Professional Documents
Culture Documents
4008 GB
4008 GB
4008 H/S
Visually the best dialysis results
Therapy
Through continuous optimisation of the treatment modalities Fresenius Medical Care always aims to
offer patients the best renal replacement therapy to increase their well being and quality of life.
Our haemodialysis systems 4008 H/S guarantee safety and efficiency of all important treatment
modalities within the scope of renal replacement therapies, such as:
● Bicarbonate or acetate dialysis
● Single-Needle or SN Click-Clack
● Ultrafiltration and sodium profiles
● ISO-UF programme
● Online Haemo(dia)filtration
ONLINEplu s System –
Online Haemo(dia)filtration
DIASAFE®plus –
Dialysis fluid filter
3mix – bibag® –
Online dry concentrates Dry bicarbonate concentrate
Monitoring
The haemodialysis equipment can be adapted by the modular combination of extensive
options to special therapy modalities. The automated acquisition, monitoring and control
of specific patient and machine parameters provide the operator with continuous and
precise assessment of the current treatment situation.
BPM – Blood
Pressure Monitoring
Finesse ®
–
Dialysis data acquisition
and management system
Operation
The ergonomical and logical operating structure representations of treatment parameters and
with clear allocation of operating functions seen in measured values scaled to time. Warning messages
only seven menu screens, permits the user easy give support and ease the operation. The automated
programming of the treatment parameters on the setting of the alarm limits and their intelligent
high-resolution colour screen. Additional information monitoring ensure a treatment almost free from false
of the treatment is provided by the graphical alarms.
Pre-dilution Post-dilution
Balancing
Chamber
DIASAFE®plus
Venous
Bubble
Trap
Haemodiafilter
Substitution
Port Patient
Blood
Arterial Pump
Retentate Rinsing Flow
Valve Bypass Port Chamber
UF Pump Valve
Monitoring
Impulses to improve quality of life!
The „online Clearance monitoring“ The user can specify the prescribed therapy goal and
enables the continuous monitoring of: detect immediately possible deviations during the course
● the effective in-vivo urea clearance (K) of the treatment and perform the necessary corrections.
● the accumulated cleared plasma (Kt) or The measuring technique is:
● the current dialysis dose administered (Kt/V)
● non-invasive
● and the plasma sodium concentration, during
● runs completely automatically
treatment. ● causes no additional treatment costs and
OCM® can also be combined with ONLINEplus Haemo- ● requires no additional disposable, laboratory
diafiltration in pre or post dilution. or staff effort.
AquaUNO*
The single patient reverse osmosis device AquaUNO ● Initial self-test of essential components
is especially designed for the operation of our haemo- ● improved safety feature
dialysis machines in home dialysis and intensive ● recovery of excess per-
care units. The AquaUNO is intended for mobile meate and concentrate
stand-alone use, together with the 4008 H/S dialysis ● monitoring of cleaning
machines. cycles to protect the
The system features: membrane.
● automated circulating rinse with pre-selected
rinse cycles
● optimised cleaning and disinfection programmes
including the permeate supply lines
* in preparation
Technical Data Sheet
Haemodialysis Machines 4008 H and 4008 S
Balancing accuracy
Extracorporeal circuit
± 0.1 % of dialysate flow
Arterial pressure monitoring Ultrafiltration
Display range – 300 mmHg to + 280 mmHg UF rate 0 to 4.00 l/h
Accuracy ± 10 mmHg Accuracy ± 0.5 %
Resolution 20 mmHg Allowed dialyser UF factor unlimited
Venous pressure monitoring Parameters displayed UF goal, UF time, UF rate, UF volume
Display range – 60 mmHg to + 520 mmHg Blood leak detector
Accuracy ± 10 mmHg Sensitivity ≤ 0.5 ml blood/min (Hct = 25)
Resolution 20 mmHg at max. flow 800 ml/min
Transmembrane pressure monitoring
Display range – 60 mmHg to + 520 mmHg Disinfection and
Resolution 20 mmHg cleaning programmes*
Arterial blood pump
Rinse
Blood flow range 10 to 600 ml/min Temperature/flow 37 °C / 600 ml/min
Accuracy ± 10 %
Hot rinse (recirculation)
Single-Needle system
Temperature/flow 85 °C / 450 ml/min
with 2 blood pumps. Internal
pressure/pressure control with variable Cleaning Sporotal® (recirculation)
stroke volume Temperature/flow 37 °C / 600 ml/min
Air bubble detector Hot disinfection Diasteril® (recirculation)
by ultrasound transmission, additional Temperature/flow 85 °C / 450 ml/min
optical monitoring in venous clamp Disinfection Puristeril® 340 (recirculation)
Heparin pump
Temperature/flow 37 °C / 600 ml/min
Delivery range 0 to 10 ml/h
Bolus function max. 5 ml per bolus
Syringe size 20 ml, 30 ml, 50 ml *Various programme combinations selectable
✉
Phone:
D – 61346 Bad Homburg
+49 (0) 61 72- 609-0
Fax: +49 (0) 61 72- 609-8340
E-Mail: dialysis-marketing@fmc-ag.com