Professional Documents
Culture Documents
Formulir Technical Analysis Report: Nomor Dokumen Tanggal Efektif Revisi Halaman
Formulir Technical Analysis Report: Nomor Dokumen Tanggal Efektif Revisi Halaman
WO :
Fax : 021-29661511
To : Plant Departement Head Office TAR No. : .…/ TAR/052C/2020
Address : Jakarta Date : 1-May-21
Attn : Damanhuri
Telp : 021-75924414 Delivery Date : 1-May-21
CC : Plant HO
Model Make : Model Type : Kilometers :
HITACHI EX3600-6
Serial No. : Unit Code. : Hour meters : 48894.5 H
EX-8003
Component : Description : Trouble Date : 6-Mar-21
HYDRAULIC SYSTEM EHC VALVE
Problem/Issue :
Bucket roll in is not working
Reason of Failure :
Stuck EHC valve bucket roll in position (Power from ELU OK, Solenoid OK), we remove the EHC Solenoid, and found stuck valve,
rusty is the problem.
Suggestion and Action taken:
1. Check the oil hydraulic sample
2.
j Replace EHC Valve with the new one
Component List :
Estimasi Cost :
Parts Number Description QTY
9242460 VALVE SOLENOID 1
TOTAL
PPN 10%
Grand Total
Picture :