Download as pdf
Download as pdf
You are on page 1of 30
FR Kabel, a part of BR Global, is one ofthe leading conglomerates inthe electrical sector. thas always ‘endeavored to create best quality products using the latest advances in wire design and engineering, Working with determination to produce products with best technologies, AR Kabel offers the widest range of premium Wires and cables for various residential, commercial industrial and infrastructure purposes, Being an IS0 9001, 1SO 14001:20044Cor.1:2009, OHSAS 18001:2007 and ISO 5000):201 certified company, FAR Kabel has been accredited with multiple product certifications like CE, BASEC (UK), UL (USA), VDE (Germany), PSB (Singapore) SSO (Saudi Arabia) etc. with REACH and ROHS compliance, the materials used in various products are unique after an extensive research by skilled professionals that make sure every ‘product adheres to all guidelines and standards, We believe thot the future of design tes with innovation tha instigates one to push boundaries, eliminating the borders between sciences, We at RR Kabel believe in this and hence are constantly emerging with new ‘marketing and technical perspectives that are globally significant, aiming to ereate a safe environment for the FIREX LSOH ee bn tae Smoke Zero Halogen) insulation 90°C with UNILAY conductor | Non-Toxie and Non-Corrosive | Does not propagate flame and fire, Application This cable is ideal for use in domestic applications, electrical switchgear, industrial ighting, contro! panels, wiring of switchboards, ear general wing, instrumentation and communication systems. In many counties it mandates te uee Woe an ‘ables in Aultoriums, Hospitals, Hotels, Schools, Stadiums, andallconstructions forpublic usage, Technical Data Senduetor: Thin strands of ectroltic Copper ate multi-drawn for uniformity of Resistance, Dimension and Flexibility. The drawn strands are uni-laid with high precision and compacted. Thus forming a perfectly circular conductor which enables reduction in overall diameter for space savingin high density wiring, Conductor Speciality: The strands donot get cut when stripping the insul sockets. Thus, eliminating spotheating and sparking, Insulation: Polyolefin cross linked ES toBS EN 60963-5 Low Smoke Zero Halogen (LSOH) Insulation Conformity: EN 60332-1-2, EN60332-3&EN 60754-1 &2 Colours: Green, Black, Red Yellow, Blue, Grey, White Marking: The cables are marked FIREX LSOH' Packing: 90 mtrs. Coils packedin protective cartons, Standard: BS EN §0525-3-41 ‘Temperaturerange:-15°Cto+90°C ‘on. The conductor offers perfect contact at pins, terminals and Properties Teeiasttation does not bum realy it doesnot melt and drip, smoke is negligible, transparent, non-toxic. in a fre situation the people contentions seca futfocate. This faciitates firefighting and rescue operations, This cable has extended cern ‘against the conventionally used cables, Ozoneresistant according to EN 60811 Cable Design Parameters finaly complete the part numbers for these cables by adding the suffix (in place of ‘xx for the colour required 01 - Green, 02 - Black, 03 - Red, 04 - Blue, 05 - Yellow, 06 - Grey, 7 = White Nominal Cross Noi Number ‘prox. Overall Max DCCondctr current Rating (Amps) PartMumber Sectional rea Insulation “Max Dia, Diameter Resistance at 20°0 = (Sq-mm) Thickness (mm) strands (am) (om) Gasing concen 7010101360 10 o7 37/019 26 195 v7 15 o1010102%x60 1s o7 s7/0.23 30 naa 2 1a 01010103%x60 25 oa 610.23 36 798 30 2 1010 1044x690 40 os 61/029 4 495 a 33 010101050x60 60 os 9170.29 46 330 53 43 “condor a per 60228, ‘Advantages - FIREX LSOH Vs LSOH Sco, Properties 1 2 ‘Thermal Resistance 3 4 Structure 5 Hygroscopic nature (Higher water absorption ‘educes electrical properties) Test Parameters - FIREX LSOH Test Limited oxygen index Limited temp, index ‘Smoke density (Light absorption) Acid gas generation FIREX LSOH- Crosslinked ‘Max operating temperature $0°C ‘Nochange under heat Max, short rut tmp. rating 280°C 2-Dimensiona Non Hyarosconic Higher diet trength Higher curent carving capacity Test Method ASTI-0 2863 | ASTD 2963 AsTieD 2343 veo-so7s4-1 SOH-Themoplastc (Other Products) ‘Max. operating temperatire 70°C Deform and eoften under heat ‘Max. short circuit temp. rating 160°C Usually near strvture Comparatively hygroscopic Lone diet stength Lower current caring capacity 220% sa600 79% Limited Temperature index Is 10810 64 > 250°C ‘Smoke Density (Light Absorption) 18 13960 P -6/Sec 9 60% ‘Acid Gas Generation 1810810 P -59 <20% SUPEREX FR REACH | ROHS | CE India's 1" REACH and RoHS Compliant Cable | Flame Retardant Cable. Application Suitable for wiringin all ypes ofresidentil and commercialinfrastructute, where fire and electrical safetysutmostimportant. Technical Data Approvals :1S 694 marked, FIA/TAC Voltage Grade: Up to andincluding 1100V aatuctor; Thin strands of electrolytic copper are multi-dravin for uniformity of resistance, dimension and flexibly, The strands ate ‘twisted with high precision to impart circularity for the conductor. Mrenation: Specially formulatedheat resistant & lame retardant PVC insulation is used, The FR property retards the propagation of flame without compromising safety. Insulation Conformity :|S 5831, TypeA+FR Colours: Red, yellow, blue,black, green, grey & white ‘Marking ‘The cables are printed with marking of SUPEREXF' upto 4 Sq, mm &"RA KABEL FR" for size6 Sq, mmandonwards Packing : 90 mtr. coilis packed in protective cartons. Project packing of 180 mtr. also available Cable Design Parameters ly.complete the part numbers for these cables by adding the suffix inlace of xx) for the colour required 01 - green, 02 black. 03- red, 04 blue, 05 - yellow, 06 - grey, 07 - white. Nominal Cass Nominal Number ‘opr Overall Max. DCConucer current Rating (Amps) Part Wumber Sectional rea Insulation “Nominal Dis, Diameter Resistance at 202 (qm) Thickness (mm) of strands (om (oven) Casing Concealed 01010101 x%50 05 06 we/0.2 2a 390 5 4 10101020470 075 os 240.2 23 260 ° 8 o1010103%%90 1 oz 403 27 tet “ 13 01010106070 15 or 22103 30 yaa 18 16 010101050090 25 08 36/08 az 741 24 20 01010106190 4 08 56/03 aa 495 20 26 01010107%~0 6 os eos 46 3.30 38 33 01010108090 10 10 woos 70 191 82 4s 0101010940 16 10 126/04 an 121 10 6 Contr apr is 6199 Properties Test Test Method Values Limited Oxygen index 15 10810 P-s8 229% Limited Temp, Index 1810810 P-64 >250°C RATNACOM oe iene ve ‘Low Attenuation and Minimised ross Talk | FlameRetardant Jacket Application Recommended for switchboard and telephone wiring in esidentials and commercial infrastructure, for transmission of analog and digital signals, wiringin faxes, modems, alarm enunciators, data recording/acquisition systems and various communication devices. Technical Data Specifications :T0-S/WS113C Conductor: The central conductoris made of solid electrolytic grade of copper Premium quality grade polyethylene used ona special extruder. This serves for low attenuation andminimised cross talk The cores are carefully twisted with suitable lays and bunched together Marking: The cables are marked’RATNACOM FR’ Packing: Availablein 100 mtr length in polybag, Higher lengths available on special request. Cable Design Parameters art Numbers Sie (mm) No. of Pairs ‘Approx. Overall Diameter (rm) ‘010600221040 oa 2 39 ‘010600321040 os 3 43 ‘10600421040 04 4 47 ‘010600521040 os 5 52. ‘ovasor021040 04 0 65 10802021040 oa 20 92 19800221050 