
17
42
19
50
20
100
20 A
250V DC two pole - - 25 50 85 100
500V DC three pole - - 25 50 85 100
Making capacity Icm (kA peak) 400/415V AC 36 53 76 105 220 330

Single phase breaking capacity IIT (kA)


500V AC
230V AC
28
18
36
25
63
36
88
50
105
100
220
150 B
400/415V AC 10 12 22 15 25 38
Endurance (CO operations) Mechanical 25000
Electrical at In and 415V AC 10000
Electrical at In/2 and 415V AC 20000
Endurance (On-tripped operations)
Trip Units
Mechanical
Interchangeable
10000
Yes
C
Thermal magnetic line LTM
Thermal magnetic generator GTM
Magnetic only Mag Break or PremEon S
Electronic standard
Electronic enhanced
PremEon S
PremEon G
D
EN 60947-3
Non Automatic Circuit Breaker/Switch Type
Denomination
PE250
Y E
Rated current In (class AC23) 220V AC to 690V AC 250
Rated making capacity Icm (kA peak) 5,7
Short-term withstand current Icw (A) Icw eff.1 second 4
Icw eff. 3 seconds 4
F
EN 60947-4
Use in motor circuits
Rated current Ith A at 65° C 230
Endurance (CO operations) Mechanical
Electrical at In class AC23 @415VAC
25000
10000
G
Operations per hour 120
Protection Short circuit only (separate overload device) PremEon S & PremEon G
Overload class 10 and short circuit PremEon S & PremEon G
Max In (A) class 10
Max In (A) class 30
225
225 X
Earth fault unit (differential)

Installation
Mounting DIN-Rail Yes
Fixed Yes
Plug-in Yes
Draw-out Yes
Connection Front Yes
Rear Yes
Poles Number of 2(1) 3 4
Dimensions (mm) w Fixed front connection 105 105 140
h 170 170 170
d 95 95 95

D.3
GuardEon
UL489
Circuit breaker type PG600
Interruption tier C E N H L P
Poles Number of 2(1), 3, 4
Maximum voltage rating Volts AC 600
Volts DC -
Interrupting Ratings - rms symmetrical 240V AC 42 65 100 150 200 200
amperes (kA) 480V AC 25 35 65 100 150 600
600V AC 18 22 25 35 42 65
250V DC two pole -
500V DC three pole -
Trip Units Interchangeable
Thermal magnetic line -
Thermal magnetic generator -
Thermal magnetic discriminating -
Magnetic only PremEon S
Electronic standard PremEon S
Electronic enhanced PremEon G

EN 60947-2
Technical data

Circuit breaker type PG600


Denomination C E N H L P
Poles Number of 2(1), 3, 4
Rated Insulation Voltage (Ui) Volts 750
Rated Impulse withstand voltage (Uimp) Kilovolts 8
Rated operational voltage Ue Volts AC 690
Volts DC
Category of use B(5) B(5) B(5) B(5) B(5) B(5)
Suitable for use as a isolator Yes Yes Yes Yes Yes Yes
Rated current Ith=Ie A at 40C
Ultimate breaking capacity Icu (kA) 230/240V AC 42 65 100 150 200 200
400/415V AC 25 36 50 100 150 150
440V AC 25 36 50 100 130 130
500V AC 18 30 42 50 100 100
690V AC 12 22 25 30 40 40
Intro 250V DC two pole
500V DC three pole
Service breaking capacity Ics (kA) 230/240V AC 42 65 100 150 200 200
400/415V AC 25 36 50 100 150 150
440V AC 25 36 50 100 130 130
A 500V AC
690V AC
18
10
30
10
42
10
50
10
100
10
100
10
250V DC two pole
500V DC three pole
Making capacity Icm (kA peak) 400/415V AC 53 76 105 220 330 330

B Single phase breaking capacity IIT (kA)


500V AC
230V AC
36
25
63
36
88
50
105
50
220
50
220
50
400/415V AC 10 10 10 10 10 10
Endurance (CO operations) Mechanical 20000
Electrical at In and 415V AC 5000
Electrical at In/2 and 415V AC 10000
C Endurance (On-tripped operations)
Trip Units
Mechanical
Interchangeable
8000
Yes
Thermal magnetic line -
Thermal magnetic generator -
Magnetic only PremEon S
D Electronic standard
Electronic enhanced
PremEon S
PremEon G

EN 60947-3
E Non Automatic Circuit Breaker/Switch Type
Denomination
PG600
Y
Rated current In (class AC23) 220V AC to 690V AC 600
Rated making capacity Icm (kA peak) 9,2
Short-term withstand current Icw (A) Icw eff.1 second 6,5
Icw eff. 3 seconds 5,0
F
EN 60947-4
Use in motor circuits
Rated current Ith A at 65° C 500
G Endurance (CO operations) Mechanical
Electrical at In class AC23 @415VAC
20000
5000
Operations per hour 60
Protection Short circuit only (separate overload device) PremEon S & PremEon G
Overload class 10 and short circuit PremEon S & PremEon G

X Max In (A) class 10


Max In (A) class 30
500
500
Earth fault unit (differential) -

Installation
Mounting DIN-Rail No
Fixed Yes
Plug-in Yes
Draw-out Yes
Connection Front Yes
Rear Yes
Poles Number of 2(1) 3 4 4
Dimensions (mm) w
 Fixed front connection 140 140 185 185
h 265 265 265 265
d 115 115 115 115

(1) Three pole footprint (4) - Only 8kv with PremEon G (Voltage sensing) & PremEon S
(2) Toggle mechanism (5) - Limited to 500A only
D.4 (3) Stored energy mechanism (6) - Please contact GE
GuardEon

Smart, Reliable and Secure

D.5
GuardEon
Power dissipation

Standards
The standard for low voltage equipment is defined in
the EN 61439-1, the EN 50298 and the IEC 60890. These
provide a theoretical method to ­calculate the tempera-
ture rise within an enclosure. The main ­element in these
calculations is the power ­dissipation of the equipment
installed. By totalizing this value for all the installed
devices, connections, cables and ­busbars it is possible
to calculate the temperature rise within the enclosure.
Here, for ­normal applications a temperature rise within
Technical data

the enclosure of 50 Kelvin is assumed.


The absolute value of this temperature may not exceed
70°C (the sum of the ambient temperature in Celsius
and the temperature rise in Kelvin).

Use
An enclosure manufacturer can provide the exact data
on the allowable power dissipation within a certain
enclosure. The values depend on the ­enclosure type,
the ventilation it offers and on where the components
Intro are located within this enclosure. The table indicates
the temperature rise within a certain ­enclosure dimen-
sion. This at the top and middle of the enclosure in function
of the installed heat dissipation (products) in Watt.
A

B
Heat dissipation tables: enclosure 36 modules
C
According IEC 60890, temperature rise in Kelvin
Rear against wall - external dimensions
D 900x876x250 1050x876x250 1200x876x250 1350x876x250 1500x876x250 1650x876x250
Watt 36 Mod/5Row 36 Mod/6Row 36 Mod/7Row 36 Mod/8Row 36 Mod/9Row 36 Mod/10Row
Half Top Half Top Half Top Half Top Half Top Half Top
10 3 4 2 3 2 3 2 3 2 3 2 2

E 20
30
40
5
7
8
7
9
12
4
6
7
6
8
11
4
5
6
5
7
9
3
4
6
5
7
8
3
4
5
5
6
8
3
4
5
4
6
7
50 10 14 9 13 8 11 7 10 6 9 6 9
60 12 16 10 15 9 13 8 12 7 11 6 10
70 13 18 12 17 10 15 9 13 8 12 7 11
80
F
15 20 13 18 11 16 10 15 9 14 8 13
90 16 22 14 20 12 18 11 16 10 15 9 14
100 18 24 15 22 13 20 12 17 11 16 10 15
120 20 28 18 26 15 23 13 20 12 19 11 18
140 23 32 20 29 17 26 15 23 14 22 13 20
160 26 36 22 32 19 29 17 25 16 24 14 22
180 28 39 25 35 21 31 18 28 17 26 16 24
G 200
220
31
33
43
46
27
29
39
42
23
25
34
37
20
22
30
33
19
20
29
31
17
18
27
29
240 35 49 31 45 27 40 23 35 22 33 20 31
260 38 53 33 48 29 42 25 38 23 36 21 33
280 40 56 35 51 30 45 26 40 24 38 22 35
300 42 59 37 53 32 47 28 42 26 40 24 37
X 320
340
45
47
62
65
39
41
56
59
34
35
50
52
29
31
44
47
27
29
42
44
25
26
39
41
360 49 68 43 62 37 55 32 49 30 46 27 43
380 51 71 45 65 39 57 34 51 31 48 28 45
400 - - 47 67 40 60 35 53 33 50 30 47
420 - - 49 70 42 62 37 55 34 52 31 48
440 - - - - 44 64 38 57 35 54 32 50
460 - - - - 45 67 39 59 36 56 33 52
480 - - - - 47 69 41 61 38 58 34 54
500 - - - - 48 71 42 64 39 60 36 56
520 - - - - - - 43 66 40 62 37 57
540 - - - - - - 45 68 41 64 38 59
560 - - - - - - 46 70 43 66 39 61
580 - - - - - - - - 44 68 40 63
600 - - - - - - - - 45 70 41 64
650 - - - - - - - - - - 44 69
700 - - - - - - - - - - 47 73
750 - - - - - - - - - - - -

D.6
GuardEon
GuardEon power dissipation

The power dissipation tables included here indicate the The tables indicate the Watt loss per pole based on the
DC resistance of the GuardEon breakers in cold maximum current load of the breaker. To calculate the
­condition.The power dissipation per pole can be total Watt loss for a three or four pole breaker these
­calculated with this value and the average current ­values are multiplied by three.(1)
­flowing within the circuit (formula I2R).

(1) for circuits with a high 3rd harmonic content, please contact us

Power Dissipation - PE150 Frame

Power dissipation
Thermal magn. type (GTM) Switch (Y)
In (A) 25 30 40 50 60 80 100 125 150 150

Fixed version R in mΩ per pole 6.30 2.80 2.80 2.10 1.45 1.20 0.81 0.77 0.63 0.40
Dissipation Watt single pole 3.94 2.87 4.48 5.25 5.76 7.68 8.10 12.03 16.00 10.24
Dissipation Watt three poles 11.81 8.60 13.44 15.75 17.27 23.04 24.30 36.09 48.00 30.72
Plug-in version R in mΩ per pole 6.37 2.87 2.87 2.17 1.52 1.27 0.88 0.84 0.70 0.47
Dissipation Watt single pole 3.98 2.94 4.59 5.43 6.03 8.13 8.80 13.13 17.79 12.03
Dissipation Watt three poles 11.94 8.82 13.78 16.28 18.10 24.38 26.40 39.38 53.38 36.10
Fixed version R in mΩ per pole 6.38 2.88 2.88 2.18 1.53 1.28 0.89 0.85 0.71 0.48
with RCD Dissipation Watt single pole 3.99 2.95 4.61 5.45 6.07 8.19 8.90 13.28 18.05 12.29
Dissipation Watt three poles 11.96 8.85 13.82 16.35 18.22 24.58 26.70 39.84 54.14 36.86
Plug-in version R in mΩ per pole 6.45 2.95 2.95 2.25 1.60 1.35 0.96 0.92 0.78 0.55
with RCD Dissipation Watt single pole 4.03 3.02 4.72 5.63 6.35 8.64 9.60 14.38 19.84 14.08
Dissipation Watt three poles 12.09 9.06 14.16 16.88 19.05 25.92 28.80 43.13 59.52 42.24
PE150 Frame electronic type (PremEon S)
In (A) 25 60 125 150 Intro
Fixed version R in mΩ per pole 0.40 0.40 0.40 0.40
Dissipation Watt single pole 0.25 0.25 1.59 6.25
Dissipation Watt three poles 0.75 0.75 4.76 18.75
Plug-in version R in mΩ per pole
Dissipation Watt single pole
0.47
0.29
0.47
0.29
0.47
1.87
0.47
7.34
A
Dissipation Watt three poles 0.88 0.88 5.60 22.03
Fixed version R in mΩ per pole 0.48 0.48 0.48 0.48
with RCD Dissipation Watt single pole 0.30 0.30 1.91 7.50
Dissipation Watt three poles
Plug-in version R in mΩ per pole
0.90
0.55
0.90
0.55
5.72
0.55
22.50
0.55
B
with RCD Dissipation Watt single pole 0.34 0.34 2.18 8.59
Dissipation Watt three poles 1.03 1.03 6.55 25.78

D.7
GuardEon
Power Dissipation - PE250 Frame
Thermal magn. type (GTM) Switch (Y)
In (A) 125 150 200 250 250

Fixed version R in mΩ per pole 0.67 0.53 0.40 0.33 0.30


Dissipation Watt single pole 10.47 13.57 16.00 20.63 18.75
Dissipation Watt three poles 31.41 40.70 48.00 61.88 56.25
Plug-in version R in mΩ per pole 0.73 0.59 0.46 0.39 0.36
Dissipation Watt single pole 11.41 15.10 18.40 24.38 22.50
Dissipation Watt three poles 34.22 45.31 55.20 73.13 67.50
Fixed version R in mΩ per pole 0.74 0.60 0.47 0.40 0.37
with RCD Dissipation Watt single pole 11.56 15.36 18.80 25.00 23.13
Dissipation Watt three poles 34.69 46.08 56.40 75.00 69.38
Plug-in version R in mΩ per pole 0.80 0.66 0.53 0.46 0.43
with RCD Dissipation Watt single pole 12.50 16.90 21.20 28.75 26.88
Dissipation Watt three poles 37.50 50.69 63.60 86.25 80.63
PE250 Frame electronic type (PremEon S)
Technical data

In (A) 125 150 250

Fixed version R in mΩ per pole 0.30 0.30 0.30


Dissipation Watt single pole 4.69 7.68 18.75
Dissipation Watt three poles 14.06 23.04 56.25
Plug-in version R in mΩ per pole 0.36 0.36 0.36
Dissipation Watt single pole 5.63 9.22 22.50
Dissipation Watt three poles 16.88 27.65 67.50
Fixed version R in mΩ per pole 0.37 0.37 0.37
with RCD Dissipation Watt single pole 5.78 9.47 23.13
Dissipation Watt three poles 17.34 28.42 69.38
Plug-in version R in mΩ per pole 0.43 0.43 0.43
with RCD Dissipation Watt single pole 6.72 11.01 26.88
Dissipation Watt three poles 20.16 33.02 80.63

Intro
Power Dissipation - PG600 Frame
PG600 electronic type (PremEon S & G) Mag Break (MO) Switch (Y)
A In (A) 250 400 500 600 400 500 400 600

Fixed version R in mΩ per pole 0.11 0.11 0.10 0.10 0.11 0.10 0.11 0.10
Dissipation Watt single pole 6.88 17.60 25.00 39.69 17.60 23.75 17.60 39.69
Dissipation Watt three poles 20.63 52.80 75.00 119.07 52.80 71.25 52.80 119.07
B Plug-in/Draw- R in mΩ per pole
out version Dissipation Watt single pole
0.13
8.13
0.13
20.80
0.12
30.00
0.12
47.63
0.13
20.80
0.12
30.00
0.13
20.80
0.12
47.63
Dissipation Watt three poles 24.38 62.40 90.00 142.88 62.40 90.00 62.40 142.88
Fixed version R in mΩ per pole 0.16 0.16 0.15 0.15 0.16 0.15 0.16 0.15
with RCD Dissipation Watt single pole 10.00 25.60 37.50 59.54 25.60 37.50 25.60 59.54
C Dissipation Watt three poles
Plug-in/Draw- R in mΩ per pole
30.00
0.17
76.80
0.17
112.50
0.17
178.61
0.17
76.80
0.17
112.50
0.17
76.80
0.17
178.61
0.17
out version Dissipation Watt single pole 10.31 26.40 41.25 65.49 26.40 41.25 26.40 65.49
with RCD Dissipation Watt three poles 30.94 79.20 123.75 196.47 79.20 123.75 79.20 196.47

D.8
GuardEon
Clearances

Minimum distances

Power Dissipation / Clearances


A modern circuit breaker is designed to interrupt high The GuardEon circuit breaker has been designed to limit
short-circuit currents in a very limited time frame. the venting phenomanae to a minimum. However, it is
In doing so the breaker vents gas and and a limited necessary to take the following minimum distances into
amount of conductive fragments. account:

Minimum Distance Minimum Distance


between two side to a front panel from
by side mounted a GuardEon
GuardEon Breakers
Breakers = 0 mm = 0 mm
Protection degree
on breaker front
= IP40

Intro

Minimum Distances E
Distances in mm
Type a b c d

F
PE150 and PE250 To painted metal, non conductive materials and isolated conductors. 0 20
To unpainted metal Voltage ≤ 480V 20 (2)
Voltage < 600V(1) 20 (2)
Voltage = 690V(1) 20 (2)
To breaker housing 35 35 G
To conductors potruding from breaker 35 35
PG600 To painted metal, non conductive materials and isolated conductors. 0 30
To unpainted metal Voltage ≤ 480V 20 (2)
Voltage < 600V(1) 20 (2)

To breaker housing
Voltage = 690V(3) 20 (2)
60 60
X
To conductors potruding from breaker 60 60

(1) The use of phase seperators and back plates is obligatory. (3) At 690Volts the PG600 must have the power supply connected to the breaker ON side
(2) Size determined by phase seperators. (Line). In this application the use of the widened terminal shield is compulsory.

D.9
GuardEon
Derating

Thermal magnetic trip units

The ambient temperature in the direct vicinity of a The GuardEon breakers with thermal magnetic and
­protective device has an influence on its current ­carrying magnetic only protection units as the MO, LTM and LTMD
properties. types can be used at ­currents and ­temperatures as
­indicated in the table.

Maximum permissable current at an ambient temperature of


Fixed breaker Plug-in or draw-out breaker
Technical data

Type
In (A) 40°C 45°C 50°C 55°C 60°C 65°C 70°C 40°C 45°C 50°C 55°C 60°C 65°C 70°C
PE150 and 25 25.0 24.3 23.5 22.8 22.0 21.3 20.5 23.5 22.8 22.1 21.4 20.7 20.0 19.3
PE250 30 32.0 31.0 30.1 29.1 28.2 27.2 26.2 30.1 29.2 28.3 27.4 26.5 25.6 24.7
40 40.0 38.8 37.6 36.4 35.2 34.0 32.8 37.6 36.5 35.3 34.2 33.1 32.0 30.8
50 50.0 48.5 47.0 45.5 44.0 42.5 41.0 47.0 45.6 44.2 42.8 41.4 40.0 38.5
60 63.0 61.1 59.2 57.3 55.4 53.6 51.7 59.2 57.4 55.7 53.9 52.1 50.3 48.6
80 80.0 77.6 75.2 72.8 70.4 68.0 65.6 75.2 72.9 70.7 68.4 66.2 63.9 61.7
100 100 97.0 94.0 91.0 88.0 85.0 82.0 94.0 91.2 88.4 85.5 82.7 79.9 77.1
125 125 121 118 114 110 106 103 118 114 110 107 103 100 96
150 160 155 150 146 141 136 131 150 146 141 137 132 128 123
200 200 194 188 182 176 170 164 188 182 177 171 165 160 154
250 250 243 235 228 220 213 205 235 228 221 214 207 200 193

Intro

D.10
GuardEon
Derating

Electronic trip units

Electronic trip units are less sensitive to fluctuations in into account. The table indicates the maximum values to
­ambient temperature than thermal magnetic trip units. which the LT or overload protection of the ­electronic trip unit
However, to prevent the device and its environment from of the GuardEon breaker can be set. This at ambient
exceeding their design values, certain limits must be taken ­temperatures from 40 to 70°C.

Maximum permissable current at an ambient temperature of


Fixed breaker Plug-in or draw-out breaker
Type
In(1)(A) 40°C 45°C 50°C 55°C 60°C 65°C 70°C 40°C 45°C 50°C 55°C 60°C 65°C 70°C
PE150 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25
60 63 63 63 63 63 63 63 63 63 63 63 63 63 63

Derating
125 125 125 125 125 125 125 125 125 125 125 125 125 125 125
160 160 160 160 156 152 148 144 160 156 152 148 144 140 136
PE250 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125
150 160 160 160 160 160 160 160 160 156 152 148 144 140 136
250 250 250 250 244 238 231 225 250 244 238 231 225 219 213
PG600 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250
400 400 400 400 390 380 370 360 400 390 380 370 360 350 340
630 630 614 599 583 567 551 536 583 568 554 539 524 510 481

(1) Is = Sensor rating

Intro

D.11
GuardEon
Current limitation

A short-circuit is an overcurrent with a value only limited by In modern hi-power electrical distribution networks very
the impedance of the fault circuit itself. This ­impedance is high prospective fault levels of 100kA or more can occur.
determined by a number of factors the main ones of which High prospective short-circuit current values can cause
are the available power that a ­network can supply and the issues in a number of areas:
impedance of the ­conductors within the fault circuit.

Electrodynamic forces Thermal stress in Electrical conductors


These are proportional to the square of the crest current Cable have thermal stress limits normaly expressed in a
value. A2S value that depend on the cable´s cross section and
Technical data

The electrodynamical forces due to the crest current value its isolation. They are limited to prevent the insulation
can seriously damage equipment as busbar systems and conductor from exceeding their limit temperature.
their supports, downstream switchgear etc. Clause 434.5.2 of the IEC 60364-4-43 ed. 03 - 2008
Current limiting devices limit the crest value of the short- defines that for protection devices interrupting within 0.1
circuit current and thus reduce theses forces. seconds (t<=0.1 second) and current limiting devices as
GuardEon, the following formula applies:
Magnetic fields
A high level short-circuit produces magnetic fields that K2 x S2
­prevent electrical equipment as meters and computers K: factor provided in the standard; depends on the material
from operating correctly. that the conductor is made of and it's insulation
S: cross section of the conductor
Intro Thermal stress (heat)
Thermal stress is proportional to the square of the effective If the protection device is NOT current limiting.
current value. Clause 434.5.2 of the IEC 60364-4-43 ed. 03 - 2008
The thermal stress limit of cable isolation, busbar supports applies. Here for interruption times up to 5 seconds, the
A and other electrical equipment can be expressed as an regulation requires that the following formula is met.
A2S value. This electrical energy value must be kept within
certain pre-defined limits to prevent overheating. t = (K * S/I)2
B To avoid or to limit the effects of these issues the use of
current limiting devices is advisable.
Terminology
t: Duration of the short-circuit in seconds.
K: Factor provided by the standard; depending on the
material the conductor is made of and it's insulation.
C S: Cross Section of the conductor.
I: Effective short-circuit current. (r.m.s value)

Crest value and K factors in accordance with the IEC 60364-4-43 ed.03
D waveform without
current limitation. Insulation and maximum temperature Copper (Cu) Aluminium (Al)

Crest value and


PVC - 70° < 300 sq.mm 115 76
E waveform with
current limitation. PVC - 70° ≥ 300 sq.mm
PVC - 90° < 300 sq.mm
103
100
68
86
PVC - 90° ≥ 300 sq.mm 86 57
XLPE and EPR 90° 143 94
Rubber 60° 141 93
F Effect of a current limiting device
on a short-circuit in an AC network.
Mineral, bare unsheathed 105° 135 or 115(1) -

(1) The 115 value is be used for conductors exposed to touch.

G
Maximum permissible thermal stress in conductors
Cross section in sq. mm and maximum permissible thermal stress in A2s

X Insulation Core 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

x104 x104 x104 x104 x106 x106 x106 x106 x106 x108 x108 x108 x108 x108 x108 x108
PVC - 70° Cu 2.976 8.266 21.160 47.610 1.323 3.386 8.266 16.201 33.063 0.648 1.194 1.904 2.976 4.526 7.618 9.548
Al 1.300 3.610 9.242 20.794 0.578 1.479 3.610 7.076 14.440 0.283 0.521 0.832 1.300 1.977 3.327 4.162
PVC - 90° Cu 2.250 6.250 16.000 36.000 1.000 2.560 6.250 12.250 25.000 0.490 0.903 1.440 2.250 3.423 5.760 6.656
Al 1.664 4.623 11.834 26.626 0.740 1.893 4.623 9.060 18.490 0.362 0.667 1.065 1.664 2.531 4.260 2.924
XLPE and EPR 90° Cu 4.601 12.781 32.718 73.616 2.045 5.532 12.781 25.050 51.123 1.002 1.846 2.945 4.601 6.999 11.779 17.893
Al 1.988 5.523 14.138 31.810 0.884 2.262 5.523 10.824 22.090 0.433 0.797 1.272 1.988 3.024 5.090 7.784
Rubber 60° Cu 4.473 12.426 31.810 71.572 1.988 5.090 12.426 24.354 49.703 0.974 1.794 2.863 4.473 6.804 11.451 17.893
Al 1.946 5.406 13.838 31.136 0.865 2.214 5.406 10.595 21.623 0.424 0.781 1.245 1.946 2.960 4.982 7.784
Mineral bare 105°  k=135 Cu 4.101 11.391 29.160 65.610 1.823 4.666 11.391 22.326 45.563 0.893 1.645 2.624 4.101 6.238 10.498 16.403
Mineral bare 105°  k=115 Cu 2.976 8.266 21.160 47.610 1.323 3.386 8.266 16.201 33.063 0.648 1.194 1.904 2.976 4.526 7.618 11.903

D.12
GuardEon

GuardEon MCCBs revolutionary design is equipped The limitation of electrodynamic forces and thermal

Current limitation
with dual contacts placed in a rotary configuration that stress by using back-up protection
enables the device to provide the highest available Protection devices placed downstream from a
interruption ratings in the smallest possible size. When protective device as a GuardEon breaker must be able
the breaker reacts it does so with more than twice the to withstand the thermal and electrodynamic effects
speed and force of conventional breakers, thus ­providing that occur at its point of ­installation. Placing current
excellent current limitation. This results in low peak current limiting devices upstream limits these values and can
and energy values in the circuit and leads to lower allow the use of smaller and more economical devices
­electro-dynamic forces and thermal stress ­values in the than is possible without the use of current limitation.
protected electrical conductors, ­downstream
protection devices and equipment.

Intro

H
B
GuardEon PG630
PE250
Current limitation

However, in some cases it is still necessary to check if


D
the electrical conductors are protected correctly.
This can be verified by taking the cable stress limits
­published on the previous page and comparing them E
with the let-through energy values found in the graphs.
(page D.14 and D.15)

D.13
GuardEon
Environmental considerations

Ambient temperature Other atmospheric conditions

GuardEon breakers are designed to operate ­normally The breaker is designed


at temperatures of -20 degrees to +70°C. Above 40°C to operate at the tem-
derating factors must be applied for two basic reasons: peratures and relative
- To prevent the materials used to construct the device ­humidities defined in
from reaching temperatures that have an adverse the EN 60947 clause
effect on their mechanical and/or electrical properties. 6.1.3.1. It also meets the
- When the breakers is equipped with a thermal following ­standards:
­magnetic protection device the bimetal in the device
will react to the heat generated by the current flowing
Technical data

through the device.Typical for this kind of device is that


its reaction time speeds up at higher ambient IEC 68-2-1 Cold
IEC 68-2-2 Dry heat
­temperatures. IEC 68-2-14 Change of temperature
IEC 68-2-27 Shock test
IEC 68-2-29 Bump
IEC 68-2-30 Damp heat cyclic
To achieve the same IEC 68-2-31 Drop
reaction time on a
set current value it
becomes necessary
to derate.
Intro The time current Shock and vibration
curves published in
this catalogue are
always valid for oper- The GuardEon line has been designed to withstand shock
A ating temperatures and vibration to the following standards:
between 10 and 40°C. IEC 68-2-6
Germanischer Lloyd
B More specifically: GuardEon passed the
following electro-mechanical tests:
Storage temperature
Functions normally while being subjected to
C 30 minutes of random vibration with a power ­spectral
A GuardEon breaker is able to withstand density of 0.29g2/Hz in the range of 5Hz to 500Hz
non-­operational storage temperature ranges of (3dB corner points, ±20dB/decade rolloff),
this over three axes.(1)
D -40 to +85°C.

Functions normally
while being subjected
Influence of altitude
E to sinusoidal vibration
of 5g Peak from 10Hz
to 500Hz using 30
Up to altitudes of
minute sweeps with
F 2000 m above sea level
no derating of breaker
additional 30 minute
dwells at the three
current or rated voltage
greatest resonance
is a
­ pllicable. For
G ­altitudes above 2000 m
points in this frequency range, this over three axes.
the following factors
The product is shock resisitant and can withstand the
apply:
following impacts in any possible orientation:
X 20g, 6ms, 10g, 11ms (1)

Altitude
Altitude (meters) 3000m 4000m 5000m

Ue max. (Volts) 550V 480V 420V


Max. Thermal current at 40° C 0.98 x In 0.93 x In 0.9 x In
(1) Not applicable to PremEon S trip unit

D.14
GuardEon

Electromagnetic compatibility

Meets the most stringent requirement of the Electrostatic discharge


EN 60947-2 and IEC 1000-4. The breaker and ­electronic EN 70947 Annex F, Sub-clause F6 and the IEC 1000-4-2
trip unit have passed the following tests. Radiated, radio frequency, electromagnetic field
immunity test
EN 60947-2 Annex F, Sub-clause F7 and
Harmonics, current dips, interruptions and power the IEC 1000-4-3
frequency variations. Electrical fast transient/burst
EN 60947-2 Annex F, Sub-clause F4.1 through 3 EN 60947-2 Annex F, Sub-clause F5 and
All requirements of non-sinusoidal currents resulting the IEC 1000-4-4
from harmonics are met i.e: Surge immunity test

Environment
EN 60947-2 Annex F, Sub-clause F5 and
- Wave form the IEC 1000-4-5
consisting of a Dry heat test
fundamental EN 60947-2 Annex F, Sub-clause F8
component + 3rd Thermal shock test
harmonic EN 60947-2 Annex F, Sub-clause F9
component at
50 and 60Hz
- Wave form
consisting of a Intro
fundamental component + a 5th harmonic component
at 50 and 60Hz
- Composite wave form with a fundumental
component + 3rd, 5th and 7th and a harmonic at 50 A
and 60Hz
- All current dips and current interruptions are met.
- Frequency variation test from 45Hz to 65Hz in 1Hz
steps (required 50Hz to 60Hz in 1Hz steps)
B

D.15
GuardEon
Use in DC networks

In both AC and DC networks protective devices are However, the system voltage generally plays a greater role
required to interrupt the prospective short-circuit current (is more difficult to interrupt) while the network defines how
at the point where the device is installed. For circuit many poles need to participate in the ­interruption.
breakers as the GuardEon this value is called the The drawing below indicates the three possible DC
interuption or breaking capacity (Icu or Ics), a value ­networks with the "worst" short-circuit for each of them,
dependent not only on the prospective fault current value the number of poles that must particpate in the breaking
but also on the system voltage rating. For DC ­networks operation and the voltage level that needs to be
the situation is basically the same as for AC networks. ­interrupted.

Use in DC networks
Technical data

Network Type Center point connected to earth (A) One pole connected to earth (B) Insulated from earth (C)(1)

Electrical schemes




r Un-grounded system 2P in series for grounded system 2P in series for Un-grounded
system 2P in series for gro


Maximum short-circuit current (Icc max) short-circuit A-B short-circuit A-B or A-C short-circuit A-B
-/(+) Minimum poles needed 2 (one on each polarity) +/(-) polarity)
1 (unearthed -/(+) 2 (one on each pole)
Intro Breaking capacity on each pole Icc max at V/2 Icc max at V Icc max at V

+ 2P
- in series for Un-grounded
-/(+)2P insystem
series for Un-grounded
2P in seriessystem
for grounded 2P
system
in series for grounded system
Vs V
+ -
(1) When a pole is grounded due to a first fault nothing happens, on a second fault the network behaves like a system with "one polarity connected to ground"

A +/(-)
Typical DC connection2Pwiring
in series diagrams
for Un-grounded system
-/(+) +/(-) -/(+)
2P in series for grounded system
Vs Vs
AD 2P in series for
2P in series for Un-grounded Un-grounded system
system 2P in2Pseries- for grounded
+in series system
for grounded
LOAD + -
-/(+)
system -/(+)
+/(-) -/(+)

B +/(-)
LOAD
-/(+) Vs
+ - -/(+)

LOAD LOAD Vs
unded system 3P in series with + or – grounded + - 3P with Un-grounded
-/(+)
system 3P in series with + or – groun
C
3rd pole 2P in series andLOAD
3rd pole LOAD

LOAD for isolation

D-/(+) +/(-)
3P with Un-grounded
LOAD
-/(+)
system
3P with Un-grounded
3P in series with
system+ or – grounded
3P in series with-/(+)
+/(-) + or – grounded
LOAD
+/(-)
2P in series and 3rd pole 2P in series and 3rd pole LOAD
for isolation for isolation
3P with Un-grounded system - 2P in3P withand
series Un-grounded system 3P 3P
3rd pole for isolation in series with
in series + or+ –orgrounded
with – grounded
E 2P in series and 3rd pole
3P with
+/(-) Un-grounded -/(+)system+/(-) 3P in series -/(+)
+/(-) with + or – grounded
+/(-)
-/(+) -/(+)
for isolation
2P in series and 3rd pole
for isolation
LOAD
F LOAD
+/(-) -/(+)
LOAD
+/(-) -/(+)
LOA

+/(-) -/(+) +/(-) -/(+)

G LOAD LOAD LOAD LOAD


h + or – grounded 4P in series with Un-grounded system 4P in series with + or – grounded 4P in series with

X 4P in series with Un-grounded system LOAD 4P in series with + or – grounded


LOAD

-/(+)
4P in series with +
+/(-)
or – grounded
LOAD 4P in series with + or – 4P
-/(+)
grounded
in series with
LOAD Un-grounded
+/(-)
4P in series
systemwith Un-grounded
-/(+)
system
+/(-)

4P in series with + or – grounded 4P in series with Un-grounded system


4P +/(-)
in series with + or – grounded
+/(-) -/(+) 4P in series with-/(+)
+/(-) Un-grounded system
+/(-)
-/(+) -/(+)

LOAD LOAD LOAD


+/(-) -/(+) +/(-) -/(+)

+/(-) -/(+) +/(-) -/(+)

LOAD LOAD LOAD LOAD


D.16

LOAD LOAD
GuardEon
Use in DC networks

GuardEon PE and PG line breakers can be used in DC Example


networks with standard thermal ­magnetic trip units. Rated voltage 500V DC; Rated current 200A Icc
max 50kA
For GuardEon PG line breakers, please contact us. network A: center point connected to grond
PE250N 3x250 - 1 pole for each polarity
The nominal current rating of the device does not vary in AC network B: one pole connected to ground
or DC applications. The setting of the short-circuit or magnetic PE250N 3x250 - 2 poles on unearthed polarity
device needs to be ­multiplied by 1.2 to ­determine its thresh- network C: insulated network
old in a DC network. The table indicates the nominal current, PE250N 3x250 - 1 pole for each polarity
the breaking capacity (Icu=Ics) and the number of poles

Current-Limiting
needed to participate in the interruption.

Use in DC networks with standard thermal magnetic trip units

Breaker Rated current 110V DC 250V DC 440V DC 500V DC Thermal threshold Magnetic
­threshold

PE150N 25~150 50 (1p) 50 (2p) 50 (3p) 50 (3p) = AC 1.2


PE150H 25~150 85 (1p) 85 (2p) 85 (3p) 85 (3p) = AC 1.2
PE150L 25~150 100 (1p) 100 (2p) 100 (3p) 100 (3p) = AC 1.2
PE250V 125~250 25 (1p) 25 (2p) 25 (3p) - = AC 1.2
PE250N 125~250 50 (1p) 50 (2p) 50 (3p) 50 (3p) = AC 1.2
PE250H 125~250 85 (1p) 85 (2p) 85 (3p) 85 (3p) = AC 1.2
PE250L 125~250 100 (1p) 100 (2p) 100 (3p) 100 (3p) = AC 1.2 Intro

D.17
Smart, Reliable and Secure
GuardEon

The circuit breaker Intro

Order codes A

E.2 Introduction Trip units B


E.4 Protection against short-circuit
E.8 Personnel protection (direct and indirect contact) Components and accessories C
E.14 Selectivity/Discrimination
E.15 Back-up protection Technical data D
E.34 Protection of motor circuits (coordination type 2)
Application guide E

Wiring diagrams F

Dimensions G

Numerical Index X

E.1
GuardEon
Introduction
A protection device like the GuardEon circuit ­breaker is Phase and Neutral conductors
used in a wide variety of environments to protect con- Clause 431.1(1) of the IEC 60364 states that overcurrent
ductors, equipment and devices in low ­voltage distribu- detection and disconnection shall be provided for all
tion circuits. To use this product to its full potential it is live conductors.
necessary to verify that it ­functions correctly in the In TN and TT systems no neutral overcurrent protection
environment in which it is used and that it meets the is required if the neutral cross section is at least equivelant
Electrotechnical ­requirements of the circuit it protects. to that of the line conductors and the current is not
expected to exceed that in the line conductors.
Environment However, if this condition is not met a neutral current
GuardEon breakers function well in almost any indus- detection device is required that disconnects the line
Application guide

trial environment. The IEC 60947 defines the main protection devices on the detection of a fault.
aspects of what is meant by "industrial ­environment": For IT systems where the neutral is distributed (NOT recom-
Temperature: mended) each circuit shall be provided with a line and
Relative humidity: neutral overcurrent protection and disconnection device.(1)
Altitude:
Pollution: Harmonic currents
Network harmonic content: Clause 431.2.3 of the IEC 60364 requires that if the har-
Shock and vibration resistance: monic content of the line currents is such that a current
For conditions other than the above mentioned please in the neutral is expected that exceeds the neutrals
refer to page D.16 in which the effects of the current carrying capacity, overcurrent detection is
­environment are defined. required. The detection shall be compatible with the
nature of the current in the neutral and shall cause dis-
Maximum short-circuit current
Intro Protective devices as the GuardEon circuit breaker
connection of the line conductors.

must be able to interrupt the maximum short-circuit Breaker parameters


current at the point where they are installed. GuardEon breakers are available equipped with 2, 3, and 4
A The interruption ratings or breaking capacities of these pole overload detection, protection and interruption
breakers can be found in section D of this catalogue. devices. Multiple Neutral protection modes being available.
The short-circuit ratings at the point of installation of In 4 pole devices the neutral pole always operates
these devices can be determined by the use of software simultaneously with those present in the phases.
B as Procera plus. A method to calculate these values
conventionally is described on page E.4 and E.5 of this Each breaker has a minimum of two protection devices:
catalogue. - Overload Protection Device.
C (In electronic devices - LT setting)
- Short Circuit Protection Device.
Design current of a circuit (In electronic devices - ST or I setting)
The equipment and devices in an electrical circuit
D determines it's current load. The electrical ­conductor Electronic Trip Units have extended protection features
cross sections that can be used in the circuit are including:
­determined by a number of factors i.e. - LT or Overload Protection device.
- ST or Time delayed Short Circuit Protection device.
E - The design current of the circuit (IB). - I or Instantaneous Short Circuit Protection device.
- Conductor type and it's insulation. Optionally
(current capacity = IZ) - Gfsum.
F - Installation method.
- Temperature. Overload or LT setting
- Number of conductors mounted in each others Referred to as Ir in the IEC 60364 the setting is determined
­vicinity. by the use of two following formulae.
G IB < Ir ≤ IZ
The resulting combinations of current load and It ≤ 1.45 x IZ
­electrical conductor cross sections are beyond the Terminology
X scope of this catalogue, however a number of
­frequently used values are:
IB = Circuit design current
Ir = Current set on breaker
IZ = Current carrying capacity of electrical conductor
It = Tripping current of the protection device
(GuardEon MCCB It ≤ 1.3 x Ir)

Conductor cross section 10mm2 25mm2 50mm2 70mm2 95mm2


Use of the above mentioned formulae and the
GuardEon characteristics give the following results:
IB with Cu conductors in A 50 90 130 170 210 Breaker setting Ir ≤ IZ (It ≤ 1.3 x IZ)
IB with AL conductors in A 35 70 100 130 160
In practice Ir is generally set at a value equal to IZ.

(1) In certain specific cases deviations are allowed.

