Professional Documents
Culture Documents
Brosur Ccsi
Brosur Ccsi
Fiber Cables
Technical Specification
GENERAL
The cable is for outdoor application installed as aerial cable on up to 100-m pole distance (span) or as duct
cable installed inside HDPE sub duct
REFERENCE STANDARDS
The offered fiber optic cable complies to the ITU-T G.652.D, ITU-T G.655.C, ITU-T G.655.D, ITU-T G.657.A1, IEC
60794-3, TIA/ EIA standards.
CONSTRUCTIONS
CABLE STRUCTURE
Fully waterblocked cable
– Each fibers are inserted into thixotropic gel-filled coloured dual – layer thermoplastic (PC-PBT) loose buffer
tubes
– Water ingression protection is applied using swellable compound and tape
All-dielectric cable construction
– Requires no grounding
– Glass reinforced plastic (GRP/FRP) non-metallic, anti buckling central strength element
– Aramid yarns as a tensile strength element
High Density Polyethylene (HDPE) jacket
– Black UV resistant High Density Polyethylene (HDPE) jacket as outer protection
– Good abrasion & scratch resistance
– Excellent weathering and UV resistance
PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER :
ITU-T G.655.C &
Reference Standard ITU-T G.652.D ITU-T G.657.A1
655.D
Non-Zero
Bending-Loss
Dispersion Shifted
Type Single Mode Insensitive Single
(NZDSF) Single
Mode
Mode
Wavelength (nm) 1310 / 1550 1550 1310 / 1550
Attenuation on Finished Cables
0.35 / 0.20 0.215 0.35 / 0.20
(dB/km)
Typical Attenuation (dB/km) 0.35 / 0.19 0.210 0.35 / 0.19
9.2 ± 0.4 / 10.4 ± 9.2 ± 0.4 / 10.4 ±
Mode Field Diameter (µm) 9.60 ± 0.4
0.5 0.5
CABLE PARAMETERS :
ITEM SPECIFICATION
156 –
Fiber Quantity 4 – 30 12 – 60 72 84 – 96 108 – 144 228 – 312
216
Maximum Fibers per
6 12 12 12 12 12 12
Tube
Loose Tube Quantity 5 5 6 8 12 18 26
Number of Active Tubes 1 – 5 1–5 6 7–8 9 – 12 13 – 18 19 – 26
Cable
Diameter 9.0 mm 9.5 mm 10.0 mm 11.5 mm 14.0 mm 14.5 mm 17.5 mm
Cable
(Nominal)
Dimension
Cable Weight 100 130 160 230
60 kg/km 65 kg/km 80 kg/km
(Nominal) kg/km kg/km kg/km kg/km
MECHANICAL CHARACTERISTICS :
ITEM SPECIFICATION
Operating Tensile Strength (Refer to IEC 60794-
2900 N
1-E1)
Minimum Sagging 1% of span distance
Wind Speed (Maximum) 100 km/hour
Crush Strength (Refer to IEC 60794-1-E3) 2500 N/ 100 mm
Impact Strength (Refer to IEC 60794-1-E4) 12 Nm
Kink Strength Radius (Refer to IEC 60794-1-2-
5 x Cable Outside Diameter
E10)
Minimum Bending Radius (Refer to IEC 60794-1-
10 x Cable Outside Diameter
E11)
Torsion (Refer to IEC 60794-1-E7) 30 twists, 2 direction @ 180˚, Load 250N
Water Ingression Resistance (Refer to IEC 60794- Passed with 1-m cable sample, 24 hours,
1-F5B) 1-m water column height pressure
Operating & Storage Temperature Up to 70° C
We are leader in optical fiber cable manufacturer in Indonesia. It is well known in the market
as a producer of premium, high quality products
We produce optical fiber cable manufacturer in Indonesia. It is well known in the market
as a producer of premium, high quality products. It has the capability to produce wide range of
indoor and outdoor cables. Presently it is the only cabler in Indonesia that is capable of producing
submarine cables. Each cable is designed for a different applications and condition. The fibers are
guarantee to be stress free and without strain effects during production, storage and installation.
This is to assure a long cable lifetime and an optimum data-carrying capacities. CCSI factory
has annual production capacity of 1,000,000 fiber Km. The factory is located at Krakatau Industrial
Estate in Cilegon, Banten; whereas, the Sales & Marketing Office is located in Jakarta.
PT Communication Cable Systems Indonesia commits to supply best quality and satisfaction of
its products and services to the customer.
