Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

SECTION I

GENERAL INFORMATION

Revised: July 2018


Section I - Page # 1
Fx55a ME
800# Class Hammer
for Mini-Excavators
SPECIFICATIONS:
Mounting Style . . . . . . . . . . . . . . . ME Side Plates
Weight . . . . . . . . . . . . . . . . . . . . . 555 lbs. (252 Kg)
Length . . . . . . . . . . . . . . . . . . . . . 54 in. (1372 mm)
Blows/Minute . . . . . . . . . . . . . . . 500 ~ 1100
Acceptable Oil Flow. . . . . . . . . . . . 10.5 ~ 22.5
G.P.M.
Operating Pressure . . . . . . . . . . . . 1740 ~ 2320
P.S.I.
Working Steel Diameter . . . . . . . . . 2.68 in.
Effective Length of Working Steel . . 14.88 in.
Recommended Carrier Size . . . . . . 4.4 ~ 7.0 Tons

Fx55a CP
800# Class Hammer
for 027 Couplers
SPECIFICATIONS:
Mounting Style . . . . . . . . . . . . . . . CP Weldment Brkt
Weight . . . . . . . . . . . . . . . . . . . . . 524 lbs. (238 Kg)
Length . . . . . . . . . . . . . . . . . . . . . 57.29 in. (1455.2 mm)
Blows/Minute . . . . . . . . . . . . . . . 500 ~ 1100
Acceptable Oil Flow. . . . . . . . . . . . 10.5 ~ 22.5
G.P.M.
Operating Pressure . . . . . . . . . . . . 1740 ~ 2320
P.S.I.
Working Steel Diameter . . . . . . . . . 2.68 in.
Effective Length of Working Steel . . 14.88 in.
Recommended Carrier Size . . . . . . 4.4 ~ 7.0 Tons

Section I - Page # 2
Fx55a SS
800# Class Hammer
for Skid-Loader
SPECIFICATIONS:
Mounting Style . . . . . . . . . . . . . . . Rigid Loader Quick Attach
Weight . . . . . . . . . . . . . . . . . . . . . 840 lbs. (381 Kg)
Length . . . . . . . . . . . . . . . . . . . . . 61 in. (1549 mm)
Blows/Minute . . . . . . . . . . . . . . . 500 ~ 1100
Acceptable Oil Flow. . . . . . . . . . . . 10.5 ~ 22.5
G.P.M.
Operating Pressure . . . . . . . . . . . . 1740 ~ 2320
P.S.I.
Working Steel Diameter . . . . . . . . . 2.68 in.
Effective Length of Working Steel . . 14.88 in.
Recommended Carrier Size . . . . . . 4.4 ~ 7.0 Tons

Fx55a FSP
800# Class Hammer
Flanged Side Plates
with Bolt-On Top Cap
SPECIFICATIONS:
Mounting Style . . . . . . . . . . . . . . . Flat Top with Bolt-on Top Cap
Weight . . . . . . . . . . . . . . . . . . . . . 714 lbs. (324 Kg)
Length . . . . . . . . . . . . . . . . . . . . . 60 in. (1524 mm)
Blows/Minute . . . . . . . . . . . . . . . 500 ~ 1100
Acceptable Oil Flow. . . . . . . . . . . . 10.5 ~ 22.5
G.P.M.
Operating Pressure . . . . . . . . . . . . 1740 ~ 2320
P.S.I.
Working Steel Diameter . . . . . . . . . 2.68 in.
Effective Length of Working Steel . . 14.88 in.
Recommended Carrier Size . . . . . . 4.4 ~ 7.0 Tons

Section I - Page # 3
Fx55a Qt
800# Class Hammer
Sound Dampening Box
SPECIFICATIONS:
Mounting Style . . . . . . . . . . . . . . . Box Enclosure with Top Cap
Weight . . . . . . . . . . . . . . . . . . . . . 720 lbs. (327 Kg)
Length . . . . . . . . . . . . . . . . . . . . . 57.5 in. (1461 mm)
Blows/Minute . . . . . . . . . . . . . . . 500 ~ 1100
Acceptable Oil Flow. . . . . . . . . . . . 10.5 ~ 22.5
G.P.M.
Operating Pressure . . . . . . . . . . . . 1740 ~ 2320
P.S.I.
Working Steel Diameter . . . . . . . . . 2.68 in.
Effective Length of Working Steel . . 14.88 in.
Recommended Carrier Size . . . . . . 4.4 ~ 7.0 Tons

Section I - Page # 4
Section I - Page # 5
SAFETY PRECAUTIONS
Before installation or operation of the hydraulic breaker, the operator and
maintenance personnel should read and understand the following safety precautions:
 The safety alert symbol ! means ATTENTION! Your safety is involved!!

 In accordance with the general construction safety standards, no bystanders are


allowed in the vicinity of the breaker while it is in use.
 Stay clear of the breaker while it is in operation. Flying objects can cause severe
injuries, or even death.
 Always wear safety glasses and ear protection when operating the breaker.
 Always wear safety glasses during installation, service or any activities associated
with the breaker.
 Before operating the breaker, read and follow the safety decals located on the
breaker. The opposite page shows these decals.
 Operate the breaker only when the operator is seated in the cabin with full control
of the machine.
 Use the breaker for its intended purpose only.
 Be sure all decals, name plates, serial number tags and the mandatory daily check
list are clearly visible. Clean and replace as necessary.
 When installing or removing the breaker, keep hands and fingers clear of the
mounting pin holes and linkage.
 Make frequent inspections of the breaker and base machine as described in the
"Daily Inspection" section of this manual.
 Never use the breaker as a lifting device.
 Do not make any alterations to the breaker without the authorization of Furukawa
Rock Drill USA’s Product Support Department.
 Anytime service is performed on the breaker, hydraulic pressure in the line must
first be released. Then disconnect the hydraulic lines themselves.
 Never disassemble the breaker without first releasing the gas charges. Failure to
comply can result in serious injuries or death.
 Use only Furukawa Rock Drill USA replacement parts.

!
 Never use hands to search for hydraulic fluid leaks, use a piece of paper or
cardboard. Escaping fluid under pressure can be invisible and can penetrate
the skin and cause a serious injury. If any fluid is injected into your skin,
see a doctor immediately. Injected fluid MUST be surgically removed by a
doctor familiar with this type of injury or gangrene may result.

Section I - Page # 6