Professional Documents
Culture Documents
General Information: Section I
General Information: Section I
GENERAL INFORMATION
Fx55a CP
800# Class Hammer
for 027 Couplers
SPECIFICATIONS:
Mounting Style . . . . . . . . . . . . . . . CP Weldment Brkt
Weight . . . . . . . . . . . . . . . . . . . . . 524 lbs. (238 Kg)
Length . . . . . . . . . . . . . . . . . . . . . 57.29 in. (1455.2 mm)
Blows/Minute . . . . . . . . . . . . . . . 500 ~ 1100
Acceptable Oil Flow. . . . . . . . . . . . 10.5 ~ 22.5
G.P.M.
Operating Pressure . . . . . . . . . . . . 1740 ~ 2320
P.S.I.
Working Steel Diameter . . . . . . . . . 2.68 in.
Effective Length of Working Steel . . 14.88 in.
Recommended Carrier Size . . . . . . 4.4 ~ 7.0 Tons
Section I - Page # 2
Fx55a SS
800# Class Hammer
for Skid-Loader
SPECIFICATIONS:
Mounting Style . . . . . . . . . . . . . . . Rigid Loader Quick Attach
Weight . . . . . . . . . . . . . . . . . . . . . 840 lbs. (381 Kg)
Length . . . . . . . . . . . . . . . . . . . . . 61 in. (1549 mm)
Blows/Minute . . . . . . . . . . . . . . . 500 ~ 1100
Acceptable Oil Flow. . . . . . . . . . . . 10.5 ~ 22.5
G.P.M.
Operating Pressure . . . . . . . . . . . . 1740 ~ 2320
P.S.I.
Working Steel Diameter . . . . . . . . . 2.68 in.
Effective Length of Working Steel . . 14.88 in.
Recommended Carrier Size . . . . . . 4.4 ~ 7.0 Tons
Fx55a FSP
800# Class Hammer
Flanged Side Plates
with Bolt-On Top Cap
SPECIFICATIONS:
Mounting Style . . . . . . . . . . . . . . . Flat Top with Bolt-on Top Cap
Weight . . . . . . . . . . . . . . . . . . . . . 714 lbs. (324 Kg)
Length . . . . . . . . . . . . . . . . . . . . . 60 in. (1524 mm)
Blows/Minute . . . . . . . . . . . . . . . 500 ~ 1100
Acceptable Oil Flow. . . . . . . . . . . . 10.5 ~ 22.5
G.P.M.
Operating Pressure . . . . . . . . . . . . 1740 ~ 2320
P.S.I.
Working Steel Diameter . . . . . . . . . 2.68 in.
Effective Length of Working Steel . . 14.88 in.
Recommended Carrier Size . . . . . . 4.4 ~ 7.0 Tons
Section I - Page # 3
Fx55a Qt
800# Class Hammer
Sound Dampening Box
SPECIFICATIONS:
Mounting Style . . . . . . . . . . . . . . . Box Enclosure with Top Cap
Weight . . . . . . . . . . . . . . . . . . . . . 720 lbs. (327 Kg)
Length . . . . . . . . . . . . . . . . . . . . . 57.5 in. (1461 mm)
Blows/Minute . . . . . . . . . . . . . . . 500 ~ 1100
Acceptable Oil Flow. . . . . . . . . . . . 10.5 ~ 22.5
G.P.M.
Operating Pressure . . . . . . . . . . . . 1740 ~ 2320
P.S.I.
Working Steel Diameter . . . . . . . . . 2.68 in.
Effective Length of Working Steel . . 14.88 in.
Recommended Carrier Size . . . . . . 4.4 ~ 7.0 Tons
Section I - Page # 4
Section I - Page # 5
SAFETY PRECAUTIONS
Before installation or operation of the hydraulic breaker, the operator and
maintenance personnel should read and understand the following safety precautions:
The safety alert symbol ! means ATTENTION! Your safety is involved!!
!
Never use hands to search for hydraulic fluid leaks, use a piece of paper or
cardboard. Escaping fluid under pressure can be invisible and can penetrate
the skin and cause a serious injury. If any fluid is injected into your skin,
see a doctor immediately. Injected fluid MUST be surgically removed by a
doctor familiar with this type of injury or gangrene may result.