We offer fiber optic project execution, engineering services, instalation, maintenance and all
support to meet different customer needs.
PT Communication Cable Systems Indonesia has been preferred as main supplier in
telecommunication industries, oil & gas industries, power utility, railway transport authority, and
private enterprises.
PT Communication Cable Systems Indonesia by 2007, has renewed its Quality Management
Systems and achieved ISO 9001-2000 Quality Management Sytems Certificate..
Integrity is the quality of being honest and having strong moral principles; moral uprightness.
In everything we do as a company, we consistently uphold that our employees are our greatest
asset.
We believe that great quality is the result of commitment and participation by every project team
member.
At CCSI, we make safety more than just a part of our job, but the way we live, drive and work
CCSI Standard Aerial Figure-8 Optical Fiber Cables
Technical Specification
GENERAL
The cable is for outdoor application installed as overhead between city poles up to 100-m span for aerial
networks.
REFERENCE STANDARDS
The offered fiber optic cable complies to the ITU-T G.652.D, ITU-T G.655.C, ITU-T G.655.D, ITU-T G.657.A1, IEC
60794-3, TIA/ EIA standards.
CONSTRUCTIONS
CABLE STRUCTURE
Fully waterblocked cable
– Each fibers are inserted into thixotropic gel-filled coloured thermoplastic (PC-PBT) loose buffer tubes
– Water ingression protection is applied using swellable compound and tape
Dielectric central strength member
Mode Field Diameter (µm) 9.2 ± 0.4 / 10.4 ± 0.5 9.6 ± 0.4 9.2 ± 0.4 / 10.4 ± 0.5
Cable Diameter
10.0 mm 11.0 mm 11.5 mm 13.0 mm 15.5 mm 16.5 mm 19.0 mm
(Nominal)
MECHANICHAL CHARACTERISTICS :
ITEM SPECIFICATION
Operating Tensile Strength (Refer to IEC 60794-1-E1) 2900 N
Water Ingression Resistance (Refer to IEC 60794-1- Passed with 1-m cable sample, 24 hours,
F5B)
1-m water column height pressure
Operating & Storage Temperature Up to 70° C
Telkom Standard Aerial Figure-8 Optical Fiber Cables
Technical Specification
GENERAL
The cable is for outdoor application installed as overhead between city poles up to 100-m span for aerial
networks.
REFERENCE STANDARDS
The offered fiber optic cable complies to the ITU-T G.652.D, ITU-T G.655.C, ITU-T G.655.D, ITU-T G.657.A1, IEC
60794-3, STEL K-017-2009, TIA/ EIA standards.
CONSTRUCTIONS
CABLE STRUCTURE
Fully waterblocked cable
– Each fibers are inserted into thixotropic gel-filled coloured dual-layer thermoplastic (PC-PBT) loose buffer
tubes
– Water ingression protection is applied using swellable compound and tape
Dielectric central strength member
– Glass reinforced plastic (GRP/FRP) non-metallic, anti buckling central strength element
SZ-stranded
– Isolates fibers from installation and environmental rigors
– The loose buffer tube and fillers are SZ-stranded around FRP and bound with polyester yarns
Supporting Strength Element Figure-8
– Galvanized steel messenger wire 7 x Ø1.2 mm
High Density Polyethylene (HDPE) jacket
– Black UV resistant High Density Polyethylene (HDPE) jacket as outer protection
– Good abrasion & scratch resistance
– Excellent weathering and UV resistance
PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER :
Reference Standard ITU-T G.652.D ITU-T G.655.C ITU-T G.655.D ITU-T G.657.A1
Non-Zero Non-Zero
Bending Loss
Dispersion Dispersion
Type Single Mode Insensitive Single
Shifted (NZDSF) Shifted (NZDSF)
Mode
Single Mode Single Mode
Wavelength (nm) 1310 / 1550 1550 / 1625 1550 / 1625 1310 / 1550
Attenuation on
Finished Cables 0.35 / 0.215 0.215 / 0.30 0.210 / 0.35 0.35 / 0.20
(dB/km)
Typical Attenuation
