Gz>
Water Cooled Reciprocating Chiller
Cooling capacity from 60 ~ 610 KW
High cooling capacity , low power consumption
Intelligent electronics protection for motor compressor
High efficiency condenser
High efficiency dry expansion evaporator
Wide range Temperature Operation from - 40°C to + 20°C
ooooogthermo Q presents the complete line of Water All units are compact , completely factory assembled ,
cooled packaged type_reciprocating Water Chiller . Shape and modular system to be installed as outdoor and
Tanging from 8 to 175 Ton Capacity. weather proof . its can reach on site easy to handling on.
Economical. , easy installation and operation in transportation .
a complete packaged design. Ideal for modern The unit is pressure tested , evacuated and fully charge
Cooling applications in hi rise building , commercial with Refrigerant and includes an initial oil charge .
and office building , shopping mall , hotet , hospital
, and industrial plant .
Programable Electronic Controller
Anhigh performance 16-bit microprocessor guarantees high program running speed
and efficient management of the interfaces andthe expansion boards, including
control of faster transients. The parameters can be protected by various password
levels (manufacturer, user),
All of components in'this system can be connected to pLAN local networks without
requiring additional cards , for the exchanger of data and information . Consequently, distributed control networks
can be created simply and reliability for optimized management of the installation.
is
New generation reciprocating semi hermetic compressor from Copeland -
the word's largest manufacture of semi hermetic compressor . Compact,
Low noise , high efficiency , durable and easy maintenance .
Capable of operating with HCFC Refrigerant, R404, R507, R407,
R134a and R407C
Each Compressor completewith Intelligent electronic for protection
Fully motor protection against by thermal motor temperature control ,
motor overload , phase failure, low / hi voltage and phase sequence
control , low oil pressure protection
5
maw Shell and tube type Condenser , compact and height efficiency heat transfer
with low fin tube.
Copper tubematerial or Copper Nikel for marine use
All condenser complete with slight glass indicator dan stop valve for service.
Ev c
Shell and tube type Evaporator, compact and heightefficiency heat transfer.
All evaporator complete with anti freeze protection and chilled water
temperature sensor toreduce precision chilled water temperature .
‘Manufacture standard TEMA, ASTM .
Ea ind Control Device
Dual pressure switch , to protects hight discharge pressure caused by incorrect installation and low refrigerant
‘suction pressure by refrigerantleak
Freezing protection thermostat , protects against chilled water freezing due to no flow or other causes during
chilled water pipe installation
il pressure safety switch , protects compressor againstloss ofoill pressure
Sight glass , a moisture indicating sight glass is installed in the liquid line, Easy to read color indicator shows
moisture content directly on the spot . This provides mean for easy checking of the system refrigerant charge and
‘condition
Filter drier, Refrigerant circuits are kept free from harmful moisture , sludge , acids and oil contaminating particles
Afilter— drier witch a large effective are allowing for very low pressure drop is provided on each mode.
Flow switch protector for poor cooling water
‘Thermostat control ,Automatically maintains the leaving chilled water temperature at desired levelWATER COOLED PACKAGED CHILLER,
SPECIFICATION DATA
MODEL CW Series [10 AS []15AS | 20AS [SOAS | OAS | S0AS | GOAS | TOAS | BDAS | 100ASZ | i20AS2 | T4OASZ | 180AS3 | 710AS | 240ASA | 2B0ASA
‘COOLNG CAPACTTY= (Ki) 29833 | [sa.sro_| asae1 | 5476 | sna | 115373 | 135s08 | t52sz2 | erase | zzer46 | a7t.s9s | sos0ee | 406.793 | as7se7 | 542.01 | e100
Tipe ‘Semi Hermetic
ro Piston_(_Recirocating
HP wo [is TT» To [7 [| 2x40 [peso [axe] 2x70 [sxe0 T axr0 [axe ax70
compressor | VPhiie 013780
RA a) | mi [fia [wr [| | ws | | 12 | wo [2x78 | em | mx | mo | oxi | wo | a |
tear | 96 [fo too | 205 | ara | eae | se | 00 fuaxsrs | zxamm | oasis | 2x6000] 3x54 | 3x00 | ax5e | 4000
Ssen 1 a ‘
[REFRIGERANT Type RB RAC. RATA,
‘CONDENSER Tne. BITZER -SHELL AND TUBE
No.of Cruit 7 z z Z
‘Condenser WaterFow Rate (waht) | 6a || oat [060 | vane [zine [ 203s [corn] save | «ome | aoe | seme | e550 | e736 | oazs | 1168 | raime
‘Condenser Water Comecton (ct) ON 40 DNS DNB ON 100 DN 125 D1 DN 200 BN 250
‘Condenser Wator Tor vOut 0) 135
[EVAPORATOR Te ‘Thermo SHELL AND TUBE
Ne, of Crt a z a 7
(Chiled Water Flow Raie (wih) 813 || 67 | 775 | 1125 | toa | roms | ouo [oem | somo) ouos | 650 | somo | cose | reso | e318 | roast
(Chiled Water Pressure rep (bar 042 || oz | om | ca {cat | 04s | 9s | 04 | 04 |uoss | os? | ort | om | ca | os | os
Water Connection neh DN: DNS Bua DN 109 DN 125 DNB DN 200
(Child Wier TenbvOut — () eit
“Coning Capacity Based Condenser water | Od - 50°C) 36°0 RefigoanR-22, CW. 12°, OTIC
Tle
RUA Rated load Ano. LRA: Locked Rotor Amp.
DIMENTION
wee |e |o | iw ree L ° H
GWT AS | 1800 [ ino | 1400 | [CA eoASZ ‘sao | 1750 [1800
‘ow 15 AS] 2260} 1.000 1400] [CA 100 AS2 ‘300 | 1750 [1200
‘cw 2 AS | 2760 | i000 | 1400] [CA 120 AS2 ‘ga00 | 1750 [1200
Qw a0_AS_| 2760 | 1000 1400] [CA tad AS2 a0 | 1750 | 1800
‘ow ao_AS_| 2760 | 1000 | 1400] [CA 160 AS3 ‘3200 | 2280 | 1200
‘ow s0_AS_| 3200} 1000 | 1400] [CA 210 AS3 320 | 2250 | 100
cw a AS] 3200] 1000 1400] [CA 240 AS4 3a | 2750 | 1800
ew 70 AS | 3200 [ 1000 | 1400] [CA 280 Asa ‘300 | _2750 [1800Creer
Ozone friendly refrigerant use
Epoxy coating fins or marine type copper fins
Heat recovery from refrigerant hot gas to reduce hot water
type with brine temperature from 2°C to -40°C
Refrigerant Waste Heat Recovery :
The Heat Recovery Unit captures waste heat discharged
from the refrigerantcycle in an Water Chiller or
Air Conditioning system, and transfers that heat into
aHotwatertank, thereby creating low costhotwater
for Hotel , Laundry , Feed water Boiler or Industrial use.
Notonly does the Heat Recovery Unit substantially
reduce the amount of energy required to provide
‘domestic hot water, but italso improves the cooling
efficiency of the Chiller or Air Conditioner itis operating
Heat recovery from refrigerant hotgas to water:
‘Temperature of water can be reach until 70 °C.
® PT. Metalindo Prima Engineering
Heat Transfer Engineering
Office 2
Jl. KH Zainal Mustafa No. 17 - Jakarta ( 13350 ) - Indonesia
Phone 6221 8561234 Fax : 62218513109 -
Website : www.metalindoengineering.com
Email: _info@metalindoengineering.com