E.2
GuardEon

Magnetic setting (Im) or ST setting Ground Fault setting (GF) on Electronic breakers
Protected Equipment All larger Electronic GuardEon breakers can be option-
The magnetic or ST setting of a breaker (Im) is ­primarily ally equipped with a GF sum device that operates on a
defined by the characteristics of the ­equipment and Residual Current principle.
devices in the circuit. It 'sums' the values of the secondary circuits in the
The GuardEon device is equipped with trip units that installed sensors in both the lines and Neutral pole and
react to fault currents when needed but are specifically sends an alarm or trip signal when this value is <> to
designed not to react to most inrush-­current profiles. zero and exceeds the adjusted values.
This device allows the user to set a 'fault' current value

Performance figures
The details included in this section on devices as LV/LV
transformers and the time current curves of the ­breaker (Id) ranging from 02. to 1 times the breaker sensor rating
and a trip time delay.
published elsewhere in this catalogue allow a definition
Where the standard breaker settings are insufficient a
of the Im value.
GFsum device allows the detection of low short-circuit
values as the weakest short-circuit current and/or a
Instantaneous setting (I) on Electronic breakers
current to earth (Fault Current).
All Electronic GuardEon breakers are equipped with this
protection device that on detection of a short-circuit
exceeding it's set value trip the breaker immediately.
The device has a fixed setting on all SMR1 devices and
can be adjusted on all SMR2 trip unit types.
It is primarily used to limit the electrical energy level in
the circuit (vs. the timed short-circuit setting ST).

Magnetic setting (Im) or ST setting


Protected Lines
Intro
On a short-circuit event the total circuit impedance
determines the highest and the lowest current that can
flow in the circuit. It is necessary not only to verify if A
the protective device can interrupt the ­maximum ­­
short-circuit value but also if the device protecting the
circuit reacts and disconnects in time at the lowest
possible short-circuit value. B
Due to the fact that a major part of the circuit
­impedance is formed by electrical conductors like
cables, busbar systems etc. within the circuit, this C
requirement has a limiting effect on the length of the
­conductors used in the circuit.

There are two conditions that have to be met:


D
a) The weakest short-circuit current must be
­disconnected before the electrical conductors
exceed their temperature limits. E
b) A current to earth (fault current) must be
­disconnected before inadvertent contact to
­normally non-conductive parts causes injury.
Please refer to the pages E.6 and E.13 for more details. F

E.3
GuardEon
Protection against short-circuits

Maximum short-circuit ratings


Protective devices such as the GuardEon circuit breaker Calculated maximum short-circuit values (3 phase 400V network)
must be able to interrupt the maximum short-circuit
current at the point where they are installed. MV/LV Transformer(s) Medium Voltage power SKQ in MvA

The ­interruption ratings of these breakers (breaking SrT Ukr % 100 150 200 300 400 500
kvA Maximum short-circuit Values in kA (Ik3max)
capacity) can be found elsewhere in this catalogue.
For the calculation of the short-circuit current at the 100 4 3.5 3.6 3.6 3.6 3.6 3.6
160 4 5.6 5.7 5.7 5.7 5.7 5.8
point where the breaker is installed a pan-European 250 4 8.5 8.7 8.8 8.9 8.9 9.0
­document is now available in the form of the ­R064-003. 315 4 10.6 10.9 11.0 11.1 11.2 11.2
Application guide

400 4 13.2 13.6 13.8 14.0 14.2 14.2


The values published here are based on this document. 500 4 16.2 16.8 17.1 17.4 17.6 17.7
630 4 19.8 20.7 21.2 21.7 22.0 22.2
Power supply 630 5 16.3 16.9 17.2 17.6 17.7 17.8
630 6 13.8 14.3 14.5 14.7 14.8 14.9
The values mentioned in table indicate the effective values 800 6 17.1 17.8 18.2 18.5 18.7 18.8
of the highest three phase short-circuit ­current that is 1000 6 20.8 21.8 22.3 22.9 23.2 23.4
available at the connection terminals of the incoming 1250 6 25.1 26.6 27.4 28.3 28.7 29.0
1600 6 30.6 32.9 34.2 35.6 36.3 36.8
transformer(s). 2000 6 36.4 39.7 41.6 43.6 44.7 45.4
2500 6 42.9 47.5 50.2 53.2 54.8 55.9
2 x 400 4 24.2 25.7 26.4 27.2 27.7 27.9
2 x 500 4 29.1 31.2 32.3 33.5 34.2 34.6
Incoming transformers 2 x 630 4 34.9 37.9 39.6 41.4 42.4 43.0
2 x 630 5 29.3 31.4 32.5 33.8 34.4 34.8
2 x 630 6 25.3 26.8 27.6 28.5 29.0 29.3
2 x 800 6 30.6 32.9 34.2 35.6 36.3 36.8
Intro 2 x 1000
2 x 1250
6
6
36.4
42.9
39.7
47.5
41.6
50.2
43.6
53.2
44.7
54.8
45.4
55.9
2 x 1600 6 50.7 57.3 61.3 65.9 68.4 70.0
2 x 2000 6 58.3 67.3 72.8 79.4 83.1 85.5
2 x 2500 6 66.3 78.1 85.7 94.9 100.3 103.9
A 3 x 400
3 x 500
4
4
33.6
39.7
36.4
43.7
37.9
45.9
39.6
48.5
40.5
49.8
41.1
50.7
3 x 630 4 46.8 52.3 55.6 59.4 61.4 62.7
3 x 630 5 40.0 43.9 46.2 48.8 50.2 51.0
3 x 630 6 34.9 37.9 39.6 41.4 42.4 43.0
B 3 x 800
3 x 1000
6
6
41.6
48.6
46.0
54.6
48.5
58.2
51.3
62.3
52.8
64.6
53.8
66.0
Installation 3 x 1250 6 56.1 64.3 69.3 75.3 78.6 80.8
3 x 1600 6 64.8 76.1 83.3 91.9 97.0 100.3
3 x 2000 6 72.9 87.5 97.2 109.2 116.4 121.2
C 3 x 2500 6 81.0 99.4 112.1 128.6 138.7 145.6
Formulas
Medium voltage impedance
Terminology
D ZQ =
(m x Uo x √3)2
mΩ
SkQ
SrT
= short-circuit power of the medium/high ­voltage network
= power rating of the MV/LV transformer
SkQ Ukr = short-circuit voltage in %, according to HD 398
MV/LV transformer impedance
m = no load factor; 1.05 assumed
E
(m Uo sqrt 3)2 U Cmax. = voltage factor; 1.05 assumed
Zr = x   kr  mΩ Uo = phase to neutral voltage
S r T 100% Ik3max = maximum 3 phase short-circuit current
Maximum short-circuit calculation X = total reactance
F (Cmax. x m x Uo x √3)2
XQ
X T
=
=
0.995 x ZQ
0.95 x Z T
Ik3max = kA R = total resistance
√R2 + x2 R Q = 0.1 x XQ

G RT

= 0.31 x Z T

E.4
GuardEon

Influence of cable runs

Protection against short-circuit


It is possible to calculate short-circuit values within Short-circuit values within circuits
­circuits by determining the ­impedance, ­reactance and
resistance of the power supply and by adding those of Ik3 max. without IK3 max in kA at point where GuardEon MCCB
cable run is to be installed (This value must be ≤ Icu or Ics)
cable runs. These values are used here to ­calculate the
maximum short-circuit levels at the end of a defined 145 80 65 50 30 25 22 20 15 10 6
140 80 65 50 30 25 22 20 15 10 6
cable run.
130 80 65 50 30 25 22 20 15 10 6
120 80 65 50 30 25 22 20 15 10 6
Values used 110 80 65 50 30 25 22 20 15 10 6
100 65 65 50 30 25 22 20 15 10 6
Specific resistance of copper and aluminum at 20°C 90 65 65 50 30 25 22 20 15 10 6
80 65 50 50 30 22 20 20 15 10 6
ρ0 = 18.51 mΩ mm2/m. for copper cores 70 65 50 50 25 22 20 20 15 10 6
60 50 50 50 25 22 20 20 15 10 6
29.41 mΩ mm2/m. for aluminum cores 50 50 36 36 22 20 20 20 15 10 6
45 50 36 30 22 20 20 20 15 10 6
40 36 36 30 20 20 20 15 15 10 6
Reactance of multicore cables λ 0.08 mΩ /m.
35 30 30 25 20 20 15 15 15 10 6
30 30 25 22 20 20 15 15 15 10 6
Examples 25 22 22 20 15 15 15 15 10 10 6
20 - - - 15 15 15 15 10 10 6
Ik3 max. at cable run start 50kA 15 - - - - - 10 10 10 10 6
54 meters of 185 mm2 cable 10 - - - - - - - - 6 6
Ik3 max. at cable run end 22kA

Ik3 max. at cable run start 120kA Cable cross section Required minimum length in meters of cable run of the mentioned
Cu mm2  AL mm2 cross section to achieve the Ik3 max mentioned above
Intro
12 meters of 185 mm2 cable
Ik3 max. at cable run end 80kA 1.5 0.5 0.5 0.5 1 1 1 1 1.5 2 3.5
2.5 4 0.5 0.5 0.5 1 1.5 1.5 1.5 2 3.5 5.5
4
6
6
10
0.5 0.5 1 1.5 2 2.5 2.5 4
1 1 1.5 2.5 3 3.5 3.5 5
5
8
9
13
A
10 16 1 2 2 4 5 5.5 6 8 13 21
16 25 1.5 2.5 3.5 6 8 9 10 13 20 35
25 35 2.5 4 5 9 12 13 15 20 32 55
35
50
50
70
3
4
4
6
7 13 16 18 20 28 42
9 18 22 25 29 39 60
70
100
B
70 95 6 8 12 24 30 35 40 55 85 135
2 x 35 2 x 50 6 8 13 25 32 36 40 55 85 140
95 150 7 11 16 32 39 46 51 70 110 180
2 x 50
120
2 x 70
185
8 12 18 35 44 52 58 80 120
9 13 19 38 48 55 62 85 130
200
220
C
150 240 10 15 23 46 58 66 75 100 155 255
2 x 70 2 x 95 11 16 24 50 60 70 80 110 170 270
185 12 18 27 54 65 76 84 116 180 300
240
2 x 95 2 x150
14 21 32 32 78 88 98 135 210
14 21 32 65 80 95 105 140 220
340
360
D
300 16 24 35 70 85 100 110 150 230 380
Run length 2 x120 2 x185 17 27 42 80 95 110 125 170 260 430
2 x150 20 30 48 91 115 135 150 200 310 510
3 x 95
2 x185
3 x150 21 33 51 95 120 140 155 210 320
23 35 53 105 130 155 170 235 360
540
590
E
3 x120 25 38 57 115 145 165 185 255 390 645
2 x240 28 41 62 125 155 180 200 270 410 675
3 x150 3 x240 30 45 68 140 170 200 220 300 460 765
3 x185
3 x240
35 53 79 160 195 230 255 350 530
41 80 125 185 230 265 295 410 620
880 F

E.5
GuardEon
Protection against short-circuits

Weakest short-circuit current


It is necessary to verify that the permissible thermal Under normal conditions it is assumed that the current
stress in conductors is not exceeded at the ­maximum setting of the Magnetic or ST device and the associated
short-circuit level and at the weakest short-circuit level. tripping time is used to verify if this condition is met. This
Verification on the maximum short-circuit level is current value can be used to verify if the breaker trips on
described on page E.4 of this ­catalogue. For the w­ eakest the weakest short-circuit current.
short-circuit value it is necessary to verify that the In certain cases (specifically with Electronic Trip Units) a
protective devices as the GuardEon circuit breaker lower current level with an interruption time of 5 seconds
trips before the conductors reach the ­mentioned limits, can be assummed.
Application guide

this for operating times of 0.1 to 5 seconds.


Weakest short-circuit current calculations
Permissible thermal stress in conductors For the most commonly applied network ­configuration,
Clause 434.5.2 of the IEC 60364 4d. 03 - 2008 defines 3 phase with neutral, the weakest short-circuit is the
that for interruption times between 0.1 and 5 seconds, Phase to Neutral value.
the following formula applies: The network configuration determines the value of this
current. Cases where the Phase to Earth or two Phase
t = (k* S/l)2  or it's equivelant  k2 S2= I2t value is the weakest are also commonplace.
Basically, the weakest short-circuit current is ­determined
Terminology by the highest impedance loop in the ­circuit that the
t = duration of the short-circuit in seconds breaker is protecting.
k = factor provided by the standard; depending on the material
The impedance of this loop is mainly determined by the
the conductor is made of and it's insulation
Intro S = cross section of the conductor conductors ­included in the circuit, thus their maximum
I = effective short-circuit current . (r.m.s value) length is ­limited. An ­approximation of the effect of the
­conductor or cable length on the weakest short-circuit is
The tables included here indicates the factor k for conduc- possible by using the following formula:
A tors with different insulation materials and the calculated
energy values (K2 S2 values in A2S). Ikmin= 0.8 x   Cmin x Uo   x k1 x k2 x k3 Amp
√R2 + x2
GuardEon Circuit breaker application
B To meet this condition it is necessary to verify if the I2t Terminology
value of the protection device is lower than or equal to Ikmin = Weakest short-circuit current
the K2 S2 value of the used conductors for interruption 0.8 = Assumed factor for the impedance of the upstream ­network

C times between 0.1 and 5 seconds.


Cmin
Uo
=
=
Voltage factor; 0.95 assumed
Phase to neutral voltage
X = Reactance of the conductors or cables in the circuit
reactance of multi core cables X in mΩ/m 0.08
K factors in accordance with the IEC 60364-4-43 ed.03 R = Resistance of the conductors or cables in the circuit based
D on the following basic data: (warm state)
Insulation and maximum temperature Copper (Cu) Aluminium (Al) 22.069 mΩ mm2/m. for copper cores(2)
37.178 mΩ mm2/m. for aluminum cores(2)
k1, k2 k3 = Correction factors, see next page
PVC - 70° < 300 sq.mm 115 76
E PVC - 70° ≥ 300 sq.mm
PVC - 90° ≤ 300 sq.mm
103
100
68
66
PVC - 90° > 300 sq.mm 86 57 (2) = 1.28 x 17.241 and 1.28 x 28.264 (see IEC 60364-4-43)
XLPE and EPR 90° 143 94
Rubber 60° 141 93
F Mineral, bare unsheathed 105° 135 or 115(1) -

(1) The 115 value is be used for conductors exposed to touch.

G
Maximum permissible thermal stress in Conductors for operating times from 0.1 to 5 seconds
Cross section in sq. mm and maximum permissible thermal stress in A2s
X Insulation Core 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

x104 x104 x104 x104 x106 x106 x106 x106 x106 x108 x108 x108 x108 x108 x108 x108
PVC - 70° Cu 2.976 8.266 21.160 47.610 1.323 3.386 8.266 16.201 33.063 0.648 1.194 1.904 2.976 4.526 7.618 9.548
Al 1.300 3.610 9.242 20.794 0.578 1.479 3.610 7.076 14.440 0.283 0.521 0.832 1.300 1.977 3.327 4.162
PVC - 90° Cu 2.250 6.250 16.000 36.000 1.000 2.560 6.250 12.250 25.000 0.490 0.903 1.440 2.250 3.423 5.760 6.656
Al 1.664 4.623 11.834 26.626 0.740 1.893 4.623 9.060 18.490 0.362 0.667 1.065 1.664 2.531 4.260 2.924
XLPE and EPR 90° Cu 4.601 12.781 32.718 73.616 2.045 5.532 12.781 25.050 51.123 1.002 1.846 2.945 4.601 6.999 11.779 17.893
Al 1.988 5.523 14.138 31.810 0.884 2.262 5.523 10.824 22.090 0.433 0.797 1.272 1.988 3.024 5.090 7.784
Rubber 60° Cu 4.473 12.426 31.810 71.572 1.988 5.090 12.426 24.354 49.703 0.974 1.794 2.863 4.473 6.804 11.451 17.893
Al 1.946 5.406 13.838 31.136 0.865 2.214 5.406 10.595 21.623 0.424 0.781 1.245 1.946 2.960 4.982 7.784
Mineral bare 105° k=135 Cu 4.101 11.391 29.160 65.610 1.823 4.666 11.391 22.326 45.563 0.893 1.645 2.624 4.101 6.238 10.498 16.403
Mineral bare 105° k=115 Cu 2.976 8.266 21.160 47.610 1.323 3.386 8.266 16.201 33.063 0.648 1.194 1.904 2.976 4.526 7.618 11.903

E.6
GuardEon

Maximum conductor length

Protection against short-circuit


To meet the short-circuit requirements the circuit Maximum Cu conductor length in meters based on a Phase to Neutral
voltage (Uo) of 230V and valid for multicore conductors with stress
breaker (Im) must react to the weakest short-circuit
calculations based on a k of 100
current. The table indicates the ­maximum cable length (Areas in grey indiacte that stress requirements are exceeded)
where this condition is still met.
The tolerances on the settings of the short-­circuit Cross Discon- GuardEon Im or ST setting in Amps & conductor length in Meters
section S nection 50 75 100 125 150 175 200 250 300 350 400
device in the breaker are taken into account (factor in mm2 time (s)
included in calculations of 1.2). 1.5 0.10 99 66 50 40 33 28 25 20 17 14 12
2.5 0.10 165 110 83 66 55 47 41 33 28 24 21
4 0.10 264 176 132 106 88 75 66 53 44 38 33
Correction factors k 6 0.10 396 264 198 158 132 113 99 79 66 57 49
For a 3 phase circuit with no neutral and a voltage of 10 0.10 660 440 330 264 220 188 165 132 110 94 82
400V between phases: 16 0.10 1054 703 527 422 351 301 264 211 176 151 132
25 0.50 1643 1096 822 657 548 470 411 329 274 235 205
k1 = 1.74 35 0.50 2292 1528 1146 917 764 655 573 458 382 327 286
50 0.50 3247 2165 1624 1299 1082 928 812 649 541 464 406
70 0.50 4479 2986 2239 5516 1493 1280 1120 896 746 640 560
For a single phase circuit with neutral and a voltage of 95 1.05 5929 3953 2964 5295 1976 1694 1482 1186 988 847 741
230V between phase and neutral: 120 1.05 7263 4842 3632 4900 2421 2075 1816 1453 1211 1038 908
k1 = 1.00

For a 3 phase circuit with neutral, a voltage of 400V Cross Discon- GuardEon Im or ST setting in Amps & conductor length in Meters
section S nection 450 500 600 700 800 900 1000 1250 1500 1750 2000
between phase and a neutral with 0.5 x the phase cross in mm2 time (s)
section: 2.5 0.10 18 17 14 12
k1 = 0.67 4
6
0.10
0.10
29 26 22 19 16 15 13
44 40 33 28 25 22 20 16 13 11 Intro
10 0.10 73 66 55 47 41 37 33 26 22 19 16
For a number of multi-core cables in parallel 16 0.10 117 105 88 75 66 59 53 42 35 30 26
25 0.10 183 164 137 117 103 91 82 66 55 47 41
k2 for 2 cores = 2.00
k2 for 3 cores = 2.65
35
50
0.10 255 229 191 164 143 127 115 92 76 65 57
0.10 361 325 271 232 203 180 162 130 108 93 81 A
70 0.50 498 448 373 320 280 249 224 179 149 128 112
95 1.05 659 593 494 423 371 329 296 237 198 169 148
For multicore cables with conductors made of ­aluminum: 120 1.05 807 726 605 519 454 404 363 291 242 208 182
150 1.05 966 870 725 621 544 483 435 348 290 249 217
185 1.05 1127 1014 845 724 634 563 507 406 338 290 254 B
240 1.05 1328 1195 996 854 747 664 598 478 398 341 299
300 1.05 1489 1340 1117 957 838 745 670 536 447 383 335
Cu conductor Cross section k3
S in mm2

= 4 ≤ 50 0.63 Cross Discon- GuardEon Im or ST setting in Amps & conductor length in Meters
C
70 0.64 section S nection 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
95 0.65 in mm2 time (s)
120 0.66 10 0.10 13 11 9
150
185
0.67
0.69
16
25
0.10
0.10
21 18 15 13
33 27 23 21 18 16 15 14 13 12 11
D
240 0.72 35 0.10 46 38 33 29 25 23 21 19 18 16 15
300 0.76 50 0.10 65 54 46 41 36 32 30 27 25 23 22
70 0.50 90 75 64 56 50 45 41 37 34 32 30
95
120
0.50 119 99 85 74 66 59 54 49 46 42 40
0.50 145 121 104 91 81 73 66 61 56 52 48
E
150 1.05 174 145 124 109 97 87 79 72 67 62 58
185 1.05 203 169 145 127 113 101 92 85 78 72 68
240 1.05 239 199 171 149 133 120 109 100 92 85 80
300 1.05 268 223 191 168 149 134 122 112 103 96 89 F
Cross Discon- GuardEon Im or ST setting in Amps & conductor length in Meters
section S nection 8000 8500 9000 9500 10000 11000 12000 13000 14000 15000 16000
in mm2 time (s) G
35 0.10 14 13 13 12 11 10
50 0.10 20 19 18 17 16 15 14 12 12 11
70 0.50 28 26 25 24 22 20 19 17 16 15 14
95
120
0.50
0.50
37 35 33 31 30 27 25 23 21 20 19
45 43 40 38 36 33 30 28 26 24 23 X
150 1.05 54 51 48 46 43 40 36 33 31 29 27
185 1.05 63 60 56 53 51 46 42 39 36 34 32
240 1.05 75 70 66 63 60 54 50 46 43 40 37
300 1.05 84 79 74 71 67 61 56 52 48 45 42

Notes
The disconnection time of 0.1 second is the lowest value defined in the
standard and can be applied for the GuardEon PE150 and PE250 breaker
types.
The 0.5 second disconnection times can be used for all GuardEon breaker
types PG600. (with and without time setting).
For cross sections >70 sq.mm the use of breakers with time a setting of
1 second as the EntelliGuard ACB is assummed. The resulting cable lengths
also apply for GuardEon breakers.

E.7
GuardEon
Protection against Electric Shock GuardEon Circuit breakers
The 2001 edition of the IEC 60364-4-41 protection under As molded case circuit breakers the GuardEon meet a
normal conditions was referred to as 'direct contact and number of the requirements of basic protection.
protection under fault conditions was referred to as The double isolated casing offering a so called class II
'Protection against indirect contact'. protection. The device when installed with cover plates
In the 2005 edition of the same standard the general and accessories as terminal shields offers a protection
terminology 'Protection against Electrical shock' has been degree of up to IP40 or IP54.
adapted whilst two new terms have been introduced: When used for fault protection to automatically discon-
nect the supply GuardEon meet the required automatic
1) Protection under normal conditions now designated: disconnection times across a broad, adjustable current
Basic Protection range. Where this current range does not suffice an RCD
Application guide

2) Protection under fault conditions now designated: device can be added to breakers with ratings up to 600A
Fault protection whilst the GFsum option using a Residual Current Principle
can be applied on larger breakers.
Basic protection being provided by basic insulation of
live parts, barriers or enclosures whilst fault protection
is provided by protective equipotential bonding and
automatic disconnection in case of a fault in TN, TT and
IT systems.
The Protective measure:
automatic disconnection of the power supply
being described in paragraph 411.
(Replacing paragraph 413 of the 2001 edition)
Intro
Generally, the required automatic disconnection time
depends on the configuration of the system and the
A nominal voltage between line and earth (Uo). It is defined
in clause 411.3.2.2 and table 41.1 of which an extract can
be found on this page.
In addition to this table the following general requirements
B are put forward:

In TN systems, a disconnection time not exceeding 5


C seconds is permitted for distribution circuits and circuits
larger than 32A. (Not applicable in Belgium where table
41.1 applies generally)

D In TT systems, a disconnection time not exceeding 1


second is permitted for distribution circuits and circuits
larger than 32A.

E In IT systems an automatic disconnection of the supply


is generally not required on the first fault (Except in
Norway). On a second fault, depending on the systems
F configuration, a disconnection time not exceeding 1 second
or 5 seconds is permitted for distribution circuits and
circuits larger than 32A.

G If the automatic disconnection times cannot be


achieved in the required time supplementary protective
equipotential bonding shall be provided.
X In all network configurations it is necessary to ensure
that the protective device will interrupt the circuit
within the defined automatic disconnection times.
Verification being necessary for the worst case scenario
taking into account the Phase to Earth voltage, the fault
current and the characteristics of the protection device.

E.8
GuardEon
TT system characteristics TN system characteristics
One point of the power supply is connected to earth One or more points of the power supply are ­connected
whilst all conductive parts in the installation are to earth whilst all conductive parts in the installation
­connected to electrically independent earth ­electrodes. are electrically connected to this point by protective
conductors. (PE or PEN conductors). The system exits in
three main variants:
L1
L2
TNC The neutral and protective conductor are
L3 ­combined. (PEN)
1 N TNS The neutral(N) and protective conductor (PE)
are separate.

Personnel protection
7
TNCS The supply is configured as a TNC, the system
3
changes to a TNS system at a ­­
pre-defined point in the LV installation.
5
4 TNC
6 6 L1
L2
L3
2 1 PEN
7
8

1 Power supply. 3
2 Power supply earthing (RN)
3 Low voltage installation, consumer portion.
4 Equipment present in installation. 5

5 Exposed conductive parts/surfaces. 4


Intro
6 Installation earthing. (RA)
7 Recommended RCD device.
2 6

Under fault conditions disconnection of the supply may A


be assured by an overcurrent device as GuardEon pro- 1 Power supply.
vided a suitably low value of the fault circuit impedance Zs 2 Power supply earthing.
is reliably assured. The following condition shall then be 3 Low voltage installation, consumer portion. B
fulfilled: 4 Equipment present in installation.
Zs x Ia ≤ U0 5 Exposed conductive parts/surfaces.
where: 6 Additional supply earthing.
Zs = the impedance in Ω of the fault loop compromising 7 Protective conductor combined with the neutral. C
- the Source 8 Protective device.
- the line conductor up to the point of the fault
- the protective conductor of the exposed parts
- the earthing conductor
- the earth electrode of the installation (RA)
TNS
L1
D
- the earth electrode of the source (RN) L2
Ia = the current in A causing the protection device to disconnect L3
N
E
1
within the time as specified in table 41.1 (see excerpt on page E.8)
PE
or within 1 second depending on the stipulated requirements 6
U0 = the nominal a.c. or d.c. line to earth voltage 7

3
F
5

G
4
0

X
1 Power supply.
2 Power supply earthing.
3 Low voltage installation, consumer portion.
4 Equipment present in installation.
5 Exposed conductive parts/surfaces.
6 Protective conductor.
7 Protective device.

Remark: a TNCS system is not depicted

E.9
GuardEon
TN system Characteristics (ct'd)
Under fault conditions disconnection of the supply may It is recommended that the first fault to earth is elimi-
be assured by overcurrent devices as GuardEon. nated as soon as possible. To indicate the first fault
The following condition shall then be fulfilled: between a live part to exposed conductors or earth
Zs x Ia ≤ U0 insulation monitoring devices shall be provided.
where:
Zs = the impedance in Ω of the fault loop compromising After the ocurrence of a first fault a second fault on a
- the Source different live conductor shall result in an automatic
- the line conductor up to the point of the fault
disconnection of the supply.
- the protective conductor of the exposed parts
Ia = the current in A causing the protection device to disconnect Where exposed conductive parts are interconnected by
within the time as specified in table 41.1 (see excerpt on page E.8) a protective conductor collectively linked to the same
Application guide

or within 5 seconds depending on the stipulated requirements. earthing system an IT is very similar to a TN system to
U0 = the nominal a.c. or d.c. line to earth voltage. which the following condtions apply.

If the neutral or mid point conductor is not distributed


IT system characteristics the following condition must be fulfilled:
2 x Zs x Ia ≤ U
The supply is isolated from earth or connected to earth
by means of an impedance of a relatively high value. If the neutral or mid point conductor is distributed
The conductive parts in the installation are connected the following condition must be fulfilled:
to earth ­electrodes. 2 x Z's x Ia ≤ U0
L1
where:
L2 Zs = the impedance in Ω of the fault loop compromising
- the line conductor and the protective conductor of the circuit.
Intro 1
L3
Z's = the impedance in Ω of the fault loop compromising
8 - the neutral conductor and the protective conductor of the circuit.
Ia = the current in A causing the protection device to disconnect
3 within the time as specified in table 41.1 for TN systems (see
7
A excerpt on page E.8) or within 5 seconds depending on the
stipulated requirements.
5 U = the nominal a.c. or d.c. line to line voltage.
4 U0 = the nominal a.c. or d.c. line to neutral or mid -point conductor
voltage.
B
6
Where the exposed conductive parts are earthed in
groups or individually the supply must be disconnected
2
C within the time as specified in table 41.1 for TT systems
(see excerpt on page E.8) or within 1 second depending on
1 Power supply. the stipulated requirements and the following conditon shall
2 Power supply earthing. be fulfilled:
D 3 Low voltage installation, consumer portion. RA x Id ≤ 50V
4 Equipment present in installation. where:
5 Exposed conductive parts/surfaces. RA = the sum of resistances in Ω of the earth electrode and the
protective conductor to the exposed conductive parts.
6 Impedance for insulation from earth.
E 7 Insulation monitoring device + surge protection
Id = the current in A causing the protection device to disconnect
within the time as specified in table 41.1 for TT systems
8 Protective device. (see excerpt on page E.8) or within 1 second depending on
the stipulated requirements.

F On a first fault to earth is is not required that an auto-


matic disconnection of the supply takes place provided
that the exposed conductive parts are earthed meeting
the following conditon:
G RA x Id ≤ 50V

where:
RA = the resistance in Ω of the protective conductor of exposed parts
X and that of the earth electrode.
Id = the fault current between line and exposed conductive parts
in A of the first fault taking into account leakage currents and
the total earthing impedance of the installation.

E.10
GuardEon
Required Calculations Disconnection times, the associated current levels and calculated
ZS and Z's values meeting IEC 60364-4-41 clause 411
GuardEon Circuit breakers: PE150 and PE250 with LTM type Trip Units
In order to meet the safety requirements under fault
conditions where disconnection of the supply is ZS value in Ω at a U0 in Volts a.c. of
Magnetic Ia Max.
required it is necessary to verify that the protective setting Im current time 127 220 230 250 400
device will disconnect the supply within the defined (A) (A) (s)
connection times. 60 75.6 0.06 1.680 2.910 3.042 3.307 5.291
150 192 0.06 0.661 1.146 1.198 1.302 2.083
200 240 0.06 0.529 0.917 0.958 1.042 1.667
In all three systems, TT, TN and IT, the use of a overcurrent 250 300 0.06 0.423 0.733 0.767 0.833 1.333
protective device. 320 384 0.06 0.331 0.573 0.599 0.651 1.042

Personnel protection
400 480 0.06 0.265 0.458 0.479 0.521 0.833
500 600 0.06 0.212 0.367 0.383 0.417 0.667
For all three devices the current at which the protective 600 720 0.06 0.176 0.306 0.319 0.347 0.556
device interrupts the supply under fault conditions (Ia) 630 756 0.06 0.168 0.291 0.304 0.331 0.529
650 780 0.06 0.163 0.282 0.295 0.321 0.513
at the interruption time required in table 41.1 and at 1 700 840 0.06 0.151 0.262 0.274 0.298 0.476
and 5 seconds is provided here. Also tabulated is the 750 900 0.06 0.141 0.244 0.256 0.278 0.444
applicable RA value in TT networks when RCDs are used. 800 960 0.06 0.132 0.229 0.240 0.260 0.417
900 1080 0.06 0.118 0.204 0.213 0.231 0.370
Using the most common line to earth voltage U0 the 1000 1200 0.06 0.106 0.183 0.192 0.208 0.333
maximum allowable ZS and Z'S values for a circuit 1250 1500 0.06 0.085 0.147 0.153 0.167 0.267
1500 1800 0.06 0.071 0.122 0.128 0.139 0.222
protected by these devices have been calculated and 1750 2100 0.06 0.060 0.105 0.110 0.119 0.190
indicated in a number of tables included here. 2000 2400 0.06 0.053 0.092 0.096 0.104 0.167
2250 2700 0.06 0.047 0.081 0.085 0.093 0.148
2500 3000 0.06 0.042 0.073 0.077 0.083 0.133
Tables 3000 3600 0.06 0.035 0.061 0.064 0.069 0.111
The table on this page can be used for GuardEon break- 4000 4800 0.04 0.026 0.046 0.048 0.052 0.083
4500 5400 0.04 0.024 0.041 0.043 0.046 0.074
ers with thermal magnetic trip units and the associated 5000 6000 0.04 0.021 0.037 0.038 0.042 0.067
line of add on Residual current devices.
On pages E.12 and E.13 the tables indicate the values
5500
6000
6600
7200
0.04
0.04
0.019
0.018
0.033
0.031
0.035
0.032
0.038
0.035
0.061
0.056 Intro
6500 7800 0.04 0.016 0.028 0.029 0.032 0.051
that can be used for GuardEon circuit breakers with 7000 8400 0.04 0.015 0.026 0.027 0.030 0.048
electronic trip units whilst those on page E.14 contain 7500 9000 0.04 0.014 0.024 0.026 0.028 0.044
the values for electronic devices with an integrated Gf
8000
8500
9600
10200
0.04
0.04
0.013
0.012
0.023
0.022
0.024
0.023
0.026
0.025
0.042
0.039 A
sum protection. 9000 10800 0.04 0.012 0.020 0.021 0.023 0.037
9500 11400 0.04 0.011 0.019 0.020 0.022 0.035
10000 12000 0.04 0.011 0.018 0.019 0.021 0.033
11000
12000
13200
14400
0.04
0.04
0.010
0.009
0.017
0.015
0.017
0.016
0.019
0.017
0.030
0.028 B
12500 15000 0.04 0.008 0.015 0.015 0.017 0.027

E.11
GuardEon
Disconnection times, current levels and calculated ZS & Z'S values for GuardEon Circuit
Breaker PE250 withPremEon S trip unit In= 125A , Ir =125A(1)
Breaker PE150 with PremEon S Trip Unit In=25A, Ir =25A(1) meeting table 41.1. Disconnection time ≤1sec.(TT) or 5sec.(TN)
Short time Ia Max. Short time Ia Max.
setting Ist current time ZS value in Ω at a U0 in Volts a.c. of setting Ist current time ZS value in Ω at a U0 in Volts a.c. of
(x Ir) (A) (s) 127 127 230 250 400 400 (x Ir) (A) (s) 127 220 230 250 400
TN TT TT & TN TT & TN TN TT TT & TN TT & TN TT & TN TT & TN TT & TN
2 56 0.80 2.286 2 278 1.00 0.46 0.79 0.83 0.90 1.44
2.5 69 0.20 1.829 1.829 3.312 3.600 5.760 2.5 347 1.00 0.37 0.63 0.66 0.72 1.15
3 83 0.10 1.524 1.524 2.760 3.000 4.800 3 417 1.00 0.30 0.53 0.55 0.60 0.96
4 111 0.07 1.143 1.143 2.070 2.250 3.600 3.600 4 556 1.00 0.23 0.40 0.41 0.45 0.72
5 139 0.07 0.914 0.914 1.656 1.800 2.880 2.880 5 694 1.00 0.18 0.32 0.33 0.36 0.58
6 167 0.07 0.762 0.762 1.380 1.500 2.400 2.400 6 833 1.00 0.15 0.26 0.28 0.30 0.48
8 222 0.07 0.572 0.572 1.035 1.125 1.800 1.800 8 1111 1.00 0.11 0.20 0.21 0.23 0.36
10 278 0.04 0.457 0.457 0.828 0.900 1.440 1.440 10 1389 1.00 0.09 0.16 0.17 0.18 0.29
12 333 0.07 0.381 0.381 0.690 0.750 1.200 1.200 12 1667 1.00 0.08 0.13 0.14 0.15 0.24
13 361 0.04 0.352 0.352 0.637 0.692 1.108 1.108 13 1806 1.00 0.07 0.12 0.13 0.14 0.22
Application guide

Breaker PE250 withPremEon S trip unit In= 150A , Ir =150A(1)


Breaker PE150 with PremEon S trip unit In= 63A, Ir =32A(1) meeting table 41.1. Disconnection time ≤1sec.(TT) or 5sec.(TN)
Short time Ia Max. Short time Ia Max.
setting Ist current time ZS value in Ω at a U0 in Volts a.c. of setting Ist current time ZS value in Ω at a U0 in Volts a.c. of
(x Ir) (A) (s) 127 127 230 250 400 400 (x Ir) (A) (s) 127 220 230 250 400
TN TT TT & TN TT & TN TN TT TT & TN TT & TN TT & TN TT & TN TT & TN
2 71 0.80 1.786 2 356 1.00 0.36 0.62 0.65 0.70 1.13
2.5 89 0.20 1.429 1.429 2.588 2.813 4.500 2.5 444 1.00 0.29 0.50 0.52 0.56 0.90
3 107 0.10 1.191 1.191 2.156 2.344 3.750 3 533 1.00 0.24 0.41 0.43 0.47 0.75
4 142 0.07 0.893 0.893 1.617 1.758 2.813 2.813 4 711 1.00 0.18 0.31 0.32 0.35 0.56
5 178 0.07 0.714 0.714 1.294 1.406 2.250 2.250 5 889 1.00 0.14 0.25 0.26 0.28 0.45
6 213 0.07 0.595 0.595 1.078 1.172 1.875 1.875 6 1067 1.00 0.12 0.21 0.22 0.23 0.38
8 284 0.07 0.446 0.446 0.809 0.879 1.406 1.406 8 1422 1.00 0.09 0.15 0.16 0.18 0.28
10 356 0.04 0.357 0.357 0.647 0.703 1.125 1.125 10 1778 1.00 0.07 0.12 0.13 0.14 0.23
12 427 0.07 0.298 0.298 0.539 0.586 0.938 0.938 12 2133 1.00 0.06 0.10 0.11 0.12 0.19
13 462 0.04 0.275 0.275 0.498 0.541 0.865 0.865 13 2311 1.00 0.05 0.10 0.10 0.11 0.17

Intro Breaker PE150 with PremEon S trip unit In= 60A , Ir =60A(1)
Disconnection time ≤1sec.(TT) or 5sec.(TN)
Breaker PE250 or PG600 withPremEon S trip unit In= 250A , Ir =250A (1)
Disconnection time ≤1sec.(TT) or 5sec.(TN)
Short time Ia Max. Short time Ia Max.
setting Ist current time ZS value in Ω at a U0 in Volts a.c. of setting Ist current time ZS value in Ω at a U0 in Volts a.c. of
(x Ir) (A) (s) 127 220 230 250 400 (x Ir) (A) (s) 127 220 230 250 400
A 2 140
TT & TN TT & TN TT & TN TT & TN TT & TN
1.00 0.907 1.571 1.643 1.786 2.857 2 556 1.00
TT & TN TT & TN TT & TN TT & TN TT & TN
0.23 0.40 0.41 0.45 0.72
2.5 175 1.00 0.726 1.257 1.314 1.429 2.286 2.5 694 1.00 0.18 0.32 0.33 0.36 0.58
3 210 1.00 0.605 1.048 1.095 1.190 1.905 3 833 1.00 0.15 0.26 0.28 0.30 0.48
4 280 1.00 0.454 0.786 0.821 0.893 1.429 4 1111 1.00 0.11 0.20 0.21 0.23 0.36
B 5
6
350
420
1.00 0.363
1.00 0.302
0.629
0.524
0.657
0.548
0.714
0.595
1.143
0.952
5
6
1389 1.00
1667 1.00 0.08
0.09 0.16
0.13
0.17
0.14
0.18
0.15
0.29
0.24
8 560 1.00 0.227 0.393 0.411 0.446 0.714 8 2222 1.00 0.06 0.10 0.10 0.11 0.18
10 700 1.00 0.181 0.314 0.329 0.357 0.571 10 2778 1.00 0.05 0.08 0.08 0.09 0.14
12 840 1.00 0.151 0.262 0.274 0.298 0.476 12 3333 1.00 0.04 0.07 0.07 0.08 0.12
C 13 910 1.00 0.140 0.242 0.253 0.275
Breaker PE150 with PremEon S type trip unit In= 125A , Ir =125A(1)
0.440 13 3611 1.00 0.04 0.06 0.06 0.07 0.11
Breaker PG600 with PremEon S trip unit In= 600A , Ir =600A(1)
Disconnection time ≤1sec.(TT) or 5sec.(TN) Disconnection time ≤1sec.(TT) or 5sec.(TN)
Short time Ia Max. Short time Ia Max.
setting Ist current time ZS value in Ω at a U0 in Volts a.c. of setting Ist current time ZS value in Ω at a U0 in Volts a.c. of
D (x Ir) (A) (s) 127 220 230 250
TT & TN TT & TN TT & TN TT & TN TT & TN
400 (x Ir) (A) (s) 127 220 230 250 400
TT & TN TT & TN TT & TN TT & TN TT & TN
2 278 1.00 0.457 0.792 0.828 0.900 1.440 2 1400 1.00 0.09 0.16 0.16 0.18 0.29
2.5 347 1.00 0.366 0.634 0.662 0.720 1.152 2.5 1750 1.00 0.07 0.13 0.13 0.14 0.23
3 417 1.00 0.305 0.528 0.552 0.600 0.960 3 2100 1.00 0.06 0.10 0.11 0.12 0.19
E 4
5
556
694
1.00 0.229
1.00 0.183
0.396
0.317
0.414
0.331
0.450
0.360
0.720
0.576
4 2800 1.00 0.05 0.08 0.08 0.09 0.14
5 3500 1.00 0.04 0.06 0.07 0.07 0.11
6 833 1.00 0.152 0.264 0.276 0.300 0.480 6 4200 1.00 0.03 0.05 0.05 0.06 0.10
8 1111 1.00 0.114 0.198 0.207 0.225 0.360 7 4900 1.00 0.03 0.04 0.05 0.05 0.08
10 1389 1.00 0.091 0.158 0.166 0.180 0.288 8 5600 1.00 0.02 0.04 0.04 0.04 0.07
F 12
13
1667 1.00 0.076
1806 1.00 0.070
0.132
0.122
0.138
0.127
0.150
0.138
0.240
0.222
9
10
6300 1.00
7000 1.00
0.02
0.02
0.03
0.03
0.04
0.03
0.04
0.04
0.06
0.06
Breaker PE150 with PremEon S type trip unit In= 150A , Ir =150A(1)
Disconnection time ≤1sec.(TT) or 5sec.(TN) Multiplcation factors for Zs values applicable for LT settings < Ir
G Short time Ia Max.
setting Ist current time ZS value in Ω at a U0 in Volts a.c. of Valid for PremEon S Trip units
(x Ir) (A) (s) 127 220 230 250 400 Setting x In 0.30 0.40 0.50 0.60 0.70 0.80 0.90 0.95
TT & TN TT & TN TT & TN TT & TN TT & TN Factor for ZS 3.33 2.50 2.00 1.67 1.43 1.25 1.11 1.05
2 356 1.00 0.357 0.619 0.647 0.703 1.125
X 2.5
3
444
533
1.00 0.286
1.00 0.238
0.495
0.413
0.518
0.431
0.563
0.469
0.900
0.750 Multiplcation factors for Zs values applicable for LT settings < Ir.
4 711 1.00 0.179 0.309 0.323 0.352 0.563
5 889 1.00 0.143 0.248 0.259 0.281 0.450 For Rating Plugs; Ie = 0.64 x breaker In
6 1067 1.00 0.119 0.206 0.216 0.234 0.375
8 1422 1.00 0.089 0.155 0.162 0.176 0.281 Setting x Ie 0.625 0.650 0.675 0.700 0.725 0.750 0.775 0.800
10 1778 1.00 0.071 0.124 0.129 0.141 0.225 Factor for Zs 2.50 2.40 2.31 2.23 2.16 2.08 2.02 1.95
12 2133 1.00 0.060 0.103 0.108 0.117 0.188 Setting x Ie 0.825 0.850 0.875 0.900 0.925 0.950 0.975 1.000
13 2311 1.00 0.055 0.095 0.100 0.108 0.173 Factor for Zs 1.89 1.84 1.79 1.74 1.69 1.64 1.60 1.56
(1) For other settings please refer to table: For Rating Plugs; Ie = 1 x breaker In
"Multiplication factors for Zs values" on page E.13
(2) In IT systems the lowest Zs setting can also be used for Ist settings Setting x In 0.625 0.650 0.675 0.700 0.725 0.750 0.775 0.800
lower than 8 x Ir Factor for Zs 1.60 1.54 1.48 1.43 1.38 1.33 1.29 1.25
Setting x Ir 0.825 0.850 0.875 0.900 0.925 0.950 0.975 1.000
Factor for Zs 1.21 1.18 1.14 1.11 1.08 1.05 1.03 1.00

E.12
GuardEon

Personnel protection
Intro

Smart, Reliable and Secure C

E.13
GuardEon
Selectivity/Discrimination Fig. 1
UP
Stream
Fig. 1 depicts a typical distribution network.
Here ­outgoing circuits are designed for the current load DOWN
Stream
and the characteristics of the equipment within the UP
circuit. Outgoing circuits that protect a certain area are Stream
feeds other
distribution panels
placed together in panels or form groups within panels.
Typically this group of circuits is protected by a second,
similar device, the characteristics of which are
­determined in the same manner. This system can be DOWN
extended to a multiple level distribution network. Stream

In case of a fault it is necessary that the device ­nearest


Application guide

to the fault reacts while all others remain closed. feeds other circuits
ON fault “F”: C3 reacts only: 1 circuit without power
This capability is called discrimination (UK) or selectivity C2 + C3 react: Multiple circuits without power
C1 + C2 + C3 react: Multiple panels containing
(USA and Europe). If this requirement is not met, a fault Multiple circuits without power
(F) in one arm of the distribution ­system will cause a
number of upstream protection devices wired in series to
trip. Thus a minor fault in a socket outlet of a circuit can
cause whole floors, buildings or building complexes to be
cut off from the power ­supply.