os 2 42 010600321050 os 3 ar 10600421050 os 4 51 10600521050 08 5 57 10601021050 05 0 70 010602021050 05 2» 100 Electrical Parameters ‘sine lectrcal Parameters 05mm 4mm De conductor resistance 92.20 0/Km at 20°C max. 143.0 a/km at 20°C max. Mutual capacitance 50 nF/kmn max. Insulation resistance in air 110000 M-2/Km Capacitance unbalance - pair to pair 250 pF/100m max Capacitance unbalance - pair to ground 380 pF/100m max. Resistance unbalance 5% max, RR KABEL RATNALAN CAT 5e/6 Rotts $$ —_ ae 38 — Application GAT EUTP cables ar high performance cables used increasingly for modern computer network systems, These cables form the back ‘bone of modern data transmission in industries, residential and commercial infrastructure. Technical Data Performance : RATNALAN enhanced CAT 6 UTP capable of handling 100 + Mbps data rates. RATNALAN CAT Se UTP is independently verified to exceed the requirements of €N 50173, ISO/IEC 11801 and TIAVEIA S68-B-1/8-2 Cable Construction Conductor: Solid bare copper Colour Code Insulation : High density polyethylene 1 Pair: White - orange stripe and orange Pair: 2 Insulated conductors twisted together 2 Pair: White - green stripe and green Outer Jacket : FR PVC 3 Pair: White - blue stripe and blue 4 Pair: White - brown stripe and brown Packing Availabe in easy pull box of 101 mtr and 305 mtr for CAT Se and CAT 6 is availabe only in 305 mts, pack Te case cars art Number 10701014094 oro7or014194 ‘Mechanical and Envonmenta Properties ‘Aoplicabl International Standards fr Cable Construction Mex TensileLoad : 10Kgs. per simplex cable (Installation) Is0/1EC 11801-2002 Min, Bend Radius 8 x Outer Diameter (Installation) Isovtec 6116-5 4x Outer Diameter (Operation) EN 50173 -1:2002 Temp. Installation: o'C to 450° EN 50288-3-1 ‘Temp.-Operation : 10°10 +60%e ANSI/TIA/EIA 5688-2:2002 Electrical Parameters at 20°C ‘Typical Peformance Electrical Characteristics at 20°C ‘Specification aT se cars Conductorloopresistance Max.190/100m 160/100m 140/100m Conduetorresistanceunbalance Max. 2% 05% 05% Dielectric strength V.OKVOCOrO.7KVACIor1min. —_-100%inprocesstest 1OOinprocess test Insulationresistance >500M0/Kmat100-S00Vtestvoltage »500M0/Km 3600 MO/Km Capacitance unbalancetoearth Max. 160pF/100m 40pF/100m 40pF/100m Velocity ofpropagation <634nsee/100mat OOMHe 496nsec/100m at 100 MHz 490nsec/100mat 100 MHz (NvPforhandheldtesters =0.69) (NV for handheld testers = 0.69) Skew Max.40nsec/100mati0OMHz Max. 25nsee/100mat 100MHz Max. 30nsec/100m at 1DO Mie Mean characteristicimpedance _1000:+50at 100 MHZ 10003081 100MHz 1000:+ 30. 100 MHz Couplingattenationupto Ghz Min. 4048, 508 568 Typical Headroom Characteristics - CAT Se Frequency (M2) 1 4 10 16 3125625001558 00S 00 Insertion Loss (48/100m) Specvalue 20 © 41 «6S B23... WANA WIR Typicalvalue 18 36 58 74 83 105 153 198 254 24 334 NexT (48) Specvalue 65.3 96.3 503473458 AZ99BA ANIA NANA Tyicalvalue 733 643 583-552 538509 ABA. 4A BTS PSNEXT (48) Specvalue 629 633 473 a2 289.9 NA NA ONIN Typicalvalue 713 62.9 563 5821848944. BA HBSS ELFEXT (48,100m) Specvalue 638 51.8 438-987-378 339 279238 WA WANA. ‘Typicalvalue 788 668 © 588 «SAT «5284899 BA 350 PSELFEXT (db/100m) Speevalue 608 «488 «408357 ©9489 K9 OBA NANA Typicalvalue 768 648 S68 527 $08 4594S R80 RN Fetun Loss (4B/100m) Spec value N/A 28.1 250-250-250 236.- 21501 NANA OWA Typicalvalue 250 280 300-300 30038555. BOR ‘ACR (48/1 00m) Typical value 715 607 525 478455 4043S PSACR (48/100) Ticalvalue 635 587 505 458 4359841 STO ‘Typical Headroom Characteristics - CAT 6 Frequency (MH) 1 4 1 16 3125250085200 380, Insertion Loss (dB/100m) Specvae 20 38 60 76 85 07 154 198 290 9728 WA Typicalvalue 19 88 «557207899181 TH] D Next (48) Specvalue 660 653599562 4B GTA 44 9B 98SNIA, ‘Typicalvalue 865 75 71.8 684 67.0641 896552050499 PSNEXT (aa) Specvalue 640 639 S73 542528 «499 ASAT 883 NIA Typicalvalue 645 755 695 664 650 G21 B74 SDDS TS ELFEXT (48/100) Specvalue 660 68.0 500 459 440 40.1381 902020 ‘Typical value 85.0 © 730 65.0 609580851 «49.1 450990870 aS PSELFEXT (db/100m) _Specvalue 040 55047042910 97.3.) 