ABSORBABLE SUTURE
Practicryl 910
Braided PGLA
Type Tissue reaction
Braided and coated multifilament Minimal
Composition Absorbtion
Polyglactine 910, a copolymer made of 90% glycolide and The hydrolytic action by which the material is broken down
10%L-lactide results in total absorption between 56 and 70 days. Between
40% and 50% of tensile strength remain after 21 days.
Coating Presentation
Poly-glycolide-co-L-lactide and calcium stearate (<1%) Box with 12 sutures
Colour
Violet / Beige - undyed
Braided PGLA
CHARACTERISTICS
High tensile strength Coated multifilament
+ Excellent tissue support + Soft passage through the tissues with minimal sawing,
tissue drag and trauma
Synthetic
+ Good knot tie down / adjustability
+ Minimal tissue reaction
+ Reduced capillary action
Breaks down by hydrolysis
Hermetically sealed packing
+ Predictable absorption rate
+ Guaranteed seal and product sterility
Braided structure
+ High flexibility
80%
+ General surgery + Gynaecology
70%
50%
+ Gastrointestinal surgery + Orthopaedics 40%
30%
+ Plastic surgery + Urology
20%
0 1 2 3 4 5 6 7 8 9 10 11 12 Weeks
7 14 21 28 35 42 49 56 63 70 77 84 Days
CONTRAINDICATIONS
- Cardiovascular surgery
- Neurosurgery
Absorption
0% 50% 100%
- Being absorbable not to use when an extended wound
support is required.
0 1 2 3 4 5 6 7 8 9 10 11 12 13 Weeks
- Caution in patients with delayed wound healing (e.g. com- 7 14 21 28 35 42 49 56 63 70 77 84 91 Days
promised immune system).
Composition Absorbtion
Polyglycolic acid The hydrolytic action by which the material is broken down
results in total absorption in approximately 60 to 90 days.
Approximately 50% of tensile strength remain after 21 days.
Coating
Polycaprolactone and calcium stearate (1%) Presentation
Box with 12 sutures
Colour
Violet
+ Excellent tissue support + Soft passage through the tissues with minimal sawing,
tissue drag and trauma
Synthetic
+ Good knot tie down / adjustability
+ Minimal tissue reaction
+ Reduced capillary action
Breaks down by hydrolysis
Hermetically sealed packing
+ Predictable absorption rate
+ Guaranteed seal and product sterility
Braided structure
+ High flexibility
80%
+ General surgery + Plastic surgery
70%
50%
+ Gastrointestinal surgery + Ophthalmic surgery 40%
30%
+ Gynaecology + Orthopaedics
20%
+ Obstetrics 10%
0 1 2 3 4 5 6 7 8 9 10 11 12 Weeks
7 14 21 28 35 42 49 56 63 70 77 84 Days
CONTRAINDICATIONS
- Cardiovascular surgery
- Neurosurgery
Absorption
0% 50% 100%
- Being absorbable not to use when an extended wound
support is required.
0 1 2 3 4 5 6 7 8 9 10 11 12 13 Weeks
- Caution in patients with delayed wound healing (e.g. com- 7 14 21 28 35 42 49 56 63 70 77 84 91 Days
promised immune system).
Composition Absorbtion
Polyglycolic acid The hydrolytic action by which the material is broken down
results in total absorption in approximately 42 days. Ap-
proximately 50% of tensile strength remain after 7 days.
Coating Presentation
Polycaprolactone and calcium stearate (1%) Box with 12 sutures
Colour
Beige - undyed / Violet
+ Excellent tissue support + Soft passage through the tissues with minimal sawing,
tissue drag and trauma
Synthetic
+ Good knot tie down / adjustability
+ Minimal tissue reaction
+ Reduced capillary action
Breaks down by hydrolysis
Hermetically sealed packing
+ Predictable absorption rate, quick mass absorption
+ Guaranteed seal and product sterility
Braided structure
+ High flexibility
80%
+ Plastic surgery + Ophthalmic surgery
70%
(Conjunctiva)
+ Obstetrics (Episiotomy 60%
40%
+ Gynaecology 30%
20%
+ Urology (Circumcision)
10%
0 1 2 3 4 5 6 7 8 9 10 11 12 Weeks
CONTRAINDICATIONS 7 14 21 28 35 42 49 56 63 70 77 84 Days
- Cardiovascular surgery
- Neurosurgery Absorption
- Ligation
0% 50% 100%
Monofilament PGCL
Type Tissue reaction
Monofilament Minimal
Composition Absorbtion
Polyglecaprone 25, a copolymer made of 75% glycolide The hydrolytic action by which the material is broken down
and 25% e-caprolactone results in total absorption in approximately 90 to 120 days.
