>9F ;GAD MFALK >9F ;GADK ;9L9DG?

M=

>DGGJ KL9F<AF?

;GF;=9D=< ;=ADAF?

>D=PA LQH=

ooo&\Yacaf&]m
9 : GM L <9ACAF
Daikin has a worldwide reputation based on over
80 years’ experience in the successful manufacture of
high quality air conditioning equipment for industrial,
commercial and residential use.

Daikin Europe N.V.

Fan Coil Units are a highly efficient means of turning a water chiller or hot water boiler into an efficient, quiet air
conditioning system. These units are an effective solution to provide a comfortable environment for both commercial
and residential applications.

DAIKIN offers a wide range of Fan Coil Units for both concealed and exposed applications. 3 models are available in
flexible application. The only moving part in the units is the fan, which making them ideal for use in offices, hotels and
at home. The goal is to obtain the right solution, both technically and aesthetically.

>d]paZd] kgdmlagfk
Fan Coil Units in combination with chillers and or boilers can be used to provide a broad range of solutions that
can be tailored to local conditions such as climate, primary fuel market or building insulation. In warmer climates
or when a building is well insulated, Fan Coil Units with only a chiller (2-pipe system) can handle both cooling and
heating. Here the chiller is capable of operating in cooling as well as heat pump mode. In more severe climates, a
(* boiler can be added (4-pipe system) allowing optimal cooling in the summer using the chiller, and efficient heating
in the winter via the boiler. Adding to the flexibility when designing applied systems applications, is the ability to
equip the Fan Coil Unit with an optional electric heater. In situations where it is not economical to operate a
boiler and where a chiller in heat pump mode is also not desirable, the electric heater can quickly heat up a room.

The combinations made possible by the Daikin range of Fan Coil Units allow a chiller-based solution to be optimally
designed for just about any application and price range.

L9 : D = G > ;G F L =F L K

FWV 04

FWL 05

FWM 06

FWB 07

FWD 08

Control 09

Accessories 10
H JG <M ;L HGJL>GD AG

Reference 1 2 3 4 5 6 7 8 9 10 11 12 16 18 20 22kW

cooling 01 02 03 04 06 08 10

2-pipe
heating 01 02 03 04 06 08 10
FWV

cooling 01 02 03 04 06 08 10
4-pipe
heating 01 02 03 04 06 08 10

cooling 01 02 03 04 06 08 10 (+
2-pipe
heating 01 02 03 04 06 08 10
FWL

cooling 01 02 03 0406 08 10

4-pipe
heating 01 02 03 04 06 08 10

cooling 01 02 03 04 06 08 10

2-pipe
heating 01 02 03 04 06 08 10
FWM

cooling 01 02 03 04 06 08 10

4-pipe
heating 01 02 03 04 06 08 10

cooling 02 03 04 05 06 07 08 09 10
2-pipe
heating 02 03 04 05 06 07 08 09 10
FWB

cooling 02 03 04 05 06 07 08 09 10 02
4-pipe 02 05 08
heating 03
04
06
07
09
10

cooling 04 06 08 10 12 16 18

2-pipe
heating 04 06 08 10 12 16 18
FWD

cooling 04 06 08 10 12 16 18

4-pipe 08 16
heating 04 06
10
12
18

-EASURINGCONDITIONSATNOMINALAIRFLOWAND%30 #//,).'sAIRTEMPERATUREENTERINGTHEUNITª#ª#sWATERTEMPERATUREENTERINGTHEUNITª#sLEAVINGTHEUNITª#
(%!4).'sROOMAIRTEMPERATUREª#sFORPIPEUNITSWATERTEMPERATUREENTERINGª# WATERFLOWRATESAMEASFORTHECOOLINGTESTsFORPIPEUNITSWATERTEMPERATUREENTERING
ª# WATERTEMPERATURELEAVINGª#.
=;>O=J. =;>O=:.