2O 1.0180 ‘Typicalvalue 820 70.0 620 S79 860-521-454 42035034025 Fetum oss (d8/100m) Specvalue N/A 230-250-250 280236 = «216-201 180173WNA Typicalvalue 27.0 900-300-300 300 286-6851 280231 ‘AOR (¢8/100m) Typicalvalue 846 739 660 614 59.1542 45S WH 59H PSAGR (48/100) Typicalvalue 826 71.9 64058071825 AS 8S 239 RATNA CO-X fore ~“_ Application High quality co-axial for cable TY network for notch free attenuation values over wide range of frequencies. The special jacketing offers incteasedlife even nruggedconditions. Technical Data Conductor: The central conductor is made of solid electrolytic grade annealed plain copper conductor, which has distinct advantages over traditional copper conductor {Insulation : The insulation provided over the conductor is of foam PE which acts as a dielectric Sereen Aluminium mylar tape is provided over the insulated conductor to shield the conductor and ensure disturbance free transmission of signals Braiding: The braiding is generally provided with 60% coverage of ATC (Annealed Tinned Copper) / Alalloy Marking: The cables are marked 'RATNAGO-»" Cable Design Parameters Cable Type Construction Details G59 F AG6F AGN Part Number 10501010791 ‘010501020791, ‘010501030791 Inner conductor Copper Copper copper Nominal Diameter (mm) og 102 163 Dielectric Foam PE Foam PE Foam PE Nominal Diameter (mm) 35 45 70 Fist Bonded Al Tape Bonded Al Tape Bonded Al Tape Outer Conductor Second Tinned CUA Braid Tinned Cu/A! Braid Tinned Cu/Al Braid Nominal Coverage (%) 60 60 60 PVC Jacket Black Black Black Nominal Cable Diameter (me) 62 70 100 “BOF ial avaiable ith CCS conduc andthe appleble Pat unter shal b 10801048751 Cable Type - Armoured Construction Details AG S9F AG6F Ag iF Part Number ‘010501050791 ‘010501060781 010501070791 Nominal Cable Diameter (rm) 105 na M46 "06ers ave with CCS conductor ante appl Pat unser shall be 0501080791. Electrical Parameters Cable Type ee RGSSF AGGF ‘RGTIF Inner Conductor-Mas Resistance at 20°C (2/100m) 08 a ous Nominal Capacitance (f/m) 3 59 83 Characteristic impedance (0) 5 6 6 Velocity of Propagation (3) 88 85 85 Dislectrie Strength (KY) 7 "1 "1 Minimum Bending Radius (en) 5 65 60 Maximum Attenuation at 20°C (48/100) at Max. Max Max. SMe 12 19 28 50 Mie a 53 67 100 Mee 42 10 88 200 Mite 60 a9 124 250 Mie 67 105 134 200 Mie 1a ns M46 a50 MMe 19 24 187 soo Mie as 133 167 450 Mie 90 43 wa 00 MHz 98 us 187 560 MHz 99 187 195 600 Miz wos 164 20a 750 Mi na 183 na 800 Mie 124 195 245 900 mite 130 201 a7 1000 MHz 42 24 266 FIRE ALARM CABLES REACH | Rous 1 cE Sire Application These cables are used in high rise buildings, commercial complexes, schools and educational institutions, hospitals, ete for the Connection with security systems lite smoke detectors, emergency lightings, exit signboards and fire command center. These cables are used where the fire safetyis utmostimportant, ‘Standard 8S 7629-1, BS 6387, BSEN 50200 Technical Data Voltage Rating: 300/500V ‘Temperature Range: -30°C to + 70°C (The cable should not be flexed when either the ambient or: ‘cable temperature is below 0°C) Minimum Bending Radius: 6D Cable Type-1 FFX200 05mS0Z1-A- CU/MGT/SR/OSCR/LSOH 300/S00V Class 2. Cable Construction Plain annealed copper conductor to BS EN 60228, class 2. Primary insulation of glass mica ireresistanttape. ‘Secondary insulation of high performance siliconerubber. £12t08S 