Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

DESIGN OF ISOLATED FOOTING

Footing F1
Input Load Combination:
Width along x, a 500 mm x-direction
Width along y, b 500 mm y-direction
Grade of concrete,fck = 20 N/mm2 Pu (kN) Mux(kNm) Muy (kNm)
2
Grade of steel, fy = 500 N/mm 454.408 14.7987 14.9945
Clear cover 50 mm P (kN) Mx(kNm) My (kNm)
Safe bearing pressure 150 kN/m2 333.23 9.87 10.00
Loading condition Normal ey = 0.033 m
Safe bearing pressure for given loading 150 kN/m2 ex = 0.033 m
Quick Check
Calculated length 1.49 m Suggested Length 1.5 m (X-dimension)
Calculated width 1.49 m Suggested width 1.5 m (Y-dimension)
Pressure at corner points
at (-0.75,0.75) = 147.87 OK at (0.75,0.75) = 183.41 NOT OK
at (-0.75,-0.75) = 112.79 OK at (0.75,-0.75) = 148.34 OK
Check for development length: Provide Ld Check for bearing pressure: SAFE
Check for X-direction Check for Y-direction
Required d for moment 112.47 mm Required d for moment 112
Provide D 400.00 mm Provide D 400.00
Diameter of bars 12 mm Diameter of bars 12
Calculated Spacing 284 mm Calculated Spacing 284
Provided spacing 150 mm Provided spacing 150
Check for two way shear SAFE Check for two way shear SAFE
Check for one way shear SAFE Check for one way shear SAFE

Calculations
2
Area of footing required, LB 2.22 m
a-b = 0 mm
𝐿^2−(𝑎−𝑏)𝐿−𝐿𝐵=0 Ref. S.N Sinha
L= 1.49 m Provide 1.5 m
B= 1.49 m Provide 1.5 m
Area provided = 2.25 m2
Moment of Inertia about X axix, Ix = 0.42 m4
Moment of Inertia about Y axix, Iy = 0.42 m4

Stress at any point is given by, 𝑝=𝑃/𝐴+𝑀_𝑦/𝐼_𝑥 𝑥+𝑀

At x = -L/2 = -0.75 y = -B/2 = -0.75 p= 112.79 kN/m2 OK


x = L/2 = 0.75 y = -B/2 = -0.75 p= 148.34 kN/m2 OK
x = L/2 = 0.75 y = B/2 = 0.75 p= 183.41 kN/m2 NOT OK
x = -L/2 = -0.75 y = B/2 = 0.75 p= 147.87 kN/m2 OK
Calculation for X-direction

221.81 (Factored upward pressure)


275.12 kN/m2
1.00 m 0.50 m
257.35

Bending moment at critical section 33.65 kN-m/m at face of the column


Reinforcement index 0.133
Minimum depth, d 112 mm
Provide overall depth, D 400 mm approx three times calculated value
Assume diameter of bar 12 mm
Effective depth d 332 mm
0.30528

Ast required 237.252 mm2


Ast minimum 398.4 mm2
Spacing 283.88 mm Provide 150 mm c/c
Area of steel provided 753.98 mm2 and pt = 0.23%
Provide 12 mm dia bars @ 150 mm c/c at bottom (Parallel to X)
Check for two way shear:
Critical Section in two way shear
The critical section for the two way
1
shear occurs at a distance of d/2
0.8
from the face of the column
0.6
a+d = 832 mm
0.4
b+d = 832 mm
0.2
Punching area = 0.69 m2 0
Punching perimeter = 3.328 m -1.00 -0.50 -0.2 0.00 0.50 1.00
-0.4
Factored pressure at corners -0.6
2
at (-0.416,-0.416) = 192.78 kN/m -0.8
2 -1
at (0.416,-0.416) = 222.35 kN/m
2
at (0.416,0.416) = 251.53 kN/m
2
at (-0.416,0.416) = 221.96 kN/m
2
Average factored upward pressure = 222.155 kN/m
Punching shear force = Factored load - factored upward pressure x punching area
300.627 kN
2
Therefore, Nominal punching shear stress, 𝜏_𝑣 = 0.27 N/mm Ref. IS 456: 2000, Cl. 31.6.1
2
Allowable shear stress = 〖𝑘_𝑠𝜏 1.12 N/mm SAFE
Where, ks = 1
𝜏_𝑐= 2
1.12 N/mm
Check for one way shear:
The critical section for one way shear occurs at a distance "d" from the face of the column.
= 0.168 m from edge of the fooring
2
Factored upward stress at that point = 269.15 kN/m
2
Average upward stress 272.135 kN/m
Total shear force along the critical section = 68.5781 kN
2
Nominal shear stress 0.14 N/mm
Percentage of steel, pt 0.23%

= 10.36

2
Design shear stress, = 0.34 N/mm
SAFE

Calculation for Y-direction

222.50 (Factored upward pressure)


275.12 kN/m2
1.00 m 0.50 m
257.58

Bending moment at critical section 33.66 kN-m/m at face of the column


Reinforcement index 0.133
Minimum depth, d 112 mm
Provide overall depth, D 400 mm approx three times calculated value
Assume diameter of bar 12 mm
Effective depth d 332 mm
0.305

Ast required 237.322 mm2


Ast minimum 398.4 mm2
Spacing 283.88 mm Provide 150 mm c/c
Area of steel provided 753.98 mm2 and pt = 0.23%
Provide 12 mm dia bars @ 150 mm c/c at bottom (Parallel to X)
Check for two way shear:
The critical section for the two way Critical Section in two way shear
shear occurs at a distance of d/2 1
from the face of the column 0.8
a+d = 832 mm 0.6
b+d = 832 mm 0.4
Punching area = 0.69 m2 0.2
Punching perimeter = 3.328 m 0
-1.00 -0.50 -0.2 0.00 0.50 1.00

Factored pressure at corners -0.4


2 -0.6
at (-0.416,-0.416) = 192.78 kN/m
2 -0.8
at (0.416,-0.416) = 222.35 kN/m
2 -1
at (0.416,0.416) = 251.53 kN/m
2
at (-0.416,0.416) = 221.96 kN/m
2
Average factored upward pressure = 222.155 kN/m
Punching shear force = Factored load - factored upward pressure x punching area
300.627 kN
2
Therefore, Nominal punching shear stress, 𝜏_𝑣= 0.27 N/mm
2
Allowable shear stress = 〖𝑘_𝑠𝜏 1.12 N/mm SAFE Ref. IS 456: 2000, Cl. 31.6.1
Where, ks = 1
𝜏_𝑐= 2
1.12 N/mm

Check for one way shear:


The critical section for one way shear occurs at a distance "d" from the face of the column.
= 0.168 m from edge of the fooring
2
Factored upward stress at that point = 269.228 kN/m
2
Average upward stress 272.174 kN/m
Total shear force along the critical section = 68.5879 kN
2
Nominal shear stress 0.14 N/mm
Percentage of steel, pt 0.23%

= 10.36

2
Design shear stress, = 0.34 N/mm
SAFE
Check for development Length
Sufficient development length should be available for the reinforcement from the critical section.
2 2
𝜏_𝑏𝑑= 1.92 N/mm 𝜎_𝑠= 434.783 N/mm
Ld = 679 mm
The total length available from the critical section = 0.5(L - a)- Cover 450 mm
Provide Ld
Check for bearing stress
2
A1 = 2.25 m 2
2 2
A2 = 0.25 m = 18 N/mm

2
1.82 N/mm SAFE