G/F Lighting Layout 2/F Lighting Layout: St. Agatha Homes, Tikay, Malolos, Bulacan
G/F Lighting Layout 2/F Lighting Layout: St. Agatha Homes, Tikay, Malolos, Bulacan
z z
canopy line
m m m 3S-stu
i i t t x x r r
H L L L w
y
line of balcony
m Swxy
3S-G v r r
i i
Si 02 t t 03
L k L PB
a
PB
01 Sa
PB SjkL Sr
Sm 3S-tuv o o
3S-def Sn
Sgh g g 3S-cz
j j j u u n n p
h
Sopq q
04
PB
Ss
d
f f f
d
s s
b c
d
(to second floor)
3S-cz e e e
Sab 3S-def s s
z z
a a
canopy line
THE SITE
ST. AGATHA HOMES,TIKAY, MALOLOS, BULACAN
13 11 14
LIGAS 16
canopy line
04
STA. RITA 05
PB
PUBLIC PB
MARKET
12
CAMP RESORT 19 17 PB
PB 10
R D .
PB
PB 07
18 PB
PRITIL PB DN
L E Y
ST. AGATHA
V A L
HOMES
N
A Y A
15
PB
C A G
NATURE'S SPRING
MINERAL WATER
BULACAN
UP
SAN PABLO
SAN
MIGUEL
REFERENCE POINT
BREWERY
UP
ER INC.
RIV
NG
BA
TA
FORD MALOLOS
canopy line CANOPY LINE
M A PUREGOLD
C A GUIGUINTO
R T
H U
R
H I
G H
W A
Y
FIRST BULACAN
INDUSTRIAL CITY
FUNNSIDE
VICINITY MAP 3 G/F POWER & AUXILIARY LAYOUT 4 2/F POWER & AUXILIARY LAYOUT
T A B
NINGNANGAN A N G
S P U
SHELL R R
PROFESSIONAL PROJECT OWNER SHEET CONTENT REPUBLIC ACT NO. 9266 APPROVED BY NO BY STATUS SHEET NO
REVISIONS
DEOGRACIAS C. PASCUAL. PEE PROPOSED TWO-STOREY RESIDENCE MR. & MRS. ROBIN CARLO DE VILLA DRAWINGS AND SPECIFICATIONS, DULY SIGNED AND SEALED AS INSTRUMENTS OF CHECKED BY:
FLOOR PLANS
ENGINEER OWNER ROOF PLAN
SERVICE ARE THE PROPERTIES AND DOCUMENTS OF HERNANDO G. ADVENTO
BUILDERS CORP, WHETHER THE OBJECT WHICH THEY ARE MADE IS EXECUTED OR CHECKED BY: E-01
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN CONSENT
PRC NO. 0002724 TIN 187-908-449 PROJECT LOCATION ADDRESS REFLECTED CEILING PLANS OF THE ARCHITECT OR AUTHOR OF THE SAID DOCUMENTS TO DUPLICATE OR TO CHECKED BY: PROJ. NO. REV.
PTR NO. DATE MAKE COPIES OF SAID DOCUMENT FOR USE IN THE REPETITION OF AND FOR
PLACE
BLK. 5 LOT 1 PH. 3, ST. AGATHA HOMES, TIKAY, MALOLOS, BULACAN ST. AGATHA HOMES, TIKAY, MALOLOS, BULACAN SCHEDULE OF FINISHES OTHER PROJECTS OR BUILDING, WHETHER EXECUTED PARTLY OR IN WHOLE. CHECKED BY:
LOAD SCHEDULE & COMPUTATIONS:
POWER SERVICE ENTRANCE
230V, 1Ø, 60HZ
X50
KW-H METER
(BY MERALCO) M
ECB
150AT,2P
X50
PB
150AT
2P
20AT,2P 20AT,2P
L.O. 1 2 L.O.
20AT,2P 20AT,2P
L.O. 3 4 L.O.
20AT,2P 20AT,2P
C.O. 5 6 C.O.
20AT,2P 20AT,2P
C.O. 7 8 C.O.
40AT,2P 20AT,2P
RANGE 9 10 REF.
30AT,2P 30AT,2P
WATER HEATER 11 12 WATER HEATER
30AT,2P 30AT,2P
WATER HEATER 13 14 ACU,1.0HP
30AT,2P 30AT,2P
ACU,1.0HP 15 16 ACU,1.0HP
30AT,2P 30AT,2P
ACU,2.0HP 17 18 WATER PUMP
30AT,2P 40AT,2P
LANDSCAPE 19 20 ACU, 4.0HP
20AT,2P 20AT,2P
SPARE 19 20 SPARE
GROUND
MOUNTING HEIGHT
ACU OUTLET
1.8M
LIGHT SWITCH
1.2M MAX
CONVENIENCE OUTLET
TELEPHONE SOCKET
TV AERIAL SOCKET
0.30M MIN.
FLOOR LEVEL
PROFESSIONAL PROJECT OWNER SHEET CONTENT REPUBLIC ACT NO. 9266 APPROVED BY NO BY STATUS SHEET NO
REVISIONS
DEOGRACIAS C. PASCUAL. PEE PROPOSED TWO-STOREY RESIDENCE MR. & MRS. ROBIN CARLO DE VILLA ONE LINE DIAGRAM DRAWINGS AND SPECIFICATIONS, DULY SIGNED AND SEALED AS INSTRUMENTS OF CHECKED BY:
ENGINEER OWNER
LOAD SCHEDULE & COMPUTATION SERVICE ARE THE PROPERTIES AND DOCUMENTS OF HERNANDO G. ADVENTO
BUILDERS CORP, WHETHER THE OBJECT WHICH THEY ARE MADE IS EXECUTED OR CHECKED BY: E-02
GENERAL NOTES NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN CONSENT
PRC NO. 0002724 TIN 187-908-449 PROJECT LOCATION ADDRESS OF THE ARCHITECT OR AUTHOR OF THE SAID DOCUMENTS TO DUPLICATE OR TO CHECKED BY: PROJ. NO. REV.