7658 Section .1 Corecolours: 2Core: blue, brown, 3Core: blue, brown, black. ‘4Core: blue, brown, black, grey. Glass fiber tape. Earth/Drain wire of annealed tinned copperto BS EN 60228. Electrostatic screen of aluminium fire barrier Sheath typeLTS3toBS 7655 section 6.1 Properties Low smoke zero halogen (LSOH), flame retardant. Fire Performance Tests 8S7629--1, 300/ 500V freresistantelectiic cables withnon corrsivegases and ow emission of smoke when affectedby fre. Sategory STANDARD 30& STANDARD 60 when testedin accordance with BS EN 50200-Methodof test for resistance tofreof unprotected small cables for useinemergency circuits, Also meets category ENHANCED 120 when tested in accordance with BS EN 60200 and the 120 min survival time when tested in accordance with BS 6434-2, 8S 6387 CWZ, specification for performance requirements for cables required to maintain crcuitintegrty under ireconditions Meets requirement for fire resistant cables as described in clause 26 2e of BS 5839-1. Cable Design Parameters a No, of Cores & Nominal No.of Stands? Nominal veal ‘ross Section rea (4. mm) ‘Stand Diameter (mm) Diameter (nm) Yoot90201105 2x18 71053 96 100100201205 2425 710.87 no 100100301105 3x18 17083 101 100100301205 3x28 vost ngs 100100401108 axis W058 mt 100100401208 4025 i067 130 Electrical Properties No.of Cores & Nominal Ma Conductor Curent Rating (A) Vetage ep Part Number ‘Goss Section Area Resistance at 20°C 0C or Single Cor single Cor Single Phase AC (Sqm) (kn) Phase ACenclosed Phase AC Clipped (ovat) 100100201105 2x18 ya ws 200 Ey 100100201205 2x25 7a 240 210 8 vooT90301108 3x18 va 175 200 29 To0100301205 3x25 1a 240 270 18 100100407105 4x18 ya 178 200 29 voot90407205 4125 71 240 270 18 Cable Type - 2 FFX200 05S0Z1-U - CU/SR/OSCR/LSOH 300/500V Class 1. Technical Data Plain annealed copper conductorto BS EN 60228, class 1 Insulation of high performance ceramified silicone rubber. E12t0BS 7655 Section 1.1 Corecolours: 2Core: blue, brown, 3Core: blue, brown, black. Core: blue, brown, black, grey. Glass fiber tape. Earth/Drain wire of annealed tinned copper to BS EN 60228. Electrostatic screen of aluminium fire barrie. Sheath TypeLTS3 toBS 7655 section6.1 Properties Low smoke zero halogen (LSOH), flame retardant. Fire Performance Tests 8S 7629-1, 300/500 Vfireresistant electric cables with non corrosive gases andlow emission of smoke when affectedby fire. Category STANDARD 60 when tested in accordance with BS EN 50200-Method of test for resistance to fire of unprotected small cables for sein emergency circuits. {naddition it shall meet the 30 min survival time when testedin accordance with BS EN 50200, Annex, Meets requirement forthe fire resistant cables as describedin clause 26 2d of BS 839-1 8S 6387 CW2, specification for performance requirements for cables required to maintain circuit integrity under fie conditions. Cable Design Parameters No.of cores & Nominal Part Number (ross Seton ea (Sq. mm) 100200200001 ae 100200201105 axis 100200201208 2x25 100200300001 an 100200301105 axis 100200301205 3x25 100200400001 ant 100200401105 axis 100200401208 4x28 Electrical Properties No.of Cores LNomins! Ma. Conductor ina a) Votag rp Par Number (loss Section Area Resistance at 20°C OC or single cor Single cer Single Phase AC (umm) (Gh) Phase ACenclsed Phase AC Clipped (avian 100200200001 2x1 181 131 185 44 100200201105 2x15 12) 178 200 29 100200201205 2x25 741 240 m0 18 100200300001 ant wen 1a 155 a 100200301105 ax1s va Ws 200 29 100200301205 anes 7a 240 m0 18 100200400001 an yen 131 155 “ 100200401108 4x15 v1 v5 200 29 100200401208 4x28 a 240 20 8 Cable Type - 3 FFX200 05mZOZ1-R - Cu/MGT/LSOH /OSCR/LSOH 300/500V Class 2 Technical Data Plain