Controlling Forces Wind Factor = 1.

00
Horizontal Shear (V) = 45.67 kN
Vertical (P) = 125.28 kN Compression
Moment (M) = 586 kNm

Column Section
Grade = A36
Tensile Strength (Fu) = 40.00 kN/cm2
Yeild Stress (Fy) = 24.80 kN/cm2
Width Thk.
Top Flange (bf1) (tf1) = 250 15 mm
Web (dw) (tw) = 800 8 mm
Bottom Flange (bf2) (tf2) = 250 15 mm

Connection Details
Connection Code = FC-3224
Bolt Grade = A490
Tensile Strength (Fu) = 112.82 kN/cm2
Allowable Tensile Stress (Ft) = 37.23 kN/cm2
Allowable Shear Stress (Fv) = 19.18 kN/cm2
Bolt Diameter (db) = 24 mm
Number of Bolts (n) = 32 mm
Bolt Center to Flange Outside (Cw) = 60 mm
Bolt Center to Plate Edge (ed1) = 55 mm (Along Length)
Bolt Center to Plate Edge (ed2) = 60 mm (Along Width)
Bolt Pitch (p) = 120 mm
Bolt Gauge (g) = 120 mm
Base Plate Length (N) = 1060 mm
Base Plate Width (B) = 470 mm
Distance Edge to CG of Bolts (m) = 235 mm
Bolt CG to Center of Column (f) = 295 mm

Estimate
Weight of Connection Plates = 140.51 kgs.
Weight of Anchor Bolts = 98.11 kgs.
238.62 kgs.
Concrete Data
Mix Grade = M25
Compressive Strength (f c') = 2.50 kN/cm2

Weld Data
For E70XX Electrode (Fu) = 48.23 kN/cm2
Allowable Stress in weld = 0.3 x Fu kN/cm2
Allowable Stress in weld (Fw) = 14.47 kN/cm2

Anchor Bolt
Force in Bolt Group = P / 2 ± M / ( dw + tf1 / 2 + tf2 / 2 )
Compression (C) = 781.66 kN
Tension (T) = 656.38 kN

Force per Bolt


Compression / Bolt (Cb) = 48.85 kN 2C/n
Tension / Bolt (Tb) = 41.02 kN 2T/n
Shear / Bolt = 1.43 kN V/n
Compression Capacity = 168.43 kN Fc x Ab
Tensile Capacity = 168.43 kN Ft x Ab
Shear Capacity = 86.77 kN Fv x Ab
Pull Out Capacity = 50.07 kN [ ( p x db ) x L e ] x u x n
Calculated Shear Stress / Bolt (f v) = 0.32 kN/cm2 V / Ab n
Allowable Tensile Stress with Shear (T s) = 37.23 kN/cm2 [ ( 0.43 Fu ) - ( 1.8 fv ) ]
Tension Capacity with Shear = 168.43 kN Ts x Ab x n

Base Plate
Dimension (a) = 60 mm g/2
Dimension (b) = 60 mm Cw
Bolt Force to Flange = a3 / ( a3 + b3 ) x Max (Tb, Cb)
Bolt Force to Flange (Pfb) = 24.43 kN
Effective width along Flange (bfm) = 120 mm 2 Cw
Moment (Mf) = 1.47 kNm Pfb x Cw
Plate Thickness Required (tp) = sqrt ( 6 M / 0.75 Fy bfm )
Plate Thickness Required (tp) = 19.85 mm Use 20 mm thk. Plate
Allowable Tensile Stress in Flange = 14.88 kN/cm2
Total Force in Flange (Pf) = 195.41 kN
Calculated Tensile Stress in Flange = 5.21 kN/cm2 Pf / ( bf x tf )
Size of Flange Fillet Weld Required = 3.82 mm Pf / ( 0.707 x Fw x 2 x bf )
Bolt Force to Web / Gusset = b3 / ( a3 + b3 ) x Max (Tb, Cb)
Bolt Force to Web / Gusset (Pwb) = 24.43 kN
Effective width along Web (bwm) = 120 mm
Moment (Mw) = 1.47 kNm
Plate Thickness Required (tp) = sqrt ( 6 M / 0.75 Fy bwm )
Plate Thickness Required (tp) =19.85 mm Use 20 mm thk. Plate
Total Force in Web / Gusset (Pw) = 97.71 kN
Web Tension Stress = Pw / ( tw x bwm )
Web Tension Stress = 10.18 kN/cm2 Pw / ( bwm x tw )
Size of Web Fillet Weld Required = 3.98 mm Pw / ( 0.707 x Fw x 2 x bwm )
Gusset Plate
Tension Side Flange Gusset
Thickness (ts) = 15 mm
Height (hs) = 250 mm
Length (ls) = 235 mm
Angle (ø) = 46.77 Deg
Dimension (D1) = 205 mm
Tension Force in Gusset (Pg) = Pw / Sin ø
Tension Force in Gusset (Pg) = 134.10 kN
Calculated Tensile Stress = Pg / [ ts x D1 x ( Sin ø )2 ]
Calculated Tensile Stress = 8.21 kN/cm2 Pg / [ ts x D1 x ( Sin ø )2 ]

Compression Side Flange Gusset


Effective Length (Ls) = 198.27 mm
Effective width (De) = 149.37 mm
Effective Area (As) = 22.41 cm2
Ixx = 416.57 cm4 D1 x Sin ø
rxx = 4.31 cm De x ts
k= 0.75 ts x De3 / 12
k Ls / r = 3.45 sqrt ( Ixx / As )
Allowable Compressive Stress = 14.78 kN/cm2
Compression Force in Gusset (Pg) = 134.10 kN
Calculated Compressive Stress = Pg / ( ts x D1 x ( Sin ø )2
Calculated Compressive Stress = 8.21 kN/cm2

Welds to Flange Gusset


Effective Length of Weld (Lw) = 2 D1
Effective Length of Weld (Lw) = 410 mm
Size of Gusset Fillet Weld Required = 3.20 mm

Welds to Column Web for Shear


Effective Length of Weld (Lu) = 560 mm
Size of Web Fillet Weld Required = 0.80 mm