0.35 / 0.215 0.215 / 0.30 0.210 / 0.35 0.35 / 0.19
(dB/km)
Mode Field Diameter 9.2 ± 0.4 at 1310 9.6 ± 0.4 at 1550 9.6 ± 0.4 at 1550 9.2 ± 0.4 at 1310
(µm) nm nm nm nm
CABLE PARAMETERS :
ITEM SPECIFICATION
Fiber Quantity 4 – 36 24 – 72 60 – 96
Maximum Fibers per Tube 6 12 12
Loose Tube Quantity 6 6 8
Number of Active Tubes 1–6 2–6 5–8
Cable Diameter
12.0 mm 13.0 mm 14.5 mm
Cable (Nominal)
Dimension Cable Height (Nominal) 21.0 mm 22.0 mm 23.5 mm
Cable Weight (Nominal) 200 kg/km 215 kg/km 255 kg/km
MECHANICHAL CHARACTERISTICS :
ITEM SPECIFICATION
Operating Tensile Strength (Refer to IEC 60794-
2900 N
1-E1)
Crush Strength (Refer to IEC 60794-1-E3) 2500 N/ 100 mm
Impact Strength (Refer to IEC 60794-1-E4) 12 Nm
Kink Strength (Refer to IEC 60794-1-2-E10) 10 x Cable Outside Diameter
Minimum Bending Radius (Refer to IEC 60794-1-
15 x Cable Outside Diameter
E11)
Torsion (Refer to IEC 60794-1-E7) 30 twists, 2 direction @ 180˚, Load 250N
Water Ingression Resistance (Refer to IEC 60794- Passed with 1-m cable sample, 24 hours,
1-F5B) 1-m water column height pressure
Operating & Storage Temperature Up to 70° C
CCSI Flame Retardant Flare Flex Optical Fiber Cables
Technical Specification
GENERAL
The cable is applicable for indoor, on cable trays/ ladders including underground installation and inside
conduits.
REFERENCE STANDARDS
The offered fiber optic cable complies to the ITU-T G.652.D, ITU-T G.651, IEC 60794, TIA/ EIA standards.
CONSTRUCTIONS
CABLE STRUCTURE
Fully waterblocked cable
– Each fibers are inserted into thixotropic gel-filled coloured thermoplastic (PC-PBT) loose buffer tubes
– Water ingression protection using swellable material
Central loose tube design
– Single loose tube
Anti-Rodent material
– Provides rodent bite protection
Low Smoke Zero Halogen Flame Retardant (LSZH FR) jacket
– Black UV resistant Low Smoke Zero Halogen Flame Retardant (LSZH FR) sheath as outer protection
– Reduces the amount of toxic and corrosive fume emission
– Other sheathing are available upon request
PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER
Reference Standard ITU-T G.652.D
Type Single Mode
Wavelength (nm) 1310 / 1550
Attenuation on Finished Cables (dB/km) 0.35 / 0.20
Typical Attenuation (dB/km) 0.35 / 0.19
Mode Field Diameter (µm) 9.2 ± 0.4 / 10.4 ± 0.5
FIBER PARAMETERS OF MULTIMODE OPTICAL FIBER
Core / Cladding Diameter (µm) 50/125 62.5/125
Reference Standard ITU-T G.651.1 TIA – EIA – 568 – B.3
Wavelength (nm) 850 / 1300 850 / 1300
Attenuation on Finished Cables (dB/km) 3.0 / 0.8 3.5 / 1.5
Modal Bandwidth – length product for
500 / 500 160 / 500
overfilled launch (MHz.km)
Multimode OM3 and OM4 fibers are available upon request.
CABLE PARAMETERS
ITEM SPECIFICATION
Fiber Quantity 4 – 12
Loose Tube Quantity 1
Cable Outer Diameter (Nominal) 6.0 mm
Dimension Weight (Nominal) 45 kg/km
MECHANICAL CHARACTERISTICS
ITEM SPECIFICATION
Operating Tensile Strength (Refer to IEC
1000 N
60794-1-E1)
Crush Strength (Refer to IEC 60794-1-E3) 1000 N/ 250 mm
Impact Strength (Refer to IEC 60794-1-E4) 5 Nm
Kink Strength (Refer to IEC 60794-1-E11) 5 x Cable Outside Diameter
Minimum Bending Radius (Refer to IEC
10 x Cable Outside Diameter
60794-1-E11)
Water Ingression Resistance (Refer to IEC Passed with 1-m cable sample, 24 hours,
60794-1-F5B) 1-m water column height pressure
Operating & Storage Temperature Up to 70° C
Corrugated Steel Tape Armored Direct Buried Single
Jacket Optical Fiber Cables
Technical Specification
GENERAL
The cable is for outdoor, underground inside HDPE ducts. The installation may use air-assisted (air-blown)
method, water pressure-floating or manual pulling.
