Safety Light Curtain Sensor: Salient Features
Safety Light Curtain Sensor: Salient Features
XLC
Proximity
Sensors
Photoelectric
SALIENT FEATURES
Sensors
20mm beam gap
Blanking Function*
Measurement
Self-Checking Circuit
Dual PNP / NPN Outputs
Sensors
Dust and Vibration Resistant
Status indication for each beam
Sensors
Model Number Legend
1 2 3 4 5
1. Series 5. Muting
XLC _: No Muting (leave blank)
M: With Muting
2. Type
Control
20: 20mm Beam Gap #. Accessories included
Mounting Kit : 1 Set
3. Protective Height
Test Object : 1 No.
200: 200 mm
Connector Cable : 1 Pair
320: 320 mm Weighing
520: 520 mm
* Optional Internal/ External Muting
4. Output **Upto 15m Sensing Available for
Special Requirement
N2: Dual NPN Outputs
P2: Dual PNP Outputs
Automation
Example:
XLC-20-200N2
XLC Series - 20mm beam gap - 200mm protective height, Dual NPN outputs
www.inno.sg/xlc
01
Product Highlights XLC
Proximity
Sensors
the beam that needs muting and press the mute disturbances both visible and infra-red do not
button on top of the receiver to activate muting. Same interfere with the functioning of the light currain.
Sensors
for removing muting. No more messy cables or The sensor is protected against interference by
complicated software for enabling muting. external noise thus ensuring that the outputs continue
to function even under noise prone environments.
Measurement
♦ Dual Outputs
Dual PNP or NPN outputs of 100mA rating are provided for fail safe
Sensors
operation. Seperate output LEDs are provided for both the outputs.
RED when there is no interuption, OFF when beam(s) are
interupted.
Vision & Safety
♦ Self Test
A self-test is performed to check for errors when the power is
turned ON. Also, the self test is regularly performed (within the
response time) while in operation to check for failures. This
ensures that in event of a fault in the sensor or circuits the output
immediately switches off preventing any accidents..
♦ Reduce Down-time
Heavy duty connectors are provided so that the faulty sensor can
be replaced with minimum downtime.
Also the transmitters & receivers are independent and can be
replaced seperately.
Automation
♦ Easy Alignment!
Easy to install and may be mounted in amy position with
non-critical alignment between sensors. Once the transmitter and
receiver are aligned, output LED turns ON (Red).
Components
www.inno.sg/xlc
02
Ratings and Specifications XLC
Proximity
Sensors
NPN Output XLC-20-200N2-_ XLC-20-320N2-_ XLC-20-520N2-_
*Models
PNP Output XLC-20-200P2-_ XLC-20-320P2-_ XLC-20-520P2-_
Photoelectric
Detection Capability Opaque objects min. 22mm dia.
Sensors
Beam Gap (Resolution) 20mm (0.79")
No. of Beams 10 16 26
Measurement
Sensing Range 3000mm
Sensors
Offset Angle Horizontal: ± 5° ; Vertical: ± 1.2° max.
Response Time Startup Time: 2 sec. max.; Response- ON to OFF: 10ms; OFF to ON: 75ms approx.
Sensors
Dual Light ON outputs provided; to be connected to a safety controller or force guided electromechanical safety
Operation Mode
relay to confirm to Safety standards
Protection Circuits Reverse polarity, Output short circuit protection; Self-check for failure alarm
Control Output Rating Load Voltage: max. 30 VDC; Load Current: max 100mA
Control
Vibration Resistance Malfunction: 10 to 55 Hz, Multiple amplifude of 0.7mm, 20 sweeps (1 octave/min) in X, Y, Z directions; 1hr/ Axis
Shock Resistance 10 G
Environmental Illuminance 500 lux max. (light opposite to receiver); if at 20° angle, Sunlight: 5,000 lux, Lamp: 3,000 lux
Ambient Temperature Operation: -10° ~ 55°C; Storage: -15° ~ 70°C (non- freezing; non- condensing)
Emitter 5 meters, 3 core, Oil Resistant PVC, bending radius - R5 mm; 190g
Connector
Cables* 3 meters, 5 core, Oil Resistant PVC, bending radius - R5 mm; 140g
Receiver
* Note:
1) Sensing Distance is mentioned under standard testing conditions and standard test object with an ambient illumination of 2000 lux.
