Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 19

Deployment Guidelines Regarding Techroutes L2 Switch

For Small Cells


March 30, 2017

Document No.

This document and any data or information generated from its use, are classified, as a minimum, Reliance Internal. Distribution is
intended for Reliance authorized recipients only. The information contained in this document is subject to the terms and conditions of
the agreement or contract under which this document was supplied to the recipient's organization. None of the information contained
in this document shall be disclosed outside the recipient's own organization, unless the terms of such agreement or contract expressly
allow, or unless disclosure is required by law.

Page 1 of 19

Reliance Jio Infocomm Limited


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

Amendment Record / Control Sheet (ACS)


Details of
Rev.
Date Reason for Issue Prepared by Reviewed by Approved by Amendments /
No.
Revisions

30-03- Nikesh Surve Francis Santana


00 Anil M Patil
2017 Anamika Sharma

Confidential | Reliance Jio Infocomm Limited | 2


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

INDEX

1 Introduction of Techroutes L2 Switch for Small Cell


connectivity.....................................................................................................................4
2 Front View of TR CES 2708F-UP L2 Switch........................................................4
3 Interface Types of TR CES 2708F-UP L2 Switch..............................................4
3.1 Management Interface…......................................................................................4
3.2 Factory Default………………………………………………………………………………...4
3.3 Service Interface.....................................................................................................6
4 Port Mapping for TR CES 2708F-UP.....................................................................5
5 LED Status info of TR CES 2708F-UP....................................................................6
6 Deployment Scenarios.............................................................................................6
6.1 Spur Connectivity (Indoor & Outdoor).......................................................7
6.2 Ring Connectivity (Outdoor)..........................................................................8
7 Accessories Supplied along with TR CES 2708F-UP.......................................9
8 Rack Mounting Procedure…………………………………………………………………11
9 Grounding Guidelines………………………………………………………………………..12
10 Powering – AC and DC Power Connections………………………………………13
11 SFP and Fiber Patch Cords Connectivity …………………………………………14
12 Device Login via Serial Console Port……………………………………………….15

Confidential | Reliance Jio Infocomm Limited | 3


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

1 Introduction of Techroutes L2 Switch for Small Cell


connectivity:-
This document we introduce Techroutes L2 Switch “2708F-UP” for Small cell connectivity.
2708F-UP is 8 port Switch consist Optical Ports.

2 Front View of 2708F-UP L2 Switch


The 2708F-UP is a 1U compact cartridge device with dimensions of 220 mm (Width) × 150
mm (Depth) × 44.2mm (Height). All interfaces are located on the front panel.

Confidential | Reliance Jio Infocomm Limited | 4


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

3 Interface Types of 2708F-UP L2 Switch

3.1 Management Interface:-

Interface Description Quantity


Console interface Assistant management interface, with which you can 1
(RJ 45) configure and manage the TR CES 2708F-UP initially
through the terminal software, such as the Hyper
Terminal in Windows/Secure CRT/Putty

3.2 Factory Default Button:-

Interface Description Quantity


ZTP button Push 5 second button for Restore the default 1
configuration, Once switch comes factory default and
ZTP provision is working automatically switch
configure.

3.3 Service Interface:-

1. Network interface(GigaEthernet):-

Confidential | Reliance Jio Infocomm Limited | 5


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells
Port Type - 2 x GE SFP Ports
Port Name - Giga 0/1 and Giga 0/2
Application - Network Ports for Backhaul connectivity.

2. User Network Interface(GigaEthernet):-

Port Type - 6 x GE SFP Ports


Port Name – Giga 0/3 to Giga 0/8
Application – Service downlink interface for Small Cells.

4 Port Mapping for 2708F-Up:-

Port type Port Access ID Purpose


Optical Giga0/1 Uplink
Optical Giga0/2 Uplink
Optical Giga0/3 Small Cell-1
Optical Giga0/4 Small Cell-2
Gi
Optical Small Cell-3
ga0/5
Optical Giga0/6 Small Cell-4
Optical Giga0/7 Small Cell-5/Enterprise
Optical Giga0/8 Small Cell-6/Utility/RJIL-IT

Confidential | Reliance Jio Infocomm Limited | 6


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

5 LED Status info of 2708F-UP:-


Interface LED Status Description
Power supply LED
-Green: the power supply is normal.
- PWR Green
-Off: there is no power supply or the power supply is
abnormal.