>ON(*;9L

› Quick fixing system for wall mounting


› Pre-assembled 3-way/4-port ON/OFF valves are available
› Valve packages are insulated, no extra drain pan required
› Valve packages contain balancing valves
and sensor pocket
› Fast-on connections for electrical options
› Quick removal of washable filter
› Electrical heater : no relay up to 2kW capacity
› Electrical heater : equipped with two overheat
cut-out thermostats

(,
+
> ON ^dggj klYf\af_ mfal

FWV01-10C* 2-pipe (*=TN or TV) 4-pipe (*=FN or FV)


             
0OWERINPUT W            
4OTALCAPACITY kW              
#OOLINGCAPACITY
3ENSIBLECAPACITY kW              
#APACITY
(EATINGCAPACITY PIPE kW       
(EATINGCAPACITY PIPE kW       
 X
Dimensions H xW x D mm XX XX XX XX XX XX
XX X
-ACHINEWEIGHT kg            
3OUNDLEVEL 3OUNDPOWER dBA              
Cooling kPa            
7ATERPRESSUREDROP
Heating kPa            
Fan Air flow rate M¨H              
Water connections 3TDHEATEXCHANGER INCH    
2EQUIREDPOWERSUPPLY 6F(Z 
Cooling LH                  
Water flow
Heating LH                
Coil 7ATERVOLUME HEATING l     
Maximum absorbed current W              


4. PIPE WITHOUTVALVES 46 PIPE WITH/./&& WAYVALVES &. PIPE WITHOUTVALVES &6 PIPE WITH/./&& WAYVALVES
=;>O=J. =;>O=:. >OD(+;

>OD(+;

› Quick fixing system for wall/ceiling mounting


› Pre-assembled 3-way/4-port ON/OFF valves are available
› Valve packages are insulated, no extra drain pan required
› Valve packages contain balancing valves and sensor pocket
› Fast-on connections for electrical options
› Quick removal of washable filter
› Electrical heater : no relay up to 2kW capacity
› Electrical heater : equipped with two overheat cut-out
thermostats

^d]pa lqh] mfal >O D (-


, ,

FWL01-10C* 2-pipe (*=TN or TV) 4-pipe (*=FN or FV)


             
0OWERINPUT W            
4OTALCAPACITY kW              
#OOLINGCAPACITY
3ENSIBLECAPACITY kW              
#APACITY
(EATINGCAPACITY PIPE kW       
(EATINGCAPACITY PIPE kW       
X X
Dimensions H xW x D mm XX XX XX XX XX XX
X X
-ACHINEWEIGHT kg            
3OUNDLEVEL 3OUNDPOWER dBA              
Cooling kPa            
7ATERPRESSUREDROP
Heating kPa            
Fan Air flow rate M¨H              
Water connections 3TDHEATEXCHANGER INCH    
2EQUIREDPOWERSUPPLY 6F(Z 
Cooling LH                  
Water flow
Heating LH                
Coil 7ATERVOLUME HEATING l     
Maximum absorbed current W              

4. PIPE WITHOUTVALVES 46 PIPE WITH/./&& WAYVALVES &. PIPE WITHOUTVALVES &6 PIPE WITH/./&& WAYVALVES
=;>O=J. >OE();

>OE();

› Quick fixing system for wall/ceiling mounting


› Pre-assembled 3-way/4-port ON/OFF valves are available
› Valve packages are insulated, no extra drain pan required
› Valve packages contain balancing valves
and sensor pocket
› Fast-on connections for electrical options
Quick removal of washable filter
› Electrical heater : no relay up to 2kW capacity
› Electrical heater : equipped with two overheat
cut-out thermostats

(.
> OE ^d]pa lqh] mfal

FWM01-10C* 2-pipe (*=TN or TV) 4-pipe (*=FN or FV)