REFERENCE STANDARDS
The offered fiber optic cable complies to the the ITU-T G.652.D, ITU-T G.654.B, ITU-T G.654.C, ITU-T G.655.C,
ITU-T G.655.D, ITU-T G.657.A1, IEC 60794-3, TIA/ EIA standards. Fiber type is optional, following to the
customer request.
CONSTRUCTIONS
CABLE STRUCTURE
Fully waterblocked
– Each fibers are inserted into thixotropic gel-filled coloured dual – layer thermoplastic (PC-PBT) loose buffer
tubes
– Water ingression protection is applied using swellable compound and tape
Dielectric central strength member
– Glass reinforced plastic (GRP/FRP) non-metallic, anti buckling central strength element
SZ-stranded
– Isolates fibers from installation and environmental rigors
– The loose buffer tube and fillers are SZ-stranded around FRP and bound with polyester yarns
Corrugated Steel Tape Armor
– Provides rodent bite protection for direct buried applications
High Density Polyethylene (HDPE) jacket
– Black UV resistant High Density Polyethylene (HDPE) jacket as outer protection
– Good abrasion & scratch resistance
– Excellent weathering and UV resistance
PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER :
ITU-T G.655.C &
Reference Standard ITU-T G.652.D ITU-T G.657.A1
655.D
Non-Zero
Bending-Loss
Dispersion Shifted
Type Single Mode Insensitive Single
(NZDSF) Single
Mode
Mode
Wavelength (nm) 1310 / 1550 1550 1310 / 1550
Attenuation on Finished Cables
0.35 / 0.20 0.215 0.35 / 0.20
(dB/km)
Typical Attenuation (dB/km) 0.35 / 0.19 0.210 0.35 / 0.19
9.2 ± 0.4 / 10.4 ± 9.2 ± 0.4 / 10.4 ±
Mode Field Diameter (µm) 9.60 ± 0.4
0.5 0.5
FIBER PARAMETERS OF MULTIMODE OPTICAL FIBER :
Core / Cladding Diameter (µm) 50/125 62.5/125
Reference Standard ITU-T G.651.1 TIA – EIA – 568 – B.3
Wavelength (nm) 850 / 1300 850 / 1300
Attenuation on Finished Cables
3.0 / 0.8 3.5 / 1.5
(dB/km)
Modal Bandwidth – length product
500 / 500 160 / 500
for overfilled launch (MHz.km)
Multimode OM3 and OM4 fibers are available upon request.
CABLE PARAMETERS :
ITEM SPECIFICATION
156 –
Fiber Quantity 4 – 30 12 – 60 72 84 – 96 108 – 144 228 – 312
216
Maximum Fibers per
6 12 12 12 12 12 12
Tube
Loose Tube Quantity 5 5 6 8 12 18 26
Number of Active Tubes 1 – 5 1–5 6 7–8 9 – 12 13 – 18 19 – 26
Cable
Diameter 10.5 mm 11.0 mm 12.5 mm 13.5 mm 16.0 mm 16.5 mm 19.0 mm
Cable
(Nominal)
Dimension
Cable Weight 105 115 145 170 235 250 330
(Nominal) kg/km kg/km kg/km kg/km kg/km kg/km kg/km
MECHANICAL CHARACTERISTICS :
ITEM SPECIFICATION
Operating Tensile Strength (Refer to IEC 60794-1-
2900 N
E1)
Crush Strength (Refer to IEC 60794-1-E3) 4500 N/ 100 mm
Impact Strength (Refer to IEC 60794-1-E4) 12 Nm
Kink Strength Radius (Refer to IEC 60794-1-2-E10) 5 x Cable Outside Diameter
Minimum Bending Radius (Refer to IEC 60794-1-
10 x Cable Outside Diameter
E11)
Torsion (Refer to IEC 60794-1-E7) 30 twists, 2 direction @ 180˚, Load 250N
Water Ingression Resistance (Refer to IEC 60794- Passed with 1-m cable sample, 24 hours,
1-F5B) 1-m water column height pressure
Operating & Storage Temperature Up to 70° C
Telkom Standard Direct Buried Optical Fiber Cables
Technical Specification
GENERAL
The cable is applicable for outdoor, direct burial, inside HDPE ducts, or on cable trays or on cable ladders.