- SYS Green -Flickering green every 1s in normal operation.


- If the indicator flickers, the data is being forwarded.
Interface working status LED
-Green: the optical interface is connected properly.
Green
LNK/A - Flickering green: the optical interface is
Giga (SFP) /
CT sending/receiving data.
Orange
-Off: the optical interface is disconnected or connected
improperly.

LNK/A - Press ZTP button the ZTP LED will glow green
ZTP Green
CT for 3 seconds

- SD card slot
SD card slot - -

Confidential | Reliance Jio Infocomm Limited | 7


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

6 Deployment Scenarios:-

6.1 Spur Connectivity (Indoor & Outdoor)

Confidential | Reliance Jio Infocomm Limited | 8


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

6.2 Ring Connectivity (Outdoor)

Confidential | Reliance Jio Infocomm Limited | 9


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

7 Accessories Supplied along with 2708F-UP


No Item Image Remarks

Mounting Bracket
1  
(1 Set)

2 Screw (4 Nos.)  

Console cable
3 (Navy Blue)  
(1 No.)

DC Connector
4  
(1 No)

5 Grounding Cable  

Confidential | Reliance Jio Infocomm Limited | 10


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

8 Rack Mounting Procedure 2708F-UP

Rack Mounting Procedure

1. Install Mounting brackets on both sides of device with proper screws which are provided.

2. Install the device in the Rack with Floating nuts

Confidential | Reliance Jio Infocomm Limited | 11


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

9 Grounding Guidelines:-

Confidential | Reliance Jio Infocomm Limited | 12


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

10 Powering – AC and DC Power Connections:-

L2 Switch can be powered by both AC and DC power supply at a time one will work.

Insert AC or DC Power Card on the Device – Single slot are compatible for both AC and DC
cards.

Confidential | Reliance Jio Infocomm Limited | 13


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

11 SFP and Fiber Patch Cords Connectivity Guideline:-

Confidential | Reliance Jio Infocomm Limited | 14


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

a. Connecting Console cable

12 Device Login via Serial Console Port:-


1. Connect one end of Console cable to the L2 Switch console port (RJ45 Port) and other end
to the Laptop (COM Port) – Console cable is supplied along with the Switch.
2. Right Click on My Computer and select the properties option.
3. Select Device Manager
4. Select the Ports and cross check on which COM port the L2 Switch is get connected.

Confidential | Reliance Jio Infocomm Limited | 15


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

Confidential | Reliance Jio Infocomm Limited | 16


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

5. Open Secure CRT/Putty, Hyper Terminal, Xshell Application.

6. In case of Secure CRT – Go to Quick Connect

7. Select the Protocol Serial

Confidential | Reliance Jio Infocomm Limited | 17


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

8. Set the Serial Parameter such as Port,Baud Rate (9600) and Click on Connect

Confidential | Reliance Jio Infocomm Limited | 18


Deployment Guidelines Regarding Techroutes L2 Switch For Small Cells

9. Press Enter and enter the Username and password as admin to login into Device

13 Escalation Matrix:-
Technical Team

Level 1 Rahul Todkar Rahul.todakr@ril.com +91 7498444544


Level 2 Harshad Marathe harshad.marathe@ril.com +91 9699766645
Dinesh Rastogi Dinesh.rastogi@techroutes.com +91 9899663276
Level 3 Sanjay Makhija sanjaym@techroutes.com +91 9699466645
Level 4 AnilRaj araj@techroutes.com +91 9350990860

14 Fault & RMA Generation:-


TAC Team
Customer Support Executive – support@techroutes.com
Mobile - +91 7498444544 / 9699766645

Confidential | Reliance Jio Infocomm Limited | 19