01 02 03 04 06 08 10 01 02 03 04 06 08 10
Power input W 37 53 56 98 182 244 37 53 56 98 182 244
Total capacity kW 1.54 2.09 2.93 4.33 4.77 6.71 8.02 1.46 1.90 2.87 4.33 4.67 6.64 7.88
Cooling capacity
Sensible capacity kW 1.20 1.51 2.11 3.15 3.65 4.91 5.96 1.14 1.51 2.07 3.15 3.57 4.85 5.85
Capacity
Heating capacity (2-pipe) kW 2.14 2.57 3.81 5.63 6.36 7.83 10.03 -
Heating capacity (4-pipe) kW - 1.90 2.10 3.08 5.05 5.30 7.91 9.30
Dimensions H xW x D mm 535x584x224 535x794x224 535x1004x224 535x1214x249 535x584x224 535x794x224 535x1004x224 535x1214x249
Machine weight kg 14 15 19 23 32 15 16 20 25 34
Sound level Sound power dBA 45 50 47 52 56 61 66 45 50 47 52 56 61 66
Cooling kPa 13 11 12 14 12 19 13 11 12 14 12 19
Water pressure drop
Heating kPa 9 11 9 10 9 16 7 8 5 10 8 9
Fan Air flow rate m³/h 319 344 442 706 785 1011 1393 307 327 431 690 763 998 1362
Water connections Std. heat exchanger inch 1/2 3/4 1/2 3/4
Required power supply V / f / Hz 230/1/50
Cooling l/h 265 359 504 745 820 1,154 1,343 251 327 494 745 803 1,142 1,355
Water flow
Heating l/h 265 359 504 745 820 1,154 1,343 196 182 286 396 465 694 816
Coil Water volume heating l - 0.5 0.7 1 1.4 2.1
Maximum absorbed current W 0.17 0.24 0.25 0.44 0.43 0.80 1.12 0.17 0.24 0.25 0.44 0.43 0.80 1.12

* : TN (2-pipe, without valves) - TV (2-pipe, with ON/OFF 3-way valves) - FN (4-pipe, without valves) - FV (4-pipe, with ON/OFF 3-way valves)
ECFWER6
FWB04AAT

› Height of the units only 240mm for all the sizes


› 3, 4 or 6 stage row cooling coil
› Drain pan to collect the condensate from:
heat exchanger and regulating valves
› 7-speed electrical motors
(with thermal protection on windings)
› All 7 speeds pre-wired in the factory in
the terminal block of the switch box
› Standard air filter : removable from the bottom

con cea le d ceiling unit FWB 07

FWB02-10AT 2-pipe
02 03 04 05 06 07 08 09 10
Power input W 106 192 294
Total capacity kW 2.61 3.14 3.49 5.08 5.45 6.47 7.57 8.67 10.34
Cooling capacity
Sensible capacity kW 1.88 2.16 2.34 3.60 3.87 4.40 5.23 5.96 6.90
Capacity
Heating capacity (2-pipe) kW 5.47 6.01 6.47 10.31 11.39 12.28 15.05 16.85 18.78
Heating capacity (4-pipe)* kW 3.14 5.99 12.80
Dimensions H xW x D mm 239x1039x609 239x1389x609 239x1739x609
Machine weight kg 23 24 26 31 33 35 43 45 48
Sound level Sound power dBA 58 60 69
Cooling kPa 8 14 11 15 8 14 21 26
Water pressure drop
Heating kPa 7 10 8 12 7 10 16 15 18
Air flow rateww m³/h 400 800 1200
Fan
Available pressure Pa 71 65 59
Water connections Std. heat exchanger inch 3/4
Required power supply V / f / Hz 230/1/50
Cooling l/h 448 539 598 873 936 1,111 1,299 1,488 1,774
Water flow
Heating l/h 275 526 1,123
Maximum absorbed current W 0.51 0.94 1.28

* : 4-pipe = 2-pipe + option Additional heat exchanger


=;>O=J.