REFERENCE STANDARDS
The offered fiber optic cable complies to the ITU-T G.652.D, ITU-T G.655.C, ITU-T G.655.D, IEC 60794-3, STEL
K-016-2009 versi 2.1, TIA/ EIA standards.
CONSTRUCTIONS
CABLE STRUCTURE
Fully waterblocked
– Each fibers are inserted into thixotropic gel-filled coloured dual – layer thermoplastic (PC-PBT) loose buffer
tubes
– Water ingression protection is applied using swellable compound and tape
Dielectric central strength member
– Glass reinforced plastic (GRP/FRP) non-metallic, anti buckling central strength element
SZ-stranded
– Isolates fibers from installation and environmental rigors
– The loose buffer tube and fillers are SZ-stranded around FRP and bound with polyester yarns
Double Polymer Coated Aluminium Tape
– Aluminium tape as a mositure barrier
Corrugated Steel Tape Armor
– Provides rodent bite protection for direct buried applications
High Density Polyethylene (HDPE) jacket
– Black UV resistant High Density Polyethylene (HDPE) jacket as outer & inner protection
– Good abrasion & scratch resistance
– Excellent weathering and UV resistance
PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER
ITU-T G.655.C &
Reference Standard ITU-T G.652.D ITU-T G.657.A1
655.D
Non-Zero
Bending-Loss
Dispersion Shifted
Type Single Mode Insensitive Single
(NZDSF) Single
Mode
Mode
Wavelength (nm) 1310 / 1550 1550 1310 / 1550
Attenuation on Finished Cables
0.35 / 0.20 0.215 0.35 / 0.20
(dB/km)
Typical Attenuation (dB/km) 0.35 / 0.19 0.210 0.35 / 0.19
9.2 ± 0.4 at 1310 9.2 ± 0.4 at 1310
9.60 ± 0.4 at 1550
Mode Field Diameter (µm) nm 10.4 ± 0.5 at nm 10.4 ± 0.5 at
nm
1550 nm 1550 nm
CABLE PARAMETERS
ITEM SPECIFICATION
Fiber Quantity 4 – 36 24 – 72 60 – 96 120 – 144 120 – 216 240 – 264
Maximum Fibers per
6 12 12 12 12 12
Tube
Loose Tube Quantity 6 6 8 12 18 22
Number of Active Tubes 1–6 2–6 5–8 10 – 12 10 – 18 20 – 22
Diameter
17.0 mm 18.0 mm 20.0 mm 22.5 mm 23.5 mm 25.0 mm
Cable (Nominal)
Dimension Weight
255 kg/km 285 kg/km 320 kg/km 435 kg/km 450 kg/km 520 kg/km
(Nominal)
MECHANICAL CHARACTERISTICS
ITEM SPECIFICATION
Operating Tensile Strength (Refer to IEC 60794-1-
3000 N
E1)
Crush Strength (Refer to IEC 60794-1-E3) 4500 N/ 100 mm
Impact Strength (Refer to IEC 60794-1-E4) 12 Nm
Kink Strength Radius (Refer to IEC 60794-1-2-E10) 5 x Cable Outside Diameter
Minimum Bending Radius (Refer to IEC 60794-1-
10 x Cable Outside Diameter
E11)
Torsion (Refer to IEC 60794-1-E7) 30 twists, 2 direction @ 180˚, Load 250N
Water Ingression Resistance (Refer to IEC 60794- Passed with 1-m cable sample, 24 hours,
1-F5B) 1-m water column height pressure
Operating & Storage Temperature Up to 70° C
CCSI Standard FTTH Aerial Figure-8 Optical Fiber
Cables
Technical Specification
GENERAL
The cable is applicable for short span overhead outdoor with span distance up to 60 meters for last mile
cable. The cable is also applicable for indoor and outdoor areas.
REFERENCE STANDARDS
The offered fiber optic cable complies to the ITU-T G.652.D, ITU-T G.657.A1, IEC 60794, TIA/ EIA standards.
