30cpu04-Substitute HFA30PA60C

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Bulletin PD-20750 rev.

B 11/01

30CPU04
Ultrafast Rectifier

Features
trr = 60ns
• Ultrafast Recovery Time
• Low Forward Voltage Drop IF(AV) = 30Amp
• Low Leakage Current
• 175°C Operating Junction Temperature VR = 400V
Description/ Applications
International Rectifier's FRED.. series are the state of the art Ultra fast recovery rectifiers specifically designed with
optimized performance of forward voltage drop and ultra fast recovery time.
The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness
and reliability characteristics.
These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as
free-wheeling diode in low voltage inverters and chopper motor drives.
Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.

Absolute Maximum Ratings


Parameters Max Units
VRRM Peak Repetitive Peak Reverse Voltage 400 V
IF(AV) Average Rectified Forward Current Per Leg 15 A
Total Device (Rated VR ), TC = 149°C Total Device 30
IFSM Non Repetitive Peak Surge Current, @ 25°C Per Leg 200
IFRM Peak Repetitive Forward Current Per Leg 30
(Rated VR , Square wave, 20 KHz), TC = 149°C
TJ, TSTG Operating Junction and Storage Temperatures - 65 to 175 °C

Case Styles

30CPU04
Base
Common
Cathode
2

1 3
Anode Anode
2 2
1
Common
TO247AC Cathode

www.irf.com 1
30CPU04
Bulletin PD-20750 rev. B 11/01

Electrical Characteristics @ TJ = 25°C (unless otherwise specified)


Parameters Min Typ Max Units Test Conditions
VBR, Vr Breakdown Voltage, 400 - - V IR = 100µA
Blocking Voltage
VF Forward Voltage - 1.17 1.25 V IF = 15A

- 0.93 1.12 V IF = 15A, TJ = 150°C

IR Reverse Leakage Current - 0.3 10 µA VR = VR Rated

- 30 500 µA TJ = 150°C, VR = VR Rated

CT Junction Capacitance - 28 - pF VR = 400V

LS Series Inductance - 12 - nH Measured lead to lead 5mm from package body

Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)


Parameters Min Typ Max Units Test Conditions
trr Reverse Recovery Time - 36 60 ns IF = 1.0A, diF/dt = 50A/µs, VR = 30V

- 46 - TJ = 25°C

80 TJ = 125°C IF = 15A
VR = 200V
IRRM Peak Recovery Current - 3.6 - A TJ = 25°C
diF /dt = 200A/µs
- 8.7 - TJ = 125°C

Qrr Reverse Recovery Charge - 84 - nC TJ = 25°C

- 345 - TJ = 125°C

Thermal - Mechanical Characteristics


Parameters Min Typ Max Units
TJ Max. Junction Temperature Range - - 175 °C

TStg Max. Storage Temperature Range - 65 - 175

RthJC Thermal Resistance, Junction to Case Per Leg - 0.8 1.5 °C/W

RthJA ! Thermal Resistance, Junction to Ambient Per Leg - - 40


"
RthCS Thermal Resistance, Case to Heatsink - 0.4 -
Wt Weight - 6.0 - g
- 0.21 - (oz)

Mounting Torque 6.0 - 12 Kg-cm

5.0 - 10 lbf.in

! Typical Socket Mount


"#Mounting Surface, Flat, Smooth and Greased

2 www.irf.com
30CPU04
Bulletin PD-20750 rev. B 11/01

100 1000
Tj = 175˚C
100
Tj = 150˚C

Reverse Current - I R (µA)


10 Tj = 125˚C

1
Tj = 100˚C
0.1

0.01
Instantaneous Forward Current - I F (A)

10 Tj = 25˚C
0.001

.0001
T J = 175˚C 0 100 200 300 400
Reverse Voltage - VR (V)
T = 150˚C
J Fig. 2 - Typical Values Of Reverse Current
Vs. Reverse Voltage
T = 25˚C
J 1000
T = 25˚C
Junction Capacitance - C T (pF)

J
1

100

0.1 10
0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 0 100 200 300 400
Forward Voltage Drop - VFM (V) Reverse Voltage - VR (V)
Fig. 1 - Typical Forward Voltage Drop Characteristics Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
10
(°C/W) thJC