GuardEon breakers are specifically designed to


­discriminate. By introducing GuardEon. GE sets a new
­standard in circuit breakers by offering total ­selectivity for
Intro all normally proportioned distribution systems.

EN 60947-2 amendment 1, app. A defines under


“Coordination” that discrimination/selectivity may be
A partial up to a pre-defined current limit (Is).
Discrimination is considered total when the current limit
is equal to the rated short-circuit breaking ­capacity (Icu
or Ics) of the downstream device.
B Discrimination/Selectivity is determined by ­comparing Ird Iru
Fig. 2 10000
the time it takes an upstream device to react at a 120
100
80

­specific current value and - again - ­comparing this to 60


50
40
tripband downstream device

C
30
the time it takes a downstream device to clear the fault 20
1000 tripband upstream device

at the same current level. (see Fig. 2) The comparison of 10


8
6
5
these two time spans can be used to define whether 4
3
2
discrimination is present or not. 100

D
1

We have simplified this comparison by applying a


­multiplication factor between downstream and
Seconds
Minutes

10
upstream devices. With the values indicated in the table
we can guarantee discrimination.
E (see page E.17) 1
Imd Imu
Trip time

F Selectivity Plus
0,1

Ird:
x Setting current I (Amp)
Overload or LT setting downstream device
Iru: Overload or LT setting upstream device
Imd: Magnetic or ST setting downstream device
Imu: Magnetic or ST setting upstream device
GuardEon circuit breakers limit the electrical energy
G and peak current of a short-circuit event extremely
effectively and limit the time span involved to the utter
minimum. Fig. 3 Trip time overlay
The downstream breaker limits the magnitude of the
X fault so effectivley that the upstream, time delayed,
0,01
GuardEon breaker is only exposed to a relativley low
level short-circuit current that does not trip the breaker. Msec.
Fig.3 depicts this three dimensional selectivity technique
that allows for the selective interruption of a short-circuit 0,005

event making use of all the events' parameters Current,


Energy and Time.
2x105
0
5000 3x105
1x104
1,5x104
2x104
(Ym, Xm, Zmsec), (Y3m, X3m, Z3msec)

E.14
GuardEon
Back-up protection
One of the operational requirements for a protective
device is that its rated short-circuit breaking capacity Icu
or Ics is either equal or greater than the ­prospective
short-circuit current at the point where it is installed.
EN 60384 defines one exception to this in clause 434:

The upstream device must posses the necessary rated


short-circuit breaking capacity at its point of installation.
The upstream device must coordinate with the
­downstream device in a manner that will limit the energy

Application guide
and short-circuit values to levels that the downstream
device can handle.

Use of current limitation


Installing an upstream device that limits the ­prospective
short-circuit values will enable the user to place a
­downstream device with a lower breaking capacity.
Intro
The ­coordination between the two devices allows
Crest value and
­excellent breaking capacity at a low cost. waveform without
current limitation. A
GuardEon Crest value and
waveform with
The GuardEon rotating dual contact ­configuration limits
the energy and current values of prospective faults to
current limitation.
B
extremely low values. This key design feature allows the
use of cost-effective ­downstream devices while main- Effect of a current limiting device
taining overall system protection.
Back-up protection is inherently „unselective“ or ­­
on a short-circuit in an AC network.
C
„non-discriminating“. That means that the upstream
device must react first in order to protect the
­downstream device. However, the GuardEon devices are D
so ­current limiting that the current and energy ­values
­present in the circuit do not trip the upstream breaker.
Please refer to the details on „Selectivity Plus“ for a
description of this technique.
E
The tables B1 and B2 are in complete accordance with
the EN 60947-2 requirements and have been ­verified F
through experiment where necessary. They provide
data for the GuardEon breaker and the other
GE Industrial Systems product lines.
The values are only applicable for the devices ­mentioned. G

E.15
GuardEon
Protection of motor circuits

General
In a circuit that provides power to a motor a ­number
of protective and control devices are ­normally
­present. The combination of these devices must be Isolator
coordinated to ensure the ­efficiency and an optimal
protection of the motor. Here, the protection of such
circuits strongly depends on the operational
­requirements, as the application for which the motor Short circuit protection
is used, the required starting frequency, the required
Application guide

service level and the applicable safety standards.


Overload protection

extra
Protection of the electrical circuit Control functions
The motor circuit must provide the following phase
­functionality: loss
Cables
• Isolate the circuit from the network for ­maintenance. blocked
• Protect against short-circuits in the equipment, rotor
the starter and the cables within the circuit. Motor thermal
memory
• Protect against overloads in the equipment,
the starter and the cables within the circuit.
• Protect against faults specific to the motor within it's
application.
Intro Control of the motor in question, this covering ­starting,
Category Load type Contactor usage
­stopping, speed control etc.
AC1 Non Inductive motors Energization
A Standards
The requirements for circuits supplying a motor, in
AC2 Slip ring motors Starting
Switching off whilst running
Regenerative breaking
­general called "motor starters", can be found in the Inching
IEC 60947-4-1. To define the components for ­isolation, AC3 Squirrel-cage motors Energization
B overload and short-circuit protection the following
AC4 Squirrel-cage motors
Switching off whilst running
Starting
­elements must be defined: (cos phi = 0.45 ≤ 100A) Switching off whilst running
• Depending on the type of electrical motor and it’s (cos phi = 0.35 > 100A) Regenerative breaking
operational requirements, four motor utilization Plugging
C ­categories have been defined. These have an impact
Inching

on the characteristics of the control ­element within


the circuit. These so called AC classes are depicted in Required tripping times at
D the table on the right. Trip class 1.2 x In 1.5 x In 7.2 x In
• The required trip curve class of the overload
10A t < 2 hours t < 2 min. 2 ≤ t ≤ 10 sec.
­protection, this depending on the motor ­application, 10 t < 2 hours t < 4 min. 4 ≤ t ≤ 10 sec.
the classes 10A, 10, 20 and 30 are normally used, 20 t < 2 hours t < 8 min. 6 ≤ t ≤ 20 sec.
E the requirements for which are indicated in the table. 30 t < 2 hours t < 12 min. 9 ≤ t ≤ 30 sec.

• Isolation and safety during maintenance. Use of


F the GuardEon breaker here provides an
­enhancement of the present standard requirement
for POSITIVE OFF adding in a POSITIVE ON ­indication.

E.16
GuardEon
Coordination type 2 test sequence
Coordination
The standards require tests to define the Motor current Ie (AC3) Test with current "r"
­coordination between the devices within the motor
starter. Depending on the state of the components 15 < Ie ≤ 60A 3 kA
after the test two coordination classes 1 and 2 60 < Ie ≤ 125A 5 kA
have been defined. 125 < Ie ≤ 315A 10 kA
315 < Ie ≤ 600A 18 kA

Protection of motor circuits


The unique properties of the GuardEon breaker allow • After this test the original characterstics of the contactor and ­
GE to offer solutions meeting the highest ­standards. thermal relay MUST remain unchanged.
• After this test the short-circuit protection must trip within 10 ms
For this reason all tables published here only refer to at a fault current ≥ 15 x In.
coordination type 2.

This entails that the GE equipment meets the Short-circuit test


­following standards
• No or minor weldings of the contactors after ­testing; This value which is generally ≤ 50kA is used to check the coordination
contact separation is simple and easy of the devices used in the motor starter circuit.
After a test with this current the following conditions must be met:
• The switchgear and controlgear are fully ­operational • No or minor weldings of the contactors after testing; contact
after the tests indicated here. separation is simple and easy
• The switchgear and controlgear are fully operational after the test.

Solutions with the GuardEon breaker


Motor starters are compiled with a number of
GE components. This is to offer the required
­functionality of the motor starter circuit and to
allow a choice in the execution thereof.
Intro
Option 1 Option 2

Electronic circuit A
Magnetic only breaker as the
circuit breaker as the short-circuit and
TM
Record Plus
Circuit Breaker
FE250
Ui: 690V NEMA AB1 3ph
240V 100kA
480V 50kA

short-circuit Overload protection


Ue (50/60Hz) Icu/Ics 600V 25kA

B
230/240V 65kA Ue (DC) Icu/Ics
400/415V 36kA
440V 25kA 250V 2p 50kA
500V 18kA 500V 3p 50kA
690V 10kA In=Ithe: 250A 40°C
GPC2640000P457
BS CEI JIS UNE VDE Catalogue Number

protection device. device.


IEC60947-2 FEN306F250KF-C
GB14048.2 431715
Cat.A
S

A010847

Contactor for control C


purposes.
Contactor for control
purposes.
Separate thermal relay D
for class 10 or
class 30 as overload
protection.
E

E.17
Smart, Reliable and Secure
GuardEon

The circuit breaker Intro

Order codes A

Trip units B

Components and accessories C

Technical data D

F.2 E frame - Factory connection scheme on plug-in & draw-out


Application guide E
F.3 G frame - Factory connection scheme on plug-in & draw-out
Wiring diagrams F

Dimensions G

Numerical Index X

F.1
GuardEon
Recommended wiring diagrams

E frame - Factory connection scheme on plug-in & draw-out

M
Wiring diagrams

Intro

C
X... 1 2 3 4 5 6 7 8 Y... 1 2 3 4 5 6 7 8

D ... ... ... ... ... ...


C1
SHT
C2 ... ... ... ...
E or 1 or or

... ...
D1 A1 A2 A4 2

F UVR ... ...


D2
Breaker Electrical Breaker Breaker
M operator

G or

X ... ... ... ...

... ...
Rotary handle
LH Aux. Contacts - 0-2 max
M FABAM - mechanism
RH Aux. Contacts - 0-2 max
FASHT /FAUVR
T FABAT - trip

F.2
GuardEon

G frame - Factory connection scheme on plug-in & draw-out

Wiring diagrams
M
T

Intro

C
X... 1 2 3 4 5 6 7 8 W...1 2 3 4 5 6 7 8 Y... 1 2 3 4 5 6 7 8
D
C1
... ... ... ... ... ... ... ... ... ... ...
SHT
C2 ... ... ... ... ... ... ...
or 1 or or E
... ...
D1 A1 A2 A4 2
UVR ... ... F
D2
Breaker Electrical Breaker Breaker Breaker RCD
M operator

or G

... ... ... ... X


... ...
LH Aux. Contacts - 0-2 max
Rotary handle
RH Aux. Contacts - 0-2 max
M FABAM - mechanism
T FABAT - trip
FASHT /FAUVR

F.3
Smart, Reliable and Secure
GuardEon

The circuit breaker Intro

Order codes A

Trip units B

Components and accessories C

Technical data D

Application guide E

G.2 PE breakers Wiring diagrams F


G.8 PG breakers
Dimensions G

Numerical Index X

G.1
GuardEon
Dimensional Drawings

Breakers - PE150/250, 2, 3 and 4 pole, front connected


Breakers - PE160/250, 2, 3 and 3 pole, front connected

104.5 139.5 111


(4.1) (5.5) (4.4)
91 91 94
(3.6) (3.6) (3.7)
35 35 35 35 35 22
(1.4) (1.4) (1.4) (1.4) (1.4) (0.8)
35 35 35 3
(1.4) 10 (1.4) (1.4) (0.1)
(0.4)
Ø 9.5
(0.4)
Dimensions

Ø 55.7
(2.2)

156
(6.1)
91 91
(3.6) (3.6)
127 139 127 140 170
(5.1) (5.5) (5) (5.5) (6.7)

156
(6.1)

Intro 3
3
(0.1)
(0.1)

18 35 18 35 35 3
(0.7) (1.4) (0.7) (1.4) (1.4) (0.1)

A 85.5
(3.4)

B
Breakers with phase separators - PE160/250, 2, 3 and 4 pole, front connected
C Breakers with phase separators - PE150/250, 2, 3 and 4 pole, front connected

D
111
6 (4.4)
35 (0.2)
(1.4) 94
6 35 35 (3.7)
(0.2)

E
(1.4) (1.4)

120 120
(4.7) (4.7)

F
1
(0.04)

G 127
(5)
127
(5)
410
(16.1)

3 3
(0.1) (0.1)

X
120 120
(4.7) (4.7)

35 35 35 72.5
(2.9)
(1.4) (1.4) (1.4)

G.2
GuardEon
Dimensional Drawings
Breakers with phase separators - PE160/250, 2, 3 and 4 pole, rear connected

Breakers with phase separators - PE150/250, 2, 3 and 4 pole, rear connected

35 6 111
(1.4) (0.2) (4.4)
6 35 35 94
(0.2) (1.4) (1.4) (3.7)

67 67 73
(2.6) (2.6) (2.9)

PE breakers
127 127 304
(5) (5) (12)
52
3 3 (2.1)
(0.1) (0.1)

67 67 73
(2.6) (2.6) (2.9)

35 35 35 126
Intro
(1.4) (1.4) (1.4) (4.9)

Breakers Breakers
- PE150/250, 2,3 3andand
- PE160/250, 2, 4 pole,4front
pole, front
connected connected
with lugs with lugs C

35
(1.4)
35
(1.4)
111
E
35 35 35 (4.4)
35 (1.4) (1.4) (1.4)
(1.4) 94
35 35 (3.7)
(1.4) (1.4)
19 17

F
(0.8) (0.7)

127
208
G
127 (8.2)
(5)
(5)

(0.1)
3
3
(0.1) X
19 17
(0.8) (0.7)

35 13.5 35 35 30 51
(1.4) (0.5) (1.4) (1.4) (1.2) (2)
133.3
13.5 (5)
(0.5)
98
(3.9)

G.3
GuardEon
Dimensional Drawings

Breakers - PE160/250, 2, 3 and 4 pole, front connected with extended angle 45°
Breakers - PE150/250, 2, 3 and 4 pole, front connected with extended angle 45°

104.5
(4.1)
91
(3.6)
111
35 35 (4.4)
(1.4) (1.4) 35 35 35
(1.4) (1.4) (1.4) 94
35 (3.7)
(1.4) 35 35 26
(1.4) (1.4) (1)

3 .1)
(0
(0 0
2
)
.8
Ø9
(0.4)
Dimensions

12 .5)
(0
SCALE 2:1
127 127
(5) 230 (5) 230
(9.1) (9.1)

3 3 3.5
(0.1) (0.1) (0.1)

Intro R6
(0.2)

4 .2)
(0
35 35 35
(1.4) (1.4) (1.4) 45°
17 17 17 17 17

A
(0.7) (0.7) (0.7) (0.7) (0.7)
18 18 18 18 18
(0.7) (0.7) (0.7) (0.7) (0.7)
88 123
(3.5) (4.8)

C Breakers - PE150/250, 2, 3 and 4 pole, front connected with extended angle 90°

Breakers - PE160/250, 2, 3 and 4 pole, front connected with extended angle 90°

D 35
(1.4)
35
(1.4) 35
(1.4)
35
(1.4)
35
(1.4)
35 35 35 4
(1.4) (0.2)
(1.4) (1.4)

18
(0.7)

F
205 127 205
127 (8,1) (5) (8,1)
(5)

G 10.2
(0.4)

3 3

X
(0.1) (0.1)

17
(0.7)

35 35 35 36
(1.4) (1.4) (1.4) (1.4)
17 17 17 17 17 94
(0.7) (0.7) (0.7) (0.7) (0.7) (3.7)
18 18
(0.7) (0.7) 18 18 18 111
(0.7) (0.7) (0.7) (4.4)
88
(3.5) 123
(4.8)

3 20 Ø9 3
(0.4) 20 Ø9
(0.1) (0.8) (0.1) (0.4)
(0.8)

12
(0.5) 12
(0.5)

G.4
GuardEon
Dimensional Drawings

Breakers - PE150/250, 2, 3 and 4 pole, front connected with heightened extenders

Breakers - PE160/250, 2, 3 and 4 pole, front connected with heightened extenders

35 35 35
35 35 (1.4) (1.4) (1.4)
(1.4) (1.4)
35 35 35 48 4
(1.4) Ø9 (1.4) (1.4) (1.9) (0.2)
Ø9 (0.4)
(0.4)

29
(1.1)

4.5
(0.2)

PE breakers
127 127
(5) 211 229 (5) 211 229
(8.3) (9) (8.3) (9)

3 3
(0.1)
(0.1)

29
(1.1)
Intro
4
35 35 35 (0.2)
(1.4) (1.4) (1.4)
48
18 18 17 17 17 (1.9)
(0.7) (0.7) (0.7) (0.7) (0.7)

A
94
18 18 18 18 18 (3.7)
(0.7) (0.7) (0.7) (0.7) (0.7) 111
123 (4.4)
88 (4.8)
(3.5)

Breakers - PE150/250, 2, 3 and 4 pole, front connected with 90° twisted extenders
Breakers - PE160/250, 2, 3 and 4 pole, front connected with 90° twisted extenders C
35

D
(1.4)

4
(0.2) 4 35 35 18 Ø9
(0.2) (1.4) (1.4) (0.7) (0.4)

Twisted 90° Twisted 90°

F
127 241 223
(5)
127 (9.5) (8.8)
(5)

G
3

X
(0.1) 3
(0.1)

35 35 35 14.8
(1.4) (1.4) (1.4) (0.6)
94
31 31 31 31 31 (3.7)
(1.2) (1.2) (1.2) (1.2) (1.2) 111
74 (4.4)
(2.9) 109
(4.3)

G.5
GuardEon
Dimensional Drawings

Breakers - PE150/250, 2, 3 and 4 pole, front connected with flat extenders

Breakers - PE160/250, 2, 3 and 4 pole, front connected with flat extenders

35 35 35 35 35 111
(1.4) (1.4) (1.4) (1.4) (1.4) (4.4)
94
35 35 35 (3.7)
(1.4) 8xØ9 (1.4) (1.4) 4
6xØ9 (0.4) (0.2)
(0.4)
Dimensions

127 211 229


(5) 211 229
(8.3) (9) (8.3) (9)
127
(5)

3 3
(0,1) (0,1)

Intro
35 35 35
(1.4) (1.4) (1.4) 22
17 17 17 17 17 (0.9)
(0.7) (0.7) (0.7) (0.7) (0.7)

A
18 18 18 18 18
(0.7) (0.7) (0.7) (0.7) (0.7)
123
(4.8)
88
(3.5)

C Breakers - PE150/250, 2, 3 and 4 pole, front connected with flat spreaders

Breakers - PE160/250, 2, 3 and 4 pole, front connected with flat spreaders

D
111
45 45 45 45 45 (4.4)
(1.8) (1.8) (1.8) (1.8) (1.8)
94
(3.7)
35 35 35 4
8xØ9

E
6xØ9 (1.4) (1.4) (1.4) (0.2)
(0.4)
(0.4)

G 127
(5) 211 229
(8.3) (9) 127
(5)
211 229
(8.3) (9)

X
3 3
(0.1) (0.1)

32°
35 35 35 22
(1.4) (1.4) (1.4) (0.9)
27 27 27 27 27
(1.1) (1.1) (1.1) (1.1) (1.1)
18 18 18 18 18 18
(0.7) (0.7) (0.7) (0.7) (0.7) (0.7)

153
108 (6.0)
(4.3)

G.6
GuardEon
Dimensional Drawings

Breakers - PE150/250, 2, 3 and 4 pole, front connected, terminal shields


Breakers - PE160/250, 2, 3 and 4 pole, front connected, terminal shields

111
104.5 139.5 (4.4)
(4.1) (5.5)

94
35 35 35 (3.7)
(1.4) (1.4) (1.4)

PE breakers
127
(5)
172 172 127
(6.8) (6.8) (5)

3
(0.1) 3
(0.1)

35
(1.4)
35
(1.4)
35
(1.4)
85.5
(3.4)
Intro

G.7
GuardEon
Dimensional Drawings

Frame-G - Breakers – PG630, 2, 3 and 4 pole, front connected


Breakers - PG600 - 2, 3 and 4 pole front connected

138.9 160.2
183.7 (6.31)
(5.47) (7.23)
127.2
122.1 (5.01)
(4.81) 45 45 45 21.5
45 45 (1.8) (1.8) (1.8) (0.85)
(1.8) (1.8) 6
(0.24)
Dimensions

Ø90.9 90.9
(3.6) (3.6)

122.1 122
(4.81) (4.8)
229
228.6 (9) 261.9
(9) (10.31)

Intro 15 15
30
(1.2)
30
(1.2)
21.4
(0.84)
111.5
(0.6) (0.6) (4.39)
15 15
30 30 (0.6) (0.6)
(1.2) (1.2) 30 30
(1.2) (1.2)

A
120 165
(4.7) (6.5)

B
Frame-G - Breaker 2P, 3P and 4P with Extenders Std type
C Breakers - PG600, 2, 3 and 4 pole with extenders standard type

D
45 45 Ø10,4 45 45 45 8
(0.5) (1.8) (1.8) (0.4)
(1.8) (1.8) (1.8) (0.3)

F
341
313 (13.4)

G
(12.3) 313 341
(12.3) (13.4)

15 15 15 21.4
15 15 (0.6) (0.6) (0.6) (0.8)
(0.6) (0.6)
30 30 30 30 30 30
(1.2) (1.2) (1.2) (1.2) (1.2) (1.2)

120 165
(4.7) (6.5)

G.8
GuardEon
Dimensional Drawings

e-G - Breaker-2P, 3P and 4P with Spreaders


Breakers - PG600, 2, 3 and 4 pole with spreaders

Ø11.8 52.5 52.5


(0.5) (2.1) (2.1) Ø10.4
52.5 52.5 52.5 8
(0.4)
(2.1) (2.1) (2.1) (0.3)

PG breakers
341
(13.4)
313
(12.3) 313 341
(12.3) (13.4)

Intro
22.5 22.5 22.5 22.5 22.5 (21.4)
(0.9) (0.9) (0.9) (0.9) (0.9)

A
(0.8)
30 30 30
(1.2) (1.2) (1.2) 30 30 30
(1.2) (1.2) (1.2)
135
(5.3)
187.5
(7.4)

B
e-G - Breaker-2P, 3P and 4P with Extenders Heightened type

Breakers - PG600, 2, 3 and 4 pole with heightened extenders C

D
45 45
(0.5) (1.8) (1.8) Ø13
45 45 45 8
(0.5)

E
(1.8) (1.8) (1.8) (0.3)

40
(1.6)

14.5
(0.6)

F
313
(12.3)

345
(13.6)
313
(12.3)
345
(13.6) G

X
40
(0.6)

15 15 15 15 15 8
(0.6) (0.6) (0.6) (0.6) (0.6) (0.3)
30 30 30
(1.2) (1.2) (1.2) 30 30 30
(1.2) (1.2) (1.2)
120
(4.7)
165
(6.5)

G.9
GuardEon
Dimensional Drawings

Frame-G - Breaker-2P, 3P and 4P with Extend Twisted 90º

Breakers - PG600, 2, 3 and 4 pole with 90° twisted extenders

8 Ø13
8 30
(0.3) (0.5)
(0.3) (1.2)
Dimensions

345 313
(13.6) (12.3)

Intro
37 37 37 10.5
37 37 (1.5) (1.5) (1.5) (0.4)
(1.5) (1.5)

A 98
(3.9)
143
(5.6)

G.10
GuardEon

The circuit breaker Intro

Order codes A

Trip units B

Components and accessories C

Technical data D

Application guide E

Wiring diagrams F

Dimensions G
X.2 By catalogue number
Numerical Index X

X.1
GuardEon
Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page
F… P1NRDV C.4 PEAB2ATSH0125 A.16 PEAB4ATAM0150 A.21 PEAC2ATSF0060 A.14 PEAC4ATAL0125 A.17
FABAM01 C.2 P1NRF C.4 PEAB2ATSH0150 A.20 PEAB4ATEJ0025 A.13 PEAC2ATSF0125 A.16 PEAC4ATAL0150 A.21
FABAM10 C.2 P1NRFV C.4 PEAB2ATTN0020 A.6 PEAB4ATEJ0060 A.15 PEAC2ATSF0150 A.20 PEAC4ATAM0025 A.13
FABAT01 C.2 P1NRY C.4 PEAB2ATTN0025 A.6 PEAB4ATEJ0125 A.17 PEAC2ATSH0025 A.12 PEAC4ATAM0060 A.15
FABAT10 C.2 P1NRYV C.4 PEAB2ATTN0030 A.6 PEAB4ATEJ0150 A.21 PEAC2ATSH0060 A.14 PEAC4ATAM0125 A.17
FAPF8 C.7 P1NRZ C.4 PEAB2ATTN0040 A.6 PEAB4ATEK0025 A.13 PEAC2ATSH0125 A.16 PEAC4ATAM0150 A.21
FAPFM C.7 P1NRZV C.4 PEAB2ATTN0050 A.6 PEAB4ATEK0060 A.15 PEAC2ATSH0150 A.20 PEAC4ATEJ0025 A.13
FAPIP C.8 P21PE C.6 PEAB2ATTN0060 A.6 PEAB4ATEK0125 A.17 PEAC2ATTN0020 A.6 PEAC4ATEJ0060 A.15
FAPM8 C.7 P21PF C.6 PEAB2ATTR0070 A.6 PEAB4ATEK0150 A.21 PEAC2ATTN0025 A.6 PEAC4ATEJ0125 A.17
FAPPS C.7 P2LHK C.5 PEAB2ATTR0080 A.6 PEAB4ATEL0025 A.13 PEAC2ATTN0030 A.6 PEAC4ATEJ0150 A.21
FAS01L C.2 P2NBM C.6 PEAB2ATTR0090 A.6 PEAB4ATEL0060 A.15 PEAC2ATTN0040 A.6 PEAC4ATEK0025 A.13
FAS01R C.2 P2NFP C.5 PEAB2ATTR0100 A.6 PEAB4ATEL0125 A.17 PEAC2ATTN0050 A.6 PEAC4ATEK0060 A.15
FAS10L C.2 P2NFT C.5 PEAB2ATTR0110 A.6 PEAB4ATEL0150 A.21 PEAC2ATTN0060 A.6 PEAC4ATEK0125 A.17
FAS10R C.2 P2NRC C.4 PEAB2ATTR0125 A.6 PEAB4ATEM0025 A.13 PEAC2ATTR0070 A.6 PEAC4ATEK0150 A.21
FAS30W C.8 P2NRCV C.4 PEAB2ATTR0150 A.6 PEAB4ATEM0060 A.15 PEAC2ATTR0080 A.6 PEAC4ATEL0025 A.13
FAS33W C.8 P2NRD C.4 PEAB3ATAJ0025 A.12 PEAB4ATEM0125 A.17 PEAC2ATTR0090 A.6 PEAC4ATEL0060 A.15
FASHTB C.3 P2NRDV C.4 PEAB3ATAJ0060 A.14 PEAB4ATEM0150 A.21 PEAC2ATTR0100 A.6 PEAC4ATEL0125 A.17
FASHTD C.3 P2NRF C.4 PEAB3ATAJ0125 A.16 PEAB4ATGR0100 A.8 PEAC2ATTR0110 A.6 PEAC4ATEL0150 A.21
Numerical index

FASHTF C.3 P2NRFV C.4 PEAB3ATAJ0150 A.20 PEAB4ATGR0110 A.8 PEAC2ATTR0125 A.6 PEAC4ATEM0025 A.13
FASHTH C.3 P2NRY C.4 PEAB3ATAK0025 A.12 PEAB4ATGR0125 A.8 PEAC2ATTR0150 A.6 PEAC4ATEM0060 A.15
FASHTJ C.3 P2NRYV C.4 PEAB3ATAK0060 A.14 PEAB4ATGR0150 A.8 PEAC3ATAJ0025 A.12 PEAC4ATEM0125 A.17
FASHTN C.3 P2NRZ C.4 PEAB3ATAK0125 A.16 PEAB4ATSB0025 A.13 PEAC3ATAJ0060 A.14 PEAC4ATEM0150 A.21
FASHTU C.3 P2NRZV C.4 PEAB3ATAK0150 A.20 PEAB4ATSB0060 A.15 PEAC3ATAJ0125 A.16 PEAC4ATGR0100 A.8
FAUVDN C.3 P2PR C.6 PEAB3ATAL0025 A.12 PEAB4ATSB0125 A.17 PEAC3ATAJ0150 A.20 PEAC4ATGR0110 A.8
FAUVR8 C.3 PA… PEAB3ATAL0060 A.14 PEAB4ATSB0150 A.21 PEAC3ATAK0025 A.12 PEAC4ATGR0125 A.8
FAUVRB C.3 PABAM11 C.2 PEAB3ATAL0125 A.16 PEAB4ATSE0025 A.13 PEAC3ATAK0060 A.14 PEAC4ATGR0150 A.8
FAUVRD C.3 PABAT11 C.2 PEAB3ATAL0150 A.20 PEAB4ATSE0060 A.15 PEAC3ATAK0125 A.16 PEAC4ATSB0025 A.13
FAUVRF C.3 PAPPG C.7 PEAB3ATAM0025 A.12 PEAB4ATSE0125 A.17 PEAC3ATAK0150 A.20 PEAC4ATSB0060 A.15
FAUVRH C.3 PAS11 C.2 PEAB3ATAM0060 A.14 PEAB4ATSE0150 A.21 PEAC3ATAL0025 A.12 PEAC4ATSB0125 A.17
FAUVRJ C.3 PAS33W C.8 PEAB3ATAM0125 A.16 PEAB4ATSF0025 A.13 PEAC3ATAL0060 A.14 PEAC4ATSB0150 A.21
FAUVRN C.3 PC… PEAB3ATAM0150 A.20 PEAB4ATSF0060 A.15 PEAC3ATAL0125 A.16 PEAC4ATSE0025 A.13
FAUVRU C.3 PCALK217LV C.9 PEAB3ATEJ0025 A.12 PEAB4ATSF0125 A.17 PEAC3ATAL0150 A.20 PEAC4ATSE0060 A.15
FD1PR C.6 PCALK315LV C.9 PEAB3ATEJ0060 A.14 PEAB4ATSF0150 A.21 PEAC3ATAM0025 A.12 PEAC4ATSE0125 A.17
FEBE43 C.8 PCALK316LV C.9 PEAB3ATEJ0125 A.16 PEAB4ATSH0025 A.13 PEAC3ATAM0060 A.14 PEAC4ATSE0150 A.21
FEBE44 C.8 PCALK317LV C.9 PEAB3ATEJ0150 A.20 PEAB4ATSH0060 A.15 PEAC3ATAM0125 A.16 PEAC4ATSF0025 A.13
FEBE93 C.8 PCALK415LV C.9 PEAB3ATEK0025 A.12 PEAB4ATSH0125 A.17 PEAC3ATAM0150 A.20 PEAC4ATSF0060 A.15
Intro FEBE94
FEBEA3
C.8
C.8
PCALK416LV
PCALK417LV
C.9
C.9
PEAB3ATEK0060
PEAB3ATEK0125
A.14
A.16
PEAB4ATSH0150
PEAB4ATTN0020
A.21
A.8
PEAC3ATEJ0025
PEAC3ATEJ0060
A.12
A.14
PEAC4ATSF0125
PEAC4ATSF0150
A.17
A.21
FEBEA4 C.8 PCAT50 B.22 PEAB3ATEK0150 A.20 PEAB4ATTN0025 A.8 PEAC3ATEJ0125 A.16 PEAC4ATSH0025 A.13
FEBEH3 C.8 PCAT51 B.22 PEAB3ATEL0025 A.12 PEAB4ATTN0030 A.8 PEAC3ATEJ0150 A.20 PEAC4ATSH0060 A.15
FEBEH4 C.8 PCAT53 B.22 PEAB3ATEL0060 A.14 PEAB4ATTN0040 A.8 PEAC3ATEK0025 A.12 PEAC4ATSH0125 A.17
A FEBES3
FEBES4
C.8
C.8
PCOMMOD
PE…
B.22 PEAB3ATEL0125
PEAB3ATEL0150
A.16
A.20
PEAB4ATTN0050
PEAB4ATTN0060
A.8
A.8
PEAC3ATEK0060
PEAC3ATEK0125
A.14
A.16
PEAC4ATSH0150
PEAC4ATTN0020
A.21
A.8
FEBRC3 C.9 PE1PE C.6 PEAB3ATEM0025 A.12 PEAB4ATTR0070 A.8 PEAC3ATEK0150 A.20 PEAC4ATTN0025 A.8
FEBRC4 C.9 PE1PF C.6 PEAB3ATEM0060 A.14 PEAB4ATTR0080 A.8 PEAC3ATEL0025 A.12 PEAC4ATTN0030 A.8
FEBRCS3 C.9 PEAB2ATAJ0025 A.12 PEAB3ATEM0125 A.16 PEAB4ATTR0090 A.8 PEAC3ATEL0060 A.14 PEAC4ATTN0040 A.8
FEBRCS4 C.9 PEAB2ATAJ0060 PEAB3ATEM0150 A.20 PEAB4ATTR0100 A.8 PEAC3ATEL0125 A.16 PEAC4ATTN0050 A.8
B FEBSS3
FEBSS4
C.8
C.8
PEAB2ATAJ0125
PEAB2ATAJ0150
A.14
A.16
A.20
PEAB3ATGR0100
PEAB3ATGR0110
A.7
A.7
PEAB4ATTR0110
PEAB4ATTR0125
A.8
A.8
PEAC3ATEL0150
PEAC3ATEM0025
A.20
A.12
PEAC4ATTN0060
PEAC4ATTR0070
A.8
A.8
FEDDF3 C.7 PEAB2ATAK0025 A.12 PEAB3ATGR0125 A.7 PEAB4ATTR0150 A.8 PEAC3ATEM0060 A.14 PEAC4ATTR0080 A.8
FEDDF4 C.7 PEAB2ATAK0060 A.14 PEAB3ATGR0150 A.7 PEAC2ATAJ0025 A.12 PEAC3ATEM0125 A.16 PEAC4ATTR0090 A.8
FEDFF3 C.7 PEAB2ATAK0125 A.16 PEAB3ATSB0025 A.12 PEAC2ATAJ0060 A.14 PEAC3ATEM0150 A.20 PEAC4ATTR0100 A.8
C FEDFF4
FEDMP3
C.7
C.7
PEAB2ATAK0150
PEAB2ATAL0025
A.20
A.12
PEAB3ATSB0060
PEAB3ATSB0125
A.14
A.16
PEAC2ATAJ0125
PEAC2ATAJ0150
A.16
A.20
PEAC3ATGR0100
PEAC3ATGR0110
A.7
A.7
PEAC4ATTR0110
PEAC4ATTR0125
A.8
A.8
FEDMP4 C.7 PEAB2ATAL0060 A.14 PEAB3ATSB0150 A.20 PEAC2ATAK0025 A.12 PEAC3ATGR0125 A.7 PEAC4ATTR0150 A.8
FEGS0025 B.23 PEAB2ATAL0125 A.16 PEAB3ATSE0025 A.12 PEAC2ATAK0060 A.14 PEAC3ATGR0150 A.7 PEAE2ATAJ0025 A.12
FEGS0063 B.23 PEAB2ATAL0150 A.20 PEAB3ATSE0060 A.14 PEAC2ATAK0125 A.16 PEAC3ATSB0025 A.12 PEAE2ATAJ0060 A.14
D FEGS0125
FEGS0160
B.23
B.23
PEAB2ATAM0025
PEAB2ATAM0060
A.12
A.14
PEAB3ATSE0125
PEAB3ATSE0150
A.16
A.20
PEAC2ATAK0150
PEAC2ATAL0025
A.20
A.12
PEAC3ATSB0060
PEAC3ATSB0125
A.14
A.16
PEAE2ATAJ0125
PEAE2ATAJ0150
A.16
A.20
FEGS0250 B.23 PEAB2ATAM0125 A.16 PEAB3ATSF0025 A.12 PEAC2ATAL0060 A.14 PEAC3ATSB0150 A.20 PEAE2ATAK0025 A.12
FEJP C.10 PEAB2ATAM0150 A.20 PEAB3ATSF0060 A.14 PEAC2ATAL0125 A.16 PEAC3ATSE0025 A.12 PEAE2ATAK0060 A.14
FETCA1323 C.9 PEAB2ATEJ0025 A.12 PEAB3ATSF0125 A.16 PEAC2ATAL0150 A.20 PEAC3ATSE0060 A.14 PEAE2ATAK0125 A.16
FETCA1423 C.9 PEAB2ATEJ0060 A.14 PEAB3ATSF0150 A.20 PEAC2ATAM0025 A.12 PEAC3ATSE0125 A.16 PEAE2ATAK0150 A.20
E FETCA630A
FETCA640A
C.9
C.9
PEAB2ATEJ0125
PEAB2ATEJ0150
A.16
A.20
PEAB3ATSH0025
PEAB3ATSH0060
A.12
A.14
PEAC2ATAM0060
PEAC2ATAM0125
A.14
A.16
PEAC3ATSE0150
PEAC3ATSF0025
A.20
A.12
PEAE2ATAL0025
PEAE2ATAL0060
A.12
A.14
FEWA2 C.8 PEAB2ATEK0025 A.12 PEAB3ATSH0125 A.16 PEAC2ATAM0150 A.20 PEAC3ATSF0060 A.14 PEAE2ATAL0125 A.16
FGBEA3 C.8 PEAB2ATEK0060 A.14 PEAB3ATSH0150 A.20 PEAC2ATEJ0025 A.12 PEAC3ATSF0125 A.16 PEAE2ATAL0150 A.20
FGBEA4 C.8 PEAB2ATEK0125 A.16 PEAB3ATTN0020 A.7 PEAC2ATEJ0060 A.14 PEAC3ATSF0150 A.20 PEAE2ATAM0025 A.12
F FGBEH3
FGBEH4
C.8
C.8
PEAB2ATEK0150
PEAB2ATEL0025
A.20
A.12
PEAB3ATTN0025
PEAB3ATTN0030
A.7
A.7
PEAC2ATEJ0125
PEAC2ATEJ0150
A.16
A.20
PEAC3ATSH0025
PEAC3ATSH0060
A.12
A.14
PEAE2ATAM0060
PEAE2ATAM0125
A.14
A.16
FGBRC3 C.9 PEAB2ATEL0060 A.14 PEAB3ATTN0040 A.7 PEAC2ATEK0025 A.12 PEAC3ATSH0125 A.16 PEAE2ATAM0150 A.20
FGBRC4 C.9 PEAB2ATEL0125 A.16 PEAB3ATTN0050 A.7 PEAC2ATEK0060 A.14 PEAC3ATSH0150 A.20 PEAE2ATEJ0025 A.12
FGBRCS3 C.9 PEAB2ATEL0150 A.20 PEAB3ATTN0060 A.7 PEAC2ATEK0125 A.16 PEAC3ATTN0020 A.7 PEAE2ATEJ0060 A.14
FGBRCS4 C.9 PEAB3ATTR0070 PEAC2ATEK0150 PEAC3ATTN0025 PEAE2ATEJ0125
G FGBSS3
FGBSS4
C.8
PEAB2ATEM0025
PEAB2ATEM0060
A.12
A.14 PEAB3ATTR0080
A.7
A.7 PEAC2ATEL0025
A.20
A.12 PEAC3ATTN0030
A.7
A.7 PEAE2ATEJ0150
A.16
A.20
C.8 PEAB2ATEM0125 A.16 PEAB3ATTR0090 A.7 PEAC2ATEL0060 A.14 PEAC3ATTN0040 A.7 PEAE2ATEK0025 A.12
FGDDF3 C.7 PEAB2ATEM0150 A.20 PEAB3ATTR0100 A.7 PEAC2ATEL0125 A.16 PEAC3ATTN0050 A.7 PEAE2ATEK0060 A.14
FGDDF4 C.7 PEAB2ATGS0100 A.6 PEAB3ATTR0110 A.7 PEAC2ATEL0150 A.20 PEAC3ATTN0060 A.7 PEAE2ATEK0125 A.16
FGDMP3 C.7 PEAB2ATGS0110 A.6 PEAB3ATTR0125 A.7 PEAC2ATEM0025 A.12 PEAC3ATTR0070 A.7 PEAE2ATEK0150 A.20
X FGDMP4
FGFF3
C.7
C.7
PEAB2ATGS0125
PEAB2ATGS0150
A.6
A.6
PEAB3ATTR0150
PEAB4ATAJ0025
A.7
A.13
PEAC2ATEM0060
PEAC2ATEM0125
A.14
A.16
PEAC3ATTR0080
PEAC3ATTR0090
A.7
A.7
PEAE2ATEL0025
PEAE2ATEL0060
A.12
A.14
FGFF4 C.7 PEAB2ATSB0025 A.12 PEAB4ATAJ0060 A.15 PEAC2ATEM0150 A.20 PEAC3ATTR0100 A.7 PEAE2ATEL0125 A.16
FGJP C.10 PEAB2ATSB0060 A.14 PEAB4ATAJ0125 A.17 PEAC2ATGS0100 A.6 PEAC3ATTR0110 A.7 PEAE2ATEL0150 A.20
FGWA2 C.8 PEAB2ATSB0125 A.16 PEAB4ATAJ0150 A.21 PEAC2ATGS0110 A.6 PEAC3ATTR0125 A.7 PEAE2ATEM0025 A.12
FGWA3 C.8 PEAB2ATSB0150 A.20 PEAB4ATAK0025 A.13 PEAC2ATGS0125 A.6 PEAC3ATTR0150 A.7 PEAE2ATEM0060 A.14
P… PEAB2ATSE0025 A.12 PEAB4ATAK0060 A.15 PEAC2ATGS0150 A.6 PEAC4ATAJ0025 A.13 PEAE2ATEM0125 A.16
P1EMF8 C.5 PEAB2ATSE0060 A.14 PEAB4ATAK0125 A.17 PEAC2ATSB0025 A.12 PEAC4ATAJ0060 A.15 PEAE2ATEM0150 A.20
P1EMFD C.5 PEAB2ATSE0125 A.16 PEAB4ATAK0150 A.21 PEAC2ATSB0060 A.14 PEAC4ATAJ0125 A.17 PEAE2ATGS0100 A.6
P1EMFF C.5 PEAB2ATSE0150 A.20 PEAB4ATAL0025 A.13 PEAC2ATSB0125 A.16 PEAC4ATAJ0150 A.21 PEAE2ATGS0110 A.6
P1EMFN C.5 PEAB2ATSF0025 A.12 PEAB4ATAL0060 A.15 PEAC2ATSB0150 A.20 PEAC4ATAK0025 A.13 PEAE2ATGS0125 A.6
P1NFP C.5 PEAB2ATSF0060 A.14 PEAB4ATAL0125 A.17 PEAC2ATSE0025 A.12 PEAC4ATAK0060 A.15 PEAE2ATGS0150 A.6
P1NFT C.5 PEAB2ATSF0125 A.16 PEAB4ATAL0150 A.21 PEAC2ATSE0060 A.14 PEAC4ATAK0125 A.17 PEAE2ATSB0025 A.12
P1NRC C.4 PEAB2ATSF0150 A.20 PEAB4ATAM0025 A.13 PEAC2ATSE0125 A.16 PEAC4ATAK0150 A.21 PEAE2ATSB0060 A.14
P1NRCV C.4 PEAB2ATSH0025 A.12 PEAB4ATAM0060 A.15 PEAC2ATSE0150 A.20 PEAC4ATAL0025 A.13 PEAE2ATSB0125 A.16
P1NRD C.4 PEAB2ATSH0060 A.14 PEAB4ATAM0125 A.17 PEAC2ATSF0025 A.12 PEAC4ATAL0060 A.15 PEAE2ATSB0150 A.20