Approximately 60% of tensile strength remain after 7 days.
Coating Presentation
None
Box with 12 sutures
Colour
Violet / Beige - undyed
Monofilament PGCL
CHARACTERISTICS
High initial tensile strength Pliability and softness
Braided structure
80%
+ General surgery + Gynaecology
70%
50%
+ Plastic surgery 40%
30%
+ Gastrointestinal surgery
20%
10%
CONTRAINDICATIONS 0 1
7
2
14
3
21
4
28
5
35
6
42
7
49
8
56
9
63
10
70
11
77
12
84
Weeks
Days
- Cardiovascular surgery
- Neurosurgery
- Ophthalmic surgery
Absorption
- Being absorbable not to use when an extended wound 0% 50% 100%
support is required.
Monofilament PDO
Type Tissue reaction
Monofilament Minimal
Composition Absorbtion
Polydioxanone, a polymer made from polyester poly (p- The hydrolytic action by which the material is broken down
dioxanone) results in total absorption in approximately 180 to 210 days.
Approximately 50% of tensile strength remain after 42 days.
Coating Presentation
None
Box with 12 sutures
Colour
Violet
Monofilament PDO
CHARACTERISTICS
High initial tensile strength Pliability and softness
80%
+ General surgery + Gynaecology
70%
50%
+ Ophthalmic surgery + Urology 40%
30%
+ Orthopaedics
20%
0 1 2 3 4 5 6 7 8 9 10 11 12 Weeks
7 14 21 28 35 42 49 56 63 70 77 84 Days
CONTRAINDICATIONS
- Cardiovascular surgery
- Neurosurgery
Absorption
- Prosthetic devices 0% 50% 100%
Monofilament Catgut
Type Tissue reaction
Twisted multifilament with a monofilament appearance Moderate
Composition Absorbtion
Strands of purified collagen taken from the serosal layer of By phagocytosis. Complete mass absorption in approxima-
selected bovines. Origin from BSE-free classified countries. tely 63 days. Approximately 50% of tensile strength remain
after 7 days. When used in infected tissues or in tissues with
increased levels of proteolytic enzymes (stomach, cervix,
None
Presentation
Colour Box with 12 sutures
Ivory
Monofilament Catgut
CHARACTERISTICS
High tensile strength Uniform diameter by centerless polishing
(monofilament appearance)
+ Excellent tissue support
+ Soft passage through the tissues without sawing, tissue
Absorption by phagocytosis
drag and trauma
+ Uniform absorption
+ Excellent knot tie down
Twisted structure
Hermetically sealed packing
+ Excellent handling properties
+ Guaranteed seal and product sterility
+ High flexibility
80%
+ General surgery + Urology
70%
50%
+ Gynaecology 40%
30%
+ Obstetrics
20%
10%
CONTRAINDICATIONS 0 1
7
2
14
3
21
4
28
5
35
6
42
7
49
8
56 63
9 10
70
11
77
12
84
Weeks
Days
- Cardiovascular surgery
- Neurosurgery
Monofilament Catgut
Type Tissue reaction
Twisted multifilament with a monofilament appearance Moderate
Composition Absorbtion
Strands of purified collagen taken from the serosal layer of By phagocytosis. The rate of absorption is slowed down by
selected bovines, tanned with chrome salts. Origin from BSE- chromizing. Complete mass absorption in approximately 70
free classified countries. days. Approximately 50% of tensile strength remain after
14 days. When used in infected tissues or in tissues with
increased levels of proteolytic enzymes (stomach, cervix,
None
Presentation
Colour Box with 12 sutures
Dark brown
Monofilament Catgut
CHARACTERISTICS
High tensile strength Uniform diameter by centerless polishing (monofilament
appearance)
+ Excellent tissue support
+ Soft passage through the tissues without sawing, tissue
Absorption by phagocytosis
drag and trauma
+ Uniform absorption
+ Excellent knot tie down
Twisted structure
Hermetically sealed packing
+ Excellent handling properties
+ Guaranteed seal and product sterility
+ High flexibility
Hermetically sealed packing
+ High tensile strength
+ Guaranteed seal and product sterility
+ Excellent knot security
80%
+ General surgery + Urology
70%
50%
