Tubular Inspection Sheet - 2021-001 Part 3

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Client: SCIENTIFIC DRILLING INTERNATIONAL

TUBULAR INSPECTION SHEET Inspection Sheet No.: 2021-001 Approved JO No.:


Delivery Ref: MRR Received by: JOEL ANDRES MRR No.: 21-001
Date: JANUARY 7, 2021 Date Received: JANUARY 5, 2021 Page No.: 3 OF 4

Box Pin REMARKS


Item Qty. Description Serial No.
Connection Relief Features Tool Joint O.D. Connection Relief Features Tool Joint O.D. CENTER THREAD BOX PIN

CORROSION CAN BE SEEN


CORROSION CAN BE SEEN ON
12-1/8" INTEGRAL BLADE STABILIZER STRING ON THREAD AND SEAL
3 1 20-119 6-5/8" REG BB 8" 6-5/8" REG SRG 8" N/A THREAD AND SEAL SURFACE.
(OAL: 2310mm) SURFACE. THREADS HAS
PITTED THREADS
PITTINGS.

SCOPE OF WORK: REPAIR CRACK ON BLADE BASE AND REWELD. AFTER REWELD, CONDUCT NDT INSPECTION ON WELDED PARTS.

Corrosion on Seal
Surface Severe corrosion on thread surface

The base of the blade


has already been
grinded.

Crack on Blade base

Corrosion on Seal
Surface

TOOLS URGENTLY NEEDS TO BE DONE IMMEDIATELY PRIOR TO WOR REMARKS Inspected By Reviewed By Approved By
ITEM NOS. : ALL SELECTED ITEMS ONLY (REFER BELOW)

CONFIRMED BY :
WITH THREAD PROTECTOR
PRINT NAME OVER SIGNATURE ALDRIN HERNANDEZ MARJUN ALOLOR JAYSON AGUSTINO
RE-FAX WITH THIS SECTION COMPLETELY FILLED-UP QA/QC Engineer QA/QC Supervisor SCO Manager
FM-WI-QAD-01-01 Rev. 1

You might also like