X.2
GuardEon
Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page
PEAE2ATSE0025 A.12 PEAE4ATAK0060 A.15 PEAH2ATGS0150 A.6 PEAH4ATAJ0025 A.13 PEAL2ATEM0125 A.16 PEAL3ATTR0090 A.7
PEAE2ATSE0060 A.14 PEAE4ATAK0125 A.17 PEAH2ATSB0025 A.12 PEAH4ATAJ0060 A.15 PEAL2ATEM0150 A.20 PEAL3ATTR0100 A.7
PEAE2ATSE0125 A.16 PEAE4ATAK0150 A.21 PEAH2ATSB0060 A.14 PEAH4ATAJ0125 A.17 PEAL2ATGS0100 A.6 PEAL3ATTR0110 A.7
PEAE2ATSE0150 A.20 PEAE4ATAL0025 A.13 PEAH2ATSB0125 A.16 PEAH4ATAJ0150 A.21 PEAL2ATGS0110 A.6 PEAL3ATTR0125 A.7
PEAE2ATSF0025 A.12 PEAE4ATAL0060 A.15 PEAH2ATSB0150 A.20 PEAH4ATAK0025 A.13 PEAL2ATGS0125 A.6 PEAL3ATTR0150 A.7
PEAE2ATSF0060 A.14 PEAE4ATAL0125 A.17 PEAH2ATSE0025 A.12 PEAH4ATAK0060 A.15 PEAL2ATGS0150 A.6 PEAL4ATAJ0025 A.13
PEAE2ATSF0125 A.16 PEAE4ATAL0150 A.21 PEAH2ATSE0060 A.14 PEAH4ATAK0125 A.17 PEAL2ATSB0025 A.12 PEAL4ATAJ0060 A.15
PEAE2ATSF0150 A.20 PEAE4ATAM0025 A.13 PEAH2ATSE0125 A.16 PEAH4ATAK0150 A.21 PEAL2ATSB0060 A.14 PEAL4ATAJ0125 A.17
PEAE2ATSH0025 A.12 PEAE4ATAM0060 A.15 PEAH2ATSE0150 A.20 PEAH4ATAL0025 A.13 PEAL2ATSB0125 A.16 PEAL4ATAJ0150 A.21
PEAE2ATSH0060 A.14 PEAE4ATAM0125 A.17 PEAH2ATSF0025 A.12 PEAH4ATAL0060 A.15 PEAL2ATSB0150 A.20 PEAL4ATAK0025 A.13
PEAE2ATSH0125 A.16 PEAE4ATAM0150 A.21 PEAH2ATSF0060 A.14 PEAH4ATAL0125 A.17 PEAL2ATSE0025 A.12 PEAL4ATAK0060 A.15
PEAE2ATSH0150 A.20 PEAE4ATEJ0025 A.13 PEAH2ATSF0125 A.16 PEAH4ATAL0150 A.21 PEAL2ATSE0060 A.14 PEAL4ATAK0125 A.17
PEAE2ATTN0020 A.6 PEAE4ATEJ0060 A.15 PEAH2ATSF0150 A.20 PEAH4ATAM0025 A.13 PEAL2ATSE0125 A.16 PEAL4ATAK0150 A.21
PEAE2ATTN0025 A.6 PEAE4ATEJ0125 A.17 PEAH2ATSH0025 A.12 PEAH4ATAM0060 A.15 PEAL2ATSE0150 A.20 PEAL4ATAL0025 A.13

By catalogue number
PEAE2ATTN0030 A.6 PEAE4ATEJ0150 A.21 PEAH2ATSH0060 A.14 PEAH4ATAM0125 A.17 PEAL2ATSF0025 A.12 PEAL4ATAL0060 A.15
PEAE2ATTN0040 A.6 PEAE4ATEK0025 A.13 PEAH2ATSH0125 A.16 PEAH4ATAM0150 A.21 PEAL2ATSF0060 A.14 PEAL4ATAL0125 A.17
PEAE2ATTN0050 A.6 PEAE4ATEK0060 A.15 PEAH2ATSH0150 A.20 PEAH4ATEJ0025 A.13 PEAL2ATSF0125 A.16 PEAL4ATAL0150 A.21
PEAE2ATTN0060 A.6 PEAE4ATEK0125 A.17 PEAH2ATTN0020 A.6 PEAH4ATEJ0060 A.15 PEAL2ATSF0150 A.20 PEAL4ATAM0025 A.13
PEAE2ATTR0070 A.6 PEAE4ATEK0150 A.21 PEAH2ATTN0025 A.6 PEAH4ATEJ0125 A.17 PEAL2ATSH0025 A.12 PEAL4ATAM0060 A.15
PEAE2ATTR0080 A.6 PEAE4ATEL0025 A.13 PEAH2ATTN0030 A.6 PEAH4ATEJ0150 A.21 PEAL2ATSH0060 A.14 PEAL4ATAM0125 A.17
PEAE2ATTR0090 A.6 PEAE4ATEL0060 A.15 PEAH2ATTN0040 A.6 PEAH4ATEK0025 A.13 PEAL2ATSH0125 A.16 PEAL4ATAM0150 A.21
PEAE2ATTR0100 A.6 PEAE4ATEL0125 A.17 PEAH2ATTN0050 A.6 PEAH4ATEK0060 A.15 PEAL2ATSH0150 A.20 PEAL4ATEJ0025 A.13
PEAE2ATTR0110 A.6 PEAE4ATEL0150 A.21 PEAH2ATTN0060 A.6 PEAH4ATEK0125 A.17 PEAL2ATTN0020 A.6 PEAL4ATEJ0060 A.15
PEAE2ATTR0125 A.6 PEAE4ATEM0025 A.13 PEAH2ATTR0070 A.6 PEAH4ATEK0150 A.21 PEAL2ATTN0025 A.6 PEAL4ATEJ0125 A.17
PEAE2ATTR0150 A.6 PEAE4ATEM0060 A.15 PEAH2ATTR0080 A.6 PEAH4ATEL0025 A.13 PEAL2ATTN0030 A.6 PEAL4ATEJ0150 A.21
PEAE3ATAJ0025 A.12 PEAE4ATEM0125 A.17 PEAH2ATTR0090 A.6 PEAH4ATEL0060 A.15 PEAL2ATTN0040 A.6 PEAL4ATEK0025 A.13
PEAE3ATAJ0060 A.14 PEAE4ATEM0150 A.21 PEAH2ATTR0100 A.6 PEAH4ATEL0125 A.17 PEAL2ATTN0050 A.6 PEAL4ATEK0060 A.15
PEAE3ATAJ0125 A.16 PEAE4ATGR0100 A.8 PEAH2ATTR0110 A.6 PEAH4ATEL0150 A.21 PEAL2ATTN0060 A.6 PEAL4ATEK0125 A.17
PEAE3ATAJ0150 A.20 PEAE4ATGR0110 A.8 PEAH2ATTR0125 A.6 PEAH4ATEM0025 A.13 PEAL2ATTR0070 A.6 PEAL4ATEK0150 A.21
PEAE3ATAK0025 A.12 PEAE4ATGR0125 A.8 PEAH2ATTR0150 A.6 PEAH4ATEM0060 A.15 PEAL2ATTR0080 A.6 PEAL4ATEL0025 A.13
PEAE3ATAK0060 A.14 PEAE4ATGR0150 A.8 PEAH3ATAJ0025 A.12 PEAH4ATEM0125 A.17 PEAL2ATTR0090 A.6 PEAL4ATEL0060 A.15
PEAE3ATAK0125 A.16 PEAE4ATSB0025 A.13 PEAH3ATAJ0060 A.14 PEAH4ATEM0150 A.21 PEAL2ATTR0100 A.6 PEAL4ATEL0125 A.17
PEAE3ATAK0150 A.20 PEAE4ATSB0060 A.15 PEAH3ATAJ0125 A.16 PEAH4ATGR0100 A.8 PEAL2ATTR0110 A.6 PEAL4ATEL0150 A.21
PEAE3ATAL0025 A.12 PEAE4ATSB0125 A.17 PEAH3ATAJ0150 A.20 PEAH4ATGR0110 A.8 PEAL2ATTR0125 A.6 PEAL4ATEM0025 A.13
PEAE3ATAL0060 A.14 PEAE4ATSB0150 A.21 PEAH3ATAK0025 A.12 PEAH4ATGR0125 A.8 PEAL2ATTR0150 A.6 PEAL4ATEM0060 A.15
PEAE3ATAL0125 A.16 PEAE4ATSE0025 A.13 PEAH3ATAK0060 A.14 PEAH4ATGR0150 A.8 PEAL3ATAJ0025 A.12 PEAL4ATEM0125 A.17
PEAE3ATAL0150
PEAE3ATAM0025
A.20
A.12
PEAE4ATSE0060
PEAE4ATSE0125
A.15
A.17
PEAH3ATAK0125
PEAH3ATAK0150
A.16
A.20
PEAH4ATSB0025
PEAH4ATSB0060
A.13
A.15
PEAL3ATAJ0060
PEAL3ATAJ0125
A.14
A.16
PEAL4ATEM0150
PEAL4ATGR0100
A.21
A.8
Intro
PEAE3ATAM0060 A.14 PEAE4ATSE0150 A.21 PEAH3ATAL0025 A.12 PEAH4ATSB0125 A.17 PEAL3ATAJ0150 A.20 PEAL4ATGR0110 A.8
PEAE3ATAM0125 A.16 PEAE4ATSF0025 A.13 PEAH3ATAL0060 A.14 PEAH4ATSB0150 A.21 PEAL3ATAK0025 A.12 PEAL4ATGR0125 A.8
PEAE3ATAM0150 A.20 PEAE4ATSF0060 A.15 PEAH3ATAL0125 A.16 PEAH4ATSE0025 A.13 PEAL3ATAK0060 A.14 PEAL4ATGR0150 A.8
PEAE3ATEJ0025
PEAE3ATEJ0060
A.12
A.14
PEAE4ATSF0125
PEAE4ATSF0150
A.17
A.21
PEAH3ATAL0150
PEAH3ATAM0025
A.20
A.12
PEAH4ATSE0060
PEAH4ATSE0125
A.15
A.17
PEAL3ATAK0125
PEAL3ATAK0150
A.16
A.20
PEAL4ATSB0025
PEAL4ATSB0060
A.13
A.15 A
PEAE3ATEJ0125 A.16 PEAE4ATSH0025 A.13 PEAH3ATAM0060 A.14 PEAH4ATSE0150 A.21 PEAL3ATAL0025 A.12 PEAL4ATSB0125 A.17
PEAE3ATEJ0150 A.20 PEAE4ATSH0060 A.15 PEAH3ATAM0125 A.16 PEAH4ATSF0025 A.13 PEAL3ATAL0060 A.14 PEAL4ATSB0150 A.21
PEAE3ATEK0025 A.12 PEAE4ATSH0125 A.17 PEAH3ATAM0150 A.20 PEAH4ATSF0060 A.15 PEAL3ATAL0125 A.16 PEAL4ATSE0025 A.13
PEAE3ATEK0060 A.14 PEAE4ATSH0150 A.21 PEAH3ATEJ0025 A.12 PEAH4ATSF0125 A.17 PEAL3ATAL0150 A.20 PEAL4ATSE0060 A.15
PEAE3ATEK0125
PEAE3ATEK0150
A.16
A.20
PEAE4ATTN0020
PEAE4ATTN0025
A.8
A.8
PEAH3ATEJ0060
PEAH3ATEJ0125
A.14
A.16
PEAH4ATSF0150
PEAH4ATSH0025
A.21
A.13
PEAL3ATAM0025
PEAL3ATAM0060
A.12
A.14
PEAL4ATSE0125
PEAL4ATSE0150
A.17
A.21
B
PEAE3ATEL0025 A.12 PEAE4ATTN0030 A.8 PEAH3ATEJ0150 A.20 PEAH4ATSH0060 A.15 PEAL3ATAM0125 A.16 PEAL4ATSF0025 A.13
PEAE3ATEL0060 A.14 PEAE4ATTN0040 A.8 PEAH3ATEK0025 A.12 PEAH4ATSH0125 A.17 PEAL3ATAM0150 A.20 PEAL4ATSF0060 A.15
PEAE3ATEL0125 A.16 PEAE4ATTN0050 A.8 PEAH3ATEK0060 A.14 PEAH4ATSH0150 A.21 PEAL3ATEJ0025 A.12 PEAL4ATSF0125 A.17
PEAE3ATEL0150
PEAE3ATEM0025
A.20
A.12
PEAE4ATTN0060
PEAE4ATTR0070
A.8
A.8
PEAH3ATEK0125
PEAH3ATEK0150
A.16
A.20
PEAH4ATTN0020
PEAH4ATTN0025
A.8
A.8
PEAL3ATEJ0060
PEAL3ATEJ0125
A.14
A.16
PEAL4ATSF0150
PEAL4ATSH0025
A.21
A.13
C
PEAE3ATEM0060 A.14 PEAE4ATTR0080 A.8 PEAH3ATEL0025 A.12 PEAH4ATTN0030 A.8 PEAL3ATEJ0150 A.20 PEAL4ATSH0060 A.15
PEAE3ATEM0125 A.16 PEAE4ATTR0090 A.8 PEAH3ATEL0060 A.14 PEAH4ATTN0040 A.8 PEAL3ATEK0025 A.12 PEAL4ATSH0125 A.17
PEAE3ATEM0150 A.20 PEAE4ATTR0100 A.8 PEAH3ATEL0125 A.16 PEAH4ATTN0050 A.8 PEAL3ATEK0060 A.14 PEAL4ATSH0150 A.21
PEAE3ATGR0100
PEAE3ATGR0110
A.7
A.7
PEAE4ATTR0110
PEAE4ATTR0125
A.8
A.8
PEAH3ATEL0150
PEAH3ATEM0025
A.20
A.12
PEAH4ATTN0060
PEAH4ATTR0070
A.8
A.8
PEAL3ATEK0125
PEAL3ATEK0150
A.16
A.20
PEAL4ATTN0020
PEAL4ATTN0025
A.8
A.8 D
PEAE3ATGR0125 A.7 PEAE4ATTR0150 A.8 PEAH3ATEM0060 A.14 PEAH4ATTR0080 A.8 PEAL3ATEL0025 A.12 PEAL4ATTN0030 A.8
PEAE3ATGR0150 A.7 PEAH2ATAJ0025 A.12 PEAH3ATEM0125 A.16 PEAH4ATTR0090 A.8 PEAL3ATEL0060 A.14 PEAL4ATTN0040 A.8
PEAE3ATSB0025 A.12 PEAH2ATAJ0060 A.14 PEAH3ATEM0150 A.20 PEAH4ATTR0100 A.8 PEAL3ATEL0125 A.16 PEAL4ATTN0050 A.8
PEAE3ATSB0060 A.14 PEAH2ATAJ0125 A.16 PEAH3ATGR0100 A.7 PEAH4ATTR0110 A.8 PEAL3ATEL0150 A.20 PEAL4ATTN0060 A.8
PEAE3ATSB0125
PEAE3ATSB0150
A.16
A.20
PEAH2ATAJ0150
PEAH2ATAK0025
A.20
A.12
PEAH3ATGR0110
PEAH3ATGR0125
A.7
A.7
PEAH4ATTR0125
PEAH4ATTR0150
A.8
A.8
PEAL3ATEM0025
PEAL3ATEM0060
A.12
A.14
PEAL4ATTR0070
PEAL4ATTR0080
A.8
A.8
E
PEAE3ATSE0025 A.12 PEAH2ATAK0060 A.14 PEAH3ATGR0150 A.7 PEAL2ATAJ0025 A.12 PEAL3ATEM0125 A.16 PEAL4ATTR0090 A.8
PEAE3ATSE0060 A.14 PEAH2ATAK0125 A.16 PEAH3ATSB0025 A.12 PEAL2ATAJ0060 A.14 PEAL3ATEM0150 A.20 PEAL4ATTR0100 A.8
PEAE3ATSE0125 A.16 PEAH2ATAK0150 A.20 PEAH3ATSB0060 A.14 PEAL2ATAJ0125 A.16 PEAL3ATGR0100 A.7 PEAL4ATTR0110 A.8
PEAE3ATSE0150
PEAE3ATSF0025
A.20
A.12
PEAH2ATAL0025
PEAH2ATAL0060
A.12
A.14
PEAH3ATSB0125
PEAH3ATSB0150
A.16
A.20
PEAL2ATAJ0150
PEAL2ATAK0025
A.20
A.12
PEAL3ATGR0110
PEAL3ATGR0125
A.7
A.7
PEAL4ATTR0125
PEAL4ATTR0150
A.8
A.8 F
PEAE3ATSF0060 A.14 PEAH2ATAL0125 A.16 PEAH3ATSE0025 A.12 PEAL2ATAK0060 A.14 PEAL3ATGR0150 A.7 PEAN2ATAJ0025 A.12
PEAE3ATSF0125 A.16 PEAH2ATAL0150 A.20 PEAH3ATSE0060 A.14 PEAL2ATAK0125 A.16 PEAL3ATSB0025 A.12 PEAN2ATAJ0060 A.14
PEAE3ATSF0150 A.20 PEAH2ATAM0025 A.12 PEAH3ATSE0125 A.16 PEAL2ATAK0150 A.20 PEAL3ATSB0060 A.14 PEAN2ATAJ0125 A.16
PEAE3ATSH0025 PEAH2ATAM0060 PEAH3ATSE0150 PEAL2ATAL0025 PEAL3ATSB0125 PEAN2ATAJ0150
PEAE3ATSH0060
A.12
A.14 PEAH2ATAM0125
A.14
A.16 PEAH3ATSF0025
A.20
A.12 PEAL2ATAL0060
A.12
A.14 PEAL3ATSB0150
A.16
A.20 PEAN2ATAK0025
A.20
A.12 G
PEAE3ATSH0125 A.16 PEAH2ATAM0150 A.20 PEAH3ATSF0060 A.14 PEAL2ATAL0125 A.16 PEAL3ATSE0025 A.12 PEAN2ATAK0060 A.14
PEAE3ATSH0150 A.20 PEAH2ATEJ0025 A.12 PEAH3ATSF0125 A.16 PEAL2ATAL0150 A.20 PEAL3ATSE0060 A.14 PEAN2ATAK0125 A.16
PEAE3ATTN0020 A.7 PEAH2ATEJ0060 A.14 PEAH3ATSF0150 A.20 PEAL2ATAM0025 A.12 PEAL3ATSE0125 A.16 PEAN2ATAK0150 A.20
PEAE3ATTN0025 A.7 PEAH2ATEJ0125 A.16 PEAH3ATSH0025 A.12 PEAL2ATAM0060 A.14 PEAL3ATSE0150 A.20 PEAN2ATAL0025 A.12
PEAE3ATTN0030
PEAE3ATTN0040
A.7
A.7
PEAH2ATEJ0150
PEAH2ATEK0025
A.20
A.12
PEAH3ATSH0060
PEAH3ATSH0125
A.14
A.16
PEAL2ATAM0125
PEAL2ATAM0150
A.16
A.20
PEAL3ATSF0025
PEAL3ATSF0060
A.12
A.14
PEAN2ATAL0060
PEAN2ATAL0125
A.14
A.16
X
PEAE3ATTN0050 A.7 PEAH2ATEK0060 A.14 PEAH3ATSH0150 A.20 PEAL2ATEJ0025 A.12 PEAL3ATSF0125 A.16 PEAN2ATAL0150 A.20
PEAE3ATTN0060 A.7 PEAH2ATEK0125 A.16 PEAH3ATTN0020 A.7 PEAL2ATEJ0060 A.14 PEAL3ATSF0150 A.20 PEAN2ATAM0025 A.12
PEAE3ATTR0070 A.7 PEAH2ATEK0150 A.20 PEAH3ATTN0025 A.7 PEAL2ATEJ0125 A.16 PEAL3ATSH0025 A.12 PEAN2ATAM0060 A.14
PEAE3ATTR0080 A.7 PEAH2ATEL0025 A.12 PEAH3ATTN0030 A.7 PEAL2ATEJ0150 A.20 PEAL3ATSH0060 A.14 PEAN2ATAM0125 A.16
PEAE3ATTR0090 A.7 PEAH2ATEL0060 A.14 PEAH3ATTN0040 A.7 PEAL2ATEK0025 A.12 PEAL3ATSH0125 A.16 PEAN2ATAM0150 A.20
PEAE3ATTR0100 A.7 PEAH2ATEL0125 A.16 PEAH3ATTN0050 A.7 PEAL2ATEK0060 A.14 PEAL3ATSH0150 A.20 PEAN2ATEJ0025 A.12
PEAE3ATTR0110 A.7 PEAH2ATEL0150 A.20 PEAH3ATTN0060 A.7 PEAL2ATEK0125 A.16 PEAL3ATTN0020 A.7 PEAN2ATEJ0060 A.14
PEAE3ATTR0125 A.7 PEAH2ATEM0025 A.12 PEAH3ATTR0070 A.7 PEAL2ATEK0150 A.20 PEAL3ATTN0025 A.7 PEAN2ATEJ0125 A.16
PEAE3ATTR0150 A.7 PEAH2ATEM0060 A.14 PEAH3ATTR0080 A.7 PEAL2ATEL0025 A.12 PEAL3ATTN0030 A.7 PEAN2ATEJ0150 A.20
PEAE4ATAJ0025 A.13 PEAH2ATEM0125 A.16 PEAH3ATTR0090 A.7 PEAL2ATEL0060 A.14 PEAL3ATTN0040 A.7 PEAN2ATEK0025 A.12
PEAE4ATAJ0060 A.15 PEAH2ATEM0150 A.20 PEAH3ATTR0100 A.7 PEAL2ATEL0125 A.16 PEAL3ATTN0050 A.7 PEAN2ATEK0060 A.14
PEAE4ATAJ0125 A.17 PEAH2ATGS0100 A.6 PEAH3ATTR0110 A.7 PEAL2ATEL0150 A.20 PEAL3ATTN0060 A.7 PEAN2ATEK0125 A.16
PEAE4ATAJ0150 A.21 PEAH2ATGS0110 A.6 PEAH3ATTR0125 A.7 PEAL2ATEM0025 A.12 PEAL3ATTR0070 A.7 PEAN2ATEK0150 A.20
PEAE4ATAK0025 A.13 PEAH2ATGS0125 A.6 PEAH3ATTR0150 A.7 PEAL2ATEM0060 A.14 PEAL3ATTR0080 A.7 PEAN2ATEL0025 A.12

X.3
GuardEon
Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page
PEAN2ATEL0060 A.14 PEAN3ATTN0040 A.7 PEBB2ATEJ0125 A.16 PEBB3ATSF0025 A.13 PEBC2ATAL0060 A.14 PEBC3ATGR0150 A.7
PEAN2ATEL0125 A.16 PEAN3ATTN0050 A.7 PEBB2ATEJ0150 A.20 PEBB3ATSF0060 A.15 PEBC2ATAL0125 A.16 PEBC3ATSB0025 A.13
PEAN2ATEL0150 A.20 PEAN3ATTN0060 A.7 PEBB2ATEJ0250 A.24 PEBB3ATSF0125 A.17 PEBC2ATAL0150 A.20 PEBC3ATSB0060 A.15
PEAN2ATEM0025 A.12 PEAN3ATTR0070 A.7 PEBB2ATEK0025 A.12 PEBB3ATSF0150 A.21 PEBC2ATAM0025 A.12 PEBC3ATSB0125 A.17
PEAN2ATEM0060 A.14 PEAN3ATTR0080 A.7 PEBB2ATEK0060 A.14 PEBB3ATSH0025 A.13 PEBC2ATAM0060 A.14 PEBC3ATSB0150 A.21
PEAN2ATEM0125 A.16 PEAN3ATTR0090 A.7 PEBB2ATEK0125 A.16 PEBB3ATSH0060 A.15 PEBC2ATAM0125 A.16 PEBC3ATSE0025 A.13
PEAN2ATEM0150 A.20 PEAN3ATTR0100 A.7 PEBB2ATEK0150 A.20 PEBB3ATSH0125 A.17 PEBC2ATAM0150 A.20 PEBC3ATSE0060 A.15
PEAN2ATGS0100 A.6 PEAN3ATTR0110 A.7 PEBB2ATEK0250 A.24 PEBB3ATSH0150 A.21 PEBC2ATEJ0025 A.12 PEBC3ATSE0125 A.17
PEAN2ATGS0110 A.6 PEAN3ATTR0125 A.7 PEBB2ATEL0025 A.12 PEBB3ATTN0020 A.7 PEBC2ATEJ0060 A.14 PEBC3ATSE0150 A.21
PEAN2ATGS0125 A.6 PEAN3ATTR0150 A.7 PEBB2ATEL0060 A.14 PEBB3ATTN0025 A.7 PEBC2ATEJ0125 A.16 PEBC3ATSF0025 A.13
PEAN2ATGS0150 A.6 PEAN4ATAJ0025 A.13 PEBB2ATEL0125 A.16 PEBB3ATTN0030 A.7 PEBC2ATEJ0150 A.20 PEBC3ATSF0060 A.15
PEAN2ATSB0025 A.12 PEAN4ATAJ0060 A.15 PEBB2ATEL0150 A.20 PEBB3ATTN0040 A.7 PEBC2ATEJ0250 A.24 PEBC3ATSF0125 A.17
PEAN2ATSB0060 A.14 PEAN4ATAJ0125 A.17 PEBB2ATEL0250 A.24 PEBB3ATTN0050 A.7 PEBC2ATEK0025 A.12 PEBC3ATSF0150 A.21
PEAN2ATSB0125 A.16 PEAN4ATAJ0150 A.21 PEBB2ATEM0025 A.12 PEBB3ATTN0060 A.7 PEBC2ATEK0060 A.14 PEBC3ATSH0025 A.13
PEAN2ATSB0150 A.20 PEAN4ATAK0025 A.13 PEBB2ATEM0060 A.14 PEBB3ATTR0070 A.7 PEBC2ATEK0125 A.16 PEBC3ATSH0060 A.15
PEAN2ATSE0025 A.12 PEAN4ATAK0060 A.15 PEBB2ATEM0125 A.16 PEBB3ATTR0080 A.7 PEBC2ATEK0150 A.20 PEBC3ATSH0125 A.17
PEAN2ATSE0060 A.14 PEAN4ATAK0125 A.17 PEBB2ATEM0150 A.20 PEBB3ATTR0090 A.7 PEBC2ATEK0250 A.24 PEBC3ATSH0150 A.21
PEAN2ATSE0125 A.16 PEAN4ATAK0150 A.21 PEBB2ATEM0250 A.24 PEBB3ATTR0100 A.7 PEBC2ATEL0025 A.12 PEBC3ATTN0020 A.7
Numerical index