PTR NO. DATE WIRE & CONDUIT SCHEDULE MAKE COPIES OF SAID DOCUMENT FOR USE IN THE REPETITION OF AND FOR
BLK. 5 LOT 1 PH. 3, ST. AGATHA HOMES, TIKAY, MALOLOS, BULACAN ST. AGATHA HOMES, TIKAY, MALOLOS, BULACAN OTHER PROJECTS OR BUILDING, WHETHER EXECUTED PARTLY OR IN WHOLE. CHECKED BY:
PLACE MOUNTING HEIGHT
canopy line canopy line
second floor line
canopy line
DN
UP
REFERENCE POINT
UP
1 G/F COLD WATER LINE LAYOUT 2 2/F COLD WATER LINE LAYOUT
THE SITE
ST. AGATHA HOMES,TIKAY, MALOLOS, BULACAN
STA. RITA
PUBLIC
canopy line
MARKET
CAMP RESORT
R D .
PRITIL
L E Y
ST. AGATHA
V A L
DN
HOMES
N
A Y A
C A G
NATURE'S SPRING
MINERAL WATER
BULACAN
SAN PABLO
SAN
MIGUEL UP
BREWERY
R INC.
IVE
N GR
BA BUILDING LINE
TA
REFERENCE POINT
FORD MALOLOS
UP
FIRST BULACAN
INDUSTRIAL CITY
FUNNSIDE T A B
NINGNANGAN A N G
S P U
SHELL R R
3 G/F SANITARY & STORM DRAIN 4 2/F SANITARY & STORM DRAIN 5 ROOF STORM DRAIN LAYOUT
VICINITY MAP
PROFESSIONAL PROJECT OWNER SHEET CONTENT REPUBLIC ACT NO. 9266 APPROVED BY NO BY STATUS SHEET NO
REVISIONS
PROPOSED TWO-STOREY RESIDENCE MR. & MRS. ROBIN CARLO DE VILLA DRAWINGS AND SPECIFICATIONS, DULY SIGNED AND SEALED AS INSTRUMENTS OF CHECKED BY:
LEGENDS
OWNER VICINITY MAP
SERVICE ARE THE PROPERTIES AND DOCUMENTS OF HERNANDO G. ADVENTO
BUILDERS CORP, WHETHER THE OBJECT WHICH THEY ARE MADE IS EXECUTED OR CHECKED BY: P-01
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN CONSENT
PRC NO. TIN PROJECT LOCATION ADDRESS COLD WATER LINE LAYOUT OF THE ARCHITECT OR AUTHOR OF THE SAID DOCUMENTS TO DUPLICATE OR TO CHECKED BY: PROJ. NO. REV.
PTR NO. DATE MAKE COPIES OF SAID DOCUMENT FOR USE IN THE REPETITION OF AND FOR
PLACE
BLK. 5 LOT 1 PH. 3, ST. AGATHA HOMES, TIKAY, MALOLOS, BULACAN ST. AGATHA HOMES, TIKAY, MALOLOS, BULACAN SANITARY & STORM DRAIN LAYOUT OTHER PROJECTS OR BUILDING, WHETHER EXECUTED PARTLY OR IN WHOLE. CHECKED BY:
5
2 4
3
line DN
opy
can
line
py
ano
F
c
E opyl
ine DN
E can
LIN
OPY
CAN
D line
opy
C can
B PY
LIN
E
5 5 O
CAN
A D
4
C4
B
3 3
2 2
ine ine
o rl rl
flo INT loo INT
ond
PO
o n df EP
O
ec ec
E
ENC C
line s line s
EN
ER ER
o py REF op y REF
can can
e ve
bov abo
onya ny
bal
c lco ba
of UP of UP
MP MP
line RA line RA
F UP
UP F UP
UP
E E
line yl
ine
opy o p
can can
D D
C C
SEPTIC TANK DETAILS
B B
A A
PROFESSIONAL PROJECT OWNER SHEET CONTENT REPUBLIC ACT NO. 9266 APPROVED BY NO BY STATUS SHEET NO
REVISIONS
PROPOSED TWO-STOREY RESIDENCE MR. & MRS. ROBIN CARLO DE VILLA DRAWINGS AND SPECIFICATIONS, DULY SIGNED AND SEALED AS INSTRUMENTS OF CHECKED BY:
CATCH BASIN & AREA DRAIN DETAILS
OWNER SEPTIC TANK DETAILS
SERVICE ARE THE PROPERTIES AND DOCUMENTS OF HERNANDO G. ADVENTO
BUILDERS CORP, WHETHER THE OBJECT WHICH THEY ARE MADE IS EXECUTED OR CHECKED BY: P-02
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN CONSENT
PRC NO. TIN PROJECT LOCATION ADDRESS COLD WATER LINE ISOMETRIC LAYOUT OF THE ARCHITECT OR AUTHOR OF THE SAID DOCUMENTS TO DUPLICATE OR TO CHECKED BY: PROJ. NO. REV.
PTR NO. DATE MAKE COPIES OF SAID DOCUMENT FOR USE IN THE REPETITION OF AND FOR
PLACE