+ Gynaecology 40%
30%
+ Obstetrics
20%
10%
CONTRAINDICATIONS 0 1
7
2
14
3
21
4
28
5
35
6
42
7
49
8
56
9
63
10
70
11
77
12
84
Weeks
Days
- Cardiovascular surgery
- Neurosurgery
Monofilament PP
Type Tissue reaction
Monofilament Minimal
Composition Absorbtion
Polypropylene, a polymer of propylene Non absorbable
Coating Presentation
None Box with 12 sutures
Colour
Blue
Monofilament PP
CHARACTERISTICS
High tensile strength, non absorbable Pliability and softness
INDICATIONS
General soft tissue closing and/or ligation
especially in :
Nylon monofilament
Type Tissue reaction
Monofilament Minimal
Composition Absorbtion
Extrusion of polyamide 6.0 or 6.6 Non absorbable, gradually encapsulated
by connective tissue. The thread mass
Colour Presentation
Box with 12 sutures
Blue or Black
Nylon monofilament
CHARACTERISTICS
High tensile strength, non absorbable Pliability and softness
INDICATIONS
General soft tissue closing and/or ligation
+ Plastic surgery
+ Gastrointestinal surgery
+ Gynaecology
+ Obstetrics
+ Orthopaedics
Braided NYLON
Type Tissue reaction
Twisted and coated multifilament Minimal
Sizes 5/0 and 6/0 monofilament
Absorbtion
Composition Absorption Non absorbable, gradually encapsulated
Polyamide 6.6 strands enclosed in a by connective tissue
polyamide 6 sheet
Presentation
Colour Box with 12 sutures
Black
Braided NYLON
CHARACTERISTICS
High tensile strength, non absorbable Multifilament in a sheath
+ Excellent and permanent tissue support + Soft passage through the tissues without sawing,
INDICATIONS
General soft tissue closing and/or ligation
+ Skin closure
Braided POLYESTER
Type Tissue reaction
Braided multifilament Minimal
Composition Absorbtion
Polyester - a polymer of polyethylene Non absorbable, gradually encapsulated
terephthalate by connective tissue
Coating Presentation
Silicone Box with 12 sutures
Colour
Green or white
Braided POLYESTER
CHARACTERISTICS
Unsurpassed tensile strength, non absorbable Coated multifilament
+ Excellent and permanent tissue support + Soft passage through the tissues with minimal sawing,
INDICATIONS
General soft tissue closing and/or ligation
especially in :
+ Cardiovascular surgery
+ Ophthalmic surgery
+ General surgery
+ Skin closure
+ Orthopaedics
+ Gastrointestinal surgery
+ Obstetrics
+ Good and extended tissue support + Soft passage through the tissues with minimal sawing,
for up to 3 month
+ Tissue drag and trauma
Braided or twisted structure
+ Good knot tie down / adjustability
+ Excellent handling properties
+ Reduced capillary action
+ High flexibility
Hermetically sealed packing
+ High tensile strength
+ Guaranteed seal and product sterility
+ Excellent knot security
INDICATIONS CONTRAINDICATIONS
General soft tissue closing and/or ligation General soft tissue closing and/or ligation
especially in : especially in :
+ Oral surgery
+ Gastrointestinal surgery
+ Gynaecology
+ Obstetrics
www.aipsutures.com
ABSORBABLE SUTURE
Practicron Braided POLYESTER
www.aipsutures.com
ABSORBABLE SUTURE
Practisilk Natural Silk
www.aipsutures.com
NON-ABSORBABLE SUTURE
Practisteel Steel wire
www.aipsutures.com
ABSORBABLE SUTURE
Practicryl RAPID
Braided PGA Rapid
www.aipsutures.com
ABSORBABLE SUTURE
Practisorb
Monofilament PGCL
www.aipsutures.com
ABSORBABLE SUTURE
Practimono
Monofilament PDO
ABSORBABLE SUTURE
Practigut plain
Monofilament Catgut
www.aipsutures.com
ABSORBABLE SUTURE
Practigut chrom
Monofilament Catgut
www.aipsutures.com
ABSORBABLE SUTURE
Supramono PP
www.aipsutures.com
ABSORBABLE SUTURE
Monopractilon Nylon Monofilament
www.aipsutures.com
ABSORBABLE SUTURE
Polypractilon
Braided NYLON
www.aipsutures.com
More informations ?
A special request? We can manufacture.
www.aipsutures.com
Rue des Artisans, 2 • B-4877 OLNE • BELGIUM • +32 (0)42 272 423 • info@aipmedical.com