PEAN2ATSE0150 A.20 PEAN4ATAL0025 A.13 PEBB2ATGR0100 A.6 PEBB3ATTR0110 A.7 PEBC2ATEL0060 A.14 PEBC3ATTN0025 A.7
PEAN2ATSF0025 A.12 PEAN4ATAL0060 A.15 PEBB2ATGR0110 A.6 PEBB3ATTR0125 A.7 PEBC2ATEL0125 A.16 PEBC3ATTN0030 A.7
PEAN2ATSF0060 A.14 PEAN4ATAL0125 A.17 PEBB2ATGR0125 A.6 PEBB3ATTR0150 A.7 PEBC2ATEL0150 A.20 PEBC3ATTN0040 A.7
PEAN2ATSF0125 A.16 PEAN4ATAL0150 A.21 PEBB2ATGR0150 A.6 PEBB4ATAJ0025 A.13 PEBC2ATEL0250 A.24 PEBC3ATTN0050 A.7
PEAN2ATSF0150 A.20 PEAN4ATAM0025 A.13 PEBB2ATSB0025 A.12 PEBB4ATAJ0060 A.15 PEBC2ATEM0025 A.12 PEBC3ATTN0060 A.7
PEAN2ATSH0025 A.12 PEAN4ATAM0060 A.15 PEBB2ATSB0060 A.14 PEBB4ATAJ0125 A.17 PEBC2ATEM0060 A.14 PEBC3ATTR0070 A.7
PEAN2ATSH0060 A.14 PEAN4ATAM0125 A.17 PEBB2ATSB0125 A.16 PEBB4ATAJ0150 A.21 PEBC2ATEM0125 A.16 PEBC3ATTR0080 A.7
PEAN2ATSH0125 A.16 PEAN4ATAM0150 A.21 PEBB2ATSB0150 A.20 PEBB4ATAK0025 A.13 PEBC2ATEM0150 A.20 PEBC3ATTR0090 A.7
PEAN2ATSH0150 A.20 PEAN4ATEJ0025 A.13 PEBB2ATSE0025 A.12 PEBB4ATAK0060 A.15 PEBC2ATEM0250 A.24 PEBC3ATTR0100 A.7
PEAN2ATTN0020 A.6 PEAN4ATEJ0060 A.15 PEBB2ATSE0060 A.14 PEBB4ATAK0125 A.17 PEBC2ATGR0100 A.6 PEBC3ATTR0110 A.7
PEAN2ATTN0025 A.6 PEAN4ATEJ0125 A.17 PEBB2ATSE0125 A.16 PEBB4ATAK0150 A.21 PEBC2ATGR0110 A.6 PEBC3ATTR0125 A.7
PEAN2ATTN0030 A.6 PEAN4ATEJ0150 A.21 PEBB2ATSE0150 A.20 PEBB4ATAL0025 A.13 PEBC2ATGR0125 A.6 PEBC3ATTR0150 A.7
PEAN2ATTN0040 A.6 PEAN4ATEK0025 A.13 PEBB2ATSF0025 A.12 PEBB4ATAL0060 A.15 PEBC2ATGR0150 A.6 PEBC4ATAJ0025 A.13
PEAN2ATTN0050 A.6 PEAN4ATEK0060 A.15 PEBB2ATSF0060 A.14 PEBB4ATAL0125 A.17 PEBC2ATSB0025 A.12 PEBC4ATAJ0060 A.15
PEAN2ATTN0060 A.6 PEAN4ATEK0125 A.17 PEBB2ATSF0125 A.16 PEBB4ATAL0150 A.21 PEBC2ATSB0060 A.14 PEBC4ATAJ0125 A.17
PEAN2ATTR0070 A.6 PEAN4ATEK0150 A.21 PEBB2ATSF0150 A.20 PEBB4ATAM0025 A.13 PEBC2ATSB0125 A.16 PEBC4ATAJ0150 A.21
PEAN2ATTR0080 A.6 PEAN4ATEL0025 A.13 PEBB2ATSH0025 A.12 PEBB4ATAM0060 A.15 PEBC2ATSB0150 A.20 PEBC4ATAK0025 A.13
PEAN2ATTR0090 A.6 PEAN4ATEL0060 A.15 PEBB2ATSH0060 A.14 PEBB4ATAM0125 A.17 PEBC2ATSE0025 A.12 PEBC4ATAK0060 A.15
Intro PEAN2ATTR0100
PEAN2ATTR0110
A.6
A.6
PEAN4ATEL0125
PEAN4ATEL0150
A.17
A.21
PEBB2ATSH0125
PEBB2ATSH0150
A.16
A.20
PEBB4ATAM0150
PEBB4ATEJ0025
A.21
A.13
PEBC2ATSE0060
PEBC2ATSE0125
A.14
A.16
PEBC4ATAK0125
PEBC4ATAK0150
A.17
A.21
PEAN2ATTR0125 A.6 PEAN4ATEM0025 A.13 PEBB2ATTN0020 A.6 PEBB4ATEJ0060 A.15 PEBC2ATSE0150 A.20 PEBC4ATAL0025 A.13
PEAN2ATTR0150 A.6 PEAN4ATEM0060 A.15 PEBB2ATTN0025 A.6 PEBB4ATEJ0125 A.17 PEBC2ATSF0025 A.12 PEBC4ATAL0060 A.15
PEAN3ATAJ0025 A.12 PEAN4ATEM0125 A.17 PEBB2ATTN0030 A.6 PEBB4ATEJ0150 A.21 PEBC2ATSF0060 A.14 PEBC4ATAL0125 A.17
A PEAN3ATAJ0060
PEAN3ATAJ0125
A.14
A.16
PEAN4ATEM0150
PEAN4ATGR0100
A.21
A.8
PEBB2ATTN0040
PEBB2ATTN0050
A.6
A.6
PEBB4ATEK0025
PEBB4ATEK0060
A.13
A.15
PEBC2ATSF0125
PEBC2ATSF0150
A.16
A.20
PEBC4ATAL0150
PEBC4ATAM0025
A.21
A.13
PEAN3ATAJ0150 A.20 PEAN4ATGR0110 A.8 PEBB2ATTN0060 A.6 PEBB4ATEK0125 A.17 PEBC2ATSH0025 A.12 PEBC4ATAM0060 A.15
PEAN3ATAK0025 A.12 PEAN4ATGR0125 A.8 PEBB2ATTR0070 A.6 PEBB4ATEK0150 A.21 PEBC2ATSH0060 A.14 PEBC4ATAM0125 A.17
PEAN3ATAK0060 A.14 PEAN4ATGR0150 A.8 PEBB2ATTR0080 A.6 PEBB4ATEL0025 A.13 PEBC2ATSH0125 A.16 PEBC4ATAM0150 A.21
PEAN3ATAK0125 A.16 PEAN4ATSB0025 A.13 PEBB2ATTR0090 A.6 PEBB4ATEL0060 A.15 PEBC2ATSH0150 A.20 PEBC4ATEJ0025 A.13
B PEAN3ATAK0150
PEAN3ATAL0025
A.20
A.12
PEAN4ATSB0060
PEAN4ATSB0125
A.15
A.17
PEBB2ATTR0100
PEBB2ATTR0110
A.6
A.6
PEBB4ATEL0125
PEBB4ATEL0150
A.17
A.21
PEBC2ATTN0020
PEBC2ATTN0025
A.6
A.6
PEBC4ATEJ0060
PEBC4ATEJ0125
A.15
A.17
PEAN3ATAL0060 A.14 PEAN4ATSB0150 A.21 PEBB2ATTR0125 A.6 PEBB4ATEM0025 A.13 PEBC2ATTN0030 A.6 PEBC4ATEJ0150 A.21
PEAN3ATAL0125 A.16 PEAN4ATSE0025 A.13 PEBB2ATTR0150 A.6 PEBB4ATEM0060 A.15 PEBC2ATTN0040 A.6 PEBC4ATEK0025 A.13
PEAN3ATAL0150 A.20 PEAN4ATSE0060 A.15 PEBB3ATAJ0025 A.13 PEBB4ATEM0125 A.17 PEBC2ATTN0050 A.6 PEBC4ATEK0060 A.15
C PEAN3ATAM0025
PEAN3ATAM0060
A.12
A.14
PEAN4ATSE0125
PEAN4ATSE0150
A.17
A.21
PEBB3ATAJ0060
PEBB3ATAJ0125
A.15
A.17
PEBB4ATEM0150
PEBB4ATGR0100
A.21
A.8
PEBC2ATTN0060
PEBC2ATTR0070
A.6
A.6
PEBC4ATEK0125
PEBC4ATEK0150
A.17
A.21
PEAN3ATAM0125 A.16 PEAN4ATSF0025 A.13 PEBB3ATAJ0150 A.21 PEBB4ATGR0110 A.8 PEBC2ATTR0080 A.6 PEBC4ATEL0025 A.13
PEAN3ATAM0150 A.20 PEAN4ATSF0060 A.15 PEBB3ATAK0025 A.13 PEBB4ATGR0125 A.8 PEBC2ATTR0090 A.6 PEBC4ATEL0060 A.15
PEAN3ATEJ0025 A.12 PEAN4ATSF0125 A.17 PEBB3ATAK0060 A.15 PEBB4ATGR0150 A.8 PEBC2ATTR0100 A.6 PEBC4ATEL0125 A.17
D PEAN3ATEJ0060
PEAN3ATEJ0125
A.14
A.16
PEAN4ATSF0150
PEAN4ATSH0025
A.21
A.13
PEBB3ATAK0125
PEBB3ATAK0150
A.17
A.21
PEBB4ATSB0025
PEBB4ATSB0060
A.13
A.15
PEBC2ATTR0110
PEBC2ATTR0125
A.6
A.6
PEBC4ATEL0150
PEBC4ATEM0025
A.21
A.13
PEAN3ATEJ0150 A.20 PEAN4ATSH0060 A.15 PEBB3ATAL0025 A.13 PEBB4ATSB0125 A.17 PEBC2ATTR0150 A.6 PEBC4ATEM0060 A.15
PEAN3ATEK0025 A.12 PEAN4ATSH0125 A.17 PEBB3ATAL0060 A.15 PEBB4ATSB0150 A.21 PEBC3ATAJ0025 A.13 PEBC4ATEM0125 A.17
PEAN3ATEK0060 A.14 PEAN4ATSH0150 A.21 PEBB3ATAL0125 A.17 PEBB4ATSE0025 A.13 PEBC3ATAJ0060 A.15 PEBC4ATEM0150 A.21
PEAN3ATEK0125 A.16 PEAN4ATTN0020 A.8 PEBB3ATAL0150 A.21 PEBB4ATSE0060 A.15 PEBC3ATAJ0125 A.17 PEBC4ATGR0100 A.8
E PEAN3ATEK0150
PEAN3ATEL0025
A.20
A.12
PEAN4ATTN0025
PEAN4ATTN0030
A.8
A.8
PEBB3ATAM0025
PEBB3ATAM0060
A.13
A.15
PEBB4ATSE0125
PEBB4ATSE0150
A.17
A.21
PEBC3ATAJ0150
PEBC3ATAK0025
A.21
A.13
PEBC4ATGR0110
PEBC4ATGR0125
A.8
A.8
PEAN3ATEL0060 A.14 PEAN4ATTN0040 A.8 PEBB3ATAM0125 A.17 PEBB4ATSF0025 A.13 PEBC3ATAK0060 A.15 PEBC4ATGR0150 A.8
PEAN3ATEL0125 A.16 PEAN4ATTN0050 A.8 PEBB3ATAM0150 A.21 PEBB4ATSF0060 A.15 PEBC3ATAK0125 A.17 PEBC4ATSB0025 A.13
PEAN3ATEL0150 A.20 PEAN4ATTN0060 A.8 PEBB3ATEJ0025 A.13 PEBB4ATSF0125 A.17 PEBC3ATAK0150 A.21 PEBC4ATSB0060 A.15
F PEAN3ATEM0025
PEAN3ATEM0060
A.12
A.14
PEAN4ATTR0070
PEAN4ATTR0080
A.8
A.8
PEBB3ATEJ0060
PEBB3ATEJ0125
A.15
A.17
PEBB4ATSF0150
PEBB4ATSH0025
A.21
A.13
PEBC3ATAL0025
PEBC3ATAL0060
A.13
A.15
PEBC4ATSB0125
PEBC4ATSB0150
A.17
A.21
PEAN3ATEM0125 A.16 PEAN4ATTR0090 A.8 PEBB3ATEJ0150 A.21 PEBB4ATSH0060 A.15 PEBC3ATAL0125 A.17 PEBC4ATSE0025 A.13
PEAN3ATEM0150 A.20 PEAN4ATTR0100 A.8 PEBB3ATEK0025 A.13 PEBB4ATSH0125 A.17 PEBC3ATAL0150 A.21 PEBC4ATSE0060 A.15
PEAN3ATGR0100 A.7 PEAN4ATTR0110 A.8 PEBB3ATEK0060 A.15 PEBB4ATSH0150 A.21 PEBC3ATAM0025 A.13 PEBC4ATSE0125 A.17
PEAN3ATGR0110 PEAN4ATTR0125 PEBB3ATEK0125 PEBB4ATTN0020 PEBC3ATAM0060 PEBC4ATSE0150
G PEAN3ATGR0125
A.7
A.7 PEAN4ATTR0150
A.8
A.8 PEBB3ATEK0150
A.17
A.21 PEBB4ATTN0025
A.8
A.8 PEBC3ATAM0125
A.15
A.17 PEBC4ATSF0025
A.21
A.13
PEAN3ATGR0150 A.7 PEAY3ATDU0150 A.7 PEBB3ATEL0025 A.13 PEBB4ATTN0030 A.8 PEBC3ATAM0150 A.21 PEBC4ATSF0060 A.15
PEAN3ATSB0025 A.12 PEAY3ATDU0250 A.10 PEBB3ATEL0060 A.15 PEBB4ATTN0040 A.8 PEBC3ATEJ0025 A.13 PEBC4ATSF0125 A.17
PEAN3ATSB0060 A.14 PEBB2ATAJ0025 A.12 PEBB3ATEL0125 A.17 PEBB4ATTN0050 A.8 PEBC3ATEJ0060 A.15 PEBC4ATSF0150 A.21
PEAN3ATSB0125 A.16 PEBB2ATAJ0060 A.14 PEBB3ATEL0150 A.21 PEBB4ATTN0060 A.8 PEBC3ATEJ0125 A.17 PEBC4ATSH0025 A.13
X PEAN3ATSB0150
PEAN3ATSE0025
A.20
A.12
PEBB2ATAJ0125
PEBB2ATAJ0150
A.16
A.20
PEBB3ATEM0025
PEBB3ATEM0060
A.13
A.15
PEBB4ATTR0070
PEBB4ATTR0080
A.8
A.8
PEBC3ATEJ0150
PEBC3ATEK0025
A.21
A.13
PEBC4ATSH0060
PEBC4ATSH0125
A.15
A.17
PEAN3ATSE0060 A.14 PEBB2ATAK0025 A.12 PEBB3ATEM0125 A.17 PEBB4ATTR0090 A.8 PEBC3ATEK0060 A.15 PEBC4ATSH0150 A.21
PEAN3ATSE0125 A.16 PEBB2ATAK0060 A.14 PEBB3ATEM0150 A.21 PEBB4ATTR0100 A.8 PEBC3ATEK0125 A.17 PEBC4ATTN0020 A.8
PEAN3ATSE0150 A.20 PEBB2ATAK0125 A.16 PEBB3ATGR0100 A.7 PEBB4ATTR0110 A.8 PEBC3ATEK0150 A.21 PEBC4ATTN0025 A.8
PEAN3ATSF0025 A.12 PEBB2ATAK0150 A.20 PEBB3ATGR0110 A.7 PEBB4ATTR0125 A.8 PEBC3ATEL0025 A.13 PEBC4ATTN0030 A.8
PEAN3ATSF0060 A.14 PEBB2ATAL0025 A.12 PEBB3ATGR0125 A.7 PEBB4ATTR0150 A.8 PEBC3ATEL0060 A.15 PEBC4ATTN0040 A.8
PEAN3ATSF0125 A.16 PEBB2ATAL0060 A.14 PEBB3ATGR0150 A.7 PEBC2ATAJ0025 A.12 PEBC3ATEL0125 A.17 PEBC4ATTN0050 A.8
PEAN3ATSF0150 A.20 PEBB2ATAL0125 A.16 PEBB3ATSB0025 A.13 PEBC2ATAJ0060 A.14 PEBC3ATEL0150 A.21 PEBC4ATTN0060 A.8
PEAN3ATSH0025 A.12 PEBB2ATAL0150 A.20 PEBB3ATSB0060 A.15 PEBC2ATAJ0125 A.16 PEBC3ATEM0025 A.13 PEBC4ATTR0070 A.8
PEAN3ATSH0060 A.14 PEBB2ATAM0025 A.12 PEBB3ATSB0125 A.17 PEBC2ATAJ0150 A.20 PEBC3ATEM0060 A.15 PEBC4ATTR0080 A.8
PEAN3ATSH0125 A.16 PEBB2ATAM0060 A.14 PEBB3ATSB0150 A.21 PEBC2ATAK0025 A.12 PEBC3ATEM0125 A.17 PEBC4ATTR0090 A.8
PEAN3ATSH0150 A.20 PEBB2ATAM0125 A.16 PEBB3ATSE0025 A.13 PEBC2ATAK0060 A.14 PEBC3ATEM0150 A.21 PEBC4ATTR0100 A.8
PEAN3ATTN0020 A.7 PEBB2ATAM0150 A.20 PEBB3ATSE0060 A.15 PEBC2ATAK0125 A.16 PEBC3ATGR0100 A.7 PEBC4ATTR0110 A.8
PEAN3ATTN0025 A.7 PEBB2ATEJ0025 A.12 PEBB3ATSE0125 A.17 PEBC2ATAK0150 A.20 PEBC3ATGR0110 A.7 PEBC4ATTR0125 A.8
PEAN3ATTN0030 A.7 PEBB2ATEJ0060 A.14 PEBB3ATSE0150 A.21 PEBC2ATAL0025 A.12 PEBC3ATGR0125 A.7 PEBC4ATTR0150 A.8

X.4
GuardEon
Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page
PEBE2ATAJ0025 A.12 PEBE3ATEL0125 A.17 PEBE4ATTN0050 A.8 PEBH3ATEJ0060 A.15 PEBH4ATSF0150 A.21 PEBL3ATAL0025 A.13
PEBE2ATAJ0060 A.14 PEBE3ATEL0150 A.21 PEBE4ATTN0060 A.8 PEBH3ATEJ0125 A.17 PEBH4ATSH0025 A.13 PEBL3ATAL0060 A.15
PEBE2ATAJ0125 A.16 PEBE3ATEM0025 A.13 PEBE4ATTR0070 A.8 PEBH3ATEJ0150 A.21 PEBH4ATSH0060 A.15 PEBL3ATAL0125 A.17
PEBE2ATAJ0150 A.20 PEBE3ATEM0060 A.15 PEBE4ATTR0080 A.8 PEBH3ATEK0025 A.13 PEBH4ATSH0125 A.17 PEBL3ATAL0150 A.21
PEBE2ATAK0025 A.12 PEBE3ATEM0125 A.17 PEBE4ATTR0090 A.8 PEBH3ATEK0060 A.15 PEBH4ATSH0150 A.21 PEBL3ATAM0025 A.13
PEBE2ATAK0060 A.14 PEBE3ATEM0150 A.21 PEBE4ATTR0100 A.8 PEBH3ATEK0125 A.17 PEBH4ATTN0020 A.8 PEBL3ATAM0060 A.15
PEBE2ATAK0125 A.16 PEBE3ATGR0100 A.7 PEBE4ATTR0110 A.8 PEBH3ATEK0150 A.21 PEBH4ATTN0025 A.8 PEBL3ATAM0125 A.17
PEBE2ATAK0150 A.20 PEBE3ATGR0110 A.7 PEBE4ATTR0125 A.8 PEBH3ATEL0025 A.13 PEBH4ATTN0030 A.8 PEBL3ATAM0150 A.21
PEBE2ATAL0025 A.12 PEBE3ATGR0125 A.7 PEBE4ATTR0150 A.8 PEBH3ATEL0060 A.15 PEBH4ATTN0040 A.8 PEBL3ATEJ0025 A.13
PEBE2ATAL0060 A.14 PEBE3ATGR0150 A.7 PEBH2ATAJ0025 A.12 PEBH3ATEL0125 A.17 PEBH4ATTN0050 A.8 PEBL3ATEJ0060 A.15
PEBE2ATAL0125 A.16 PEBE3ATSB0025 A.13 PEBH2ATAJ0060 A.14 PEBH3ATEL0150 A.21 PEBH4ATTN0060 A.8 PEBL3ATEJ0125 A.17
PEBE2ATAL0150 A.20 PEBE3ATSB0060 A.15 PEBH2ATAJ0125 A.16 PEBH3ATEM0025 A.13 PEBH4ATTR0070 A.8 PEBL3ATEJ0150 A.21
PEBE2ATAM0025 A.12 PEBE3ATSB0125 A.17 PEBH2ATAJ0150 A.20 PEBH3ATEM0060 A.15 PEBH4ATTR0080 A.8 PEBL3ATEK0025 A.13
PEBE2ATAM0060 A.14 PEBE3ATSB0150 A.21 PEBH2ATAK0025 A.12 PEBH3ATEM0125 A.17 PEBH4ATTR0090 A.8 PEBL3ATEK0060 A.15

By catalogue number
PEBE2ATAM0125 A.16 PEBE3ATSE0025 A.13 PEBH2ATAK0060 A.14 PEBH3ATEM0150 A.21 PEBH4ATTR0100 A.8 PEBL3ATEK0125 A.17
PEBE2ATAM0150 A.20 PEBE3ATSE0060 A.15 PEBH2ATAK0125 A.16 PEBH3ATGR0100 A.7 PEBH4ATTR0110 A.8 PEBL3ATEK0150 A.21
PEBE2ATEJ0025 A.12 PEBE3ATSE0125 A.17 PEBH2ATAK0150 A.20 PEBH3ATGR0110 A.7 PEBH4ATTR0125 A.8 PEBL3ATEL0025 A.13
PEBE2ATEJ0060 A.14 PEBE3ATSE0150 A.21 PEBH2ATAL0025 A.12 PEBH3ATGR0125 A.7 PEBH4ATTR0150 A.8 PEBL3ATEL0060 A.15
PEBE2ATEJ0125 A.16 PEBE3ATSF0025 A.13 PEBH2ATAL0060 A.14 PEBH3ATGR0150 A.7 PEBL2ATAJ0025 A.12 PEBL3ATEL0125 A.17
PEBE2ATEJ0150 A.20 PEBE3ATSF0060 A.15 PEBH2ATAL0125 A.16 PEBH3ATSB0025 A.13 PEBL2ATAJ0060 A.14 PEBL3ATEL0150 A.21
PEBE2ATEJ0250 A.24 PEBE3ATSF0125 A.17 PEBH2ATAL0150 A.20 PEBH3ATSB0060 A.15 PEBL2ATAJ0125 A.16 PEBL3ATEM0025 A.13
PEBE2ATEK0025 A.12 PEBE3ATSF0150 A.21 PEBH2ATAM0025 A.12 PEBH3ATSB0125 A.17 PEBL2ATAJ0150 A.20 PEBL3ATEM0060 A.15
PEBE2ATEK0060 A.14 PEBE3ATSH0025 A.13 PEBH2ATAM0060 A.14 PEBH3ATSB0150 A.21 PEBL2ATAK0025 A.12 PEBL3ATEM0125 A.17
PEBE2ATEK0125 A.16 PEBE3ATSH0060 A.15 PEBH2ATAM0125 A.16 PEBH3ATSE0025 A.13 PEBL2ATAK0060 A.14 PEBL3ATEM0150 A.21
PEBE2ATEK0150 A.20 PEBE3ATSH0125 A.17 PEBH2ATAM0150 A.20 PEBH3ATSE0060 A.15 PEBL2ATAK0125 A.16 PEBL3ATGR0100 A.7
PEBE2ATEK0250 A.24 PEBE3ATSH0150 A.21 PEBH2ATEJ0025 A.12 PEBH3ATSE0125 A.17 PEBL2ATAK0150 A.20 PEBL3ATGR0110 A.7
PEBE2ATEL0025 A.12 PEBE3ATTN0020 A.7 PEBH2ATEJ0060 A.14 PEBH3ATSE0150 A.21 PEBL2ATAL0025 A.12 PEBL3ATGR0125 A.7
PEBE2ATEL0060 A.14 PEBE3ATTN0025 A.7 PEBH2ATEJ0125 A.16 PEBH3ATSF0025 A.13 PEBL2ATAL0060 A.14 PEBL3ATGR0150 A.7
PEBE2ATEL0125 A.16 PEBE3ATTN0030 A.7 PEBH2ATEJ0150 A.20 PEBH3ATSF0060 A.15 PEBL2ATAL0125 A.16 PEBL3ATSB0025 A.13
PEBE2ATEL0150 A.20 PEBE3ATTN0040 A.7 PEBH2ATEJ0250 A.24 PEBH3ATSF0125 A.17 PEBL2ATAL0150 A.20 PEBL3ATSB0060 A.15
PEBE2ATEL0250 A.24 PEBE3ATTN0050 A.7 PEBH2ATEK0025 A.12 PEBH3ATSF0150 A.21 PEBL2ATAM0025 A.12 PEBL3ATSB0125 A.17
PEBE2ATEM0025 A.12 PEBE3ATTN0060 A.7 PEBH2ATEK0060 A.14 PEBH3ATSH0025 A.13 PEBL2ATAM0060 A.14 PEBL3ATSB0150 A.21
PEBE2ATEM0060 A.14 PEBE3ATTR0070 A.7 PEBH2ATEK0125 A.16 PEBH3ATSH0060 A.15 PEBL2ATAM0125 A.16 PEBL3ATSE0025 A.13
PEBE2ATEM0125 A.16 PEBE3ATTR0080 A.7 PEBH2ATEK0150 A.20 PEBH3ATSH0125 A.17 PEBL2ATAM0150 A.20 PEBL3ATSE0060 A.15
PEBE2ATEM0150 A.20 PEBE3ATTR0090 A.7 PEBH2ATEK0250 A.24 PEBH3ATSH0150 A.21 PEBL2ATEJ0025 A.12 PEBL3ATSE0125 A.17
PEBE2ATEM0250 A.24 PEBE3ATTR0100 A.7 PEBH2ATEL0025 A.12 PEBH3ATTN0020 A.7 PEBL2ATEJ0060 A.14 PEBL3ATSE0150 A.21
PEBE2ATGR0100
PEBE2ATGR0110
A.6
A.6
PEBE3ATTR0110
PEBE3ATTR0125
A.7
A.7
PEBH2ATEL0060
PEBH2ATEL0125
A.14
A.16
PEBH3ATTN0025
PEBH3ATTN0030
A.7
A.7
PEBL2ATEJ0125
PEBL2ATEJ0150
A.16
A.20
PEBL3ATSF0025
PEBL3ATSF0060
A.13
A.15
Intro
PEBE2ATGR0125 A.6 PEBE3ATTR0150 A.7 PEBH2ATEL0150 A.20 PEBH3ATTN0040 A.7 PEBL2ATEJ0250 A.24 PEBL3ATSF0125 A.17
PEBE2ATGR0150 A.6 PEBE4ATAJ0025 A.13 PEBH2ATEL0250 A.24 PEBH3ATTN0050 A.7 PEBL2ATEK0025 A.12 PEBL3ATSF0150 A.21
PEBE2ATSB0025 A.12 PEBE4ATAJ0060 A.15 PEBH2ATEM0025 A.12 PEBH3ATTN0060 A.7 PEBL2ATEK0060 A.14 PEBL3ATSH0025 A.13
PEBE2ATSB0060
PEBE2ATSB0125
A.14
A.16
PEBE4ATAJ0125
PEBE4ATAJ0150
A.17
A.21
PEBH2ATEM0060
PEBH2ATEM0125
A.14
A.16
PEBH3ATTR0070
PEBH3ATTR0080
A.7
A.7
PEBL2ATEK0125
PEBL2ATEK0150
A.16
A.20
PEBL3ATSH0060
PEBL3ATSH0125
A.15
A.17 A
PEBE2ATSB0150 A.20 PEBE4ATAK0025 A.13 PEBH2ATEM0150 A.20 PEBH3ATTR0090 A.7 PEBL2ATEK0250 A.24 PEBL3ATSH0150 A.21
PEBE2ATSE0025 A.12 PEBE4ATAK0060 A.15 PEBH2ATEM0250 A.24 PEBH3ATTR0100 A.7 PEBL2ATEL0025 A.12 PEBL3ATTN0020 A.7
PEBE2ATSE0060 A.14 PEBE4ATAK0125 A.17 PEBH2ATGR0100 A.6 PEBH3ATTR0110 A.7 PEBL2ATEL0060 A.14 PEBL3ATTN0025 A.7
PEBE2ATSE0125 A.16 PEBE4ATAK0150 A.21 PEBH2ATGR0110 A.6 PEBH3ATTR0125 A.7 PEBL2ATEL0125 A.16 PEBL3ATTN0030 A.7
PEBE2ATSE0150
PEBE2ATSF0025
A.20
A.12
PEBE4ATAL0025
PEBE4ATAL0060
A.13
A.15
PEBH2ATGR0125
PEBH2ATGR0150
A.6
A.6
PEBH3ATTR0150
PEBH4ATAJ0025
A.7
A.13
PEBL2ATEL0150
PEBL2ATEL0250
A.20
A.24
PEBL3ATTN0040
PEBL3ATTN0050
A.7
A.7
B
PEBE2ATSF0060 A.14 PEBE4ATAL0125 A.17 PEBH2ATSB0025 A.12 PEBH4ATAJ0060 A.15 PEBL2ATEM0025 A.12 PEBL3ATTN0060 A.7
PEBE2ATSF0125 A.16 PEBE4ATAL0150 A.21 PEBH2ATSB0060 A.14 PEBH4ATAJ0125 A.17 PEBL2ATEM0060 A.14 PEBL3ATTR0070 A.7
PEBE2ATSF0150 A.20 PEBE4ATAM0025 A.13 PEBH2ATSB0125 A.16 PEBH4ATAJ0150 A.21 PEBL2ATEM0125 A.16 PEBL3ATTR0080 A.7
PEBE2ATSH0025
PEBE2ATSH0060
A.12
A.14
PEBE4ATAM0060
PEBE4ATAM0125
A.15
A.17
PEBH2ATSB0150
PEBH2ATSE0025
A.20
A.12
PEBH4ATAK0025
PEBH4ATAK0060
A.13
A.15
PEBL2ATEM0150
PEBL2ATEM0250
A.20
A.24
PEBL3ATTR0090
PEBL3ATTR0100
A.7
A.7
C
PEBE2ATSH0125 A.16 PEBE4ATAM0150 A.21 PEBH2ATSE0060 A.14 PEBH4ATAK0125 A.17 PEBL2ATGR0100 A.6 PEBL3ATTR0110 A.7
PEBE2ATSH0150 A.20 PEBE4ATEJ0025 A.13 PEBH2ATSE0125 A.16 PEBH4ATAK0150 A.21 PEBL2ATGR0110 A.6 PEBL3ATTR0125 A.7
PEBE2ATTN0020 A.6 PEBE4ATEJ0060 A.15 PEBH2ATSE0150 A.20 PEBH4ATAL0025 A.13 PEBL2ATGR0125 A.6 PEBL3ATTR0150 A.7
PEBE2ATTN0025
PEBE2ATTN0030
A.6
A.6
PEBE4ATEJ0125
PEBE4ATEJ0150
A.17
A.21
PEBH2ATSF0025
PEBH2ATSF0060
A.12
A.14
PEBH4ATAL0060
PEBH4ATAL0125
A.15
A.17
PEBL2ATGR0150
PEBL2ATSB0025
A.6
A.12
PEBL4ATAJ0025
PEBL4ATAJ0060
A.13
A.15 D
PEBE2ATTN0040 A.6 PEBE4ATEK0025 A.13 PEBH2ATSF0125 A.16 PEBH4ATAL0150 A.21 PEBL2ATSB0060 A.14 PEBL4ATAJ0125 A.17
PEBE2ATTN0050 A.6 PEBE4ATEK0060 A.15 PEBH2ATSF0150 A.20 PEBH4ATAM0025 A.13 PEBL2ATSB0125 A.16 PEBL4ATAJ0150 A.21
PEBE2ATTN0060 A.6 PEBE4ATEK0125 A.17 PEBH2ATSH0025 A.12 PEBH4ATAM0060 A.15 PEBL2ATSB0150 A.20 PEBL4ATAK0025 A.13
PEBE2ATTR0070 A.6 PEBE4ATEK0150 A.21 PEBH2ATSH0060 A.14 PEBH4ATAM0125 A.17 PEBL2ATSE0025 A.12 PEBL4ATAK0060 A.15
PEBE2ATTR0080
PEBE2ATTR0090
A.6
A.6
PEBE4ATEL0025
PEBE4ATEL0060
A.13
A.15
PEBH2ATSH0125
PEBH2ATSH0150
A.16
A.20
PEBH4ATAM0150
PEBH4ATEJ0025
A.21
A.13
PEBL2ATSE0060
PEBL2ATSE0125
A.14
A.16
PEBL4ATAK0125
PEBL4ATAK0150
A.17
A.21
E
PEBE2ATTR0100 A.6 PEBE4ATEL0125 A.17 PEBH2ATTN0020 A.6 PEBH4ATEJ0060 A.15 PEBL2ATSE0150 A.20 PEBL4ATAL0025 A.13
PEBE2ATTR0110 A.6 PEBE4ATEL0150 A.21 PEBH2ATTN0025 A.6 PEBH4ATEJ0125 A.17 PEBL2ATSF0025 A.12 PEBL4ATAL0060 A.15
PEBE2ATTR0125 A.6 PEBE4ATEM0025 A.13 PEBH2ATTN0030 A.6 PEBH4ATEJ0150 A.21 PEBL2ATSF0060 A.14 PEBL4ATAL0125 A.17
PEBE2ATTR0150
PEBE3ATAJ0025
A.6
A.13
PEBE4ATEM0060
PEBE4ATEM0125
A.15
A.17
PEBH2ATTN0040
PEBH2ATTN0050
A.6
A.6
PEBH4ATEK0025
PEBH4ATEK0060
A.13
A.15
PEBL2ATSF0125
PEBL2ATSF0150
A.16
A.20
PEBL4ATAL0150
PEBL4ATAM0025
A.21
A.13 F
PEBE3ATAJ0060 A.15 PEBE4ATEM0150 A.21 PEBH2ATTN0060 A.6 PEBH4ATEK0125 A.17 PEBL2ATSH0025 A.12 PEBL4ATAM0060 A.15
PEBE3ATAJ0125 A.17 PEBE4ATGR0100 A.8 PEBH2ATTR0070 A.6 PEBH4ATEK0150 A.21 PEBL2ATSH0060 A.14 PEBL4ATAM0125 A.17
PEBE3ATAJ0150 A.21 PEBE4ATGR0110 A.8 PEBH2ATTR0080 A.6 PEBH4ATEL0025 A.13 PEBL2ATSH0125 A.16 PEBL4ATAM0150 A.21
PEBE3ATAK0025 PEBE4ATGR0125 PEBH2ATTR0090 PEBH4ATEL0060 PEBL2ATSH0150 PEBL4ATEJ0025
PEBE3ATAK0060
A.13
A.15 PEBE4ATGR0150
A.8
A.8 PEBH2ATTR0100
A.6
A.6 PEBH4ATEL0125
A.15
A.17 PEBL2ATTN0020
A.20
A.6 PEBL4ATEJ0060
A.13
A.15 G
PEBE3ATAK0125 A.17 PEBE4ATSB0025 A.13 PEBH2ATTR0110 A.6 PEBH4ATEL0150 A.21 PEBL2ATTN0025 A.6 PEBL4ATEJ0125 A.17
PEBE3ATAK0150 A.21 PEBE4ATSB0060 A.15 PEBH2ATTR0125 A.6 PEBH4ATEM0025 A.13 PEBL2ATTN0030 A.6 PEBL4ATEJ0150 A.21
PEBE3ATAL0025 A.13 PEBE4ATSB0125 A.17 PEBH2ATTR0150 A.6 PEBH4ATEM0060 A.15 PEBL2ATTN0040 A.6 PEBL4ATEK0025 A.13
PEBE3ATAL0060 A.15 PEBE4ATSB0150 A.21 PEBH3ATAJ0025 A.13 PEBH4ATEM0125 A.17 PEBL2ATTN0050 A.6 PEBL4ATEK0060 A.15
PEBE3ATAL0125
PEBE3ATAL0150
A.17
A.21
PEBE4ATSE0025
PEBE4ATSE0060
A.13
A.15
PEBH3ATAJ0060
PEBH3ATAJ0125
A.15
A.17
PEBH4ATEM0150
PEBH4ATGR0100
A.21
A.8
PEBL2ATTN0060
PEBL2ATTR0070
A.6
A.6
PEBL4ATEK0125
PEBL4ATEK0150
A.17
A.21
X
PEBE3ATAM0025 A.13 PEBE4ATSE0125 A.17 PEBH3ATAJ0150 A.21 PEBH4ATGR0110 A.8 PEBL2ATTR0080 A.6 PEBL4ATEL0025 A.13
PEBE3ATAM0060 A.15 PEBE4ATSE0150 A.21 PEBH3ATAK0025 A.13 PEBH4ATGR0125 A.8 PEBL2ATTR0090 A.6 PEBL4ATEL0060 A.15
PEBE3ATAM0125 A.17 PEBE4ATSF0025 A.13 PEBH3ATAK0060 A.15 PEBH4ATGR0150 A.8 PEBL2ATTR0100 A.6 PEBL4ATEL0125 A.17
PEBE3ATAM0150 A.21 PEBE4ATSF0060 A.15 PEBH3ATAK0125 A.17 PEBH4ATSB0025 A.13 PEBL2ATTR0110 A.6 PEBL4ATEL0150 A.21
PEBE3ATEJ0025 A.13 PEBE4ATSF0125 A.17 PEBH3ATAK0150 A.21 PEBH4ATSB0060 A.15 PEBL2ATTR0125 A.6 PEBL4ATEM0025 A.13
PEBE3ATEJ0060 A.15 PEBE4ATSF0150 A.21 PEBH3ATAL0025 A.13 PEBH4ATSB0125 A.17 PEBL2ATTR0150 A.6 PEBL4ATEM0060 A.15
PEBE3ATEJ0125 A.17 PEBE4ATSH0025 A.13 PEBH3ATAL0060 A.15 PEBH4ATSB0150 A.21 PEBL3ATAJ0025 A.13 PEBL4ATEM0125 A.17
PEBE3ATEJ0150 A.21 PEBE4ATSH0060 A.15 PEBH3ATAL0125 A.17 PEBH4ATSE0025 A.13 PEBL3ATAJ0060 A.15 PEBL4ATEM0150 A.21
PEBE3ATEK0025 A.13 PEBE4ATSH0125 A.17 PEBH3ATAL0150 A.21 PEBH4ATSE0060 A.15 PEBL3ATAJ0125 A.17 PEBL4ATGR0100 A.8
PEBE3ATEK0060 A.15 PEBE4ATSH0150 A.21 PEBH3ATAM0025 A.13 PEBH4ATSE0125 A.17 PEBL3ATAJ0150 A.21 PEBL4ATGR0110 A.8
PEBE3ATEK0125 A.17 PEBE4ATTN0020 A.8 PEBH3ATAM0060 A.15 PEBH4ATSE0150 A.21 PEBL3ATAK0025 A.13 PEBL4ATGR0125 A.8
PEBE3ATEK0150 A.21 PEBE4ATTN0025 A.8 PEBH3ATAM0125 A.17 PEBH4ATSF0025 A.13 PEBL3ATAK0060 A.15 PEBL4ATGR0150 A.8
PEBE3ATEL0025 A.13 PEBE4ATTN0030 A.8 PEBH3ATAM0150 A.21 PEBH4ATSF0060 A.15 PEBL3ATAK0125 A.17 PEBL4ATSB0025 A.13
PEBE3ATEL0060 A.15 PEBE4ATTN0040 A.8 PEBH3ATEJ0025 A.13 PEBH4ATSF0125 A.17 PEBL3ATAK0150 A.21 PEBL4ATSB0060 A.15

X.5
GuardEon
Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page
PEBL4ATSB0125 A.17 PEBN2ATTR0150 A.6 PEBN4ATEM0060 A.15 PEDB3ATEJ0150 A.22 PEDC2ATEK0150 A.22 PEDC4ATEL0150 A.23
PEBL4ATSB0150 A.21 PEBN3ATAJ0025 A.13 PEBN4ATEM0125 A.17 PEDB3ATEJ0250 A.24 PEDC2ATEK0250 A.24 PEDC4ATEL0250 A.25
PEBL4ATSE0025 A.13 PEBN3ATAJ0060 A.15 PEBN4ATEM0150 A.21 PEDB3ATEK0125 A.18 PEDC2ATEL0125 A.18 PEDC4ATEM0125 A.19
PEBL4ATSE0060 A.15 PEBN3ATAJ0125 A.17 PEBN4ATGR0100 A.8 PEDB3ATEK0150 A.22 PEDC2ATEL0150 A.22 PEDC4ATEM0150 A.23
PEBL4ATSE0125 A.17 PEBN3ATAJ0150 A.21 PEBN4ATGR0110 A.8 PEDB3ATEK0250 A.24 PEDC2ATEL0250 A.24 PEDC4ATEM0250 A.25
PEBL4ATSE0150 A.21 PEBN3ATAK0025 A.13 PEBN4ATGR0125 A.8 PEDB3ATEL0125 A.18 PEDC2ATEM0125 A.18 PEDC4ATGR0125 A.11
PEBL4ATSF0025 A.13 PEBN3ATAK0060 A.15 PEBN4ATGR0150 A.8 PEDB3ATEL0150 A.22 PEDC2ATEM0150 A.22 PEDC4ATGR0150 A.11
PEBL4ATSF0060 A.15 PEBN3ATAK0125 A.17 PEBN4ATSB0025 A.13 PEDB3ATEL0250 A.24 PEDC2ATEM0250 A.24 PEDC4ATGR0200 A.11
PEBL4ATSF0125 A.17 PEBN3ATAK0150 A.21 PEBN4ATSB0060 A.15 PEDB3ATEM0125 A.18 PEDC2ATGR0125 A.9 PEDC4ATGR0225 A.11
PEBL4ATSF0150 A.21 PEBN3ATAL0025 A.13 PEBN4ATSB0125 A.17 PEDB3ATEM0150 A.22 PEDC2ATGR0150 A.9 PEDC4ATGR0250 A.11
PEBL4ATSH0025 A.13 PEBN3ATAL0060 A.15 PEBN4ATSB0150 A.21 PEDB3ATEM0250 A.24 PEDC2ATGR0200 A.9 PEDC4ATSB0125 A.19
PEBL4ATSH0060 A.15 PEBN3ATAL0125 A.17 PEBN4ATSE0025 A.13 PEDB3ATGR0125 A.10 PEDC2ATGR0225 A.9 PEDC4ATSB0150 A.23
PEBL4ATSH0125 A.17 PEBN3ATAL0150 A.21 PEBN4ATSE0060 A.15 PEDB3ATGR0150 A.10 PEDC2ATGR0250 A.9 PEDC4ATSB0250 A.25
PEBL4ATSH0150 A.21 PEBN3ATAM0025 A.13 PEBN4ATSE0125 A.17 PEDB3ATGR0200 A.10 PEDC2ATSB0125 A.18 PEDC4ATSE0125 A.19
PEBL4ATTN0020 A.8 PEBN3ATAM0060 A.15 PEBN4ATSE0150 A.21 PEDB3ATGR0225 A.10 PEDC2ATSB0150 A.22 PEDC4ATSE0150 A.23
PEBL4ATTN0025 A.8 PEBN3ATAM0125 A.17 PEBN4ATSF0025 A.13 PEDB3ATGR0250 A.10 PEDC2ATSB0250 A.24 PEDC4ATSE0250 A.25
PEBL4ATTN0030 A.8 PEBN3ATAM0150 A.21 PEBN4ATSF0060 A.15 PEDB3ATSB0125 A.18 PEDC2ATSE0125 A.18 PEDC4ATSF0125 A.19
PEBL4ATTN0040 A.8 PEBN3ATEJ0025 A.13 PEBN4ATSF0125 A.17 PEDB3ATSB0150 A.22 PEDC2ATSE0150 A.22 PEDC4ATSF0150 A.23
Numerical index

