Wall Heat Loss: Design Variables Nomenclature Units Value Noted
Wall Heat Loss: Design Variables Nomenclature Units Value Noted
Design Variables
Nomenclature Units Value Noted
Radius r m 0.08
Height h m 5.00
Wall Area A ft2 0.22
Wall Uniform Thickness L m 0.01
Inner Temperature T1 F 77.00
Outer Temperature T2 F 82.40
Thermal Resistance R value ft2 F hr /B TU 0.003 A516 Grade 70
Wall Heat Steady State Transfer Q BTU / hr -387.56
Page 1
Sheet1_2
Design Variables
Nomenclature Units Value Noted
Radius r m 0.08
Height h m 7.00
Wall Area A ft2 0.31
Wall Uniform Thickness L m 0.01
Inner Temperature T1 F 71.60
Outer Temperature T2 F 95.00
Thermal Resistance R value ft2 F hr /B TU 0.003 CS API 5 L Gr.B
Wall Heat Steady State Transfer Q BTU / hr -2351.21
Steam Requirement
Pressure P barg 20.00
Temperature Steam T K 212.37
Temperature Reference Tref K 298.15
Latent Heat L kJ/kg 1888
Steam Requirement m kg/hr 1.31 1.25 – 1.50 kg/hr
T/hr 0.00
Page 2
Sheet1_2
Page 3