annealed copper conductor to BS EN 60278, class 2 Primary insulation of glass mica fireresistant tape ‘Secondary insulation to BS EN 50363-5, Type E15, Low smoke zero halogen (LSOH) cross-linkable flame retardantinsulation, 3.Core: Blue, Brown, Black 4 Core: Blue, Brown, Black, Grey, Glass fibertape. Earth/Drain wire of annealed tinned copper to BS EN 60228, Electrostatic screen of aluminium firebarrier. Sheath TypeLTS3 toBS 7655 section6.1 Properties Low smoke zerohalogen (LSOH), flame retardant. Fire Performance Tests 8S7629- 1, 300/ 800 fireresistant electric cables with non corrosive gases and ow emission of smoke when affectedby fre Category STANDARD 60 when tested n accordance with BS EN 50200-Method of test for esistancetto fire of unprotected amalleables for useinemergency circuits. ‘maddition, it shall meet the 30 min survival time when tested in accordance with BS EN 50200, Annex. Meets requirement for the fireresistant cables as described in clause 26 2d of BS 6839-1 '8S 6387 CWZ, specification for performance requirements for cables required to maintain circuit integrity under ire conditions. Cable Design Parameters aie, No.of Cores & Nominal No.of Stands Nominal Over ‘Approx. cable ‘rss - Seton Aa (8q, mm) ‘Stand Diameter (nm) Diameter (rm) ‘Kathe 1100300201105, 2x15 71053 a7 7 100800201205 2x25 067 nz 168 1100300301108, axis 71053 103 148 100300301205 3x28 tW0sr ns 24 100300401105 ans 71083 ns 185 100800401205 4025 vost 133 269 Electrical Properties No.of Cores & Nominal Mas Conductor Curent Rating (a) Vaage Drop Par Number ross Section Ares Resistance at 20°C DC or Single Cor single Cor Single Phase Ac (Sq. mm) (aiken) ‘Phase AG enclosed Phase AC Clipped iain) 100300201105 2x15 yaa 18 200 29 100300201208 2x28 a 240 20 18 10300801105 3x18 v4 175 200 29 00300301205 3x28 ma 240 20 18 1100300401108 nis ya 17s 200 2 100300401205 4x25 7a 240 70 8 Code Designations FEX~ Fire Alarm Cable, 200 ~ 300/500 V Multicore (Type), 05 ~ 300/500 V (Voltage), mS ~ Mica Tape + Silicon Rubber, m2—Mica Tape + ThermosettingLSOH, S ~ silicon Rubber, O - Overall Aluminium screen, -LSOH, U- Solid conductor to EN 60228 class 1, ~ Stranded conductorto EN 60228 class 2 SPEAKER CABLE Application ‘Speaker cables are highly recommended for use in connecting speakers, public address system forclear and distortion free voice with low Bios. Cable Construction {The cables are manufactured with bright annealed plain flexible electrolytic grade copper conductor, bunched compactly, insulated with specially formulated PVC compound. Fach core is uniquely designed for easy identification, inorder to offer uniform capacitance throughout length the distance between the two conductors is maintained uniformly, Colour Availabilty: Transperent/ black’ white with ed tracer for polarity identification. Also availablein grey. Packing: Thedeliverylengthisavalablein 100 mtr. coils Cable Design Parameters {inaly complete the pat umbers forthese cables by adding the suffix (nplace ox for colour require: (00- Transparent, 02- black,07- white, 12 grey Conductor Construction axmum Ove = 4 Emil Ane Noni sana sc eateena eel 19010 ecto 2 05 380 42x21 orosovozxe10 9 076 260 arx24 010801088110 8 1 195 57x29 o108010¢0x10 6 1s 139 60x30 o10s0105ex10 “ as 798 10x36 01080106210 2 ‘ 498 eaxat 109010710 10 6 a0 96x47 Recommended length Wire Sze 20oad Dead load en oad 2AWG 381@9m) sit (1.8m) si 27m) 12 15m) 19awa 50.5) oH (am) 15f (45m) 201(6m) sans stam) eh (49m) 2ate(z3m) s2tt(@7m) T6AWG ‘Taft (3.6m) 24ft (7.3m) 36ft (11m) 4B ft (15m) vaane 208 (6.1m) ot (12m) «on (18m) sot (24m) 12AWG 30t (2.1m) sof (18m) sot (27m) "af (36m) roAwa Sort (15m) 1001 (30m) 1501 (6m) 201 (61m) RR KABEL

You might also like