PEBL4ATTN0050 A.8 PEBN3ATEJ0060 A.15 PEBN4ATSF0150 A.21 PEDB3ATSB0250 A.24 PEDC2ATSE0250 A.24 PEDC4ATSF0250 A.25
PEBL4ATTN0060 A.8 PEBN3ATEJ0125 A.17 PEBN4ATSH0025 A.13 PEDB3ATSE0125 A.18 PEDC2ATSF0125 A.18 PEDC4ATSH0125 A.19
PEBL4ATTR0070 A.8 PEBN3ATEJ0150 A.21 PEBN4ATSH0060 A.15 PEDB3ATSE0150 A.22 PEDC2ATSF0150 A.22 PEDC4ATSH0150 A.23
PEBL4ATTR0080 A.8 PEBN3ATEK0025 A.13 PEBN4ATSH0125 A.17 PEDB3ATSE0250 A.24 PEDC2ATSF0250 A.24 PEDC4ATSH0250 A.25
PEBL4ATTR0090 A.8 PEBN3ATEK0060 A.15 PEBN4ATSH0150 A.21 PEDB3ATSF0125 A.18 PEDC2ATSH0125 A.18 PEDC4ATTR0125 A.11
PEBL4ATTR0100 A.8 PEBN3ATEK0125 A.17 PEBN4ATTN0020 A.8 PEDB3ATSF0150 A.22 PEDC2ATSH0150 A.22 PEDC4ATTR0150 A.11
PEBL4ATTR0110 A.8 PEBN3ATEK0150 A.21 PEBN4ATTN0025 A.8 PEDB3ATSF0250 A.24 PEDC2ATSH0250 A.24 PEDC4ATTR0200 A.11
PEBL4ATTR0125 A.8 PEBN3ATEL0025 A.13 PEBN4ATTN0030 A.8 PEDB3ATSH0125 A.18 PEDC2ATTR0125 A.9 PEDC4ATTR0225 A.11
PEBL4ATTR0150 A.8 PEBN3ATEL0060 A.15 PEBN4ATTN0040 A.8 PEDB3ATSH0150 A.22 PEDC2ATTR0150 A.9 PEDC4ATTR0250 A.11
PEBN2ATAJ0025 A.12 PEBN3ATEL0125 A.17 PEBN4ATTN0050 A.8 PEDB3ATSH0250 A.24 PEDC2ATTR0200 A.9 PEDE2ATAJ0125 A.18
PEBN2ATAJ0060 A.14 PEBN3ATEL0150 A.21 PEBN4ATTN0060 A.8 PEDB3ATTS0125 A.10 PEDC2ATTR0225 A.9 PEDE2ATAJ0150 A.22
PEBN2ATAJ0125 A.16 PEBN3ATEM0025 A.13 PEBN4ATTR0070 A.8 PEDB3ATTS0150 A.10 PEDC2ATTR0250 A.9 PEDE2ATAJ0250 A.24
PEBN2ATAJ0150 A.20 PEBN3ATEM0060 A.15 PEBN4ATTR0080 A.8 PEDB3ATTS0200 A.10 PEDC3ATAJ0125 A.18 PEDE2ATAK0125 A.18
PEBN2ATAK0025 A.12 PEBN3ATEM0125 A.17 PEBN4ATTR0090 A.8 PEDB3ATTS0225 A.10 PEDC3ATAJ0150 A.22 PEDE2ATAK0150 A.22
PEBN2ATAK0060 A.14 PEBN3ATEM0150 A.21 PEBN4ATTR0100 A.8 PEDB3ATTS0250 A.10 PEDC3ATAJ0250 A.24 PEDE2ATAK0250 A.24
PEBN2ATAK0125 A.16 PEBN3ATGR0100 A.7 PEBN4ATTR0110 A.8 PEDB4ATAJ0125 A.19 PEDC3ATAK0125 A.18 PEDE2ATAL0125 A.18
PEBN2ATAK0150 A.20 PEBN3ATGR0110 A.7 PEBN4ATTR0125 A.8 PEDB4ATAJ0150 A.23 PEDC3ATAK0150 A.22 PEDE2ATAL0150 A.22
PEBN2ATAL0025 A.12 PEBN3ATGR0125 A.7 PEBN4ATTR0150 A.8 PEDB4ATAJ0250 A.25 PEDC3ATAK0250 A.24 PEDE2ATAL0250 A.24
Intro PEBN2ATAL0060
PEBN2ATAL0125
A.14
A.16
PEBN3ATGR0150
PEBN3ATSB0025
A.7
A.13
PEDB2ATAJ0125
PEDB2ATAJ0150
A.18
A.22
PEDB4ATAK0125
PEDB4ATAK0150
A.19
A.23
PEDC3ATAL0125
PEDC3ATAL0150
A.18
A.22
PEDE2ATAM0125
PEDE2ATAM0150
A.18
A.22
PEBN2ATAL0150 A.20 PEBN3ATSB0060 A.15 PEDB2ATAJ0250 A.24 PEDB4ATAK0250 A.25 PEDC3ATAL0250 A.24 PEDE2ATAM0250 A.24
PEBN2ATAM0025 A.12 PEBN3ATSB0125 A.17 PEDB2ATAK0125 A.18 PEDB4ATAL0125 A.19 PEDC3ATAM0125 A.18 PEDE2ATEJ0125 A.18
PEBN2ATAM0060 A.14 PEBN3ATSB0150 A.21 PEDB2ATAK0150 A.22 PEDB4ATAL0150 A.23 PEDC3ATAM0150 A.22 PEDE2ATEJ0150 A.22
A PEBN2ATAM0125
PEBN2ATAM0150
A.16
A.20
PEBN3ATSE0025
PEBN3ATSE0060
A.13
A.15
PEDB2ATAK0250
PEDB2ATAL0125
A.24
A.18
PEDB4ATAL0250
PEDB4ATAM0125
A.25
A.19
PEDC3ATAM0250
PEDC3ATEJ0125
A.24
A.18
PEDE2ATEJ0250
PEDE2ATEK0125
A.24
A.18
PEBN2ATEJ0025 A.12 PEBN3ATSE0125 A.17 PEDB2ATAL0150 A.22 PEDB4ATAM0150 A.23 PEDC3ATEJ0150 A.22 PEDE2ATEK0150 A.22
PEBN2ATEJ0060 A.14 PEBN3ATSE0150 A.21 PEDB2ATAL0250 A.24 PEDB4ATAM0250 A.25 PEDC3ATEJ0250 A.24 PEDE2ATEK0250 A.24
PEBN2ATEJ0125 A.16 PEBN3ATSF0025 A.13 PEDB2ATAM0125 A.18 PEDB4ATEJ0125 A.19 PEDC3ATEK0125 A.18 PEDE2ATEL0125 A.18
PEBN2ATEJ0150 A.20 PEBN3ATSF0060 A.15 PEDB2ATAM0150 A.22 PEDB4ATEJ0150 A.23 PEDC3ATEK0150 A.22 PEDE2ATEL0150 A.22
B PEBN2ATEJ0250
PEBN2ATEK0025
A.24
A.12
PEBN3ATSF0125
PEBN3ATSF0150
A.17
A.21
PEDB2ATAM0250
PEDB2ATEJ0125
A.24
A.18
PEDB4ATEJ0250
PEDB4ATEK0125
A.25
A.19
PEDC3ATEK0250
PEDC3ATEL0125
A.24
A.18
PEDE2ATEL0250
PEDE2ATEM0125
A.24
A.18
PEBN2ATEK0060 A.14 PEBN3ATSH0025 A.13 PEDB2ATEJ0150 A.22 PEDB4ATEK0150 A.23 PEDC3ATEL0150 A.22 PEDE2ATEM0150 A.22
PEBN2ATEK0125 A.16 PEBN3ATSH0060 A.15 PEDB2ATEJ0250 A.24 PEDB4ATEK0250 A.25 PEDC3ATEL0250 A.24 PEDE2ATEM0250 A.24
PEBN2ATEK0150 A.20 PEBN3ATSH0125 A.17 PEDB2ATEK0125 A.18 PEDB4ATEL0125 A.19 PEDC3ATEM0125 A.18 PEDE2ATGR0125 A.9
C PEBN2ATEK0250
PEBN2ATEL0025
A.24
A.12
PEBN3ATSH0150
PEBN3ATTN0020
A.21
A.7
PEDB2ATEK0150
PEDB2ATEK0250
A.22
A.24
PEDB4ATEL0150
PEDB4ATEL0250
A.23
A.25
PEDC3ATEM0150
PEDC3ATEM0250
A.22
A.24
PEDE2ATGR0150
PEDE2ATGR0200
A.9
A.9
PEBN2ATEL0060 A.14 PEBN3ATTN0025 A.7 PEDB2ATEL0125 A.18 PEDB4ATEM0125 A.19 PEDC3ATGR0125 A.10 PEDE2ATGR0225 A.9
PEBN2ATEL0125 A.16 PEBN3ATTN0030 A.7 PEDB2ATEL0150 A.22 PEDB4ATEM0150 A.23 PEDC3ATGR0150 A.10 PEDE2ATGR0250 A.9
PEBN2ATEL0150 A.20 PEBN3ATTN0040 A.7 PEDB2ATEL0250 A.24 PEDB4ATEM0250 A.25 PEDC3ATGR0200 A.10 PEDE2ATSB0125 A.18
D PEBN2ATEL0250
PEBN2ATEM0025
A.24
A.12
PEBN3ATTN0050
PEBN3ATTN0060
A.7
A.7
PEDB2ATEM0125
PEDB2ATEM0150
A.18
A.22
PEDB4ATGR0125
PEDB4ATGR0150
A.11
A.11
PEDC3ATGR0225
PEDC3ATGR0250
A.10
A.10
PEDE2ATSB0150
PEDE2ATSB0250
A.22
A.24
PEBN2ATEM0060 A.14 PEBN3ATTR0070 A.7 PEDB2ATEM0250 A.24 PEDB4ATGR0200 A.11 PEDC3ATSB0125 A.18 PEDE2ATSE0125 A.18
PEBN2ATEM0125 A.16 PEBN3ATTR0080 A.7 PEDB2ATGR0125 A.9 PEDB4ATGR0225 A.11 PEDC3ATSB0150 A.22 PEDE2ATSE0150 A.22
PEBN2ATEM0150 A.20 PEBN3ATTR0090 A.7 PEDB2ATGR0150 A.9 PEDB4ATGR0250 A.11 PEDC3ATSB0250 A.24 PEDE2ATSE0250 A.24
PEBN2ATEM0250 A.24 PEBN3ATTR0100 A.7 PEDB2ATGR0200 A.9 PEDB4ATSB0125 A.19 PEDC3ATSE0125 A.18 PEDE2ATSF0125 A.18
E PEBN2ATGR0100
PEBN2ATGR0110
A.6
A.6
PEBN3ATTR0110
PEBN3ATTR0125
A.7
A.7
PEDB2ATGR0225
PEDB2ATGR0250
A.9
A.9
PEDB4ATSB0150
PEDB4ATSB0250
A.23
A.25
PEDC3ATSE0150
PEDC3ATSE0250
A.22
A.24
PEDE2ATSF0150
PEDE2ATSF0250
A.22
A.24
PEBN2ATGR0125 A.6 PEBN3ATTR0150 A.7 PEDB2ATSB0125 A.18 PEDB4ATSE0125 A.19 PEDC3ATSF0125 A.18 PEDE2ATSH0125 A.18
PEBN2ATGR0150 A.6 PEBN4ATAJ0025 A.13 PEDB2ATSB0150 A.22 PEDB4ATSE0150 A.23 PEDC3ATSF0150 A.22 PEDE2ATSH0150 A.22
PEBN2ATSB0025 A.12 PEBN4ATAJ0060 A.15 PEDB2ATSB0250 A.24 PEDB4ATSE0250 A.25 PEDC3ATSF0250 A.24 PEDE2ATSH0250 A.24
F PEBN2ATSB0060
PEBN2ATSB0125
A.14
A.16
PEBN4ATAJ0125
PEBN4ATAJ0150
A.17
A.21
PEDB2ATSE0125
PEDB2ATSE0150
A.18
A.22
PEDB4ATSF0125
PEDB4ATSF0150
A.19
A.23
PEDC3ATSH0125
PEDC3ATSH0150
A.18
A.22
PEDE2ATTR0125
PEDE2ATTR0150
A.9
A.9
PEBN2ATSB0150 A.20 PEBN4ATAK0025 A.13 PEDB2ATSE0250 A.24 PEDB4ATSF0250 A.25 PEDC3ATSH0250 A.24 PEDE2ATTR0200 A.9
PEBN2ATSE0025 A.12 PEBN4ATAK0060 A.15 PEDB2ATSF0125 A.18 PEDB4ATSH0125 A.19 PEDC3ATTS0125 A.10 PEDE2ATTR0225 A.9
PEBN2ATSE0060 A.14 PEBN4ATAK0125 A.17 PEDB2ATSF0150 A.22 PEDB4ATSH0150 A.23 PEDC3ATTS0150 A.10 PEDE2ATTR0250 A.9
PEBN2ATSE0125 PEBN4ATAK0150 PEDB2ATSF0250 PEDB4ATSH0250 PEDC3ATTS0200 PEDE3ATAJ0125
G PEBN2ATSE0150
A.16
A.20 PEBN4ATAL0025
A.21
A.13 PEDB2ATSH0125
A.24
A.18 PEDB4ATTR0125
A.25
A.11 PEDC3ATTS0225
A.10
A.10 PEDE3ATAJ0150
A.18
A.22
PEBN2ATSF0025 A.12 PEBN4ATAL0060 A.15 PEDB2ATSH0150 A.22 PEDB4ATTR0150 A.11 PEDC3ATTS0250 A.10 PEDE3ATAJ0250 A.24
PEBN2ATSF0060 A.14 PEBN4ATAL0125 A.17 PEDB2ATSH0250 A.24 PEDB4ATTR0200 A.11 PEDC4ATAJ0125 A.19 PEDE3ATAK0125 A.18
PEBN2ATSF0125 A.16 PEBN4ATAL0150 A.21 PEDB2ATTR0125 A.9 PEDB4ATTR0225 A.11 PEDC4ATAJ0150 A.23 PEDE3ATAK0150 A.22
PEBN2ATSF0150 A.20 PEBN4ATAM0025 A.13 PEDB2ATTR0150 A.9 PEDB4ATTR0250 A.11 PEDC4ATAJ0250 A.25 PEDE3ATAK0250 A.24
X PEBN2ATSH0025
PEBN2ATSH0060
A.12
A.14
PEBN4ATAM0060
PEBN4ATAM0125
A.15
A.17
PEDB2ATTR0200
PEDB2ATTR0225
A.9
A.9
PEDC2ATAJ0125
PEDC2ATAJ0150
A.18
A.22
PEDC4ATAK0125
PEDC4ATAK0150
A.19
A.23
PEDE3ATAL0125
PEDE3ATAL0150
A.18
A.22
PEBN2ATSH0125 A.16 PEBN4ATAM0150 A.21 PEDB2ATTR0250 A.9 PEDC2ATAJ0250 A.24 PEDC4ATAK0250 A.25 PEDE3ATAL0250 A.24
PEBN2ATSH0150 A.20 PEBN4ATEJ0025 A.13 PEDB3ATAJ0125 A.18 PEDC2ATAK0125 A.18 PEDC4ATAL0125 A.19 PEDE3ATAM0125 A.18
PEBN2ATTN0020 A.6 PEBN4ATEJ0060 A.15 PEDB3ATAJ0150 A.22 PEDC2ATAK0150 A.22 PEDC4ATAL0150 A.23 PEDE3ATAM0150 A.22
PEBN2ATTN0025 A.6 PEBN4ATEJ0125 A.17 PEDB3ATAJ0250 A.24 PEDC2ATAK0250 A.24 PEDC4ATAL0250 A.25 PEDE3ATAM0250 A.24
PEBN2ATTN0030 A.6 PEBN4ATEJ0150 A.21 PEDB3ATAK0125 A.18 PEDC2ATAL0125 A.18 PEDC4ATAM0125 A.19 PEDE3ATEJ0125 A.18
PEBN2ATTN0040 A.6 PEBN4ATEK0025 A.13 PEDB3ATAK0150 A.22 PEDC2ATAL0150 A.22 PEDC4ATAM0150 A.23 PEDE3ATEJ0150 A.22
PEBN2ATTN0050 A.6 PEBN4ATEK0060 A.15 PEDB3ATAK0250 A.24 PEDC2ATAL0250 A.24 PEDC4ATAM0250 A.25 PEDE3ATEJ0250 A.24
PEBN2ATTN0060 A.6 PEBN4ATEK0125 A.17 PEDB3ATAL0125 A.18 PEDC2ATAM0125 A.18 PEDC4ATEJ0125 A.19 PEDE3ATEK0125 A.18
PEBN2ATTR0070 A.6 PEBN4ATEK0150 A.21 PEDB3ATAL0150 A.22 PEDC2ATAM0150 A.22 PEDC4ATEJ0150 A.23 PEDE3ATEK0150 A.22
PEBN2ATTR0080 A.6 PEBN4ATEL0025 A.13 PEDB3ATAL0250 A.24 PEDC2ATAM0250 A.24 PEDC4ATEJ0250 A.25 PEDE3ATEK0250 A.24
PEBN2ATTR0090 A.6 PEBN4ATEL0060 A.15 PEDB3ATAM0125 A.18 PEDC2ATEJ0125 A.18 PEDC4ATEK0125 A.19 PEDE3ATEL0125 A.18
PEBN2ATTR0100 A.6 PEBN4ATEL0125 A.17 PEDB3ATAM0150 A.22 PEDC2ATEJ0150 A.22 PEDC4ATEK0150 A.23 PEDE3ATEL0150 A.22
PEBN2ATTR0110 A.6 PEBN4ATEL0150 A.21 PEDB3ATAM0250 A.24 PEDC2ATEJ0250 A.24 PEDC4ATEK0250 A.25 PEDE3ATEL0250 A.24
PEBN2ATTR0125 A.6 PEBN4ATEM0025 A.13 PEDB3ATEJ0125 A.18 PEDC2ATEK0125 A.18 PEDC4ATEL0125 A.19 PEDE3ATEM0125 A.18

X.6
GuardEon
Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page
PEDE3ATEM0150 A.22 PEDH2ATGR0150 A.9 PEDH4ATGR0250 A.11 PEDL3ATSB0250 A.24 PEDN2ATSE0250 A.24 PEDN4ATSF0250 A.25
PEDE3ATEM0250 A.24 PEDH2ATGR0200 A.9 PEDH4ATSB0125 A.19 PEDL3ATSE0125 A.18 PEDN2ATSF0125 A.18 PEDN4ATSH0125 A.19
PEDE3ATGR0125 A.10 PEDH2ATGR0225 A.9 PEDH4ATSB0150 A.23 PEDL3ATSE0150 A.22 PEDN2ATSF0150 A.22 PEDN4ATSH0150 A.23
PEDE3ATGR0150 A.10 PEDH2ATGR0250 A.9 PEDH4ATSB0250 A.25 PEDL3ATSE0250 A.24 PEDN2ATSF0250 A.24 PEDN4ATSH0250 A.25
PEDE3ATGR0200 A.10 PEDH2ATSB0125 A.18 PEDH4ATSE0125 A.19 PEDL3ATSF0125 A.18 PEDN2ATSH0125 A.18 PEDN4ATTR0125 A.11
PEDE3ATGR0225 A.10 PEDH2ATSB0150 A.22 PEDH4ATSE0150 A.23 PEDL3ATSF0150 A.22 PEDN2ATSH0150 A.22 PEDN4ATTR0150 A.11
PEDE3ATGR0250 A.10 PEDH2ATSB0250 A.24 PEDH4ATSE0250 A.25 PEDL3ATSF0250 A.24 PEDN2ATSH0250 A.24 PEDN4ATTR0200 A.11
PEDE3ATSB0125 A.18 PEDH2ATSE0125 A.18 PEDH4ATSF0125 A.19 PEDL3ATSH0125 A.18 PEDN2ATTR0125 A.9 PEDN4ATTR0225 A.11
PEDE3ATSB0150 A.22 PEDH2ATSE0150 A.22 PEDH4ATSF0150 A.23 PEDL3ATSH0150 A.22 PEDN2ATTR0150 A.9 PEDN4ATTR0250 A.11
PEDE3ATSB0250 A.24 PEDH2ATSE0250 A.24 PEDH4ATSF0250 A.25 PEDL3ATSH0250 A.24 PEDN2ATTR0200 A.9 PEEB2ATAJ0125 A.18
PEDE3ATSE0125 A.18 PEDH2ATSF0125 A.18 PEDH4ATSH0125 A.19 PEDL3ATTS0125 A.10 PEDN2ATTR0225 A.9 PEEB2ATAJ0150 A.22
PEDE3ATSE0150 A.22 PEDH2ATSF0150 A.22 PEDH4ATSH0150 A.23 PEDL3ATTS0150 A.10 PEDN2ATTR0250 A.9 PEEB2ATAJ0250 A.24
PEDE3ATSE0250 A.24 PEDH2ATSF0250 A.24 PEDH4ATSH0250 A.25 PEDL3ATTS0200 A.10 PEDN3ATAJ0125 A.18 PEEB2ATAK0125 A.18
PEDE3ATSF0125 A.18 PEDH2ATSH0125 A.18 PEDH4ATTR0125 A.11 PEDL3ATTS0225 A.10 PEDN3ATAJ0150 A.22 PEEB2ATAK0150 A.22

By catalogue number
PEDE3ATSF0150 A.22 PEDH2ATSH0150 A.22 PEDH4ATTR0150 A.11 PEDL3ATTS0250 A.10 PEDN3ATAJ0250 A.24 PEEB2ATAK0250 A.24
PEDE3ATSF0250 A.24 PEDH2ATSH0250 A.24 PEDH4ATTR0200 A.11 PEDL4ATAJ0125 A.19 PEDN3ATAK0125 A.18 PEEB2ATAL0125 A.18
PEDE3ATSH0125 A.18 PEDH2ATTR0125 A.9 PEDH4ATTR0225 A.11 PEDL4ATAJ0150 A.23 PEDN3ATAK0150 A.22 PEEB2ATAL0150 A.22
PEDE3ATSH0150 A.22 PEDH2ATTR0150 A.9 PEDH4ATTR0250 A.11 PEDL4ATAJ0250 A.25 PEDN3ATAK0250 A.24 PEEB2ATAL0250 A.24
PEDE3ATSH0250 A.24 PEDH2ATTR0200 A.9 PEDL2ATAJ0125 A.18 PEDL4ATAK0125 A.19 PEDN3ATAL0125 A.18 PEEB2ATAM0125 A.18
PEDE3ATTS0125 A.10 PEDH2ATTR0225 A.9 PEDL2ATAJ0150 A.22 PEDL4ATAK0150 A.23 PEDN3ATAL0150 A.22 PEEB2ATAM0150 A.22
PEDE3ATTS0150 A.10 PEDH2ATTR0250 A.9 PEDL2ATAJ0250 A.24 PEDL4ATAK0250 A.25 PEDN3ATAL0250 A.24 PEEB2ATAM0250 A.24
PEDE3ATTS0200 A.10 PEDH3ATAJ0125 A.18 PEDL2ATAK0125 A.18 PEDL4ATAL0125 A.19 PEDN3ATAM0125 A.18 PEEB2ATEJ0125 A.18
PEDE3ATTS0225 A.10 PEDH3ATAJ0150 A.22 PEDL2ATAK0150 A.22 PEDL4ATAL0150 A.23 PEDN3ATAM0150 A.22 PEEB2ATEJ0150 A.22
PEDE3ATTS0250 A.10 PEDH3ATAJ0250 A.24 PEDL2ATAK0250 A.24 PEDL4ATAL0250 A.25 PEDN3ATAM0250 A.24 PEEB2ATEK0125 A.18
PEDE4ATAJ0125 A.19 PEDH3ATAK0125 A.18 PEDL2ATAL0125 A.18 PEDL4ATAM0125 A.19 PEDN3ATEJ0125 A.18 PEEB2ATEK0150 A.22
PEDE4ATAJ0150 A.23 PEDH3ATAK0150 A.22 PEDL2ATAL0150 A.22 PEDL4ATAM0150 A.23 PEDN3ATEJ0150 A.22 PEEB2ATEL0125 A.18
PEDE4ATAJ0250 A.25 PEDH3ATAK0250 A.24 PEDL2ATAL0250 A.24 PEDL4ATAM0250 A.25 PEDN3ATEJ0250 A.24 PEEB2ATEL0150 A.22
PEDE4ATAK0125 A.19 PEDH3ATAL0125 A.18 PEDL2ATAM0125 A.18 PEDL4ATEJ0125 A.19 PEDN3ATEK0125 A.18 PEEB2ATEM0125 A.18
PEDE4ATAK0150 A.23 PEDH3ATAL0150 A.22 PEDL2ATAM0150 A.22 PEDL4ATEJ0150 A.23 PEDN3ATEK0150 A.22 PEEB2ATEM0150 A.22
PEDE4ATAK0250 A.25 PEDH3ATAL0250 A.24 PEDL2ATAM0250 A.24 PEDL4ATEJ0250 A.25 PEDN3ATEK0250 A.24 PEEB2ATGS0125 A.9
PEDE4ATAL0125 A.19 PEDH3ATAM0125 A.18 PEDL2ATEJ0125 A.18 PEDL4ATEK0125 A.19 PEDN3ATEL0125 A.18 PEEB2ATGS0150 A.9
PEDE4ATAL0150 A.23 PEDH3ATAM0150 A.22 PEDL2ATEJ0150 A.22 PEDL4ATEK0150 A.23 PEDN3ATEL0150 A.22 PEEB2ATGS0200 A.9
PEDE4ATAL0250 A.25 PEDH3ATAM0250 A.24 PEDL2ATEJ0250 A.24 PEDL4ATEK0250 A.25 PEDN3ATEL0250 A.24 PEEB2ATGS0225 A.9
PEDE4ATAM0125 A.19 PEDH3ATEJ0125 A.18 PEDL2ATEK0125 A.18 PEDL4ATEL0125 A.19 PEDN3ATEM0125 A.18 PEEB2ATGS0250 A.9
PEDE4ATAM0150 A.23 PEDH3ATEJ0150 A.22 PEDL2ATEK0150 A.22 PEDL4ATEL0150 A.23 PEDN3ATEM0150 A.22 PEEB2ATSB0125 A.18
PEDE4ATAM0250 A.25 PEDH3ATEJ0250 A.24 PEDL2ATEK0250 A.24 PEDL4ATEL0250 A.25 PEDN3ATEM0250 A.24 PEEB2ATSB0150 A.22
PEDE4ATEJ0125
PEDE4ATEJ0150
A.19
A.23
PEDH3ATEK0125
PEDH3ATEK0150
A.18
A.22
PEDL2ATEL0125
PEDL2ATEL0150
A.18
A.22
PEDL4ATEM0125
PEDL4ATEM0150
A.19
A.23
PEDN3ATGR0125
PEDN3ATGR0150
A.10
A.10
PEEB2ATSB0250
PEEB2ATSE0125
A.24
A.18
Intro
PEDE4ATEJ0250 A.25 PEDH3ATEK0250 A.24 PEDL2ATEL0250 A.24 PEDL4ATEM0250 A.25 PEDN3ATGR0200 A.10 PEEB2ATSE0150 A.22
PEDE4ATEK0125 A.19 PEDH3ATEL0125 A.18 PEDL2ATEM0125 A.18 PEDL4ATGR0125 A.11 PEDN3ATGR0225 A.10 PEEB2ATSE0250 A.24
PEDE4ATEK0150 A.23 PEDH3ATEL0150 A.22 PEDL2ATEM0150 A.22 PEDL4ATGR0150 A.11 PEDN3ATGR0250 A.10 PEEB2ATSF0125 A.18
PEDE4ATEK0250
PEDE4ATEL0125
A.25
A.19
PEDH3ATEL0250
PEDH3ATEM0125
A.24
A.18
PEDL2ATEM0250
PEDL2ATGR0125
A.24
A.9
PEDL4ATGR0200
PEDL4ATGR0225
A.11
A.11
PEDN3ATSB0125
PEDN3ATSB0150
A.18
A.22
PEEB2ATSF0150
PEEB2ATSF0250
A.22
A.24 A
PEDE4ATEL0150 A.23 PEDH3ATEM0150 A.22 PEDL2ATGR0150 A.9 PEDL4ATGR0250 A.11 PEDN3ATSB0250 A.24 PEEB2ATSH0125 A.18
PEDE4ATEL0250 A.25 PEDH3ATEM0250 A.24 PEDL2ATGR0200 A.9 PEDL4ATSB0125 A.19 PEDN3ATSE0125 A.18 PEEB2ATSH0150 A.22
PEDE4ATEM0125 A.19 PEDH3ATGR0125 A.10 PEDL2ATGR0225 A.9 PEDL4ATSB0150 A.23 PEDN3ATSE0150 A.22 PEEB2ATSH0250 A.24
PEDE4ATEM0150 A.23 PEDH3ATGR0150 A.10 PEDL2ATGR0250 A.9 PEDL4ATSB0250 A.25 PEDN3ATSE0250 A.24 PEEB2ATTR0125 A.9
PEDE4ATEM0250
PEDE4ATGR0125
A.25
A.11
PEDH3ATGR0200
PEDH3ATGR0225
A.10
A.10
PEDL2ATSB0125
PEDL2ATSB0150
A.18
A.22
PEDL4ATSE0125
PEDL4ATSE0150
A.19
A.23
PEDN3ATSF0125
PEDN3ATSF0150
A.18
A.22
PEEB2ATTR0150
PEEB2ATTR0200
A.9
A.9
B
PEDE4ATGR0150 A.11 PEDH3ATGR0250 A.10 PEDL2ATSB0250 A.24 PEDL4ATSE0250 A.25 PEDN3ATSF0250 A.24 PEEB2ATTR0225 A.9
PEDE4ATGR0200 A.11 PEDH3ATSB0125 A.18 PEDL2ATSE0125 A.18 PEDL4ATSF0125 A.19 PEDN3ATSH0125 A.18 PEEB2ATTR0250 A.9
PEDE4ATGR0225 A.11 PEDH3ATSB0150 A.22 PEDL2ATSE0150 A.22 PEDL4ATSF0150 A.23 PEDN3ATSH0150 A.22 PEEB3ATAJ0125 A.19
PEDE4ATGR0250
PEDE4ATSB0125
A.11
A.19
PEDH3ATSB0250
PEDH3ATSE0125
A.24
A.18
PEDL2ATSE0250
PEDL2ATSF0125
A.24
A.18
PEDL4ATSF0250
PEDL4ATSH0125
A.25
A.19
PEDN3ATSH0250
PEDN3ATTS0125
A.24
A.10
PEEB3ATAJ0150
PEEB3ATAJ0250
A.23
A.25
C
PEDE4ATSB0150 A.23 PEDH3ATSE0150 A.22 PEDL2ATSF0150 A.22 PEDL4ATSH0150 A.23 PEDN3ATTS0150 A.10 PEEB3ATAK0125 A.19
PEDE4ATSB0250 A.25 PEDH3ATSE0250 A.24 PEDL2ATSF0250 A.24 PEDL4ATSH0250 A.25 PEDN3ATTS0200 A.10 PEEB3ATAK0150 A.23
PEDE4ATSE0125 A.19 PEDH3ATSF0125 A.18 PEDL2ATSH0125 A.18 PEDL4ATTR0125 A.11 PEDN3ATTS0225 A.10 PEEB3ATAK0250 A.25
PEDE4ATSE0150
PEDE4ATSE0250
A.23
A.25
PEDH3ATSF0150
PEDH3ATSF0250
A.22
A.24
PEDL2ATSH0150
PEDL2ATSH0250
A.22
A.24
PEDL4ATTR0150
PEDL4ATTR0200
A.11
A.11
PEDN3ATTS0250
PEDN4ATAJ0125
A.10
A.19
PEEB3ATAL0125
PEEB3ATAL0150
A.19
A.23 D
PEDE4ATSF0125 A.19 PEDH3ATSH0125 A.18 PEDL2ATTR0125 A.9 PEDL4ATTR0225 A.11 PEDN4ATAJ0150 A.23 PEEB3ATAL0250 A.25
PEDE4ATSF0150 A.23 PEDH3ATSH0150 A.22 PEDL2ATTR0150 A.9 PEDL4ATTR0250 A.11 PEDN4ATAJ0250 A.25 PEEB3ATAM0125 A.19
PEDE4ATSF0250 A.25 PEDH3ATSH0250 A.24 PEDL2ATTR0200 A.9 PEDN2ATAJ0125 A.18 PEDN4ATAK0125 A.19 PEEB3ATAM0150 A.23
PEDE4ATSH0125 A.19 PEDH3ATTS0125 A.10 PEDL2ATTR0225 A.9 PEDN2ATAJ0150 A.22 PEDN4ATAK0150 A.23 PEEB3ATAM0250 A.25
PEDE4ATSH0150
PEDE4ATSH0250
A.23
A.25
PEDH3ATTS0150
PEDH3ATTS0200
A.10
A.10
PEDL2ATTR0250
PEDL3ATAJ0125
A.9
A.18
PEDN2ATAJ0250
PEDN2ATAK0125
A.24
A.18
PEDN4ATAK0250
PEDN4ATAL0125
A.25
A.19
PEEB3ATEJ0125
PEEB3ATEJ0150
A.19
A.23
E
PEDE4ATTR0125 A.11 PEDH3ATTS0225 A.10 PEDL3ATAJ0150 A.22 PEDN2ATAK0150 A.22 PEDN4ATAL0150 A.23 PEEB3ATEJ0250 A.25
PEDE4ATTR0150 A.11 PEDH3ATTS0250 A.10 PEDL3ATAJ0250 A.24 PEDN2ATAK0250 A.24 PEDN4ATAL0250 A.25 PEEB3ATEK0125 A.19
PEDE4ATTR0200 A.11 PEDH4ATAJ0125 A.19 PEDL3ATAK0125 A.18 PEDN2ATAL0125 A.18 PEDN4ATAM0125 A.19 PEEB3ATEK0150 A.23
PEDE4ATTR0225
PEDE4ATTR0250
A.11
A.11
PEDH4ATAJ0150
PEDH4ATAJ0250
A.23
A.25
PEDL3ATAK0150
PEDL3ATAK0250
A.22
A.24
PEDN2ATAL0150
PEDN2ATAL0250
A.22
A.24
PEDN4ATAM0150
PEDN4ATAM0250
A.23
A.25
PEEB3ATEK0250
PEEB3ATEL0125
A.25
A.19 F
PEDH2ATAJ0125 A.18 PEDH4ATAK0125 A.19 PEDL3ATAL0125 A.18 PEDN2ATAM0125 A.18 PEDN4ATEJ0125 A.19 PEEB3ATEL0150 A.23
PEDH2ATAJ0150 A.22 PEDH4ATAK0150 A.23 PEDL3ATAL0150 A.22 PEDN2ATAM0150 A.22 PEDN4ATEJ0150 A.23 PEEB3ATEL0250 A.25
PEDH2ATAJ0250 A.24 PEDH4ATAK0250 A.25 PEDL3ATAL0250 A.24 PEDN2ATAM0250 A.24 PEDN4ATEJ0250 A.25 PEEB3ATEM0125 A.19
PEDH2ATAK0125 PEDH4ATAL0125 PEDL3ATAM0125 PEDN2ATEJ0125 PEDN4ATEK0125 PEEB3ATEM0150
PEDH2ATAK0150
A.18
A.22 PEDH4ATAL0150
A.19
A.23 PEDL3ATAM0150
A.18
A.22 PEDN2ATEJ0150
A.18
A.22 PEDN4ATEK0150
A.19
A.23 PEEB3ATEM0250
A.23
A.25 G
PEDH2ATAK0250 A.24 PEDH4ATAL0250 A.25 PEDL3ATAM0250 A.24 PEDN2ATEJ0250 A.24 PEDN4ATEK0250 A.25 PEEB3ATGR0125 A.10
PEDH2ATAL0125 A.18 PEDH4ATAM0125 A.19 PEDL3ATEJ0125 A.18 PEDN2ATEK0125 A.18 PEDN4ATEL0125 A.19 PEEB3ATGR0150 A.10
PEDH2ATAL0150 A.22 PEDH4ATAM0150 A.23 PEDL3ATEJ0150 A.22 PEDN2ATEK0150 A.22 PEDN4ATEL0150 A.23 PEEB3ATGR0200 A.10
PEDH2ATAL0250 A.24 PEDH4ATAM0250 A.25 PEDL3ATEJ0250 A.24 PEDN2ATEK0250 A.24 PEDN4ATEL0250 A.25 PEEB3ATGR0225 A.10
PEDH2ATAM0125
PEDH2ATAM0150
A.18
A.22
PEDH4ATEJ0125
PEDH4ATEJ0150
A.19
A.23
PEDL3ATEK0125
PEDL3ATEK0150
A.18
A.22
PEDN2ATEL0125
PEDN2ATEL0150
A.18
A.22
PEDN4ATEM0125
PEDN4ATEM0150
A.19
A.23
PEEB3ATGR0250
PEEB3ATSB0125
A.10
A.19
X
PEDH2ATAM0250 A.24 PEDH4ATEJ0250 A.25 PEDL3ATEK0250 A.24 PEDN2ATEL0250 A.24 PEDN4ATEM0250 A.25 PEEB3ATSB0150 A.23
PEDH2ATEJ0125 A.18 PEDH4ATEK0125 A.19 PEDL3ATEL0125 A.18 PEDN2ATEM0125 A.18 PEDN4ATGR0125 A.11 PEEB3ATSB0250 A.25
PEDH2ATEJ0150 A.22 PEDH4ATEK0150 A.23 PEDL3ATEL0150 A.22 PEDN2ATEM0150 A.22 PEDN4ATGR0150 A.11 PEEB3ATSE0125 A.19
PEDH2ATEJ0250 A.24 PEDH4ATEK0250 A.25 PEDL3ATEL0250 A.24 PEDN2ATEM0250 A.24 PEDN4ATGR0200 A.11 PEEB3ATSE0150 A.23
PEDH2ATEK0125 A.18 PEDH4ATEL0125 A.19 PEDL3ATEM0125 A.18 PEDN2ATGR0125 A.9 PEDN4ATGR0225 A.11 PEEB3ATSE0250 A.25
PEDH2ATEK0150 A.22 PEDH4ATEL0150 A.23 PEDL3ATEM0150 A.22 PEDN2ATGR0150 A.9 PEDN4ATGR0250 A.11 PEEB3ATSF0125 A.19
PEDH2ATEK0250 A.24 PEDH4ATEL0250 A.25 PEDL3ATEM0250 A.24 PEDN2ATGR0200 A.9 PEDN4ATSB0125 A.19 PEEB3ATSF0150 A.23
PEDH2ATEL0125 A.18 PEDH4ATEM0125 A.19 PEDL3ATGR0125 A.10 PEDN2ATGR0225 A.9 PEDN4ATSB0150 A.23 PEEB3ATSF0250 A.25
PEDH2ATEL0150 A.22 PEDH4ATEM0150 A.23 PEDL3ATGR0150 A.10 PEDN2ATGR0250 A.9 PEDN4ATSB0250 A.25 PEEB3ATSH0125 A.19
PEDH2ATEL0250 A.24 PEDH4ATEM0250 A.25 PEDL3ATGR0200 A.10 PEDN2ATSB0125 A.18 PEDN4ATSE0125 A.19 PEEB3ATSH0150 A.23
PEDH2ATEM0125 A.18 PEDH4ATGR0125 A.11 PEDL3ATGR0225 A.10 PEDN2ATSB0150 A.22 PEDN4ATSE0150 A.23 PEEB3ATSH0250 A.25
PEDH2ATEM0150 A.22 PEDH4ATGR0150 A.11 PEDL3ATGR0250 A.10 PEDN2ATSB0250 A.24 PEDN4ATSE0250 A.25 PEEB3ATTS0125 A.10
PEDH2ATEM0250 A.24 PEDH4ATGR0200 A.11 PEDL3ATSB0125 A.18 PEDN2ATSE0125 A.18 PEDN4ATSF0125 A.19 PEEB3ATTS0150 A.10
PEDH2ATGR0125 A.9 PEDH4ATGR0225 A.11 PEDL3ATSB0150 A.22 PEDN2ATSE0150 A.22 PEDN4ATSF0150 A.23 PEEB3ATTS0200 A.10

X.7
GuardEon
Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page
PEEB3ATTS0225 A.10 PEEC3ATAK0250 A.25 PEEE2ATAL0250 A.24 PEEE4ATEK0125 A.19 PEEH3ATEM0150 A.23 PEEL2ATSB0125 A.18
PEEB3ATTS0250 A.10 PEEC3ATAL0125 A.19 PEEE2ATAM0125 A.18 PEEE4ATEK0150 A.23 PEEH3ATEM0250 A.25 PEEL2ATSB0150 A.22
PEEB4ATAJ0125 A.19 PEEC3ATAL0150 A.23 PEEE2ATAM0150 A.22 PEEE4ATEK0250 A.25 PEEH3ATGR0125 A.10 PEEL2ATSB0250 A.24
PEEB4ATAJ0150 A.23 PEEC3ATAL0250 A.25 PEEE2ATAM0250 A.24 PEEE4ATEL0125 A.19 PEEH3ATGR0150 A.10 PEEL2ATSE0125 A.18
PEEB4ATAJ0250 A.25 PEEC3ATAM0125 A.19 PEEE2ATEJ0125 A.18 PEEE4ATEL0150 A.23 PEEH3ATGR0200 A.10 PEEL2ATSE0150 A.22
PEEB4ATAK0125 A.19 PEEC3ATAM0150 A.23 PEEE2ATEJ0150 A.22 PEEE4ATEL0250 A.25 PEEH3ATGR0225 A.10 PEEL2ATSE0250 A.24
PEEB4ATAK0150 A.23 PEEC3ATAM0250 A.25 PEEE2ATEK0125 A.18 PEEE4ATEM0125 A.19 PEEH3ATGR0250 A.10 PEEL2ATSF0125 A.18
PEEB4ATAK0250 A.25 PEEC3ATEJ0125 A.19 PEEE2ATEK0150 A.22 PEEE4ATEM0150 A.23 PEEH3ATSB0125 A.19 PEEL2ATSF0150 A.22
PEEB4ATAL0125 A.19 PEEC3ATEJ0150 A.23 PEEE2ATEL0125 A.18 PEEE4ATEM0250 A.25 PEEH3ATSB0150 A.23 PEEL2ATSF0250 A.24
PEEB4ATAL0150 A.23 PEEC3ATEJ0250 A.25 PEEE2ATEL0150 A.22 PEEE4ATGR0125 A.11 PEEH3ATSB0250 A.25 PEEL2ATSH0125 A.18
PEEB4ATAL0250 A.25 PEEC3ATEK0125 A.19 PEEE2ATEM0125 A.18 PEEE4ATGR0150 A.11 PEEH3ATSE0125 A.19 PEEL2ATSH0150 A.22
PEEB4ATAM0125 A.19 PEEC3ATEK0150 A.23 PEEE2ATEM0150 A.22 PEEE4ATGR0200 A.11 PEEH3ATSE0150 A.23 PEEL2ATSH0250 A.24
PEEB4ATAM0150 A.23 PEEC3ATEK0250 A.25 PEEE2ATGS0125 A.9 PEEE4ATGR0225 A.11 PEEH3ATSE0250 A.25 PEEL2ATTR0125 A.9
PEEB4ATAM0250 A.25 PEEC3ATEL0125 A.19 PEEE2ATGS0150 A.9 PEEE4ATGR0250 A.11 PEEH3ATSF0125 A.19 PEEL2ATTR0150 A.9
PEEB4ATEJ0125 A.19 PEEC3ATEL0150 A.23 PEEE2ATGS0200 A.9 PEEE4ATSB0125 A.19 PEEH3ATSF0150 A.23 PEEL2ATTR0200 A.9
PEEB4ATEJ0150 A.23 PEEC3ATEL0250 A.25 PEEE2ATGS0225 A.9 PEEE4ATSB0150 A.23 PEEH3ATSF0250 A.25 PEEL2ATTR0225 A.9
PEEB4ATEJ0250 A.25 PEEC3ATEM0125 A.19 PEEE2ATGS0250 A.9 PEEE4ATSB0250 A.25 PEEH3ATSH0125 A.19 PEEL2ATTR0250 A.9
PEEB4ATEK0125 A.19 PEEC3ATEM0150 A.23 PEEE2ATSB0125 A.18 PEEE4ATSE0125 A.19 PEEH3ATSH0150 A.23 PEEL3ATAJ0125 A.19
Numerical index