CONSTRUCTIONS
CABLE STRUCTURE
Bending Loss Insensitive Fibers
– 2 Fibers (Blue & Orange) single mode ITU-T Rec. G.657.A1 bending loss insensitive optical fibers
Fully waterblocked cable
– Each fibers are inserted into thixotropic gel-filled coloured thermoplastic (PC-PBT) loose buffer tubes
– Water ingression protection
Central loose tube design
– Single loose tube
Anti-Rodent material
– Provides rodent bite protection
Supporting Strength Element Figure-8
– Galvanized steel messenger wire 7 x Ø0.4 mm as aerial cable holder
Low Smoke Zero Halogen Flame Retardant (LSZH FR) jacket
– Black UV resistant Low Smoke Zero Halogen Flame Retardant (LSZH FR) sheath as outer protection
– Reduces the amount of toxic and corrosive fume emission
– Other sheathing are available upon request
PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER
Reference Standard ITU-T G.652.D ITU-T G.657.A1
Bending-Loss Insensitive
Type Single Mode
Single Mode
Wavelength (nm) 1310 / 1550 1310 / 1550
Attenuation on Finished Cables
0.35 / 0.20 0.35 / 0.20
(dB/km)
Typical Attenuation (dB/km) 0.35 / 0.19 0.35 / 0.19
Mode Field Diameter (µm) 9.2 ± 0.4 / 10.4 ± 0.5 9.2 ± 0.4 / 10.4 ± 0.5
CABLE PARAMETERS
ITEM SPECIFICATION
Fiber Quantity 2
Loose Tube Quantity 1
Cable Diameter (Nominal) 3.0 mm
Cable
Cable Height (Nominal) 5.7 mm
Dimension
Cable Weight (Nominal) 22 kg/km
MECHANICAL CHARACTERISTICS
ITEM SPECIFICATION
Operating Tensile Strength (Refer to IEC
160 N
60794-1-E1)
Crush Strength (Refer to IEC 60794-1-E3) 1200 N/ 250 mm
Impact Strength Radius (Refer to IEC
3 Nm
60794-1-E4)
Minimum Bending Radius (Refer to IEC
15 x Cable Outside Diameter
60794-1-E11)
Torsion (Refer to IEC 60794-1-E7) 1 meter, 300 twists
Water Ingression Resistance (Refer to IEC Passed with 1-m cable sample, 24 hours,
60794-1-F5B) 1-m water column height pressure
Operating & Storage Temperature Up to 70° C
CCSI Standard FTTH Optical Fiber Cables
Technical Specification
GENERAL
The cable is applicable for short span overhead outdoor with span distance up to 60 meters for last mile
cable. The cable is also applicable for indoor and outdoor areas.
REFERENCE STANDARDS
The offered fiber optic cable complies to the ITU-T G.652.D, ITU-T G.657.A1, IEC 60794, TIA/ EIA standards.
CONSTRUCTIONS
CABLE STRUCTURE
Bending Loss Insensitive Fibers
– 2 Fibers (Blue & Orange) single mode ITU-T Rec. G.657.A1 bending loss insensitive optical fibers
Non-Metallic anti-buckling strength element
– GRP/FRP Ø 0.4 mm x 2
– Protect the optical fibers from any excessive elongation and tensile loads that occur during installation and
operation
Anti-Rodent material
– Provides rodent bite protection
Supporting Strength Element Figure-8
– Galvanized steel messenger wire rod 1 x Ø1.2 mm as aerial cable holder
Low Smoke Zero Halogen Flame Retardant (LSZH FR) jacket
– Black UV resistant Low Smoke Zero Halogen Flame Retardant (LSZH FR) sheath as outer protection
– The thermoplastic sheath does not promote the growth of fungus and be free of pits, splits and blisters
– Reduces the amount of toxic and corrosive fume emission
– Other sheathing are available upon request
PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER
Reference Standard ITU-T G.652.D ITU-T G.657.A1
Bending-Loss Insensitive
Type Single Mode
Single Mode
Wavelength (nm) 1310 / 1550 1310 / 1550
Attenuation on Finished Cables
0.35 / 0.20 0.35 / 0.20
(dB/km)
Typical Attenuation (dB/km) 0.35 / 0.19 0.35 / 0.19
Mode Field Diameter (µm) 9.2 ± 0.4 / 10.4 ± 0.5 9.2 ± 0.4 / 10.4 ± 0.5
CABLE PARAMETERS
ITEM SPECIFICATION
Fiber Quantity 2
Height (Nominal) 5.0 mm
Cable
Width (Nominal) 2.0 mm
Dimension
Weight (Nominal) 20 kg/km
MECHANICAL CHARACTERISTICS
ITEM SPECIFICATION
Operating Tensile Strength (Refer to IEC
130 N
60794-1-E1)
Crush Strength (Refer to IEC 60794-1-E3) 1200 N/ 250 mm
Impact Strength Radius (Refer to IEC 60794-
3 Nm
1-E4)
Minimum Bending Radius (Refer to IEC
15 x Cable Outside Diameter
60794-1-E11)
Torsion (Refer to IEC 60794-1-E7) 1 meter, 30 cpm,10 minutes
Water Ingression Resistance (Refer to IEC Passed with 1-m cable sample, 24 hours,
60794-1-F5B) 1-m water column height pressure
Operating & Storage Temperature Up to 70° C
Telkom Standard Duct Optical Fiber Cables
Technical Specification
GENERAL
The cable is for outdoor, underground inside HDPE ducts. The installation may use air-assisted (air-blown)
method, water pressure-floating or manual pulling.