1 D = 0.50
Thermal Impedance Z

D = 0.20
D = 0.10 PDM
D = 0.05
D = 0.02 t1
0.1 D = 0.01 t2
Single Pulse Notes:
(Thermal Resistance) 1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC+ Tc
0.01
0.00001 0.0001 0.001 0.01 0.1 1 10 100
t1, Rectangular Pulse Duration (Seconds)
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics

www.irf.com 3
30CPU04
Bulletin PD-20750 rev. B 11/01

180 25
Allowable Case Temperature (°C)

RMS Limit

Average Power Loss ( Watts )


170 20

160 DC 15
D = 0.01
D = 0.02
150 10 D = 0.05
Square wave (D = 0.50) D = 0.1
Rated Vr applied D = 0.2
D = 0.5
140 5 DC

see note (3)


130 0
0 5 10 15 20 25 0 5 10 15 20 25
Average Forward Current - IF(AV) (A) Average Forward Current - IF(AV) (A)

Fig. 5 - Max. Allowable Case Temperature Fig. 6 - Forward Power Loss Characteristics
Vs. Average Forward Current

100 1000
If = 30A
90 If = 16A
If = 8A
80

70
Qrr ( nC )
trr ( ns )

60
100
50
If = 30A
40 If = 16A
If = 8A
30
Vr = 200V Vr = 200V
20 Tj = 125˚C Tj = 125˚C
Tj = 25˚C Tj = 25˚C

10 10
100 1000 100 1000
di F /dt (A/µs ) di F /dt (A/µs )

Fig. 7 - Typical Reverse Recovery vs. di F /dt Fig. 8 - Typical Stored Charge vs. di F /dt

(3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ;


Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR

4 www.irf.com
30CPU04
Bulletin PD-20750 rev. B 11/01

Reverse Recovery Circuit

VR = 200V

0.01 Ω
L = 70µH
D.U.T.

D
di F /dt
dif/dt
ADJUST IRFP250
G

Fig. 9- Reverse Recovery Parameter Test Circuit

3
t rr
IF
ta tb
0

4
Q rr
2
I RRM 0.5 I RRM
di(rec)M/dt 5

0.75 I RRM

1 di fF/dt
/dt

1. diF/dt - Rate of change of current through zero 4. Qrr - Area under curve defined by t rr
crossing and IRRM
t rr x I RRM
2. IRRM - Peak reverse recovery current Q rr =
2
3. trr - Reverse recovery time measured from zero 5. di (rec) M / dt - Peak rate of change of
crossing point of negative going IF to point where current during t b portion of t rr
a line passing through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current

Fig. 10 - Reverse Recovery Waveform and Definitions

www.irf.com 5
30CPU04
Bulletin PD-20750 rev. B 11/01

Outline Table

3.65 (0.144) 5.30 (0.209)


15.90 (0.626) DIA.
3.55 (0.139) 4.70 (0.185)
15.30 (0.602) 2.5 (0.098)
Base
1.5 (0.059) Common
5.70 (0.225) Cathode
5.30 (0.208) 2

20.30 (0.800)
19.70 (0.775) 5.50 (0.217)
4.50 (0.177)
(2 PLCS.)
1 2 3
1 3
14.80 (0.583) Anode Anode
2
1 2
14.20 (0.559) 4.30 (0.170) Common
3.70 (0.145) Cathode

2.20 (0.087) 2.40 (0.095)


1.40 (0.056) MAX.
MAX.
1.00 (0.039) 0.80 (0.032)
3.20 (0.126)
MAX. 0.40 (0.213)
5.47 (0.216)
5.43 (0.213)

Conforms to JEDEC Outline TO-247AC


Dimensions in millimeters and (inches)

Ordering Information Table

Device Code

30 C P U 04

1 2 3 4 5

1 - Current Rating (30 = 30A)


2 - Common Cathode
3 - TO-247AC
4 - Ultrafast Recovery
5 - Voltage Rating (04 = 400V)

6 www.irf.com
30CPU04
Bulletin PD-20750 rev. B 11/01

Data and specifications subject to change without notice.


This product has been designed and qualified for Industrial Level.
Qualification Standards can be found on IR's Web site.

IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 11/01

www.irf.com 7