Professional Documents
Culture Documents
IJDSIR - e Chain Linking
IJDSIR - e Chain Linking
been tried out like auto polymerizing resin, Bis-GMA, onto the implants intra orally.
• Orthodontic e- chain (Optima flexi) of adequate length The emphasis of this technique is fast, accurate linking of
is cut and stretched repeatedly to reduce its activation. copings and that is the reason why we chose light cure
• Orthodontic separator forceps are used to engage the pattern resin. Many authors have described methods with
square head of the copings with the e-chain and is autopolymerizing resin, flowable composites, bis acryl
continued onto the nearby copings (Fig. 1). One composite provisional materials and bite registration
should be careful not to stretch the e-chains pastes.[1-3,7-10] Our technique can be used with any of these
excessively which can actively pull the copings materials and thus is very versatile. It is advocated by
together and this can be a source of error after some authors that the linked copings have to sectioned and
removal. After engagement, the e-chains should reattached to minimize the effects of polymerization
passively (Fig. 2) link the copings together forming shrinkage.[2,3] The same can be applied to this technique as
the scaffold. well. In vitro studies are being conducted by the authors to
• Light cure pattern resin (Resinlay) is now injected get definitive scientific proof of its accuracy.
onto the scaffold directly intra orally and molded with Conclusion
a hand instrument to ensure even coverage of the e- Multiple and full mouth implant impressions can be
chains (Fig.3). Care should be taken to remove excess physically and mentally demanding for the patients as well
resin and ensure at least 3mm space above the gingiva as the operators. The objective of this technique is to
to allow uninterrupted passage of impression material. simplify the existing protocol without compromising on
• Linking is completed by light curing (Fig. 4) and then its accuracy. Chair side ergonomics are greatly improved
the final impression is made. (Fig. 5) and hence it promises to reduce stress levels of the patient
configuration in sufficient bulk to provide a scaffold.[1-3] 1. Filho HG, Mazaro JV, Vedovatto E, Assunção
Many authors have experimented with different materials WG, dos Santos PH. Accuracy of impression
to be applied on to this scaffold, but very little has been techniques for implants. Part 2 - comparison of
done to find an alternative to floss and orthodontic ligature splinting techniques. J Prosthodont 2009;18:172-6.
wire. Floss and orthodontic wire is time consuming and 2. Di Fiore A, Meneghello R, Savio G, Sivolella
working in a challenging environment like the oral cavity S, Katsoulis J, Stellini E. In Vitro Implant Impression
is especially taxing with such materials. This becomes Accuracy Using a New Photopolymerizing SDR
more of a hassle when patient cooperation and access adds Splinting Material. Clin Implant Dent Relat Res
cheap and easy to use even for beginners. We would like 3. Joseph TM, Ravichandran R, LylajamS, Viswabharan
to emphasize that one precaution that has to be exercised P, Janardhanan K, Rajeev S. Evaluation of positional
is ensuring passivity of the linking. When linked, the e- accuracy in multiple implants using four different
chain scaffold should gently sag which is a reliable splinting materials: An invitro study. J Indian
76
78
Page