REFERENCE STANDARDS
The offered fiber optic cable complies to the the ITU-T G.652.D, ITU-T G.655.C, ITU-T G.655.D, ITU-T
G.657.A1, IEC 60794-3, STEL K-015-2013, TIA/ EIA standards.
CONSTRUCTIONS
CABLE STRUCTURE
Fully waterblocked cable
– Each fibers are inserted into thixotropic gel-filled coloured dual-layer thermoplastic (PC-PBT) loose buffer
tubes
– Water ingression protection is applied using swellable compound and tape
Steel wire central strength member
– Steel wire central strength element as depth tracer
SZ-stranded
– Isolates fibers from installation and environmental rigors
– The loose buffer tube and fillers are SZ-stranded around FRP and bound with polyester yarns
Double Polymer Coated Aluminium Tape
– Aluminium tape as a mositure barrier
High Density Polyethylene (HDPE) jacket
– Black UV resistant High Density Polyethylene (HDPE) jacket as outer protection
– Good abrasion & scratch resistance
– Excellent weathering and UV resistance
PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER :
Reference Standard ITU-T G.652.D ITU-T G.655.C ITU-T G.655.D ITU-T G.657.A1
Non-Zero Non-Zero
Bending Loss
Dispersion Shifted Dispersion
Type Single Mode Insensitive Single
(NZDSF) Single Shifted (NZDSF)
Mode
Mode Single Mode
Wavelength (nm) 1310 / 1550 1550 / 1625 1550 / 1625 1310 / 1550
Attenuation on
Finished Cables 0.35 / 0.215 0.215 / 0.30 0.210 / 0.35 0.35 / 0.20
(dB/km)
Typical Attenuation
0.35 / 0.215 0.215 / 0.30 0.210 / 0.35 0.35 / 0.19
(dB/km)
Mode Field Diameter 9.2 ± 0.4 at 1310 9.6 ± 0.4 at 1550 9.6 ± 0.4 at 1550 9.2 ± 0.4 at 1310
(µm) nm nm nm nm
CABLE PARAMETERS :
ITEM SPECIFICATION
240 –
Fiber Quantity 4 – 36 24 – 72 60 – 96 120 – 144 120 – 216 288 – 312
264
Maximum Fibers per
6 12 12 12 12 12 12
Tube
Loose Tube Quantity 5 6 8 12 18 22 26
Number of Active Tubes 1 – 6 2–6 5–8 10 – 12 10 – 18 20 – 22 24 – 26
Cable
Cable
Diameter 11.5 mm 12.5 mm 14.0 mm 17.5 mm 18.0 mm 19.5 mm 21.0 mm
Dimension
(Nominal)
Cable Weight 110 130 165 245 255 295 335
(Nominal) kg/km kg/km kg/km kg/km kg/km kg/km kg/km
MECHANICAL CHARACTERISTICS :
ITEM SPECIFICATION
Operating Tensile Strength (Refer to IEC 60794-
2900 N
1-E1)
Crush Strength (Refer to IEC 60794-1-E3) 2200 N/ 100 mm
Impact Strength (Refer to IEC 60794-1-E4) 12 Nm
Kink Strength (Refer to IEC 60794-1-2-E10) 10 x Cable Outside Diameter
Minimum Bending Radius (Refer to IEC 60794-1-
15 x Cable Outside Diameter
E11)
Torsion (Refer to IEC 60794-1-E7) 30 cpm, 10 minutes, 2 direction @ 180˚
Water Ingression Resistance (Refer to IEC 60794- Passed with 1-m cable sample, 24 hours,
1-F5B) 1-m water column height pressure
Operating & Storage Temperature Up to 70° C
CCSI Standard Duct Non Metallic Optical Fiber Cables
Technical Specification
GENERAL
The cable is for outdoor, underground inside HDPE ducts. The installation may use air-assisted (air-blown)
method, water pressure-floating or manual pulling.
