Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PLOT LIMIT

INSIDE OUTSIDE
PLOT LIMIT

OUT SIDE

A
PLOT LIMIT
NEIGHBOUR BOUNDARY WALL

100 900
GENERAL NOTES:

100 900
· This drawing is copyright of Urban Habitat
-1.00/-1.50 M APPROX. (UH).
FOUNDATION LEVEL · It is not allowed to copy or reproduce it's
contents in any form except for the purpose
which it is intended without the UH's authority.
100 MM GUN SHOOTING CONCRETE
SURCHARGE 20 Kpa
· Do not scale this drawing only stated
dimensions are to be considered.
· Contractor to verify the detail/information
given in this drawing, any discrepancies shall

A
be brought to Engineers attention prior to
WATER PROOFING AS SPEC'D commencement of work, failure to comply with
GUN SHOTTING CONCRETE
-10.50M MAX.
the above will be contractor's liability.
EXCAVATION SIDE EXC'N LEVEL

900 MM SECANT PILES


REINFORCEMENT AS PER SPECIALIST DESIGN

PLAN DETAIL -
SCALE 1:50

900 MM SECANT PILES


REINFORCEMENT AS PER SPECIALIST DESIGN

SEC. A-A
SCALE 1:50

F 12-10-20 FINAL DESIGN SUBMISSION -

REV. DATE DESCRIPTION BY

PURPOSE OF ISSUE:

FINAL DESIGN
PROJECT:

PROPOSED 2B+G+M+2
MIXED-USE COMPLEX
-10.50M MAX.
EXCAVATION
NORTH: PLOT
NUMBER:
3680709
CLIENT:

UNI MIX INVESTMENT (L.L.C)

CONSULTANT:

ARCHITECT MARCIN GAJDA REG. NO.115525

STRUCTURAL YOOSUF SHENI REG. NO. 94380

PROJECT
NUMBER: 17-020A
DRAWING TITLE:

SHORING DETAILS

SCALE: DATE: DRAWN BY: REVISION:

1:100/200 OCT '2020 YS/KS F


PLOT LIMIT PLOT LIMIT

DWG. SIZE: DWG. NUMBER:

A1/A3 ST-502