PEEB4ATEK0150 A.23 PEEC3ATEM0250 A.25 PEEE2ATSB0150 A.22 PEEE4ATSE0150 A.23 PEEH3ATSH0250 A.25 PEEL3ATAJ0150 A.23
PEEB4ATEK0250 A.25 PEEC3ATGR0125 A.10 PEEE2ATSB0250 A.24 PEEE4ATSE0250 A.25 PEEH3ATTS0125 A.10 PEEL3ATAJ0250 A.25
PEEB4ATEL0125 A.19 PEEC3ATGR0150 A.10 PEEE2ATSE0125 A.18 PEEE4ATSF0125 A.19 PEEH3ATTS0150 A.10 PEEL3ATAK0125 A.19
PEEB4ATEL0150 A.23 PEEC3ATGR0200 A.10 PEEE2ATSE0150 A.22 PEEE4ATSF0150 A.23 PEEH3ATTS0200 A.10 PEEL3ATAK0150 A.23
PEEB4ATEL0250 A.25 PEEC3ATGR0225 A.10 PEEE2ATSE0250 A.24 PEEE4ATSF0250 A.25 PEEH3ATTS0225 A.10 PEEL3ATAK0250 A.25
PEEB4ATEM0125 A.19 PEEC3ATGR0250 A.10 PEEE2ATSF0125 A.18 PEEE4ATSH0125 A.19 PEEH3ATTS0250 A.10 PEEL3ATAL0125 A.19
PEEB4ATEM0150 A.23 PEEC3ATSB0125 A.19 PEEE2ATSF0150 A.22 PEEE4ATSH0150 A.23 PEEH4ATAJ0125 A.19 PEEL3ATAL0150 A.23
PEEB4ATEM0250 A.25 PEEC3ATSB0150 A.23 PEEE2ATSF0250 A.24 PEEE4ATSH0250 A.25 PEEH4ATAJ0150 A.23 PEEL3ATAL0250 A.25
PEEB4ATGR0125 A.11 PEEC3ATSB0250 A.25 PEEE2ATSH0125 A.18 PEEE4ATTR0125 A.11 PEEH4ATAJ0250 A.25 PEEL3ATAM0125 A.19
PEEB4ATGR0150 A.11 PEEC3ATSE0125 A.19 PEEE2ATSH0150 A.22 PEEE4ATTR0150 A.11 PEEH4ATAK0125 A.19 PEEL3ATAM0150 A.23
PEEB4ATGR0200 A.11 PEEC3ATSE0150 A.23 PEEE2ATSH0250 A.24 PEEE4ATTR0200 A.11 PEEH4ATAK0150 A.23 PEEL3ATAM0250 A.25
PEEB4ATGR0225 A.11 PEEC3ATSE0250 A.25 PEEE2ATTR0125 A.9 PEEE4ATTR0225 A.11 PEEH4ATAK0250 A.25 PEEL3ATEJ0125 A.19
PEEB4ATGR0250 A.11 PEEC3ATSF0125 A.19 PEEE2ATTR0150 A.9 PEEE4ATTR0250 A.11 PEEH4ATAL0125 A.19 PEEL3ATEJ0150 A.23
PEEB4ATSB0125 A.19 PEEC3ATSF0150 A.23 PEEE2ATTR0200 A.9 PEEH2ATAJ0125 A.18 PEEH4ATAL0150 A.23 PEEL3ATEJ0250 A.25
PEEB4ATSB0150 A.23 PEEC3ATSF0250 A.25 PEEE2ATTR0225 A.9 PEEH2ATAJ0150 A.22 PEEH4ATAL0250 A.25 PEEL3ATEK0125 A.19
PEEB4ATSB0250 A.25 PEEC3ATSH0125 A.19 PEEE2ATTR0250 A.9 PEEH2ATAJ0250 A.24 PEEH4ATAM0125 A.19 PEEL3ATEK0150 A.23
PEEB4ATSE0125 A.19 PEEC3ATSH0150 A.23 PEEE3ATAJ0125 A.19 PEEH2ATAK0125 A.18 PEEH4ATAM0150 A.23 PEEL3ATEK0250 A.25
PEEB4ATSE0150 A.23 PEEC3ATSH0250 A.25 PEEE3ATAJ0150 A.23 PEEH2ATAK0150 A.22 PEEH4ATAM0250 A.25 PEEL3ATEL0125 A.19
Intro PEEB4ATSE0250
PEEB4ATSF0125
A.25
A.19
PEEC3ATTS0125
PEEC3ATTS0150
A.10
A.10
PEEE3ATAJ0250
PEEE3ATAK0125
A.25
A.19
PEEH2ATAK0250
PEEH2ATAL0125
A.24
A.18
PEEH4ATEJ0125
PEEH4ATEJ0150
A.19
A.23
PEEL3ATEL0150
PEEL3ATEL0250
A.23
A.25
PEEB4ATSF0150 A.23 PEEC3ATTS0200 A.10 PEEE3ATAK0150 A.23 PEEH2ATAL0150 A.22 PEEH4ATEJ0250 A.25 PEEL3ATEM0125 A.19
PEEB4ATSF0250 A.25 PEEC3ATTS0225 A.10 PEEE3ATAK0250 A.25 PEEH2ATAL0250 A.24 PEEH4ATEK0125 A.19 PEEL3ATEM0150 A.23
PEEB4ATSH0125 A.19 PEEC3ATTS0250 A.10 PEEE3ATAL0125 A.19 PEEH2ATAM0125 A.18 PEEH4ATEK0150 A.23 PEEL3ATEM0250 A.25
A PEEB4ATSH0150
PEEB4ATSH0250
A.23
A.25
PEEC4ATAJ0125
PEEC4ATAJ0150
A.19
A.23
PEEE3ATAL0150
PEEE3ATAL0250
A.23
A.25
PEEH2ATAM0150
PEEH2ATAM0250
A.22
A.24
PEEH4ATEK0250
PEEH4ATEL0125
A.25
A.19
PEEL3ATGR0125
PEEL3ATGR0150
A.10
A.10
PEEB4ATTR0125 A.11 PEEC4ATAJ0250 A.25 PEEE3ATAM0125 A.19 PEEH2ATEJ0125 A.18 PEEH4ATEL0150 A.23 PEEL3ATGR0200 A.10
PEEB4ATTR0150 A.11 PEEC4ATAK0125 A.19 PEEE3ATAM0150 A.23 PEEH2ATEJ0150 A.22 PEEH4ATEL0250 A.25 PEEL3ATGR0225 A.10
PEEB4ATTR0200 A.11 PEEC4ATAK0150 A.23 PEEE3ATAM0250 A.25 PEEH2ATEK0125 A.18 PEEH4ATEM0125 A.19 PEEL3ATGR0250 A.10
PEEB4ATTR0225 A.11 PEEC4ATAK0250 A.25 PEEE3ATEJ0125 A.19 PEEH2ATEK0150 A.22 PEEH4ATEM0150 A.23 PEEL3ATSB0125 A.19
B PEEB4ATTR0250
PEEC2ATAJ0125
A.11
A.18
PEEC4ATAL0125
PEEC4ATAL0150
A.19
A.23
PEEE3ATEJ0150
PEEE3ATEJ0250
A.23
A.25
PEEH2ATEL0125
PEEH2ATEL0150
A.18
A.22
PEEH4ATEM0250
PEEH4ATGR0125
A.25
A.11
PEEL3ATSB0150
PEEL3ATSB0250
A.23
A.25
PEEC2ATAJ0150 A.22 PEEC4ATAL0250 A.25 PEEE3ATEK0125 A.19 PEEH2ATEM0125 A.18 PEEH4ATGR0150 A.11 PEEL3ATSE0125 A.19
PEEC2ATAJ0250 A.24 PEEC4ATAM0125 A.19 PEEE3ATEK0150 A.23 PEEH2ATEM0150 A.22 PEEH4ATGR0200 A.11 PEEL3ATSE0150 A.23
PEEC2ATAK0125 A.18 PEEC4ATAM0150 A.23 PEEE3ATEK0250 A.25 PEEH2ATGS0125 A.9 PEEH4ATGR0225 A.11 PEEL3ATSE0250 A.25
C PEEC2ATAK0150
PEEC2ATAK0250
A.22
A.24
PEEC4ATAM0250
PEEC4ATEJ0125
A.25
A.19
PEEE3ATEL0125
PEEE3ATEL0150
A.19
A.23
PEEH2ATGS0150
PEEH2ATGS0200
A.9
A.9
PEEH4ATGR0250
PEEH4ATSB0125
A.11
A.19
PEEL3ATSF0125
PEEL3ATSF0150
A.19
A.23
PEEC2ATAL0125 A.18 PEEC4ATEJ0150 A.23 PEEE3ATEL0250 A.25 PEEH2ATGS0225 A.9 PEEH4ATSB0150 A.23 PEEL3ATSF0250 A.25
PEEC2ATAL0150 A.22 PEEC4ATEJ0250 A.25 PEEE3ATEM0125 A.19 PEEH2ATGS0250 A.9 PEEH4ATSB0250 A.25 PEEL3ATSH0125 A.19
PEEC2ATAL0250 A.24 PEEC4ATEK0125 A.19 PEEE3ATEM0150 A.23 PEEH2ATSB0125 A.18 PEEH4ATSE0125 A.19 PEEL3ATSH0150 A.23
D PEEC2ATAM0125
PEEC2ATAM0150
A.18
A.22
PEEC4ATEK0150
PEEC4ATEK0250
A.23
A.25
PEEE3ATEM0250
PEEE3ATGR0125
A.25
A.10
PEEH2ATSB0150
PEEH2ATSB0250
A.22
A.24
PEEH4ATSE0150
PEEH4ATSE0250
A.23
A.25
PEEL3ATSH0250
PEEL3ATTS0125
A.25
A.10
PEEC2ATAM0250 A.24 PEEC4ATEL0125 A.19 PEEE3ATGR0150 A.10 PEEH2ATSE0125 A.18 PEEH4ATSF0125 A.19 PEEL3ATTS0150 A.10
PEEC2ATEJ0125 A.18 PEEC4ATEL0150 A.23 PEEE3ATGR0200 A.10 PEEH2ATSE0150 A.22 PEEH4ATSF0150 A.23 PEEL3ATTS0200 A.10
PEEC2ATEJ0150 A.22 PEEC4ATEL0250 A.25 PEEE3ATGR0225 A.10 PEEH2ATSE0250 A.24 PEEH4ATSF0250 A.25 PEEL3ATTS0225 A.10
PEEC2ATEK0125 A.18 PEEC4ATEM0125 A.19 PEEE3ATGR0250 A.10 PEEH2ATSF0125 A.18 PEEH4ATSH0125 A.19 PEEL3ATTS0250 A.10
E PEEC2ATEK0150
PEEC2ATEL0125
A.22
A.18
PEEC4ATEM0150
PEEC4ATEM0250
A.23
A.25
PEEE3ATSB0125
PEEE3ATSB0150
A.19
A.23
PEEH2ATSF0150
PEEH2ATSF0250
A.22
A.24
PEEH4ATSH0150
PEEH4ATSH0250
A.23
A.25
PEEL4ATAJ0125
PEEL4ATAJ0150
A.19
A.23
PEEC2ATEL0150 A.22 PEEC4ATGR0125 A.11 PEEE3ATSB0250 A.25 PEEH2ATSH0125 A.18 PEEH4ATTR0125 A.11 PEEL4ATAJ0250 A.25
PEEC2ATEM0125 A.18 PEEC4ATGR0150 A.11 PEEE3ATSE0125 A.19 PEEH2ATSH0150 A.22 PEEH4ATTR0150 A.11 PEEL4ATAK0125 A.19
PEEC2ATEM0150 A.22 PEEC4ATGR0200 A.11 PEEE3ATSE0150 A.23 PEEH2ATSH0250 A.24 PEEH4ATTR0200 A.11 PEEL4ATAK0150 A.23
F PEEC2ATGS0125
PEEC2ATGS0150
A.9
A.9
PEEC4ATGR0225
PEEC4ATGR0250
A.11
A.11
PEEE3ATSE0250
PEEE3ATSF0125
A.25
A.19
PEEH2ATTR0125
PEEH2ATTR0150
A.9
A.9
PEEH4ATTR0225
PEEH4ATTR0250
A.11
A.11
PEEL4ATAK0250
PEEL4ATAL0125
A.25
A.19
PEEC2ATGS0200 A.9 PEEC4ATSB0125 A.19 PEEE3ATSF0150 A.23 PEEH2ATTR0200 A.9 PEEL2ATAJ0125 A.18 PEEL4ATAL0150 A.23
PEEC2ATGS0225 A.9 PEEC4ATSB0150 A.23 PEEE3ATSF0250 A.25 PEEH2ATTR0225 A.9 PEEL2ATAJ0150 A.22 PEEL4ATAL0250 A.25
PEEC2ATGS0250 A.9 PEEC4ATSB0250 A.25 PEEE3ATSH0125 A.19 PEEH2ATTR0250 A.9 PEEL2ATAJ0250 A.24 PEEL4ATAM0125 A.19
PEEC2ATSB0125 PEEC4ATSE0125 PEEE3ATSH0150 PEEH3ATAJ0125 PEEL2ATAK0125 PEEL4ATAM0150
G PEEC2ATSB0150
A.18
A.22 PEEC4ATSE0150
A.19
A.23 PEEE3ATSH0250
A.23
A.25 PEEH3ATAJ0150
A.19
A.23 PEEL2ATAK0150
A.18
A.22 PEEL4ATAM0250
A.23
A.25
PEEC2ATSB0250 A.24 PEEC4ATSE0250 A.25 PEEE3ATTS0125 A.10 PEEH3ATAJ0250 A.25 PEEL2ATAK0250 A.24 PEEL4ATEJ0125 A.19
PEEC2ATSE0125 A.18 PEEC4ATSF0125 A.19 PEEE3ATTS0150 A.10 PEEH3ATAK0125 A.19 PEEL2ATAL0125 A.18 PEEL4ATEJ0150 A.23
PEEC2ATSE0150 A.22 PEEC4ATSF0150 A.23 PEEE3ATTS0200 A.10 PEEH3ATAK0150 A.23 PEEL2ATAL0150 A.22 PEEL4ATEJ0250 A.25
PEEC2ATSE0250 A.24 PEEC4ATSF0250 A.25 PEEE3ATTS0225 A.10 PEEH3ATAK0250 A.25 PEEL2ATAL0250 A.24 PEEL4ATEK0125 A.19
X PEEC2ATSF0125
PEEC2ATSF0150
A.18
A.22
PEEC4ATSH0125
PEEC4ATSH0150
A.19
A.23
PEEE3ATTS0250
PEEE4ATAJ0125
A.10
A.19
PEEH3ATAL0125
PEEH3ATAL0150
A.19
A.23
PEEL2ATAM0125
PEEL2ATAM0150
A.18
A.22
PEEL4ATEK0150
PEEL4ATEK0250
A.23
A.25
PEEC2ATSF0250 A.24 PEEC4ATSH0250 A.25 PEEE4ATAJ0150 A.23 PEEH3ATAL0250 A.25 PEEL2ATAM0250 A.24 PEEL4ATEL0125 A.19
PEEC2ATSH0125 A.18 PEEC4ATTR0125 A.11 PEEE4ATAJ0250 A.25 PEEH3ATAM0125 A.19 PEEL2ATEJ0125 A.18 PEEL4ATEL0150 A.23
PEEC2ATSH0150 A.22 PEEC4ATTR0150 A.11 PEEE4ATAK0125 A.19 PEEH3ATAM0150 A.23 PEEL2ATEJ0150 A.22 PEEL4ATEL0250 A.25
PEEC2ATSH0250 A.24 PEEC4ATTR0200 A.11 PEEE4ATAK0150 A.23 PEEH3ATAM0250 A.25 PEEL2ATEK0125 A.18 PEEL4ATEM0125 A.19
PEEC2ATTR0125 A.9 PEEC4ATTR0225 A.11 PEEE4ATAK0250 A.25 PEEH3ATEJ0125 A.19 PEEL2ATEK0150 A.22 PEEL4ATEM0150 A.23
PEEC2ATTR0150 A.9 PEEC4ATTR0250 A.11 PEEE4ATAL0125 A.19 PEEH3ATEJ0150 A.23 PEEL2ATEL0125 A.18 PEEL4ATEM0250 A.25
PEEC2ATTR0200 A.9 PEEE2ATAJ0125 A.18 PEEE4ATAL0150 A.23 PEEH3ATEJ0250 A.25 PEEL2ATEL0150 A.22 PEEL4ATGR0125 A.11
PEEC2ATTR0225 A.9 PEEE2ATAJ0150 A.22 PEEE4ATAL0250 A.25 PEEH3ATEK0125 A.19 PEEL2ATEM0125 A.18 PEEL4ATGR0150 A.11
PEEC2ATTR0250 A.9 PEEE2ATAJ0250 A.24 PEEE4ATAM0125 A.19 PEEH3ATEK0150 A.23 PEEL2ATEM0150 A.22 PEEL4ATGR0200 A.11
PEEC3ATAJ0125 A.19 PEEE2ATAK0125 A.18 PEEE4ATAM0150 A.23 PEEH3ATEK0250 A.25 PEEL2ATGS0125 A.9 PEEL4ATGR0225 A.11
PEEC3ATAJ0150 A.23 PEEE2ATAK0150 A.22 PEEE4ATAM0250 A.25 PEEH3ATEL0125 A.19 PEEL2ATGS0150 A.9 PEEL4ATGR0250 A.11
PEEC3ATAJ0250 A.25 PEEE2ATAK0250 A.24 PEEE4ATEJ0125 A.19 PEEH3ATEL0150 A.23 PEEL2ATGS0200 A.9 PEEL4ATSB0125 A.19
PEEC3ATAK0125 A.19 PEEE2ATAL0125 A.18 PEEE4ATEJ0150 A.23 PEEH3ATEL0250 A.25 PEEL2ATGS0225 A.9 PEEL4ATSB0150 A.23
PEEC3ATAK0150 A.23 PEEE2ATAL0150 A.22 PEEE4ATEJ0250 A.25 PEEH3ATEM0125 A.19 PEEL2ATGS0250 A.9 PEEL4ATSB0250 A.25

X.8
GuardEon
Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page
PEEL4ATSE0125 A.19 PEEN3ATSH0150 A.23 PGAC3ATEK0600 A.34 PGAL2ATEJ0600 A.34 PGAP4ATAM0600 A.34 PGFE2ATEM0250 A.28
PEEL4ATSE0150 A.23 PEEN3ATSH0250 A.25 PGAC3ATEL0600 A.34 PGAL2ATEK0600 A.34 PGAP4ATEJ0600 A.34 PGFE2ATEM0400 A.31
PEEL4ATSE0250 A.25 PEEN3ATTS0125 A.10 PGAC3ATEM0600 A.34 PGAL2ATEL0600 A.34 PGAP4ATEK0600 A.34 PGFE2ATSB0250 A.28
PEEL4ATSF0125 A.19 PEEN3ATTS0150 A.10 PGAC3ATSB0600 A.34 PGAL2ATEM0600 A.34 PGAP4ATEL0600 A.34 PGFE2ATSB0400 A.31
PEEL4ATSF0150 A.23 PEEN3ATTS0200 A.10 PGAC3ATSE0600 A.34 PGAL2ATSB0600 A.34 PGAP4ATEM0600 A.34 PGFE2ATSE0250 A.28
PEEL4ATSF0250 A.25 PEEN3ATTS0225 A.10 PGAC3ATSF0600 A.34 PGAL2ATSE0600 A.34 PGAP4ATSB0600 A.34 PGFE2ATSE0400 A.31
PEEL4ATSH0125 A.19 PEEN3ATTS0250 A.10 PGAC3ATSH0600 A.34 PGAL2ATSF0600 A.34 PGAP4ATSE0600 A.34 PGFE2ATSF0250 A.28
PEEL4ATSH0150 A.23 PEEN4ATAJ0125 A.19 PGAC4ATAJ0600 A.34 PGAL2ATSH0600 A.34 PGAP4ATSF0600 A.34 PGFE2ATSF0400 A.31
PEEL4ATSH0250 A.25 PEEN4ATAJ0150 A.23 PGAC4ATAK0600 A.34 PGAL3ATAJ0600 A.34 PGAP4ATSH0600 A.34 PGFE2ATSH0250 A.28
PEEL4ATTR0125 A.11 PEEN4ATAJ0250 A.25 PGAC4ATAL0600 A.34 PGAL3ATAK0600 A.34 PGFC2ATAJ0250 A.28 PGFE2ATSH0400 A.31
PEEL4ATTR0150 A.11 PEEN4ATAK0125 A.19 PGAC4ATAM0600 A.34 PGAL3ATAL0600 A.34 PGFC2ATAJ0400 A.31 PGFE3ATAJ0250 A.29
PEEL4ATTR0200 A.11 PEEN4ATAK0150 A.23 PGAC4ATEJ0600 A.34 PGAL3ATAM0600 A.34 PGFC2ATAK0250 A.28 PGFE3ATAJ0400 A.32
PEEL4ATTR0225 A.11 PEEN4ATAK0250 A.25 PGAC4ATEK0600 A.34 PGAL3ATEJ0600 A.34 PGFC2ATAK0400 A.31 PGFE3ATAK0250 A.29
PEEL4ATTR0250 A.11 PEEN4ATAL0125 A.19 PGAC4ATEL0600 A.34 PGAL3ATEK0600 A.34 PGFC2ATAL0250 A.28 PGFE3ATAK0400 A.32

By catalogue number
PEEN2ATAJ0125 A.18 PEEN4ATAL0150 A.23 PGAC4ATEM0600 A.34 PGAL3ATEL0600 A.34 PGFC2ATAL0400 A.31 PGFE3ATAL0250 A.29
PEEN2ATAJ0150 A.22 PEEN4ATAL0250 A.25 PGAC4ATSB0600 A.34 PGAL3ATEM0600 A.34 PGFC2ATAM0250 A.28 PGFE3ATAL0400 A.32
PEEN2ATAJ0250 A.24 PEEN4ATAM0125 A.19 PGAC4ATSE0600 A.34 PGAL3ATSB0600 A.34 PGFC2ATAM0400 A.31 PGFE3ATAM0250 A.29
PEEN2ATAK0125 A.18 PEEN4ATAM0150 A.23 PGAC4ATSF0600 A.34 PGAL3ATSE0600 A.34 PGFC2ATEJ0250 A.28 PGFE3ATAM0400 A.32
PEEN2ATAK0150 A.22 PEEN4ATAM0250 A.25 PGAC4ATSH0600 A.34 PGAL3ATSF0600 A.34 PGFC2ATEJ0400 A.31 PGFE3ATEJ0250 A.29
PEEN2ATAK0250 A.24 PEEN4ATEJ0125 A.19 PGAE2ATAJ0600 A.34 PGAL3ATSH0600 A.34 PGFC2ATEK0250 A.28 PGFE3ATEJ0400 A.32
PEEN2ATAL0125 A.18 PEEN4ATEJ0150 A.23 PGAE2ATAK0600 A.34 PGAL4ATAJ0600 A.34 PGFC2ATEK0400 A.31 PGFE3ATEK0250 A.29
PEEN2ATAL0150 A.22 PEEN4ATEJ0250 A.25 PGAE2ATAL0600 A.34 PGAL4ATAK0600 A.34 PGFC2ATEL0250 A.28 PGFE3ATEK0400 A.32
PEEN2ATAL0250 A.24 PEEN4ATEK0125 A.19 PGAE2ATAM0600 A.34 PGAL4ATAL0600 A.34 PGFC2ATEL0400 A.31 PGFE3ATEL0250 A.29
PEEN2ATAM0125 A.18 PEEN4ATEK0150 A.23 PGAE2ATEJ0600 A.34 PGAL4ATAM0600 A.34 PGFC2ATEM0250 A.28 PGFE3ATEL0400 A.32
PEEN2ATAM0150 A.22 PEEN4ATEK0250 A.25 PGAE2ATEK0600 A.34 PGAL4ATEJ0600 A.34 PGFC2ATEM0400 A.31 PGFE3ATEM0250 A.29
PEEN2ATAM0250 A.24 PEEN4ATEL0125 A.19 PGAE2ATEL0600 A.34 PGAL4ATEK0600 A.34 PGFC2ATSB0250 A.28 PGFE3ATEM0400 A.32
PEEN2ATEJ0125 A.18 PEEN4ATEL0150 A.23 PGAE2ATEM0600 A.34 PGAL4ATEL0600 A.34 PGFC2ATSB0400 A.31 PGFE3ATSB0250 A.29
PEEN2ATEJ0150 A.22 PEEN4ATEL0250 A.25 PGAE2ATSB0600 A.34 PGAL4ATEM0600 A.34 PGFC2ATSE0250 A.28 PGFE3ATSB0400 A.32
PEEN2ATEK0125 A.18 PEEN4ATEM0125 A.19 PGAE2ATSE0600 A.34 PGAL4ATSB0600 A.34 PGFC2ATSE0400 A.31 PGFE3ATSE0250 A.29
PEEN2ATEK0150 A.22 PEEN4ATEM0150 A.23 PGAE2ATSF0600 A.34 PGAL4ATSE0600 A.34 PGFC2ATSF0250 A.28 PGFE3ATSE0400 A.32
PEEN2ATEL0125 A.18 PEEN4ATEM0250 A.25 PGAE2ATSH0600 A.34 PGAL4ATSF0600 A.34 PGFC2ATSF0400 A.31 PGFE3ATSF0250 A.29
PEEN2ATEL0150 A.22 PEEN4ATGR0125 A.11 PGAE3ATAJ0600 A.34 PGAL4ATSH0600 A.34 PGFC2ATSH0250 A.28 PGFE3ATSF0400 A.32
PEEN2ATEM0125 A.18 PEEN4ATGR0150 A.11 PGAE3ATAK0600 A.34 PGAN2ATAJ0600 A.34 PGFC2ATSH0400 A.31 PGFE3ATSH0250 A.29
PEEN2ATEM0150 A.22 PEEN4ATGR0200 A.11 PGAE3ATAL0600 A.34 PGAN2ATAK0600 A.34 PGFC3ATAJ0250 A.29 PGFE3ATSH0400 A.32
PEEN2ATGS0125 A.9 PEEN4ATGR0225 A.11 PGAE3ATAM0600 A.34 PGAN2ATAL0600 A.34 PGFC3ATAJ0400 A.32 PGFE4ATAJ0250 A.30
PEEN2ATGS0150 A.9 PEEN4ATGR0250 A.11 PGAE3ATEJ0600 A.34 PGAN2ATAM0600 A.34 PGFC3ATAK0250 A.29 PGFE4ATAJ0400 A.33
PEEN2ATGS0200
PEEN2ATGS0225
A.9
A.9
PEEN4ATSB0125
PEEN4ATSB0150
A.19
A.23
PGAE3ATEK0600
PGAE3ATEL0600
A.34
A.34
PGAN2ATEJ0600
PGAN2ATEK0600
A.34
A.34
PGFC3ATAK0400
PGFC3ATAL0250
A.32
A.29
PGFE4ATAK0250
PGFE4ATAK0400
A.30
A.33
Intro
PEEN2ATGS0250 A.9 PEEN4ATSB0250 A.25 PGAE3ATEM0600 A.34 PGAN2ATEL0600 A.34 PGFC3ATAL0400 A.32 PGFE4ATAL0250 A.30
PEEN2ATSB0125 A.18 PEEN4ATSE0125 A.19 PGAE3ATSB0600 A.34 PGAN2ATEM0600 A.34 PGFC3ATAM0250 A.29 PGFE4ATAL0400 A.33
PEEN2ATSB0150 A.22 PEEN4ATSE0150 A.23 PGAE3ATSE0600 A.34 PGAN2ATSB0600 A.34 PGFC3ATAM0400 A.32 PGFE4ATAM0250 A.30
PEEN2ATSB0250
PEEN2ATSE0125
A.24
A.18
PEEN4ATSE0250
PEEN4ATSF0125
A.25
A.19
PGAE3ATSF0600
PGAE3ATSH0600
A.34
A.34
PGAN2ATSE0600
PGAN2ATSF0600
A.34
A.34
PGFC3ATEJ0250
PGFC3ATEJ0400
A.29
A.32
PGFE4ATAM0400
PGFE4ATEJ0250
A.33
A.30 A
PEEN2ATSE0150 A.22 PEEN4ATSF0150 A.23 PGAE4ATAJ0600 A.34 PGAN2ATSH0600 A.34 PGFC3ATEK0250 A.29 PGFE4ATEJ0400 A.33
PEEN2ATSE0250 A.24 PEEN4ATSF0250 A.25 PGAE4ATAK0600 A.34 PGAN3ATAJ0600 A.34 PGFC3ATEK0400 A.32 PGFE4ATEK0250 A.30
PEEN2ATSF0125 A.18 PEEN4ATSH0125 A.19 PGAE4ATAL0600 A.34 PGAN3ATAK0600 A.34 PGFC3ATEL0250 A.29 PGFE4ATEK0400 A.33
PEEN2ATSF0150 A.22 PEEN4ATSH0150 A.23 PGAE4ATAM0600 A.34 PGAN3ATAL0600 A.34 PGFC3ATEL0400 A.32 PGFE4ATEL0250 A.30
PEEN2ATSF0250
PEEN2ATSH0125
A.24
A.18
PEEN4ATSH0250
PEEN4ATTR0125
A.25
A.11
PGAE4ATEJ0600
PGAE4ATEK0600
A.34
A.34
PGAN3ATAM0600
PGAN3ATEJ0600
A.34
A.34
PGFC3ATEM0250
PGFC3ATEM0400
A.29
A.32
PGFE4ATEL0400
PGFE4ATEM0250
A.33
A.30
B
PEEN2ATSH0150 A.22 PEEN4ATTR0150 A.11 PGAE4ATEL0600 A.34 PGAN3ATEK0600 A.34 PGFC3ATSB0250 A.29 PGFE4ATEM0400 A.33
PEEN2ATSH0250 A.24 PEEN4ATTR0200 A.11 PGAE4ATEM0600 A.34 PGAN3ATEL0600 A.34 PGFC3ATSB0400 A.32 PGFE4ATSB0250 A.30
PEEN2ATTR0125 A.9 PEEN4ATTR0225 A.11 PGAE4ATSB0600 A.34 PGAN3ATEM0600 A.34 PGFC3ATSE0250 A.29 PGFE4ATSB0400 A.33
PEEN2ATTR0150
PEEN2ATTR0200
A.9
A.9
PEEN4ATTR0250
PEJB
A.11
C.10
PGAE4ATSE0600
PGAE4ATSF0600
A.34
A.34
PGAN3ATSB0600
PGAN3ATSE0600
A.34
A.34
PGFC3ATSE0400
PGFC3ATSF0250
A.32
A.29
PGFE4ATSE0250
PGFE4ATSE0400
A.30
A.33
C
PEEN2ATTR0225 A.9 PEJL3 C.10 PGAE4ATSH0600 A.34 PGAN3ATSF0600 A.34 PGFC3ATSF0400 A.32 PGFE4ATSF0250 A.30
PEEN2ATTR0250 A.9 PEJL4 C.10 PGAH2ATAJ0600 A.34 PGAN3ATSH0600 A.34 PGFC3ATSH0250 A.29 PGFE4ATSF0400 A.33
PEEN3ATAJ0125 A.19 PEJS3 C.10 PGAH2ATAK0600 A.34 PGAN4ATAJ0600 A.34 PGFC3ATSH0400 A.32 PGFE4ATSH0250 A.30
PEEN3ATAJ0150
PEEN3ATAJ0250
A.23
A.25
PEJS4
PEKD3
C.10
C.6
PGAH2ATAL0600
PGAH2ATAM0600
A.34
A.34
PGAN4ATAK0600
PGAN4ATAL0600
A.34
A.34
PGFC4ATAJ0250
PGFC4ATAJ0400
A.30
A.33
PGFE4ATSH0400
PGFH2ATAJ0250
A.33
A.28 D
PEEN3ATAK0125 A.19 PEKD4 C.6 PGAH2ATEJ0600 A.34 PGAN4ATAM0600 A.34 PGFC4ATAK0250 A.30 PGFH2ATAJ0400 A.31
PEEN3ATAK0150 A.23 PENBM C.6 PGAH2ATEK0600 A.34 PGAN4ATEJ0600 A.34 PGFC4ATAK0400 A.33 PGFH2ATAK0250 A.28
PEEN3ATAK0250 A.25 PENR4 C.5 PGAH2ATEL0600 A.34 PGAN4ATEK0600 A.34 PGFC4ATAL0250 A.30 PGFH2ATAK0400 A.31
PEEN3ATAL0125 A.19 PENRE C.5 PGAH2ATEM0600 A.34 PGAN4ATEL0600 A.34 PGFC4ATAL0400 A.33 PGFH2ATAL0250 A.28
PEEN3ATAL0150
PEEN3ATAL0250
A.23
A.25
PENRW
PEQDB3HJ
C.5
C.6
PGAH2ATSB0600
PGAH2ATSE0600
A.34
A.34
PGAN4ATEM0600
PGAN4ATSB0600
A.34
A.34
PGFC4ATAM0250
PGFC4ATAM0400
A.30
A.33
PGFH2ATAL0400
PGFH2ATAM0250
A.31
A.28
E
PEEN3ATAM0125 A.19 PEQDB3HK C.6 PGAH2ATSF0600 A.34 PGAN4ATSE0600 A.34 PGFC4ATEJ0250 A.30 PGFH2ATAM0400 A.31
PEEN3ATAM0150 A.23 PEQDB3MJ C.6 PGAH2ATSH0600 A.34 PGAN4ATSF0600 A.34 PGFC4ATEJ0400 A.33 PGFH2ATEJ0250 A.28
PEEN3ATAM0250 A.25 PEQDB3MK C.6 PGAH3ATAJ0600 A.34 PGAN4ATSH0600 A.34 PGFC4ATEK0250 A.30 PGFH2ATEJ0400 A.31
PEEN3ATEJ0125
PEEN3ATEJ0150
A.19
A.23
PEQDB4HJ
PEQDB4HK
C.6
C.6
PGAH3ATAK0600
PGAH3ATAL0600
A.34
A.34
PGAP2ATAJ0600
PGAP2ATAK0600
A.34
A.34
PGFC4ATEK0400
PGFC4ATEL0250
A.33
A.30
PGFH2ATEK0250
PGFH2ATEK0400
A.28
A.31 F
PEEN3ATEJ0250 A.25 PEQDB4MJ C.6 PGAH3ATAM0600 A.34 PGAP2ATAL0600 A.34 PGFC4ATEL0400 A.33 PGFH2ATEL0250 A.28
PEEN3ATEK0125 A.19 PEQDB4MK C.6 PGAH3ATEJ0600 A.34 PGAP2ATAM0600 A.34 PGFC4ATEM0250 A.30 PGFH2ATEL0400 A.31
PEEN3ATEK0150 A.23 PEWB3 C.8 PGAH3ATEK0600 A.34 PGAP2ATEJ0600 A.34 PGFC4ATEM0400 A.33 PGFH2ATEM0250 A.28
PEEN3ATEK0250 PEWB4 PGAH3ATEL0600 PGAP2ATEK0600 PGFC4ATSB0250 PGFH2ATEM0400
PEEN3ATEL0125
A.25
A.19 PEWM
C.8
C.8 PGAH3ATEM0600
A.34
A.34 PGAP2ATEL0600
A.34
A.34 PGFC4ATSB0400
A.30
A.33 PGFH2ATSB0250
A.31
A.28 G
PEEN3ATEL0150 A.23 PEWN C.8 PGAH3ATSB0600 A.34 PGAP2ATEM0600 A.34 PGFC4ATSE0250 A.30 PGFH2ATSB0400 A.31
PEEN3ATEL0250 A.25 PEWT C.8 PGAH3ATSE0600 A.34 PGAP2ATSB0600 A.34 PGFC4ATSE0400 A.33 PGFH2ATSE0250 A.28
PEEN3ATEM0125 A.19 PG… PGAH3ATSF0600 A.34 PGAP2ATSE0600 A.34 PGFC4ATSF0250 A.30 PGFH2ATSE0400 A.31
PEEN3ATEM0150 A.23 PGAC2ATAJ0600 A.34 PGAH3ATSH0600 A.34 PGAP2ATSF0600 A.34 PGFC4ATSF0400 A.33 PGFH2ATSF0250 A.28
PEEN3ATEM0250
PEEN3ATGR0125
A.25
A.10
PGAC2ATAK0600
PGAC2ATAL0600
A.34
A.34
PGAH4ATAJ0600
PGAH4ATAK0600
A.34
A.34
PGAP2ATSH0600
PGAP3ATAJ0600
A.34
A.34
PGFC4ATSH0250
PGFC4ATSH0400
A.30
A.33
PGFH2ATSF0400
PGFH2ATSH0250
A.31
A.28
X
PEEN3ATGR0150 A.10 PGAC2ATAM0600 A.34 PGAH4ATAL0600 A.34 PGAP3ATAK0600 A.34 PGFE2ATAJ0250 A.28 PGFH2ATSH0400 A.31
PEEN3ATGR0200 A.10 PGAC2ATEJ0600 A.34 PGAH4ATAM0600 A.34 PGAP3ATAL0600 A.34 PGFE2ATAJ0400 A.31 PGFH3ATAJ0250 A.29
PEEN3ATGR0225 A.10 PGAC2ATEK0600 A.34 PGAH4ATEJ0600 A.34 PGAP3ATAM0600 A.34 PGFE2ATAK0250 A.28 PGFH3ATAJ0400 A.32
PEEN3ATGR0250 A.10 PGAC2ATEL0600 A.34 PGAH4ATEK0600 A.34 PGAP3ATEJ0600 A.34 PGFE2ATAK0400 A.31 PGFH3ATAK0250 A.29
PEEN3ATSB0125 A.19 PGAC2ATEM0600 A.34 PGAH4ATEL0600 A.34 PGAP3ATEK0600 A.34 PGFE2ATAL0250 A.28 PGFH3ATAK0400 A.32
PEEN3ATSB0150 A.23 PGAC2ATSB0600 A.34 PGAH4ATEM0600 A.34 PGAP3ATEL0600 A.34 PGFE2ATAL0400 A.31 PGFH3ATAL0250 A.29
PEEN3ATSB0250 A.25 PGAC2ATSE0600 A.34 PGAH4ATSB0600 A.34 PGAP3ATEM0600 A.34 PGFE2ATAM0250 A.28 PGFH3ATAL0400 A.32
PEEN3ATSE0125 A.19 PGAC2ATSF0600 A.34 PGAH4ATSE0600 A.34 PGAP3ATSB0600 A.34 PGFE2ATAM0400 A.31 PGFH3ATAM0250 A.29
PEEN3ATSE0150 A.23 PGAC2ATSH0600 A.34 PGAH4ATSF0600 A.34 PGAP3ATSE0600 A.34 PGFE2ATEJ0250 A.28 PGFH3ATAM0400 A.32
PEEN3ATSE0250 A.25 PGAC3ATAJ0600 A.34 PGAH4ATSH0600 A.34 PGAP3ATSF0600 A.34 PGFE2ATEJ0400 A.31 PGFH3ATEJ0250 A.29
PEEN3ATSF0125 A.19 PGAC3ATAK0600 A.34 PGAL2ATAJ0600 A.34 PGAP3ATSH0600 A.34 PGFE2ATEK0250 A.28 PGFH3ATEJ0400 A.32
PEEN3ATSF0150 A.23 PGAC3ATAL0600 A.34 PGAL2ATAK0600 A.34 PGAP4ATAJ0600 A.34 PGFE2ATEK0400 A.31 PGFH3ATEK0250 A.29
PEEN3ATSF0250 A.25 PGAC3ATAM0600 A.34 PGAL2ATAL0600 A.34 PGAP4ATAK0600 A.34 PGFE2ATEL0250 A.28 PGFH3ATEK0400 A.32
PEEN3ATSH0125 A.19 PGAC3ATEJ0600 A.34 PGAL2ATAM0600 A.34 PGAP4ATAL0600 A.34 PGFE2ATEL0400 A.31 PGFH3ATEL0250 A.29

