TEST REPORT
No.: 8881/03
TEST RESULTS: The composite long rod insulator passed withstand salt fog
test according to IEC 60507, clause 12 for the highest possible
withstand salinity 224 kg/m3.
COPIES: 6 PAGES: 5
Test report is confidential and must not be passed over or transferred to any third party without written approval
of the customer. Test results relate only to the tests given in presented report and do not substitute any other
documents. The report shall not be reproduced except in full without written approval of the testing laboratory.
TEST OBJECT
DATE OF DELIVERY
2003-09-30
SCHEDULE OF TEST
1. Preconditioning process according to agreed method between
customer and test laboratory
2. Withstand salt fog test IEC 60507, clause 11
TEST PROCEDURE
1. Preconditioning process
Preconditioning process was performed according to agreed method between customer and test
laboratory. The test voltage 156 kV was applied on the composite long rod insulator for three
hours without interruption at the salinity 80 kg/m3 before withstand salt fog test.
Testing and measuring equipments for test No.1 and test No.2:
- test transformer TuR Dresden 200 kV, 2000 kVA,
- regulating transformer TuR Dresden 6/0-6,3 kV, 3200 kVA,
- capacitive divider TuR Dresden, type MCF 600, serial No. 863705,
- universal voltmeter TuR Dresden, type MUT 7, serial No. 872391,
- digital stop-watch Pragotron, type DTS 11, serial No. 900462.
2
Test report No.: 8881/03 EGÚ – HV LABORATORY
UNCERTAINTY OF MEASUREMENT
UNCERTAINTY
QUANTITY
k=2
TEST RESULTS
1. Preconditioning process
Table 1
1 80 156 60 No flashover
2 80 156 60 No flashover
3 80 156 60 No flashover
Table 2
No flashover occurred during a series of three consecutive tests with withstand salinity
224 kg/m3 and test voltage 243 kV. The requirements of the customer were met.
The composite long rod insulator, type CS310CC 30/100(168)5180, drawing No. 98K6479
p a s s e d withstand salt fog test according to IEC 60507, clause 12 for the highest
possible withstand salinity 224 kg/m3.
3
Test report No.: 8881/03 EGÚ – HV LABORATORY
Photo 1
Composite long rod insulator, CS310CC 30/100(168)5180
drawing No.: 98K6479,
test arrangement under the withstand salt fog test
4
Test report No.: 8881/03 EGÚ – HV LABORATORY
Fig. 1
Composite long rod insulator, CS310CC 30/100(168)5180, drawing No.: 98K6479