Newlab 300 Pour Point: Automatic Analysers: Newlab Range
Newlab 300 Pour Point: Automatic Analysers: Newlab Range
NewLab 300
Pour Point
CH-6864 Arzo,Mendrisio, Switzerland
Linetronic Technologies SA
ASTM D97 (correlated) Measuring Pour Point Principle The software includes:
ASTM D5853 According to the methods, the sample
Analysis Menu
ASTM D5950 is cooled down at a specified rate and,
• S tandard method as per ASTM / IP / ISO /
ASTM D6922 at the prescribed temperature intervals,
EN / DIN… norms of reference:
IP 15 the mechanical arm of the analyser lifts
· (internal) with sample pre-heating
IP 441 the test jar from the cooling jacket and tilts
· (external) without sample pre-heating
ISO 3016 it in order to bring it in horizontal position
• Optional methods:
to test the flow of the product.
· T-sample – T-bath (Delta T constant)
Subject The sample movement is detected by
· cooling rate °C / h
Pour Point of petroleum products, the thermal probes (PT100 detection) placed
· selectable bath steps
crude oils, motor and engine oils, additives, above the sample surface which react if
· fast bath
lubricating oils, … touched by the cooled sample.
· selectable tilt out test temperature
Determination (D6922) if an automotive
Measuring Pour Point Devices • A udible alarm and displayed messages
engine oil is homogeneous and will remain
• Two PT100 detection probes placed (at the end of the analysis and in case
so, and if it is miscible with certain standard
on the surface of the product of errors and/or malfunctions)
reference oils after being submitted to a
• M echanical moving arm bringing the test jar Diagnostic Menu
prescribed cycle of temperature changes.
in horizontal position • D irect access to all analog, digital, inputs
and outputs
Measuring Temperature Probe
• S electable value displaying: °C / Volt
• P latinum
resistance PT100 class A
Calibration Menu
Measuring Parameters • Automatic calibration
• Temperatures: in °C of each temperature probe
• Measuring range: -110°C … +100°C • L ast calibration date referred
• Range of analysis: -90°C … +60°C (300/2-SA) to each single probe displayed
• R esolution: 0.06 °C and relative data printable
• A ccuracy: ± 0.1 °C • D isplay of calibration diagram
• R epeatability / Reproducibility: • I nsertion of offset values
as per standards methods or better • S tandard and advanced calibration modes
NewLab 300
Pour Point
www.lin-tech.ch – info@lin-tech.ch
Linetronic Technologies SA
Electrical Supply
• 2 20V ± 15% / 50 to 60 Hz
• 1 15V ± 15% / 60 Hz