>O<(,9

>O<(,9

› Quick fixing system for wall/ceiling mounting


› Straight duct connector is mounted
to discharge side
› Standard air filter : removable from the bottom

(0
> O< ^d]pa lqh] mfal

FWD04-18A* 2-pipe (*=T) 4-pipe (*F)


04 06 08 10 012 016 018 04 06 08 10 012 016 018
Power input W 234 349 443 714 1197 234 349 443 714 1197
Total capacity kW 3.90 6.20 7.80 8.82 11.90 16.40 18.30 3.90 6.20 7.80 8.82 11.90 16.40 18.30
Cooling capacity
Sensible capacity kW 3.08 4.65 6.52 7.16 9.36 12.80 14.10 3.08 4.65 6.52 7.16 9.36 12.80 14.10
Capacity
Heating capacity (2-pipe) kW 4.49 6.62 9.21 15.86 21.15 -
Heating capacity (4-pipe) kW - 4.05 7.71 9.43 10.79 14.45 19.81 21.92

280 280 280 280 352 280 280 280 352 352
Dimensions H xW x D mm x754 x964 x1174 x1174 x1384 x754x x964 x1174 x1174 x1384
x559 x559 x559 x559 x718 559 x559 x559 x718 x718

Machine weight kg 35 43 50 52 71 83 86 33 41 47 49 65 77 80
Sound level Sound power dBA 66 69 72 74 78 66 69 72 74 78
Cooling kPa 17 24 16 26 34 45 17 24 16 26 34 45
Water pressure drop
Heating kPa 9 15 13 12 16 14 20 13 21 28 37
Air flow rate m³/h 800 1250 1600 2200 3000 800 1250 1600 2200 3000
Fan
Available pressure Pa 63 53 63 59 92 138 128 66 58 68 64 97 145 134
Water connections Std. heat exchanger inch 3/4 1 3/4 1
Required power supply V / f / Hz 230/1/50
Cooling l/h 674 1,064 1,339 1,514 2,056 2,833 3,14 674 1,064 1,339 1,514 2,056 2,833 3,140
Water flow
Heating l/h 674 1,064 1,339 1,514 2,056 2,833 3,140 349 581 808 1,392 1,856

* : T(2-pipe) - F(4-pipe)
CONTROL
The fan coil units can be operated by different controllers according to the model.

Electronic built-in controller: ECFWEB6 Master / Slave interface: EPIMSA6


& Electronic remote controller: ECFWER6 › Available as an additional interface,
› Operating mode: automatic or at fixed which is required for units with a current
speed greater than 1.12A.
› Setting: to turn the fan coil unit ON / OFF › Optional for remote control of up to
› Controlling the electric heating 4 fan coil units
› Cooling / heating selector › Up to 3 Master / Slave interfaces can be
› Thermostat to control the room connected in parallel, enabling control
temperature over up to 12 fan coil units.
› Operational LEDs that indicate the
current operating mode
› Voltage free contacts, allowing to switch Power interface: EPIA6
the unit ON / OFF › Available as an additional interface,
› Voltage free contacts for centralized which is required for units with a current
cooling/heating changeover greater than 1.12A.
› Water temperature probe › Required for connection of ECFWER6
› Air temperature probe to FWD12-18.
› Can be used as an alternative for
Master / Slave interface.
Electromechanical built-in controller:
ECFWMB6 09
› Fan speed selector
› Manual cooling/heating changeover.
› ON / OFF valves can also be controlled
with ECFWMB6.
9;; = KK G JA=K
Type: FWM, FWL, FWV
1 2 3 4 6 8 10 FWV FWL FWM
Description
!DDITIONALSINGLEROWHEATEXCHANGER %32(! %32(! %32(! %32(! x x x
%LECTRICHEATER %%(! %%(! %%(! %%(! %%(! x x x
 PIPE WAYVALVE %-6! %-6! %-6! x x x
 PIPE WAYVALVE %-6! %-6! %-6! x x x
&ANSTOPTHERMOSTAT 9&34! x x x
!IRINTAKEDISCHARGEGRILLE %!)$&! %!)$&! %!)$&! %!)$&! x
3UPPORTINGFEET %3&6! %3&6! x x
3UPPORTINGFEET GRILLE %3&6'! %3&6'! %3&6'! %3&6'! x
&RESHAIRINTAKE %&!! %&!! %&!! %&!! x x x
2EARPANEL %206! %206! %206! %206! x x
#ONTROLLERELECTROMECHANICAL %#&7-" x x
#ONTROLLERELECTRONIC BUILT IN %#&7%" x x
#ONTROLLERELECTRONIC REMOTE %#&7%2 x x x
-ASTERSLAVEOPTION %0)-3! x x x
6ERTICALDRAINPAN %$06! x x x
(ORIZONTALDRAINPAN %$0(! x x

