1

E-1002
V-1002

R -1001
C-1001
C 2
3

SYN GAS

Fig-1(system 1)

3 E-1001

V-1001
FEED
T -1001
4

Fig-2 (system 2)
For the above system there are following informatiom available:

Design T-1001 E-1001 V-1001 R-1001 V-1002 E-1002 C-1001

Temp 0C 180 200 200 150 120 150 80


Press bar 4 16 7 25 19 20 24

In Fig-1,2 :

- Column diameter (T-1003) : 1500 mm for 45000 ton/year capacity


- Column bottom level (hold up) is about 15 minutes
- Column height is about 55 m. and is insulated with rock wool
40mm Thk.
- L/D in T-1003 is about 24

Stream No 1 2 3 4
Flow (kg/hr) 70000 25000 24000 1000
Phase Two phase Liquid Vapor liquid
process Nbal +propylene Nbal Ibal Ibal
Temp 75 45 75 45

Ibal: iso-butyraldehyde
Nbal: normal butyraldehyide

Requirements:

- recommended location for PSV in both systems


- calculation and sizing of two PSVs, one in system 1 for cooling
failure and another on system 2 for external firing