X.9
GuardEon
Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page
PGFH3ATEL0400 A.32 PGFL4ATEL0250 A.30 PGFP2ATEK0400 A.31 PGGC4ATAJ0400 A.33 PGGH4ATAJ0250 A.30 PGGN3ATEM0400 A.32
PGFH3ATEM0250 A.29 PGFL4ATEL0400 A.33 PGFP2ATEL0250 A.28 PGGC4ATAK0250 A.30 PGGH4ATAJ0400 A.33 PGGN4ATAJ0250 A.30
PGFH3ATEM0400 A.32 PGFL4ATEM0250 A.30 PGFP2ATEL0400 A.31 PGGC4ATAK0400 A.33 PGGH4ATAK0250 A.30 PGGN4ATAJ0400 A.33
PGFH3ATSB0250 A.29 PGFL4ATEM0400 A.33 PGFP2ATEM0250 A.28 PGGC4ATAL0250 A.30 PGGH4ATAK0400 A.33 PGGN4ATAK0250 A.30
PGFH3ATSB0400 A.32 PGFL4ATSB0250 A.30 PGFP2ATEM0400 A.31 PGGC4ATAL0400 A.33 PGGH4ATAL0250 A.30 PGGN4ATAK0400 A.33
PGFH3ATSE0250 A.29 PGFL4ATSB0400 A.33 PGFP2ATSB0250 A.28 PGGC4ATAM0250 A.30 PGGH4ATAL0400 A.33 PGGN4ATAL0250 A.30
PGFH3ATSE0400 A.32 PGFL4ATSE0250 A.30 PGFP2ATSB0400 A.31 PGGC4ATAM0400 A.33 PGGH4ATAM0250 A.30 PGGN4ATAL0400 A.33
PGFH3ATSF0250 A.29 PGFL4ATSE0400 A.33 PGFP2ATSE0250 A.28 PGGC4ATEJ0250 A.30 PGGH4ATAM0400 A.33 PGGN4ATAM0250 A.30
PGFH3ATSF0400 A.32 PGFL4ATSF0250 A.30 PGFP2ATSE0400 A.31 PGGC4ATEJ0400 A.33 PGGH4ATEJ0250 A.30 PGGN4ATAM0400 A.33
PGFH3ATSH0250 A.29 PGFL4ATSF0400 A.33 PGFP2ATSF0250 A.28 PGGC4ATEK0250 A.30 PGGH4ATEJ0400 A.33 PGGN4ATEJ0250 A.30
PGFH3ATSH0400 A.32 PGFL4ATSH0250 A.30 PGFP2ATSF0400 A.31 PGGC4ATEK0400 A.33 PGGH4ATEK0250 A.30 PGGN4ATEJ0400 A.33
PGFH4ATAJ0250 A.30 PGFL4ATSH0400 A.33 PGFP2ATSH0250 A.28 PGGC4ATEL0250 A.30 PGGH4ATEK0400 A.33 PGGN4ATEK0250 A.30
PGFH4ATAJ0400 A.33 PGFN2ATAJ0250 A.28 PGFP2ATSH0400 A.31 PGGC4ATEL0400 A.33 PGGH4ATEL0250 A.30 PGGN4ATEK0400 A.33
PGFH4ATAK0250 A.30 PGFN2ATAJ0400 A.31 PGFP3ATAJ0250 A.29 PGGC4ATEM0250 A.30 PGGH4ATEL0400 A.33 PGGN4ATEL0250 A.30
PGFH4ATAK0400 A.33 PGFN2ATAK0250 A.28 PGFP3ATAJ0400 A.32 PGGC4ATEM0400 A.33 PGGH4ATEM0250 A.30 PGGN4ATEL0400 A.33
PGFH4ATAL0250 A.30 PGFN2ATAK0400 A.31 PGFP3ATAK0250 A.29 PGGE2ATAJ0250 A.28 PGGH4ATEM0400 A.33 PGGN4ATEM0250 A.30
PGFH4ATAL0400 A.33 PGFN2ATAL0250 A.28 PGFP3ATAK0400 A.32 PGGE2ATAJ0400 A.31 PGGL2ATAJ0250 A.28 PGGN4ATEM0400 A.33
PGFH4ATAM0250 A.30 PGFN2ATAL0400 A.31 PGFP3ATAL0250 A.29 PGGE2ATAK0250 A.28 PGGL2ATAJ0400 A.31 PGGP2ATAJ0250 A.28
Numerical index

PGFH4ATAM0400 A.33 PGFN2ATAM0250 A.28 PGFP3ATAL0400 A.32 PGGE2ATAK0400 A.31 PGGL2ATAK0250 A.28 PGGP2ATAJ0400 A.31
PGFH4ATEJ0250 A.30 PGFN2ATAM0400 A.31 PGFP3ATAM0250 A.29 PGGE2ATAL0250 A.28 PGGL2ATAK0400 A.31 PGGP2ATAK0250 A.28
PGFH4ATEJ0400 A.33 PGFN2ATEJ0250 A.28 PGFP3ATAM0400 A.32 PGGE2ATAL0400 A.31 PGGL2ATAL0250 A.28 PGGP2ATAK0400 A.31
PGFH4ATEK0250 A.30 PGFN2ATEJ0400 A.31 PGFP3ATEJ0250 A.29 PGGE2ATAM0250 A.28 PGGL2ATAL0400 A.31 PGGP2ATAL0250 A.28
PGFH4ATEK0400 A.33 PGFN2ATEK0250 A.28 PGFP3ATEJ0400 A.32 PGGE2ATAM0400 A.31 PGGL2ATAM0250 A.28 PGGP2ATAL0400 A.31
PGFH4ATEL0250 A.30 PGFN2ATEK0400 A.31 PGFP3ATEK0250 A.29 PGGE2ATEJ0250 A.28 PGGL2ATAM0400 A.31 PGGP2ATAM0250 A.28
PGFH4ATEL0400 A.33 PGFN2ATEL0250 A.28 PGFP3ATEK0400 A.32 PGGE2ATEJ0400 A.31 PGGL2ATEJ0250 A.28 PGGP2ATAM0400 A.31
PGFH4ATEM0250 A.30 PGFN2ATEL0400 A.31 PGFP3ATEL0250 A.29 PGGE2ATEK0250 A.28 PGGL2ATEJ0400 A.31 PGGP2ATEJ0250 A.28
PGFH4ATEM0400 A.33 PGFN2ATEM0250 A.28 PGFP3ATEL0400 A.32 PGGE2ATEK0400 A.31 PGGL2ATEK0250 A.28 PGGP2ATEJ0400 A.31
PGFH4ATSB0250 A.30 PGFN2ATEM0400 A.31 PGFP3ATEM0250 A.29 PGGE2ATEL0250 A.28 PGGL2ATEK0400 A.31 PGGP2ATEK0250 A.28
PGFH4ATSB0400 A.33 PGFN2ATSB0250 A.28 PGFP3ATEM0400 A.32 PGGE2ATEL0400 A.31 PGGL2ATEL0250 A.28 PGGP2ATEK0400 A.31
PGFH4ATSE0250 A.30 PGFN2ATSB0400 A.31 PGFP3ATSB0250 A.29 PGGE2ATEM0250 A.28 PGGL2ATEL0400 A.31 PGGP2ATEL0250 A.28
PGFH4ATSE0400 A.33 PGFN2ATSE0250 A.28 PGFP3ATSB0400 A.32 PGGE2ATEM0400 A.31 PGGL2ATEM0250 A.28 PGGP2ATEL0400 A.31
PGFH4ATSF0250 A.30 PGFN2ATSE0400 A.31 PGFP3ATSE0250 A.29 PGGE3ATAJ0250 A.29 PGGL2ATEM0400 A.31 PGGP2ATEM0250 A.28
PGFH4ATSF0400 A.33 PGFN2ATSF0250 A.28 PGFP3ATSE0400 A.32 PGGE3ATAJ0400 A.32 PGGL3ATAJ0250 A.29 PGGP2ATEM0400 A.31
PGFH4ATSH0250 A.30 PGFN2ATSF0400 A.31 PGFP3ATSF0250 A.29 PGGE3ATAK0250 A.29 PGGL3ATAJ0400 A.32 PGGP3ATAJ0250 A.29
PGFH4ATSH0400 A.33 PGFN2ATSH0250 A.28 PGFP3ATSF0400 A.32 PGGE3ATAK0400 A.32 PGGL3ATAK0250 A.29 PGGP3ATAJ0400 A.32
PGFL2ATAJ0250 A.28 PGFN2ATSH0400 A.31 PGFP3ATSH0250 A.29 PGGE3ATAL0250 A.29 PGGL3ATAK0400 A.32 PGGP3ATAK0250 A.29
Intro PGFL2ATAJ0400
PGFL2ATAK0250
A.31
A.28
PGFN3ATAJ0250
PGFN3ATAJ0400
A.29
A.32
PGFP3ATSH0400
PGFP4ATAJ0250
A.32
A.30
PGGE3ATAL0400
PGGE3ATAM0250
A.32
A.29
PGGL3ATAL0250
PGGL3ATAL0400
A.29
A.32
PGGP3ATAK0400
PGGP3ATAL0250
A.32
A.29
PGFL2ATAK0400 A.31 PGFN3ATAK0250 A.29 PGFP4ATAJ0400 A.33 PGGE3ATAM0400 A.32 PGGL3ATAM0250 A.29 PGGP3ATAL0400 A.32
PGFL2ATAL0250 A.28 PGFN3ATAK0400 A.32 PGFP4ATAK0250 A.30 PGGE3ATEJ0250 A.29 PGGL3ATAM0400 A.32 PGGP3ATAM0250 A.29
PGFL2ATAL0400 A.31 PGFN3ATAL0250 A.29 PGFP4ATAK0400 A.33 PGGE3ATEJ0400 A.32 PGGL3ATEJ0250 A.29 PGGP3ATAM0400 A.32
A PGFL2ATAM0250
PGFL2ATAM0400
A.28
A.31
PGFN3ATAL0400
PGFN3ATAM0250
A.32
A.29
PGFP4ATAL0250
PGFP4ATAL0400
A.30
A.33
PGGE3ATEK0250
PGGE3ATEK0400
A.29
A.32
PGGL3ATEJ0400
PGGL3ATEK0250
A.32
A.29
PGGP3ATEJ0250
PGGP3ATEJ0400
A.29
A.32
PGFL2ATEJ0250 A.28 PGFN3ATAM0400 A.32 PGFP4ATAM0250 A.30 PGGE3ATEL0250 A.29 PGGL3ATEK0400 A.32 PGGP3ATEK0250 A.29
PGFL2ATEJ0400 A.31 PGFN3ATEJ0250 A.29 PGFP4ATAM0400 A.33 PGGE3ATEL0400 A.32 PGGL3ATEL0250 A.29 PGGP3ATEK0400 A.32
PGFL2ATEK0250 A.28 PGFN3ATEJ0400 A.32 PGFP4ATEJ0250 A.30 PGGE3ATEM0250 A.29 PGGL3ATEL0400 A.32 PGGP3ATEL0250 A.29
PGFL2ATEK0400 A.31 PGFN3ATEK0250 A.29 PGFP4ATEJ0400 A.33 PGGE3ATEM0400 A.32 PGGL3ATEM0250 A.29 PGGP3ATEL0400 A.32
B PGFL2ATEL0250
PGFL2ATEL0400
A.28
A.31
PGFN3ATEK0400
PGFN3ATEL0250
A.32
A.29
PGFP4ATEK0250
PGFP4ATEK0400
A.30
A.33
PGGE4ATAJ0250
PGGE4ATAJ0400
A.30
A.33
PGGL3ATEM0400
PGGL4ATAJ0250
A.32
A.30
PGGP3ATEM0250
PGGP3ATEM0400
A.29
A.32
PGFL2ATEM0250 A.28 PGFN3ATEL0400 A.32 PGFP4ATEL0250 A.30 PGGE4ATAK0250 A.30 PGGL4ATAJ0400 A.33 PGGP4ATAJ0250 A.30
PGFL2ATEM0400 A.31 PGFN3ATEM0250 A.29 PGFP4ATEL0400 A.33 PGGE4ATAK0400 A.33 PGGL4ATAK0250 A.30 PGGP4ATAJ0400 A.33
PGFL2ATSB0250 A.28 PGFN3ATEM0400 A.32 PGFP4ATEM0250 A.30 PGGE4ATAL0250 A.30 PGGL4ATAK0400 A.33 PGGP4ATAK0250 A.30
C PGFL2ATSB0400
PGFL2ATSE0250
A.31
A.28
PGFN3ATSB0250
PGFN3ATSB0400
A.29
A.32
PGFP4ATEM0400
PGFP4ATSB0250
A.33
A.30
PGGE4ATAL0400
PGGE4ATAM0250
A.33
A.30
PGGL4ATAL0250
PGGL4ATAL0400
A.30
A.33
PGGP4ATAK0400
PGGP4ATAL0250
A.33
A.30
PGFL2ATSE0400 A.31 PGFN3ATSE0250 A.29 PGFP4ATSB0400 A.33 PGGE4ATAM0400 A.33 PGGL4ATAM0250 A.30 PGGP4ATAL0400 A.33
PGFL2ATSF0250 A.28 PGFN3ATSE0400 A.32 PGFP4ATSE0250 A.30 PGGE4ATEJ0250 A.30 PGGL4ATAM0400 A.33 PGGP4ATAM0250 A.30
PGFL2ATSF0400 A.31 PGFN3ATSF0250 A.29 PGFP4ATSE0400 A.33 PGGE4ATEJ0400 A.33 PGGL4ATEJ0250 A.30 PGGP4ATAM0400 A.33
D PGFL2ATSH0250
PGFL2ATSH0400
A.28
A.31
PGFN3ATSF0400
PGFN3ATSH0250
A.32
A.29
PGFP4ATSF0250
PGFP4ATSF0400
A.30
A.33
PGGE4ATEK0250
PGGE4ATEK0400
A.30
A.33
PGGL4ATEJ0400
PGGL4ATEK0250
A.33
A.30
PGGP4ATEJ0250
PGGP4ATEJ0400
A.30
A.33
PGFL3ATAJ0250 A.29 PGFN3ATSH0400 A.32 PGFP4ATSH0250 A.30 PGGE4ATEL0250 A.30 PGGL4ATEK0400 A.33 PGGP4ATEK0250 A.30
PGFL3ATAJ0400 A.32 PGFN4ATAJ0250 A.30 PGFP4ATSH0400 A.33 PGGE4ATEL0400 A.33 PGGL4ATEL0250 A.30 PGGP4ATEK0400 A.33
PGFL3ATAK0250 A.29 PGFN4ATAJ0400 A.33 PGFY3ATDU0600 A.34 PGGE4ATEM0250 A.30 PGGL4ATEL0400 A.33 PGGP4ATEL0250 A.30
PGFL3ATAK0400 A.32 PGFN4ATAK0250 A.30 PGGC2ATAJ0250 A.28 PGGE4ATEM0400 A.33 PGGL4ATEM0250 A.30 PGGP4ATEL0400 A.33
E PGFL3ATAL0250
PGFL3ATAL0400
A.29
A.32
PGFN4ATAK0400
PGFN4ATAL0250
A.33
A.30
PGGC2ATAJ0400
PGGC2ATAK0250
A.31
A.28
PGGH2ATAJ0250
PGGH2ATAJ0400
A.28
A.31
PGGL4ATEM0400
PGGN2ATAJ0250
A.33
A.28
PGGP4ATEM0250
PGGP4ATEM0400
A.30
A.33
PGFL3ATAM0250 A.29 PGFN4ATAL0400 A.33 PGGC2ATAK0400 A.31 PGGH2ATAK0250 A.28 PGGN2ATAJ0400 A.31 PGGS0250 B.23
PGFL3ATAM0400 A.32 PGFN4ATAM0250 A.30 PGGC2ATAL0250 A.28 PGGH2ATAK0400 A.31 PGGN2ATAK0250 A.28 PGGS0400 B.23
PGFL3ATEJ0250 A.29 PGFN4ATAM0400 A.33 PGGC2ATAL0400 A.31 PGGH2ATAL0250 A.28 PGGN2ATAK0400 A.31 PGGS0500 B.23
F PGFL3ATEJ0400
PGFL3ATEK0250
A.32
A.29
PGFN4ATEJ0250
PGFN4ATEJ0400
A.30
A.33
PGGC2ATAM0250
PGGC2ATAM0400
A.28
A.31
PGGH2ATAL0400
PGGH2ATAM0250
A.31
A.28
PGGN2ATAL0250
PGGN2ATAL0400
A.28
A.31
PGGS0630
PGJB
B.23
C.10
PGFL3ATEK0400 A.32 PGFN4ATEK0250 A.30 PGGC2ATEJ0250 A.28 PGGH2ATAM0400 A.31 PGGN2ATAM0250 A.28 PGJL3 C.10
PGFL3ATEL0250 A.29 PGFN4ATEK0400 A.33 PGGC2ATEJ0400 A.31 PGGH2ATEJ0250 A.28 PGGN2ATAM0400 A.31 PGJL4 C.10
PGFL3ATEL0400 A.32 PGFN4ATEL0250 A.30 PGGC2ATEK0250 A.28 PGGH2ATEJ0400 A.31 PGGN2ATEJ0250 A.28 PGJM3 C.10
PGFL3ATEM0250 PGFN4ATEL0400 PGGC2ATEK0400 PGGH2ATEK0250 PGGN2ATEJ0400 PGJM4
G PGFL3ATEM0400
A.29
A.32 PGFN4ATEM0250
A.33
A.30 PGGC2ATEL0250
A.31
A.28 PGGH2ATEK0400
A.28
A.31 PGGN2ATEK0250
A.31
A.28 PGJS3
C.10
C.10
PGFL3ATSB0250 A.29 PGFN4ATEM0400 A.33 PGGC2ATEL0400 A.31 PGGH2ATEL0250 A.28 PGGN2ATEK0400 A.31 PGJS4 C.10
PGFL3ATSB0400 A.32 PGFN4ATSB0250 A.30 PGGC2ATEM0250 A.28 PGGH2ATEL0400 A.31 PGGN2ATEL0250 A.28 PGJW3 C.10
PGFL3ATSE0250 A.29 PGFN4ATSB0400 A.33 PGGC2ATEM0400 A.31 PGGH2ATEM0250 A.28 PGGN2ATEL0400 A.31 PGJW4 C.10
PGFL3ATSE0400 A.32 PGFN4ATSE0250 A.30 PGGC3ATAJ0250 A.29 PGGH2ATEM0400 A.31 PGGN2ATEM0250 A.28 PGMC2ATAJ0400 A.31
X PGFL3ATSF0250
PGFL3ATSF0400
A.29
A.32
PGFN4ATSE0400
PGFN4ATSF0250
A.33
A.30
PGGC3ATAJ0400
PGGC3ATAK0250
A.32
A.29
PGGH3ATAJ0250
PGGH3ATAJ0400
A.29
A.32
PGGN2ATEM0400
PGGN3ATAJ0250
A.31
A.29
PGMC2ATAK0400
PGMC2ATAL0400
A.31
A.31
PGFL3ATSH0250 A.29 PGFN4ATSF0400 A.33 PGGC3ATAK0400 A.32 PGGH3ATAK0250 A.29 PGGN3ATAJ0400 A.32 PGMC2ATAM0400 A.31
PGFL3ATSH0400 A.32 PGFN4ATSH0250 A.30 PGGC3ATAL0250 A.29 PGGH3ATAK0400 A.32 PGGN3ATAK0250 A.29 PGMC2ATEJ0400 A.31
PGFL4ATAJ0250 A.30 PGFN4ATSH0400 A.33 PGGC3ATAL0400 A.32 PGGH3ATAL0250 A.29 PGGN3ATAK0400 A.32 PGMC2ATEK0400 A.31
PGFL4ATAJ0400 A.33 PGFP2ATAJ0250 A.28 PGGC3ATAM0250 A.29 PGGH3ATAL0400 A.32 PGGN3ATAL0250 A.29 PGMC2ATEL0400 A.31
PGFL4ATAK0250 A.30 PGFP2ATAJ0400 A.31 PGGC3ATAM0400 A.32 PGGH3ATAM0250 A.29 PGGN3ATAL0400 A.32 PGMC2ATEM0400 A.31
PGFL4ATAK0400 A.33 PGFP2ATAK0250 A.28 PGGC3ATEJ0250 A.29 PGGH3ATAM0400 A.32 PGGN3ATAM0250 A.29 PGMC2ATSB0400 A.31
PGFL4ATAL0250 A.30 PGFP2ATAK0400 A.31 PGGC3ATEJ0400 A.32 PGGH3ATEJ0250 A.29 PGGN3ATAM0400 A.32 PGMC2ATSE0400 A.31
PGFL4ATAL0400 A.33 PGFP2ATAL0250 A.28 PGGC3ATEK0250 A.29 PGGH3ATEJ0400 A.32 PGGN3ATEJ0250 A.29 PGMC2ATSF0400 A.31
PGFL4ATAM0250 A.30 PGFP2ATAL0400 A.31 PGGC3ATEK0400 A.32 PGGH3ATEK0250 A.29 PGGN3ATEJ0400 A.32 PGMC2ATSH0400 A.31
PGFL4ATAM0400 A.33 PGFP2ATAM0250 A.28 PGGC3ATEL0250 A.29 PGGH3ATEK0400 A.32 PGGN3ATEK0250 A.29 PGMC3ATAJ0250 A.29
PGFL4ATEJ0250 A.30 PGFP2ATAM0400 A.31 PGGC3ATEL0400 A.32 PGGH3ATEL0250 A.29 PGGN3ATEK0400 A.32 PGMC3ATAJ0400 A.32
PGFL4ATEJ0400 A.33 PGFP2ATEJ0250 A.28 PGGC3ATEM0250 A.29 PGGH3ATEL0400 A.32 PGGN3ATEL0250 A.29 PGMC3ATAK0250 A.29
PGFL4ATEK0250 A.30 PGFP2ATEJ0400 A.31 PGGC3ATEM0400 A.32 PGGH3ATEM0250 A.29 PGGN3ATEL0400 A.32 PGMC3ATAK0400 A.32
PGFL4ATEK0400 A.33 PGFP2ATEK0250 A.28 PGGC4ATAJ0250 A.30 PGGH3ATEM0400 A.32 PGGN3ATEM0250 A.29 PGMC3ATAL0250 A.29

X.10
GuardEon
Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page Cat. no. Page
PGMC3ATAL0400 A.32 PGME4ATAL0250 A.30 PGML2ATAK0400 A.31 PGMN3ATAK0250 A.29 PGMP4ATAJ0400 A.33
PGMC3ATAM0250 A.29 PGME4ATAL0400 A.33 PGML2ATAL0250 A.28 PGMN3ATAK0400 A.32 PGMP4ATAK0250 A.30
PGMC3ATAM0400 A.32 PGME4ATAM0250 A.30 PGML2ATAL0400 A.31 PGMN3ATAL0250 A.29 PGMP4ATAK0400 A.33
PGMC3ATEJ0250 A.29 PGME4ATAM0400 A.33 PGML2ATAM0250 A.28 PGMN3ATAL0400 A.32 PGMP4ATAL0250 A.30
PGMC3ATEJ0400 A.32 PGME4ATEJ0250 A.30 PGML2ATAM0400 A.31 PGMN3ATAM0250 A.29 PGMP4ATAL0400 A.33
PGMC3ATEK0250 A.29 PGME4ATEJ0400 A.33 PGML2ATEJ0250 A.28 PGMN3ATAM0400 A.32 PGMP4ATAM0250 A.30
PGMC3ATEK0400 A.32 PGME4ATEK0250 A.30 PGML2ATEJ0400 A.31 PGMN3ATEJ0250 A.29 PGMP4ATAM0400 A.33
PGMC3ATEL0250 A.29 PGME4ATEK0400 A.33 PGML2ATEK0250 A.28 PGMN3ATEJ0400 A.32 PGMP4ATEJ0250 A.30
PGMC3ATEL0400 A.32 PGME4ATEL0250 A.30 PGML2ATEK0400 A.31 PGMN3ATEK0250 A.29 PGMP4ATEJ0400 A.33
PGMC3ATEM0250 A.29 PGME4ATEL0400 A.33 PGML2ATEL0250 A.28 PGMN3ATEK0400 A.32 PGMP4ATEK0250 A.30
PGMC3ATEM0400 A.32 PGME4ATEM0250 A.30 PGML2ATEL0400 A.31 PGMN3ATEL0250 A.29 PGMP4ATEK0400 A.33
PGMC3ATSB0250 A.29 PGME4ATEM0400 A.33 PGML2ATEM0250 A.28 PGMN3ATEL0400 A.32 PGMP4ATEL0250 A.30
PGMC3ATSB0400 A.32 PGME4ATSB0250 A.30 PGML2ATEM0400 A.31 PGMN3ATEM0250 A.29 PGMP4ATEL0400 A.33
PGMC3ATSE0250 A.29 PGME4ATSB0400 A.33 PGML2ATSB0250 A.28 PGMN3ATEM0400 A.32 PGMP4ATEM0250 A.30

By catalogue number
PGMC3ATSE0400 A.32 PGME4ATSE0250 A.30 PGML2ATSB0400 A.31 PGMN3ATSB0250 A.29 PGMP4ATEM0400 A.33
PGMC3ATSF0250 A.29 PGME4ATSE0400 A.33 PGML2ATSE0250 A.28 PGMN3ATSB0400 A.32 PGMP4ATSB0250 A.30
PGMC3ATSF0400 A.32 PGME4ATSF0250 A.30 PGML2ATSE0400 A.31 PGMN3ATSE0250 A.29 PGMP4ATSB0400 A.33
PGMC3ATSH0250 A.29 PGME4ATSF0400 A.33 PGML2ATSF0250 A.28 PGMN3ATSE0400 A.32 PGMP4ATSE0250 A.30
PGMC3ATSH0400 A.32 PGME4ATSH0250 A.30 PGML2ATSF0400 A.31 PGMN3ATSF0250 A.29 PGMP4ATSE0400 A.33
PGMC4ATAJ0250 A.30 PGME4ATSH0400 A.33 PGML2ATSH0250 A.28 PGMN3ATSF0400 A.32 PGMP4ATSF0250 A.30
PGMC4ATAJ0400 A.33 PGMH2ATAJ0250 A.28 PGML2ATSH0400 A.31 PGMN3ATSH0250 A.29 PGMP4ATSF0400 A.33
PGMC4ATAK0250 A.30 PGMH2ATAJ0400 A.31 PGML3ATAJ0250 A.29 PGMN3ATSH0400 A.32 PGMP4ATSH0250 A.30
PGMC4ATAK0400 A.33 PGMH2ATAK0250 A.28 PGML3ATAJ0400 A.32 PGMN4ATAJ0250 A.30 PGMP4ATSH0400 A.33
PGMC4ATAL0250 A.30 PGMH2ATAK0400 A.31 PGML3ATAK0250 A.29 PGMN4ATAJ0400 A.33 PGQDB3H C.6
PGMC4ATAL0400 A.33 PGMH2ATAL0250 A.28 PGML3ATAK0400 A.32 PGMN4ATAK0250 A.30 PGQDB3M C.6
PGMC4ATAM0250 A.30 PGMH2ATAL0400 A.31 PGML3ATAL0250 A.29 PGMN4ATAK0400 A.33 PGQDB4H C.6
PGMC4ATAM0400 A.33 PGMH2ATAM0250 A.28 PGML3ATAL0400 A.32 PGMN4ATAL0250 A.30 PGQDB4M C.6
PGMC4ATEJ0250 A.30 PGMH2ATAM0400 A.31 PGML3ATAM0250 A.29 PGMN4ATAL0400 A.33 PGWB3 C.8
PGMC4ATEJ0400 A.33 PGMH2ATEJ0250 A.28 PGML3ATAM0400 A.32 PGMN4ATAM0250 A.30 PGWB4 C.8
PGMC4ATEK0250 A.30 PGMH2ATEJ0400 A.31 PGML3ATEJ0250 A.29 PGMN4ATAM0400 A.33 PGWM C.8
PGMC4ATEK0400 A.33 PGMH2ATEK0250 A.28 PGML3ATEJ0400 A.32 PGMN4ATEJ0250 A.30 PGWN C.8
PGMC4ATEL0250 A.30 PGMH2ATEK0400 A.31 PGML3ATEK0250 A.29 PGMN4ATEJ0400 A.33 PGWT C.8
PGMC4ATEL0400 A.33 PGMH2ATEL0250 A.28 PGML3ATEK0400 A.32 PGMN4ATEK0250 A.30 PICM B.18
PGMC4ATEM0250 A.30 PGMH2ATEL0400 A.31 PGML3ATEL0250 A.29 PGMN4ATEK0400 A.33 PIOMODE B.18
PGMC4ATEM0400 A.33 PGMH2ATEM0250 A.28 PGML3ATEL0400 A.32 PGMN4ATEL0250 A.30 PNHM1 C.6
PGMC4ATSB0250 A.30 PGMH2ATEM0400 A.31 PGML3ATEM0250 A.29 PGMN4ATEL0400 A.33 PNHM2 C.6
PGMC4ATSB0400
PGMC4ATSE0250
A.33
A.30
PGMH2ATSB0250
PGMH2ATSB0400
A.28
A.31
PGML3ATEM0400
PGML3ATSB0250
A.32
A.29
PGMN4ATEM0250
PGMN4ATEM0400
A.30
A.33
PNHM3
PNHM4
C.6
C.6
Intro
PGMC4ATSE0400 A.33 PGMH2ATSE0250 A.28 PGML3ATSB0400 A.32 PGMN4ATSB0250 A.30 PPRLY B.18
PGMC4ATSF0250 A.30 PGMH2ATSE0400 A.31 PGML3ATSE0250 A.29 PGMN4ATSB0400 A.33 PPSAA B.23
PGMC4ATSF0400 A.33 PGMH2ATSF0250 A.28 PGML3ATSE0400 A.32 PGMN4ATSE0250 A.30 PRELT B.18
PGMC4ATSH0250
PGMC4ATSH0400
A.30
A.33
PGMH2ATSF0400
PGMH2ATSH0250
A.31
A.28
PGML3ATSF0250
PGML3ATSF0400
A.29
A.32
PGMN4ATSE0400
PGMN4ATSF0250
A.33
A.30
PREMBP
PRSK
B.23
B.18 A
PGME2ATAJ0250 A.28 PGMH2ATSH0400 A.31 PGML3ATSH0250 A.29 PGMN4ATSF0400 A.33 PYCONN B.22
PGME2ATAJ0400 A.31 PGMH3ATAJ0250 A.29 PGML3ATSH0400 A.32 PGMN4ATSH0250 A.30 PZSI B.18
PGME2ATAK0250 A.28 PGMH3ATAJ0400 A.32 PGML4ATAJ0250 A.30 PGMN4ATSH0400 A.33 SC10H C.6
PGME2ATAK0400 A.31 PGMH3ATAK0250 A.29 PGML4ATAJ0400 A.33 PGMP2ATAJ0250 A.28 SC10L C.6
PGME2ATAL0250
PGME2ATAL0400
A.28
A.31
PGMH3ATAK0400
PGMH3ATAL0250
A.32
A.29
PGML4ATAK0250
PGML4ATAK0400
A.30
A.33
PGMP2ATAJ0400
PGMP2ATAK0250
A.31
A.28
SC3H
SC3L
C.6
C.6
B
PGME2ATAM0250 A.28 PGMH3ATAL0400 A.32 PGML4ATAL0250 A.30 PGMP2ATAK0400 A.31 SC4H C.6
PGME2ATAM0400 A.31 PGMH3ATAM0250 A.29 PGML4ATAL0400 A.33 PGMP2ATAL0250 A.28 SC4L C.6
PGME2ATEJ0250 A.28 PGMH3ATAM0400 A.32 PGML4ATAM0250 A.30 PGMP2ATAL0400 A.31 SC5H C.6
PGME2ATEJ0400
PGME2ATEK0250
A.31
A.28
PGMH3ATEJ0250
PGMH3ATEJ0400
A.29
A.32
PGML4ATAM0400
PGML4ATEJ0250
A.33
A.30
PGMP2ATAM0250
PGMP2ATAM0400
A.28
A.31
SC5L
SC6H
C.6
C.6
C
PGME2ATEK0400 A.31 PGMH3ATEK0250 A.29 PGML4ATEJ0400 A.33 PGMP2ATEJ0250 A.28 SC6L C.6
PGME2ATEL0250 A.28 PGMH3ATEK0400 A.32 PGML4ATEK0250 A.30 PGMP2ATEJ0400 A.31 SC7H C.6
PGME2ATEL0400 A.31 PGMH3ATEL0250 A.29 PGML4ATEK0400 A.33 PGMP2ATEK0250 A.28 SC7L C.6
PGME2ATEM0250
PGME2ATEM0400
A.28
A.31
PGMH3ATEL0400
PGMH3ATEM0250
A.32
A.29
PGML4ATEL0250
PGML4ATEL0400
A.30
A.33
PGMP2ATEK0400
PGMP2ATEL0250
A.31
A.28
SC8H
SC8L
C.6
C.6 D
PGME2ATSB0250 A.28 PGMH3ATEM0400 A.32 PGML4ATEM0250 A.30 PGMP2ATEL0400 A.31 SC9H C.6
PGME2ATSB0400 A.31 PGMH3ATSB0250 A.29 PGML4ATEM0400 A.33 PGMP2ATEM0250 A.28 SC9L C.6
PGME2ATSE0250 A.28 PGMH3ATSB0400 A.32 PGML4ATSB0250 A.30 PGMP2ATEM0400 A.31 SPSA120 B.23
PGME2ATSE0400 A.31 PGMH3ATSE0250 A.29 PGML4ATSB0400 A.33 PGMP2ATSB0250 A.28 SPSA208 B.23
PGME2ATSF0250
PGME2ATSF0400
A.28
A.31
PGMH3ATSE0400
PGMH3ATSF0250
A.32
A.29
PGML4ATSE0250
PGML4ATSE0400
A.30
A.33
PGMP2ATSB0400
PGMP2ATSE0250
A.31
A.28
SPSA240
SPSA480
B.23
B.23
E
PGME2ATSH0250 A.28 PGMH3ATSF0400 A.32 PGML4ATSF0250 A.30 PGMP2ATSE0400 A.31 SPSA600 B.23
PGME2ATSH0400 A.31 PGMH3ATSH0250 A.29 PGML4ATSF0400 A.33 PGMP2ATSF0250 A.28
PGME3ATAJ0250 A.29 PGMH3ATSH0400 A.32 PGML4ATSH0250 A.30 PGMP2ATSF0400 A.31
PGME3ATAJ0400
PGME3ATAK0250
A.32
A.29
PGMH4ATAJ0250
PGMH4ATAJ0400
A.30
A.33
PGML4ATSH0400
PGMN2ATAJ0250
A.33
A.28
PGMP2ATSH0250
PGMP2ATSH0400
A.28
A.31 F
PGME3ATAK0400 A.32 PGMH4ATAK0250 A.30 PGMN2ATAJ0400 A.31 PGMP3ATAJ0250 A.29
PGME3ATAL0250 A.29 PGMH4ATAK0400 A.33 PGMN2ATAK0250 A.28 PGMP3ATAJ0400 A.32
PGME3ATAL0400 A.32 PGMH4ATAL0250 A.30 PGMN2ATAK0400 A.31 PGMP3ATAK0250 A.29
PGME3ATAM0250 PGMH4ATAL0400 PGMN2ATAL0250 PGMP3ATAK0400
PGME3ATAM0400
A.29
A.32 PGMH4ATAM0250
A.33
A.30 PGMN2ATAL0400
A.28
A.31 PGMP3ATAL0250
A.32
A.29 G
PGME3ATEJ0250 A.29 PGMH4ATAM0400 A.33 PGMN2ATAM0250 A.28 PGMP3ATAL0400 A.32
PGME3ATEJ0400 A.32 PGMH4ATEJ0250 A.30 PGMN2ATAM0400 A.31 PGMP3ATAM0250 A.29
PGME3ATEK0250 A.29 PGMH4ATEJ0400 A.33 PGMN2ATEJ0250 A.28 PGMP3ATAM0400 A.32
PGME3ATEK0400 A.32 PGMH4ATEK0250 A.30 PGMN2ATEJ0400 A.31 PGMP3ATEJ0250 A.29
PGME3ATEL0250
PGME3ATEL0400
A.29
A.32
PGMH4ATEK0400
PGMH4ATEL0250
A.33
A.30
PGMN2ATEK0250
PGMN2ATEK0400
A.28
A.31
PGMP3ATEJ0400
PGMP3ATEK0250
A.32
A.29 The policy of GE is
X
PGME3ATEM0250 A.29 PGMH4ATEL0400 A.33 PGMN2ATEL0250 A.28 PGMP3ATEK0400 A.32
PGME3ATEM0400 A.32 PGMH4ATEM0250 A.30 PGMN2ATEL0400 A.31 PGMP3ATEL0250 A.29 one of continuous
PGME3ATSB0250 A.29 PGMH4ATEM0400 A.33 PGMN2ATEM0250 A.28 PGMP3ATEL0400 A.32 improvement.
PGME3ATSB0400 A.32 PGMH4ATSB0250 A.30 PGMN2ATEM0400 A.31 PGMP3ATEM0250 A.29 The right is reserved
PGME3ATSE0250 A.29 PGMH4ATSB0400 A.33 PGMN2ATSB0250 A.28 PGMP3ATEM0400 A.32 to alter the design or
PGME3ATSE0400 A.32 PGMH4ATSE0250 A.30 PGMN2ATSB0400 A.31 PGMP3ATSB0250 A.29 any structural details
PGME3ATSF0250 A.29 PGMH4ATSE0400 A.33 PGMN2ATSE0250 A.28 PGMP3ATSB0400 A.32
PGME3ATSF0400 A.32 PGMH4ATSF0250 A.30 PGMN2ATSE0400 A.31 PGMP3ATSE0250 A.29 of the products at any
PGME3ATSH0250 A.29 PGMH4ATSF0400 A.33 PGMN2ATSF0250 A.28 PGMP3ATSE0400 A.32 time without giving
PGME3ATSH0400 A.32 PGMH4ATSH0250 A.30 PGMN2ATSF0400 A.31 PGMP3ATSF0250 A.29 notice.
PGME4ATAJ0250 A.30 PGMH4ATSH0400 A.33 PGMN2ATSH0250 A.28 PGMP3ATSF0400 A.32
PGME4ATAJ0400 A.33 PGML2ATAJ0250 A.28 PGMN2ATSH0400 A.31 PGMP3ATSH0250 A.29
PGME4ATAK0250 A.30 PGML2ATAJ0400 A.31 PGMN3ATAJ0250 A.29 PGMP3ATSH0400 A.32 December 2016
PGME4ATAK0400 A.33 PGML2ATAK0250 A.28 PGMN3ATAJ0400 A.32 PGMP4ATAJ0250 A.30 GE Industrial Solutions

X.11
Smart, Reliable and Secure
GE Energy Connections GE Energy Connections

GE Energy Connections
121543
GuardEon*
with UL catalog
Since Thomas Edison patented the world’s first circuit breaker,
Industrial Solutions has been transforming the future of electrification.
We design electrical solutions at the crossroads of digital and industrial –
smart, rugged and equipped to control electricity from the grid to its point
of use. Every day, we partner with our customers to solve their toughest
energy challenges and reimagine industry in a way that only the world’s
digital industrial company can.

GuardEon - with UL catalog


GE
Industrial Solutions
41 Woodford Avenue
Plainville, CT 06062
1-800-431-7867

DET-886
* Trademark of General Electric Company
geindustrial.com © Copyright GE Industrial Solutions 2016 geindustrial.com

You might also like