)(

Type: FWB-A
2-4 5-7 8-10
Description
!DDITIONALHEATEXCHANGER %!(! %!(! %!(!
 WAYVALVEADDHE %-6! %-6!
 WAYVALVEADDHE %-6! %-6!
Electric Heater &ACTORYMOUNTED
&ANSTOPTHERMOSTAT 9&34!
Power interface %0)"
-ASTERSLAVEINTERFACE %0)-3!
#ONTROLLERELECTRONIC REMOTE %#&7%2
Type: FWD
4 6 8 10 12 16 18
Description
%LECTRICHEATERSMALL %$%(! %$%(3! %$%(3! %$%(3! %$%(3!
%LECTRICHEATERBIG %$%(! %$%("! %$%("! %$%("! %$%("!
 PIPE WAYVALVE %$-6! %$-6! %$-6! %$-6!
 PIPE WAYVALVE %$-6! %$-6! X%$-6! X%$-6!
6ERTICAL$RAINPAN %$$06! %$$06!
(ORIZONTAL$RAINPAN %$$0(! %$$0(!
&ANSTOPTHERMOSTAT 9&34!
&RESHAIRINTAKE %$-&!! %$-&!! %$-&!! %$-&!! %$-&!!
#ONTROLLERELECTRONIC REMOTE %#&7%2
Power interface %0)"
-ASTERSLAVEINTERFACE %0)-3!
Air conditioning systems provide a significant level of
indoor comfort, making possible optimum working
and living conditions in the most extreme climates.
In recent years, motivated by a global awareness of
the need to reduce the burdens on the environment,
some manufacturers including Daikin have invested
enormous efforts in limiting the negative effects
associated with the production and the operation of
air conditioners.
Hence, models with energy saving features and
improved eco-production techniques have seen the
light of day, making a significant contribution to
limiting the impact on the environment.

Daikin’s unique position as a manufacturer of Daikin Europe N.V. is approved by LRQA for The present leaflet is drawn up by way of information only and
air conditioning equipment, compressors and its Quality Management System in accordance does not constitute an offer binding upon Daikin Europe N.V..
refrigerants has led to its close involvement in with the ISO9001 standard. ISO9001 pertains to Daikin Europe N.V. has compiled the content of this leaflet to the
environmental issues. quality assurance regarding design, development, best of its knowledge. No express or implied warranty is given

Responsible Editor: Daikin Europe N.V.. Zandvoordestraat 300. B-8400 Oostende


For several years Daikin has had the intention manufacturing as well as to services related to the for the completeness, accuracy, reliability or fitness for particular
to become a leader in the provision of product. purpose of its content and the products and services presented
products that have limited impact on the therein. Specifications are subject to change without prior notice.
environment. Daikin Europe N.V. explicitly rejects any liability for any direct or
This challenge demands the eco design and indirect damage, in the broadest sense, arising from or related
development of a wide range of products ISO14001 assures an effective environmental to the use and/or interpretation of this leaflet. All content is
and an energy management system, management system in order to help protect copyrighted by Daikin Europe N.V.
resulting in energy conservation and a human health and the environment from the
reduction of waste. potential impact of our activities, products and
Printed on non-chlorinated paper. Prepared by La Movida. Belgium

services and to assist in maintaining and improving


the quality of the environment.
%0#%. sssCopyright © Daikin

Daikin units comply with the European regulations


that guarantee the safety of the product.
Daikin products are distributed by:

Daikin Europe N.V. participates in the Eurovent


Certification Programme for Air Conditioners (AC).
Liquid Chilling Packages (LCP) and Fan Coil Units
(FC); the certified data of certified models are listed
in the Eurovent Directory.
Certification is valid for air cooled models <600kW
and water cooled models <1500kW.
Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende