Professional Documents
Culture Documents
MOTOMAN Robotics: Work Instruction
MOTOMAN Robotics: Work Instruction
MOTOMAN Robotics: Work Instruction
Work
MOTOMAN Robotics Doc. Number: SSGW-297
Instruction
Date: 06/30/2010
Subject: MedWeld 6000 DX with EIP DCR# 7092
FOR INTERNAL MOTOMAN USE ONLY
2.0 MATERIALS
2.1 256MB Compact Flash card (Part # 144650-2) or compatible
2.2 Medar serial programming pendant DEP-100S
6.2.25 After the beep the “OPTION BOARD” menu is again displayed.
6.2.26 Press ENTER to receive another Modify prompt. Press yes.
6.2.27 Cycle power to the controller to restart normally.
7.15 F3 - Download
7.16 F4 - Exit
7.17 Select Program mode from DEP 100S
7.18 Press F5 - *
7.19 Press F4 - Fieldbus Mapping
7.20 Press 4 – IP Configuration
7.20.1 Set IP Address:
Timer 1 – 10.0.0.10
Timer 2 – 10.0.0.11
Timer 3 – 10.0.0.12
Timer 4 – 10.0.0.13
7.21 F3 - Download
7.22 F4 – Exit
7.23 Press 2 - Map Fieldbus Inputs
7.24 Set inputs to ‘none’
7.25 Press F3 – Download
7.26 Press F4 – Exit
7.27 Press 3 - Map Fieldbus Outputs
7.28 Set outputs to ‘none’
7.29 Press F3 – Download
7.30 Press F4 – Exit
7.31 Cycle Power to the timer
7.32 Verify timer setup
8.3 Verify that the ‘MedWeld’ button is available under the 'PP Application' button and the
program launches. Close the application
8.4 Verify that the MedWeld shortcut button is available and the program launches. Close the
application
Robot
Original Robot
Pendant Pendant
Connection (Windows CE)
IP: 10.0.0.2
IP: 10.0.0.4
Ethernet IP Card
IP: 192.168.0.99
255.255.255.000
Ethernet Switch
EIP Port
IP: 192.168.0.250
255.255.255.000
Medar Timer 1
Ethernet Port
(Half Duplex)
IP: 10.0.0.10
255.255.255.000