REFERENCE STANDARDS
The offered fiber optic cable complies to the the ITU-T G.652.D, ITU-T G.654.B, ITU-T G.654.C, ITU-T G.655.C,
ITU-T G.655.D, ITU-T G.657.A1, IEC 60794-3, TIA/ EIA standards. Fiber type is optional, following to the
customer request.
CONSTRUCTIONS
CABLE STRUCTURE
Fully waterblocked cable
– Each fibers are inserted into thixotropic gel-filled coloured dual-layer thermoplastic (PC-PBT) loose buffer
tubes
– Water ingression protection is applied using swellable compound and tape
Dielectric central strength member
– Requires no grounding
– More flexible
– Glass reinforced plastic (GRP/FRP) non-metallic, anti buckling central strength element
SZ-stranded
– Isolates fibers from installation and environmental rigors
– The loose buffer tube and fillers are SZ-stranded around FRP and bound with polyester yarns
High Density Polyethylene (HDPE) jacket
– Black UV resistant High Density Polyethylene (HDPE) jacket as outer protection
– Good abrasion & scratch resistance
– Excellent weathering and UV resistance
PARAMETERS
FIBER PARAMETERS OF SINGLE MODE OPTICAL FIBER :
ITU-T ITU-T G.655.C ITU-T
Reference Standard ITU-T G.652.D ITU-T G.654.C
G.654.B & 655.D G.657.A1
Non-Zero
Cut-Off Bending-Loss
Cut-Off Shifted Dispersion
Type Single Mode Shifted Insensitive
Single Mode Shifted (NZDSF)
Single Mode Single Mode
Single Mode
Wavelength (nm) 1310 / 1550 1550 1550 1550 / 1625 1310 / 1550
Attenuation on
Finished Cables 0.35 / 0.20 0.180 0.180 0.215 / 0.35 0.35 / 0.20
(dB/km)
Typical Attenuation
0.35 / 0.19 0.175 0.175 0.210 / 0.35 0.35 / 0.19
(dB/km)
Mode Field Diameter 9.2 ± 0.4 11.9 ± 0.5 9.9 ± 0.5 9.6 ± 0.4 9.2 ± 0.4
(µm) at 1310 nm at 1550 nm at 1550 nm at 1550 nm at 1550 nm
CABLE PARAMETERS :
ITEM SPECIFICATION
156 –
Fiber Quantity 4 – 30 12 – 60 72 84 – 96 108 – 144 228 – 312
216
Maximum Fibers per
6 12 12 12 12 12 12
Tube
Loose Tube Quantity 5 5 6 8 12 18 26
Number of Active Tubes 1 – 5 1–5 6 7–8 9 – 12 13 – 18 19 – 26
Cable
Diameter 9.0 mm 9.5 mm 10.0 mm 11.5 mm 14.0 mm 14.5 mm 17.5 mm
Cable
(Nominal)
Dimension
Cable Weight 100 130 160 230
60 kg/km 65 kg/km 80 kg/km
(Nominal) kg/km kg/km kg/km kg/km
MECHANICAL CHARACTERISTICS :
ITEM SPECIFICATION
Operating Tensile Strength (Refer to IEC 60794-
2900 N
1-E1)
Crush Strength (Refer to IEC 60794-1-E3) 2500 N/ 100 mm
Impact Strength (Refer to IEC 60794-1-E4) 12 Nm
Kink Strength (Refer to IEC 60794-1-2-E10) 5 x Cable Outside Diameter
Minimum Bending Radius (Refer to IEC 60794-1-
10 x Cable Outside Diameter
E11)
Torsion (Refer to IEC 60794-1-E7) 30 twists, 2 direction @ 180˚, Load 250N
Water Ingression Resistance (Refer to IEC 60794- Passed with 1-m cable sample, 24 hours,
1-F5B) 1-m water column height pressure
Operating & Storage Temperature Up to 70° C
lndonesia
GERTIFICATE
The Gertification Body
of PT fUV SUO Indonesia
certifies that
Eric Paulsen
General Manager
{w Komite Akreditasi Nasional
Lembaga Sertifikasi Sistem Mutu
LSSM-019-IDN
q
Page 1 of 1
o
q
e
o
N
o
:=
u)
lil;iiJri.Usl filoolfff t D Dipo Business cenrer.Jt Gatot Subroto Kav 5l b2 peramburan.Tanah Abans.Jakarta Pusat.l02E0 TuV@
F