8FBN15 30 RM Vol 2 PDF

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

3-22

CONTACTOR PANEL ASSY

 




 




 


   

G85703018_

CN127 connector basic conditions (battery plug connected, key switch ON)
Connector No. Connector No. Conditions Standard Remarks
CN127-1 - - -
CN127-2 N1 terminal Apply the negative probe to the
Approx. 48V
(97, RY+) (N1, N1) N1 terminal to measure voltage.
CN127-3 - - -
CN127-4 - - -
CN127-5 - - -
1·2 ton series:
CN127-6 N1 terminal Apply the negative probe to the Approx. 48V
(19, VBMBSL) (N1, N1) N1 terminal to measure voltage. 3 ton series:
Approx. 80V
CN127-7 - - -
1·2 ton series:
CN127-8 N1 terminal Apply the negative probe to the Approx. 48V
(17, SOLCOM) (N1, N1) N1 terminal to measure voltage. 3 ton series:
Approx. 80V
3-23

CN128 connector basic conditions (3 ton series only) (battery plug connected, key switch ON)
Connector No. Connector No. Conditions Standard Remarks
CN128-1 - - -
CN128-2 - - -
CN128-3 N1 Apply the negative probe to the
Approx. 80V
(1, CBAT+) (N1, N1) N1 terminal to measure voltage.
CN128-4 N1 Apply the negative probe to the
Approx. 80V
(1, CBAT+) (N1, N1) N1 terminal to measure voltage.
CN128-5 N1 Apply the negative probe to the
Approx. 80V
(1, CBAT+) (N1, N1) N1 terminal to measure voltage.
CN128-6 N1 Apply the negative probe to the
Approx. 80V
(1, CBAT+) (N1, N1) N1 terminal to measure voltage.
CN128-7 - - -
Fan ON
CN128-8 N1
Apply the negative probe to the Approx. 30V
(99, VFAN) (N1, N1)
N1 terminal to measure voltage.
Fan ON
CN128-9 N1
Apply the negative probe to the Approx. 30V
(99, VFAN) (N1, N1)
N1 terminal to measure voltage.
Fan ON
CN128-10 N1
Apply the negative probe to the Approx. 30V
(99, VFAN) (N1, N1)
N1 terminal to measure voltage.
Fan ON
CN128-11 N1
Apply the negative probe to the Approx. 30V
(99, VFAN) (N1, N1)
N1 terminal to measure voltage.
CN128-12 - - -

CN136 connector basic conditions (battery plug connected, key switch OFF)
Connector No. Connector No. Conditions Standard Remarks
Battery plug disconnected, and
CN136-1 P2
the CN136 connector Approx. 0
(101, FLP) (P2, P2)
disconnected
Battery plug disconnected, and
CN136-2 P2
the CN136 connector Approx. 0
(41, B48V) (P2, P2)
disconnected
CN136-3 CN136-4 Apply the negative probe to the
Approx. 11
(1, CBAT+) (2, CBAT-) CN136-3 to measure voltage.
Battery plug disconnected, and
CN136-4 CN136-3
the CN136 connector Approx. 20
(2, CBAT-) (1, CBAT+)
disconnected
Battery plug disconnected, and
CN136-5 P3
the CN136 connector Approx. 0
(44, VBMB) (P3, P3)
disconnected
Battery plug disconnected, and
CN136-6 P3
the CN136 connector Approx. 0
(19, VBMBSL) (P3, P3)
disconnected
1·2 ton series:
CN136-7 N1 Apply the negative probe to the Approx. 48V
(42, KYSAT) (N1, N1) N1 terminal to measure voltage. 3 ton series:
Approx. 80V
1·2 ton series:
CN136-8 N1 Apply the negative probe to the Approx. 48V
(42, KYSAT) (N1, N1) N1 terminal to measure voltage. 3 ton series:
Approx. 80V
3-24

CN137 connector basic conditions (battery plug connected, key switch OFF)
Connector No. Connector No. Conditions Standard Remarks
CN137-1 CN137-2 Apply the negative probe to the
Approx. 5V
(303, CSBAT+) (305, CSBAT-) CN137-2 to measure voltage.
CN137-2
- - -
(305, CSBAT-)
Apply the negative probe to the
CN137-3 CN137-2 CN137-2 to measure voltage.
Approx. 2.5V
(304, CSBAT) (305, CSBAT-) Drive motor, pump motor, all
auxiliary machines OFF

CN142 connector basic conditions (battery plug connected, key switch OFF)
Connector No. Connector No. Conditions Standard Remarks
CN142-1 CN142-2 Battery plug disconnected, and
Approx. 20
(P3, P3) (15, RCP) CN142 disconnected
CN142-2 Battery plug disconnected, and
- -
(15, RCP) CN142 disconnected
Battery plug disconnected, and
CN142-3 - -
CN142 disconnected

CN143 connector basic conditions (battery plug connected, key switch OFF)
Connector No. Connector No. Conditions Standard Remarks
1·2 ton series:
CN143-1 N1 Apply the negative probe to the Approx. 48V
(42, KYSAT) (N1, N1) N1 terminal to measure voltage. 3 ton series:
Approx. 80V
1·2 ton series:
CN143-2 N1 Apply the negative probe to the Approx. 48V
(42, KYSAT) (N1, N1) N1 terminal to measure voltage. 3 ton series:
Approx. 80V
CN143-3 - - -
CN143-4 - - -
1·2 ton series:
CN143-5 N1 Apply the negative probe to the Approx. 48V
(15, RCP) (N1, N1) N1 terminal to measure voltage. 3 ton series:
Approx. 80V
1·2 ton series:
CN143-6 N1 Apply the negative probe to the Approx. 48V
(15, RCP) (N1, N1) N1 terminal to measure voltage. 3 ton series:
Approx. 80V

You might also like