1 300NB X 4.5mm thk 1. Ovality, Squareness, Straightness, OD & ID not offered because of unavailability of measuring instruments. 2. Requirement of End finish not known. However, observed Plain ends. Requirement to be confirmed. 3. Pipe observed to be having stamping of FE 330 angainst required FE410 as mentioned in QAP. 4. RMTC of 300NB Pipes reviewed observed to be confirming to FE330 against required FE410 as mentioned in QAP. 2 450 X 5.0mm thk 1. Ovality, Squareness, Straightness, OD & ID not offered because of unavailability of measuring instruments. 2. Requirement of End finish not known. However, observed Beveled ends. Requirement to be confirmed. 3. Pipe observed to be having stamping of FE 330 angainst required FE410 as mentioned in QAP. 4. RMTC of 450NB Pipes reviewed observed to be confirming to FE330 against required FE410 as mentioned in QAP. 5. As per RMTC rust preventive applied only on outer surface. Requirement to be confirmed 3 500NB X 5mm thk 1. Ovality, Squareness, Straightness, OD & ID not offered because of unavailability of measuring instruments. 2. Requirement of End finish not known. However, observed Plain ends although in RMTC bevelled end is mentioned. Requirement to be confirmed. 3. As per RMTC rust preventive applied only on outer surface. Requirement to be confirmed 4 40NB Black Medium 1. Observed rust & dust accumulation on pipes. 2. End finish observed to be plain edge. Requirement to be confirmed 3. Straightness & squareness not offered for witness by M/s ADPL on 40NB black pipes due to unavailability of measuring instruments. 5 GI 40NB X 3.25mm thk 1. End finish observed to be threaded (22mm depth). Requirement to be confirmed. 2. Straightness & squareness not offered for witness by M/s ADPL due to unavailability of measuring instruments 3. Thread & wall thickness of not offered for witness by M/s ADPL due to unavailability of measuring instruments. 4. Observed rust stains on threaded portion of the pipes. Note:
1. Total length is 6m and was measured by uncalibrated measuring tape.
2. Surface finish of only accessible portion of pipes could be witnessed due to constraint of stacked condition. 3. All offered pipes except 40NB GI pipes offered without end caps