2) Sensing Distance of more than 3 meters upto 15meters is also available against special order.
3) The cable length can be extended safely upto 30meters, the output may malfunction if the length of the cable is extended beyond this limit.
Components
www.inno.sg/xlc
03
Sensor Dimension Drawing XLC
Proximity
Sensors
Ø27 12.5
Sensors
M3 Screws
7
Ø2
C
7.5
B
Measurement
• Rear
Sensors
Ø27
Ø18
Ø15
Earthing
Terminal
Vision & Safety
E A F
Sensors
14
• Mounting Nut
6mm, M5 Screw 12
12
• Test Object
D 200mm, Ø32mm OD
PVC Tube
Ø15
Ø18
Control
Model A B C D E F
Weighing
www.inno.sg/xlc
04
Connections XLC
Proximity
Sensors
Emitter Receiver
Photoelectric
Sensors
Sensing
Target
Earth Earth
Measurement
Brown Brown
Sensors
NPN - NC NPN - NC
Black
Grey
PNP - NC PNP - NC
Blue White (Syncronisation) Blue
ON
Power
OFF
Blocked
Object
Unblocked
ON
Blocked Beam LED
OFF
Control
ON (Red)
Output 1 LED
OFF
ON
Weighing
Control Output 1
OFF
ON (Red)
Output 2 LED
OFF
Automation
ON
Control Output 2
OFF
ON
Machine Operation
OFF
Components
www.inno.sg/xlc
05
Input/ Output Circuit Diagram XLC
Proximity
Sensors
Indication
Load
RECEIVER
Brown
Receiver
Output 2 Grey Main Circuit 2
Emitter
Main Circuit Load
Measurement
Output 1 Black
Receiver
Sensors
Main Circuit 1
Blue
Indication
0V Blue
Vision & Safety
Synchronisation line
White
+24 VDC Brown
White
TRANSMITTER
Indication
RECEIVER
Brown
Output 1 Black
Receiver
Load Main Circuit 1
Control
Blue
Indication
0V Blue
♦ Vibration Damper
The light curtain sensor is designed to withstand upto a maximum of 10G shock and vibration
of 1mm at 55Hz. This statisfies the general installation environment’s requirements.
Automation
However if the sensor is to be installed in places with high shock and vibration levels like
power & axial presses is it advisable to mount the sensor using vibration dampers.
www.inno.sg/xlc
06
Mounting and Adjustments XLC
Proximity
Sensors
♦ Alignment
Tx Rx
Place the transmitter and receiver facing each other and connect to
power.If all/ any of the alignment LEDs in the receiver glows the sensor
Photoelectric
is not properly aligned.
Sensors
Adjust the sensor by moving/ rotating along the vertical and horizontal
axis till the alignment LEDs of all the beams go OFF.
Under this condition both the Output LEDs turn ON indicating proper
alignment.
Measurement
♦ Blanking/ Fixed Muting
Sensors
One or more beams of the sensor can be blanked using the pushbutton provided in the top of the receiver*.
Blanking: Remove Blanking:
Block the beam that need not be sensed on the transmit- To remove the blanking, press and hold the blanking
ter. You will see the corresponding Beam’s LED turn ON pushbutton, while keeping the sensors aligned and
Sensors
turns on again. Now the blanked beam LED will remain removed.
ON, this however will have no bearing on the output.
NOTE: To access the pushbutton, the top cover of the receiver has to be removed.
*: Only for models with muting function.
Control
Weighing
Automation
www.inno.sg
S-2, Guindy Industrial Estate
Chennai - 600 032. Ph: 4353 8888 © INNO, Rights Reserved
Email: info@intechchennai.com
Components
www.inno.sg/xlc
07