Footing F1
Input Load Combination:
Width along x, a 500 mm x-direction
Width along y, b 500 mm y-direction
Grade of concrete,fck = 20 N/mm2 Pu (kN) Mux(kNm) Muy (kNm)
2
Grade of steel, fy = 500 N/mm 454.408 14.7987 14.9945
Clear cover 50 mm P (kN) Mx(kNm) My (kNm)
Safe bearing pressure 150 kN/m2 333.23 9.87 10.00
Loading condition Normal ey = 0.033 m
Safe bearing pressure for given loading 150 kN/m2 ex = 0.033 m
Quick Check
Calculated length 1.49 m Suggested Length 1.5 m (X-dimension)
Calculated width 1.49 m Suggested width 1.5 m (Y-dimension)
Pressure at corner points
at (-0.75,0.75) = 147.87 OK at (0.75,0.75) = 183.41 NOT OK
at (-0.75,-0.75) = 112.79 OK at (0.75,-0.75) = 148.34 OK
Check for development length: Provide Ld Check for bearing pressure: SAFE
Check for X-direction Check for Y-direction
Required d for moment 112.47 mm Required d for moment 112
Provide D 400.00 mm Provide D 400.00
Diameter of bars 12 mm Diameter of bars 12
Calculated Spacing 284 mm Calculated Spacing 284
Provided spacing 150 mm Provided spacing 150
Check for two way shear SAFE Check for two way shear SAFE
Check for one way shear SAFE Check for one way shear SAFE
Calculations
2
Area of footing required, LB 2.22 m
a-b = 0 mm
𝐿^2−(𝑎−𝑏)𝐿−𝐿𝐵=0 Ref. S.N Sinha
L= 1.49 m Provide 1.5 m
B= 1.49 m Provide 1.5 m
Area provided = 2.25 m2
Moment of Inertia about X axix, Ix = 0.42 m4
Moment of Inertia about Y axix, Iy = 0.42 m4
= 10.36
2
Design shear stress, = 0.34 N/mm
SAFE
= 10.36
2
Design shear stress, = 0.34 N/mm
SAFE
Check for development Length
Sufficient development length should be available for the reinforcement from the critical section.
2 2
𝜏_𝑏𝑑= 1.92 N/mm 𝜎_𝑠= 434.783 N/mm
Ld = 679 mm
The total length available from the critical section = 0.5(L - a)- Cover 450 mm
Provide Ld
Check for bearing stress
2
A1 = 2.25 m 2
2 2
A2 = 0.25 m = 18 N/mm
2
1.82 N/mm SAFE